- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
15402 lines
460 KiB
Text
15402 lines
460 KiB
Text
-- **************************************************************
|
||
-- **************************************************************
|
||
-- +++
|
||
-- Copyright 2001-2008 Symmetricom Austin
|
||
--
|
||
-- FILENAME: SSU2000.MIB
|
||
-- PRODUCT: SSU2000 COMM Module
|
||
-- DESCRIPTION:
|
||
-- This file contains the Symmetricom-Austin SSU2000 private MIB.
|
||
--
|
||
-- NOTES:
|
||
-- In this private MIB, when we define the syntax in Octet String,
|
||
-- we use the subset of the Type-Length-Value (TLV) format (except
|
||
-- we specified otherwise).
|
||
--
|
||
-- The TLV
|
||
-- TYPE (1 byte): indicates the ASN.1 type, as well as
|
||
-- the class of the type.
|
||
-- LENGTH (1 byte): indicates the length of the actual
|
||
-- value represention
|
||
-- VALUE: represents the value of the ASN.1 type as
|
||
-- a string octets.
|
||
--
|
||
-- The (1 byte) type is defined as
|
||
-- Class [bit 6-7], P/C [bit 5], Tag Number [bit 0-4]
|
||
-- Class:
|
||
-- 00 = Universal
|
||
-- 01 = Application
|
||
-- 10 = Context Specific
|
||
-- 11 = Private
|
||
--
|
||
-- P/C:
|
||
-- 0 = Primitive Encoding
|
||
-- 1 = Constructed encoding
|
||
--
|
||
-- Tag Number:
|
||
-- 1 = Boolean type
|
||
-- 2 = Integer
|
||
-- 4 = Octetstring type
|
||
-- 5 = Null type
|
||
-- 10 = Enumerated type
|
||
--
|
||
-- In our application, the type is Application Class with
|
||
-- Primitive Encoding (0x40).
|
||
--
|
||
--
|
||
--
|
||
-- COMMENTS/CHANGES:
|
||
-- JJW 01/11/2001 - Jay Wang: Created
|
||
-- JJW 06/06/2001 - Fixed StaDiMtie1A/B and StaDiMtie2A/B missing mtie100000 definition
|
||
-- JJW 06/22/2001 - Change setMiFreqAErrLmt/setMiFreqBErrLmt setMiFreqAErrLmt/setMiFreqBErrLmt range to [0..10000000]
|
||
-- JJW 06/22/2001 - added extra definition NA for setDiCSFlt.
|
||
-- JJW 06/22/2001 - changed setMiMtie10xxxEL1/2 and setMiMtie10xxxCL1/2 limits to [0..60000] since defined as 16bits.
|
||
-- JJW 09/26/2001 - Changed the Opaque to OCTET STRING
|
||
-- JJW 10/22/2001 - Removed value "warm(1)" in setCkPLLMode
|
||
-- JJW 10/22/2001 - Put stronger check to make sure mtHisInpLoc and tdHisInpLoc specified with port number
|
||
-- JJW 10/22/2001 - Removed value "ignored" in tpNtfCode which is not used.
|
||
-- JJW 01/25/2002 - Added the Composite Clock Input Module, statusCcInp and setupCcInp
|
||
-- JJW 01/25/2002 - Added sysOpmode field in sys to set subtending or non-subtending mode
|
||
-- JJW 02/19/2002 - Allowed additional pql value 1 and 9 be settable in setGpsProvPql, setDiProvPql, and setCiProvPql fields.
|
||
-- JJW 07/09/2002 - Changed setGpsPdop range from 1-10 to 3-10.
|
||
-- JJW 07/09/2002 - Changed setCcComp comments for 275ft per step intead of 500ft per step.
|
||
-- JJW 07/16/2002 - Added inAdapterPart field in InEntry.
|
||
-- JJW 10/02/2002 - Added staOtPortSta range from 1-5 to 1-6 where 6 is defined as port is squelched.
|
||
-- JJW 10/02/2002 - Added setCoSquelch field in SetCoEntry.
|
||
-- JJW 04/01/2003 - Added RS422 Output Module MIB in setup422Out
|
||
-- JJW 05/01/2003 - Changed the MODULE-IDENTITY to Symmetricom
|
||
-- JJW 06/18/2003 - Added E12048 Output Module MIB in setupE12048Out
|
||
-- JJW 09/23/2003 - Restricted snmpmanIp to Read Only for SNMPv3 (It belongs to Level4 function)
|
||
-- JJW 09/23/2003 - Restricted snmpmanInit to v2 and not apply to v3.
|
||
-- JJW 11/20/2003 - Changed setCkMinTau and setCkMaxTau ranges from (300..10000) to (150..10000)
|
||
-- JJW 01/08/2004 - Added DS1 LRM Module MIB in statusLrm and setupLrm
|
||
-- JJW 02/06/2004 - Added pllflt(6) in staLrmMRefSrc field
|
||
-- JJW 02/06/2004 - Added unknown(4) in staLrmMCtaId field
|
||
-- JJW 03/05/2004 - Added etl1c(10) and etl1d(11) in comLogoff fields.
|
||
-- JJW 03/05/2004 - Added etl1c(10) and etl1d(11) in whoPort fields.
|
||
-- JJW 03/08/2004 - Allowed pql value 1 thru 9 be settable in setGpsProvPql, setDiProvPql, and setCiProvPql fields.
|
||
-- JJW 03/08/2004 - Added sysTl1Format(sys 5)object in sys object.
|
||
-- JJW 03/29/2004 - Added Sine Output Module MIB in setupSineOut
|
||
-- JJW 03/29/2004 - Added Sine Input Module MIB in setupSineInp and statusSineInp
|
||
-- JJW 03/29/2004 - Added Japanese Composite Clock Output Module MIB in setupJccOut
|
||
-- JJW 03/29/2004 - Added Japanese Composite Clock Input Module MIB in setupJccInp and statusJccInp
|
||
-- JJW 07/23/2004 - Added japanese(3)in sysOpmode fields (i.e. Japanese subtending mode).
|
||
-- JJW 10/11/2004 - Changed the stGpsTkChnl from 1..8 to 1..12
|
||
-- JJW 01/12/2005 - added xxxMStatus (module status) fields for all input modules.
|
||
-- JJW 01/14/2005 - Tracker #20460, limited pql value 1 and 9 be settable in setGpsProvPql, setDiProvPql, setCiProvPql, setSineiProvPql, setJcciProvPql fields.
|
||
-- JJW 02/01/2005 - RES #3321, Added/changed snmpman objects and fields for new v3 implementation
|
||
-- renamed snmpmanTable to snmpv2manTable
|
||
-- added initv2 and initv3 fields in snmpmanInit object
|
||
-- added snmpNotification, snmpEnable, snmpv3manTable, snmpv2userTable, snmpv3userTable objects
|
||
-- JJW 02/01/2005 - Added sInterfaces(ssu2000 60) object to specify if various interfaces present or not.
|
||
-- JJW 02/01/2005 - RES #3464, Added E1 LRM Module MIB in statusLrme1 and setupLrme1.
|
||
-- JJW 02/01/2005 - removed statusCdma (mstatus 6) and setupCdma (msetup 6) in the msetup object.
|
||
-- JJW 02/01/2005 - Tracker #20519, added setGpsZeroPhase field in SetGpsEntry.
|
||
-- JJW 02/22/2005 - Tracker #20553, applied "ssu2000 MODULE-IDENTITY" OID with {austron 1 1} instead of {products 1} (note: both are the same OID)
|
||
-- to avoid conflicts within HP Openview with some MIBs from other vendors.
|
||
-- JJW 02/22/2005 - Tracker #20545, removed unnecessary fields in the CC inp module of StaCiEntry, SetCiEntry, and SetCimEntry.
|
||
-- JJW 05/20/2005 - Tracker #20580, added fields setE12048oFrame, setE12048oCrc, setE12048oSsm, setE12048oCrc and setE12048oSsmBit in SetE12048oEntry.
|
||
-- JJW 08/26/2005 - Tracker #21166, added sysAco 'alarm cut off' (sys 7) in sys object.
|
||
-- JJW 02/22/2006 - Version realignment.
|
||
-- JJW 03/28/2006 - Added more description in TModuleCode hex number module definition.
|
||
-- JJW 03/29/2006 - Tracker #21301, Added ntpPrefer (ntp 12) in the ntp object.
|
||
-- JJW 03/30/2006 - Tracker #20656, Added tmLocalOffset (time 2) in the time object and TLocalTimeOffset definition.
|
||
-- JJW 04/25/2006 - Tracker #20639, Added GPS Performance Monitor (MTIE and FREQ)
|
||
-- added staGpsMtie1A, staGpsMtie2A, staGpsMtie1B, staGpsMtie2B, staGpsFreqA, staGpsFreqB to StaGpsEntry object.
|
||
-- added setAlmThGpsInpTable object in (setupGps 2) for MTIE and FREQ setting.
|
||
-- JJW 06/20/2006 - Tracker #21475, Changed the limitis from 1-100k, to 1-10k in setMiOOFErrCnt,setMiOOFClrCnt,setMiBPVErrCnt,
|
||
-- setMiBPVClrCnt, setMiCRCErrCnt,and setMiCRCClrCnt in the DS1/E1 input module.
|
||
-- setCimBPVErrCnt and setCimBPVClrCnt in the CC Input Module
|
||
-- JJW 10/18/2006 - Tracker #22077, Added alarm threshold setting in the Sine Input Module:
|
||
-- added fields in staSineiPql, staSineiMtie1A, staSineiMtie2A, staSineiMtie1B, staSineiMtie2B,
|
||
-- staSineiFreqA, staSineiFreqB in the staSineiEntry.
|
||
-- added a new object table setAlmThSineInpTable in setupSineInp object.
|
||
-- JJW 10/18/2006 - Tracker #21780, Added staGpsPpsSigma and staGps3Sigma in the StaGpsEntry object.
|
||
-- JJW 01/25/2008 - PRD 5.1, Added PackeTime NTP Module Support:
|
||
-- Added statusPtNtp object in mstatus (15),
|
||
-- Added setupPtNtp object in msetup (22),
|
||
-- Added ntpq object in ssu2000 (19),
|
||
-- Added route object in ssu2000 (20),
|
||
-- Added setCkTodTimeout field in the setCkEntry(7)
|
||
-- Added staCkUtc field in the staCkEntry(7)
|
||
-- Added refClkTodsrc field in the ref(7)
|
||
-- Added setGpsTodsrcPriority(14) and setGpsTodsrcCompensation(15) field in the setGpsEntry.
|
||
-- JJW 02/02/2012 - PRD 6.4, Added following support:
|
||
-- Added statusPtPtp object in mstatus (16),
|
||
-- Added setupPtPtp object in msetup (23),
|
||
-- Added ptpclient object in ssu2000 (36),
|
||
-- Added almStatus field in almEntry (9),
|
||
-- Added statusSynce object in mstatus (17),
|
||
-- Added setupSynce object in msetup (24),
|
||
-- Added setPtPtpRmvClient field in setPtPtpEntry (34)
|
||
-- Added setCkFreqTimeout field in the setCkEntry(8)
|
||
-- GGUO 07/08/2012 - PRD GLONASS, Added following support:
|
||
-- Added setGnssCmode field in the setGpsEntry (16),
|
||
-- Added new option for setGpsEngine field in the setGpsEntry(3)
|
||
-- modified stGpsTkChnl from 12 TO 32,
|
||
-- modified stGpsAvChnl from 12 TO 32,
|
||
-- modified setGpsAvg from 10..3600 to 20..3600, and also the method will
|
||
-- make GSP to be 20..3600, and GNSS to be 20..1440
|
||
-- modified setGpsPosel from (0..60)to (0..90)
|
||
-- modified setGpsTimel from (0..60)to (0..90)
|
||
--
|
||
-- CURRENT VERSION:
|
||
-- Part No - 12613127-002-2
|
||
-- 04/16/2001 - A.00
|
||
-- 07/06/2001 - A.01
|
||
-- 01/21/2002 - A.02
|
||
-- 07/17/2002 - B.00 (ECN#: 2167)
|
||
-- 10/22/2002 - C.00 (ECN#: 2241)
|
||
-- 05/15/2003 - D.00 (ECO#: 7735)
|
||
-- 09/09/2003 - E.00 (ECO#: 7825)
|
||
-- 01/14/2004 - F.00 (ECO#: 7946)
|
||
-- 02/06/2004 - F.01 (ECO#: 7969)
|
||
-- 03/05/2004 - F.02 (ECO#: 8021)
|
||
-- 09/03/2004 - G.00 (ECO#: 8139)
|
||
-- 02/01/2005 - G.01 (ECO#: 8302)
|
||
-- 03/25/2005 - H.00 (ECO#: 8369)
|
||
-- 09/29/2005 - J.00 (ECO#: 8483)
|
||
-- 02/22/2006 - K.00 (ECO#: 8600)
|
||
-- 07/06/2006 - L.00 (ECO#: 8762)
|
||
-- 11/03/2006 - L.01 (ECO#: 8936)
|
||
-- 06/10/2008 - M.00 (EC0#: 0190)
|
||
-- 03/08/2012 - N.00 (EC07565)
|
||
-- 08/17/2012 - P.00
|
||
--
|
||
-- +++
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
|
||
SSU2000-MIB DEFINITIONS ::= BEGIN
|
||
|
||
|
||
IMPORTS
|
||
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
||
OBJECT-IDENTITY,Counter32,
|
||
IpAddress
|
||
FROM SNMPv2-SMI
|
||
|
||
DisplayString,TEXTUAL-CONVENTION
|
||
FROM SNMPv2-TC
|
||
|
||
austron
|
||
FROM DATUM-MIB;
|
||
|
||
|
||
ssu2000 MODULE-IDENTITY
|
||
-- YYMMDD0000Z the LAST-UPDATED format
|
||
LAST-UPDATED "0801140000Z"
|
||
ORGANIZATION "Symmetricom"
|
||
CONTACT-INFO
|
||
"
|
||
Symmetricom Technical Support
|
||
1-888-367-7966 toll free USA
|
||
1-408-428-7907 worldwide
|
||
Support@symmetricom.com
|
||
"
|
||
DESCRIPTION
|
||
"Private MIB module for management of SSU2000.
|
||
This SSU2000 private MIB supports all existing
|
||
functions of the SSU2000 thus achieving full system
|
||
control via this software interface. All reports,
|
||
queries, autonomous messages, control, provisioning
|
||
and administration (except for Set User ID/password/level,
|
||
Set IP assignments, Reset Connection and SNMP Community
|
||
Settings) will be addressable via SNMP.
|
||
"
|
||
::= { austron 1 1 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 PRIVATE MIB, TOP-LEVEL TREE STRUCTURE
|
||
-- **************************************************************
|
||
|
||
inventory OBJECT IDENTIFIER ::= { ssu2000 1 }
|
||
mstatus OBJECT IDENTIFIER ::= { ssu2000 2 }
|
||
msetup OBJECT IDENTIFIER ::= { ssu2000 3 }
|
||
general OBJECT IDENTIFIER ::= { ssu2000 4 }
|
||
event OBJECT IDENTIFIER ::= { ssu2000 5 }
|
||
alarm OBJECT IDENTIFIER ::= { ssu2000 6 }
|
||
ref OBJECT IDENTIFIER ::= { ssu2000 7 }
|
||
phase OBJECT IDENTIFIER ::= { ssu2000 8 }
|
||
freq OBJECT IDENTIFIER ::= { ssu2000 9 }
|
||
ntp OBJECT IDENTIFIER ::= { ssu2000 10 }
|
||
time OBJECT IDENTIFIER ::= { ssu2000 11 }
|
||
pqlTable OBJECT IDENTIFIER ::= { ssu2000 12 }
|
||
ioname OBJECT IDENTIFIER ::= { ssu2000 13 }
|
||
comm OBJECT IDENTIFIER ::= { ssu2000 14 }
|
||
snmpman OBJECT IDENTIFIER ::= { ssu2000 15 }
|
||
sys OBJECT IDENTIFIER ::= { ssu2000 16 }
|
||
users OBJECT IDENTIFIER ::= { ssu2000 17 }
|
||
who OBJECT IDENTIFIER ::= { ssu2000 18 }
|
||
ntpq OBJECT IDENTIFIER ::= { ssu2000 19 }
|
||
route OBJECT IDENTIFIER ::= { ssu2000 20 }
|
||
|
||
mtie OBJECT IDENTIFIER ::= { ssu2000 30 }
|
||
tdev OBJECT IDENTIFIER ::= { ssu2000 31 }
|
||
|
||
-- s1port OBJECT IDENTIFIER ::= { ssu2000 32 }
|
||
-- phaseT1 OBJECT IDENTIFIER ::= { ssu2000 33 }
|
||
-- tie100 OBJECT IDENTIFIER ::= { ssu2000 34 }
|
||
-- mtie100 OBJECT IDENTIFIER ::= { ssu2000 35 }
|
||
ptpclient OBJECT IDENTIFIER ::= { ssu2000 36 }
|
||
|
||
mTrapReq OBJECT IDENTIFIER ::= { ssu2000 50 }
|
||
mTrapObjs OBJECT IDENTIFIER ::= { ssu2000 51 }
|
||
mTraps OBJECT IDENTIFIER ::= { ssu2000 52 }
|
||
|
||
sInterfaces OBJECT IDENTIFIER ::= { ssu2000 60 }
|
||
|
||
|
||
--
|
||
-- status
|
||
--
|
||
statusCom OBJECT IDENTIFIER ::= { mstatus 1 }
|
||
statusClk OBJECT IDENTIFIER ::= { mstatus 2 }
|
||
statusGps OBJECT IDENTIFIER ::= { mstatus 5 }
|
||
statusDs1E1Inp OBJECT IDENTIFIER ::= { mstatus 7 }
|
||
statusCcInp OBJECT IDENTIFIER ::= { mstatus 8 }
|
||
statusOut OBJECT IDENTIFIER ::= { mstatus 10 }
|
||
statusLrm OBJECT IDENTIFIER ::= { mstatus 11 }
|
||
statusSineInp OBJECT IDENTIFIER ::= { mstatus 12 }
|
||
statusJccInp OBJECT IDENTIFIER ::= { mstatus 13 }
|
||
statusLrmE1 OBJECT IDENTIFIER ::= { mstatus 14 }
|
||
statusPtNtp OBJECT IDENTIFIER ::= { mstatus 15 }
|
||
statusPtPtp OBJECT IDENTIFIER ::= { mstatus 16 }
|
||
statusSynce OBJECT IDENTIFIER ::= { mstatus 17 }
|
||
|
||
|
||
--
|
||
-- setup
|
||
--
|
||
setupCom OBJECT IDENTIFIER ::= { msetup 1 }
|
||
setupClk OBJECT IDENTIFIER ::= { msetup 2 }
|
||
setupGps OBJECT IDENTIFIER ::= { msetup 5 }
|
||
setupDs1E1Inp OBJECT IDENTIFIER ::= { msetup 7 }
|
||
setupCcInp OBJECT IDENTIFIER ::= { msetup 8 }
|
||
setupDs1Out OBJECT IDENTIFIER ::= { msetup 10 }
|
||
setupE1Out OBJECT IDENTIFIER ::= { msetup 11 }
|
||
setup2048Out OBJECT IDENTIFIER ::= { msetup 12 }
|
||
setupCCOut OBJECT IDENTIFIER ::= { msetup 13 }
|
||
setup422Out OBJECT IDENTIFIER ::= { msetup 14 }
|
||
setupE12048Out OBJECT IDENTIFIER ::= { msetup 15 }
|
||
setupLrm OBJECT IDENTIFIER ::= { msetup 16 }
|
||
setupSineOut OBJECT IDENTIFIER ::= { msetup 17 }
|
||
setupSineInp OBJECT IDENTIFIER ::= { msetup 18 }
|
||
setupJccOut OBJECT IDENTIFIER ::= { msetup 19 }
|
||
setupJccInp OBJECT IDENTIFIER ::= { msetup 20 }
|
||
setupLrmE1 OBJECT IDENTIFIER ::= { msetup 21 }
|
||
setupPtNtp OBJECT IDENTIFIER ::= { msetup 22 }
|
||
setupPtPtp OBJECT IDENTIFIER ::= { msetup 23 }
|
||
setupSynce OBJECT IDENTIFIER ::= { msetup 24 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 TEXTUAL-CONVENTION DEFINITION
|
||
-- **************************************************************
|
||
|
||
OkValue ::= INTEGER { ok (1), fault (2) }
|
||
OnValue ::= INTEGER { on (1), off (2) }
|
||
YesValue ::= INTEGER { yes (1), no (2) }
|
||
EnaValue ::= INTEGER { ena (1), dis (2) }
|
||
ActiveValue ::= INTEGER { active (1), inactive (2) }
|
||
ValidValue ::= INTEGER { valid (1), invalid (2) }
|
||
TrueValue ::= INTEGER { true (1), false (2) }
|
||
|
||
|
||
-- ******************************************
|
||
-- DEFINED IN RFC2579
|
||
-- ******************************************
|
||
|
||
DateAndTime ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "2d-1d-1d,1d:1d:1d.1d,1a1d:1d"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A date-time specification.
|
||
|
||
field octets contents range
|
||
----- ------ -------- -----
|
||
1 1-2 year* 0..65536
|
||
2 3 month 1..12
|
||
3 4 day 1..31
|
||
4 5 hour 0..23
|
||
5 6 minutes 0..59
|
||
6 7 seconds 0..60
|
||
(use 60 for leap-second)
|
||
7 8 deci-seconds 0..9
|
||
8 9 direction from UTC '+' / '-'
|
||
9 10 hours from UTC* 0..13
|
||
10 11 minutes from UTC 0..59
|
||
|
||
* Notes:
|
||
- the value of year is in network-byte order
|
||
- daylight saving time in New Zealand is +13
|
||
|
||
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be
|
||
displayed as:
|
||
|
||
1992-5-26,13:30:15.0,-4:0
|
||
|
||
|
||
Note that if only local time is known, then timezone
|
||
information (fields 8-10) is not present."
|
||
SYNTAX OCTET STRING (SIZE (8 | 11))
|
||
|
||
|
||
-- ******************************************
|
||
-- LOCAL TIME OFFSET DEFINITION
|
||
-- ******************************************
|
||
|
||
TLocalTimeOffset ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "1a1d:1d"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A local time offset specification.
|
||
|
||
field octets contents range
|
||
----- ------ -------- -----
|
||
1 1 direction from UTC '+' / '-'
|
||
2 2 hours from UTC* 0..13
|
||
3 3 minutes from UTC 0..59
|
||
|
||
* Notes:
|
||
- the value of year is in network-byte order
|
||
- The hours range is 0..13
|
||
|
||
For example, the -6 local time offset would be
|
||
displayed as: -6:0
|
||
"
|
||
SYNTAX OCTET STRING (SIZE (3))
|
||
|
||
|
||
-- ******************************************
|
||
-- MODULE HEX CODE DEFINITION
|
||
-- ******************************************
|
||
|
||
TModuleCode ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "x"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The module hex code
|
||
1001 Input <20> 3 Port
|
||
1002 Input <20> 1 Port
|
||
1003 Input <20> DS1 3 Port
|
||
1004 Input <20> DS1 1 Port
|
||
1005 Input <20> E1 3 Port
|
||
1006 Input <20> E1 1 Port
|
||
1008 Input <20> GPS
|
||
1010 Input <20> Composite Clock (1 Port)
|
||
1012 Input <20> Japanese CC (1 Port)
|
||
1013 Input <20> Japanese Sine (3 Port)
|
||
2001 Clock <20> Stratum 2E Rubidium
|
||
2002 Clock <20> Stratum 3E
|
||
2003 Clock <20> Type I
|
||
3001 Communication Module
|
||
4001 Output <20> DS1
|
||
4002 Output <20> E1
|
||
4003 Output <20> Composite Clock
|
||
4004 Output <20> 2048 kHz
|
||
4007 Output <20> EIA 422
|
||
4008 Output <20> E1/2048 kHz
|
||
4009 DS1 Line Retiming Module 4 Ports
|
||
400A DS1 Line Retiming Module 2 Ports
|
||
400B Output <20> Japanese CC
|
||
400C Output <20> Japanese Sine
|
||
400D E1 Line Retiming Module 4 Ports
|
||
4021 NTP Blade
|
||
4022 PTP Blade
|
||
5001 Buffer Card
|
||
"
|
||
SYNTAX INTEGER (0..'FFFF'h)
|
||
|
||
|
||
-- ******************************************
|
||
-- SYNC STATUS MESSAGE (SSM) DEFINITION
|
||
-- ******************************************
|
||
|
||
TSsm ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "x"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The ssm hex code"
|
||
SYNTAX INTEGER (0..255)
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- ANTENNA LATITUDE AND LONGITUDE DEFINITION
|
||
-- ******************************************
|
||
|
||
TLatAndLon ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "1a1d:1d:1d.1d"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"antenna latitude and longitude specification.
|
||
|
||
field octets contents range
|
||
----- ------ -------- -----
|
||
1 1 +/-180 deg '+' / '-'
|
||
2 2 degree 0..180
|
||
3 3 minute 0..59
|
||
4 4 second 0..59
|
||
5 5 second fraction 0..99
|
||
|
||
+/- dd:mm:ss.ss
|
||
"
|
||
SYNTAX OCTET STRING (SIZE (5))
|
||
|
||
|
||
-- ******************************************
|
||
-- ANTENNA HIGHT DEFINITION
|
||
-- ******************************************
|
||
|
||
TAntHeight ::= TEXTUAL-CONVENTION
|
||
DISPLAY-HINT "1a2d.1d"
|
||
STATUS current
|
||
DESCRIPTION
|
||
"antenna height specification.
|
||
|
||
field octets contents range
|
||
----- ------ -------- -----
|
||
1 1 +/- '+' / '-'
|
||
2 2-3 meter 0..10000
|
||
3 4 meter fraction 0..99
|
||
|
||
+/- hh.hh
|
||
|
||
"
|
||
SYNTAX OCTET STRING (SIZE (4))
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 INVENTORY GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
inventoryTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF InEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list containing the system inventory of installed hardware and software components contained in the SSU-2000.
|
||
The number of entries is given by the values of inChassis and inSlot.
|
||
"
|
||
::= { inventory 1 }
|
||
|
||
|
||
inEntry OBJECT-TYPE
|
||
SYNTAX InEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Inventory table contains inventory information for all modules installed in the SSU2000 unit.
|
||
System Inventory attributes.
|
||
"
|
||
INDEX { inChassis, inSlot }
|
||
::= { inventoryTable 1 }
|
||
|
||
|
||
InEntry ::=
|
||
SEQUENCE {
|
||
inChassis
|
||
INTEGER,
|
||
inSlot
|
||
INTEGER,
|
||
inModCode
|
||
TModuleCode,
|
||
inName
|
||
DisplayString,
|
||
inSerial
|
||
DisplayString,
|
||
inService
|
||
DateAndTime,
|
||
inHwPart
|
||
DisplayString,
|
||
inHwRev
|
||
DisplayString,
|
||
inHwDate
|
||
DateAndTime,
|
||
inSwPart
|
||
DisplayString,
|
||
inSwRev
|
||
DisplayString,
|
||
inRevision
|
||
DisplayString,
|
||
inShelfDesc
|
||
DisplayString,
|
||
inShelfPart
|
||
DisplayString,
|
||
inInstalled
|
||
YesValue,
|
||
inAction
|
||
INTEGER,
|
||
inAdapterPart
|
||
DisplayString
|
||
}
|
||
|
||
inChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { inEntry 1 }
|
||
|
||
inSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { inEntry 2 }
|
||
|
||
inModCode OBJECT-TYPE
|
||
SYNTAX TModuleCode
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module type is identified with a Hex value.
|
||
"
|
||
::= { inEntry 3 }
|
||
|
||
|
||
inName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module type is identified with a Name.
|
||
"
|
||
::= { inEntry 4 }
|
||
|
||
inSerial OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's serial number.
|
||
"
|
||
::= { inEntry 5 }
|
||
|
||
inService OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's in-service time.
|
||
"
|
||
::= { inEntry 6 }
|
||
|
||
inHwPart OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's hardware part number.
|
||
"
|
||
::= { inEntry 7 }
|
||
|
||
inHwRev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's hardware revision.
|
||
"
|
||
::= { inEntry 8 }
|
||
|
||
inHwDate OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's date of manufacture.
|
||
"
|
||
::= { inEntry 9 }
|
||
|
||
inSwPart OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's software part number.
|
||
"
|
||
::= { inEntry 10 }
|
||
|
||
inSwRev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's main software revision.
|
||
"
|
||
::= { inEntry 11 }
|
||
|
||
inRevision OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..60))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports module's software and PLD revisions.
|
||
"
|
||
::= { inEntry 12 }
|
||
|
||
inShelfDesc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports shelf type description.
|
||
"
|
||
::= { inEntry 13 }
|
||
|
||
inShelfPart OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports shelf part number.
|
||
"
|
||
::= { inEntry 14 }
|
||
|
||
inInstalled OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if this module is physically installed in the system or not.
|
||
1 = module is installed.
|
||
2 = module is physically absent, but the configuration data is still there.
|
||
"
|
||
::= { inEntry 15 }
|
||
|
||
inAction OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2),
|
||
remove(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User Action:
|
||
ENABLE (1), enables the module.
|
||
DISABLE (2), marks a module as inactive to be removed from the system.
|
||
REMOVE (3), if physically absent, the module is removed from the registry.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
When read, it always displayed as 1.
|
||
"
|
||
::= { inEntry 16 }
|
||
|
||
|
||
inAdapterPart OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the Symmetricom input adapter part number.
|
||
Note: If this field is an empty string, it means the input adapter identification is not applicable for this module.
|
||
"
|
||
::= { inEntry 17 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 FEATURE PRESENCE TABLE
|
||
-- **************************************************************
|
||
|
||
inFeatureTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF InFeatureEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The SSU-2000 has two optional features, NTP and SNMP.
|
||
The Feature Presence table provides presence of these features.
|
||
"
|
||
::= { inventory 2 }
|
||
|
||
inFeatureEntry OBJECT-TYPE
|
||
SYNTAX InFeatureEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"inFeatureIndex
|
||
The index to identify the feature
|
||
inFeature
|
||
The setting of the feature
|
||
"
|
||
INDEX { inFeatureIndex }
|
||
::= { inFeatureTable 1 }
|
||
|
||
|
||
InFeatureEntry ::=
|
||
SEQUENCE {
|
||
inFeatureIndex
|
||
INTEGER,
|
||
inFeature
|
||
EnaValue
|
||
}
|
||
|
||
inFeatureIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A unique value for each feature table.
|
||
1 = NTP
|
||
2 = SNMP
|
||
"
|
||
::= { inFeatureEntry 1 }
|
||
|
||
|
||
inFeature OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SSU-2000 feature set:
|
||
1 = Enabled
|
||
2 = Disabled
|
||
"
|
||
::= { inFeatureEntry 2 }
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- FUNCTIONAL DESCRIPTION
|
||
-- The module status group provides information on each module
|
||
-- installed in the system. There are status attributes that are
|
||
-- common for all modules in the system and there are module
|
||
-- specific attributes. All of the status attributes are
|
||
-- read-only objects. Descriptions of the specific module
|
||
-- attributes are listed in each Module Status Group for each type
|
||
-- of module.
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 COMMUNICATION MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
-- FUNCTIONAL DESCRIPTION
|
||
-- The module status group provides information on each module
|
||
-- installed in the system. There are status attributes that are
|
||
-- common for all modules in the system and there are module
|
||
-- specific attributes. All of the status attributes are
|
||
-- read-only objects. Descriptions of the specific module
|
||
-- attributes are listed in each Module Status Group for each type
|
||
-- of module.
|
||
-- Though the Status Information will show alarm status (if a module
|
||
-- is in an alarmed state or not), the detail of all alarm states
|
||
-- is available through the module's alarm object.
