RAY-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, IpAddress, Gauge
FROM RFC1155-SMI
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Unsigned32, TimeTicks, Counter32, Gauge32, Integer32, Counter64
FROM SNMPv2-SMI
DateAndTime, TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
mib-2 FROM SNMPv2-SMI
snmpTraps
FROM SNMPv2-MIB;
ray MODULE-IDENTITY
LAST-UPDATED "201610040000Z"
ORGANIZATION "Racom s.r.o"
CONTACT-INFO
"Racom s.r.o
Mirova 1283
592 31 Nove Mesto na Morave
Czech Republic
Tel: +420 565 659 511
Fax: +420 565 659 512
E-mail: racom@racom.eu"
DESCRIPTION "The MIB module defines management objects for RAy product series. Revision 201610040000Z."
REVISION "201610040000Z"
DESCRIPTION "Latest version of this MIB module"
::= { racom 1 }
DisplayString ::= OCTET STRING
PhysAddress ::= OCTET STRING
ServiceState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "System service or device state."
SYNTAX INTEGER {
na (0), -- service/device state not available
up (1), -- service is running or device is up
down (2) -- service is not running or device is down
}
AlarmState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Alarm status."
SYNTAX INTEGER {
na (0), -- alarm state not available
up (1), -- alarm up
down (2), -- alarm down
ack (3) -- alarm up and acknowledged
}
OptionSetting ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Setting of some options."
SYNTAX INTEGER {
na (0),
on (1),
off (2)
}
ModulationList ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Radio channel modulations numerical list"
SYNTAX INTEGER {
na (0),
qpsk (1),
qam16 (2),
qam32 (3),
qam64 (4),
qam128 (5),
qam256 (6)
}
racom OBJECT IDENTIFIER ::= { enterprises 33555 }
station OBJECT IDENTIFIER ::= {ray 1}
interface OBJECT IDENTIFIER ::= {ray 2}
statistic OBJECT IDENTIFIER ::= {ray 3}
rayTraps OBJECT IDENTIFIER ::= {ray 10}
ray2Traps OBJECT IDENTIFIER ::= {ray 11}
-- station MIB
product OBJECT IDENTIFIER ::= {station 1}
info OBJECT IDENTIFIER ::= {station 2}
status OBJECT IDENTIFIER ::= {station 3}
chassis OBJECT IDENTIFIER ::= {station 4}
system OBJECT IDENTIFIER ::= {station 5}
access OBJECT IDENTIFIER ::= {station 6}
authorization OBJECT IDENTIFIER ::= {station 7}
alarm OBJECT IDENTIFIER ::= {station 8}
-- product MIB
productName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Product name."
::= { product 1 }
serialNumber OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Product serial number."
::= { product 2 }
unitType OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Station type (L or H) and number of the Ethernet ports (1 or 2)."
::= { product 3 }
-- info MIB
deviceName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Station name."
::= { info 1 }
swVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Firmware version."
::= { info 2 }
swVerRadio OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio firmware version."
::= { info 3 }
-- status mib
systemStatus OBJECT-TYPE
SYNTAX INTEGER {
na (0),
ok (1),
warning (2),
alarm (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Unit status."
::= { status 1 }
lineStatus OBJECT-TYPE
SYNTAX INTEGER {
na (0),
ok (1),
analyzer (2),
connecting (3),
searching (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio link status. Supported by RAy10 only."
::= { status 2 }
peerNumber OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Peer station serial number."
::= { status 3 }
rfPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
na (0),
ok (1),
fail (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RF Power amplifier OK/Failure."
::= { status 4 }
searchModeDisabled OBJECT-TYPE
SYNTAX OptionSetting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Search mode disabled on/off. Supported by RAy10 only."
::= { status 5 }
ethPeer OBJECT-TYPE
SYNTAX ServiceState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Peer station user Ethernet link status. Not supported by RAy2."
::= { status 6 }
securePeerMode OBJECT-TYPE
SYNTAX OptionSetting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Secure peer mode. Not supported by RAy10."
::= { status 7 }
lineStatusII OBJECT-TYPE
SYNTAX INTEGER {
na (0),
setup (1),
single (2),
connecting (3),
authorizing (4),
ok (5),
analyzer (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio link status. Not supported by RAy10."
::= { status 8 }
eth1Link OBJECT-TYPE
SYNTAX ServiceState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet 1 link status. Supported by RAy2 only."
