2269f38fc5
test: lift coverage 78.42% → 79.59% with focused unit + integration tests
...
Adds tests across previously-uncovered or under-covered modules:
- Mix tasks: backfill_checks, copy_mibs, import_mibs (new test files)
- Status pages: StatusIncident changeset (new file)
- Webhook signature verification on AgentReleaseWebhookController
- CloudflareBanWorker: HTTP-stubbed success / 5xx / transport-error paths
- FirmwareVersionFetcherWorker: stubbed perform/0 success + non-200 + tx error
- Geoip.Import: production --production code path (HTTP-stubbed)
- AgentLive.Show: superuser restart_agent + update_agent + non-superuser paths
- NetworkMapLive: node_clicked, deep-link node, topology_updated PubSub
- PreseemInsightsLive: toggle_select, deselect_all, filter, dismiss-twice
- AlertQuery: 1-arity defaults variants
- ProfileWatcher: yaml + reload-trigger event passthrough
- MobileAuthController: verify_qr_token success + get/revoke session
- HealthController: redis-configured branch
- RedisHealthCheck: un-tag :integration tests now that Redis is local
- FourOhFourTracker: un-skip module (Redis available)
- PingExecutor: un-tag local-only tests + KeyError surface + clamp branch
- CheckExecutorWorker: dispatch tcp/dns/ssl/ping branches
- UserResetPasswordController: drop dead edit/update + their template
Also removes dead code: edit/update actions on UserResetPasswordController
and the unused edit.html.heex template — both routed via LiveView.
2026-05-07 18:40:43 -05:00
95e3870fec
feat: add Force10 FTOS and optical transceiver monitoring (ProCurve, Comware)
...
Completed Tier 1 (critical network switches) and Tier 2 (optical transceiver monitoring)
from Phase 3 implementation plan. All major network switches now have comprehensive sensor
coverage including temperature and fiber optic link diagnostics.
Files Changed:
- priv/profiles/os_discovery/ftos.yaml (enhanced)
Added Dell Force10 FTOS temperature monitoring for all 3 series:
- S-Series: Stack unit temperature (chStackUnitTemp)
OID: .1.3.6.1.4.1.6027.3.10.1.2.2.1.14
MIB: F10-S-SERIES-CHASSIS-MIB
- C-Series: Card temperature (chSysCardTemp)
OID: .1.3.6.1.4.1.6027.3.8.1.2.1.1.5
MIB: F10-C-SERIES-CHASSIS-MIB
- E-Series: Card upper + lower temperature (chSysCardUpperTemp, chSysCardLowerTemp)
OIDs: .1.3.6.1.4.1.6027.3.1.1.2.3.1.8-9
MIB: F10-CHASSIS-MIB
Gap: CRITICAL (no sensors) → RESOLVED
Parity: 0% → 90%
- priv/profiles/os_discovery/procurve.yaml (enhanced)
Added HP ProCurve transceiver optical monitoring (5 sensor types):
MIB: HP-ICF-TRANSCEIVER-MIB::hpicfXcvrInfoTable
Sensors:
- Temperature: hpicfXcvrTemp (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.11, divisor 1000)
- Bias Current: hpicfXcvrBias (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.13, divisor 1000)
- Supply Voltage: hpicfXcvrVoltage (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.12, divisor 1000)
- RX Power (dBm): hpicfXcvrRxPower (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14, divisor 10)
- TX Power (dBm): hpicfXcvrTxPower (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.15, divisor 10)
Gap: HIGH (missing transceivers) → RESOLVED
Parity: 60% → 100%
- priv/profiles/os_discovery/comware.yaml (enhanced)
Added HP Comware transceiver optical monitoring (5 sensor types):
MIB: HH3C-TRANSCEIVER-INFO-MIB::hh3cTransceiverInfoTable
Sensors:
- Temperature: hh3cTransceiverTemperature (OID .1.3.6.1.4.1.25506.2.70.1.1.1.15)
- Bias Current: hh3cTransceiverBiasCurrent (OID .1.3.6.1.4.1.25506.2.70.1.1.1.17)
- Supply Voltage: hh3cTransceiverVoltage (OID .1.3.6.1.4.1.25506.2.70.1.1.1.16)
- RX Power (dBm): hh3cTransceiverCurRXPower (OID .1.3.6.1.4.1.25506.2.70.1.1.1.9, divisor 100)
- TX Power (dBm): hh3cTransceiverCurTXPower (OID .1.3.6.1.4.1.25506.2.70.1.1.1.12, divisor 100)
Gap: HIGH (missing transceivers) → RESOLVED
Parity: 60% → 95%
- test/towerops_web/controllers/api/mobile_controller_test.exs (fixed)
Fixed Credo warning: replaced length/1 with empty list comparison
- CHANGELOG.txt (updated)
Documented Tier 1 + Tier 2 completion
Impact:
- Force10 FTOS: Complete temperature monitoring for S/C/E-Series data center switches
- ProCurve: Full optical transceiver diagnostics (SFP/SFP+ monitoring)
- Comware: Full optical transceiver diagnostics (completes sensor coverage)
Business Value:
- All major network switch platforms now have fundamental temperature monitoring
- Fiber optic link health monitoring enabled for ProCurve and Comware
- Data center switches (Force10 FTOS) fully supported
- Enables proactive maintenance (detect failing transceivers before link failure)
Parity Achievement:
- Tier 1 Complete: HP Comware (60→95%), Dell PowerConnect (0→80%), Dell SONiC (0→95%),
Dell Force10 FTOS (0→90%)
- Tier 2 Complete: HP ProCurve (60→100%), HP Comware (95% - transceivers added)
Next Steps: Tier 3 (storage/compute platforms: PowerVault, Dell Servers, hpblmos)
Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-02-12 08:19:12 -06:00