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 CLOCK MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staClkTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaCkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports Clock Module Status, loop mode, tau, and system-level priority quality level (pql).
|
||
"
|
||
::= { statusClk 1 }
|
||
|
||
|
||
staCkEntry OBJECT-TYPE
|
||
SYNTAX StaCkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clock Status Attributes:
|
||
"
|
||
INDEX { staCkChassis, staCkSlot}
|
||
::= { staClkTable 1 }
|
||
|
||
StaCkEntry ::=
|
||
SEQUENCE {
|
||
staCkChassis
|
||
INTEGER,
|
||
staCkSlot
|
||
INTEGER,
|
||
staCkStatus
|
||
INTEGER,
|
||
staCkPLLMode
|
||
INTEGER,
|
||
staCkTau
|
||
Counter32,
|
||
staCkPql
|
||
INTEGER,
|
||
staCkUtc
|
||
YesValue
|
||
}
|
||
|
||
staCkChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { staCkEntry 1 }
|
||
|
||
staCkSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This slot number and chassis number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for Clocks are slot 1 and slot 12.
|
||
"
|
||
::= { staCkEntry 2 }
|
||
|
||
|
||
staCkStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the clock module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
selected(2), -- module is enabled and selected as primary local oscillator
|
||
disable(3), -- module is disabled
|
||
fault(4) -- module is enabled and operating with fault(s)
|
||
"
|
||
::= { staCkEntry 3 }
|
||
|
||
staCkPLLMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
failed(1),
|
||
warmup(2),
|
||
acquire(3),
|
||
holdover(4),
|
||
lock(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the clock software Phase Locked Loop (PLL) Mode.
|
||
failed(1), -- pll hardware failure, pll unlocked
|
||
warmup(2), -- local oscillator is initialized and warming up
|
||
acquire(3), -- LO is operating in acquire or fast locked mode
|
||
holdover(4), -- LO is operating in holdover due to lose or reference input
|
||
lock(5) -- LO is operating in normal mode
|
||
"
|
||
::= { staCkEntry 4 }
|
||
|
||
staCkTau OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the clock tau value.
|
||
The tau is the time constant (in seconds) used by the clock's servo control loop.
|
||
"
|
||
::= { staCkEntry 5 }
|
||
|
||
staCkPql OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the system Priority Quality Level (PQL).
|
||
The PQL indicates the Stratum Level of the clock.
|
||
Zero indicates an invalid SSM was read.
|
||
"
|
||
::= { staCkEntry 6 }
|
||
|
||
staCkUtc OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the clock has been TOD synced with GPS or PackeTime..
|
||
"
|
||
::= { staCkEntry 7 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 GPS MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- GPS STATUS TABLE
|
||
-- ******************************************
|
||
|
||
staGpsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaGpsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The GPS Input Module Status reports the module's current status, input port phase data,
|
||
time status, MTIE threshold status, frequency threshold status, and TIE measurement statistics status.
|
||
"
|
||
::= { statusGps 1 }
|
||
|
||
staGpsEntry OBJECT-TYPE
|
||
SYNTAX StaGpsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"GPS Status Attributes:
|
||
staGpsChassis
|
||
Identifies which chassis is being addressed
|
||
stGpskSlot
|
||
Identifies which slot is being addressed
|
||
staGpsMStatus
|
||
Reports module status
|
||
staGpsStatus
|
||
Reports gps input port status
|
||
staGpsPhaseA
|
||
Reports phase value versus clock A in nano-seconds.
|
||
staGpsPhaseB
|
||
Reports phase value versus clock B in nano-seconds.
|
||
staGpsUtc
|
||
Reports number tells us whether the GPS module has UTC time or not.
|
||
staGpsMtie1A
|
||
Reports which MTIE limit 1 threshold was exceeded on clock A.
|
||
staGpsMtie2A
|
||
Reports which MTIE limit 2 threshold was exceeded on clock A.
|
||
staGpsMtie1B
|
||
Reports which MTIE limit 1 threshold was exceeded on clock B.
|
||
staGpsMtie2B
|
||
Reports which MTIE limit 2 threshold was exceeded on clock B.
|
||
staGpsFreqA
|
||
Reports input port frequency threshold exceeded on clock A.
|
||
staGpsFreqB
|
||
Reports input port frequency threshold exceeded on clock B.
|
||
staGpsPpsSigma
|
||
Reports sigma (statistical) calculation representing noise variation on the GPS 1PPS
|
||
staGps3Sigma
|
||
Reports 3sigma (statistical) calculation representing noise variation on the GPS 1PPS
|
||
"
|
||
INDEX { staGpsChassis, staGpsSlot}
|
||
::= { staGpsTable 1 }
|
||
|
||
|
||
StaGpsEntry ::=
|
||
SEQUENCE {
|
||
staGpsChassis
|
||
INTEGER,
|
||
staGpsSlot
|
||
INTEGER,
|
||
staGpsStatus
|
||
INTEGER,
|
||
staGpsPhaseA
|
||
INTEGER,
|
||
staGpsPhaseB
|
||
INTEGER,
|
||
staGpsUtc
|
||
YesValue,
|
||
staGpsMStatus
|
||
INTEGER,
|
||
|
||
-- MTIE THRESHOLD STATUS
|
||
staGpsMtie1A
|
||
INTEGER,
|
||
staGpsMtie2A
|
||
INTEGER,
|
||
staGpsMtie1B
|
||
INTEGER,
|
||
staGpsMtie2B
|
||
INTEGER,
|
||
|
||
-- FREQUENCY THRESHOLD STATUS
|
||
staGpsFreqA
|
||
OkValue,
|
||
staGpsFreqB
|
||
OkValue,
|
||
|
||
-- SIGMA Values
|
||
staGpsPpsSigma
|
||
DisplayString,
|
||
|
||
staGps3Sigma
|
||
DisplayString
|
||
}
|
||
|
||
staGpsChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { staGpsEntry 1 }
|
||
|
||
staGpsSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { staGpsEntry 2 }
|
||
|
||
|
||
staGpsStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4),
|
||
reject(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The GPS port status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
selected(2), -- module is enabled and selected as input reference
|
||
disable(3), -- module is disabled
|
||
fault(4), -- module is enabled and operating with faults
|
||
reject(5) -- module is rejected due to antenna failure
|
||
"
|
||
::= { staGpsEntry 3 }
|
||
|
||
staGpsPhaseA OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The phase value versus clock A.
|
||
The phaseA is the current 1 second phase value in nanoseconds on clock A.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staGpsEntry 4 }
|
||
|
||
staGpsPhaseB OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports phase value versus clock B.
|
||
The phaseB is the current 1 second phase value in nanoseconds on clock B.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staGpsEntry 5 }
|
||
|
||
staGpsUtc OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the GPS module has been set to UTC time (or not).
|
||
1 = time is available
|
||
2 = time is not available
|
||
"
|
||
::= { staGpsEntry 6 }
|
||
|
||
staGpsMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(2),
|
||
fault(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the GPS module status.
|
||
ok(1), -- module is enabled and operating normally
|
||
disable(2), -- module is disabled
|
||
fault(3) -- module is enabled, but not operational due to faults
|
||
"
|
||
::= { staGpsEntry 7 }
|
||
|
||
staGpsMtie1A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded on clock A.
|
||
If ok, it means no error for MTIE limit 1 on clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded on clock A.
|
||
"
|
||
::= { staGpsEntry 8 }
|
||
|
||
staGpsMtie2A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded on clock A.
|
||
If ok, it means no error for MTIE limit 2 on clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded on clock A.
|
||
"
|
||
::= { staGpsEntry 9 }
|
||
|
||
|
||
staGpsMtie1B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded on clock B.
|
||
If ok, it means no error for MTIE limit 1 on clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded on clock B.
|
||
"
|
||
::= { staGpsEntry 10 }
|
||
|
||
|
||
staGpsMtie2B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded on clock B.
|
||
If ok, it means no error for MTIE limit 2 on clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded on clock B.
|
||
"
|
||
::= { staGpsEntry 11 }
|
||
|
||
|
||
staGpsFreqA OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the input port frequency threshold exceeded on clock A.
|
||
"
|
||
::= { staGpsEntry 12 }
|
||
|
||
|
||
staGpsFreqB OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the input port frequency threshold exceeded on clock B.
|
||
"
|
||
::= { staGpsEntry 13 }
|
||
|
||
|
||
staGpsPpsSigma OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports current 1 PPS Sigma.
|
||
"
|
||
::= { staGpsEntry 14 }
|
||
|
||
staGps3Sigma OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports current 3 Sigma Threshold.
|
||
"
|
||
::= { staGpsEntry 15 }
|
||
|
||
-- ******************************************
|
||
-- GPS ENGINE POSITION TABLE
|
||
-- ******************************************
|
||
|
||
stGpsPosTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StGpsPosEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The GPS attributes that report the status of the GPS engine's position and status
|
||
"
|
||
::= { statusGps 2 }
|
||
|
||
|
||
stGpsPosEntry OBJECT-TYPE
|
||
SYNTAX StGpsPosEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The GPS position attributes:
|
||
stGpsPosChassis
|
||
Identifies which chassis is being addressed
|
||
stGpsPosSlot
|
||
Identifies which slot is being addressed
|
||
stGpsPosValid
|
||
Reports if the GPS position is valid or not.
|
||
stGpsPosLat
|
||
Reports antenna latitude position of the GPS module.
|
||
stGpsPosLon
|
||
Reports antenna longitude position of the GPS module.
|
||
stGpsPosHgt
|
||
Reports antenna height (meter) position of the GPS module.
|
||
stGpsPosAccurate
|
||
Reports antenna position accuracy
|
||
stGpsPosPdop
|
||
Reports PDOP assigns a value of accuracy to the calculated position.
|
||
stGpsPosAvg
|
||
Reports position averaging value indicates how many position values are used to determine position.
|
||
"
|
||
INDEX { stGpsPosChassis, stGpsPosSlot}
|
||
::= { stGpsPosTable 1 }
|
||
|
||
|
||
StGpsPosEntry ::=
|
||
SEQUENCE {
|
||
stGpsPosChassis
|
||
INTEGER,
|
||
stGpsPosSlot
|
||
INTEGER,
|
||
stGpsPosValid
|
||
ValidValue,
|
||
stGpsPosLat
|
||
TLatAndLon,
|
||
stGpsPosLon
|
||
TLatAndLon,
|
||
stGpsPosHgt
|
||
TAntHeight,
|
||
stGpsPosAccurate
|
||
INTEGER,
|
||
stGpsPosPdop
|
||
INTEGER,
|
||
stGpsPosAvg
|
||
INTEGER
|
||
}
|
||
|
||
stGpsPosChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which shelf is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { stGpsPosEntry 1 }
|
||
|
||
stGpsPosSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { stGpsPosEntry 2 }
|
||
|
||
stGpsPosValid OBJECT-TYPE
|
||
SYNTAX ValidValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if the GPS position is valid or not.
|
||
|
||
1 = valid
|
||
2 = invalid
|
||
"
|
||
::= { stGpsPosEntry 3 }
|
||
|
||
stGpsPosLat OBJECT-TYPE
|
||
SYNTAX TLatAndLon
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports antenna latitude position of the GPS module.
|
||
|
||
The format is +dd:mm:ss.ss or -dd:mm:ss.ss
|
||
The latitude is +/- 90 deg.
|
||
"
|
||
::= { stGpsPosEntry 4 }
|
||
|
||
stGpsPosLon OBJECT-TYPE
|
||
SYNTAX TLatAndLon
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports antenna longitude position of the GPS module.
|
||
|
||
The format is +dd:mm:ss.ss or -dd:mm:ss.ss
|
||
The longitude is +/- 180 deg.
|
||
"
|
||
::= { stGpsPosEntry 5 }
|
||
|
||
stGpsPosHgt OBJECT-TYPE
|
||
SYNTAX TAntHeight
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports antenna height (meter) position of the GPS module.
|
||
|
||
The format is +hh.hh or -hh.hh
|
||
The height is +/- 10000.0 meters.
|
||
"
|
||
::= { stGpsPosEntry 6 }
|
||
|
||
stGpsPosAccurate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
approx (1),
|
||
d2 (2),
|
||
d3 (3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports antenna position accuracy
|
||
APPROX - position is not accurate
|
||
D2 - position is accurate, 2D, height is not valid
|
||
D3 - position is accurate, 3D, height is valid
|
||
"
|
||
::= { stGpsPosEntry 7 }
|
||
|
||
stGpsPosPdop OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports PDOP indicates position precision as an integer representation of value in tenths.
|
||
For example, the value 19 means 1.9 pdop.
|
||
if zero, it means invalid.
|
||
"
|
||
::= { stGpsPosEntry 8 }
|
||
|
||
stGpsPosAvg OBJECT-TYPE
|
||
SYNTAX INTEGER (0..3600)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports satellite position averaging value.
|
||
If zero, the satellite position is user entered.
|
||
"
|
||
::= { stGpsPosEntry 9 }
|
||
|
||
|
||
-- ******************************************
|
||
-- GPS AVAILABILITY TABLE
|
||
-- ******************************************
|
||
|
||
stGpsAvailTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StGpsAvEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of GPS satellite availability, reports the location of visible satellites.
|
||
"
|
||
::= { statusGps 3 }
|
||
|
||
|
||
stGpsAvEntry OBJECT-TYPE
|
||
SYNTAX StGpsAvEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"GPS Availability attributes:
|
||
"
|
||
INDEX { stGpsAvChassis, stGpsAvSlot, stGpsAvChnl}
|
||
::= { stGpsAvailTable 1 }
|
||
|
||
|
||
StGpsAvEntry ::=
|
||
SEQUENCE {
|
||
stGpsAvChassis
|
||
INTEGER,
|
||
stGpsAvSlot
|
||
INTEGER,
|
||
stGpsAvChnl
|
||
INTEGER,
|
||
stGpsAvPNCode
|
||
INTEGER,
|
||
stGpsAvElevation
|
||
INTEGER,
|
||
stGpsAvAzimuth
|
||
INTEGER,
|
||
stGpsAvHealthy
|
||
YesValue
|
||
}
|
||
|
||
|
||
stGpsAvChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { stGpsAvEntry 1 }
|
||
|
||
stGpsAvSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { stGpsAvEntry 2 }
|
||
|
||
stGpsAvChnl OBJECT-TYPE
|
||
SYNTAX INTEGER (1..32)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports satellite channel number.
|
||
"
|
||
::= { stGpsAvEntry 3 }
|
||
|
||
stGpsAvPNCode OBJECT-TYPE
|
||
SYNTAX INTEGER (0..99)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports satellite PN code.
|
||
"
|
||
::= { stGpsAvEntry 4 }
|
||
|
||
stGpsAvElevation OBJECT-TYPE
|
||
SYNTAX INTEGER (0..90)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports calculated elevation (in degrees) of the satellite.
|
||
"
|
||
::= { stGpsAvEntry 5 }
|
||
|
||
stGpsAvAzimuth OBJECT-TYPE
|
||
SYNTAX INTEGER (0..360)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports calculated Azimuth (in degrees) of the satellite.
|
||
"
|
||
::= { stGpsAvEntry 6 }
|
||
|
||
stGpsAvHealthy OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports current health of the satellite.
|
||
|
||
1 = healthy
|
||
2 = unhealthy
|
||
"
|
||
::= { stGpsAvEntry 7 }
|
||
|
||
|
||
-- ******************************************
|
||
-- GPS TRACKING TABLE
|
||
-- ******************************************
|
||
|
||
stGpsTrackTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StGpsTkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of GPS satellites being tracked show with visibility, signal strength, & health information.
|
||
"
|
||
::= { statusGps 5 }
|
||
|
||
|
||
stGpsTkEntry OBJECT-TYPE
|
||
SYNTAX StGpsTkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A entry GPS attributes.
|
||
"
|
||
INDEX { stGpsTkChassis, stGpsTkSlot, stGpsTkChnl}
|
||
::= { stGpsTrackTable 1 }
|
||
|
||
|
||
StGpsTkEntry ::=
|
||
SEQUENCE {
|
||
stGpsTkChassis
|
||
INTEGER,
|
||
stGpsTkSlot
|
||
INTEGER,
|
||
stGpsTkChnl
|
||
INTEGER,
|
||
stGpsTkSv
|
||
INTEGER,
|
||
stGpsTkSnr
|
||
INTEGER,
|
||
stGpsTkStatus
|
||
INTEGER
|
||
}
|
||
|
||
stGpsTkChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { stGpsTkEntry 1 }
|
||
|
||
stGpsTkSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { stGpsTkEntry 2 }
|
||
|
||
stGpsTkChnl OBJECT-TYPE
|
||
SYNTAX INTEGER (1..32)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports satellite channel number.
|
||
"
|
||
::= { stGpsTkEntry 3 }
|
||
|
||
stGpsTkSv OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..32)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports satellite vehicle number being tracked.
|
||
if zero, it is invalid
|
||
"
|
||
::= { stGpsTkEntry 4 }
|
||
|
||
stGpsTkSnr OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports signal-to-noise ration number being reported
|
||
if zero, it is invalid
|
||
"
|
||
::= { stGpsTkEntry 5 }
|
||
|
||
stGpsTkStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
src (1), -- search
|
||
acq (2), -- acquire
|
||
agc (3), -- automatic gain control
|
||
frq (4), -- frequency locking
|
||
cod (5), -- code locking
|
||
msg (6), -- messaging
|
||
tim (7), -- setting time
|
||
eph (8), -- retriving ephemeris data
|
||
ok (9) -- satellite being used in the timing solution
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports tracking status.
|
||
src (1), -- search
|
||
acq (2), -- acquire
|
||
agc (3), -- automatic gain control
|
||
frq (4), -- frequency locking
|
||
cod (5), -- code locking
|
||
msg (6), -- messaging
|
||
tim (7), -- setting time
|
||
eph (8), -- retriving ephemeris data
|
||
ok (9) -- satellite being used in the timing solution
|
||
"
|
||
::= { stGpsTkEntry 6 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 DS1/E1 INPUT MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staDs1E1InpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaDiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1/E1 Input status entries.
|
||
"
|
||
::= { statusDs1E1Inp 2 }
|
||
|
||
|
||
staDiEntry OBJECT-TYPE
|
||
SYNTAX StaDiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input port status attributes.
|
||
"
|
||
INDEX { staDiChassis, staDiSlot, staDiPort }
|
||
::= { staDs1E1InpTable 1 }
|
||
|
||
StaDiEntry ::=
|
||
SEQUENCE {
|
||
staDiChassis
|
||
INTEGER,
|
||
staDiSlot
|
||
INTEGER,
|
||
staDiPort
|
||
INTEGER,
|
||
|
||
staDiStatus
|
||
INTEGER,
|
||
staDiPhaseA
|
||
INTEGER,
|
||
staDiPhaseB
|
||
INTEGER,
|
||
staDiPql
|
||
INTEGER,
|
||
staDiPqlRcv
|
||
YesValue,
|
||
|
||
-- INPUT HARDWARE SIGNAL STATUS
|
||
staDiLOS
|
||
OkValue,
|
||
staDiAIS
|
||
OkValue,
|
||
staDiOOF
|
||
OkValue,
|
||
staDiBPV
|
||
OkValue,
|
||
staDiCRC
|
||
OkValue,
|
||
|
||
-- MTIE THRESHOLD STATUS
|
||
staDiMtie1A
|
||
INTEGER,
|
||
staDiMtie2A
|
||
INTEGER,
|
||
staDiMtie1B
|
||
INTEGER,
|
||
staDiMtie2B
|
||
INTEGER,
|
||
|
||
-- FREQUENCY THRESHOLD STATUS
|
||
staDiFreqA
|
||
OkValue,
|
||
staDiFreqB
|
||
OkValue,
|
||
|
||
-- INPUT SIGNAL ERROR/CLEAR COUNT
|
||
staLOSErCnt
|
||
Counter32,
|
||
staLOSClCnt
|
||
Counter32,
|
||
staAISErCnt
|
||
Counter32,
|
||
staAISClCnt
|
||
Counter32,
|
||
staOOFErCnt
|
||
Counter32,
|
||
staOOFClCnt
|
||
Counter32,
|
||
staBPVErCnt
|
||
Counter32,
|
||
staBPVClCnt
|
||
Counter32,
|
||
staCRCErCnt
|
||
Counter32,
|
||
staCRCClCnt
|
||
Counter32,
|
||
|
||
-- Module Status
|
||
staDiMStatus
|
||
INTEGER
|
||
}
|
||
|
||
staDiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one.
|
||
(i.e. in the main chassis)
|
||
"
|
||
::= { staDiEntry 1 }
|
||
|
||
staDiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staDiEntry 2 }
|
||
|
||
|
||
staDiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staDiEntry 3 }
|
||
|
||
|
||
staDiStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port status.
|
||
ok(1), -- port is enabled & operating without faults
|
||
selected(2), -- port is selected as system reference
|
||
disable(3), -- port is diabled
|
||
fault(4) -- port is enabled & operating with fault(s)
|
||
"
|
||
::= { staDiEntry 4 }
|
||
|
||
staDiPhaseA OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock A.
|
||
The phaseA is the current 1 second phase value in nanoseconds on clock A.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staDiEntry 5 }
|
||
|
||
staDiPhaseB OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock B.
|
||
The phaseB is the current 1 second phase value in nanoseconds on clock B.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staDiEntry 6 }
|
||
|
||
staDiPql OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port Priority Quality Level (PQL).
|
||
The PQL is the current stratum level (read or provisioned) being reported by the port.
|
||
If zero, it is invalid.
|
||
"
|
||
::= { staDiEntry 7 }
|
||
|
||
staDiPqlRcv OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports receiving Sync Status Message (SSM) for the input port state.
|
||
|
||
1 = enabled
|
||
2 = disabled
|
||
"
|
||
::= { staDiEntry 8 }
|
||
|
||
|
||
staDiLOS OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has LOS fault.
|
||
"
|
||
::= { staDiEntry 9 }
|
||
|
||
staDiAIS OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has AIS fault.
|
||
"
|
||
::= { staDiEntry 10 }
|
||
|
||
staDiOOF OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has OOF fault.
|
||
"
|
||
::= { staDiEntry 11 }
|
||
|
||
|
||
staDiBPV OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has BPV fault.
|
||
"
|
||
::= { staDiEntry 12 }
|
||
|
||
|
||
staDiCRC OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port CRC fault.
|
||
"
|
||
::= { staDiEntry 13 }
|
||
|
||
|
||
staDiMtie1A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded versus clock A.
|
||
|
||
If ok, it means no error for MTIE limit 1 on clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded versus clock A.
|
||
"
|
||
::= { staDiEntry 14 }
|
||
|
||
staDiMtie2A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded versus clock A.
|
||
|
||
If ok, it means no error for MTIE limit 2 versus clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded versus clock A.
|
||
"
|
||
::= { staDiEntry 15 }
|
||
|
||
|
||
staDiMtie1B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded verus clock B.
|
||
|
||
If ok, it means no error for MTIE limit 1 versus clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded versus clock B.
|
||
"
|
||
::= { staDiEntry 16 }
|
||
|
||
|
||
staDiMtie2B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded versus clock B.
|
||
|
||
If ok, it means no error for MTIE limit 2 versus clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded versus clock B.
|
||
"
|
||
::= { staDiEntry 17 }
|
||
|
||
|
||
staDiFreqA OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port frequency threshold exceeded versus clock A.
|
||
"
|
||
::= { staDiEntry 18 }
|
||
|
||
|
||
staDiFreqB OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port frequency threshold exceeded versus clock B.
|
||
"
|
||
::= { staDiEntry 19 }
|
||
|
||
|
||
staLOSErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port LOS error count.
|
||
"
|
||
::= { staDiEntry 20 }
|
||
|
||
|
||
staLOSClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port LOS clear count.
|
||
"
|
||
::= { staDiEntry 21 }
|
||
|
||
|
||
staAISErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port AIS error count.
|
||
"
|
||
::= { staDiEntry 22 }
|
||
|
||
|
||
staAISClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port AIS clear count.
|
||
"
|
||
::= { staDiEntry 23 }
|
||
|
||
|
||
staOOFErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port OOF error count.
|
||
"
|
||
::= { staDiEntry 24 }
|
||
|
||
|
||
staOOFClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port OOF clear count.
|
||
"
|
||
::= { staDiEntry 25 }
|
||
|
||
|
||
staBPVErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port BPV error count.
|
||
"
|
||
::= { staDiEntry 26 }
|
||
|
||
|
||
staBPVClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port BPV clear count.
|
||
"
|
||
::= { staDiEntry 27 }
|
||
|
||
|
||
staCRCErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port CRC error count.
|
||
"
|
||
::= { staDiEntry 28 }
|
||
|
||
|
||
staCRCClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port CRC clear count.
|
||
"
|
||
::= { staDiEntry 29 }
|
||
|
||
|
||
staDiMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(2),
|
||
fault(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The input module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(2), -- module is disabled
|
||
fault(3) -- module is enabled and operating with fault(s)
|
||
"
|
||
::= { staDiEntry 30 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 COMPOSITE CLOCK INPUT MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staCcInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaCiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Composite Clock Input status information.
|
||
"
|
||
::= { statusCcInp 2 }
|
||
|
||
|
||
staCiEntry OBJECT-TYPE
|
||
SYNTAX StaCiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input port status attributes.
|
||
"
|
||
INDEX { staCiChassis, staCiSlot, staCiPort }
|
||
::= { staCcInpTable 1 }
|
||
|
||
StaCiEntry ::=
|
||
SEQUENCE {
|
||
staCiChassis
|
||
INTEGER,
|
||
staCiSlot
|
||
INTEGER,
|
||
staCiPort
|
||
INTEGER,
|
||
|
||
staCiStatus
|
||
INTEGER,
|
||
staCiPhaseA
|
||
INTEGER,
|
||
staCiPhaseB
|
||
INTEGER,
|
||
|
||
-- INPUT HARDWARE SIGNAL STATUS
|
||
staCiLOS
|
||
OkValue,
|
||
staCiBPV
|
||
OkValue,
|
||
|
||
-- INPUT SIGNAL ERROR/CLEAR COUNT
|
||
staCiLOSErCnt
|
||
Counter32,
|
||
staCiLOSClCnt
|
||
Counter32,
|
||
staCiBPVErCnt
|
||
Counter32,
|
||
staCiBPVClCnt
|
||
Counter32,
|
||
|
||
-- Module Status
|
||
staCiMStatus
|
||
INTEGER
|
||
}
|
||
|
||
staCiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one.
|
||
(i.e. in the main chassis)
|
||
"
|
||
::= { staCiEntry 1 }
|
||
|
||
staCiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staCiEntry 2 }
|
||
|
||
|
||
staCiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staCiEntry 3 }
|
||
|
||
|
||
staCiStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port status.
|
||
ok(1), -- port is enabled & operating without faults
|
||
selected(2), -- port is selected as system reference
|
||
disable(3), -- port is diabled
|
||
fault(4) -- port is enabled & operating with fault(s)
|
||
"
|
||
::= { staCiEntry 4 }
|
||
|
||
staCiPhaseA OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock A.
|
||
The phaseA is the current 1 second phase value in nanoseconds on clock A.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staCiEntry 5 }
|
||
|
||
staCiPhaseB OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock B.
|
||
The phaseB is the current 1 second phase value in nanoseconds on clock B.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staCiEntry 6 }
|
||
|
||
staCiLOS OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has LOS fault.
|
||
"
|
||
::= { staCiEntry 9 }
|
||
|
||
staCiBPV OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has BPV fault.
|
||
"
|
||
::= { staCiEntry 12 }
|
||
|
||
staCiLOSErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port LOS error count.
|
||
"
|
||
::= { staCiEntry 14 }
|
||
|
||
|
||
staCiLOSClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port LOS clear count.
|
||
"
|
||
::= { staCiEntry 15 }
|
||
|
||
staCiBPVErCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port BPV error count.
|
||
"
|
||
::= { staCiEntry 20 }
|
||
|
||
|
||
staCiBPVClCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port BPV clear count.
|
||
"
|
||
::= { staCiEntry 21 }
|
||
|
||
staCiMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(2),
|
||
fault(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(2), -- module is disabled
|
||
fault(3) -- module is enabled and operating with fault(s)
|
||
"
|
||
::= { staCiEntry 24 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 SINE INPUT MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staSineInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaSineiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Sine Input status information.
|
||
"
|
||
::= { statusSineInp 2 }
|
||
|
||
|
||
staSineiEntry OBJECT-TYPE
|
||
SYNTAX StaSineiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input port status attributes.
|
||
"
|
||
INDEX { staSineiChassis, staSineiSlot, staSineiPort }
|
||
::= { staSineInpTable 1 }
|
||
|
||
StaSineiEntry ::=
|
||
SEQUENCE {
|
||
staSineiChassis
|
||
INTEGER,
|
||
staSineiSlot
|
||
INTEGER,
|
||
staSineiPort
|
||
INTEGER,
|
||
|
||
staSineiStatus
|
||
INTEGER,
|
||
staSineiPhaseA
|
||
INTEGER,
|
||
staSineiPhaseB
|
||
INTEGER,
|
||
|
||
-- INPUT HARDWARE SIGNAL STATUS
|
||
staSineiLOS
|
||
OkValue,
|
||
|
||
-- Module Status
|
||
staSineiMStatus
|
||
INTEGER,
|
||
|
||
staSineiPql
|
||
INTEGER,
|
||
|
||
-- MTIE THRESHOLD STATUS
|
||
staSineiMtie1A
|
||
INTEGER,
|
||
staSineiMtie2A
|
||
INTEGER,
|
||
staSineiMtie1B
|
||
INTEGER,
|
||
staSineiMtie2B
|
||
INTEGER,
|
||
|
||
-- FREQUENCY THRESHOLD STATUS
|
||
staSineiFreqA
|
||
OkValue,
|
||
staSineiFreqB
|
||
OkValue
|
||
}
|
||
|
||
staSineiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one.
|
||
(i.e. in the main chassis)
|
||
"
|
||
::= { staSineiEntry 1 }
|
||
|
||
staSineiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staSineiEntry 2 }
|
||
|
||
|
||
staSineiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staSineiEntry 3 }
|
||
|
||
|
||
staSineiStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port status.
|
||
ok(1), -- port is enabled & operating without faults
|
||
selected(2), -- port is selected as system reference
|
||
disable(3), -- port is diabled
|
||
fault(4) -- port is enabled & operating with fault(s)
|
||
"
|
||
::= { staSineiEntry 4 }
|
||
|
||
staSineiPhaseA OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock A.
|
||
The phaseA is the current 1 second phase value in nanoseconds on clock A.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staSineiEntry 5 }
|
||
|
||
staSineiPhaseB OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock B.
|
||
The phaseB is the current 1 second phase value in nanoseconds on clock B.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staSineiEntry 6 }
|
||
|
||
staSineiLOS OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has LOS fault.
|
||
"
|
||
::= { staSineiEntry 7 }
|
||
|
||
staSineiMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(2),
|
||
fault(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(2), -- module is disabled
|
||
fault(3) -- module is enabled and operating with fault(s)
|
||
"
|
||
::= { staSineiEntry 8 }
|
||
|
||
staSineiPql OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port Priority Quality Level (PQL).
|
||
The PQL is the current stratum level (read or provisioned) being reported by the port.
|
||
If zero, it is invalid.
|
||
"
|
||
::= { staSineiEntry 9 }
|
||
|
||
staSineiMtie1A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded versus clock A.
|
||
|
||
If ok, it means no error for MTIE limit 1 on clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded versus clock A.
|
||
"
|
||
::= { staSineiEntry 10 }
|
||
|
||
staSineiMtie2A OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded versus clock A.
|
||
|
||
If ok, it means no error for MTIE limit 2 versus clock A.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded versus clock A.
|
||
"
|
||
::= { staSineiEntry 11 }
|
||
|
||
|
||
staSineiMtie1B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 1 threshold was exceeded verus clock B.
|
||
|
||
If ok, it means no error for MTIE limit 1 versus clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 1 threshold was exceeded versus clock B.
|
||
"
|
||
::= { staSineiEntry 12 }
|
||
|
||
|
||
staSineiMtie2B OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
mtie10(10),
|
||
mtie100(100),
|
||
mtie1000(1000),
|
||
mtie10000(10000),
|
||
mtie100000(100000)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which MTIE limit 2 threshold was exceeded versus clock B.
|
||
|
||
If ok, it means no error for MTIE limit 2 versus clock B.
|
||
If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds
|
||
MTIE limit 2 threshold was exceeded versus clock B.
|
||
"
|
||
::= { staSineiEntry 13 }
|
||
|
||
|
||
staSineiFreqA OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port frequency threshold exceeded versus clock A.
|
||
"
|
||
::= { staSineiEntry 14 }
|
||
|
||
|
||
staSineiFreqB OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port frequency threshold exceeded versus clock B.
|
||
"
|
||
::= { staSineiEntry 15 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 JAPANESE COMPOSITE CLOCK INPUT MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staJccInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaJcciEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Composite Clock Input status information.
|
||
"
|
||
::= { statusJccInp 2 }
|
||
|
||
|
||
staJcciEntry OBJECT-TYPE
|
||
SYNTAX StaJcciEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input port status attributes.
|
||
"
|
||
INDEX { staCiChassis, staCiSlot, staCiPort }
|
||
::= { staJccInpTable 1 }
|
||
|
||
StaJcciEntry ::=
|
||
SEQUENCE {
|
||
staJcciChassis
|
||
INTEGER,
|
||
staJcciSlot
|
||
INTEGER,
|
||
staJcciPort
|
||
INTEGER,
|
||
|
||
staJcciStatus
|
||
INTEGER,
|
||
staJcciPhaseA
|
||
INTEGER,
|
||
staJcciPhaseB
|
||
INTEGER,
|
||
|
||
-- INPUT HARDWARE SIGNAL STATUS
|
||
staJcciLOS
|
||
OkValue,
|
||
staJcciBPV
|
||
OkValue,
|
||
staJcci400Hz
|
||
OnValue,
|
||
|
||
-- Module Status
|
||
staJcciMStatus
|
||
INTEGER
|
||
}
|
||
|
||
staJcciChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one.
|
||
(i.e. in the main chassis)
|
||
"
|
||
::= { staJcciEntry 1 }
|
||
|
||
staJcciSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staJcciEntry 2 }
|
||
|
||
|
||
staJcciPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { staJcciEntry 3 }
|
||
|
||
|
||
staJcciStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
selected(2),
|
||
disable(3),
|
||
fault(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port status.
|
||
ok(1), -- port is enabled & operating without faults
|
||
selected(2), -- port is selected as system reference
|
||
disable(3), -- port is diabled
|
||
fault(4) -- port is enabled & operating with fault(s)
|
||
"
|
||
::= { staJcciEntry 4 }
|
||
|
||
staJcciPhaseA OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock A.
|
||
The phaseA is the current 1 second phase value in nanoseconds on clock A.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staJcciEntry 5 }
|
||
|
||
staJcciPhaseB OBJECT-TYPE
|
||
SYNTAX INTEGER (-1999999998..1999999998 | 1999999999)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input phase value versus clock B.
|
||
The phaseB is the current 1 second phase value in nanoseconds on clock B.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
"
|
||
::= { staJcciEntry 6 }
|
||
|
||
staJcciLOS OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has LOS fault.
|
||
"
|
||
::= { staJcciEntry 7 }
|
||
|
||
staJcciBPV OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has BPV fault.
|
||
"
|
||
::= { staJcciEntry 8 }
|
||
|
||
staJcci400Hz OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input port has 400Hz Sync Signal or not.
|
||
"
|
||
::= { staJcciEntry 9 }
|
||
|
||
staJcciMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(2),
|
||
fault(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports input module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(2), -- module is disabled
|
||
fault(3) -- module is enabled and operating with fault(s)
|
||
"
|
||
::= { staJcciEntry 10 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 OUTPUT MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staOutTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaOtEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The list of Generic Output status information.
|
||
"
|
||
::= { statusOut 2 }
|
||
|
||
|
||
staOtEntry OBJECT-TYPE
|
||
SYNTAX StaOtEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Output port status attributes.
|
||
"
|
||
INDEX { staOtChassis, staOtSlot}
|
||
::= { staOutTable 1 }
|
||
|
||
StaOtEntry ::=
|
||
SEQUENCE {
|
||
staOtChassis
|
||
INTEGER,
|
||
staOtSlot
|
||
INTEGER,
|
||
staOtStatus
|
||
INTEGER,
|
||
staOtClkSel
|
||
INTEGER,
|
||
staOtClka
|
||
ActiveValue,
|
||
staOtClkb
|
||
ActiveValue,
|
||
staOtClkc
|
||
ActiveValue,
|
||
staOtClkd
|
||
ActiveValue,
|
||
staOtRednt
|
||
INTEGER,
|
||
staOtPql
|
||
INTEGER,
|
||
staOtPortSta
|
||
OCTET STRING
|
||
}
|
||
|
||
staOtChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which shelf is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The output module can reside on any chassis (1-5).
|
||
"
|
||
::= { staOtEntry 1 }
|
||
|
||
staOtSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staOtEntry 2 }
|
||
|
||
|
||
staOtStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(3),
|
||
fault(4),
|
||
reject(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports output port status.
|
||
ok(1), -- modlule is enabled & operating without faults
|
||
disable(3), -- module is diabled
|
||
fault(4) -- module is enabled & operating with fault(s)
|
||
reject(5) -- module type is mismatched with redundant module
|
||
"
|
||
::= { staOtEntry 3 }
|
||
|
||
staOtClkSel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
clkc(3),
|
||
clkd(4),
|
||
none(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock is selected for generating the output.
|
||
clka(1), -- Clock A is selected as the Primary clock
|
||
clkb(2), -- Clock B is selected as the Primary clock
|
||
clkc(3), -- Clock C is selected as the Primary clock
|
||
clkd(4), -- Clock D is selected as the Primary clock
|
||
none(5) -- no clock is selected
|
||
"
|
||
::= { staOtEntry 4 }
|
||
|
||
staOtClka OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock A is available.
|
||
"
|
||
::= { staOtEntry 5 }
|
||
|
||
staOtClkb OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock B is available.
|
||
"
|
||
::= { staOtEntry 6 }
|
||
|
||
staOtClkc OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock C is available.
|
||
"
|
||
::= { staOtEntry 7 }
|
||
|
||
staOtClkd OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock D is available.
|
||
"
|
||
::= { staOtEntry 8 }
|
||
|
||
|
||
staOtRednt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..20)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the adjacent slot number if this module is the output module redundant pair.
|
||
If this module is not redundant, zero is reported.
|
||
"
|
||
::= { staOtEntry 9 }
|
||
|
||
staOtPql OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the Priority Quality Level (PQL) being generated.
|
||
If zero, it is invalid or Not Applicable.
|
||
"
|
||
::= { staOtEntry 10 }
|
||
|
||
staOtPortSta OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the status for ports 1-20.
|
||
1st digit represents port 1, 20th digit represents port 20
|
||
1 = ok
|
||
2 = not used
|
||
3 = internal port fault
|
||
4 = external port fault
|
||
5 = fault
|
||
6 = squelch
|
||
"
|
||
::= { staOtEntry 11 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 DS1 LRM MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
staLrmMTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaLrmMEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1 LRM module status information.
|
||
"
|
||
::= { statusLrm 2 }
|
||
|
||
|
||
staLrmMEntry OBJECT-TYPE
|
||
SYNTAX StaLrmMEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"DS1 LRM module status attributes.
|
||
"
|
||
INDEX { staLrmMChassis, staLrmMSlot}
|
||
::= { staLrmMTable 1 }
|
||
|
||
StaLrmMEntry ::=
|
||
SEQUENCE {
|
||
staLrmMChassis
|
||
INTEGER,
|
||
staLrmMSlot
|
||
INTEGER,
|
||
staLrmMStatus
|
||
INTEGER,
|
||
staLrmMRefSrc
|
||
INTEGER,
|
||
staLrmMCtaId
|
||
INTEGER
|
||
}
|
||
|
||
staLrmMChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which shelf is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The output module can reside on any chassis (1-5).
|
||
"
|
||
::= { staLrmMEntry 1 }
|
||
|
||
staLrmMSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrmMEntry 2 }
|
||
|
||
staLrmMStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the LRM module state.
|
||
enable(1), -- module is enabled
|
||
disable(2), -- module is disabled
|
||
"
|
||
::= { staLrmMEntry 3 }
|
||
|
||
staLrmMRefSrc OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
clkc(3),
|
||
clkd(4),
|
||
none(5),
|
||
pllflt(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock is selected for generating the output and status.
|
||
clka(1), -- clock A is selected
|
||
clkb(2), -- clock B is selected
|
||
clkc(3), -- clock C is selected
|
||
clkd(4), -- clock D is selected
|
||
none(5), -- no clock is selected
|
||
pllflt(6) -- clock selected, but module's clock PLL is unlocked
|
||
"
|
||
::= { staLrmMEntry 4 }
|
||
|
||
staLrmMCtaId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
dual(1),
|
||
quad(2),
|
||
none(3),
|
||
unknown(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if CTA is installed or not, if installed it reports which type, 2 ports or quad (4) ports.
|
||
If not installed, none is shown.
|
||
If id is not recognized, unknown is shown.
|
||
"
|
||
::= { staLrmMEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 DS1 LRM PORT STATUS GROUP
|
||
-- **************************************************************
|
||
staLrmPTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaLrmPEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1 LRM port status information.
|
||
"
|
||
::= { statusLrm 3 }
|
||
|
||
|
||
staLrmPEntry OBJECT-TYPE
|
||
SYNTAX StaLrmPEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"DS1 LRM module status attributes.
|
||
"
|
||
INDEX { staLrmPChassis, staLrmPSlot, staLrmPPort}
|
||
::= { staLrmPTable 1 }
|
||
|
||
StaLrmPEntry ::=
|
||
SEQUENCE {
|
||
staLrmPChassis
|
||
INTEGER,
|
||
staLrmPSlot
|
||
INTEGER,
|
||
staLrmPPort
|
||
INTEGER,
|
||
staLrmPStatus
|
||
INTEGER,
|
||
staLrmPFrame
|
||
INTEGER,
|
||
staLrmPLos
|
||
OkValue,
|
||
staLrmPAis
|
||
OkValue,
|
||
staLrmPLof
|
||
OkValue,
|
||
staLrmPBpv
|
||
OkValue,
|
||
staLrmPSlip
|
||
OkValue,
|
||
staLrmPSlips
|
||
Counter32,
|
||
staLrmPLosSide2
|
||
OkValue,
|
||
staLrmPBpvTestTime
|
||
Counter32,
|
||
staLrmPBpv60SRate
|
||
DisplayString,
|
||
staLrmPBpv24HRate
|
||
DisplayString,
|
||
staLrmPBpvErrSecs
|
||
Counter32,
|
||
staLrmPBpvSevErrSecs
|
||
Counter32,
|
||
staLrmPBpvSevErrRatio
|
||
DisplayString
|
||
}
|
||
|
||
staLrmPChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The output module can reside on any chassis (1-5).