::= { status 9 }
eth2Link OBJECT-TYPE
SYNTAX ServiceState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet 2 link status. Supported by RAy2 only."
::= { status 10 }
-- chassis mib
temperatureModem OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem temperature in hundredths of Celsius (C)."
::= { chassis 1 }
temperatureRadio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio temperature in hundredths of Celsius (C)."
::= { chassis 2}
voltageUnit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power supply voltage in tenths of Volts (V)."
::= { chassis 3 }
voltageSource OBJECT-TYPE
SYNTAX INTEGER {
na (0),
aux (1),
poe (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Source of supply voltage. Supported by RAy2 only."
::= { chassis 4 }
-- system mib
useCpu OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System use CPU in %."
::= { system 1 }
useMemory OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System use memory in %."
::= { system 2 }
useLogStorage OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Use storage for log in %."
::= { system 3 }
-- access mib
sshd OBJECT-TYPE
SYNTAX INTEGER {
on (1),
onlykey (2),
off (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Management interface: SSH."
::= { access 1 }
telnetd OBJECT-TYPE
SYNTAX OptionSetting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Management interface: Telnet."
::= { access 2 }
httpd OBJECT-TYPE
SYNTAX OptionSetting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Management interface: HTTP."
::= { access 3 }
ip OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Management interface: IP address."
::= { access 4 }
mac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Management interface: MAC address."
::= { access 5 }
managementVlan OBJECT-TYPE
SYNTAX OptionSetting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Management interface: VLAN on/off."
::= { access 6 }
managementVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Management interface: VLAN ID."
::= { access 7 }
wifiHAP OBJECT-TYPE
SYNTAX OptionSetting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Management interface: WiFi Host Access Point."
::= { access 8 }
-- authorization mib
keyTable OBJECT-TYPE
SYNTAX SEQUENCE OF KeyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "List of product key entries. Supported by RAy10 only."
::= { authorization 1 }
keyEntry OBJECT-TYPE
SYNTAX KeyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Product key entry. Supported by RAy10 only."
INDEX { keyName }
::= { keyTable 1 }
KeyEntry ::=
SEQUENCE {
keyName DisplayString
}
keyName OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Product key name. Supported by RAy10 only."
::= { keyEntry 1 }
-- alarm mib
alarmTemperature OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature alarm state. Supported by RAy2 only."
::= { alarm 1 }
alarmVoltageLow OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Low voltage alarm state. Supported by RAy2 only."
::= { alarm 2 }
alarmVoltageHigh OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "High voltage alarm state. Supported by RAy2 only."
::= { alarm 3 }
alarmRss OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RSS alarm state. Supported by RAy2 only."
::= { alarm 4 }
alarmSnr OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SNR alarm state. Supported by RAy2 only."
::= { alarm 5 }
alarmBer OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "BER alarm state. Supported by RAy2 only."
::= { alarm 6 }
alarmPeerDisconnected OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Peer disconnect alarm state. Supported by RAy2 only."
::= { alarm 7 }
alarmEth1Down OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet 1 Link Down alarm state. Supported by RAy2 only."
::= { alarm 8 }
alarmEth2Down OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet 2 Link Down alarm state. Supported by RAy2 only."
::= { alarm 9 }
alarmRfPowerFail OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RF Power Fail alarm state. Supported by RAy2 only."
::= { alarm 10 }
alarmNetBitrate OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Air Speed below Limit alarm state. Supported by RAy2 only."
::= { alarm 11 }
alarmWifiOn OBJECT-TYPE
SYNTAX AlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "WiFi Host Access Oint on. Supported by RAy2 only."
::= { alarm 12 }
-- interface mib
ifRadio OBJECT IDENTIFIER ::= {interface 1}
ifEth OBJECT IDENTIFIER ::= {interface 2}
-- radio mib
rxChannel OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Receiver channel ID."
::= { ifRadio 1 }
txChannel OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Transceiver channel ID."
::= { ifRadio 2 }
rxFreq OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Receiver frequency in kHz."
::= { ifRadio 3 }
txFreq OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Transceiver frequency in kHz."
::= { ifRadio 4 }
rxModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Rx modulation text ID."
::= { ifRadio 5 }
txModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Tx modulation text ID."
::= { ifRadio 6 }
rxModulationIndex OBJECT-TYPE
SYNTAX ModulationList
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Rx modulation index."
