Proxmox: node1-3 → 10.0.19.101-103 Talos cp1-3 → 10.0.19.1-3, workers → 10.0.19.4-6 K8s endpoint → VIP https://10.0.19.10:6443 Ansible: prom → 10.0.19.31, db → 10.0.19.30 Talos: added VIP block to controlplane.yaml base config Promtail: Loki URL → 10.0.19.31 Docs: all references updated, talos4 removed
3.9 KiB
3.9 KiB
Ceph CSI RBD Driver for Talos Cluster
This directory contains manifests for deploying the Ceph CSI RBD driver to use Proxmox Ceph storage directly in the Talos Kubernetes cluster.
Configuration
- Ceph Cluster FSID:
7e968d44-61b4-4342-8318-2e8e48808e68 - Ceph Monitors: 10.0.19.101:6789, 10.0.19.102:6789, 10.0.19.103:6789
- Ceph Pool: kubernetes
- Ceph User: client.kubernetes
- StorageClass: ceph-rbd (default)
Deployment
All manifests have been applied to the cluster:
cd /Users/graham/dev/infra/cluster/ceph-csi
./deploy.sh
Deployed Components
- Namespace: ceph-csi-rbd (with privileged pod security)
- ConfigMaps: Ceph cluster configuration and encryption KMS config
- Secret: Ceph credentials for client.kubernetes user
- RBAC: ServiceAccounts, ClusterRoles, and bindings for provisioner and plugin
- Provisioner: 3-replica deployment for volume provisioning
- Plugin: DaemonSet running on all nodes (including control plane)
- CSIDriver: CSI driver registration
- StorageClass: ceph-rbd (default, WaitForFirstConsumer binding mode)
Status
# Check all pods
kubectl get pods -n ceph-csi-rbd
# Check StorageClass
kubectl get storageclass ceph-rbd
# Check CSI nodes
kubectl get csinodes
Topology Configuration
The Ceph CSI driver requires topology configuration for proper volume scheduling. This has been configured as follows:
Solution Applied:
- Added
--domainlabels=topology.kubernetes.io/zoneto CSI node plugin - Labeled all nodes with
topology.kubernetes.io/zone=default - CSI driver automatically creates
topology.rbd.csi.ceph.com/zone=defaultlabels - Restarted provisioner pods to pick up updated CSINode topology information
Result: PVCs now provision successfully and volumes are created in the Ceph kubernetes pool.
Verification:
# Check topology labels on nodes
kubectl get nodes --show-labels | grep topology
# Check CSINode topology keys
kubectl get csinode -o yaml | grep topologyKeys -A 2
# List RBD images in Ceph
ssh root@10.0.19.101 "rbd ls -p kubernetes"
Testing
A test PVC and pod are provided:
kubectl apply -f test-pvc.yaml
# Check PVC status
kubectl get pvc ceph-rbd-test
# Check pod status
kubectl get pod ceph-rbd-test-pod
# Clean up test
kubectl delete -f test-pvc.yaml
Ceph Pool Management
# SSH to any Proxmox node
ssh root@10.0.19.101
# List pools
ceph osd pool ls
# Check pool usage
ceph df
# List RBD images in kubernetes pool
rbd ls -p kubernetes
# Get image info
rbd info -p kubernetes <image-name>
Troubleshooting
Check Provisioner Logs
kubectl logs -n ceph-csi-rbd -l app=csi-rbdplugin-provisioner -c csi-provisioner --tail=50
kubectl logs -n ceph-csi-rbd -l app=csi-rbdplugin-provisioner -c csi-rbdplugin --tail=50
Check Plugin Logs
kubectl logs -n ceph-csi-rbd -l app=csi-rbdplugin -c csi-rbdplugin --tail=50
Restart Provisioner
kubectl delete pods -n ceph-csi-rbd -l app=csi-rbdplugin-provisioner
Check Ceph Health
ssh root@10.0.19.101 "ceph health detail"
Files
00-namespace.yaml- Namespace definition01-configmap.yaml- Ceph cluster and encryption configuration02-secret.yaml- Ceph client credentials03-rbac-provisioner.yaml- RBAC for provisioner04-rbac-plugin.yaml- RBAC for node plugin05-provisioner.yaml- Provisioner deployment06-plugin.yaml- Plugin DaemonSet (with control plane tolerations)07-csidriver.yaml- CSI driver registration08-storageclass.yaml- StorageClass definitiondeploy.sh- Deployment scripttest-pvc.yaml- Test PVC and pod
Alternative: Longhorn
If Ceph CSI continues to have issues, consider deploying Longhorn instead:
kubectl apply -f https://raw.githubusercontent.com/longhorn/longhorn/v1.7.2/deploy/longhorn.yaml