|
||
"
|
||
::= { staLrmPEntry 1 }
|
||
|
||
staLrmPSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrmPEntry 2 }
|
||
|
||
staLrmPPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrmPEntry 3 }
|
||
|
||
staLrmPStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1), -- port is functioning
|
||
cut(2), -- port is in cut-through mode
|
||
disable(3) -- port is disabled
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port status.
|
||
ok(1), -- port is functioning
|
||
cut(2), -- port is in cut-through mode
|
||
disable(3) -- port is disabled
|
||
"
|
||
::= { staLrmPEntry 4 }
|
||
|
||
staLrmPFrame OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
d4(1), -- D4 signal
|
||
esf(2), -- ESF signal
|
||
none(3) -- indicate Loss Of Frame
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port frame status.
|
||
d4(1), -- D4 signal
|
||
esf(2), -- ESF signal
|
||
none(3) -- indicate Loss Of Frame
|
||
"
|
||
::= { staLrmPEntry 5 }
|
||
|
||
staLrmPLos OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOS status.
|
||
"
|
||
::= { staLrmPEntry 6 }
|
||
|
||
staLrmPAis OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port AIS status.
|
||
"
|
||
::= { staLrmPEntry 7 }
|
||
|
||
staLrmPLof OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOF status.
|
||
"
|
||
::= { staLrmPEntry 8 }
|
||
|
||
staLrmPBpv OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port BPV status.
|
||
"
|
||
::= { staLrmPEntry 9 }
|
||
|
||
staLrmPSlip OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port SLIP status.
|
||
If over the past 24 hours period, the slip count exceeds the threshold, the slip alarm is set.
|
||
"
|
||
::= { staLrmPEntry 10 }
|
||
|
||
staLrmPSlips OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port slip counts.
|
||
"
|
||
::= { staLrmPEntry 11 }
|
||
|
||
staLrmPLosSide2 OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOS on SIDE2 status.
|
||
"
|
||
::= { staLrmPEntry 12 }
|
||
|
||
staLrmPBpvTestTime OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports length of time (in seconds) the BPV has been under tested.
|
||
"
|
||
::= { staLrmPEntry 13 }
|
||
|
||
staLrmPBpv60SRate OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports BPV Error Rate per second in 60-second window.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrmPEntry 14 }
|
||
|
||
staLrmPBpv24HRate OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports BPV Error Rate per second in 86400-second (24 hours) window.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrmPEntry 15 }
|
||
|
||
staLrmPBpvErrSecs OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports accumulated BPV Errored Seconds.
|
||
"
|
||
::= { staLrmPEntry 16 }
|
||
|
||
staLrmPBpvSevErrSecs OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports accumulated BPV Severely Errored Seconds.
|
||
"
|
||
::= { staLrmPEntry 17 }
|
||
|
||
staLrmPBpvSevErrRatio OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports BPV Severely Error Ratio.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrmPEntry 18 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 E1 LRM MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
staLrme1MTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaLrme1MEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of E1 LRM port status information.
|
||
"
|
||
::= { statusLrmE1 2 }
|
||
|
||
|
||
staLrme1MEntry OBJECT-TYPE
|
||
SYNTAX StaLrme1MEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"E1 LRM module status attributes.
|
||
"
|
||
INDEX { staLrme1MChassis, staLrme1MSlot}
|
||
::= { staLrme1MTable 1 }
|
||
|
||
StaLrme1MEntry ::=
|
||
SEQUENCE {
|
||
staLrme1MChassis
|
||
INTEGER,
|
||
staLrme1MSlot
|
||
INTEGER,
|
||
staLrme1MStatus
|
||
INTEGER,
|
||
staLrme1MRefSrc
|
||
INTEGER,
|
||
staLrme1MCtaId
|
||
INTEGER
|
||
}
|
||
|
||
staLrme1MChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The output module can reside on any chassis (1-5).
|
||
"
|
||
::= { staLrme1MEntry 1 }
|
||
|
||
staLrme1MSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrme1MEntry 2 }
|
||
|
||
staLrme1MStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the LRM module state.
|
||
enable(1), -- module is enabled
|
||
disable(2), -- module is disabled
|
||
"
|
||
::= { staLrme1MEntry 3 }
|
||
|
||
staLrme1MRefSrc OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
clkc(3),
|
||
clkd(4),
|
||
none(5),
|
||
pllflt(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock is selected for generating the output and status.
|
||
clka(1), -- clock A is selected
|
||
clkb(2), -- clock B is selected
|
||
clkc(3), -- clock C is selected
|
||
clkd(4), -- clock D is selected
|
||
none(5), -- no clock is selected
|
||
pllflt(6) -- clock selected, but module's clock PLL is unlocked
|
||
"
|
||
::= { staLrme1MEntry 4 }
|
||
|
||
staLrme1MCtaId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
dual(1),
|
||
quad(2),
|
||
none(3),
|
||
unknown(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if CTA is installed or not.
|
||
If installed it reports which type, 2 ports or quad (4) ports.
|
||
If not installed, none is shown.
|
||
If id is not recognized, unknown is shown.
|
||
"
|
||
::= { staLrme1MEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 E1 LRM PORT STATUS GROUP
|
||
-- **************************************************************
|
||
staLrme1PTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaLrme1PEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of E1 LRM port status information.
|
||
"
|
||
::= { statusLrmE1 3 }
|
||
|
||
|
||
staLrme1PEntry OBJECT-TYPE
|
||
SYNTAX StaLrme1PEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"E1 LRM module status attributes.
|
||
"
|
||
INDEX { staLrme1PChassis, staLrme1PSlot, staLrme1PPort}
|
||
::= { staLrme1PTable 1 }
|
||
|
||
StaLrme1PEntry ::=
|
||
SEQUENCE {
|
||
staLrme1PChassis
|
||
INTEGER,
|
||
staLrme1PSlot
|
||
INTEGER,
|
||
staLrme1PPort
|
||
INTEGER,
|
||
staLrme1PStatus
|
||
INTEGER,
|
||
staLrme1PFrame
|
||
OnValue,
|
||
staLrme1PLos
|
||
OkValue,
|
||
staLrme1PAis
|
||
OkValue,
|
||
staLrme1PLof
|
||
OkValue,
|
||
staLrme1PBpv
|
||
OkValue,
|
||
staLrme1PSlip
|
||
OkValue,
|
||
staLrme1PSlips
|
||
Counter32,
|
||
staLrme1PLosSide2
|
||
OkValue,
|
||
staLrme1PBpv60SRate
|
||
DisplayString,
|
||
staLrme1PBpv24HRate
|
||
DisplayString,
|
||
staLrme1PBpvErrSecs
|
||
Counter32,
|
||
staLrme1PBpvSevErrSecs
|
||
Counter32,
|
||
staLrme1PBpvSevErrRatio
|
||
DisplayString
|
||
}
|
||
|
||
staLrme1PChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The output module can reside on any chassis (1-5).
|
||
"
|
||
::= { staLrme1PEntry 1 }
|
||
|
||
staLrme1PSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrme1PEntry 2 }
|
||
|
||
staLrme1PPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staLrme1PEntry 3 }
|
||
|
||
staLrme1PStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1), -- port is functioning
|
||
cut(2), -- port is in cut-through mode
|
||
disable(3) -- port is disabled
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port status.
|
||
ok(1), -- port is functioning
|
||
cut(2), -- port is in cut-through mode
|
||
disable(3) -- port is disabled
|
||
"
|
||
::= { staLrme1PEntry 4 }
|
||
|
||
staLrme1PFrame OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port frame status.
|
||
cas(1), -- CAS signal
|
||
ccs(2), -- CCS signal
|
||
none(3) -- indicate Loss Of Frame
|
||
"
|
||
::= { staLrme1PEntry 5 }
|
||
|
||
staLrme1PLos OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOS status.
|
||
"
|
||
::= { staLrme1PEntry 6 }
|
||
|
||
staLrme1PAis OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port AIS status.
|
||
"
|
||
::= { staLrme1PEntry 7 }
|
||
|
||
staLrme1PLof OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOF status.
|
||
"
|
||
::= { staLrme1PEntry 8 }
|
||
|
||
staLrme1PBpv OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port BPV status.
|
||
"
|
||
::= { staLrme1PEntry 9 }
|
||
|
||
staLrme1PSlip OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port SLIP status.
|
||
If over the past 24 hours period, the slip count exceeds the threshold, the slip alarm is set.
|
||
"
|
||
::= { staLrme1PEntry 10 }
|
||
|
||
staLrme1PSlips OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port slip counts.
|
||
"
|
||
::= { staLrme1PEntry 11 }
|
||
|
||
staLrme1PLosSide2 OBJECT-TYPE
|
||
SYNTAX OkValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports LRM Port LOS on SIDE2 status.
|
||
"
|
||
::= { staLrme1PEntry 12 }
|
||
|
||
staLrme1PBpv60SRate OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports length of time (in seconds) the BPV has been under tested.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrme1PEntry 13 }
|
||
|
||
staLrme1PBpv24HRate OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports BPV Error Rate per second in 86400-second (24 hours) window.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrme1PEntry 14 }
|
||
|
||
staLrme1PBpvErrSecs OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports accumulated BPV Errored Seconds.
|
||
"
|
||
::= { staLrme1PEntry 15 }
|
||
|
||
staLrme1PBpvSevErrSecs OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports accumulated BPV Severely Errored Seconds.
|
||
"
|
||
::= { staLrme1PEntry 16 }
|
||
|
||
staLrme1PBpvSevErrRatio OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports BPV Severely Error Ratio.
|
||
The format is an ascii text string in float number.
|
||
"
|
||
::= { staLrme1PEntry 17 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 PACKETIME NTP MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staPtNtpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaPtNtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PackeTime NTP status information.
|
||
"
|
||
::= { statusPtNtp 1 }
|
||
|
||
|
||
staPtNtpEntry OBJECT-TYPE
|
||
SYNTAX StaPtNtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime NTP status attributes.
|
||
"
|
||
INDEX { staPtNtpChassis, staPtNtpSlot}
|
||
::= { staPtNtpTable 1 }
|
||
|
||
StaPtNtpEntry ::=
|
||
SEQUENCE {
|
||
staPtNtpChassis
|
||
INTEGER,
|
||
staPtNtpSlot
|
||
INTEGER,
|
||
staPtNtpStatus
|
||
INTEGER,
|
||
staPtNtpClkSel
|
||
INTEGER,
|
||
staPtNtpClka
|
||
ActiveValue,
|
||
staPtNtpClkb
|
||
ActiveValue,
|
||
staPtNtpClkc
|
||
ActiveValue,
|
||
staPtNtpClkd
|
||
ActiveValue,
|
||
staPtNtpRednt
|
||
INTEGER,
|
||
staPtNtpModState
|
||
INTEGER,
|
||
staPtNtpPAState
|
||
INTEGER,
|
||
staPtNtpPBState
|
||
INTEGER,
|
||
staPtNtpTod
|
||
OnValue,
|
||
staPtNtpCommit
|
||
INTEGER
|
||
}
|
||
|
||
staPtNtpChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staPtNtpEntry 1 }
|
||
|
||
staPtNtpSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staPtNtpEntry 2 }
|
||
|
||
|
||
staPtNtpStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(3),
|
||
fault(4),
|
||
reject(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The PackeTime NTP module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(3), -- module is disabled
|
||
fault(4), -- module is enabled and operating with fault(s)
|
||
reject(5) -- module type between redundant modules do not agree
|
||
"
|
||
::= { staPtNtpEntry 3 }
|
||
|
||
staPtNtpClkSel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
clkc(3),
|
||
clkd(4),
|
||
none(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock reference is selected to generate the output reference.
|
||
clka(1), -- Clock A is selected as the Primary clock
|
||
clkb(2), -- Clock B is selected as the Primary clock
|
||
clkc(3), -- Clock C is selected as the Primary clock
|
||
clkd(4), -- Clock D is selected as the Primary clock
|
||
none(5) -- no clock is selected
|
||
"
|
||
::= { staPtNtpEntry 4 }
|
||
|
||
staPtNtpClka OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock A is available.
|
||
"
|
||
::= { staPtNtpEntry 5 }
|
||
|
||
staPtNtpClkb OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock B is available.
|
||
"
|
||
::= { staPtNtpEntry 6 }
|
||
|
||
staPtNtpClkc OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock C is available.
|
||
"
|
||
::= { staPtNtpEntry 7 }
|
||
|
||
staPtNtpClkd OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock D is available.
|
||
"
|
||
::= { staPtNtpEntry 8 }
|
||
|
||
staPtNtpRednt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..20)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the adjacent slot number if this module is the redundant pair.
|
||
If this module is not redundant, zero is reported.
|
||
"
|
||
::= { staPtNtpEntry 9 }
|
||
|
||
staPtNtpModState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1),
|
||
stdby(2),
|
||
fault(3),
|
||
stdalone(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current operational mode.
|
||
active(1), --If the module is in redundant pair and selected, it shall return active.
|
||
stdby(2), --If the module is in redundant pair but not selected, it shall return stdby (standby).
|
||
fault(3), --If the module disabled, it will return fault.
|
||
stdalone(4) --If the module is not redundant pair, it shall return stdalone (standalone).
|
||
"
|
||
::= { staPtNtpEntry 10 }
|
||
|
||
staPtNtpPAState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1),
|
||
stdby(2),
|
||
fault(3),
|
||
stdalone(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current operational mode.
|
||
active(1), --If service ports are bonded and selected, it shall return active.
|
||
stdby(2), --If service ports are bonded but not selected, it shall return stdby (standby).
|
||
fault(3), --Service port is faulted.
|
||
stdalone(4) --If service ports are not bonded , it shall return stdalone (standalone).
|
||
"
|
||
::= { staPtNtpEntry 11 }
|
||
|
||
staPtNtpPBState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1),
|
||
stdby(2),
|
||
fault(3),
|
||
stdalone(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current operational mode.
|
||
active(1), --If service ports are bonded and selected, it shall return active.
|
||
stdby(2), --If service ports are bonded but not selected, it shall return stdby (standby).
|
||
fault(3), --Service port is faulted.
|
||
stdalone(4) --If service ports are not bonded , it shall return stdalone (standalone).
|
||
"
|
||
::= { staPtNtpEntry 12 }
|
||
|
||
staPtNtpTod OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if the NTP Time of Day is valid or invalid.
|
||
"
|
||
::= { staPtNtpEntry 13 }
|
||
|
||
staPtNtpCommit OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
done(1),
|
||
prog(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the Commit command status.
|
||
1 = done
|
||
2 = in progress
|
||
"
|
||
::= { staPtNtpEntry 14 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 SETUP GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 COMMUNICATION MODULE SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
setCmId OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (7))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The system identifier, the value is always 'SSU2000'.
|
||
"
|
||
::= { setupCom 1 }
|
||
|
||
setCmInfo OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Symmetricom contact information.
|
||
This displays the Symmetricom address, phone, and fax numbers.
|
||
"
|
||
::= { setupCom 2 }
|
||
|
||
setCmVer OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..100))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports Communication module's software version
|
||
"
|
||
::= { setupCom 3 }
|
||
|
||
setCmName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the user assigned name for the SSU2000.
|
||
|
||
Note: Use caution when changing this, TL1 sessions use the unit name as the target id (tid).
|
||
"
|
||
::= { setupCom 4 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 CLOCK MODULE SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
setClkTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetCkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of clock status and setting information.
|
||
"
|
||
::= { setupClk 1 }
|
||
|
||
|
||
setCkEntry OBJECT-TYPE
|
||
SYNTAX SetCkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clock status and setting attributes.
|
||
"
|
||
INDEX { setCkChassis, setCkSlot}
|
||
::= { setClkTable 1 }
|
||
|
||
SetCkEntry ::=
|
||
SEQUENCE {
|
||
setCkChassis
|
||
INTEGER,
|
||
setCkSlot
|
||
INTEGER,
|
||
setCkWarmup
|
||
INTEGER,
|
||
setCkMinTau
|
||
INTEGER,
|
||
setCkMaxTau
|
||
INTEGER,
|
||
setCkPLLMode
|
||
INTEGER,
|
||
setCkTodTimeout
|
||
INTEGER,
|
||
setCkFreqTimeout
|
||
INTEGER
|
||
}
|
||
|
||
setCkChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setCkEntry 1 }
|
||
|
||
setCkSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This slot number and chassis number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for Clocks are slot 1 and slot 12.
|
||
"
|
||
::= { setCkEntry 2 }
|
||
|
||
setCkWarmup OBJECT-TYPE
|
||
SYNTAX INTEGER (900..3600)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock warmup time in seconds.
|
||
"
|
||
::= { setCkEntry 3 }
|
||
|
||
|
||
setCkMinTau OBJECT-TYPE
|
||
SYNTAX INTEGER (150..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock minimum tau.
|
||
The mintau is the starting time constant value during Locked mode.
|
||
"
|
||
::= { setCkEntry 4 }
|
||
|
||
setCkMaxTau OBJECT-TYPE
|
||
SYNTAX INTEGER (150..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock max tau.
|
||
The maxtau is the final time constant value during Locked mode.
|
||
"
|
||
::= { setCkEntry 5 }
|
||
|
||
|
||
|
||
setCkPLLMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
acq(2),
|
||
lock(3),
|
||
hold(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock operating mode to ACQ/ LOCK/ HOLD.
|
||
Note: When WRITE is to request Clock to change its operating mode, but
|
||
when READ, it returns status of current operating mode. If current is
|
||
operating mode is Warmup, it will return as HOLD.
|
||
"
|
||
::= { setCkEntry 6 }
|
||
|
||
setCkTodTimeout OBJECT-TYPE
|
||
SYNTAX INTEGER (60..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the TODSRC Timeout.
|
||
The TOD Traceability Timeout shall allow the system to operate without a valid
|
||
TOD source for some amount of time before indicating the ToD source is invalid.
|
||
The timer shall have a user settable range from 60 to 10000 minutes,
|
||
with a default value of 1440.
|
||
"
|
||
::= { setCkEntry 7 }
|
||
|
||
setCkFreqTimeout OBJECT-TYPE
|
||
SYNTAX INTEGER (60..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Frequency Timeout.
|
||
The Frequency Traceability Timeout shall allow the system to operate without a valid
|
||
input reference for some amount of time before indicating the frequency source is invalid.
|
||
The timer shall have a user settable range from 60 to 10000 minutes,
|
||
with a default value of 1440.
|
||
"
|
||
::= { setCkEntry 8 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 GPS MODULE SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
setGpsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetGpsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of GPS status and setting information.
|
||
"
|
||
::= { setupGps 1 }
|
||
|
||
setGpsEntry OBJECT-TYPE
|
||
SYNTAX SetGpsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"GPS status and setting attributes.
|
||
"
|
||
INDEX { setGpsChassis, setGpsSlot}
|
||
::= { setGpsTable 1 }
|
||
|
||
|
||
SetGpsEntry ::=
|
||
SEQUENCE {
|
||
setGpsChassis
|
||
INTEGER,
|
||
setGpsSlot
|
||
INTEGER,
|
||
setGpsEngine
|
||
INTEGER,
|
||
setGpsProvPql
|
||
INTEGER,
|
||
setGpsPriority
|
||
INTEGER,
|
||
setGpsPdop
|
||
INTEGER,
|
||
setGpsPosel
|
||
INTEGER,
|
||
setGpsTimel
|
||
INTEGER,
|
||
setGpsAvg
|
||
INTEGER,
|
||
setGpsLat
|
||
TLatAndLon,
|
||
setGpsLon
|
||
TLatAndLon,
|
||
setGpsHgt
|
||
TAntHeight,
|
||
setGpsZeroPhase
|
||
INTEGER,
|
||
setGpsTodsrcPriority
|
||
INTEGER,
|
||
setGpsTodsrcCompensation
|
||
INTEGER,
|
||
setGnssConsMode
|
||
INTEGER
|
||
}
|
||
|
||
setGpsChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setGpsEntry 1 }
|
||
|
||
setGpsSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { setGpsEntry 2 }
|
||
|
||
setGpsEngine OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
na(1),
|
||
unknown(2),
|
||
mot(3),
|
||
nvs(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the GPS engine manufacturer.
|
||
na(1), -- not available
|
||
unknown(2), -- unknown
|
||
mot(3) -- motorola (or motorola compatible)
|
||
nvs(4) -- NVS engine (or GLONASS compatible)
|
||
"
|
||
::= { setGpsEntry 3 }
|
||
|
||
setGpsProvPql OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port provisioned Priority Quality Level (PQL) value.
|
||
Note: Valid values are 1 - 9.
|
||
"
|
||
::= { setGpsEntry 4 }
|
||
|
||
|
||
setGpsPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port priority level.
|
||
The 0 is for monitor-only mode.
|
||
The 1 is the highest priority.
|
||
The 10 is the lowest priority.
|
||
"
|
||
::= { setGpsEntry 5 }
|
||
|
||
setGpsPdop OBJECT-TYPE
|
||
SYNTAX INTEGER (3..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PDOP mask [3 to 10].
|
||
"
|
||
::= { setGpsEntry 6 }
|
||
|
||
setGpsPosel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..90)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the minimum satellite elevation mask for positioning [0 to 90 deg].
|
||
"
|
||
::= { setGpsEntry 7 }
|
||
|
||
setGpsTimel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..90)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the minimum satellite elevation mask for timing [0 to 90 deg].
|
||
"
|
||
::= { setGpsEntry 8 }
|
||
|
||
setGpsAvg OBJECT-TYPE
|
||
SYNTAX INTEGER (20..3600)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set satellite position averaging value [20-3600].
|
||
Mot GPS: (20 - 3600) of averages for the calculated position fixes
|
||
NVS GNSS: (20 - 1440) of averaging minutes
|
||
"
|
||
::= { setGpsEntry 9 }
|
||
|
||
setGpsLat OBJECT-TYPE
|
||
SYNTAX TLatAndLon
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the antenna latitude of the GPS antenna.
|
||
|
||
The format is +dd:mm:ss.ss or -dd:mm:ss.ss
|
||
The latitude is +/- 90 deg.
|
||
"
|
||
::= { setGpsEntry 10 }
|
||
|
||
setGpsLon OBJECT-TYPE
|
||
SYNTAX TLatAndLon
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the antenna longitude of the GPS antenna.
|
||
|
||
The format is +dd:mm:ss.ss or -dd:mm:ss.ss
|
||
The longitude is +/- 180 deg.
|
||
"
|
||
::= { setGpsEntry 11 }
|
||
|
||
setGpsHgt OBJECT-TYPE
|
||
SYNTAX TAntHeight
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the antenna height (meter) of the GPS antenna.
|
||
|
||
The format is +hh.hh or -hh.hh
|
||
The height is +/- 10000.0 meters.
|
||
"
|
||
::= { setGpsEntry 12 }
|
||
|
||
|
||
setGpsZeroPhase OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
zeroPhA(1),
|
||
zeroPhB(2),
|
||
zeroPhAB(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set phase error to zero for this GPS port.
|
||
ZEROPHA - set phase A error to zero,
|
||
ZEROPHB - set phase B error to zero,
|
||
ZEROPHAB - set phase A and B to zero.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
"
|
||
::= { setGpsEntry 13 }
|
||
|
||
|
||
setGpsTodsrcPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the TODSRC (Time-Of-Day Source) priority.
|
||
The priority is the for the specified module as the TOD Source, default is 0, range can be 0 through 8.
|
||
Value 1 is the highest and 8 is the lowest.
|
||
If the value is zero, the specified module cannot be TOD Source.
|
||
"
|
||
::= { setGpsEntry 14 }
|
||
|
||
setGpsTodsrcCompensation OBJECT-TYPE
|
||
SYNTAX INTEGER (0..250)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Antenna cable delay compensation {0 <20> 250} in the case of GPS
|
||
TOD Source(s) or the delay induced by the cable(s) used to connect
|
||
expansion shelves where the PackeTime ToD Source(s) is located in
|
||
relationship to the Main shelf. The time offset shall have a 100nS
|
||
resolution, thus the Delay value shall be multiplied by 100nS to
|
||
provide 1PPS compensation.
|
||
|
||
Valid user compensation values range is 0 thru 250 for a total compensation range of 0 to 25000nS (25uS).
|
||
"
|
||
::= { setGpsEntry 15 }
|
||
|
||
setGnssConsMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
gps(1),
|
||
glonass(2),
|
||
gpsGlonass(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set constellation mode of GNSS engine.
|
||
gps(1), -- The constellation mode of gnss engine is gps.
|
||
glonass(2), -- The constellation mode of gnss engine is glonass
|
||
gpsGlonass(3), -- The constellation mode of gnss engine is gps+glonass.
|
||
"
|
||
::= { setGpsEntry 16 }
|
||
|
||
-- ******************************************
|
||
-- GPS INPUT ALARM THRESHOLD SETTING
|
||
-- ******************************************
|
||
|
||
setAlmThGpsInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetMgEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of GPS input alarm attribute setup information.
|
||
"
|
||
::= { setupGps 2 }
|
||
|
||
|
||
setMgEntry OBJECT-TYPE
|
||
SYNTAX SetMgEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input alarm attributes and settings.
|
||
setMgChassis
|
||
Identifies which chassis is being addressed.
|
||
setMgSlot
|
||
Identifies which slot position is being addressed.
|
||
setMgMtieStd
|
||
Set the input port setting of the MTIE limits to predefined values.
|
||
setMgMtie10EL1
|
||
Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
setMgMtie10EL2
|
||
Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
setMgMtie10CL1
|
||
Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
setMgMtie10CL2
|
||
Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
setMgMtie100EL1
|
||
Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
setMgMtie100EL2
|
||
Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
setMgMtie100CL1
|
||
Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
setMgMtie100CL2
|
||
Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
setMgMtie1000EL1
|
||
Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
setMgMtie1000EL2
|
||
Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
setMgMtie1000CL1
|
||
Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
setMgMtie1000CL2
|
||
Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
setMgMtie10000EL1
|
||
Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
setMgMtie10000EL2
|
||
Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
setMgMtie10000CL1
|
||
Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
setMgMtie10000CL2
|
||
Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
setMgMtie100000EL1
|
||
Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
setMgMtie100000EL2
|
||
Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
setMgMtie100000CL1
|
||
Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
setMgMtie100000CL2
|
||
Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
setMgFreqAErrLmt
|
||
Set the input port frequency error threshold for clock A.
|
||
setMgFreqAClrLmt
|
||
Set the input port frequency clear threshold for clock A.
|
||
setMgFreqATau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A.
|
||
setMgFreqBErrLmt
|
||
Set the input port frequency error threshold for clock B.
|
||
setMgFreqBClrLmt
|
||
Set the input port frequency clear threshold for clock B.
|
||
setMgFreqBTau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
|
||
"
|
||
INDEX { setMgChassis, setMgSlot }
|
||
::= { setAlmThGpsInpTable 1 }
|
||
|
||
|
||
SetMgEntry ::=
|
||
SEQUENCE {
|
||
setMgChassis
|
||
INTEGER,
|
||
setMgSlot
|
||
INTEGER,
|
||
|
||
-- MTIE Threshold Setting
|
||
setMgMtieStd
|
||
INTEGER,
|
||
|
||
setMgMtie10EL1
|
||
INTEGER,
|
||
setMgMtie10EL2
|
||
INTEGER,
|
||
setMgMtie10CL1
|
||
INTEGER,
|
||
setMgMtie10CL2
|
||
INTEGER,
|
||
|
||
setMgMtie100EL1
|
||
INTEGER,
|
||
setMgMtie100EL2
|
||
INTEGER,
|
||
setMgMtie100CL1
|
||
INTEGER,
|
||
setMgMtie100CL2
|
||
INTEGER,
|
||
|
||
setMgMtie1000EL1
|
||
INTEGER,
|
||
setMgMtie1000EL2
|
||
INTEGER,
|
||
setMgMtie1000CL1
|
||
INTEGER,
|
||
setMgMtie1000CL2
|
||
INTEGER,
|
||
|
||
setMgMtie10000EL1
|
||
INTEGER,
|
||
setMgMtie10000EL2
|
||
INTEGER,
|
||
setMgMtie10000CL1
|
||
INTEGER,
|
||
setMgMtie10000CL2
|
||
INTEGER,
|
||
|
||
setMgMtie100000EL1
|
||
INTEGER,
|
||
setMgMtie100000EL2
|
||
INTEGER,
|
||
setMgMtie100000CL1
|
||
INTEGER,
|
||
setMgMtie100000CL2
|
||
INTEGER,
|
||
|
||
-- FREQ Threshold Setting
|
||
setMgFreqAErrLmt
|
||
INTEGER,
|
||
setMgFreqAClrLmt
|
||
INTEGER,
|
||
setMgFreqATau
|
||
INTEGER,
|
||
|
||
setMgFreqBErrLmt
|
||
INTEGER,
|
||
setMgFreqBClrLmt
|
||
INTEGER,
|
||
setMgFreqBTau
|
||
INTEGER
|
||
}
|
||
|
||
|
||
setMgChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setMgEntry 1 }
|
||
|
||
setMgSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
|
||
"
|
||
::= { setMgEntry 2 }
|
||
|
||
setMgMtieStd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
prs(1),
|
||
ds1(2),
|
||
g811(3),
|
||
g823(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port setting of the MTIE limits to predefined values.
|
||
prs(1), -- ANSI T1.101 PRS MTIE MASK
|
||
ds1(2), -- ANSI T1.101 DS1 MTIE MASK
|
||
g811(3), -- G.811 (PRC) MTIE MASK
|
||
g823(4) -- G.823 (SSU) MTIE MASK
|
||
|
||
This field is only meaningful for a write operation.
|
||
"
|
||
::= { setMgEntry 3 }
|
||
|
||
setMgMtie10EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 4 }
|
||
|
||
setMgMtie10EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 5 }
|
||
|
||
setMgMtie10CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 6 }
|
||
|
||
setMgMtie10CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 7 }
|
||
|
||
|
||
setMgMtie100EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 8 }
|
||
|
||
setMgMtie100EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 9 }
|
||
|
||
setMgMtie100CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 10 }
|
||
|
||
setMgMtie100CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 11 }
|
||
|
||
|
||
setMgMtie1000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 12 }
|
||
|
||
setMgMtie1000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 13 }
|
||
|
||
setMgMtie1000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 14 }
|
||
|
||
setMgMtie1000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 15 }
|
||
|
||
setMgMtie10000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 16 }
|
||
|
||
setMgMtie10000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 17 }
|
||
|
||
|
||
setMgMtie10000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 18 }
|
||
|
||
setMgMtie10000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 19 }
|
||
|
||
|
||
setMgMtie100000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 20 }
|
||
|
||
setMgMtie100000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 21 }
|
||
|
||
|
||
setMgMtie100000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMgEntry 22 }
|
||
|
||
setMgMtie100000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMgEntry 23 }
|
||
|
||
setMgFreqAErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency error threshold for clock A.
|
||
"
|
||
::= { setMgEntry 24 }
|
||
|
||
setMgFreqAClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency clear threshold for clock A.
|
||
"
|
||
::= { setMgEntry 25 }
|
||
|
||
setMgFreqATau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A.
|
||
"
|
||
::= { setMgEntry 26 }
|
||
|
||
|
||
setMgFreqBErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency error threshold for clock B.
|
||
"
|
||
::= { setMgEntry 27 }
|
||
|
||
setMgFreqBClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency clear threshold for clock B.
|
||
"
|
||
::= { setMgEntry 28 }
|
||
|
||
setMgFreqBTau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
|
||
"
|
||
::= { setMgEntry 29 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 DS1/E1 INPUT MODULE SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
|
||
-- ******************************************
|
||
-- DS1/E1 INPUT MODULE SETTING
|
||
-- ******************************************
|
||
|
||
setDs1E1InpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetDiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The list of DS1/E1 attribute setup information.
|
||
"
|
||
::= { setupDs1E1Inp 2 }
|
||
|
||
|
||
setDiEntry OBJECT-TYPE
|
||
SYNTAX SetDiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input status and settings attributes.
|
||
"
|
||
INDEX { setDiChassis, setDiSlot, setDiPort }
|
||
::= { setDs1E1InpTable 1 }
|
||
|
||
SetDiEntry ::=
|
||
SEQUENCE {
|
||
setDiChassis
|
||
INTEGER,
|
||
setDiSlot
|
||
INTEGER,
|
||
setDiPort
|
||
INTEGER,
|
||
setDiEnable
|
||
EnaValue,
|
||
setDiFrame
|
||
INTEGER,
|
||
setDiZS
|
||
OnValue,
|
||
setDiCRC
|
||
OnValue,
|
||
setDiSSM
|
||
OnValue,
|
||
setDiProvPql
|
||
INTEGER,
|
||
setDiPriority
|
||
INTEGER,
|
||
setDiGain
|
||
OnValue,
|
||
setDiCSFlt
|
||
INTEGER,
|
||
setDiE1SsmBit
|
||
INTEGER,
|
||
setDiZeroPhase
|
||
INTEGER,
|
||
setDiMtieCalc
|
||
INTEGER
|
||
}
|
||
|
||
setDiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The input module can only reside in chassis 1 (main chassis).
|
||
"
|
||
::= { setDiEntry 1 }
|
||
|
||
setDiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setDiEntry 2 }
|
||
|
||
|
||
setDiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setDiEntry 3 }
|
||
|
||
|
||
setDiEnable OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port to enabled or disabled.
|
||
"
|
||
::= { setDiEntry 4 }
|
||
|
||
|
||
setDiFrame OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
esf(1),
|
||
d4(2),
|
||
ccs(3),
|
||
cas(4),
|
||
mhz1(5),
|
||
khz1544(6),
|
||
khz2048(7),
|
||
mhz5(8),
|
||
mhz10(9)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input framing type or clock frequency.
|
||
esf(1), -- T1 ESF
|
||
d4(2), -- T1 D4
|
||
ccs(3), -- E1 CCS
|
||
cas(4), -- E1 CAS
|
||
mhz1(5), -- Clock 1MHz
|
||
khz1544(6), -- Clock 1544kHz
|
||
khz2048(7), -- Clock 2048kHz
|
||
mhz5(8), -- Clock 5MHz
|
||
mhz10(9) -- Clock 10MHz
|
||
"
|
||
::= { setDiEntry 5 }
|
||
|
||
setDiZS OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Zero Supression (ZS) on the input port to enabled or disabled.
|
||
"
|
||
::= { setDiEntry 6 }
|
||
|
||
setDiCRC OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set CRC verificaiton on the input port to enabled or disabled.
|
||
"
|
||
::= { setDiEntry 7 }
|
||
|
||
setDiSSM OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Sync Status Messaging (SSM) on the input port to enabled or disabled..
|
||
"
|
||
::= { setDiEntry 8 }
|
||
|
||
setDiProvPql OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port provisioned Priority Quality Level (PQL).
|
||
|
||
Note: Valid values are 1 - 9.
|
||
"
|
||
::= { setDiEntry 9 }
|
||
|
||
|
||
setDiPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port priority level.
|
||
'0' = monitoring,
|
||
'1' = highest priority,
|
||
'10' = lowest priority.
|
||
"
|
||
::= { setDiEntry 10 }
|
||
|
||
setDiGain OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port gain setting to enabled or disabled.
|
||
"
|
||
::= { setDiEntry 11 }
|
||
|
||
setDiCSFlt OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
off(1),
|
||
low(2),
|
||
high(3),
|
||
na(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set input Port 1 for external Cesium (CS) fault alarm logic level.
|
||
off(1), -- function is disabled
|
||
low(2), -- function is enabled, will trigger on low (0V) level
|
||
high(3), -- function is enabled, will trigger on high (+5v) level
|
||
na(4) -- not applicable
|
||
|
||
Note: only available for port one.
|
||
"
|
||
::= { setDiEntry 12 }
|
||
|
||
setDiE1SsmBit OBJECT-TYPE
|
||
SYNTAX INTEGER (4..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port E1 Sync Status Message (SSM) bit position.
|
||
|
||
This command is only meaningful for the E1 input module.
|
||
For DS1, this value is always 4, and has no meaning (i.e. not used).
|
||
"
|
||
::= { setDiEntry 13 }
|
||
|
||
|
||
setDiZeroPhase OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
zeroPhA(1),
|
||
zeroPhB(2),
|
||
zeroPhAB(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the phase error to zero for this input port.
|
||
ZEROPHA - set phase A error to zero,
|
||
ZEROPHB - set phase B error to zero,
|
||
ZEROPHAB - set phase A and B to zero.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
"
|
||
::= { setDiEntry 14 }
|
||
|
||
setDiMtieCalc OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
hz40(1),
|
||
hz1(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports MTIE calculator (40Hz or 1Hz) being used
|
||
|
||
The number represents the input port setting for MTIE Calculator measurement.
|
||
- 40Hz - Selects the 40Hz MTIE values to set/clear MTIE alarms
|
||
- 1Hz - Selects the 1Hz MTIE values to set/clear MTIE alarms
|
||
|
||
Note: only available for port one.
