- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
177 lines
5.8 KiB
Text
177 lines
5.8 KiB
Text
-- %DNP% $Id: ERICSSON-ROUTER-TC.my,v 1.1.2.8.252.3 2011/02/22 17:26:18 thatcher Exp $
|
|
-- %DNP% $Source: /cvsroot/pkt/sw/se/xc/bsd/config/snmp/mibs/Attic/ERICSSON-ROUTER-TC.my,v $
|
|
-- *****************************************************************
|
|
-- ERICSSON-ROUTER-TC Textual Convention MIB
|
|
--
|
|
-- Copyright (c) 2000, 2002-2009, 2011, 2014, 2015, 2017 Ericsson AB
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
|
|
ERICSSON-ROUTER-TC DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
Integer32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
|
|
eriRouterModules
|
|
FROM ERICSSON-ROUTER-SMI;
|
|
|
|
|
|
eriRouterTC MODULE-IDENTITY
|
|
LAST-UPDATED "201707281800Z" -- Jul 28, 2017
|
|
ORGANIZATION "Ericsson AB."
|
|
CONTACT-INFO
|
|
" Ericsson AB.
|
|
|
|
Postal: 100 Headquarters Dr
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Phone: +1 408 750 5000
|
|
Fax: +1 408 750 5599
|
|
"
|
|
DESCRIPTION
|
|
"Defines common textual conventions used in ERICSSON-ROUTER mib
|
|
modules."
|
|
|
|
REVISION "201707281800Z" -- Jul 28, 2017
|
|
DESCRIPTION
|
|
"Updated the description of textual convention: EriRouterCircuitHandle.
|
|
The circuit handler is used internally and not necessary to export the
|
|
internal structure to users."
|
|
|
|
REVISION "201501141800Z" -- Jan 14, 2015
|
|
DESCRIPTION
|
|
"Updated RBN/rbn/Rbn as ERICSSON-ROUTER/eriRouter/EriRouter
|
|
to migrate RBN MIB to ERICSSON MIB."
|
|
|
|
REVISION "201407191700Z" -- July 19, 2014
|
|
DESCRIPTION
|
|
"Added new textual convention: EriRouterSubscriberState."
|
|
|
|
REVISION "201101191800Z" -- Jan 19, 2011
|
|
DESCRIPTION
|
|
"Update CONTACT-INFO & ORGANIZATION. "
|
|
|
|
REVISION "200910201700Z" -- Oct 20, 2009
|
|
DESCRIPTION
|
|
"Added new textual convention: EriRouterUnsigned64 for read-write
|
|
capable 64 bit integer value."
|
|
|
|
REVISION "200406191700Z" -- June 19, 2004
|
|
DESCRIPTION
|
|
"Added new textual convention: EriRouterPortMediumType. Correct
|
|
warnings given by smilint."
|
|
|
|
REVISION "200303171700Z" -- March 17, 2003
|
|
DESCRIPTION
|
|
"Added new textual convention: EriRouterVidOrUntagged."
|
|
|
|
REVISION "200211110000Z" -- November 11, 2002
|
|
DESCRIPTION
|
|
"Moved definitions of EriRouterSlot and EriRouterPort from ERICSSON-ROUTER-PVC-MIB.
|
|
Updated range on EriRouterSlot and EriRouterPort."
|
|
|
|
REVISION "200206260000Z" -- June 26, 2002
|
|
DESCRIPTION
|
|
"Updated CONTACT-INFO. Added new textual conventions:
|
|
EriRouterKBytes and EriRouterPercentage."
|
|
|
|
REVISION "200007140000Z" -- July 14, 2000
|
|
DESCRIPTION
|
|
"Initial version."
|
|
::= { eriRouterModules 2 }
|
|
|
|
|
|
EriRouterCircuitHandle ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "1d:1d:2x-2x-2x"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for individual circuits."
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
|
|
EriRouterKBytes ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage size, expressed in units of 1024 bytes."
|
|
SYNTAX Integer32 (0..2147483647)
|
|
|
|
EriRouterPercentage ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d%"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Textual Convention describes an object that stores
|
|
a whole integer percentage value."
|
|
SYNTAX Integer32 (0..100)
|
|
|
|
EriRouterSlot ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis slot number. This is the physical slot
|
|
number as reported in the CLI command 'show hardware'
|
|
on SMS and the CLI command 'show port' on SE."
|
|
SYNTAX Unsigned32 (0..255)
|
|
|
|
EriRouterPort ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis port number. This is the physical port
|
|
number as reported in the CLI command 'show hardware'
|
|
on SMS and the CLI command 'show port' on SE."
|
|
SYNTAX Unsigned32 (0..255)
|
|
|
|
EriRouterVidOrUntagged ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The twelve-bit VLAN Identifer (VID) used to uniquely
|
|
identify the VLAN to which the frame belongs. The VID is
|
|
encoded as an unsigned binary number. An untagged frame
|
|
does not carry any identification of the VLAN to which it
|
|
belongs and is designated with a value of 4096."
|
|
SYNTAX Integer32 (1..4096)
|
|
|
|
EriRouterPortMediumType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Medium type of NAS port."
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
dsl(11),
|
|
cable(12),
|
|
wireless(13),
|
|
satellite(14)
|
|
}
|
|
|
|
EriRouterUnsigned64 ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "8d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unsigned 64 bit integer value is represented as an
|
|
OCTET STRING. This allows an unsigned integer value in
|
|
the range 0..18446744073709551615.
|
|
|
|
The octets are ordered with the first octet containing
|
|
the highest ordered bits of the integer and the 8th octet
|
|
containing the lowest ordered bits, corresponding to
|
|
network byte order."
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
|
|
EriRouterSubscriberState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of subscriber session."
|
|
SYNTAX INTEGER {
|
|
up(9),
|
|
standby-up(13)
|
|
}
|
|
|
|
END
|