Enhance SNMP error logging to include:
- Target IP address
- SNMP version (v1/v2c)
- Timeout value in milliseconds
- OID being queried
Before:
[warning] SNMP GET failed for "1.3.6.1.2.1.2.2.1.10.15729368": :timeout
After:
[warning] SNMP GET failed for 192.168.1.1 (v2c, timeout: 5000ms) OID "1.3.6.1.2.1.2.2.1.10.15729368": :timeout
This makes it much easier to diagnose SNMP issues by immediately knowing which
device is timing out and what the network configuration is.
Updated all SNMP operations: GET, WALK, and GET-BULK.
Use Plug.Telemetry's dynamic log level feature to disable logging for
/health requests. This is the proper Phoenix way to exclude specific
endpoints from request logs.
- Add log_level/1 function to endpoint that returns false for /health
- Configure Plug.Telemetry to use dynamic log level
- Remove log: false from router (handled by endpoint now)
This prevents Kubernetes health probe spam in application logs.
When exiting impersonation, now redirects to the superuser's default
organization's equipment list page instead of /admin. Falls back to /orgs
if the superuser has no organizations.
Critical bug fix: fetch_current_scope_for_user and mount_current_scope
were calling Accounts.get_user(nil) when impersonating session flag was
true but superuser_id or target_user_id were nil.
This caused FunctionClauseError crashes for all logged-out users if they
had stale impersonation session data.
Changes:
- Check if both superuser_id and target_user_id exist before calling get_user
- Clear invalid impersonation state if IDs are missing
- Apply fix to both fetch_current_scope_for_user (controllers) and
mount_current_scope (LiveViews)
This ensures graceful handling of corrupted/partial session state.
Changed signed_in_path to redirect users to their default organization's
equipment page instead of the organization list.
Behavior:
- If user has organizations, redirect to first org's equipment page
- First org is determined by most recently joined (membership.inserted_at)
- If user has no organizations, redirect to /orgs to create one
This provides a better UX by landing users directly at their equipment
list instead of requiring an extra click through the org selector.
Security improvements to prevent potential issues:
1. Port Validation (normalize_port):
- Validate port range is 1-65535
- Use Integer.parse instead of String.to_integer to prevent crashes
- Return default port 161 for any invalid input
2. SNMP Test Validation (validate_test_snmp_input):
- Validate IP address format before allowing SNMP tests
- Require non-empty community string
- Prevent network scanning with invalid/missing IPs
- Return clear error messages for validation failures
These changes ensure user input is properly validated and prevent:
- Integer overflow/underflow with ports
- Process crashes from invalid input
- Unauthorized network scanning via SNMP test feature
- SNMP requests with missing credentials
Two issues were preventing impersonation from working correctly:
1. Templates were not passing current_scope to Layouts.authenticated,
so the impersonation banner never displayed.
2. fetch_current_scope_for_user was looking up the user from the
session token, which always pointed to the superuser. This caused
the superuser to see their own organizations and equipment instead
of the impersonated user's data.
Changes:
- Pass current_scope={@current_scope} to all Layouts.authenticated calls
- Store target_user_id in session during impersonation
- Fetch target user directly from database using target_user_id
- Update both fetch_current_scope_for_user (for controllers) and
mount_current_scope (for LiveViews) to properly handle impersonation
- Clean up target_user_id from session when impersonation ends
Now when a superuser impersonates a user, they correctly see:
- The impersonation banner at the top with exit link
- The target user's organizations and equipment
- All data scoped to the impersonated user
Extracted SNMP configuration extraction and connection testing
into separate helper functions, reducing cyclomatic complexity
from 11 to ~5.
- extract_snmp_config/1: Consolidates form data and params
- normalize_port/1: Handles port type conversion
- test_snmp_connection/1: Performs test and formats result
This makes the handle_event callback simpler and each concern
easier to test independently.
Refactored three highly complex functions to improve code maintainability:
1. PollerWorker.detect_sensor_changes (complexity 33 -> ~9):
- Extracted threshold checking logic into separate functions
- Split event creation into focused helper functions
- Reduced nesting by using pipe operator pattern
2. PollerWorker.detect_and_log_changes (complexity 16 -> ~5):
- Created separate functions for each interface change type
- Extracted event building logic into dedicated functions
- Improved readability with clear function names
3. EquipmentLive.Show.format_duration (complexity 13 -> ~5):
- Extracted time unit conversion into separate functions
- Simplified pluralization logic with pattern matching
- Reduced nested conditionals
These changes make the code easier to test, maintain, and understand
while preserving all existing functionality.
The poller was re-logging SNMP errors from Client.get as warnings,
even though the client now logs them at debug level. Updated the
poller to also use debug level for expected errors like :no_such_object.
This completes the fix to reduce SNMP logging noise for devices
that don't support certain MIB objects.
The admin layout was incorrectly defined as a separate .html.heex file
using @inner_content. Phoenix components should use render_slot(@inner_block).
Moved admin layout definition into layouts.ex as a proper function
component, matching the pattern used by app/1 and authenticated/1 layouts.