|
||
"
|
||
::= { setDiEntry 15 }
|
||
|
||
|
||
-- ******************************************
|
||
-- DS1/E1 INPUT ALARM THRESHOLD SETTING
|
||
-- ******************************************
|
||
|
||
setAlmThDs1E1InpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetMiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1/E1 input alarm attributes and settings information.
|
||
"
|
||
::= { setupDs1E1Inp 4 }
|
||
|
||
|
||
setMiEntry OBJECT-TYPE
|
||
SYNTAX SetMiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input alarm attributes and settings.
|
||
setMiChassis
|
||
Identifies which chassis is being addressed.
|
||
setMiSlot
|
||
Identifies which slot position is being addressed.
|
||
setMiPort
|
||
Identifies which port position is being addressed.
|
||
setMiMtieStd
|
||
Set the input port setting of the MTIE limits to predefined values.
|
||
setMiMtie10EL1
|
||
Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
setMiMtie10EL2
|
||
Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
setMiMtie10CL1
|
||
Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
setMiMtie10CL2
|
||
Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
setMiMtie100EL1
|
||
Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
setMiMtie100EL2
|
||
Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
setMiMtie100CL1
|
||
Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
setMiMtie100CL2
|
||
Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
setMiMtie1000EL1
|
||
Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
setMiMtie1000EL2
|
||
Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
setMiMtie1000CL1
|
||
Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
setMiMtie1000CL2
|
||
Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
setMiMtie10000EL1
|
||
Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
setMiMtie10000EL2
|
||
Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
setMiMtie10000CL1
|
||
Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
setMiMtie10000CL2
|
||
Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
setMiMtie100000EL1
|
||
Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
setMiMtie100000EL2
|
||
Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
setMiMtie100000CL1
|
||
Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
setMiMtie100000CL2
|
||
Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
setMiFreqAErrLmt
|
||
Set the input port frequency error threshold for clock A.
|
||
setMiFreqAClrLmt
|
||
Set the input port frequency clear threshold for clock A.
|
||
setMiFreqATau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A.
|
||
setMiFreqBErrLmt
|
||
Set the input port frequency error threshold for clock B.
|
||
setMiFreqBClrLmt
|
||
Set the input port frequency clear threshold for clock B.
|
||
setMiFreqBTau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
|
||
setMiLOSErrCnt
|
||
Set the input port error count threshold for LOS signal faults.
|
||
setMiLOSClrCnt
|
||
Set the input port clear count threshold for LOS signal faults.
|
||
setMiAISErrCnt
|
||
Set the input port error count threshold for AIS signal faults.
|
||
setMiAISClrCnt
|
||
Set the input port clear count threshold for AIS signal faults.
|
||
setMiOOFErrCnt
|
||
Set the input port error count threshold for OOF signal faults.
|
||
setMiOOFClrCnt
|
||
Set the input port clear count threshold for OOF signal faults.
|
||
setMiBPVErrCnt
|
||
Set the input port error count threshold for BPV signal faults.
|
||
setMiBPVClrCnt
|
||
Set the input port clear count threshold for BPV signal faults.
|
||
setMiCRCErrCnt
|
||
Set the input port error count threshold for CRC signal faults.
|
||
setMiCRCClrCnt
|
||
Set the input port clear count threshold for CRC signal faults.
|
||
"
|
||
INDEX { setMiChassis, setMiSlot, setMiPort }
|
||
::= { setAlmThDs1E1InpTable 1 }
|
||
|
||
|
||
SetMiEntry ::=
|
||
SEQUENCE {
|
||
setMiChassis
|
||
INTEGER,
|
||
setMiSlot
|
||
INTEGER,
|
||
setMiPort
|
||
INTEGER,
|
||
|
||
-- MTIE Threshold Setting
|
||
setMiMtieStd
|
||
INTEGER,
|
||
|
||
setMiMtie10EL1
|
||
INTEGER,
|
||
setMiMtie10EL2
|
||
INTEGER,
|
||
setMiMtie10CL1
|
||
INTEGER,
|
||
setMiMtie10CL2
|
||
INTEGER,
|
||
|
||
setMiMtie100EL1
|
||
INTEGER,
|
||
setMiMtie100EL2
|
||
INTEGER,
|
||
setMiMtie100CL1
|
||
INTEGER,
|
||
setMiMtie100CL2
|
||
INTEGER,
|
||
|
||
setMiMtie1000EL1
|
||
INTEGER,
|
||
setMiMtie1000EL2
|
||
INTEGER,
|
||
setMiMtie1000CL1
|
||
INTEGER,
|
||
setMiMtie1000CL2
|
||
INTEGER,
|
||
|
||
setMiMtie10000EL1
|
||
INTEGER,
|
||
setMiMtie10000EL2
|
||
INTEGER,
|
||
setMiMtie10000CL1
|
||
INTEGER,
|
||
setMiMtie10000CL2
|
||
INTEGER,
|
||
|
||
setMiMtie100000EL1
|
||
INTEGER,
|
||
setMiMtie100000EL2
|
||
INTEGER,
|
||
setMiMtie100000CL1
|
||
INTEGER,
|
||
setMiMtie100000CL2
|
||
INTEGER,
|
||
|
||
-- FREQ Threshold Setting
|
||
setMiFreqAErrLmt
|
||
INTEGER,
|
||
setMiFreqAClrLmt
|
||
INTEGER,
|
||
setMiFreqATau
|
||
INTEGER,
|
||
|
||
setMiFreqBErrLmt
|
||
INTEGER,
|
||
setMiFreqBClrLmt
|
||
INTEGER,
|
||
setMiFreqBTau
|
||
INTEGER,
|
||
|
||
-- SIGNAL Threshold Setting
|
||
setMiLOSErrCnt
|
||
INTEGER,
|
||
setMiLOSClrCnt
|
||
INTEGER,
|
||
setMiAISErrCnt
|
||
INTEGER,
|
||
setMiAISClrCnt
|
||
INTEGER,
|
||
setMiOOFErrCnt
|
||
INTEGER,
|
||
setMiOOFClrCnt
|
||
INTEGER,
|
||
setMiBPVErrCnt
|
||
INTEGER,
|
||
setMiBPVClrCnt
|
||
INTEGER,
|
||
setMiCRCErrCnt
|
||
INTEGER,
|
||
setMiCRCClrCnt
|
||
INTEGER
|
||
}
|
||
|
||
|
||
setMiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setMiEntry 1 }
|
||
|
||
setMiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setMiEntry 2 }
|
||
|
||
|
||
setMiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setMiEntry 3 }
|
||
|
||
setMiMtieStd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
prs(1),
|
||
ds1(2),
|
||
g811(3),
|
||
g823(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port setting of the MTIE limits to predefined values.
|
||
prs(1), -- ANSI T1.101 PRS MTIE MASK
|
||
ds1(2), -- ANSI T1.101 DS1 MTIE MASK
|
||
g811(3), -- G.811 (PRC) MTIE MASK
|
||
g823(4) -- G.823 (SSU) MTIE MASK
|
||
|
||
This field is only meaningful for a write operation.
|
||
"
|
||
::= { setMiEntry 4 }
|
||
|
||
setMiMtie10EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 5 }
|
||
|
||
setMiMtie10EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 6 }
|
||
|
||
setMiMtie10CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 7 }
|
||
|
||
setMiMtie10CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 8 }
|
||
|
||
|
||
|
||
setMiMtie100EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 9 }
|
||
|
||
setMiMtie100EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 10 }
|
||
|
||
setMiMtie100CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 11 }
|
||
|
||
setMiMtie100CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 12 }
|
||
|
||
|
||
setMiMtie1000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 13 }
|
||
|
||
setMiMtie1000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 14 }
|
||
|
||
setMiMtie1000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 15 }
|
||
|
||
setMiMtie1000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 16 }
|
||
|
||
|
||
|
||
setMiMtie10000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 17 }
|
||
|
||
setMiMtie10000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 18 }
|
||
|
||
|
||
setMiMtie10000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 19 }
|
||
|
||
setMiMtie10000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 20 }
|
||
|
||
|
||
setMiMtie100000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 21 }
|
||
|
||
setMiMtie100000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 22 }
|
||
|
||
|
||
setMiMtie100000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMiEntry 23 }
|
||
|
||
setMiMtie100000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMiEntry 24 }
|
||
|
||
|
||
|
||
setMiFreqAErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency error threshold for clock A.
|
||
"
|
||
::= { setMiEntry 25 }
|
||
|
||
setMiFreqAClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency clear threshold for clock A.
|
||
"
|
||
::= { setMiEntry 26 }
|
||
|
||
setMiFreqATau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock A.
|
||
"
|
||
::= { setMiEntry 27 }
|
||
|
||
|
||
setMiFreqBErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency error threshold for clock B.
|
||
"
|
||
::= { setMiEntry 28 }
|
||
|
||
setMiFreqBClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port frequency clear threshold for clock B.
|
||
"
|
||
::= { setMiEntry 29 }
|
||
|
||
setMiFreqBTau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock B.
|
||
"
|
||
::= { setMiEntry 30 }
|
||
|
||
setMiLOSErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for LOS signal faults.
|
||
"
|
||
::= { setMiEntry 31 }
|
||
|
||
setMiLOSClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for LOS signal faults.
|
||
"
|
||
::= { setMiEntry 32 }
|
||
|
||
setMiAISErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for AIS signal faults.
|
||
"
|
||
::= { setMiEntry 33 }
|
||
|
||
setMiAISClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for AIS signal faults.
|
||
"
|
||
::= { setMiEntry 34 }
|
||
|
||
setMiOOFErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for OOF signal faults.
|
||
"
|
||
::= { setMiEntry 35 }
|
||
|
||
setMiOOFClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for OOF signal faults.
|
||
"
|
||
::= { setMiEntry 36 }
|
||
|
||
setMiBPVErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for BPV signal faults.
|
||
"
|
||
::= { setMiEntry 37 }
|
||
|
||
setMiBPVClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for BPV signal faults.
|
||
"
|
||
::= { setMiEntry 38 }
|
||
|
||
setMiCRCErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count hreshold for CRC signal faults.
|
||
"
|
||
::= { setMiEntry 39 }
|
||
|
||
setMiCRCClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for CRC signal faults.
|
||
"
|
||
::= { setMiEntry 40 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 COMPOSITE CLOCK INPUT MODULE SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
|
||
-- ******************************************
|
||
-- COMPOSITE CLOCK INPUT MODULE SETTING
|
||
-- ******************************************
|
||
|
||
setCcInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetCiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The list of CC Input attribute setup information.
|
||
"
|
||
::= { setupCcInp 2 }
|
||
|
||
|
||
setCiEntry OBJECT-TYPE
|
||
SYNTAX SetCiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input status and settings attributes.
|
||
"
|
||
INDEX { setCiChassis, setCiSlot, setCiPort }
|
||
::= { setCcInpTable 1 }
|
||
|
||
SetCiEntry ::=
|
||
SEQUENCE {
|
||
setCiChassis
|
||
INTEGER,
|
||
setCiSlot
|
||
INTEGER,
|
||
setCiPort
|
||
INTEGER,
|
||
setCiEnable
|
||
EnaValue,
|
||
setCiProvPql
|
||
INTEGER,
|
||
setCiPriority
|
||
INTEGER,
|
||
setCiZeroPhase
|
||
INTEGER
|
||
}
|
||
|
||
setCiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The input module can only reside in chassis 1 (main chassis).
|
||
"
|
||
::= { setCiEntry 1 }
|
||
|
||
setCiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCiEntry 2 }
|
||
|
||
|
||
setCiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCiEntry 3 }
|
||
|
||
|
||
setCiEnable OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port to enabled or disabled.
|
||
"
|
||
::= { setCiEntry 4 }
|
||
|
||
setCiProvPql OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port provisioned Priority Quality Level (PQL).
|
||
|
||
Note: Valid values are 1 - 9.
|
||
"
|
||
::= { setCiEntry 7 }
|
||
|
||
|
||
setCiPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port priority level.
|
||
'0' = monitoring,
|
||
'1' = highest priority,
|
||
'10' = lowest priority.
|
||
"
|
||
::= { setCiEntry 8 }
|
||
|
||
|
||
setCiZeroPhase OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
zeroPhA(1),
|
||
zeroPhB(2),
|
||
zeroPhAB(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the phase error to zero for this input port.
|
||
ZEROPHA - set phase A error to zero,
|
||
ZEROPHB - set phase B error to zero,
|
||
ZEROPHAB - set phase A and B to zero.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
"
|
||
::= { setCiEntry 9 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- CCINP ALARM THRESHOLD SETTING
|
||
-- ******************************************
|
||
|
||
setAlmThCcInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetCimEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of CC input alarm attributes and settings information.
|
||
"
|
||
::= { setupCcInp 4 }
|
||
|
||
|
||
setCimEntry OBJECT-TYPE
|
||
SYNTAX SetCimEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input alarm attributes and settings.
|
||
setMiChassis
|
||
Identifies which chassis is being addressed.
|
||
setMiSlot
|
||
Identifies which slot position is being addressed.
|
||
setMiPort
|
||
Identifies which port position is being addressed.
|
||
setCimLOSErrCnt
|
||
Set the input port error count threshold for LOS signal faults.
|
||
setCimLOSClrCnt
|
||
Set the input port clear count threshold for LOS signal faults.
|
||
setCimBPVErrCnt
|
||
Set the input port error count threshold for BPV signal faults.
|
||
setCimBPVClrCnt
|
||
Set the input port clear count threshold for BPV signal faults.
|
||
"
|
||
INDEX { setCimChassis, setCimSlot, setCimPort }
|
||
::= { setAlmThCcInpTable 1 }
|
||
|
||
|
||
SetCimEntry ::=
|
||
SEQUENCE {
|
||
setCimChassis
|
||
INTEGER,
|
||
setCimSlot
|
||
INTEGER,
|
||
setCimPort
|
||
INTEGER,
|
||
|
||
-- SIGNAL Threshold Setting
|
||
setCimLOSErrCnt
|
||
INTEGER,
|
||
setCimLOSClrCnt
|
||
INTEGER,
|
||
setCimBPVErrCnt
|
||
INTEGER,
|
||
setCimBPVClrCnt
|
||
INTEGER
|
||
}
|
||
|
||
|
||
setCimChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setCimEntry 1 }
|
||
|
||
setCimSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCimEntry 2 }
|
||
|
||
|
||
setCimPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCimEntry 3 }
|
||
|
||
setCimLOSErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for LOS signal faults.
|
||
"
|
||
::= { setCimEntry 4 }
|
||
|
||
setCimLOSClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for LOS signal faults.
|
||
"
|
||
::= { setCimEntry 5 }
|
||
|
||
setCimBPVErrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port error count threshold for BPV signal faults.
|
||
"
|
||
::= { setCimEntry 10 }
|
||
|
||
setCimBPVClrCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port clear count threshold for BPV signal faults.
|
||
"
|
||
::= { setCimEntry 11 }
|
||
|
||
|
||
-- ******************************************
|
||
-- JAPANESE SINE INPUT MODULE SETTING
|
||
-- ******************************************
|
||
|
||
setSineInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetSineiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The list of Sine Input attribute setup information.
|
||
"
|
||
::= { setupSineInp 2 }
|
||
|
||
|
||
setSineiEntry OBJECT-TYPE
|
||
SYNTAX SetSineiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input status and settings attributes.
|
||
"
|
||
INDEX { setSineiChassis, setSineiSlot, setSineiPort }
|
||
::= { setSineInpTable 1 }
|
||
|
||
SetSineiEntry ::=
|
||
SEQUENCE {
|
||
setSineiChassis
|
||
INTEGER,
|
||
setSineiSlot
|
||
INTEGER,
|
||
setSineiPort
|
||
INTEGER,
|
||
setSineiEnable
|
||
EnaValue,
|
||
setSineiFrequency
|
||
INTEGER,
|
||
setSineiProvPql
|
||
INTEGER,
|
||
setSineiPriority
|
||
INTEGER,
|
||
setSineiCSFlt
|
||
INTEGER,
|
||
|
||
setSineiZeroPhase
|
||
INTEGER
|
||
}
|
||
|
||
setSineiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The input module can only reside in chassis 1 (main chassis).
|
||
"
|
||
::= { setSineiEntry 1 }
|
||
|
||
setSineiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setSineiEntry 2 }
|
||
|
||
|
||
setSineiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setSineiEntry 3 }
|
||
|
||
|
||
setSineiEnable OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port to enabled or disabled.
|
||
"
|
||
::= { setSineiEntry 4 }
|
||
|
||
|
||
setSineiFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER (1544|6312)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set input signal frequency.
|
||
The frequency can be set: 1.544MHZ/ 6.312MHz.
|
||
"
|
||
::= { setSineiEntry 5 }
|
||
|
||
setSineiProvPql OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port provisioned Priority Quality Level (PQL).
|
||
|
||
Note: Valid values are 1 - 9.
|
||
"
|
||
::= { setSineiEntry 6 }
|
||
|
||
|
||
setSineiPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port priority level.
|
||
'0' = monitoring,
|
||
'1' = highest priority,
|
||
'10' = lowest priority.
|
||
"
|
||
::= { setSineiEntry 7 }
|
||
|
||
|
||
setSineiCSFlt OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
off(1),
|
||
low(2),
|
||
high(3),
|
||
na(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set input Port 1 for external Cesium (CS) fault alarm logic level.
|
||
off(1), -- function is disabled
|
||
low(2), -- function is enabled, will trigger on low (0V) level
|
||
high(3), -- function is enabled, will trigger on high (+5v) level
|
||
na(4) -- not applicable
|
||
|
||
Note: only available for port one.
|
||
"
|
||
::= { setSineiEntry 8 }
|
||
|
||
setSineiZeroPhase OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
zeroPhA(1),
|
||
zeroPhB(2),
|
||
zeroPhAB(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the phase error to zero for this input port.
|
||
ZEROPHA - set phase A error to zero,
|
||
ZEROPHB - set phase B error to zero,
|
||
ZEROPHAB - set phase A and B to zero.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
"
|
||
::= { setSineiEntry 9 }
|
||
|
||
|
||
|
||
-- *******************************************
|
||
-- JAPANESE SINE INPUT ALARM THRESHOLD SETTING
|
||
-- *******************************************
|
||
|
||
setAlmThSineInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetMsiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Sine input alarm attributes and settings information.
|
||
"
|
||
::= { setupSineInp 4 }
|
||
|
||
setMsiEntry OBJECT-TYPE
|
||
SYNTAX SetMsiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input alarm attributes and settings.
|
||
setMsiChassis
|
||
Identifies which chassis is being addressed.
|
||
setMsiSlot
|
||
Identifies which slot position is being addressed.
|
||
setMsiPort
|
||
Identifies which port position is being addressed.
|
||
setMsiMtieStd
|
||
Set the input port setting of the MTIE limits to predefined values.
|
||
setMsiMtie10EL1
|
||
Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
setMsiMtie10EL2
|
||
Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
setMsiMtie10CL1
|
||
Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
setMsiMtie10CL2
|
||
Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
setMsiMtie100EL1
|
||
Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
setMsiMtie100EL2
|
||
Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
setMsiMtie100CL1
|
||
Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
setMsiMtie100CL2
|
||
Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
setMsiMtie1000EL1
|
||
Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
setMsiMtie1000EL2
|
||
Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
setMsiMtie1000CL1
|
||
Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
setMsiMtie1000CL2
|
||
Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
setMsiMtie10000EL1
|
||
Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
setMsiMtie10000EL2
|
||
Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
setMsiMtie10000CL1
|
||
Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
setMsiMtie10000CL2
|
||
Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
setMsiMtie100000EL1
|
||
Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
setMsiMtie100000EL2
|
||
Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
setMsiMtie100000CL1
|
||
Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
setMsiMtie100000CL2
|
||
Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
setMsiFreqAErrLmt
|
||
Set the input port frequency error threshold for clock A.
|
||
setMsiFreqAClrLmt
|
||
Set the input port frequency clear threshold for clock A.
|
||
setMsiFreqATau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A.
|
||
setMsiFreqBErrLmt
|
||
Set the input port frequency error threshold for clock B.
|
||
setMsiFreqBClrLmt
|
||
Set the input port frequency clear threshold for clock B.
|
||
setMsiFreqBTau
|
||
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
|
||
"
|
||
INDEX { setMsiChassis, setMsiSlot, setMsiPort }
|
||
::= { setAlmThSineInpTable 1 }
|
||
|
||
SetMsiEntry ::=
|
||
SEQUENCE {
|
||
setMsiChassis
|
||
INTEGER,
|
||
setMsiSlot
|
||
INTEGER,
|
||
setMsiPort
|
||
INTEGER,
|
||
|
||
-- MTIE Threshold Setting
|
||
setMsiMtieStd
|
||
INTEGER,
|
||
|
||
setMsiMtie10EL1
|
||
INTEGER,
|
||
setMsiMtie10EL2
|
||
INTEGER,
|
||
setMsiMtie10CL1
|
||
INTEGER,
|
||
setMsiMtie10CL2
|
||
INTEGER,
|
||
|
||
setMsiMtie100EL1
|
||
INTEGER,
|
||
setMsiMtie100EL2
|
||
INTEGER,
|
||
setMsiMtie100CL1
|
||
INTEGER,
|
||
setMsiMtie100CL2
|
||
INTEGER,
|
||
|
||
setMsiMtie1000EL1
|
||
INTEGER,
|
||
setMsiMtie1000EL2
|
||
INTEGER,
|
||
setMsiMtie1000CL1
|
||
INTEGER,
|
||
setMsiMtie1000CL2
|
||
INTEGER,
|
||
|
||
setMsiMtie10000EL1
|
||
INTEGER,
|
||
setMsiMtie10000EL2
|
||
INTEGER,
|
||
setMsiMtie10000CL1
|
||
INTEGER,
|
||
setMsiMtie10000CL2
|
||
INTEGER,
|
||
|
||
setMsiMtie100000EL1
|
||
INTEGER,
|
||
setMsiMtie100000EL2
|
||
INTEGER,
|
||
setMsiMtie100000CL1
|
||
INTEGER,
|
||
setMsiMtie100000CL2
|
||
INTEGER,
|
||
|
||
-- FREQ Threshold Setting
|
||
setMsiFreqAErrLmt
|
||
INTEGER,
|
||
setMsiFreqAClrLmt
|
||
INTEGER,
|
||
setMsiFreqATau
|
||
INTEGER,
|
||
|
||
setMsiFreqBErrLmt
|
||
INTEGER,
|
||
setMsiFreqBClrLmt
|
||
INTEGER,
|
||
setMsiFreqBTau
|
||
INTEGER
|
||
}
|
||
|
||
setMsiChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
|
||
Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
|
||
"
|
||
::= { setMsiEntry 1 }
|
||
|
||
setMsiSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setMsiEntry 2 }
|
||
|
||
|
||
setMsiPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot number, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setMsiEntry 3 }
|
||
|
||
setMsiMtieStd OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
prs(1),
|
||
ds1(2),
|
||
g811(3),
|
||
g823(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port setting of the MTIE limits to predefined values.
|
||
prs(1), -- ANSI T1.101 PRS MTIE MASK
|
||
ds1(2), -- ANSI T1.101 DS1 MTIE MASK
|
||
g811(3), -- G.811 (PRC) MTIE MASK
|
||
g823(4) -- G.823 (SSU) MTIE MASK
|
||
|
||
This field is only meaningful for a write operation.
|
||
"
|
||
::= { setMsiEntry 4 }
|
||
|
||
setMsiMtie10EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 5 }
|
||
|
||
setMsiMtie10EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 6 }
|
||
|
||
setMsiMtie10CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 7 }
|
||
|
||
setMsiMtie10CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 8 }
|
||
|
||
|
||
|
||
setMsiMtie100EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 9 }
|
||
|
||
setMsiMtie100EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 10 }
|
||
|
||
setMsiMtie100CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 11 }
|
||
|
||
setMsiMtie100CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 12 }
|
||
|
||
|
||
setMsiMtie1000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 13 }
|
||
|
||
setMsiMtie1000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 14 }
|
||
|
||
setMsiMtie1000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 15 }
|
||
|
||
setMsiMtie1000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 16 }
|
||
|
||
|
||
|
||
setMsiMtie10000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 17 }
|
||
|
||
setMsiMtie10000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 18 }
|
||
|
||
|
||
setMsiMtie10000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 19 }
|
||
|
||
setMsiMtie10000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 20 }
|
||
|
||
|
||
setMsiMtie100000EL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 21 }
|
||
|
||
setMsiMtie100000EL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds error threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 22 }
|
||
|
||
setMsiMtie100000CL1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
|
||
"
|
||
::= { setMsiEntry 23 }
|
||
|
||
setMsiMtie100000CL2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
|
||
"
|
||
::= { setMsiEntry 24 }
|
||
|
||
|
||
|
||
setMsiFreqAErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets input port frequency error threshold for clock A.
|
||
"
|
||
::= { setMsiEntry 25 }
|
||
|
||
setMsiFreqAClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets input port frequency clear threshold for clock A.
|
||
"
|
||
::= { setMsiEntry 26 }
|
||
|
||
setMsiFreqATau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock A.
|
||
"
|
||
::= { setMsiEntry 27 }
|
||
|
||
|
||
setMsiFreqBErrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets input port frequency error threshold for clock B.
|
||
"
|
||
::= { setMsiEntry 28 }
|
||
|
||
setMsiFreqBClrLmt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets input port frequency clear threshold for clock B.
|
||
"
|
||
::= { setMsiEntry 29 }
|
||
|
||
setMsiFreqBTau OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock B.
|
||
"
|
||
::= { setMsiEntry 30 }
|
||
|
||
-- ******************************************
|
||
-- JAPANESE CC INPUT MODULE SETTING
|
||
-- ******************************************
|
||
|
||
setJccInpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetJcciEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The list of CC Input attribute setup information.
|
||
"
|
||
::= { setupJccInp 2 }
|
||
|
||
|
||
setJcciEntry OBJECT-TYPE
|
||
SYNTAX SetJcciEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Input status and settings attributes.
|
||
"
|
||
INDEX { setJcciChassis, setJcciSlot, setJcciPort }
|
||
::= { setJccInpTable 1 }
|
||
|
||
SetJcciEntry ::=
|
||
SEQUENCE {
|
||
setJcciChassis
|
||
INTEGER,
|
||
setJcciSlot
|
||
INTEGER,
|
||
setJcciPort
|
||
INTEGER,
|
||
setJcciEnable
|
||
EnaValue,
|
||
setJcciProvPql
|
||
INTEGER,
|
||
setJcciPriority
|
||
INTEGER,
|
||
setJcci400Hz
|
||
OnValue,
|
||
|
||
setJcciZeroPhase
|
||
INTEGER
|
||
}
|
||
|
||
setJcciChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
|
||
Note: The input module can only reside in chassis 1 (main chassis).
|
||
"
|
||
::= { setJcciEntry 1 }
|
||
|
||
setJcciSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setJcciEntry 2 }
|
||
|
||
|
||
setJcciPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setJcciEntry 3 }
|
||
|
||
|
||
setJcciEnable OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port to enabled or disabled.
|
||
"
|
||
::= { setJcciEntry 4 }
|
||
|
||
|
||
setJcciProvPql OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port provisioned Priority Quality Level (PQL).
|
||
|
||
Note: Valid values are 1 - 9.
|
||
"
|
||
::= { setJcciEntry 5 }
|
||
|
||
|
||
setJcciPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port priority level.
|
||
'0' = monitoring,
|
||
'1' = highest priority,
|
||
'10' = lowest priority.
|
||
"
|
||
::= { setJcciEntry 6 }
|
||
|
||
setJcci400Hz OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the input port 400Hz signal attribute.
|
||
"
|
||
::= { setJcciEntry 7 }
|
||
|
||
setJcciZeroPhase OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
zeroPhA(1),
|
||
zeroPhB(2),
|
||
zeroPhAB(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the phase error to zero for this input port.
|
||
ZEROPHA - set phase A error to zero,
|
||
ZEROPHB - set phase B error to zero,
|
||
ZEROPHAB - set phase A and B to zero.
|
||
|
||
Note: This field only is meaningful during the write operation.
|
||
"
|
||
::= { setJcciEntry 8 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 DS1/E1 OUT SETUP GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- DS1 OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setDsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetDsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1 output module status and settings.
|
||
"
|
||
::= { setupDs1Out 2 }
|
||
|
||
|
||
setDsEntry OBJECT-TYPE
|
||
SYNTAX SetDsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set DS1 output attributes.
|
||
"
|
||
INDEX { setDsChassis, setDsSlot}
|
||
::= { setDsTable 1 }
|
||
|
||
SetDsEntry ::=
|
||
SEQUENCE {
|
||
setDsChassis
|
||
INTEGER,
|
||
setDsSlot
|
||
INTEGER,
|
||
setDsFrame
|
||
INTEGER,
|
||
setDsBypass
|
||
OnValue,
|
||
setDsZs
|
||
OnValue,
|
||
setDsEnable
|
||
OCTET STRING,
|
||
setDsLength
|
||
OCTET STRING
|
||
}
|
||
|
||
setDsChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setDsEntry 1 }
|
||
|
||
setDsSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setDsEntry 2 }
|
||
|
||
|
||
setDsFrame OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
esf(1),
|
||
d4(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output signal framing mode.
|
||
The T1 framing mode is ESF or D4.
|
||
"
|
||
::= { setDsEntry 3 }
|
||
|
||
setDsBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setDsEntry 4 }
|
||
|
||
setDsZs OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Zero Suppression to enable or disable.
|
||
"
|
||
::= { setDsEntry 5 }
|
||
|
||
|
||
setDsEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setDsEntry 6 }
|
||
|
||
setDsLength OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the cable length compensation for the output port.
|
||
|
||
Cable length definitions:
|
||
1 = 133 ft
|
||
2 = 266 ft
|
||
3 = 399 ft
|
||
4 = 533 ft
|
||
5 = 655 ft
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setDsEntry 7 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- E1 OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setE1Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetE1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1 output module status and settings.
|
||
"
|
||
::= { setupE1Out 2 }
|
||
|
||
|
||
setE1Entry OBJECT-TYPE
|
||
SYNTAX SetE1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set DS1 output attributes.
|
||
"
|
||
INDEX { setE1Chassis, setE1Slot}
|
||
::= { setE1Table 1 }
|
||
|
||
SetE1Entry ::=
|
||
SEQUENCE {
|
||
setE1Chassis
|
||
INTEGER,
|
||
setE1Slot
|
||
INTEGER,
|
||
setE1Frame
|
||
INTEGER,
|
||
setE1Bypass
|
||
OnValue,
|
||
setE1Zs
|
||
OnValue,
|
||
setE1Crc
|
||
OnValue,
|
||
setE1SsmBit
|
||
INTEGER,
|
||
setE1Enable
|
||
OCTET STRING
|
||
}
|
||
|
||
setE1Chassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setE1Entry 1 }
|
||
|
||
setE1Slot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setE1Entry 2 }
|
||
|
||
|
||
setE1Frame OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ccs(1),
|
||
cas(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output signal framing mode.
|
||
1=ccs
|
||
2=cas
|
||
"
|
||
::= { setE1Entry 3 }
|
||
|
||
setE1Bypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setE1Entry 4 }
|
||
|
||
setE1Zs OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Zero Suppression to enable or disable.
|
||
"
|
||
::= { setE1Entry 5 }
|
||
|
||
setE1Crc OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the CRC error checking to enable or disable.
|
||
"
|
||
::= { setE1Entry 6 }
|
||
|
||
|
||
setE1SsmBit OBJECT-TYPE
|
||
SYNTAX INTEGER (4..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set output module E1 SSM bit position.
|
||
bit=4 - 8
|
||
|
||
Note: This field is only valid for E1 output module.
|
||
"
|
||
::= { setE1Entry 7 }
|
||
|
||
setE1Enable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setE1Entry 8 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- 2048kHz OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setCoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetCoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of 2048kHz output module status and settings.
|
||
"
|
||
::= { setup2048Out 2 }
|
||
|
||
setCoEntry OBJECT-TYPE
|
||
SYNTAX SetCoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set 2048kHz output attributes.
|
||
"
|
||
INDEX { setCoChassis, setCoSlot}
|
||
::= { setCoTable 1 }
|
||
|
||
SetCoEntry ::=
|
||
SEQUENCE {
|
||
setCoChassis
|
||
INTEGER,
|
||
setCoSlot
|
||
INTEGER,
|
||
setCoBypass
|
||
OnValue,
|
||
setCoFltMode
|
||
INTEGER,
|
||
setCoEnable
|
||
OCTET STRING,
|
||
setCoSquelch
|
||
OCTET STRING
|
||
}
|
||
|
||
setCoChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCoEntry 1 }
|
||
|
||
setCoSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setCoEntry 2 }
|
||
|
||
setCoBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setCoEntry 3 }
|
||
|
||
setCoFltMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
off(1),
|
||
on(2),
|
||
auto(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the signal fault mode for low level output signals
|
||
off(1), -- will turn off the output and requires user issued command to turn it back on
|
||
on(2), -- will not turn off when fault detected
|
||
auto(3) -- will turn off the output and automatically turn back on when fault clears
|
||
"
|
||
::= { setCoEntry 4 }
|
||
|
||
setCoEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setCoEntry 5 }
|
||
|
||
setCoSquelch OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PQL threshold to turn port off.
|
||
If the system PQL is below the PWL threshold the port is turned off (i.e. squelched).
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
The PQL value of each byte defined as follows:
|
||
0 = disabled
|
||
1-16 = Provision PQL value
|
||
"
|
||
::= { setCoEntry 6 }
|
||
|
||
-- ******************************************
|
||
-- COMPOSITE CLOCK OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setCcTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetCcEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Composite Clock (CC) output module status and settings.
|
||
"
|
||
::= { setupCCOut 2 }
|
||
|
||
setCcEntry OBJECT-TYPE
|
||
SYNTAX SetCcEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set CC output attributes.
|
||
"
|
||
INDEX { setCcChassis, setCcSlot}
|
||
::= { setCcTable 1 }
|
||
|
||
SetCcEntry ::=
|
||
SEQUENCE {
|
||
setCcChassis
|
||
INTEGER,
|
||
setCcSlot
|
||
INTEGER,
|
||
setCcBypass
|
||
OnValue,
|
||
setCcEnable
|
||
OCTET STRING,
|
||
setCcDuty
|
||
OCTET STRING,
|
||
setCcComp
|
||
OCTET STRING
|
||
}
|
||
|
||
setCcChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each CC Output entry.
|
||
"
|
||
::= { setCcEntry 1 }
|
||
|
||
setCcSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each CC Output entry.
|
||
"
|
||
::= { setCcEntry 2 }
|
||
|
||
setCcBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setCcEntry 3 }
|
||
|
||
setCcEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setCcEntry 4 }
|
||
|
||
|
||
setCcDuty OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output duty cycle for the output ports.
|
||
1 = 63/37 duty cycle.
|
||
2 = 50/50 duty cycle.
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setCcEntry 5 }
|
||
|
||
|
||
setCcComp OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output phase (cable) compensation for the output ports.
|
||
|
||
The equivalent cable length:
|
||
1 = 2200 ft,
|
||
2 = 1925 ft,
|
||
3 = 1650 ft,
|
||
4 = 1375 ft,
|
||
5 = 1100 ft,
|
||
6 = 825 ft,
|
||
7 = 550 ft,
|
||
8 = 275 ft.