::= { ifRadio 7 }
txModulationIndex OBJECT-TYPE
SYNTAX ModulationList
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Tx modulation index."
::= { ifRadio 8 }
bandwidth OBJECT-TYPE
SYNTAX INTEGER {
na (0),
bw-28MHz (1),
bw-14MHz (2),
bw-7MHz (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio channel bandwidth. Supported by RAy10 only."
::= { ifRadio 9 }
coding OBJECT-TYPE
SYNTAX INTEGER {
na (0),
low (1),
hi (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Channel coding level. Supported by RAy10 only."
::= { ifRadio 10 }
matching OBJECT-TYPE
SYNTAX OptionSetting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Channel matching."
::= { ifRadio 11 }
rfPowerConfigured OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Configured RF Power in dBm."
::= { ifRadio 12 }
netBitrate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current net bitrate in kbps."
::= { ifRadio 13 }
maxNetBitrate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximum net bitrate in Mbps."
::= { ifRadio 14 }
bandwidthKHz OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio channel bandwidth in kHz. Not supported by RAy10."
::= { ifRadio 15 }
channelArrangement OBJECT-TYPE
SYNTAX INTEGER {
na (0),
accp (1),
acap (2),
ccdp (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Channel arrangement. Not supported by RAy10."
::= { ifRadio 16 }
rfPowerCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current RF Power in dBm. Not supported by RAy10."
::= { ifRadio 17 }
-- ifEth mib
ifEthTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfEthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "List of Ethernet interfaces."
::= { ifEth 1 }
ifEthEntry OBJECT-TYPE
SYNTAX IfEthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Ethernet interface entry."
INDEX { speed }
::= { ifEthTable 1 }
IfEthEntry ::=
SEQUENCE {
speed Integer32,
duplex INTEGER,
mdix INTEGER,
autonego OptionSetting,
pause OptionSetting,
asymPause OptionSetting
}
speed OBJECT-TYPE
SYNTAX Integer32(1..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet speed."
::= { ifEthEntry 1 }
duplex OBJECT-TYPE
SYNTAX INTEGER {
na (0),
full (1),
half (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet duplex."
::= { ifEthEntry 2 }
mdix OBJECT-TYPE
SYNTAX INTEGER {
na (0),
mdi (1),
mdi-x (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet MDI-X / MDI."
::= { ifEthEntry 3 }
autonego OBJECT-TYPE
SYNTAX OptionSetting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet autonego."
::= { ifEthEntry 4 }
pause OBJECT-TYPE
SYNTAX OptionSetting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet pause."
::= { ifEthEntry 5 }
asymPause OBJECT-TYPE
SYNTAX OptionSetting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet asymmetric pause."
::= { ifEthEntry 6 }
prioritized OBJECT-TYPE
SYNTAX OptionSetting
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet prioritized VLAN support. Supported by RAy10 only."
::= { ifEth 2 }
vlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet prioritized VLAN ID. Supported by RAy10 only."
::= { ifEth 3 }
serviceVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ethernet service VLAN ID between local and remote station. Not supported by RAy2."
::= { ifEth 4 }
-- statistic mib
modemR OBJECT IDENTIFIER ::= {statistic 1}
radio OBJECT IDENTIFIER ::= {statistic 2}
ethernet OBJECT IDENTIFIER ::= {statistic 3}
-- statistic radiomodem ethernet mib
rxPauseFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of received Control frames with a valid PAUSE op-code. Supported by RAy10 only."
::= { modemR 1 }
rxControlFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of received Control frames. Supported by RAy10 only."
::= { modemR 2 }
rxBroadcast OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of received packets with a broadcast destination address. Supported by RAy10 only."
::= { modemR 3 }
rxMulticast OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of received packets with a multicast destination address. Supported by RAy10 only."
::= { modemR 4 }
rxDones OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of successfully received packets. Supported by RAy10 only."
::= { modemR 5 }
rxOutOfRangeErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of received frames larger than 1518 bytes (the frame Type/Length field is indicating a value larger than 1518 bytes). Supported by RAy10 only."
::= { modemR 6 }
rxCrcErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of received frames with the CRC which does not match the internally generated CRC. Supported by RAy10 only."
::= { modemR 7 }
rxCodeErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of received packets with one or more erroneous nibbles. Supported by RAy10 only."
::= { modemR 8 }
rxFalseCarrierErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Rx false carrier errors. Supported by RAy10 only."