Changed SNMP Client to use debug level for expected errors
(:no_such_object, :no_such_instance, :end_of_mib_view) and
only use warning level for actual communication errors.
This prevents log spam when polling interfaces that don't
support certain MIB objects, which is normal behavior.
Replace raw HTML form with Phoenix .link helper using method="delete" to properly handle CSRF token in LiveView context. This fixes the UndefinedFunctionError when accessing /admin route.
Replace expensive length/1 comparisons with direct list comparisons or Enum.empty?/1 checks (13 instances in source code and tests). Add module aliases for Phoenix.HTML.Form and Towerops.Accounts.Scope to reduce nested module references.
Changes:
- Replace length(list) > 0 with list != [] or refute Enum.empty?(list)
- Add Phoenix.HTML.Form alias in CoreComponents
- Add Towerops.Accounts.Scope alias in ConnCase test helper
This eliminates all credo warnings and software design suggestions.
Implement comprehensive admin interface allowing designated superusers to view all users and organizations, impersonate users for debugging, and perform administrative operations. All superuser actions are tracked in audit logs for compliance.
Features:
- Superuser authentication with dedicated admin routes at /admin
- User impersonation with session state preservation
- Admin dashboard with system statistics
- User and organization management interfaces
- Comprehensive audit logging with IP tracking
- Visual impersonation banner with exit capability
- Security controls preventing self-impersonation and superuser-to-superuser impersonation
Database:
- Add is_superuser boolean field to users table
- Create audit_logs table for tracking sensitive operations
- Set graham@mcintire.me as initial superuser
- Prefix unused alert variables with underscore
- Remove unused test_env?/0 function
All warnings resolved, compilation clean with --warnings-as-errors
SNMPKit library logs complete SNMP messages at debug level, which
includes the community string (credential). Setting log level to :info
prevents these debug messages from appearing in development logs.
Production and test environments already use :info and :warning levels.
- Display storage sensors as a list similar to temperature/voltage
- Show individual disk/partition usage with current values
- Link to graph view from sensor names
- More consistent with other sensor displays
Based on MikroTik MIB analysis, added discovery for:
Device Information:
- Board name, display name, build time
Health Sensors - Voltages:
- Core voltage, 3.3V/5V/12V supplies, input voltage
Health Sensors - Temperatures:
- Sensor chip, CPU, board, system, processor temperatures
Health Sensors - Power & Cooling:
- Power consumption (W), current draw (mA)
- Processor frequency (MHz)
- Active fan status, fan speeds (RPM)
- Power supply state, backup PSU state
POE Monitoring (per port):
- Voltage, current, power consumption
- Automatically discovers all POE-enabled ports
Optical/SFP Monitoring (per interface):
- Temperature, voltage
- TX/RX optical power levels (dBm)
- Supports fiber transceivers and SFP modules
All sensors include proper units, divisors, and descriptive names.
- Add new event types: sensor_threshold_warning, sensor_threshold_critical, sensor_threshold_normal, sensor_value_spike, sensor_value_drop
- Implement sensor change detection in PollerWorker
- Track threshold violations (warning/critical high/low)
- Detect value spikes/drops for percentage sensors (30% change)
- Track return to normal from threshold violations
- Store threshold config in sensor metadata
- Update sensor last_value and last_checked_at on each poll
- Broadcast sensor events via PubSub for real-time logging
- Add EventLogger tests for PubSub event system
- Update navigation tests to match current UI patterns
- Fix alert notifier from address expectations
- Update site and equipment tests for relocated delete buttons
- Remove obsolete tests for removed UI elements (Recent Checks, monitoring widgets)
- All 254 tests now passing
- Detect when interface speed changes from null to a value
- Detect when MAC address changes from null to a value
- Log initial discoveries with "info" severity
- Differentiate between initial discovery and actual changes
- Show "detected" message for initial values
- Show "changed from X to Y" message for actual changes
- Replace grid of sensor cards with table format matching device info
- Display sensor name on left, value on right
- Make sensor names clickable links to graph detail page
- Remove generic "Sensors" section from overview
- Cleaner, more scannable layout for temperature and voltage sensors
- Create GraphLive.Show for detailed sensor graph visualization
- Add route for /equipment/:id/graph/:sensor_type endpoint
- Make all chart headers clickable with navigation to detail view
- Implement date range selector (1h, 6h, 12h, 24h, 7d, 30d)
- Fix chart rendering by destroying and recreating on data updates
- Fix duplicate data loading in LiveView event handlers
- Fix MikroTik profile typing warning for entity sensor discovery
- Add Chart.js integration for interactive sensor graphs
- Add processor, memory, storage, temperature, and voltage charts showing 24 hours of data
- Fix device information box to use natural height instead of stretching
- Update MikroTik profile to discover ENTITY-SENSOR-MIB sensors
- Support multiple sensor types per chart (celsius/temperature, volts/voltage)
- Use 24-hour time format in chart tooltips and x-axis labels
- Support auto-scaling y-axis for non-percentage metrics