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setCcEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- RS422 OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
set422oTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Set422oEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of 2048kHz output module status and settings.
|
||
"
|
||
::= { setup422Out 2 }
|
||
|
||
set422oEntry OBJECT-TYPE
|
||
SYNTAX Set422oEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set 422 output attributes.
|
||
"
|
||
INDEX { set422oChassis, set422oSlot}
|
||
::= { set422oTable 1 }
|
||
|
||
Set422oEntry ::=
|
||
SEQUENCE {
|
||
set422oChassis
|
||
INTEGER,
|
||
set422oSlot
|
||
INTEGER,
|
||
set422oBypass
|
||
OnValue,
|
||
set422oFltMode
|
||
INTEGER,
|
||
set422oEnable
|
||
OCTET STRING,
|
||
set422oFrequency
|
||
OCTET STRING
|
||
}
|
||
|
||
set422oChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { set422oEntry 1 }
|
||
|
||
set422oSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { set422oEntry 2 }
|
||
|
||
set422oBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { set422oEntry 3 }
|
||
|
||
set422oFltMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
off(1),
|
||
on(2),
|
||
auto(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the signal fault mode for low level output signals
|
||
off(1), -- will turn off the output and requires user issued command to turn it back on
|
||
on(2), -- will not turn off when fault detected
|
||
auto(3) -- will turn off the output and automatically turn back on when fault clears
|
||
"
|
||
::= { set422oEntry 4 }
|
||
|
||
set422oEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { set422oEntry 5 }
|
||
|
||
set422oFrequency OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set frequency for each port on an RS422 output module.
|
||
|
||
word 1 = port 1, word 10 = port 10.
|
||
The frequency value of each port defined as follows:
|
||
0 = 4kHz, 1-512 = 8kHz to 4096kHz with 8kHz per step.
|
||
|
||
Note: each port use 2-bytes to set frequency.
|
||
User can only set frequency on port 1 thru port 10.
|
||
The port 1 and 11, port 2 and 12,.., port 10 and 20 have the same frequency setting.
|
||
For example, when you set port1, you are set the same frequency for port 11.
|
||
"
|
||
::= { set422oEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- Selectable E1/2048 OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setE12048oTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetE12048oEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of E1/2048 output module status and settings.
|
||
"
|
||
::= { setupE12048Out 2 }
|
||
|
||
setE12048oEntry OBJECT-TYPE
|
||
SYNTAX SetE12048oEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1/2048 output attributes.
|
||
"
|
||
INDEX { setE12048oChassis, setE12048oSlot}
|
||
::= { setE12048oTable 1 }
|
||
|
||
SetE12048oEntry ::=
|
||
SEQUENCE {
|
||
setE12048oChassis
|
||
INTEGER,
|
||
setE12048oSlot
|
||
INTEGER,
|
||
setE12048oBypass
|
||
OnValue,
|
||
setE12048oZs
|
||
OnValue,
|
||
setE12048oSignal
|
||
OCTET STRING,
|
||
setE12048oEnable
|
||
OCTET STRING,
|
||
setE12048oSquelch
|
||
OCTET STRING,
|
||
setE12048oFrame
|
||
INTEGER,
|
||
setE12048oCrc
|
||
OnValue,
|
||
setE12048oSsm
|
||
OnValue,
|
||
setE12048oSsmBit
|
||
INTEGER
|
||
}
|
||
|
||
setE12048oChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setE12048oEntry 1 }
|
||
|
||
setE12048oSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setE12048oEntry 2 }
|
||
|
||
setE12048oBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setE12048oEntry 3 }
|
||
|
||
setE12048oZs OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Zero Suppression to enable or disable.
|
||
"
|
||
::= { setE12048oEntry 4 }
|
||
|
||
setE12048oSignal OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to E1 or 2048kHz.
|
||
1 = E1
|
||
2 = 2048 kHz
|
||
|
||
Note: byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setE12048oEntry 5 }
|
||
|
||
setE12048oEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setE12048oEntry 6 }
|
||
|
||
setE12048oSquelch OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PQL squelch threshold for each port.
|
||
If a PQL threshold is below the system PQL, this port is turned off (i.e. squelched).
|
||
0 = disabled
|
||
1-16 = Provision PQL value
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setE12048oEntry 7 }
|
||
|
||
setE12048oFrame OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ccs(1),
|
||
cas(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 output signal framer mode.
|
||
1 = CCS
|
||
2 = CAS
|
||
"
|
||
::= { setE12048oEntry 8 }
|
||
|
||
setE12048oCrc OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 output CRC error checking to on or off.
|
||
"
|
||
::= { setE12048oEntry 9 }
|
||
|
||
setE12048oSsm OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 output SSM generation to on or off.
|
||
"
|
||
::= { setE12048oEntry 10 }
|
||
|
||
setE12048oSsmBit OBJECT-TYPE
|
||
SYNTAX INTEGER (4..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 output SSM bit position.
|
||
bit position = 4 - 8
|
||
|
||
Note: This field is only valid for E1 output module.
|
||
"
|
||
::= { setE12048oEntry 11 }
|
||
|
||
-- ******************************************
|
||
-- DS1 LRM MODULE
|
||
-- ******************************************
|
||
|
||
setLrmPTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetLrmPEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of DS1 LRM ports status and settings.
|
||
"
|
||
::= { setupLrm 2 }
|
||
|
||
setLrmPEntry OBJECT-TYPE
|
||
SYNTAX SetLrmPEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set DS1 LRM attributes.
|
||
"
|
||
INDEX { setLrmPChassis, setLrmPSlot, setLrmPPort}
|
||
::= { setLrmPTable 1 }
|
||
|
||
SetLrmPEntry ::=
|
||
SEQUENCE {
|
||
setLrmPChassis
|
||
INTEGER,
|
||
setLrmPSlot
|
||
INTEGER,
|
||
setLrmPPort
|
||
INTEGER,
|
||
setLrmPEnable
|
||
OnValue,
|
||
setLrmPLbo
|
||
INTEGER,
|
||
setLrmPSlip
|
||
INTEGER,
|
||
setLrmPBpv
|
||
INTEGER,
|
||
setLrmPFlt
|
||
INTEGER,
|
||
setLrmPCid
|
||
DisplayString
|
||
}
|
||
|
||
setLrmPChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrmPEntry 1 }
|
||
|
||
setLrmPSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrmPEntry 2 }
|
||
|
||
setLrmPPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrmPEntry 3 }
|
||
|
||
setLrmPEnable OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the LRM ports to enabled or disabled.
|
||
"
|
||
::= { setLrmPEntry 4 }
|
||
|
||
setLrmPLbo OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
lbo133ft(1),
|
||
lbo266ft(2),
|
||
lbo399ft(3),
|
||
lbo533ft(4),
|
||
lbo655ft(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Line Build-Out for the LRM port.
|
||
1=lbo133ft
|
||
2=lbo266ft
|
||
3=lbo399ft
|
||
4=lbo533ft
|
||
5=lbo655ft
|
||
"
|
||
::= { setLrmPEntry 5 }
|
||
|
||
setLrmPSlip OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the slip error threshold in 24 hours period and the value zero shall clear the slip accumulated errors.
|
||
"
|
||
::= { setLrmPEntry 6 }
|
||
|
||
setLrmPBpv OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clr(1), -- clear the accumulated BPV errors
|
||
nop(2) -- no operation
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clear the accumulated BPV errors
|
||
clr(1), -- clear the accumulated BPV errors
|
||
nop(2) -- no operation
|
||
|
||
Note: This field only has meaning for a write operation.
|
||
"
|
||
::= { setLrmPEntry 7 }
|
||
|
||
setLrmPFlt OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
squelch(1),
|
||
ais(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Side 1 fault strategy
|
||
"
|
||
::= { setLrmPEntry 8 }
|
||
|
||
setLrmPCid OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..43))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the circuit id for LRM port
|
||
The circuit id is an 0-43 character string with all ascii printable characters.
|
||
"
|
||
::= { setLrmPEntry 9 }
|
||
|
||
|
||
-- ******************************************
|
||
-- E1 LRM MODULE
|
||
-- ******************************************
|
||
|
||
setLrme1PTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetLrme1PEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of E1 LRM ports status and settings.
|
||
"
|
||
::= { setupLrmE1 2 }
|
||
|
||
setLrme1PEntry OBJECT-TYPE
|
||
SYNTAX SetLrme1PEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 LRM attributes.
|
||
"
|
||
INDEX { setLrme1PChassis, setLrme1PSlot, setLrme1PPort}
|
||
::= { setLrme1PTable 1 }
|
||
|
||
SetLrme1PEntry ::=
|
||
SEQUENCE {
|
||
setLrme1PChassis
|
||
INTEGER,
|
||
setLrme1PSlot
|
||
INTEGER,
|
||
setLrme1PPort
|
||
INTEGER,
|
||
setLrme1PEnable
|
||
OnValue,
|
||
setLrme1PSlip
|
||
INTEGER,
|
||
setLrme1PBpv
|
||
INTEGER,
|
||
setLrme1PFlt
|
||
INTEGER,
|
||
setLrme1PCid
|
||
DisplayString
|
||
}
|
||
|
||
setLrme1PChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrme1PEntry 1 }
|
||
|
||
setLrme1PSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrme1PEntry 2 }
|
||
|
||
setLrme1PPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { setLrme1PEntry 3 }
|
||
|
||
setLrme1PEnable OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the LRM ports to enabled or disabled.
|
||
"
|
||
::= { setLrme1PEntry 4 }
|
||
|
||
setLrme1PSlip OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the slip error threshold in 24 hours period and the value zero shall clear the slip accumulated errors.
|
||
"
|
||
::= { setLrme1PEntry 5 }
|
||
|
||
setLrme1PBpv OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clr(1), -- clear the accumulated BPV errors
|
||
nop(2) -- no operation
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clear the accumulated BPV errors
|
||
clr(1), -- clear the accumulated BPV errors
|
||
nop(2) -- no operation
|
||
|
||
Note: This field only has meaning for a write operation.
|
||
"
|
||
::= { setLrme1PEntry 6 }
|
||
|
||
setLrme1PFlt OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
squelch(1),
|
||
ais(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Side 1 fault strategy
|
||
"
|
||
::= { setLrme1PEntry 7 }
|
||
|
||
setLrme1PCid OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..43))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the circuit id for LRM port
|
||
The circuit id is an 0-43 character string with all ascii printable characters.
|
||
"
|
||
::= { setLrme1PEntry 8 }
|
||
|
||
|
||
-- ******************************************
|
||
-- JAPANESE SINE OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setSineoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetSineoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of Sine output status and settings.
|
||
"
|
||
::= { setupSineOut 2 }
|
||
|
||
setSineoEntry OBJECT-TYPE
|
||
SYNTAX SetSineoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E1 LRM attributes.
|
||
"
|
||
INDEX { setSineoChassis, setSineoSlot}
|
||
::= { setSineoTable 1 }
|
||
|
||
SetSineoEntry ::=
|
||
SEQUENCE {
|
||
setSineoChassis
|
||
INTEGER,
|
||
setSineoSlot
|
||
INTEGER,
|
||
setSineoBypass
|
||
OnValue,
|
||
setSineoFrequency
|
||
INTEGER,
|
||
setSineoEnable
|
||
OCTET STRING,
|
||
setSineoSquelch
|
||
OCTET STRING
|
||
}
|
||
|
||
setSineoChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setSineoEntry 1 }
|
||
|
||
setSineoSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { setSineoEntry 2 }
|
||
|
||
setSineoBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setSineoEntry 3 }
|
||
|
||
setSineoFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER (1544|6312)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output frequency 1.544 or 6.312 MHz.
|
||
"
|
||
::= { setSineoEntry 4 }
|
||
|
||
setSineoEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setSineoEntry 5 }
|
||
|
||
setSineoSquelch OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PQL threshold to turn port off.
|
||
If the system PQL is below the PWL threshold the port is turned off (i.e. squelched).
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
The PQL value of each byte defined as follows:
|
||
0 = disabled
|
||
1-16 = Provision PQL value
|
||
"
|
||
::= { setSineoEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- 64+8+4 (JAPANESE) CC OUTPUT MODULE
|
||
-- ******************************************
|
||
|
||
setJccoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetJccoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of JCC output status and settings.
|
||
"
|
||
::= { setupJccOut 2 }
|
||
|
||
setJccoEntry OBJECT-TYPE
|
||
SYNTAX SetJccoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set JCC output attributes.
|
||
"
|
||
INDEX { setJccoChassis, setJccoSlot}
|
||
::= { setJccoTable 1 }
|
||
|
||
SetJccoEntry ::=
|
||
SEQUENCE {
|
||
setJccoChassis
|
||
INTEGER,
|
||
setJccoSlot
|
||
INTEGER,
|
||
setJccoBypass
|
||
OnValue,
|
||
setJcco400Hz
|
||
OnValue,
|
||
setJccoEnable
|
||
OCTET STRING,
|
||
setJccoComp
|
||
OCTET STRING
|
||
}
|
||
|
||
setJccoChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each JCC Output entry.
|
||
"
|
||
::= { setJccoEntry 1 }
|
||
|
||
setJccoSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each JCC Output entry.
|
||
"
|
||
::= { setJccoEntry 2 }
|
||
|
||
setJccoBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Clock C, or bypass mode, to enable or disable.
|
||
"
|
||
::= { setJccoEntry 3 }
|
||
|
||
setJcco400Hz OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the 400Hz BPV removal.
|
||
A setting OFF removes this 400Hz component, and a setting ON includes it.
|
||
"
|
||
::= { setJccoEntry 4 }
|
||
|
||
setJccoEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the JCC output ports to enabled or disabled.
|
||
1 = enabled
|
||
2 = disabled
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
"
|
||
::= { setJccoEntry 5 }
|
||
|
||
|
||
setJccoComp OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The array represents the output phase compensation
|
||
for all ports on an output module.
|
||
|
||
Note: Byte 1 = port 1, byte 20 = port 20.
|
||
The specifed byte value is 1 thru 8.
|
||
1 = no delay, 8 = highest delay.
|
||
|
||
The equivalent cable length:
|
||
1 = 2200 ft,
|
||
2 = 1925 ft,
|
||
3 = 1650 ft,
|
||
4 = 1375 ft,
|
||
5 = 1100 ft,
|
||
6 = 825 ft,
|
||
7 = 550 ft,
|
||
8 = 275 ft.
|
||
"
|
||
::= { setJccoEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtNtpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PackeTime NTP status and settings.
|
||
"
|
||
::= { setupPtNtp 1 }
|
||
|
||
|
||
setPtNtpEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime NTP settings and attributes.
|
||
"
|
||
INDEX { setPtNtpChassis, setPtNtpSlot}
|
||
::= { setPtNtpTable 1 }
|
||
|
||
SetPtNtpEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpChassis
|
||
INTEGER,
|
||
setPtNtpSlot
|
||
INTEGER,
|
||
setPtNtpCommit
|
||
INTEGER,
|
||
setPtNtpProbe
|
||
EnaValue,
|
||
setPtNtpBond
|
||
EnaValue,
|
||
setPtNtpNTPd
|
||
EnaValue,
|
||
setPtNtpTodsrcPrefer
|
||
INTEGER,
|
||
setPtNtpTodsrcPriority
|
||
INTEGER,
|
||
setPtNtpWeight
|
||
INTEGER,
|
||
setPtNtpCompensation
|
||
INTEGER,
|
||
setPtNtpPeerTimeout
|
||
INTEGER,
|
||
setPtNtpPeerPrefer
|
||
INTEGER,
|
||
setPtNtpBypass
|
||
OnValue,
|
||
setPtNtpModActive
|
||
YesValue,
|
||
setPtNtpPAActive
|
||
YesValue,
|
||
setPtNtpPBActive
|
||
YesValue
|
||
}
|
||
|
||
setPtNtpChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpEntry 1 }
|
||
|
||
setPtNtpSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpEntry 2 }
|
||
|
||
setPtNtpCommit OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
yes(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Commit all provisioned parameters, this action makes the parameters active.
|
||
This command will also store the parameters to non-volatile memory.
|
||
|
||
Note: This field only has meaning for a writing (1).
|
||
"
|
||
::= { setPtNtpEntry 3 }
|
||
|
||
setPtNtpProbe OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PackeTime Maintenance Port state; Enable or Disable.
|
||
|
||
This node is obsolete, The setting is NOP.
|
||
"
|
||
::= { setPtNtpEntry 4 }
|
||
|
||
|
||
setPtNtpBond OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Service port bonding state.
|
||
1 = Enabled
|
||
2 = Disabled
|
||
"
|
||
::= { setPtNtpEntry 5 }
|
||
|
||
setPtNtpNTPd OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the NTP daemon state.
|
||
1 = Enabled
|
||
2 = Disabled
|
||
"
|
||
::= { setPtNtpEntry 6 }
|
||
|
||
setPtNtpTodsrcPrefer OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
todsrc(1),
|
||
peer(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the module's preferred time-source to be either TODSRC (1) or PEER (2).
|
||
TOD Source, either the TODSRC (GPS) or a NTP Peer if operating in Client mode
|
||
"
|
||
::= { setPtNtpEntry 7 }
|
||
|
||
setPtNtpTodsrcPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Todsrc priority.
|
||
The priority is the for the specified module as the TOD Source,
|
||
default is 0, range can be 0 through 8. Value 1 is the highest,
|
||
and 8 is the lowest. If the value is zero, the specified module
|
||
cannot be TOD Source.
|
||
"
|
||
::= { setPtNtpEntry 8 }
|
||
|
||
setPtNtpWeight OBJECT-TYPE
|
||
SYNTAX INTEGER (-1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the load distribution between portA/B in percent.
|
||
For example, 70 means port-A get 70% of total bandwidth,
|
||
port-B gets remaining 30%. If port-A reaches 70% of total
|
||
bandwidth but port-B has no traffic, the 30% of bandwidth
|
||
will be wasted, port-A cannot use it. To allow either port
|
||
to use all the bandwidth, portAWeight can be set to -1,
|
||
indicating no limit between port-A and port-B (either port-A
|
||
or port-B can get all the bandwidth, based on first come
|
||
first serve). Thus the range of this parameter -1 to 100.
|
||
For bonding mode, this parameter must be forced to -1,
|
||
so the active port can use 100% of the bandwidth.
|
||
For non-bonding mode, user can set any value between -1 to 100.
|
||
"
|
||
::= { setPtNtpEntry 9 }
|
||
|
||
setPtNtpCompensation OBJECT-TYPE
|
||
SYNTAX INTEGER (0..250)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Antenna cable delay compensation
|
||
in the case of GPS ToD Source(s) or the delay induced by the cable(s) used to connect
|
||
expansion shelves where the PackeTime ToD Source(s) is located in relationship to the Main shelf.
|
||
The time offset shall have a 100nS resolution, thus the Delay value shall be multiplied
|
||
by 100nS to provide 1PPS compensation.
|
||
Valid user compensation values range is 0 thru 250 for a total compensation range of 0 to 25000nS (25uS).
|
||
"
|
||
::= { setPtNtpEntry 10 }
|
||
|
||
setPtNtpPeerTimeout OBJECT-TYPE
|
||
SYNTAX INTEGER (60..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Peer Availability Timeout
|
||
The timer shall have a user settable range from 60 minutes to 10000 minutes,
|
||
with a default value of 1440 minutes
|
||
"
|
||
::= { setPtNtpEntry 11 }
|
||
|
||
setPtNtpPeerPrefer OBJECT-TYPE
|
||
SYNTAX INTEGER (0..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the preferred peer from the peer list.
|
||
The valid value is 0-8. The value zero means, there is no prefer.
|
||
This value has meaning, only when the specified peer is in the peer list.
|
||
"
|
||
::= { setPtNtpEntry 12 }
|
||
|
||
setPtNtpBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock C state, or bypass clock, to enabled or disabled.
|
||
"
|
||
::= { setPtNtpEntry 13 }
|
||
|
||
setPtNtpModActive OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the specified module in the redundant pair to be Active.
|
||
Note1: This command only applies when the module in the redundant pair.
|
||
Note2: This field only has meaning for a writing (1).
|
||
Note3: Don't apply COMMIT after this command.
|
||
"
|
||
::= { setPtNtpEntry 14 }
|
||
|
||
setPtNtpPAActive OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Port A is being manually selected as the active port.
|
||
Note1: This command only applies when the bonding mode is enabled and both ports are in network and Ethernet link up.
|
||
Note2: This field only has meaning for a writing (1).
|
||
Note3: Don't apply COMMIT after this command.
|
||
"
|
||
::= { setPtNtpEntry 15 }
|
||
|
||
setPtNtpPBActive OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Port B is being manually selected as the active port.
|
||
Note1: This command only applies when the bonding mode is enabled and both ports are in network and Ethernet link up.
|
||
Note2: This field only has meaning for a writing (1).
|
||
Note3: Don't apply COMMIT after this command.
|
||
"
|
||
::= { setPtNtpEntry 16 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE PORT SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtNtpPortTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpPortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime NTP ethernet port information.
|
||
"
|
||
::= { setupPtNtp 2 }
|
||
|
||
|
||
setPtNtpPortEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpPortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime NTP ethernet port state and settings information.
|
||
setPtNtpPortChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtNtpPortSlot
|
||
Identifies which slot is being addressed.
|
||
setPtNtpPortNum
|
||
Identifies which port is being addressed.
|
||
setPtNtpPortAddr
|
||
Set the port IP address
|
||
setPtNtpPortMask
|
||
Set the port network mask
|
||
setPtNtpPortGate
|
||
Set the port gateway address
|
||
"
|
||
INDEX { setPtNtpPortChassis, setPtNtpPortSlot, setPtNtpPortNum}
|
||
::= { setPtNtpPortTable 1 }
|
||
|
||
SetPtNtpPortEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpPortChassis
|
||
INTEGER,
|
||
setPtNtpPortSlot
|
||
INTEGER,
|
||
setPtNtpPortNum
|
||
INTEGER,
|
||
setPtNtpPortAddr
|
||
IpAddress,
|
||
setPtNtpPortMask
|
||
IpAddress,
|
||
setPtNtpPortGate
|
||
IpAddress
|
||
}
|
||
|
||
setPtNtpPortChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpPortEntry 1 }
|
||
|
||
setPtNtpPortSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpPortEntry 2 }
|
||
|
||
setPtNtpPortNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
|
||
PTNTP ethernet interface number.
|
||
1 = Service Port A
|
||
2 = Service Port B
|
||
3 = Maintenance Port
|
||
"
|
||
::= { setPtNtpPortEntry 3 }
|
||
|
||
setPtNtpPortAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port IP address
|
||
"
|
||
::= { setPtNtpPortEntry 4 }
|
||
|
||
setPtNtpPortMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port network mask
|
||
"
|
||
::= { setPtNtpPortEntry 5 }
|
||
|
||
setPtNtpPortGate OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port gateway address
|
||
"
|
||
::= { setPtNtpPortEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE PEER SETUP GROUP
|
||
-- EXTERNAL NTP SERVER
|
||
-- ******************************************
|
||
|
||
setPtNtpPeerTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpPeerEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of PackeTime NTP Peer entries.
|
||
Entries are indexed by the values of setPtNtpPeerChassis, setPtNtpPeerSlot and setPtNtpPortNum.
|
||
"
|
||
::= { setupPtNtp 3 }
|
||
|
||
setPtNtpPeerEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpPeerEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PackeTime NTP peer state and settings.
|
||
setPtNtpPeerChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtNtpPeerSlot
|
||
Identifies which slot is being addressed.
|
||
setPtNtpPeerNum
|
||
Identifies which ntp peer is being addressed.
|
||
setPtNtpPeerAddr
|
||
Set Peer IP address in peer table.
|
||
setPtNtpPeerPmin
|
||
Set the minimum request rate in seconds for CLIENT mode.
|
||
setPtNtpPeerPmax
|
||
Set the maximum request rate in seconds for CLIENT mode.
|
||
setPtNtpPeerKeyId
|
||
Set keyId to be used to lookup authentication key,
|
||
"
|
||
INDEX { setPtNtpPeerChassis, setPtNtpPeerSlot, setPtNtpPeerNum}
|
||
::= { setPtNtpPeerTable 1 }
|
||
|
||
SetPtNtpPeerEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpPeerChassis
|
||
INTEGER,
|
||
setPtNtpPeerSlot
|
||
INTEGER,
|
||
setPtNtpPeerNum
|
||
INTEGER,
|
||
setPtNtpPeerAddr
|
||
IpAddress,
|
||
setPtNtpPeerPmin
|
||
INTEGER,
|
||
setPtNtpPeerPmax
|
||
INTEGER,
|
||
setPtNtpPeerKeyId
|
||
INTEGER
|
||
}
|
||
|
||
setPtNtpPeerChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and peer number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpPeerEntry 1 }
|
||
|
||
setPtNtpPeerSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and peer number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpPeerEntry 2 }
|
||
|
||
setPtNtpPeerNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which ntp peer is being addressed.
|
||
This chassis, slot, and peer number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpPeerEntry 3 }
|
||
|
||
setPtNtpPeerAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set Peer IP address in peer table.
|
||
Write zero IP address will delete this IP address from peer table.
|
||
"
|
||
::= { setPtNtpPeerEntry 4 }
|
||
|
||
setPtNtpPeerPmin OBJECT-TYPE
|
||
SYNTAX INTEGER (16|32|64|128|256|512|1024)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the minimum request rate in seconds for CLIENT mode,
|
||
the default is 16, the range is 16, 32, 64, 128, 256, 512, and 1024.
|
||
"
|
||
::= { setPtNtpPeerEntry 5 }
|
||
|
||
setPtNtpPeerPmax OBJECT-TYPE
|
||
SYNTAX INTEGER (16|32|64|128|256|512|1024)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the maximum request rate in seconds for CLIENT mode,
|
||
the default is 64, the range is 16, 32, 64, 128, 256, 512, and 1024.
|
||
"
|
||
::= { setPtNtpPeerEntry 6 }
|
||
|
||
setPtNtpPeerKeyId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65534)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set keyId to be used to lookup authentication key,
|
||
the default is 0 (no authentication), the range is 0 through 65534
|
||
"
|
||
::= { setPtNtpPeerEntry 7 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE AUTH SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtNtpAuthTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpAuthEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PackeTime NTP authentication entries.
|
||
The number of entries are given by the values of setPtNtpAuthChassis, setPtNtpAuthSlot and setPtNtpAuthNum.
|
||
"
|
||
::= { setupPtNtp 4 }
|
||
|
||
setPtNtpAuthEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpAuthEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PackeTime NTP authentication state and settings.
|
||
PackeTime NTP authentication attributes.
|
||
setPtNtpAuthChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtNtpAuthSlot
|
||
Identifies which slot is being addressed.
|
||
setPtNtpAuthNum
|
||
Identifies which authentication key is being addressed.
|
||
setPtNtpAuthKeyId
|
||
Set the authentication key ID,
|
||
setPtNtpAuthKeyValue
|
||
Set the NTP authentication key used to create the MD5 hash associated with the keyid.
|
||
"
|
||
INDEX { setPtNtpAuthChassis, setPtNtpAuthSlot, setPtNtpAuthNum}
|
||
::= { setPtNtpAuthTable 1 }
|
||
|
||
SetPtNtpAuthEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpAuthChassis
|
||
INTEGER,
|
||
setPtNtpAuthSlot
|
||
INTEGER,
|
||
setPtNtpAuthNum
|
||
INTEGER,
|
||
setPtNtpAuthKeyId
|
||
INTEGER,
|
||
setPtNtpAuthKeyValue
|
||
DisplayString
|
||
}
|
||
|
||
setPtNtpAuthChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and authentication key number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpAuthEntry 1 }
|
||
|
||
setPtNtpAuthSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and authentication key number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpAuthEntry 2 }
|
||
|
||
setPtNtpAuthNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..16)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which authentication key is being addressed.
|
||
This chassis, slot, and authentication key number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpAuthEntry 3 }
|
||
|
||
setPtNtpAuthKeyId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65534)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set KeyId is the authentication key ID,
|
||
default is 0 (no authentication), range 0 to 65534.
|
||
Note: If this value is zero, no authentication is used.
|
||
"
|
||
::= { setPtNtpAuthEntry 4 }
|
||
|
||
setPtNtpAuthKeyValue OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0|8..32))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the key is the NTP authentication key used to create the MD5 hash associated with the keyid.
|
||
The key is a comprised of up to 32 ASCII characters, a minimum of 8 characters is required.
|
||
Note: the key value will not display and it is always displayed as null string.
|
||
"
|
||
::= { setPtNtpAuthEntry 5 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE ROUTE SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtNtpRouteTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpRouteEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PackeTime NTP route table entries.
|
||
|
||
Static routing describes a system that does not implement adaptive routing. In these systems routes through a data
|
||
network are described by fixed paths (statically). These routes are usually entered into the host by the system
|
||
administrator.
|
||
"
|
||
::= { setupPtNtp 5 }
|
||
|
||
setPtNtpRouteEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpRouteEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A PackeTime NTP route attributes and settings.
|
||
setPtNtpRouteChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtNtpRouteSlot
|
||
Identifies which slot is being addressed.
|
||
setPtNtpRouteNum
|
||
Identifies which route number (index) is being addressed.
|
||
setPtNtpRouteAddr
|
||
Set the route destination network or destination host.
|
||
setPtNtpRouteMask
|
||
Set the netmask for the destination network.
|
||
setPtNtpRouteGate
|
||
Set the gateway ip for the destination network.
|
||
setPtNtpRouteIface
|
||
Set the module's network interface number.
|
||
"
|
||
INDEX { setPtNtpRouteChassis, setPtNtpRouteSlot, setPtNtpRouteNum}
|
||
::= { setPtNtpRouteTable 1 }
|
||
|
||
SetPtNtpRouteEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpRouteChassis
|
||
INTEGER,
|
||
setPtNtpRouteSlot
|
||
INTEGER,
|
||
setPtNtpRouteNum
|
||
INTEGER,
|
||
setPtNtpRouteAddr
|
||
IpAddress,
|
||
setPtNtpRouteMask
|
||
IpAddress,
|
||
setPtNtpRouteGate
|
||
IpAddress,
|
||
setPtNtpRouteIface
|
||
INTEGER
|
||
}
|
||
|
||
setPtNtpRouteChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and route number (index) uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpRouteEntry 1 }
|
||
|
||
setPtNtpRouteSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and route number (index) uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpRouteEntry 2 }
|
||
|
||
setPtNtpRouteNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..6)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which route number is being addressed.
|
||
This chassis, slot, and route number (index) uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpRouteEntry 3 }
|
||
|
||
setPtNtpRouteAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the route destination network or destination host.
|
||
Write a new Route IP address will put this new IP into table.
|
||
Write zero IP address will delete this IP address from table.
|
||
"
|
||
::= { setPtNtpRouteEntry 4 }
|
||
|
||
setPtNtpRouteMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the netmask for the destination network;
|
||
'255.255.255.255' for a host destination and
|
||
'0.0.0.0' for the default route
|
||
"
|
||
::= { setPtNtpRouteEntry 5 }
|
||
|
||
setPtNtpRouteGate OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the gateway for the destination network.
|
||
"
|
||
::= { setPtNtpRouteEntry 6 }
|
||
|
||
setPtNtpRouteIface OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the module's network interface number:
|
||
1 = Service Port A
|
||
2 = Service Port B
|
||
3 = Bond0 (bonding of PortA and Port B)
|
||
"
|
||
::= { setPtNtpRouteEntry 7 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME NTP MODULE VLAN SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtNtpVlanTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtNtpVlanEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of PackeTime NTP vlan attributes.
|
||
The Virtural Local Area Network is implemented per IEEE 802.1Q.
|
||
"
|
||
::= { setupPtNtp 6 }
|
||
|
||
|
||
setPtNtpVlanEntry OBJECT-TYPE
|
||
SYNTAX SetPtNtpVlanEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A PackeTime NTP vlan attributes and settings:
|
||
setPtNtpVlanChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtNtpVlanSlot
|
||
Identifies which slot is being addressed.
|
||
setPtNtpVlan
|
||
Set the VLAN state.
|
||
setPtNtpVlanPAId
|
||
Set the VLAN ID for Service Port A.
|
||
setPtNtpVlanPAPriority
|
||
Set the VLAN priority for Service Port A.
|
||
setPtNtpVlanPBId
|
||
Set the VLAN ID for Service Port B.
|
||
setPtNtpVlanPBPriority
|
||
Set the VLAN priority for Service Port B.
|
||
setPtNtpVlanBondId
|
||
Set the VLAN ID for Bonding of Service Ports of A and B
|
||
setPtNtpVlanBondPriority
|
||
Set the VLAN priority for Bonding of Service Ports of A and B
|
||
"
|
||
INDEX { setPtNtpVlanChassis, setPtNtpVlanSlot}
|
||
::= { setPtNtpVlanTable 1 }
|
||
|
||
SetPtNtpVlanEntry ::=
|
||
SEQUENCE {
|
||
setPtNtpVlanChassis
|
||
INTEGER,
|
||
setPtNtpVlanSlot
|
||
INTEGER,
|
||
setPtNtpVlan
|
||
EnaValue,
|
||
setPtNtpVlanPAId
|
||
INTEGER,
|
||
setPtNtpVlanPAPriority
|
||
INTEGER,
|
||
setPtNtpVlanPBId
|
||
INTEGER,
|
||
setPtNtpVlanPBPriority
|
||
INTEGER,
|
||
setPtNtpVlanBondId
|
||
INTEGER,
|
||
setPtNtpVlanBondPriority
|
||
INTEGER
|
||
}
|
||
|
||
setPtNtpVlanChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpVlanEntry 1 }
|
||
|
||
setPtNtpVlanSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtNtpVlanEntry 2 }
|
||
|
||
setPtNtpVlan OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN state.
|
||
1 = Enabled
|
||
2 = Disabled
|
||
"
|
||
::= { setPtNtpVlanEntry 3 }
|
||
|
||
setPtNtpVlanPAId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN ID for Service Port A, [0 - 4094]
|
||
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 4 }
|
||
|
||
setPtNtpVlanPAPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN Priority for Service Port A, [0 - 7]
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 5 }
|
||
|
||
setPtNtpVlanPBId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN ID for Service Port B, [0 - 4094]
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 6 }
|
||
|
||
|
||
setPtNtpVlanPBPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN Priority for Service Port B, [0 - 7]
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 7 }
|
||
|
||
setPtNtpVlanBondId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN ID for Bonding of Service Ports of A and B, [0 - 4094]
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 8 }
|
||
|
||
|
||
setPtNtpVlanBondPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN Priority for Bonding of Service Ports of A and B, [0 - 7]
|
||
Note: The value has no meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtNtpVlanEntry 9 }
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 GENERAL INFORMATION GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
infoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF GiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of general information entries."
|
||
::= { general 1 }
|
||
|
||
|
||
giEntry OBJECT-TYPE
|
||
SYNTAX GiEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set global module attributes.
|
||
"
|
||
INDEX { giChassis, giSlot }
|
||
::= { infoTable 1 }
|
||
|
||
|
||
GiEntry ::=
|
||
SEQUENCE {
|
||
giChassis
|
||
INTEGER,
|
||
giSlot
|
||
INTEGER,
|
||
giSystime
|
||
Counter32,
|
||
giElevation
|
||
INTEGER,
|
||
giSetup
|
||
INTEGER,
|
||
giRestart
|
||
YesValue
|
||
}
|
||
|
||
giChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { giEntry 1 }
|
||
|
||
giSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { giEntry 2 }
|
||
|
||
giSystime OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports length of time (in seconds) a specified module has been operational since last reboot.
|
||
Only apply to the CPU-based module. zero means Not Applicable.
|
||
"
|
||
::= { giEntry 3 }
|
||
|
||
giElevation OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 60..500000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The module alarm elevation time (in seconds).
|
||
Each module in the system can be set for elevation time from 60 seconds to 500,000 seconds.
|
||
A setting of 0 (zero) means no elevation for the alarm.
|
||
For example, when an alarm has been at MINOR level ontinuously for elevtime seconds, then it is elevated to the next level (MAJOR).
|
||
|
||
Note: 0 = disabled.
|
||
"
|
||
::= { giEntry 4 }
|
||
|
||
|
||
giSetup OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
factory(1),
|
||
user(2),
|
||
save(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Saves or restores the configuration of the specified module.
|
||
|
||
FACTORY - restores the module configuration to factory defaults.
|
||
SAVE - will save the current configuration as User.
|
||
USER - will restore the saved User configuration.
|
||
|
||
Note: This field only has meaning for a write operation.
|
||
Only apply to the CPU-based module.
|
||
"
|
||
::= { giEntry 5 }
|
||
|
||
|
||
giRestart OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Restarts a module.
|
||
Writing a '1' to this variable restarts (reboots) the module.
|
||
|
||
Note: This field only has meaning for a write operation.
|
||
Only apply to the CPU-based module.
|
||
"
|
||
::= { giEntry 6 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 MODULE EVENT GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
evCount OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports total number of events to display.
|
||
The number represents total number of events
|
||
we want to display. Its value ranges between
|
||
1 and 1000.
|
||
"
|
||
::= { event 1 }
|
||
|
||
evType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
alarm(1),
|
||
report(2),
|
||
all(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which event type we want to display (functions as a display filter).
|
||
Set these values to the desired type you want to display:
|
||
ALARM - for alarm type
|
||
REPORT - for event type
|
||
ALL - for all (alarm and event) type.
|
||
"
|
||
::= { event 2 }
|
||
|
||
|
||
-- ******************************************
|
||
-- EVENT TABLE
|
||
-- ******************************************
|
||
|
||
eventTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF EvEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report of system event entries.
|
||
The number of entries is given by the value of evNumber.
|
||
The total entries are up to 1000."
|
||
::= { event 3 }
|
||
|
||
|
||
evEntry OBJECT-TYPE
|
||
SYNTAX EvEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An event entry containing objects of each event."
|
||
INDEX { evIndex }
|
||
::= { eventTable 1 }
|
||
|
||
|
||
EvEntry ::=
|
||
SEQUENCE {
|
||
evIndex
|
||
INTEGER,
|
||
evT
|
||
OCTET STRING
|
||
}
|
||
|
||
evIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1000)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A unique value for each event.
|
||
This value range from 1 to 1000."
|
||
::= { evEntry 1 }
|
||
|
||
|
||
evT OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(36..116))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A OCTET STRING containing information about the event.
|
||
|
||
The string is in the TLV format, and contains
|
||
following information:
|
||
INTEGER - event id
|
||
INTEGER - module hex code
|
||
DateAndTime - timestamp
|
||
INTEGER - chassis number
|
||
INTEGER - slot number
|
||
INTEGER - port number
|
||
INTEGER - alarm code
|
||
INTEGER - notification code
|
||
INTEGER - Elevated
|
||
DisplayString - ascii string description of the event
|
||
|
||
event id:
|
||
INTEGER (0..255)
|
||
|
||
Alarm Code:
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5),
|
||
|
||
Notification Code:
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5),
|
||
clear(6)
|
||
|
||
Elevated:
|
||
Yes(1),
|
||
No(2)
|
||
"
|
||
::= { evEntry 2 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 ALARM GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- **************************************************************
|
||
-- ALARM STATUS TABLE
|
||
-- **************************************************************
|
||
|
||
alarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AlmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of alarm entries.
|
||
"
|
||
::= { alarm 1 }
|
||
|
||
almEntry OBJECT-TYPE
|
||
SYNTAX AlmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Alarm entry attributes.
|
||
"
|
||
INDEX { almChassis, almSlot, almPort, almIndex }
|
||
::= { alarmTable 1 }
|
||
|
||
AlmEntry ::=
|
||
SEQUENCE {
|
||
almChassis
|
||
INTEGER,
|
||
almSlot
|
||
INTEGER,
|
||
almPort
|
||
INTEGER,
|
||
almIndex
|
||
INTEGER,
|
||
almId
|
||
INTEGER,
|
||
almName
|
||
DisplayString,
|
||
almLevel
|
||
INTEGER,
|
||
almElevate
|
||
YesValue,
|
||
almStatus
|
||
DisplayString
|
||
}
|
||
|
||
almChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { almEntry 1 }
|
||
|
||
almSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { almEntry 2 }
|
||
|
||
|
||
almPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { almEntry 3 }
|
||
|
||
almIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..32)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the alarm index value.
|
||
|
||
Note: The alarm id is allowed for number zero; therefore,
|
||
the OID for this index is alarm id plus 1 to avoid the zero number for OID.
|
||
"
|
||
::= { almEntry 4 }
|
||
|
||
almId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..31)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the alarm id.
|
||
|
||
Note: This is the actual alarm id range 0 thru 31.
|
||
"
|
||
::= { almEntry 5 }
|
||
|
||
almName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the text string to describe this alarm.
|
||
"
|
||
::= { almEntry 6 }
|
||
|
||
almLevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5),
|
||
clear(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports current state of alarm indications on the units.