::= { modemR 9 }
rxDroppedPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of dropped packets. Supported by RAy10 only."
::= { modemR 10 }
rxHCBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of received bytes. Supported by RAy10 only."
::= { modemR 11 }
txPauseFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of transmitted Control frames with a valid PAUSE op-code. Supported by RAy10 only."
::= { modemR 12 }
txControlFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of transmitted Control frames. Supported by RAy10 only."
::= { modemR 13 }
txBroadcast OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of transmitted packets with a broadcast destination address. Supported by RAy10 only."
::= { modemR 14 }
txMulticast OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of transmitted packets with a multicast destination address. Supported by RAy10 only."
::= { modemR 15 }
txDones OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of successfully transmitted packets. Supported by RAy10 only."
::= { modemR 16 }
txLengthCheckErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of transmitted packets with the frame Length field (not a Type field) value that does not match the actual data byte length. Supported by RAy10 only."
::= { modemR 17 }
txCrcErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of transmitted frames with the CRC which does not match the internally generated CRC. Supported by RAy10 only."
::= { modemR 18 }
txCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Tx collisions. Supported by RAy10 only."
::= { modemR 19 }
txHCBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of transmitted bytes. Supported by RAy10 only."
::= { modemR 20 }
-- statistic radio mib
rss OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Receiving RSS indicator in decimal dBm (-39 -> -3,9)."
::= { radio 1 }
snr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Receiving SNR indicator in decimal dB (39 -> 3,9)."
::= { radio 2 }
fecBlockCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total block counter for BER calculation. Block size is 2048 bits. Supported by RAy10 only."
::= { radio 3 }
fecUncorrectBlockCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incorrect block counter for BER calculation. Block size is 2048 bits. Supported by RAy10 only."
::= { radio 4 }
timeAllConnect OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Overall link uptime."
::= { radio 5 }
timeAllDisconnect OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Overall link downtime."
::= { radio 6 }
timeMaxDisconnect OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The longest drop (disconnecting)."
::= { radio 7 }
numDisconnect OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of drops (disconnecting)."
::= { radio 8 }
reliability OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Reliability in thousandths of %."
::= { radio 9 }
linkUptime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current radio link uptime. Not supported by RAy10."
::= { radio 10 }
ber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Bit Error Rate (BER) multiplied by 10^9. Not supported by RAy10."
::= { radio 11 }
-- statistic Ethernet mib
ethInThroughput OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Input Ethernet 1 data port throughput in kbps. Not supported by RAy10."
::= { ethernet 1 }
ethOutThroughput OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Output Ethernet 1 data port throughput in kbps. Not supported by RAy10."
::= { ethernet 2 }
eth2InThroughput OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Input Ethernet 2 data port throughput in kbps. Supported by RAy2 only."
::= { ethernet 3 }
eth2OutThroughput OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Output Ethernet 2 data port throughput in kbps. Supported by RAy2 only."
::= { ethernet 4 }
-- definition traps
airDisconnect NOTIFICATION-TYPE
OBJECTS { lineStatus }
STATUS current
DESCRIPTION
"Air line disconnected. Not supported by RAy2."
::= { rayTraps 1 }
airConnect NOTIFICATION-TYPE
OBJECTS { lineStatus }
STATUS current
DESCRIPTION
"Air line connected after being disconnected. Not supported by RAy2."
::= { rayTraps 2 }
airWdog NOTIFICATION-TYPE
OBJECTS { lineStatus }
STATUS current
DESCRIPTION
"Air watch dog. Supported by RAy10 only."
::= { rayTraps 3 }
tempAlarm NOTIFICATION-TYPE
OBJECTS { temperatureModem }
STATUS current
DESCRIPTION
"Temperature exceeded the threshold. Not supported by RAy2."
::= { rayTraps 4 }
powerAlarm NOTIFICATION-TYPE
OBJECTS { voltageUnit }
STATUS current
DESCRIPTION
"Power voltage is out of the thresholds. Not supported by RAy2."
::= { rayTraps 5 }
memoryAlarm NOTIFICATION-TYPE
OBJECTS { useMemory }
STATUS current
DESCRIPTION
"Memory use exceeded the threshold. Supported by RAy10 only."
::= { rayTraps 6 }
rssAlarm NOTIFICATION-TYPE
OBJECTS { rss }
STATUS current
DESCRIPTION
"RSS exceeded the threshold. Not supported by RAy2."
