- Add real-time updates with 10-second refresh and PubSub integration
- Implement pure SVG charts: response time sparkline and uptime gauge
- Create compact dashboard layout with status cards, metrics, and graphs
- Add relative time display (e.g., '5s ago') for last check
- Redesign SNMP data display: compact device info, sensors grid, interfaces table
- Calculate and display uptime percentage and average response time
- Update tests to match new compact layout
- Explicitly discard return value from trigger_check call
- The return value is not needed for this fire-and-forget operation
- Resolves unmatched_return warning at line 58
- Explicitly discard return value from Endpoint.broadcast call
- Broadcast is fire-and-forget, return value not needed
- Resolves unmatched_return warning at line 54
- Create changeset before Multi pipeline for better type inference
- Pass changeset directly to Multi.insert instead of using function form
- Resolves call_without_opaque warning at line 97
- Replace catch-all pattern with explicit :unknown status handling
- Makes status transitions more explicit and type-safe
- Resolves pattern_match_cov warning at line 174
- Organization names can now be freely duplicated
- Slugs are generated as random 8-character lowercase alphanumeric IDs
- Provides ~218 trillion possible combinations
- Updated tests to not rely on name-based slug patterns
- Update LiveView tests to match actual redirect behavior
- Fix equipment and site form redirect test expectations
- Update organization tests to reflect slug-based uniqueness
- All datetime truncation fixes for Ecto :utc_datetime fields
- Add active_page attribute to authenticated layout
- Update nav_link component to show active state with border and text styling
- Update all LiveView templates to pass active_page parameter
- Fix datetime truncation issues in tests and schemas for :utc_datetime fields
- Fix dashboard test assertions for equipment status text
Only equipment_down alerts should be counted as "active alerts that need attention".
Equipment_up alerts are informational recovery notifications and don't require action.
- Add authenticated layout with navigation to equipment/site forms and show pages
- Remove remaining DaisyUI classes from detail pages
- Update buttons to use proper component variants
- Ensure consistent styling across all authenticated pages
- Remove default Phoenix branding and create custom layouts
- Replace DaisyUI classes with custom Tailwind components throughout
- Add authenticated layout with navigation bar for organization pages
- Redesign all core components (buttons, forms, tables, alerts)
- Make dashboard stat cards clickable to navigate to respective pages
- Update alert acknowledge button to only show for equipment down alerts
- Add consistent dark mode support across all pages
- Implement modern design with zinc color palette and improved spacing
Monitoring Infrastructure:
- lib/towerops/monitoring/ping.ex - OS-agnostic ping functionality that works on macOS, Linux, and Windows
- lib/towerops/monitoring/equipment_monitor.ex - GenServer that monitors individual equipment at configurable intervals
- lib/towerops/monitoring/supervisor.ex - DynamicSupervisor with Registry for managing monitor workers
- lib/towerops/monitoring.ex - Context for creating and querying monitoring checks
Database:
- monitoring_checks table stores historical ping results with status, response time, and timestamps
- Indexed on (equipment_id, checked_at) for efficient querying
Real-Time Updates:
- PubSub broadcasting on equipment:#{id} topic when status changes
- Equipment show page subscribes to updates and refreshes automatically
- Manual "Check Now" button to trigger immediate checks
Application Integration:
- Monitoring.Supervisor added to application supervision tree
- All monitored equipment starts monitoring automatically on app startup
- Recent checks displayed in Equipment show page
How It Works
1. On application start, a monitor GenServer is spawned for each equipment with monitoring_enabled: true
2. Each monitor pings its equipment at the configured interval (default 5 minutes)
3. Results are saved to monitoring_checks table
4. Equipment status is updated if it changes (up ↔ down)
5. Status changes are broadcast via PubSub to all connected LiveViews
6. The Equipment show page updates in real-time when status changes