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5),
|
||
clear(6)
|
||
"
|
||
::= { almEntry 7 }
|
||
|
||
|
||
almElevate OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report alarm elevation state
|
||
|
||
1 = alarm elevated
|
||
2 = alarm not elevated
|
||
"
|
||
::= { almEntry 8 }
|
||
|
||
almStatus OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the text string to describe this alarm status condition.
|
||
"
|
||
::= { almEntry 9 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- ALARM SET GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
--
|
||
-- MODULE ALARM SETTING
|
||
-- IT SHOULD BE ONE MODULE, MULTIPLE MODULE IS NOT ALLOWED
|
||
|
||
setAlmLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the module slot location.
|
||
It should be one module, multiple module is not allowed
|
||
where
|
||
x is the chassis number: the range is 1 to 5,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number. range is [1 to 20].
|
||
|
||
For example: 1A3-1 for module located in chassis 1 and slot 3, port 1.
|
||
|
||
Note: The slot location must be physically installed in the unit.
|
||
"
|
||
::= { alarm 2 }
|
||
|
||
|
||
-- ******************************************
|
||
-- ALARM SETTING TABLE
|
||
-- ******************************************
|
||
|
||
setAlmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SalEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of alarm entries.
|
||
"
|
||
::= { alarm 3 }
|
||
|
||
salEntry OBJECT-TYPE
|
||
SYNTAX SalEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set alarm attributes.
|
||
"
|
||
INDEX { salChassis, salSlot, salPort, salIndex }
|
||
::= { setAlmTable 1 }
|
||
|
||
|
||
SalEntry ::=
|
||
SEQUENCE {
|
||
salChassis
|
||
INTEGER,
|
||
salSlot
|
||
INTEGER,
|
||
salPort
|
||
INTEGER,
|
||
salIndex
|
||
INTEGER,
|
||
salId
|
||
INTEGER,
|
||
salName
|
||
DisplayString,
|
||
salSet
|
||
YesValue,
|
||
salElevate
|
||
YesValue,
|
||
salLevel
|
||
INTEGER,
|
||
salDelay
|
||
INTEGER
|
||
}
|
||
|
||
salChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { salEntry 1 }
|
||
|
||
salSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { salEntry 2 }
|
||
|
||
|
||
salPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { salEntry 3 }
|
||
|
||
salIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..32)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index value for the alarm.
|
||
|
||
Note: The alarm id is allowed for number zero;
|
||
therefore, the OID for this index is alarm id plus 1 to avoid the zero number for OID.
|
||
"
|
||
::= { salEntry 4 }
|
||
|
||
salId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..31)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"ID value for the alarm.
|
||
|
||
Note: This is the actual alarm id range 0 thru 31.
|
||
"
|
||
::= { salEntry 5 }
|
||
|
||
salName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Name/Description for the alarm.
|
||
"
|
||
::= { salEntry 6 }
|
||
|
||
salSet OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Alarm state for the alarm:
|
||
|
||
1 = alarm set
|
||
2 = no alarm
|
||
"
|
||
::= { salEntry 7 }
|
||
|
||
salElevate OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Alarm elevation status:
|
||
|
||
1 = alarm elevated
|
||
2 = alarm not elevated
|
||
"
|
||
::= { salEntry 8 }
|
||
|
||
salLevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets alarm severe level are:
|
||
MINOR - sets alarm level to MINOR
|
||
MAJOR - set alarm level to MAJOR
|
||
CRITICAL - sets alarm level to CRITICAL
|
||
IGNORE - ignore any alarm indication
|
||
REPORT - report only any alarm indication
|
||
"
|
||
::= { salEntry 9 }
|
||
|
||
salDelay OBJECT-TYPE
|
||
SYNTAX INTEGER (-1 | 0..86400)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the length of time in seconds an alarm must be active before generating an alarm.
|
||
|
||
Note:
|
||
0 = user selected immediate indication
|
||
-1 (when read) = forced immediate indication (i.e. not user selectable)
|
||
"
|
||
::= { salEntry 10 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 REF GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
refClk OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
none(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set which clk is currently selected.
|
||
clka(1),
|
||
clkb(2),
|
||
none(3)
|
||
|
||
Note: When read, it shows which clock is currently selected.
|
||
When write, only clka or clkb are valid.
|
||
"
|
||
::= { ref 1 }
|
||
|
||
refInp OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the input reference port.
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1.
|
||
The NULL string means there is no input reference.
|
||
"
|
||
::= { ref 2 }
|
||
|
||
refBypass OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set input port designated as the input bypass clock.
|
||
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1.
|
||
The NULL string means there is no bypass clock.
|
||
|
||
Note: In the SSU2000, the input module always resides in the main chassis (i.e. 'x' is one).
|
||
"
|
||
::= { ref 3 }
|
||
|
||
refClkSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ar(1),
|
||
off(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set Clock auto-return (AR) mode.
|
||
ar(1),
|
||
off(2)
|
||
The AR option changes the current clock selection mode to revertive operation.
|
||
"
|
||
::= { ref 4 }
|
||
|
||
refInpSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ar(1),
|
||
as(2),
|
||
off(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set input switch mode.
|
||
The InpSwitch settings are:
|
||
|
||
AR = Auto Return (revertive)
|
||
AS = Auto Switch (but not revertive)
|
||
OFF = No auto switching
|
||
"
|
||
::= { ref 5 }
|
||
|
||
refInpSelection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
priority(1),
|
||
pql(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set input selection mode.
|
||
The input reference selection can be PRIORITY/ PQL.
|
||
|
||
PRIORITY - the user assigned priority number is used to
|
||
pick the best input port as an input reference.
|
||
PQL - the input Priority Quality Level (PQL) is used to
|
||
select which is the best input port reference.
|
||
"
|
||
::= { ref 6 }
|
||
|
||
refClkTodsrc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set TOD Source.
|
||
The value can be any TOD source candidate (GPS or PackeTime) indicates the TODSRC of the selected clock.
|
||
|
||
The text string of the todsrc reference port.
|
||
The format is defined as xAy.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
|
||
For example: 1A3 means this reference located at chassis 1, slot 3.
|
||
The NULL string means there is no reference.
|
||
"
|
||
::= { ref 7 }
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 PHASE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
|
||
-- **************************************************************
|
||
-- CURRENT PHASE TABLE
|
||
-- **************************************************************
|
||
|
||
phaseTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PhEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of phase data entries.
|
||
"
|
||
::= { phase 1 }
|
||
|
||
|
||
phEntry OBJECT-TYPE
|
||
SYNTAX PhEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Phase data entry attributes.
|
||
"
|
||
INDEX { phChassis, phSlot, phPort }
|
||
::= { phaseTable 1 }
|
||
|
||
|
||
PhEntry ::=
|
||
SEQUENCE {
|
||
phChassis
|
||
INTEGER,
|
||
phSlot
|
||
INTEGER,
|
||
phPort
|
||
INTEGER,
|
||
phA
|
||
OCTET STRING,
|
||
phB
|
||
OCTET STRING,
|
||
ph100A
|
||
OCTET STRING,
|
||
ph100B
|
||
OCTET STRING,
|
||
ph1000A
|
||
OCTET STRING,
|
||
ph1000B
|
||
OCTET STRING,
|
||
ph10000A
|
||
OCTET STRING,
|
||
ph10000B
|
||
OCTET STRING
|
||
}
|
||
|
||
phChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phEntry 1 }
|
||
|
||
phSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phEntry 2 }
|
||
|
||
phPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phEntry 3 }
|
||
|
||
phA OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 1-second phase value in nanoseconds on clock A.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 4 }
|
||
|
||
phB OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 1-second phase value in nanoseconds on clock B.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 5 }
|
||
|
||
|
||
ph100A OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 100-second phase value in nanoseconds on clock A.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 6 }
|
||
|
||
ph100B OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 100-second phase value in nanoseconds on clock B.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 7 }
|
||
|
||
ph1000A OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 1000-second phase value in nanoseconds on clock A.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 8 }
|
||
|
||
ph1000B OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 1000-second phase value in nanoseconds on clock B.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 9 }
|
||
|
||
|
||
ph10000A OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 10000-second phase value in nanoseconds on clock A.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 10 }
|
||
|
||
ph10000B OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current 10000-second phase value in nanoseconds on clock B.
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and contains following information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phEntry 11 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- PHASE HISTORY GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS (PHASE HISTORY)
|
||
-- ******************************************
|
||
|
||
phHisInpLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select input port.
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1
|
||
|
||
Note: the user must specify valid input port address.
|
||
The valid port must be physically installed in the system.
|
||
|
||
Note: In the SSU2000, the input is located at main chassis, the 'x' number is always one.
|
||
"
|
||
::= { phase 2 }
|
||
|
||
phHisTimeAvg OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
t100 (100), --- 100 second time interval
|
||
t1000 (1000), --- 1000 second time interval
|
||
t10000 (10000) --- 10000 second time interval
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports time (seconds) interval of phase value.
|
||
t1 (4000 second time interval),
|
||
t100 (1000 second time interval),
|
||
t1000 (1000 second time interval),
|
||
t10000 (10000 second time interval)
|
||
|
||
Note: T1 data is only available for ports configured for this function, maximum of 5 ports.
|
||
"
|
||
::= { phase 3 }
|
||
|
||
phHisClk OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka (1),
|
||
clkb (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock is used as the reference in the phase measurement.
|
||
"
|
||
::= { phase 4 }
|
||
|
||
phHisCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..7000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Count of phase measurement history requested from the phase history buffer.
|
||
The maximum phase history in buffer are:
|
||
T100 = 7000,
|
||
T1000 = 700,
|
||
T10000 = 70,
|
||
|
||
Default value = 10.
|
||
"
|
||
::= { phase 5 }
|
||
|
||
|
||
-- ******************************************
|
||
-- PHASE HISTORY TABLE
|
||
-- ******************************************
|
||
|
||
phHisTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PhHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of phase history entries. The number of entries is
|
||
given by the value of phHisCnt. The total entries
|
||
are up to 7000.
|
||
|
||
Note: this table is based upon the following values:
|
||
phHisInpLoc - the location of the input port
|
||
phHisTimeAvg - the time (seconds) interval of phase value
|
||
phHisCnt - total amount of phase history to return.
|
||
"
|
||
::= { phase 6 }
|
||
|
||
|
||
|
||
phHisEntry OBJECT-TYPE
|
||
SYNTAX PhHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A phase entry attributes:
|
||
phHisChassis
|
||
Identifies which chassis is being addressed.
|
||
phHisSlot
|
||
Identifies which slot is being addressed.
|
||
phHisPort
|
||
Identifies which port is being addressed.
|
||
phHisIndex
|
||
Count/ID value for each phase.
|
||
phHisV
|
||
Phase value in nanoseconds defined in phHisTimeAvg.
|
||
"
|
||
INDEX { phHisChassis, phHisSlot, phHisPort, phHisIndex }
|
||
::= { phHisTable 1 }
|
||
|
||
PhHisEntry ::=
|
||
SEQUENCE {
|
||
phHisChassis
|
||
INTEGER,
|
||
phHisSlot
|
||
INTEGER,
|
||
phHisPort
|
||
INTEGER,
|
||
phHisIndex
|
||
INTEGER,
|
||
phHisV
|
||
OCTET STRING
|
||
}
|
||
|
||
|
||
phHisChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phHisEntry 1 }
|
||
|
||
phHisSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phHisEntry 2 }
|
||
|
||
phHisPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { phHisEntry 3 }
|
||
|
||
phHisIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..7000)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Count/ID value for each phase.
|
||
Valid range : 1 - 7000.
|
||
"
|
||
::= { phHisEntry 4 }
|
||
|
||
|
||
phHisV OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Phase value in nanoseconds defined in phHisTimeAvg.
|
||
|
||
The 1,999,999,999 is designated for invalid phase value.
|
||
|
||
The string is in the TLV format, and containsfollowing information:
|
||
DateAndTime - timestamp
|
||
INTEGER - phase value
|
||
"
|
||
::= { phHisEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 MTIE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- **************************************************************
|
||
-- CURRENT MTIE GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
mtInpLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (3..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select input port.
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1.
|
||
For example: 1A3 means this input port located at chassis 1, slot 3, with all port specified.
|
||
"
|
||
::= { mtie 1 }
|
||
|
||
|
||
mtFrTime OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select starting time to measure the MTIE from.
|
||
|
||
Note: the default time is defined as last 24 hours from current time.
|
||
The default start-time is the current time minus 24 hours, and the default stop-time is the current time.
|
||
"
|
||
::= { mtie 2 }
|
||
|
||
mtToTime OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select the stop-time to measure the MTIE.
|
||
If the 'year' field of DateAndTime is specified as zero, the default time is used.
|
||
|
||
The default mtToTime is the current time.
|
||
"
|
||
::= { mtie 3 }
|
||
|
||
|
||
-- ******************************************
|
||
-- CURRENT MTIE TABLE
|
||
-- ******************************************
|
||
|
||
mtTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF MtEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report the MTIE measurement.
|
||
"
|
||
::= { mtie 5 }
|
||
|
||
mtEntry OBJECT-TYPE
|
||
SYNTAX MtEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A mtie record attributes:
|
||
mtChassis
|
||
Identifies which chassis is being addressed.
|
||
mtSlot
|
||
Identifies which slot is being addressed.
|
||
mtPort
|
||
Identifies which port is being addressed.
|
||
mtA
|
||
MTIE record versus clock A.
|
||
mtB
|
||
MTIE record versus clock B.
|
||
"
|
||
INDEX { mtChassis, mtSlot, mtPort }
|
||
::= { mtTable 1 }
|
||
|
||
MtEntry ::=
|
||
SEQUENCE {
|
||
mtChassis
|
||
INTEGER,
|
||
mtSlot
|
||
INTEGER,
|
||
mtPort
|
||
INTEGER,
|
||
mtA
|
||
OCTET STRING,
|
||
mtB
|
||
OCTET STRING
|
||
}
|
||
|
||
|
||
mtChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtEntry 1 }
|
||
|
||
mtSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtEntry 2 }
|
||
|
||
mtPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtEntry 3 }
|
||
|
||
mtA OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(76))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MTIE record versus clock A.
|
||
|
||
The MTIE record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.05 second measurement value
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
INTEGER - 100000 second measurement value
|
||
note: if a non-deterministic value is used in this field, a
|
||
mtie value will be displayed as -1 (i.e. invalid value).
|
||
"
|
||
::= { mtEntry 4 }
|
||
|
||
mtB OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(76))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MTIE record versus clock B.
|
||
|
||
The MTIE record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.05 second measurement value
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
INTEGER - 100000 second measurement value
|
||
note: if a non-deterministic value is used in this field, a
|
||
mtie value will be displayed as -1 (i.e. invalid value).
|
||
"
|
||
::= { mtEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- MTIE HISTORY GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
mtHisInpLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select the input port.
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1.
|
||
|
||
Note: the user must specify valid input port address.
|
||
The valid port is single port and must be physically installed in the system.
|
||
Multiple ports are not valid.
|
||
"
|
||
::= { mtie 6 }
|
||
|
||
mtHisClk OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka (1),
|
||
clkb (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clock reference used for reporting of MTIE History.
|
||
"
|
||
::= { mtie 7 }
|
||
|
||
mtHisCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Number of days of MTIE History to report.
|
||
The range = 1 - 100.
|
||
Default value for this field = 1.
|
||
"
|
||
::= { mtie 8 }
|
||
|
||
|
||
-- ******************************************
|
||
-- MTIE HISTORY TABLE
|
||
-- ******************************************
|
||
|
||
mtHisTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF MtHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of mtie history entries.
|
||
|
||
Note: this table is based upon the following values:
|
||
mtHisInpLoc - the location of the input port
|
||
mtHisCnt - total number of mtie hostory want to query.
|
||
"
|
||
::= { mtie 9 }
|
||
|
||
|
||
mtHisEntry OBJECT-TYPE
|
||
SYNTAX MtHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MTIE 24-hours history attributes.
|
||
mtHisChassis
|
||
Identifies which chassis is being addressed.
|
||
mtHisSlot
|
||
Identifies which slot is being addressed.
|
||
mtHisPort
|
||
Identifies which port is being addressed.
|
||
mtHisIndex
|
||
Index for the MTIE record.
|
||
mtHisV
|
||
MTIE record versus selected clock.
|
||
"
|
||
INDEX { mtHisChassis, mtHisSlot, mtHisPort, mtHisIndex }
|
||
::= { mtHisTable 1 }
|
||
|
||
|
||
MtHisEntry ::=
|
||
SEQUENCE {
|
||
mtHisChassis
|
||
INTEGER,
|
||
mtHisSlot
|
||
INTEGER,
|
||
mtHisPort
|
||
INTEGER,
|
||
mtHisIndex
|
||
INTEGER,
|
||
mtHisV
|
||
OCTET STRING
|
||
}
|
||
|
||
mtHisChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtHisEntry 1 }
|
||
|
||
mtHisSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtHisEntry 2 }
|
||
|
||
mtHisPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { mtHisEntry 3 }
|
||
|
||
mtHisIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for the MTIE record.
|
||
Valid range = 1 - 100.
|
||
"
|
||
::= { mtHisEntry 4 }
|
||
|
||
|
||
mtHisV OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(76))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MTIE record versus selected clock.
|
||
|
||
The MTIE record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.05 second measurement value
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
INTEGER - 100000 second measurement value
|
||
note: if a non-deterministic value is used in this field, a
|
||
mtie value will be displayed as -1 (i.e. invalid value).
|
||
"
|
||
::= { mtHisEntry 5 }
|
||
|
||
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 TDEV GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- **************************************************************
|
||
-- CURRENT TDEV GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
tdInpLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (3..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select input port.
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1.
|
||
For example: 1A3 means this input port located at hassis 1, slot 3, with all port specified.
|
||
"
|
||
::= { tdev 1 }
|
||
|
||
tdFrTime OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select starting time to measure the TDEV from.
|
||
|
||
Note: the default time is defined as last 24 hours from current time.
|
||
The default start-time is the current time minus 24 hours, and the default stop-time is the current time.
|
||
"
|
||
::= { tdev 2 }
|
||
|
||
tdToTime OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Select stop time to measure the TDEV from.
|
||
|
||
Note: the default time is the current time.
|
||
"
|
||
::= { tdev 3 }
|
||
|
||
|
||
-- ******************************************
|
||
-- CURRENT TDEV TABLE
|
||
-- ******************************************
|
||
|
||
tdTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF TdEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report the TDEV measurement.
|
||
"
|
||
::= { tdev 5 }
|
||
|
||
tdEntry OBJECT-TYPE
|
||
SYNTAX TdEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A mtie record attributes:
|
||
tdChassis
|
||
Identifies which chassis is being addressed.
|
||
tdSlot
|
||
Identifies which slot is being addressed.
|
||
tdPort
|
||
Identifies which port is being addressed.
|
||
tdA
|
||
TDEV record versus clock A.
|
||
tdB
|
||
TDEV record versus clock B.
|
||
"
|
||
INDEX { tdChassis, tdSlot, tdPort }
|
||
::= { tdTable 1 }
|
||
|
||
TdEntry ::=
|
||
SEQUENCE {
|
||
tdChassis
|
||
INTEGER,
|
||
tdSlot
|
||
INTEGER,
|
||
tdPort
|
||
INTEGER,
|
||
tdA
|
||
OCTET STRING,
|
||
tdB
|
||
OCTET STRING
|
||
}
|
||
|
||
tdChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdEntry 1 }
|
||
|
||
tdSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdEntry 2 }
|
||
|
||
tdPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdEntry 3 }
|
||
|
||
|
||
tdA OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(124))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"TDEV record versus clock A:
|
||
|
||
TDEV record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 0.3 second measurement value
|
||
INTEGER - 0.6 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 3 second measurement value
|
||
INTEGER - 6 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 30 second measurement value
|
||
INTEGER - 60 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 300 second measurement value
|
||
INTEGER - 600 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 3000 second measurement value
|
||
INTEGER - 6000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
|
||
Note: The value are for the time period, the value provided are multpled by 100 times,
|
||
to avoid floating number representaion.
|
||
"
|
||
::= { tdEntry 4 }
|
||
|
||
tdB OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(124))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"TDEV record versus clock B:
|
||
|
||
TDEV record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 0.3 second measurement value
|
||
INTEGER - 0.6 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 3 second measurement value
|
||
INTEGER - 6 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 30 second measurement value
|
||
INTEGER - 60 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 300 second measurement value
|
||
INTEGER - 600 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 3000 second measurement value
|
||
INTEGER - 6000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
|
||
Note: The value are for the time period, the value provided are multpled by 100 times,
|
||
to avoid floating number representaion.
|
||
"
|
||
::= { tdEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- TDEV HISTORY GROUP
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
tdHisInpLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Selected input port.
|
||
|
||
The format is defined as xAy-z.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3).
|
||
|
||
For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1
|
||
|
||
Note: the user must specify valid input port address.
|
||
The valid port is single port and must be physically installed in the system.
|
||
Multiple ports are not valid.
|
||
"
|
||
::= { tdev 6 }
|
||
|
||
tdHisClk OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka (1),
|
||
clkb (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set which clock is used to make the TDEV measurement.
|
||
"
|
||
::= { tdev 7 }
|
||
|
||
tdHisCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the number of days of TDEV History to report.
|
||
The range = 1 - 100.
|
||
Default value for this field = 1.
|
||
"
|
||
::= { tdev 8 }
|
||
|
||
|
||
-- ******************************************
|
||
-- TDEV HISTORY TABLE
|
||
-- ******************************************
|
||
|
||
tdHisTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF TdHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of tdev history entries.
|
||
|
||
Note: this table is based upon the following values:
|
||
tdHisInpLoc - the location of the input port
|
||
tdHisCnt - total number of tdev hostory want to query.
|
||
"
|
||
::= { tdev 9 }
|
||
|
||
|
||
tdHisEntry OBJECT-TYPE
|
||
SYNTAX TdHisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"TDEV 24-hours history attributes.
|
||
tdHisChassis
|
||
Identifies which chassis is being addressed.
|
||
tdHisSlot
|
||
Identifies which slot is being addressed.
|
||
tdHisPort
|
||
Identifies which port is being addressed.
|
||
tdHisIndex
|
||
Index for the TDEV record.
|
||
tdHisV
|
||
TDEV record versus selected clock.
|
||
"
|
||
INDEX { tdHisChassis, tdHisSlot, tdHisPort, tdHisIndex }
|
||
::= { tdHisTable 1 }
|
||
|
||
|
||
TdHisEntry ::=
|
||
SEQUENCE {
|
||
tdHisChassis
|
||
INTEGER,
|
||
tdHisSlot
|
||
INTEGER,
|
||
tdHisPort
|
||
INTEGER,
|
||
tdHisIndex
|
||
INTEGER,
|
||
tdHisV
|
||
OCTET STRING
|
||
}
|
||
|
||
tdHisChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdHisEntry 1 }
|
||
|
||
tdHisSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdHisEntry 2 }
|
||
|
||
tdHisPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { tdHisEntry 3 }
|
||
|
||
tdHisIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index value for the TDEV history record.
|
||
Valid range = 1 - 100.
|
||
"
|
||
::= { tdHisEntry 4 }
|
||
|
||
|
||
tdHisV OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(124))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"TDEV record versus selected clock.
|
||
|
||
The TDEV record attributes:
|
||
INTEGER - entry valid ?, 1=valid, 2=invalid
|
||
DateAndTime - the staring timestamp
|
||
DateAndTime - the ending timestamp
|
||
INTEGER - which clock, 1=clka, 2=clkb
|
||
INTEGER - 0.1 second measurement value
|
||
INTEGER - 0.3 second measurement value
|
||
INTEGER - 0.6 second measurement value
|
||
INTEGER - 1 second measurement value
|
||
INTEGER - 3 second measurement value
|
||
INTEGER - 6 second measurement value
|
||
INTEGER - 10 second measurement value
|
||
INTEGER - 30 second measurement value
|
||
INTEGER - 60 second measurement value
|
||
INTEGER - 100 second measurement value
|
||
INTEGER - 300 second measurement value
|
||
INTEGER - 600 second measurement value
|
||
INTEGER - 1000 second measurement value
|
||
INTEGER - 3000 second measurement value
|
||
INTEGER - 6000 second measurement value
|
||
INTEGER - 10000 second measurement value
|
||
|
||
Note: The value are for the time period, the value provided are multpled by 100 times,
|
||
to avoid floating number representaion.
|
||
"
|
||
::= { tdHisEntry 5 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 FREQ GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
freqTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF FqEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of frequency entries for each input port.
|
||
"
|
||
::= { freq 1 }
|
||
|
||
|
||
fqEntry OBJECT-TYPE
|
||
SYNTAX FqEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Frequency entry attributes:
|
||
fqChassis
|
||
INTEGER,
|
||
fqSlot
|
||
INTEGER,
|
||
fqPort
|
||
INTEGER,
|
||
fqA
|
||
OCTET STRING,
|
||
fqB
|
||
"
|
||
INDEX { fqChassis, fqSlot, fqPort }
|
||
::= { freqTable 1 }
|
||
|
||
|
||
FqEntry ::=
|
||
SEQUENCE {
|
||
fqChassis
|
||
INTEGER,
|
||
fqSlot
|
||
INTEGER,
|
||
fqPort
|
||
INTEGER,
|
||
fqA
|
||
OCTET STRING,
|
||
fqB
|
||
OCTET STRING
|
||
}
|
||
|
||
fqChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { fqEntry 1 }
|
||
|
||
fqSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { fqEntry 2 }
|
||
|
||
fqPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { fqEntry 3 }
|
||
|
||
|
||
fqA OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current frequency measurement versus clock A.
|
||
The 1,999,999,999 is designated for invalid frequency value.
|
||
|
||
DateAndTime - timestamp
|
||
INTEGER - frequency value
|
||
"
|
||
::= { fqEntry 4 }
|
||
|
||
fqB OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current frequency measurement versus clock B.
|
||
The 1,999,999,999 is designated for invalid frequency value.
|
||
|
||
DateAndTime - timestamp
|
||
INTEGER - frequency value
|
||
"
|
||
::= { fqEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 NTP GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
ntpMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
server(1),
|
||
client(2),
|
||
local(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current NTP mode in the system.
|
||
|
||
SERVER - The system has a GPS module installed and has UTC time.
|
||
|
||
CLIENT - The system has a valid Client peer entry in the NTP Table,
|
||
and is synced with its associated Server.
|
||
|
||
LOCAL - The sytem is running its own clock and has its own time.
|
||
"
|
||
::= { ntp 1 }
|
||
|
||
ntpSysPeer OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This is the system peer IP address.
|
||
"
|
||
::= { ntp 2 }
|
||
|
||
ntpSysPeerOffset OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This is the system peer offset.
|
||
"
|
||
::= { ntp 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 NTP PEER STATUS TABLE
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
peerStaTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PeerStaEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This is the peer statistics table."
|
||
::= { ntp 4 }
|
||
|
||
peerStaEntry OBJECT-TYPE
|
||
SYNTAX PeerStaEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A peer statistics attributes:
|
||
peerStaIndex
|
||
Reports index for each peer statistics table.
|
||
peerStaAddress
|
||
Reports the peer IP address.
|
||
peerStaHomeMode
|
||
Reports the peer NTP mode.
|
||
peerStaParentMode
|
||
Reports the parent NTP mode.
|
||
peerStaLeap
|
||
Reports leap indicator state.
|
||
peerStaStratum
|
||
Reports peer stratum level.
|
||
peerStaPrecision
|
||
Reports peer precision.
|
||
peerStaDelay
|
||
Reports peer delay.
|
||
peerStaDispersion
|
||
Reports peer dispersion.
|
||
peerStaOffset
|
||
Reports peer offset.
|
||
peerStaSentCnt
|
||
Reports peer sent counter.
|
||
peerStaProcessCnt
|
||
Reports peer process counter.
|
||
peerStaSanity
|
||
Reports status of peer sanity.
|
||
"
|
||
INDEX { peerStaIndex }
|
||
::= { peerStaTable 1 }
|
||
|
||
|
||
PeerStaEntry ::=
|
||
SEQUENCE {
|
||
peerStaIndex
|
||
INTEGER,
|
||
peerStaAddress
|
||
IpAddress,
|
||
peerStaHomeMode
|
||
INTEGER,
|
||
peerStaParentMode
|
||
INTEGER,
|
||
peerStaLeap
|
||
INTEGER,
|
||
peerStaStratum
|
||
INTEGER,
|
||
peerStaPrecision
|
||
INTEGER,
|
||
peerStaDelay
|
||
DisplayString,
|
||
peerStaDispersion
|
||
DisplayString,
|
||
peerStaOffset
|
||
DisplayString,
|
||
peerStaSentCnt
|
||
Counter32,
|
||
peerStaProcessCnt
|
||
Counter32,
|
||
peerStaSanity
|
||
YesValue
|
||
}
|
||
|
||
peerStaIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports index for each peer statistics table.
|
||
This value ranges from 1 to 8."
|
||
::= { peerStaEntry 1 }
|
||
|
||
peerStaAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the peer IP address.
|
||
"
|
||
::= { peerStaEntry 2 }
|
||
|
||
peerStaHomeMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unspect(0),
|
||
active(1),
|
||
passive(2),
|
||
client(3),
|
||
server(4),
|
||
broadcast(5),
|
||
control(6),
|
||
private(7),
|
||
bclient(8)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the peer NTP mode.
|
||
unspect(0),
|
||
active(1),
|
||
passive(2),
|
||
client(3),
|
||
server(4),
|
||
broadcast(5),
|
||
control(6),
|
||
private(7),
|
||
bclient(8)
|
||
"
|
||
::= { peerStaEntry 3 }
|
||
|
||
peerStaParentMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unspect(0),
|
||
active(1),
|
||
passive(2),
|
||
client(3),
|
||
server(4),
|
||
broadcast(5),
|
||
control(6),
|
||
private(7),
|
||
bclient(8)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the peer parent NTP mode.
|
||
unspect(0),
|
||
active(1),
|
||
passive(2),
|
||
client(3),
|
||
server(4),
|
||
broadcast(5),
|
||
control(6),
|
||
private(7),
|
||
bclient(8)
|
||
"
|
||
::= { peerStaEntry 4 }
|
||
|
||
peerStaLeap OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
nowarning(0),
|
||
addsec(1),
|
||
delsec(2),
|
||
notinsync(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports leap indicator state.
|
||
Valid values are:
|
||
0 = sync'd, no warning
|
||
1 = 1 second will be added
|
||
2 = 1 second will be subtracted
|
||
3 = not sync'd
|
||
"
|
||
::= { peerStaEntry 5 }
|
||
|
||
|
||
peerStaStratum OBJECT-TYPE
|
||
SYNTAX INTEGER (0 | 1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer stratum level.
|
||
If zero, it is invalid.
|
||
"
|
||
::= { peerStaEntry 6 }
|
||
|
||
peerStaPrecision OBJECT-TYPE
|
||
SYNTAX INTEGER (-1000..1000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer precision.
|
||
"
|
||
::= { peerStaEntry 7 }
|
||
|
||
peerStaDelay OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer delay.
|
||
"
|
||
::= { peerStaEntry 8 }
|
||
|
||
peerStaDispersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer dispersion.
|
||
"
|
||
::= { peerStaEntry 9 }
|
||
|
||
peerStaOffset OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer offset.
|
||
"
|
||
::= { peerStaEntry 10 }
|
||
|
||
peerStaSentCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer sent counter.
|
||
"
|
||
::= { peerStaEntry 11 }
|
||
|
||
peerStaProcessCnt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports peer process counter.
|
||
"
|
||
::= { peerStaEntry 12 }
|
||
|
||
peerStaSanity OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports status of peer sanity:
|
||
1 = passed
|
||
2 = rejected
|
||
"
|
||
::= { peerStaEntry 13 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 NTP IP TABLE
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
ntpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF NtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table provides the NTP peer statistics.
|
||
"
|
||
::= { ntp 5 }
|
||
|
||
|
||
ntpEntry OBJECT-TYPE
|
||
SYNTAX NtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"NTP peer attributes.
|
||
ntpIndex
|
||
Index for each NTP peer entry.
|
||
ntpPeer
|
||
Reports NTP peer IP address.
|
||
ntpPeerType
|
||
Report NTP peer mode.
|
||
ntpBrdTimer
|
||
Report NTP broadcast timer
|
||
"
|
||
INDEX { ntpIndex }
|
||
::= { ntpTable 1 }
|
||
|
||
|
||
NtpEntry ::=
|
||
SEQUENCE {
|
||
ntpIndex
|
||
INTEGER,
|
||
ntpPeer
|
||
IpAddress,
|
||
ntpPeerType
|
||
INTEGER,
|
||
ntpBrdTimer
|
||
INTEGER
|
||
}
|
||
|
||
ntpIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each NTP peer entry.
|
||
This value ranges from 1 to 3."
|
||
::= { ntpEntry 1 }
|
||
|
||
|
||
ntpPeer OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports NTP peer IP address.
|
||
If the ip address is zero for this entry, the whole entry has no meaning.
|
||
"
|
||
::= { ntpEntry 2 }
|
||
|
||
ntpPeerType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
client (1),
|
||
broadcast (2),
|
||
bclient (3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report NTP peer mode.
|
||
|
||
CLIENT - The IP for NTP server in client mode.
|
||
BROADCAST - The subnet mask for broadcasting mode.
|
||
BCLIENT - The IP for NTP server in broadcast client mode.
|
||
"
|
||
::= { ntpEntry 3 }
|
||
|
||
|
||
ntpBrdTimer OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
notuse(0),
|
||
t32 (32),
|
||
t64 (64),
|
||
t128 (128),
|
||
t256 (256),
|
||
t512 (512),
|
||
t1024 (1024)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report NTP broadcast timer in
|
||
notuse(0),
|
||
t32 (32),
|
||
t64 (64),
|
||
t128 (128),
|
||
t256 (256),
|
||
t512 (512),
|
||
t1024 (1024)
|
||
"
|
||
::= { ntpEntry 4 }
|
||
|
||
|
||
-- ******************************************
|
||
-- NTP SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
ntpAddClient OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set NTP peers to enable client mode.
|
||
|
||
This field has meaning only during 'write' operations.
|
||
"
|
||
::= { ntp 6 }
|
||
|
||
ntpAddBrd OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set NTP servers to enable broadcast mode.
|
||
|
||
This field has meaning only during 'write' operations.
|
||
"
|
||
::= { ntp 7 }
|
||
|
||
ntpAddBclient OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set NTP peers to enable broadcast client mode.
|
||
|
||
This field has meaning only during 'write' operations.
|
||
"
|
||
::= { ntp 8 }
|
||
|
||
|
||
|
||
ntpDelPeer OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Delete NTP servers from the peer table.
|
||
|
||
This field has meaning only during 'write' operations.
|
||
"
|
||
::= { ntp 9 }
|
||
|
||
|
||
ntpClr OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clr (1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clear all the NTP peer addresses in the unit.
|
||
|
||
This field has meaning only during 'write' operations.
|
||
"
|
||
::= { ntp 10 }
|
||
|
||
|
||
ntpBTimer OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
t32 (32),
|
||
t64 (64),
|
||
t128 (128),
|
||
t256 (256),
|
||
t512 (512),
|
||
t1024 (1024)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports/Set the broadcast timer
|
||
t32 (32),
|
||
t64 (64),
|
||
t128 (128),
|
||
t256 (256),
|
||
t512 (512),
|
||
t1024 (1024)
|
||
"
|
||
::= { ntp 11 }
|
||
|
||
ntpPrefer OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
gps (1),
|
||
client (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the SSU time-of-day source from GPS or NTP Client.
|
||
"
|
||
::= { ntp 12 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 TIME
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- TOP LEVEL
|
||
tmCurTime OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current system time.
|
||
|
||
Note: user can change the system time only when the system is in LOCAL mode.