::= { rayTraps 7 }
snrAlarm NOTIFICATION-TYPE
OBJECTS { snr }
STATUS current
DESCRIPTION
"SNR exceeded the threshold. Not supported by RAy2."
::= { rayTraps 8 }
berAlarm NOTIFICATION-TYPE
OBJECTS { fecUncorrectBlockCounter, fecBlockCounter }
STATUS current
DESCRIPTION
"BER exceeded the threshold. Not supported by RAy2."
::= { rayTraps 9 }
rfPowerFail NOTIFICATION-TYPE
OBJECTS { rfPowerStatus }
STATUS current
DESCRIPTION
"RF Power amplifier failure. Not supported."
::= { rayTraps 10 }
peerEthLinkDown NOTIFICATION-TYPE
OBJECTS { ethPeer }
STATUS current
DESCRIPTION
"Peer station Ethernet link Up/Down. Not supported by RAy2."
::= { rayTraps 11 }
-- RAy2 trap definitions
tr2TemperatureAlarm NOTIFICATION-TYPE
OBJECTS { temperatureModem,
alarmTemperature }
STATUS current
DESCRIPTION
"Temperature exceeded the threshold. Supported by RAy2 only."
::= { ray2Traps 1 }
tr2VoltageLowAlarm NOTIFICATION-TYPE
OBJECTS { voltageUnit,
alarmVoltageLow }
STATUS current
DESCRIPTION
"Supply voltage below minimal threshold. Supported by RAy2 only."
::= { ray2Traps 2 }
tr2VoltageHighAlarm NOTIFICATION-TYPE
OBJECTS { voltageUnit,
alarmVoltageHigh }
STATUS current
DESCRIPTION
"Supply voltage above maximal threshold. Supported by RAy2 only."
::= { ray2Traps 3 }
tr2RssAlarm NOTIFICATION-TYPE
OBJECTS { rss,
alarmRss }
STATUS current
DESCRIPTION
"RSS exceeded the threshold. Supported by RAy2 only."
::= { ray2Traps 4 }
tr2SnrAlarm NOTIFICATION-TYPE
OBJECTS { snr,
alarmSnr }
STATUS current
DESCRIPTION
"SNR exceeded the threshold. Supported by RAy2 only."
::= { ray2Traps 5 }
tr2BerAlarm NOTIFICATION-TYPE
OBJECTS { ber,
alarmBer }
STATUS current
DESCRIPTION
"BER exceeded the threshold. Supported by RAy2 only."
::= { ray2Traps 6 }
tr2AirDisconnect NOTIFICATION-TYPE
OBJECTS { lineStatusII,
alarmPeerDisconnected }
STATUS current
DESCRIPTION
"Air line disconnected. Supported by RAy2 only."
::= { ray2Traps 7 }
tr2AirConnect NOTIFICATION-TYPE
OBJECTS { lineStatusII,
alarmPeerDisconnected }
STATUS current
DESCRIPTION
"Air line connected after being disconnected. Supported by RAy2 (up to fw 2.1.7.0) only."
::= { ray2Traps 8 }
tr2Eth1LinkDown NOTIFICATION-TYPE
OBJECTS { eth1Link,
alarmEth1Down }
STATUS current
DESCRIPTION
"Local station Ethernet 1 link Up/Down. Supported by RAy2 only."
::= { ray2Traps 9 }
tr2Eth21LinkDown NOTIFICATION-TYPE
OBJECTS { eth2Link,
alarmEth2Down }
STATUS current
DESCRIPTION
"Local station Ethernet 2 link Up/Down. Supported by RAy2 only."
::= { ray2Traps 10 }
tr2RfPowerFail NOTIFICATION-TYPE
OBJECTS { rfPowerStatus,
alarmRfPowerFail }
STATUS current
DESCRIPTION
"RF Power amplifier failure. Supported by RAy2 only."
::= { ray2Traps 11 }
tr2NetBitrate NOTIFICATION-TYPE
OBJECTS { netBitrate,
alarmNetBitrate }
STATUS current
DESCRIPTION
"Air speed below threshold. Supported by RAy2 only."
::= { ray2Traps 12 }
tr2WifiOn NOTIFICATION-TYPE
OBJECTS { wifiHAP,
alarmWifiOn }
STATUS current
DESCRIPTION
"WiFi Host Access Point is on. Supported by RAy2 only."
::= { ray2Traps 13 }
END