-- This module defines enterprise MIBs for Virtual Systems
--
-- Copyright (c) 1999-2004, Juniper Networks, Inc.
-- All rights reserved.
NETSCREEN-VSYS-MIB DEFINITIONS ::= BEGIN
IMPORTS
netscreenVsys
FROM NETSCREEN-SMI
Integer32, MODULE-IDENTITY, OBJECT-TYPE
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
;
netscreenVsysMibModule MODULE-IDENTITY
LAST-UPDATED "200405032022Z" -- May 03, 2004
ORGANIZATION
"Juniper Networks, Inc."
CONTACT-INFO
"Customer Support
1194 North Mathilda Avenue
Sunnyvale, California 94089-1206
USA
Tel: 1-800-638-8296
E-mail: customerservice@juniper.net
HTTP://www.juniper.net"
DESCRIPTION
"This module defines the object that are use to monitor all the
virtual systems"
REVISION "200405030000Z" -- May 03, 2004
DESCRIPTION
"Modified copyright and contact information"
REVISION "200403030000Z" -- March 03, 2004
DESCRIPTION
"Converted to SMIv2 by Longview Software"
REVISION "200311130000Z" -- November 13, 2003
DESCRIPTION
"Correct spelling mistake"
REVISION "200109280000Z" -- September 28, 2001
DESCRIPTION
"no comment"
REVISION "200005080000Z" -- May 08, 2000
DESCRIPTION
"Creation Date"
::= { netscreenVsys 0 }
NsVsysCfgEntry ::= SEQUENCE
{
nsVsysCfgId Integer32,
nsVsysCfgName DisplayString
}
nsVsysCfg OBJECT IDENTIFIER ::= { netscreenVsys 1 }
nsVsysCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF NsVsysCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"NetScreen-500, NetScreen-1000 and above series support virtual
system. This table collects the vsys configuration in NetScreen
device."
::= { nsVsysCfg 1 }
nsVsysCfgEntry OBJECT-TYPE
SYNTAX NsVsysCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in the table holds a set of configuration
parameters associated with an instance of virtual system."
INDEX
{ nsVsysCfgId }
::= { nsVsysCfgTable 1 }
nsVsysCfgId OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique ID for each virtual system."
::= { nsVsysCfgEntry 1 }
nsVsysCfgName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"virtual system name."
::= { nsVsysCfgEntry 2 }
END