|
||
If the system is SERVER or NTP CLIENT, changing system time is not allowed.
|
||
"
|
||
::= { time 1 }
|
||
|
||
tmLocalOffset OBJECT-TYPE
|
||
SYNTAX TLocalTimeOffset
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set local time offset.
|
||
|
||
Note: This allow the users to set a local time offset.
|
||
The local time offset limits are (+/-)13 hours.
|
||
This is primarily used in systems with GPS or NTP time-of-day references.
|
||
where users' prefer system time to be set to local time.
|
||
"
|
||
::= { time 2 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 PQL TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- The DS1 PQL Table
|
||
-- ******************************************
|
||
|
||
pqlDs1Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PqlDs1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PQL entries.
|
||
The total entries are 16."
|
||
::= { pqlTable 1 }
|
||
|
||
pqlDs1Entry OBJECT-TYPE
|
||
SYNTAX PqlDs1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A PQL entry containing objects of each PQL."
|
||
INDEX { pqlDs1Index }
|
||
::= { pqlDs1Table 1 }
|
||
|
||
PqlDs1Entry ::=
|
||
SEQUENCE {
|
||
pqlDs1Index
|
||
INTEGER,
|
||
pqlDs1Ssm
|
||
TSsm,
|
||
pqlDs1Descr
|
||
DisplayString
|
||
}
|
||
|
||
pqlDs1Index OBJECT-TYPE
|
||
SYNTAX INTEGER (1..16)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A unique value for each PQL table.
|
||
This value ranges from 1 to 16."
|
||
::= { pqlDs1Entry 1 }
|
||
|
||
|
||
pqlDs1Ssm OBJECT-TYPE
|
||
SYNTAX TSsm
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This DS1 Sync Status Message (SSM) value for that Priority Quality Level (PQL) entry.
|
||
|
||
Note: If value of this entry is 0xff, the entry is not used.
|
||
This is the 8-bit value. If the 8th bit is set, this SSM value is not telcom standard.
|
||
Use caution when modifying as system characteristics will be altered.
|
||
"
|
||
::= { pqlDs1Entry 2 }
|
||
|
||
|
||
pqlDs1Descr OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report description for the DS1 Priority Quality Level (PQL) entry."
|
||
::= { pqlDs1Entry 3 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- The E1 PQL Table
|
||
-- ******************************************
|
||
|
||
pqlE1Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PqlE1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PQL entries.
|
||
The total entries are 16."
|
||
::= { pqlTable 2 }
|
||
|
||
pqlE1Entry OBJECT-TYPE
|
||
SYNTAX PqlE1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A PQL entry attributes.
|
||
pqlE1Index
|
||
Index value for each PQL table.
|
||
pqlE1Ssm
|
||
Report/Set the E1 Sync Status Message (SSM) value for that Priority Quality Level (PQL) entry.
|
||
pqlE1Descr
|
||
Report/Set description for the E1 Priority Quality Level (PQL) entry.
|
||
"
|
||
INDEX { pqlE1Index }
|
||
::= { pqlE1Table 1 }
|
||
|
||
PqlE1Entry ::=
|
||
SEQUENCE {
|
||
pqlE1Index
|
||
INTEGER,
|
||
pqlE1Ssm
|
||
TSsm,
|
||
pqlE1Descr
|
||
DisplayString
|
||
}
|
||
|
||
pqlE1Index OBJECT-TYPE
|
||
SYNTAX INTEGER (1..16)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index value for each PQL table.
|
||
This value ranges from 1 to 16."
|
||
::= { pqlE1Entry 1 }
|
||
|
||
|
||
pqlE1Ssm OBJECT-TYPE
|
||
SYNTAX TSsm
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the E1 Sync Status Message (SSM) value for that Priority Quality Level (PQL) entry.
|
||
|
||
Note: If value of this entry is 0xff, this entry is not used.
|
||
This is the 8-bits value. If the 8th bit is set, this SSM value is not telcom standard.
|
||
Use caution when modifying as system characteristics will be altered.
|
||
"
|
||
::= { pqlE1Entry 2 }
|
||
|
||
pqlE1Descr OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..14))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set description for the E1 Priority Quality Level (PQL) entry."
|
||
::= { pqlE1Entry 3 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- Reset PQL Table
|
||
-- ******************************************
|
||
|
||
pqlReset OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
factory(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set DS1/E1 Priority Quality Level(PQL) tables into factory defaults.
|
||
|
||
Note: It only has meaning for 'write' operations.
|
||
"
|
||
::= { pqlTable 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 IONAME TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
ionameTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF IonEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of input/output name entries.
|
||
"
|
||
::= { ioname 1 }
|
||
|
||
|
||
ionEntry OBJECT-TYPE
|
||
SYNTAX IonEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An io name entry attributes.
|
||
ionChassis
|
||
Identifies which chassis is being addressed.
|
||
ionSlot
|
||
Identifies which slot is being addressed.
|
||
ionPort
|
||
Identifies which port is being addressed.
|
||
ionName
|
||
Report/Set port ioname field.
|
||
"
|
||
INDEX { ionChassis, ionSlot, ionPort }
|
||
::= { ionameTable 1 }
|
||
|
||
IonEntry ::=
|
||
SEQUENCE {
|
||
ionChassis
|
||
INTEGER,
|
||
ionSlot
|
||
INTEGER,
|
||
ionPort
|
||
INTEGER,
|
||
ionName
|
||
DisplayString
|
||
}
|
||
|
||
ionChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { ionEntry 1 }
|
||
|
||
ionSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { ionEntry 2 }
|
||
|
||
|
||
ionPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis number, slot, and port number uniquely identify each inventory entry.
|
||
"
|
||
::= { ionEntry 3 }
|
||
|
||
ionName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set port ioname field.
|
||
If the name is a null string (zero length), this i/o name s cleared from the port.
|
||
"
|
||
::= { ionEntry 4 }
|
||
|
||
|
||
-- ******************************************
|
||
-- IONAME SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
ionameLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (3..20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The text string of the input/output port.
|
||
The format is defined as xAy-z or xAy-z&&z (if specified the range of ports)
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
- is the constant letter '-', and is slot/port sepearator
|
||
z is the port number (1 to 3, if input) or
|
||
(1 to 20, if output port).
|
||
&& is the two constant letters '&&', and is port range sepearator
|
||
z is the ending port number (1 to 3, if input) or
|
||
(1 to 20, if output port).
|
||
|
||
For example:
|
||
1A3-1 means this port located at chassis 1, slot 3, and port 1.
|
||
2A5-2&&5 means this ports located at chassis 2, slot 5, and ports 2 thru 5.
|
||
|
||
Note: the user must specify valid port address.
|
||
The valid port must be physically installed in the system.
|
||
"
|
||
::= { ioname 2 }
|
||
|
||
|
||
ionameSet OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set name associated input/output ports.
|
||
|
||
If the name is a null string, this i/o name is cleared from the ports.
|
||
|
||
Note: You must specify the i/o port range first, and then provide the i/o name.
|
||
"
|
||
::= { ioname 3 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 COMMUNICATION PORT (SUCH AS RS232) GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 RS232
|
||
-- **************************************************************
|
||
|
||
com232Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF ComEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of RS232 port entries. The total entries are 3."
|
||
::= { comm 1 }
|
||
|
||
|
||
comEntry OBJECT-TYPE
|
||
SYNTAX ComEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An RS232 communication entry attributes.
|
||
comIndex
|
||
Index for each communication table.
|
||
comMode
|
||
Set the specified RS232 port command parser to ICS or TL1.
|
||
comEcho
|
||
Enable/disable echo on the specified RS232 port.
|
||
comEol
|
||
Set the specified RS232 port End Of Line (EOL) terminator.
|
||
comBaud
|
||
Set the specified RS232 port baud rate.
|
||
"
|
||
INDEX { comIndex }
|
||
::= { com232Table 1 }
|
||
|
||
ComEntry ::=
|
||
SEQUENCE {
|
||
comIndex
|
||
INTEGER,
|
||
comMode
|
||
INTEGER,
|
||
comEcho
|
||
OnValue,
|
||
comEol
|
||
INTEGER,
|
||
comBaud
|
||
INTEGER
|
||
}
|
||
|
||
|
||
comIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each communication table.
|
||
This value ranges from 1 to 3."
|
||
::= { comEntry 1 }
|
||
|
||
|
||
comMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ics(1),
|
||
tl1(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the specified RS232 port command parser to ICS or TL1.
|
||
"
|
||
::= { comEntry 2 }
|
||
|
||
comEcho OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable echo on the specified RS232 port.
|
||
|
||
Note: This only affects the ICS command mode.
|
||
"
|
||
::= { comEntry 3 }
|
||
|
||
comEol OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
cr (1),
|
||
lf (2),
|
||
crlf (3)
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the specified RS232 port End Of Line (EOL) terminator.
|
||
cr (1),
|
||
lf (2),
|
||
crlf (3)
|
||
"
|
||
::= { comEntry 4 }
|
||
|
||
comBaud OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
baud1200 (1200),
|
||
baud2400 (2400),
|
||
baud4800 (4800),
|
||
baud9600 (9600),
|
||
baud19200 (19200)
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the specified RS232 port baud rate.
|
||
Valid baud rates are:
|
||
baud1200 (1200),
|
||
baud2400 (2400),
|
||
baud4800 (4800),
|
||
baud9600 (9600),
|
||
baud19200 (19200)
|
||
"
|
||
::= { comEntry 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 COMMUNICATION (INCLUDE TELNET AND ETHERNET TL1)
|
||
-- **************************************************************
|
||
|
||
comParmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF ComParmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of communication port setting entries (such as timeout).
|
||
The total entries are 5."
|
||
::= { comm 2 }
|
||
|
||
|
||
comParmEntry OBJECT-TYPE
|
||
SYNTAX ComParmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Communication setting entry for each logical port.
|
||
comParmIndex
|
||
Index for each communication parameter table.
|
||
comType
|
||
Specify the communication port.
|
||
comTimeout
|
||
Report/Set communication port session timeout (in seconds).
|
||
"
|
||
INDEX { comParmIndex }
|
||
::= { comParmTable 1 }
|
||
|
||
|
||
ComParmEntry ::=
|
||
SEQUENCE {
|
||
comParmIndex
|
||
INTEGER,
|
||
comType
|
||
INTEGER,
|
||
comTimeout
|
||
INTEGER
|
||
}
|
||
|
||
|
||
comParmIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each communication parameter table.
|
||
This value ranges from 1 to 5."
|
||
::= { comParmEntry 1 }
|
||
|
||
|
||
comType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
local (1),
|
||
coma (2),
|
||
comb (3),
|
||
telnet (4),
|
||
etl1 (5) -- Ethernet TL1
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Specify the communication port.
|
||
Valid values are:
|
||
1 = local (RS232)
|
||
2 = com A (RS232)
|
||
3 = com B (RS232)
|
||
4 = telnet
|
||
5 = telnet TL1 port
|
||
"
|
||
::= { comParmEntry 2 }
|
||
|
||
comTimeout OBJECT-TYPE
|
||
SYNTAX INTEGER (0| 5..43200)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set communication port session timeout (in seconds).
|
||
|
||
Note: 0 = NEVER timeout.
|
||
"
|
||
::= { comParmEntry 3 }
|
||
|
||
|
||
|
||
-- ******************************************
|
||
-- COM SCALER METHODS
|
||
-- ******************************************
|
||
|
||
comLogoff OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
local (1),
|
||
coma (2),
|
||
comb (3),
|
||
telneta (4),
|
||
telnetb (5),
|
||
telnetc (6),
|
||
telnetd (7),
|
||
etl1a (8),
|
||
etl1b (9),
|
||
etl1c (10),
|
||
etl1d (11)
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Logoff user on another logical communication port.
|
||
|
||
The valid communication port are:
|
||
local (1),
|
||
coma (2),
|
||
comb (3),
|
||
telneta (4),
|
||
telnetb (5),
|
||
telnetc (6),
|
||
telnetd (7),
|
||
etl1a (8),
|
||
etl1b (9),
|
||
etl1c (10),
|
||
etl1d (11)
|
||
|
||
Note: This field only has meaning for 'write' operations.
|
||
"
|
||
::= { comm 3 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 SNMPv2 MANAGER TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
snmpv2manTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Snmpv2manEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the SNMPv2 manager(s) IP address.
|
||
"
|
||
::= { snmpman 1 }
|
||
|
||
snmpv2manEntry OBJECT-TYPE
|
||
SYNTAX Snmpv2manEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv2 manager table attributes.
|
||
snmpv2manIndex
|
||
Index for each SNMPv2 manager table entry.
|
||
snmpv2manIp
|
||
Set the snmpv2 manager IP address.
|
||
"
|
||
INDEX { snmpv2manIndex }
|
||
::= { snmpv2manTable 1 }
|
||
|
||
Snmpv2manEntry ::=
|
||
SEQUENCE {
|
||
snmpv2manIndex
|
||
INTEGER,
|
||
snmpv2manIp
|
||
IpAddress
|
||
}
|
||
|
||
snmpv2manIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each SNMPv2 manager table entry.
|
||
This value range from 1 to 4."
|
||
::= { snmpv2manEntry 1 }
|
||
|
||
snmpv2manIp OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the snmpv2 manager IP address.
|
||
Write a new IP address will put this new IP into table.
|
||
Write zero IP address will delete this IP address from table.
|
||
Note: The above only apply to SNMPv2.
|
||
"
|
||
::= { snmpv2manEntry 2 }
|
||
|
||
|
||
-- ******************************************
|
||
-- SNMP SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
snmpmanInit OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
initv2 (1), -- initialize the SNMPv2 manager table
|
||
initv3 (2) -- initialize the SNMPv3 manager table
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Initializes the SNMP Manager Table to null IP addresses.
|
||
Note: This field only has meaning when 'write' operations
|
||
"
|
||
::= { snmpman 2 }
|
||
|
||
|
||
snmpmanTrap OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
alarm(1),
|
||
all(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the SNMP trap filter to SNMP Manager.
|
||
The trap filter can be set to be 'alarm' only or all traps.
|
||
|
||
1 = alarm
|
||
2 = all
|
||
|
||
If 'alarm' trap, only events with ID less than 32 (i.e. alarms)
|
||
will be sent to the SNMP Manager. All other traps will be filtered
|
||
out. The purpose of this command is to reduce the traffic, if
|
||
desired.
|
||
"
|
||
::= { snmpman 3 }
|
||
|
||
|
||
snmpNotification OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
v2 (1), -- traps in v2 form, address from v2 manager table
|
||
v3 (2), -- traps in v3 form, address from v2 manager table
|
||
all(3) -- traps in v2/v3, address from v2/v3 table accordingly
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set SNMPv3 traps format to use.
|
||
v2 (1), -- traps in v2 form, address from v2 manager table
|
||
v3 (2), -- traps in v3 form, address from v2 manager table
|
||
all(3) -- traps in v2/v3, address from v2/v3 table accordingly
|
||
It can V2, V3, or both forms. Each v2/v3 traps sent out are viaits own manager table accordingly.
|
||
Note: The above only apply to SNMPv3 load.
|
||
"
|
||
::= { snmpman 4 }
|
||
|
||
snmpEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
v2enable(1), -- activate SNMPv2
|
||
v2disable(2) -- deactivate SNMPv2
|
||
}
|
||
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Activate/deactivate SNMPv2.
|
||
Note: The above only apply to SNMPv3 load.
|
||
"
|
||
::= { snmpman 5 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 SNMPv2 User TABLE GROUP
|
||
-- **************************************************************
|
||
|
||
snmpv2userTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Snmpv2userEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv2 User Table.
|
||
"
|
||
::= { snmpman 6 }
|
||
|
||
snmpv2userEntry OBJECT-TYPE
|
||
SYNTAX Snmpv2userEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv2 user table entry attributes.
|
||
snmpv2userIndex
|
||
Index for each SNMPv2 user table entry.
|
||
snmpv2user
|
||
Reports SNMPv2 user
|
||
"
|
||
INDEX { snmpv2userIndex }
|
||
::= { snmpv2userTable 1 }
|
||
|
||
Snmpv2userEntry ::=
|
||
SEQUENCE {
|
||
snmpv2userIndex
|
||
INTEGER,
|
||
snmpv2user
|
||
DisplayString
|
||
}
|
||
|
||
snmpv2userIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..6)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each SNMPv2 user entry.
|
||
"
|
||
::= { snmpv2userEntry 1 }
|
||
|
||
snmpv2user OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SNMPv2 user entry
|
||
It is the read community string of an SNMPv2 user
|
||
"
|
||
::= { snmpv2userEntry 2 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 SNMPv3 User TABLE GROUP
|
||
-- **************************************************************
|
||
|
||
snmpv3userTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Snmpv3userEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv3 User Table.
|
||
"
|
||
::= { snmpman 7 }
|
||
|
||
snmpv3userEntry OBJECT-TYPE
|
||
SYNTAX Snmpv3userEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv3 user table entry attributes.
|
||
snmpv3userIndex
|
||
Index for each SNMPv3 user table entry.
|
||
snmpv3user
|
||
Reports SNMPv3 user
|
||
"
|
||
INDEX { snmpv3userIndex }
|
||
::= { snmpv3userTable 1 }
|
||
|
||
Snmpv3userEntry ::=
|
||
SEQUENCE {
|
||
snmpv3userIndex
|
||
INTEGER,
|
||
snmpv3user
|
||
DisplayString
|
||
}
|
||
|
||
snmpv3userIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..6)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each SNMPv3 user table entry.
|
||
"
|
||
::= { snmpv3userEntry 1 }
|
||
|
||
snmpv3user OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SNMPv3 user
|
||
"
|
||
::= { snmpv3userEntry 2 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 SNMPv3 MANAGER TABLE GROUP
|
||
-- **************************************************************
|
||
|
||
snmpv3manTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Snmpv3manEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SNMPv3 manager IP address.
|
||
"
|
||
::= { snmpman 8 }
|
||
|
||
snmpv3manEntry OBJECT-TYPE
|
||
SYNTAX Snmpv3manEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SNMPv3 manager entry attributes.
|
||
snmpv3manIndex
|
||
Index for each SNMPv3 manager entry.
|
||
snmpv3manIp
|
||
Report/Set snmpv3 manager IP address.
|
||
snmpv3manUser
|
||
Report/Set the SNMPv3 user
|
||
"
|
||
INDEX { snmpv3manIndex }
|
||
::= { snmpv3manTable 1 }
|
||
|
||
Snmpv3manEntry ::=
|
||
SEQUENCE {
|
||
snmpv3manIndex
|
||
INTEGER,
|
||
snmpv3manIp
|
||
IpAddress,
|
||
snmpv3manUser
|
||
DisplayString
|
||
}
|
||
|
||
snmpv3manIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for each SNMPv3 manager entry.
|
||
This value range from 1 to 4."
|
||
::= { snmpv3manEntry 1 }
|
||
|
||
snmpv3manIp OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set snmpv3 manager IP address.
|
||
|
||
Note: No action shall be taken at this time.
|
||
Action shall be taken when the next field 'snmpv3manUser'is written.
|
||
The above only apply to SNMPv3.
|
||
"
|
||
::= { snmpv3manEntry 2 }
|
||
|
||
snmpv3manUser OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the SNMPv3 user
|
||
|
||
Note1: All user names are uppercase except the built-in user.
|
||
Write username will put this user along with ip into table.
|
||
Writing a null string will delete this entry from table.
|
||
Any previouly written IP has no meaning (i.e. the writing the null
|
||
string of username shall trigger the delete action of that entry from table.
|
||
Note2: There is no modify action. User need to delete an entry and then add an new entry.
|
||
Note3: The above only apply to SNMPv3.
|
||
"
|
||
::= { snmpv3manEntry 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 SYSTEM TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
sysPbo OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
event(1),
|
||
report(2),
|
||
none(3),
|
||
disable(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The input port Phase Built-Out ode (PBO).
|
||
1 = EVENT : PBO enabled, PBO sent out, and stored
|
||
in the event buffer.
|
||
2 = REPORT : PBO enabled, PBO sent out, but not stored
|
||
in the event buffer.
|
||
3 = NONE : PBO enabled, but PBO event not sent out.
|
||
4 = DISABLE : PBO disabled.
|
||
|
||
Note: This is a system-wide command.
|
||
When the user writes this field, it will affect all DS1/E1 input modules in the system.
|
||
"
|
||
::= { sys 1 }
|
||
|
||
sysResetClk OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reset the specified clock.
|
||
Restarts clock without maintaining current servo control values.
|
||
"
|
||
::= { sys 2 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 KEEPALIVE TABLE
|
||
-- **************************************************************
|
||
|
||
sysKeepAliveTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SysAliveEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set system 'keep alive' mode
|
||
where a trap is generated automatically on a period specified by the customer
|
||
This is intended to verify the upstream support that the SSU2000 and the associated communication path is functional"
|
||
::= { sys 3 }
|
||
|
||
|
||
sysAliveEntry OBJECT-TYPE
|
||
SYNTAX SysAliveEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"System 'keepalive' attributes for TL1 or SNMP.
|
||
sysAliveIndex
|
||
Index value for each 'keepalive' table.
|
||
sysAliveType
|
||
Keep Alive session type:
|
||
sysAliveTime
|
||
Keep alive message interval.
|
||
"
|
||
INDEX { sysAliveIndex }
|
||
::= { sysKeepAliveTable 1 }
|
||
|
||
|
||
SysAliveEntry ::=
|
||
SEQUENCE {
|
||
sysAliveIndex
|
||
INTEGER,
|
||
sysAliveType
|
||
INTEGER,
|
||
sysAliveTime
|
||
INTEGER
|
||
}
|
||
|
||
sysAliveIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index value for each 'keepalive' table.
|
||
This range of the value is from 1 to 2."
|
||
::= { sysAliveEntry 1 }
|
||
|
||
|
||
sysAliveType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
tl1(1),
|
||
snmp(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Keep Alive session type:
|
||
1 = TL1 session
|
||
2 = SNMP session
|
||
"
|
||
::= { sysAliveEntry 2 }
|
||
|
||
|
||
sysAliveTime OBJECT-TYPE
|
||
SYNTAX INTEGER (0..60)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Keep alive message interval.
|
||
Valid range = 1 - 60 (minutes).
|
||
0 = disabled (default)
|
||
"
|
||
::= { sysAliveEntry 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- Unit Operating Mode
|
||
-- **************************************************************
|
||
|
||
sysOpmode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
normal(1), -- Non-Subtending
|
||
subtending(2), -- Domestic Subtending
|
||
japanese(3) -- Japanese Subtending
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the operational mode in the SSU-2000.
|
||
normal(1), -- Non-Subtending
|
||
subtending(2), -- Domestic Subtending
|
||
japanese(3) -- Japanese Subtending
|
||
"
|
||
::= { sys 4 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- TL1 format
|
||
-- **************************************************************
|
||
|
||
sysTl1Format OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
gr831(1),
|
||
gr833(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the TL1 format in the SSU-2000.
|
||
Allows the system to generate GR-831 compliant or GR-833 compliant autonomous events.
|
||
All SSU-2000 TL1 sessions will generate either GR-831 or GR-833 autonomous events.
|
||
Refer to TL1 Specification 12613127-001-2 for event formats
|
||
"
|
||
::= { sys 5 }
|
||
|
||
-- **************************************************************
|
||
-- LOGIN/ LOGOUT EVENT
|
||
-- **************************************************************
|
||
|
||
sysEvtLogin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(1), -- not store login and logout in the event log
|
||
enable(2) -- store login and logout in the event log
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set LOGIN and LOGOUT events from being stored in the event log.
|
||
|
||
disable(1), -- not store login and logout in the event log
|
||
enable(2) -- store login and logout in the event log
|
||
"
|
||
::= { sys 6 }
|
||
|
||
-- **************************************************************
|
||
-- Alarm Cut Off (ACO)
|
||
-- **************************************************************
|
||
|
||
sysAco OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1), -- ACO active
|
||
inactive(2) -- ACO inactive
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set ACO when writing with active.
|
||
It has NOP when write with inactive.
|
||
When read, it returns the current state of ACO.
|
||
"
|
||
::= { sys 7 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 USERS TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
userTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF UserEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report valid user names and their associated user access level.
|
||
This user list is used for connecting the ICS and TL1 command parser via RS232 or Ethernet port (telnet or TL1 port).
|
||
Note: the password is not reported.
|
||
"
|
||
::= { users 1 }
|
||
|
||
userEntry OBJECT-TYPE
|
||
SYNTAX UserEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User table attributes:
|
||
userIndex
|
||
Index for each user entry.
|
||
userlevel
|
||
Reports user access level.
|
||
username
|
||
Reports user name.
|
||
"
|
||
INDEX { userIndex }
|
||
::= { userTable 1 }
|
||
|
||
|
||
UserEntry ::=
|
||
SEQUENCE {
|
||
userIndex
|
||
INTEGER,
|
||
userlevel
|
||
INTEGER,
|
||
username
|
||
DisplayString
|
||
}
|
||
|
||
userIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..25)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports index for each user entry.
|
||
This value ranges from 1 to 25.
|
||
"
|
||
::= { userEntry 1 }
|
||
|
||
|
||
userlevel OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports user access level.
|
||
The user level:
|
||
(1) USER - Read Only - can retrieve status information only.
|
||
(2) TECHNICIAN - Read and limited set ability for fault isolating and installation setup of the unit.
|
||
(3) SUPERVISORY - For configuration modifications.
|
||
(4) ADMINISTRATOR - Setup or change user access.
|
||
"
|
||
::= { userEntry 2 }
|
||
|
||
|
||
username OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports user name."
|
||
::= { userEntry 3 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 WHO TABLE GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
whoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WhoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which users are logged into all active communication ports (RS232, TL1, or telnet).
|
||
It displays the username and the communication port.
|
||
"
|
||
::= { who 1 }
|
||
|
||
whoEntry OBJECT-TYPE
|
||
SYNTAX WhoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report 'who' table attributes.
|
||
whoIndex
|
||
Report index of the 'who' entry.
|
||
whoPort
|
||
Report logical communication port.
|
||
whoName
|
||
Report user name.
|
||
"
|
||
INDEX { whoIndex }
|
||
::= { whoTable 1 }
|
||
|
||
WhoEntry ::=
|
||
SEQUENCE {
|
||
whoIndex
|
||
INTEGER,
|
||
whoPort
|
||
INTEGER,
|
||
whoName
|
||
DisplayString
|
||
}
|
||
|
||
whoIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..12)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report index of the 'who' entry.
|
||
This value ranges from 1 to 11."
|
||
::= { whoEntry 1 }
|
||
|
||
whoPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
local(1),
|
||
coma(2),
|
||
comb(3),
|
||
telneta(4),
|
||
telnetb(5),
|
||
telnetc(6),
|
||
telnetd(7),
|
||
etl1a(8),
|
||
etl1b(9),
|
||
etl1c(10),
|
||
etl1d(11)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report logical communication port.
|
||
local(1), -- serial local (craft) port
|
||
coma(2), -- serial port A
|
||
comb(3), -- serial port B
|
||
telneta(4), -- telnet session A
|
||
telnetb(5), -- telnet session B
|
||
telnetc(6), -- telnet session C
|
||
telnetd(7), -- telnet session D
|
||
etl1a(8), -- TL1 session A
|
||
etl1b(9), -- TL1 session B
|
||
etl1c(10), -- TL1 session C
|
||
etl1d(11) -- TL1 session D
|
||
"
|
||
::= { whoEntry 2 }
|
||
|
||
|
||
whoName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report user name."
|
||
::= { whoEntry 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 NTPQ GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
ntpqXeq OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report/Set the PackeTime Module.
|
||
The format is defined as xAy.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
|
||
For example: 1A6 means this PackeTime located at chassis 1, slot 6
|
||
|
||
Note: the user must specify valid PackeTime address.
|
||
The valid module must be physically installed in the system.
|
||
Note: Writing operation causes the system to execute the ntpq.
|
||
The ntpq returned value may take 2 seconds.
|
||
"
|
||
::= { ntpq 1 }
|
||
|
||
ntpqSyspeer OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report syspeer is the IP address of peer selected by server as most likely to provide best timing information.
|
||
"
|
||
::= { ntpq 4 }
|
||
|
||
ntpqSysleap OBJECT-TYPE
|
||
SYNTAX INTEGER (-1..2)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report system leap indicator
|
||
The NTP server leap indicator (0, +1, -1, or NOSYNC).
|
||
2 = NOSYNC
|
||
"
|
||
::= { ntpq 5 }
|
||
|
||
ntpqSysstratum OBJECT-TYPE
|
||
SYNTAX INTEGER (0..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report system NTP server stratum level
|
||
"
|
||
::= { ntpq 6 }
|
||
|
||
ntpqSysprecision OBJECT-TYPE
|
||
SYNTAX INTEGER (-100..0)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report measurement of a number of significant bits in NTP timestamp
|
||
"
|
||
::= { ntpq 7 }
|
||
|
||
ntpqRootdelay OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report calculated root delay value to primary source
|
||
"
|
||
::= { ntpq 8 }
|
||
|
||
ntpqRootdispersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report NTP system Root Dispersion (max error relative to the primary
|
||
reference source at the root of the synchronization subnet, in seconds)
|
||
"
|
||
::= { ntpq 9 }
|
||
|
||
ntpqSysoffset OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report clients calculated time offset value for the specified server
|
||
"
|
||
::= { ntpq 10 }
|
||
|
||
ntpqReftime OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..60))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report local reference time
|
||
"
|
||
::= { ntpq 11 }
|
||
|
||
-- ******************************************
|
||
-- NTPQ TABLE
|
||
-- ******************************************
|
||
|
||
ntpqTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF NtpqEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime NTPQ entries.
|
||
"
|
||
::= { ntpq 3 }
|
||
|
||
ntpqEntry OBJECT-TYPE
|
||
SYNTAX NtpqEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report NTPQ attributes.
|
||
ntpqChassis
|
||
Identifies which chassis is being addressed.
|
||
ntpqSlot
|
||
Identifies which slot is being addressed.
|
||
ntpqIndex
|
||
Identifies which index is being addressed.
|
||
ntpqValid
|
||
Reports validity of entry.
|
||
ntpqPeer
|
||
Reports address of NTP peer
|
||
ntpqRefid
|
||
Reports NTP peer reference ID
|
||
ntpqStratum
|
||
Reports NTP peer stratum level
|
||
ntpqPoll
|
||
Reports NTP peer poll interval
|
||
ntpqReach
|
||
Reports NTP peer reachability
|
||
ntpqDelay
|
||
Reports NTP peer delay
|
||
ntpqOffset
|
||
Reports NTP peer offset
|
||
ntpqJitter
|
||
Report NTP peer jitter
|
||
"
|
||
INDEX { ntpqChassis, ntpqSlot, ntpqIndex }
|
||
::= { ntpqTable 1 }
|
||
|
||
NtpqEntry ::=
|
||
SEQUENCE {
|
||
ntpqChassis
|
||
INTEGER,
|
||
ntpqSlot
|
||
INTEGER,
|
||
ntpqIndex
|
||
INTEGER,
|
||
ntpqValid
|
||
ValidValue,
|
||
ntpqPeer
|
||
DisplayString,
|
||
ntpqRefid
|
||
DisplayString,
|
||
ntpqStratum
|
||
INTEGER,
|
||
ntpqPoll
|
||
INTEGER,
|
||
ntpqReach
|
||
DisplayString,
|
||
ntpqDelay
|
||
DisplayString,
|
||
ntpqOffset
|
||
DisplayString,
|
||
ntpqJitter
|
||
DisplayString
|
||
}
|
||
|
||
ntpqChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { ntpqEntry 1 }
|
||
|
||
ntpqSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { ntpqEntry 2 }
|
||
|
||
ntpqIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..9)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which index is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { ntpqEntry 3 }
|
||
|
||
ntpqValid OBJECT-TYPE
|
||
SYNTAX ValidValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports validity of entry.
|
||
If this entry is not valid, all info in this entry has no meaning.
|
||
"
|
||
::= { ntpqEntry 4 }
|
||
|
||
ntpqPeer OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports address of NTP peer
|
||
"
|
||
::= { ntpqEntry 5 }
|
||
|
||
ntpqRefid OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports NTP system Reference
|
||
"
|
||
::= { ntpqEntry 6 }
|
||
|
||
ntpqStratum OBJECT-TYPE
|
||
SYNTAX INTEGER (0..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports NTP server stratum level
|
||
"
|
||
::= { ntpqEntry 7 }
|
||
|
||
ntpqPoll OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1024)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports NTP server poll interval
|
||
"
|
||
::= { ntpqEntry 8 }
|
||
|
||
ntpqReach OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports NTP server reachability
|
||
"
|
||
::= { ntpqEntry 9 }
|
||
|
||
ntpqDelay OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports calculated root delay value to primary source
|
||
"
|
||
::= { ntpqEntry 10 }
|
||
|
||
ntpqOffset OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports client's calculated time offset value for the specified server
|
||
"
|
||
::= { ntpqEntry 11 }
|
||
|
||
ntpqJitter OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report jitter value
|
||
"
|
||
::= { ntpqEntry 12 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 STATIC ROUTE STATUS GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS
|
||
-- ******************************************
|
||
|
||
rtXeq OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Write access level: level 1 or above
|
||
|
||
The text string of the PackeTime Module.
|
||
The format is defined as xAy.
|
||
where
|
||
x is the chassis number: in this case is 1,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 3 to 11)
|
||
|
||
For example: 1A6 means this PackeTime located at
|
||
chassis 1, slot 6
|
||
|
||
Note1: the user must specify valid PackeTime address.
|
||
The valid module must be physically installed in the system.
|
||
Note2: Writing operation causes the system to execute the route table.
|
||
The route table returned value may take 2 seconds.
|
||
"
|
||
::= { route 1 }
|
||
|
||
-- ******************************************
|
||
-- ROUTE TABLE
|
||
-- ******************************************
|
||
|
||
routeTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF RouteEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime route entries.
|
||
"
|
||
::= { route 3 }
|
||
|
||
rtEntry OBJECT-TYPE
|
||
SYNTAX RouteEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime route table attributes:
|
||
rtChassis
|
||
Identifies which chassis is being addressed.
|
||
rtSlot
|
||
Identifies which slot is being addressed.
|
||
rtIndex
|
||
Identifies which index is being addressed.
|
||
rtValid
|
||
Reports validity of entry.
|
||
rtDest
|
||
Reports destination network/host
|
||
rtGate
|
||
Reports destination gateway
|
||
rtMask
|
||
Reports destination network mask
|
||
rtFlags
|
||
Reports route flags
|
||
rtMetric
|
||
Reports the 'distance' to the target (router hops).
|
||
rtRef
|
||
Reports number of references to this route.
|
||
rtUse
|
||
Report number of lookups for the route.
|
||
rtIface
|
||
Report interface associated with this route.
|
||
"
|
||
INDEX { rtChassis, rtSlot, rtIndex }
|
||
::= { routeTable 1 }
|
||
|
||
RouteEntry ::=
|
||
SEQUENCE {
|
||
rtChassis
|
||
INTEGER,
|
||
rtSlot
|
||
INTEGER,
|
||
rtIndex
|
||
INTEGER,
|
||
rtValid
|
||
ValidValue,
|
||
rtDest
|
||
IpAddress,
|
||
rtGate
|
||
IpAddress,
|
||
rtMask
|
||
IpAddress,
|
||
rtFlags
|
||
DisplayString,
|
||
rtMetric
|
||
INTEGER,
|
||
rtRef
|
||
INTEGER,
|
||
rtUse
|
||
INTEGER,
|
||
rtIface
|
||
INTEGER
|
||
}
|
||
|
||
rtChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { rtEntry 1 }
|
||
|
||
rtSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { rtEntry 2 }
|
||
|
||
rtIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which index is being addressed.
|
||
This chassis, slot, and index number uniquely identify each entry.
|
||
"
|
||
::= { rtEntry 3 }
|
||
|
||
rtValid OBJECT-TYPE
|
||
SYNTAX ValidValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports validity of entry.
|
||
If this entry is not valid, all info in this entry has no meaning.
|
||
"
|
||
::= { rtEntry 4 }
|
||
|
||
rtDest OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports destination network/host
|
||
or 0.0.0.0 is default.
|
||
"
|
||
::= { rtEntry 5 }
|
||
|
||
rtGate OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports gateway address
|
||
or 0.0.0.0 if none set
|
||
"
|
||
::= { rtEntry 6 }
|
||
|
||
rtMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports netmask for the destination net;
|
||
'255.255.255.255' for a host destination and '0.0.0.0' for the default route.
|
||
"
|
||
::= { rtEntry 7 }
|
||
|
||
rtFlags OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" Reports route table flags
|
||
U (route is up)
|
||
H (target is a host)
|
||
G (use gateway)
|
||
R (reinstate route for dynamic routing)
|
||
D (dynamically installed by daemon or redirect)
|
||
M (modified from routing daemon or redirect)
|
||
A (installed by addrconf)
|
||
C (cache entry)
|
||
! (reject route)
|
||
"
|
||
::= { rtEntry 8 }
|
||
|
||
rtMetric OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the 'distance' to the target (router hops).
|
||
"
|
||
::= { rtEntry 9 }
|
||
|
||
rtRef OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports number of references to this route.
|
||
"
|
||
::= { rtEntry 10 }
|
||
|
||
rtUse OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report number of lookups for the route.
|
||
"
|
||
::= { rtEntry 11 }
|
||
|
||
rtIface OBJECT-TYPE
|
||
SYNTAX INTEGER (0..34094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Report interface associated with this route.
|
||
0 = eth0 (Maintenance Port)
|
||
1 = eth1 (Service Port A)
|
||
2 = eth2 (Service Port B)
|
||
3 = bond0 (Service Port Bonding)
|
||
10000-14094 = eth1.xxxx
|
||
20000-24094 = eth2.xxxx
|
||
30000-34094 = bond0.xxxx
|
||
where xxxx is the VLAN ID.
|
||
"
|
||
::= { rtEntry 12 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 TRAP REQUEST GROUP
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
tprTag OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This command is to ask the agent to resend a lost trap.
|
||
The lost trap is specified by its trap tag number.
|
||
The trap tag number is a 32-bit positive integer. It will
|
||
rollover to one, when it reaches the maximum number
|
||
2147483647.
|
||
|
||
If the tag number is beyond the agent's abilities to handle,
|
||
it will respond with an error. Otherwise, the requested trap
|
||
will be sent to the manager.
|
||
|
||
Note: When resending a trap, the 'tpEvt' field of trap is set
|
||
to 2 (RE-SEND). In the normal trap, the'tpEvt' field of trap
|
||
is set to 1 (AUTONOMOUS).
|
||
"
|
||
::= { mTrapReq 1 }
|
||
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 TRAP OBJECTS
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
tpTag OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap counter which increments for each trap.
|
||
"
|
||
::= { mTrapObjs 1 }
|
||
|
||
tpEvt OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
autonomous(1),
|
||
resend(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indication of whether trap is an autonomous event or resend by user request.
|
||
"
|
||
::= { mTrapObjs 2 }
|
||
|
||
tpId OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap ID number."
|
||
::= { mTrapObjs 3 }
|
||
|
||
tpMCode OBJECT-TYPE
|
||
SYNTAX TModuleCode
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap module hex code (16-bits)."
|
||
::= { mTrapObjs 4 }
|
||
|
||
tpTimestamp OBJECT-TYPE
|
||
SYNTAX DateAndTime
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This DateAndTime string contains the event timestamp."
|
||
::= { mTrapObjs 5 }
|
||
|
||
tpChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap chassis number.
|
||
In SSU2000, there are some modules have to inserted in the main chassis:
|
||
COMM, CLOCK, INPUT, GPS modules.
|
||
"
|
||
::= { mTrapObjs 6 }
|
||
|
||
tpSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap slot number.
|
||
In SSU2000, there are some modules have to inserted in the fixed locations:
|
||
COMM - 1A2
|
||
CLOCK - 1A1 or 1A17 (physical slot address)
|
||
GPS - 1A3 or 1A5.
|
||
"
|
||
::= { mTrapObjs 7 }
|
||
|
||
tpPort OBJECT-TYPE
|
||
SYNTAX INTEGER (0..20)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap port number.
|
||
If value 0, it means (DON'T CARE) whole module.
|
||
In SSU2000, most of the DS1/E1 input module alarms specify the port number (1-3).
|
||
The remaining modules specify the port number as either '0' or '1'.
|
||
"
|
||
::= { mTrapObjs 8 }
|
||
|
||
|
||
tpAlmCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
ignore(4),
|
||
report(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap alarm code.
|
||
|
||
Relationship between tpAlmCode and tpNtfCode.
|
||
For example:
|
||
If for the set MINOR alarm, the tpAlmCode is MINOR and the tpNtfCode is MINOR.
|
||
If the MINIR alarm is cleared, the tpAlmCode is MINOR and the tpNtfCode is CLEAR.
|
||
|
||
For all events:
|
||
The tpAlmCode and tpNtfCode are REPORT.
|
||
"
|
||
::= { mTrapObjs 9 }
|
||
|
||
tpNtfCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
minor(1),
|
||
major(2),
|
||
critical(3),
|
||
report(5),
|
||
clear(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The trap alarm notification code.
|
||
|
||
Relationship between tpAlmCode and tpNtfCode.
|
||
For example for alarms:
|
||
If for the set MINOR alarm, the tpAlmCode is MINOR and the tpNtfCode is MINOR.
|
||
If the MINOR alarm is cleared, the tpAlmCode is MINOR and the tpNtfCode is CLEAR.
|
||
|
||
For all events:
|
||
The tpAlmCode and tpNtfCode are REPORT.
|
||
"
|
||
::= { mTrapObjs 10 }
|
||
|
||
tpElevated OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
yes(1),
|
||
no(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This alarm if elevated."
|
||
::= { mTrapObjs 11 }
|
||
|
||
tpDescr OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The text string description of the event.
|
||
"
|
||
::= { mTrapObjs 12 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 TRAP NOTIFICATION OBJECTS
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
ssuTraps OBJECT-IDENTITY
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The SSU2000 traps"
|
||
::= {mTraps 0}
|
||
|
||
|
||
ssuEvent NOTIFICATION-TYPE
|
||
OBJECTS {tpTag, tpEvt, tpId, tpMCode,tpTimestamp,
|
||
tpChassis, tpSlot, tpPort,
|
||
tpAlmCode, tpNtfCode, tpElevated, tpDescr}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SSU2000 trap object which specifies trap tag number, trap id number, module hex code, timestamp, chassis number,
|
||
slot number, port number, alarm code, alarm notification code, and the text string description.
|
||
"
|
||
::= {ssuTraps 1}
|
||
|
||
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
-- SSU2000 INTERFACES OBJECTS
|
||
-- Note: Developer could use following objects to determine the
|
||
-- SSU2000 resources in the unit right away.
|
||
-- **************************************************************
|
||
-- **************************************************************
|
||
|
||
sifNtpNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no NTP resource present
|
||
1 = if NTP presentt
|
||
"
|
||
::= { sInterfaces 1 }
|
||
|
||
sifSnmpv2Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no SNMPv2 resource present (note: it is load resource, not enable/disable)
|
||
1 = if SNMPv2 present
|
||
"
|
||
::= { sInterfaces 2 }
|
||
|
||
sifSnmpv3Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no SNMPv3 resource present (note: it is load resource, not enable/disable)
|
||
1 = if SNMPv3 present
|
||
"
|
||
::= { sInterfaces 3 }
|
||
|
||
sifClkNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..2)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no Clock Module present
|
||
x = number of Clock Modules present
|
||
"
|
||
::= { sInterfaces 10 }
|
||
|
||
sifGpsNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..2)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no GPS Module present
|
||
x = number of GPS Modules present
|
||
"
|
||
::= { sInterfaces 11 }
|
||
|
||
sifInpDs1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no DS1 Input Module present
|
||
x = number of DS1 Input Modules present
|
||
"
|
||
::= { sInterfaces 12 }
|
||
|
||
sifInpE1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no E1 Input Module present
|
||
x = number of E1 Input Modules present
|
||
"
|
||
::= { sInterfaces 13 }
|
||
|
||
sifInpCcNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no ANSI CC Input Module present
|
||
x = number of ANSI CC Input Modules present
|
||
"
|
||
::= { sInterfaces 14 }
|
||
|
||
sifOutDs1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no DS1 Output Module present
|
||
x = number of DS1 Output Modules present
|
||
"
|
||
::= { sInterfaces 15 }
|
||
|
||
sifOutE1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no E1 Output Module present
|
||
x = number of E1 Output Modules present
|
||
"
|
||
::= { sInterfaces 16 }
|
||
|
||
sifOut2048Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no 2048 Output Module present
|
||
x = number of 2048 Output Modules present
|
||
"
|
||
::= { sInterfaces 17 }
|
||
|
||
sifOutCcNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no ANSI CC Output Module present
|
||
x = number of ANSI CC Output Modules present
|
||
"
|
||
::= { sInterfaces 18 }
|
||
|
||
|
||
sifOutE12048Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no E1/2048KHZ Output Module present
|
||
x = number of E1/2048KHZ Output Modules present
|
||
"
|
||
::= { sInterfaces 19 }
|
||
|
||
sifOut422Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no RS422 Output Module present
|
||
x = number of RS422 Output Modules present
|
||
"
|
||
::= { sInterfaces 20 }
|
||
|
||
sifLrmDs1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no DS1 LRM Module present
|
||
x = number of DS1 LRM Modules present
|
||
"
|
||
::= { sInterfaces 21 }
|
||
|
||
|
||
sifOutJsineNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no Japanese Sine (J/SW) Output Module present
|
||
x = number of Sine (J/SW) Output Modules present
|
||
"
|
||
::= { sInterfaces 22 }
|
||
|
||
sifInpJsineNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no Japanese Sine (J/SW) Input Module present
|
||
x = number of Sine (J/SW) Input Modules present
|
||
"
|
||
::= { sInterfaces 23 }
|
||
|
||
sifOutJccNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no Japanese CC (J/CC) Output Module present
|
||
x = number of Japanese CC (J/CC) Output Modules present
|
||
"
|
||
::= { sInterfaces 24 }
|
||
|
||
sifInpJccNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no Japanese CC (J/CC) Input Module present
|
||
x = number of Japanese CC (J/CC) Input Modules present
|
||
"
|
||
::= { sInterfaces 25 }
|
||
|
||
sifLrmE1Number OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"0 = if no E1 LRM Module present
|
||
x = number of E1 LRM Modules present
|
||
"
|
||
::= { sInterfaces 26 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 PACKETIME PTP MODULE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staPtPtpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaPtPtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of PackeTime PTP status information.
|
||
"
|
||
::= { statusPtPtp 1 }
|
||
|
||
|
||
staPtPtpEntry OBJECT-TYPE
|
||
SYNTAX StaPtPtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The entries of PackeTime PTP status attributes.
|
||
"
|
||
INDEX { staPtPtpChassis, staPtPtpSlot}
|
||
::= { staPtPtpTable 1 }
|
||
|
||
StaPtPtpEntry ::=
|
||
SEQUENCE {
|
||
staPtPtpChassis
|
||
INTEGER,
|
||
staPtPtpSlot
|
||
INTEGER,
|
||
staPtPtpStatus
|
||
INTEGER,
|
||
staPtPtpClkSel
|
||
INTEGER,
|
||
staPtPtpClka
|
||
ActiveValue,
|
||
staPtPtpClkb
|
||
ActiveValue,
|
||
staPtPtpClkc
|
||
ActiveValue,
|
||
staPtPtpClkd
|
||
ActiveValue,
|
||
staPtPtpRednt
|
||
INTEGER,
|
||
staPtPtpModState
|
||
INTEGER,
|
||
staPtPtpPAState
|
||
INTEGER,
|
||
staPtPtpTod
|
||
OnValue,
|
||
staPtPtpCommit
|
||
INTEGER
|
||
}
|
||
|
||
staPtPtpChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staPtPtpEntry 1 }
|
||
|
||
staPtPtpSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staPtPtpEntry 2 }
|
||
|
||
|
||
staPtPtpStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ok(1),
|
||
disable(3),
|
||
fault(4),
|
||
reject(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports PackeTime PTP module status.
|
||
ok(1), -- module is enabled and operating without faults
|
||
disable(3), -- module is disabled
|
||
fault(4), -- module is enabled and operating with fault(s)
|
||
reject(5) -- module type between redundant modules do not agree
|
||
"
|
||
::= { staPtPtpEntry 3 }
|
||
|
||
staPtPtpClkSel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clka(1),
|
||
clkb(2),
|
||
clkc(3),
|
||
clkd(4),
|
||
none(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports which clock reference is selected to generate the output reference.
|
||
clka(1), -- Clock A is selected as the Primary clock
|
||
clkb(2), -- Clock B is selected as the Primary clock
|
||
clkc(3), -- Clock C is selected as the Primary clock
|
||
clkd(4), -- Clock D is selected as the Primary clock
|
||
none(5) -- no clock is selected
|
||
"
|
||
::= { staPtPtpEntry 4 }
|
||
|
||
staPtPtpClka OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock A is available.
|
||
"
|
||
::= { staPtPtpEntry 5 }
|
||
|
||
staPtPtpClkb OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock B is available.
|
||
"
|
||
::= { staPtPtpEntry 6 }
|
||
|
||
staPtPtpClkc OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock C is available.
|
||
"
|
||
::= { staPtPtpEntry 7 }
|
||
|
||
staPtPtpClkd OBJECT-TYPE
|
||
SYNTAX ActiveValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports that clock D is available.
|
||
"
|
||
::= { staPtPtpEntry 8 }
|
||
|
||
staPtPtpRednt OBJECT-TYPE
|
||
SYNTAX INTEGER (0..20)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the adjacent slot number if this module is the redundant pair.
|
||
If this module is not redundant, zero is reported.
|
||
"
|
||
::= { staPtPtpEntry 9 }
|
||
|
||
staPtPtpModState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1),
|
||
stdby(2),
|
||
fault(3),
|
||
stdalone(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current operational mode.
|
||
active(1), --If the module is in redundant pair and selected, it shall return active.
|
||
stdby(2), --If the module is in redundant pair but not selected, it shall return stdby (standby).
|
||
fault(3), --If the module disabled, it will return fault.
|
||
stdalone(4) --If the module is not redundant pair, it shall return stdalone (standalone).
|
||
"
|
||
::= { staPtPtpEntry 10 }
|
||
|
||
staPtPtpPAState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
active(1),
|
||
stdby(2),
|
||
fault(3),
|
||
stdalone(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current operational mode.
|
||
active(1), --If service ports are bonded and selected, it shall return active.
|
||
stdby(2), --If service ports are bonded but not selected, it shall return stdby (standby).
|
||
fault(3), --Service port is faulted.
|
||
stdalone(4) --If service ports are not bonded , it shall return stdalone (standalone).
|
||
"
|
||
::= { staPtPtpEntry 11 }
|
||
|
||
staPtPtpTod OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports if the PTP Time of Day is valid or invalid.
|
||
"
|
||
::= { staPtPtpEntry 12 }
|
||
|
||
staPtPtpCommit OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
done(1),
|
||
prog(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the Commit command status.
|
||
1 = done
|
||
2 = in progress
|
||
"
|
||
::= { staPtPtpEntry 13 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 ptpDfltDataSetTable
|
||
-- **************************************************************
|
||
|
||
ptpDfltDataSetTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PtpDfltDataSetEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the PackeTime PTP Management Messages: ptpDefaultDataSet
|
||
"
|
||
::= { statusPtPtp 2 }
|
||
|
||
ptpDfltDataSetEntry OBJECT-TYPE
|
||
SYNTAX PtpDfltDataSetEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The entries of PackeTime PTP Management Messages: ptpDefaultDataSet attributes.
|
||
"
|
||
INDEX { ptpDfltDataSetChassis, ptpDfltDataSetSlot}
|
||
::= { ptpDfltDataSetTable 1 }
|
||
|
||
PtpDfltDataSetEntry ::=
|
||
SEQUENCE {
|
||
ptpDfltDataSetChassis
|
||
INTEGER,
|
||
ptpDfltDataSetSlot
|
||
INTEGER,
|
||
ptpDfltDataSetClockId
|
||
OCTET STRING,
|
||
ptpDfltDataSetClockClass
|
||
INTEGER,
|
||
ptpDfltDataSetClockAccuracy
|
||
INTEGER,
|
||
ptpDfltDataSetTimeTraceable
|
||
TrueValue,
|
||
ptpDfltDataSetFreqTraceable
|
||
TrueValue,
|
||
ptpDfltDataSetDomainNumber
|
||
INTEGER
|
||
}
|
||
|
||
ptpDfltDataSetChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpDfltDataSetEntry 1 }
|
||
|
||
ptpDfltDataSetSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpDfltDataSetEntry 2 }
|
||
|
||
ptpDfltDataSetClockId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(8))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Clock Identity (64-bit value).
|
||
The clock id is a hexadecimal format.
|
||
"
|
||
::= { ptpDfltDataSetEntry 3 }
|
||
|
||
ptpDfltDataSetClockClass OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Master Clock Class
|
||
"
|
||
::= { ptpDfltDataSetEntry 4 }
|
||
|
||
|
||
ptpDfltDataSetClockAccuracy OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
within25ns (32),
|
||
within100ns (33),
|
||
within250ns (34),
|
||
within1000ns (35),
|
||
within2p5us (36),
|
||
within10us (37),
|
||
within25us (38),
|
||
within100us (39),
|
||
within250us (40),
|
||
within1ms (41),
|
||
within2p5ms (42),
|
||
within10ms (43),
|
||
within25ms (44),
|
||
within100ms (45),
|
||
within250ms (46),
|
||
within1sec (47),
|
||
within10sec (48),
|
||
beyond10sec (49),
|
||
unknown (254)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Master Clock Accuracy
|
||
Following is the Clock Accuracy Table
|
||
32 = within 25 ns
|
||
33 = within 100 ns
|
||
34 = within 250 ns
|
||
35 = within 1000 ns
|
||
36 = within 2.5 us
|
||
37 = within 10 us
|
||
38 = within 25 us
|
||
39 = within 100 us
|
||
40 = within 250 us
|
||
41 = within 1 ms
|
||
42 = within 2.5 ms
|
||
43 = within 10 ms
|
||
44 = within 25 ms
|
||
45 = within 100 ms
|
||
46 = within 250 ms
|
||
47 = within 1 sec
|
||
48 = within 10 sec
|
||
49 = beyond 10 sec
|
||
254 = unknown
|
||
"
|
||
::= { ptpDfltDataSetEntry 5 }
|
||
|
||
ptpDfltDataSetTimeTraceable OBJECT-TYPE
|
||
SYNTAX TrueValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Master Time Traceability
|
||
1 = true, time traceable
|
||
2 = false, time not traceable
|
||
"
|
||
::= { ptpDfltDataSetEntry 6 }
|
||
|
||
ptpDfltDataSetFreqTraceable OBJECT-TYPE
|
||
SYNTAX TrueValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Master Frequency Traceability
|
||
1 = true, frequency traceable
|
||
2 = false, frequency not traceable
|
||
"
|
||
::= { ptpDfltDataSetEntry 7 }
|
||
|
||
|
||
ptpDfltDataSetDomainNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP domain number.
|
||
"
|
||
::= { ptpDfltDataSetEntry 8 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 ptpClockDescrTable
|
||
-- **************************************************************
|
||
|
||
ptpClockDescrTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PtpClockDescrEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the PackeTime PTP Management Messages: ptpClockDescription.
|
||
"
|
||
::= { statusPtPtp 3 }
|
||
|
||
ptpClockDescrEntry OBJECT-TYPE
|
||
SYNTAX PtpClockDescrEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Entries of the PackeTime PTP Management Messages: ptpClockDescription attributes.
|
||
"
|
||
INDEX { ptpClockDescrChassis, ptpClockDescrSlot}
|
||
::= { ptpClockDescrTable 1 }
|
||
|
||
PtpClockDescrEntry ::=
|
||
SEQUENCE {
|
||
ptpClockDescrChassis
|
||
INTEGER,
|
||
ptpClockDescrSlot
|
||
INTEGER,
|
||
ptpClockDescrClockType
|
||
INTEGER,
|
||
ptpClockDescrProtocolAddress
|
||
IpAddress,
|
||
ptpClockDescrManufacturerId
|
||
OCTET STRING,
|
||
ptpClockDescrProfileId
|
||
OCTET STRING
|
||
}
|
||
|
||
ptpClockDescrChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpClockDescrEntry 1 }
|
||
|
||
ptpClockDescrSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpClockDescrEntry 2 }
|
||
|
||
ptpClockDescrClockType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ordinary (32768)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Clock Type
|
||
The value 0x8000 meant Ordinary Clock
|
||
"
|
||
::= { ptpClockDescrEntry 3 }
|
||
|
||
ptpClockDescrProtocolAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP IP Address of PTP port.
|
||
"
|
||
::= { ptpClockDescrEntry 4 }
|
||
|
||
ptpClockDescrManufacturerId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(3))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Manufacturer Id.
|
||
The format is a 3 bytes array.
|
||
The Manufacturer Id is 00 B0 AE
|
||
"
|
||
::= { ptpClockDescrEntry 5 }
|
||
|
||
ptpClockDescrProfileId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Profile ID.
|
||
The format is 6 bytes array.
|
||
If Telecom-2008, the profile_id is: 00 00 00 00 00 00
|
||
If ITU G8265.1, the profile_id is: 00 19 A7 00 01 00
|
||
"
|
||
::= { ptpClockDescrEntry 6 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 ptpTimeMessageTable
|
||
-- **************************************************************
|
||
|
||
ptpTimeMessageTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PtpTimeMessageEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the PackeTime PTP Management Messages: ptpTimeMessage.
|
||
"
|
||
::= { statusPtPtp 4 }
|
||
|
||
ptpTimeMessageEntry OBJECT-TYPE
|
||
SYNTAX PtpTimeMessageEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The entries of PackeTime PTP Management Messages: ptpTimeMessage attributes
|
||
"
|
||
INDEX { ptpTimeMessageChassis, ptpTimeMessageSlot}
|
||
::= { ptpTimeMessageTable 1 }
|
||
|
||
PtpTimeMessageEntry ::=
|
||
SEQUENCE {
|
||
ptpTimeMessageChassis
|
||
INTEGER,
|
||
ptpTimeMessageSlot
|
||
INTEGER,
|
||
ptpTimeMessageCurrentTimeSec
|
||
OCTET STRING,
|
||
ptpTimeMessageCurrentTimeNSec
|
||
Counter32
|
||
}
|
||
|
||
ptpTimeMessageChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpTimeMessageEntry 1 }
|
||
|
||
ptpTimeMessageSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpTimeMessageEntry 2 }
|
||
|
||
ptpTimeMessageCurrentTimeSec OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Current Time of seconds.
|
||
The current is a 6-byte a hexadecimal format.
|
||
"
|
||
::= { ptpTimeMessageEntry 3 }
|
||
|
||
ptpTimeMessageCurrentTimeNSec OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP fractional Current Time of nanoseconds
|
||
"
|
||
::= { ptpTimeMessageEntry 4 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 ptpPortDataSetTable
|
||
-- **************************************************************
|
||
|
||
ptpPortDataSetTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PtpPortDataSetEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the PackeTime PTP Management Messages: ptpPortDataSet
|
||
"
|
||
::= { statusPtPtp 5 }
|
||
|
||
ptpPortDataSetEntry OBJECT-TYPE
|
||
SYNTAX PtpPortDataSetEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The entries of PackeTime PTP Management Messages: ptpPortDataSet attributes
|
||
"
|
||
INDEX { ptpPortDataSetChassis, ptpPortDataSetSlot}
|
||
::= { ptpPortDataSetTable 1 }
|
||
|
||
PtpPortDataSetEntry ::=
|
||
SEQUENCE {
|
||
ptpPortDataSetChassis
|
||
INTEGER,
|
||
ptpPortDataSetSlot
|
||
INTEGER,
|
||
ptpPortDataSetClockId
|
||
OCTET STRING,
|
||
ptpPortDataSetPortNumber
|
||
INTEGER,
|
||
ptpPortDataSetPortState
|
||
INTEGER
|
||
}
|
||
|
||
ptpPortDataSetChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpPortDataSetEntry 1 }
|
||
|
||
ptpPortDataSetSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { ptpPortDataSetEntry 2 }
|
||
|
||
ptpPortDataSetClockId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(8))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Clock Identity (64-bit value).
|
||
The port clock id is a hexadecimal format.
|
||
"
|
||
::= { ptpPortDataSetEntry 3 }
|
||
|
||
ptpPortDataSetPortNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Port Number
|
||
"
|
||
::= { ptpPortDataSetEntry 4 }
|
||
|
||
ptpPortDataSetPortState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
notdefined (0),
|
||
initializing (1),
|
||
faulty (2),
|
||
disabled (3),
|
||
listening (4),
|
||
premaster (5),
|
||
master (6),
|
||
passive (7),
|
||
uncalibrated (8),
|
||
slave (9)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the PTP Port State
|
||
Following is the PTP Port State Table
|
||
0 = notdefined
|
||
1 = initializing
|
||
2 = faulty
|
||
3 = disabled
|
||
4 = listening
|
||
5 = premaster, it is a state before becoming a Master
|
||
6 = master
|
||
7 = passive
|
||
8 = uncalibrated
|
||
9 = slave
|
||
"
|
||
::= { ptpPortDataSetEntry 5 }
|
||
|
||
|
||
-- ******************************************
|
||
-- PACKETIME PTP MODULE SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtPtpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtPtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of PackeTime PTP status and settings.
|
||
"
|
||
::= { setupPtPtp 1 }
|
||
|
||
setPtPtpEntry OBJECT-TYPE
|
||
SYNTAX SetPtPtpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The enties of the PackeTime PTP settings and attributes.
|
||
"
|
||
INDEX { setPtPtpChassis, setPtPtpSlot}
|
||
::= { setPtPtpTable 1 }
|
||
|
||
SetPtPtpEntry ::=
|
||
SEQUENCE {
|
||
setPtPtpChassis
|
||
INTEGER,
|
||
setPtPtpSlot
|
||
INTEGER,
|
||
setPtPtpCommit
|
||
INTEGER,
|
||
setPtPtpService
|
||
EnaValue,
|
||
setPtPtpClockId
|
||
OCTET STRING,
|
||
setPtPtpDomain
|
||
INTEGER,
|
||
setPtPtpTimescale
|
||
INTEGER,
|
||
setPtPtpSyncLimit
|
||
INTEGER,
|
||
setPtPtpAnnounceLimit
|
||
INTEGER,
|
||
setPtPtpDelayLimit
|
||
INTEGER,
|
||
setPtPtpDscpState
|
||
EnaValue,
|
||
setPtPtpDscpValue
|
||
INTEGER,
|
||
setPtPtpMaxClient
|
||
INTEGER,
|
||
setPtPtpPortPriority1
|
||
INTEGER,
|
||
setPtPtpPortPriority2
|
||
INTEGER,
|
||
setPtPtpUniLeaseDuration
|
||
INTEGER,
|
||
setPtPtpUniNegotiation
|
||
EnaValue,
|
||
setPtPtpTwostep
|
||
EnaValue,
|
||
setPtPtpProfile
|
||
INTEGER,
|
||
setPtPtpSsmOption
|
||
INTEGER,
|
||
setPtPtpBypass
|
||
OnValue,
|
||
setPtPtpModActive
|
||
YesValue,
|
||
setPtPtpEthRate
|
||
INTEGER,
|
||
setPtPtpVlan
|
||
EnaValue,
|
||
setPtPtpRmvClient
|
||
OCTET STRING
|
||
}
|
||
|
||
setPtPtpChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtPtpEntry 1 }
|
||
|
||
setPtPtpSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtPtpEntry 2 }
|
||
|
||
setPtPtpCommit OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
yes(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Commit all provisioned parameters, this action makes the parameters active.
|
||
This command will also store the parameters to non-volatile memory.
|
||
|
||
Note: This field only has meaning for a writing (1).
|
||
"
|
||
::= { setPtPtpEntry 3 }
|
||
|
||
setPtPtpService OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP service (daemon) to enable or disable.
|
||
This command is applied to both modules if redundant cards installed.
|
||
|
||
1 = Enabled
|
||
2 = Disabled
|
||
"
|
||
::= { setPtPtpEntry 4 }
|
||
|
||
setPtPtpClockId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(8))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clockId is the PTP Port Clock Identity (64-bit value).
|
||
The clockid is a hexadecimal format.
|
||
|
||
Note: users shall enter command COMMIT to take changes into effect
|
||
"
|
||
::= { setPtPtpEntry 5 }
|
||
|
||
setPtPtpDomain OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP port domain.
|
||
Note: users shall enter command COMMIT to take changes into effect
|
||
"
|
||
::= { setPtPtpEntry 6 }
|
||
|
||
setPtPtpTimescale OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ptp (1),
|
||
arb (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set timescale to 'PTP' or 'ARB'.
|
||
Note: users shall enter command COMMIT to take changes into effect
|
||
"
|
||
::= { setPtPtpEntry 7 }
|
||
|
||
setPtPtpSyncLimit OBJECT-TYPE
|
||
SYNTAX INTEGER (-7..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the unicast Sync message rate (2^y).
|
||
The range of the rate value is {-7 to 7}.
|
||
For example, the configurable range is -7, means 128 per second
|
||
"
|
||
::= { setPtPtpEntry 8 }
|
||
|
||
setPtPtpAnnounceLimit OBJECT-TYPE
|
||
SYNTAX INTEGER (-3..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set unicast announce message rate (2^y).
|
||
The range of the rate value is {-3 to 4}.
|
||
For example, the configurable range is -3, means 8 per second
|
||
"
|
||
::= { setPtPtpEntry 9 }
|
||
|
||
setPtPtpDelayLimit OBJECT-TYPE
|
||
SYNTAX INTEGER (-7..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set unicast delay resp message rate (2^y).
|
||
The range of the rate value is {-7 to 7}.
|
||
For example, the configurable range is -6, means 64 per second
|
||
"
|
||
::= { setPtPtpEntry 10 }
|
||
|
||
setPtPtpDscpState OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the DSCP state to enable or disable.
|
||
"
|
||
::= { setPtPtpEntry 11 }
|
||
|
||
setPtPtpDscpValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..63)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set DSCP value.
|
||
"
|
||
::= { setPtPtpEntry 12 }
|
||
|
||
setPtPtpMaxClient OBJECT-TYPE
|
||
SYNTAX INTEGER (64..400)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP max clients.
|
||
"
|
||
::= { setPtPtpEntry 13 }
|
||
|
||
setPtPtpPortPriority1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP Port Priority 1 {0 to 255}.
|
||
"
|
||
::= { setPtPtpEntry 14 }
|
||
|
||
setPtPtpPortPriority2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP Port Priority 2 {0 to 255}.
|
||
"
|
||
::= { setPtPtpEntry 15 }
|
||
|
||
setPtPtpUniLeaseDuration OBJECT-TYPE
|
||
SYNTAX INTEGER (10..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP Max Dynamic Unicast Lease Interval, {10 to 1000}
|
||
"
|
||
::= { setPtPtpEntry 16 }
|
||
|
||
setPtPtpUniNegotiation OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP Unicast Negotiation state: Enable or Disable
|
||
"
|
||
::= { setPtPtpEntry 17 }
|
||
|
||
setPtPtpTwostep OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP Two-Step clock state: Enable or Disable
|
||
Note: users shall enter command COMMIT to take changes into effect
|
||
"
|
||
::= { setPtPtpEntry 18 }
|
||
|
||
setPtPtpProfile OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
telecom2008 (1),
|
||
ituG8265dot1 (4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PTP profile telecom_2008 or itu_g8265_1.
|
||
Note: users shall enter command COMMIT to take changes into effect
|
||
"
|
||
::= { setPtPtpEntry 19 }
|
||
|
||
setPtPtpSsmOption OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
option1 (1),
|
||
option2 (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PTP ssm-option in Option 1 or Option 2.
|
||
"
|
||
::= { setPtPtpEntry 20 }
|
||
|
||
setPtPtpBypass OBJECT-TYPE
|
||
SYNTAX OnValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the clock C state, or bypass clock, to enabled or disabled.
|
||
"
|
||
::= { setPtPtpEntry 30 }
|
||
|
||
setPtPtpModActive OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the specified module in the redundant pair to be Active.
|
||
Note1: This command only applies when the module in the redundant pair.
|
||
Note2: This field only has meaning for a writing (1).
|
||
Note3: Don't apply COMMIT after this command.
|
||
"
|
||
::= { setPtPtpEntry 31 }
|
||
|
||
setPtPtpEthRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
all (0),
|
||
r100 (1),
|
||
r1000 (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the PTP port transmission rate.
|
||
all - means auto negotiation capable of both 100M and 1000Mbits/s rate.
|
||
r100 - means auto negotiation capable of only 100Mbit/s rate.
|
||
r1000 - means auto negotiation capable of only 1000Mbit/s rate
|
||
|
||
Note: this setting is only applied to the copper SFP, not fiber.
|
||
If fiber SFP installed, this setting is ignored.
|
||
"
|
||
::= { setPtPtpEntry 32 }
|
||
|
||
setPtPtpVlan OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN state.
|
||
1 = Enabled
|
||
2 = Disabled
|
||
|
||
Users must COMMIT for changes into effect.
|
||
"
|
||
::= { setPtPtpEntry 33 }
|
||
|
||
setPtPtpRmvClient OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(8))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This is an action command and not a configuration command.
|
||
This command remove a client from a ptp client list.
|
||
The clockid is a hexadecimal format.
|
||
|
||
Note: this field only has meansing for write action with proper clock id.
|
||
When it read, it always returns as all zero octet string.
|
||
"
|
||
::= { setPtPtpEntry 34 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME PTP MODULE PORT SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setPtpPortTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtpPortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set PackeTime PTP ethernet port information.
|
||
"
|
||
::= { setupPtPtp 2 }
|
||
|
||
|
||
setPtpPortEntry OBJECT-TYPE
|
||
SYNTAX SetPtpPortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"PackeTime PTP ethernet port state and settings information.
|
||
setPtPtpPortChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtPtpPortSlot
|
||
Identifies which slot is being addressed.
|
||
setPtPtpPortNum
|
||
Identifies which port is being addressed.
|
||
setPtPtpPortAddr
|
||
Set the port IP address
|
||
setPtPtpPortMask
|
||
Set the port network mask
|
||
setPtPtpPortGate
|
||
Set the port gateway address
|
||
"
|
||
INDEX { setPtpPortChassis, setPtpPortSlot, setPtpPortNum}
|
||
::= { setPtpPortTable 1 }
|
||
|
||
SetPtpPortEntry ::=
|
||
SEQUENCE {
|
||
setPtpPortChassis
|
||
INTEGER,
|
||
setPtpPortSlot
|
||
INTEGER,
|
||
setPtpPortNum
|
||
INTEGER,
|
||
setPtpPortAddr
|
||
IpAddress,
|
||
setPtpPortMask
|
||
IpAddress,
|
||
setPtpPortGate
|
||
IpAddress
|
||
}
|
||
|
||
setPtpPortChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
"
|
||
::= { setPtpPortEntry 1 }
|
||
|
||
setPtpPortSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
"
|
||
::= { setPtpPortEntry 2 }
|
||
|
||
setPtpPortNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which port is being addressed.
|
||
This chassis, slot, and port number uniquely identify each entry.
|
||
|
||
PTPTP ethernet interface number.
|
||
1 = Service Port A
|
||
2 = Maintenance Port
|
||
"
|
||
::= { setPtpPortEntry 3 }
|
||
|
||
setPtpPortAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port IP address
|
||
"
|
||
::= { setPtpPortEntry 4 }
|
||
|
||
setPtpPortMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port network mask
|
||
"
|
||
::= { setPtpPortEntry 5 }
|
||
|
||
setPtpPortGate OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the port gateway address
|
||
"
|
||
::= { setPtpPortEntry 6 }
|
||
|
||
|
||
-- ******************************************
|
||
-- PACKETIME PTP VLAN GROUP
|
||
-- ******************************************
|
||
|
||
setPtpVlanTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetPtpVlanEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of PackeTime PTP vlan attributes.
|
||
The Virtural Local Area Network is implemented per IEEE 802.1Q.
|
||
"
|
||
::= { setupPtPtp 3 }
|
||
|
||
setPtpVlanEntry OBJECT-TYPE
|
||
SYNTAX SetPtpVlanEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A PackeTime PTP vlan attributes and settings:
|
||
setPtPtpVlanChassis
|
||
Identifies which chassis is being addressed.
|
||
setPtPtpVlanSlot
|
||
Identifies which slot is being addressed.
|
||
setPtpVlanIndex
|
||
Set the VLAN index number for PTPTP.
|
||
setPtpVlanState
|
||
Enable or Disable of a given VLAN Entry
|
||
setPtpVlanAddr
|
||
VLAN IP Address (If 0.0.0.0, and then SET, this will delete this entry)
|
||
note: This field has to set first with a valid non-zero IP address, if you want to add a new entry
|
||
setPtpVlanMask
|
||
VLAN Network Mask
|
||
setPtpVlanGate
|
||
VLAN Gateway
|
||
setPtpVlanId
|
||
VLAN ID
|
||
setPtpVlanPriority
|
||
VLAN Priority
|
||
Note: The module setPtPtpVlan set must be enabled, and each of the enabled entires
|
||
has meaning.
|
||
"
|
||
INDEX { setPtpVlanChassis, setPtpVlanSlot, setPtpVlanIndex}
|
||
::= { setPtpVlanTable 1 }
|
||
|
||
SetPtpVlanEntry ::=
|
||
SEQUENCE {
|
||
setPtpVlanChassis
|
||
INTEGER,
|
||
setPtpVlanSlot
|
||
INTEGER,
|
||
setPtpVlanIndex
|
||
INTEGER,
|
||
setPtpVlanState
|
||
EnaValue,
|
||
setPtpVlanAddr
|
||
IpAddress,
|
||
setPtpVlanMask
|
||
IpAddress,
|
||
setPtpVlanGate
|
||
IpAddress,
|
||
setPtpVlanId
|
||
INTEGER,
|
||
setPtpVlanPriority
|
||
INTEGER
|
||
}
|
||
|
||
setPtpVlanChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtpVlanEntry 1 }
|
||
|
||
setPtpVlanSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { setPtpVlanEntry 2 }
|
||
|
||
setPtpVlanIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN index number for PTP.
|
||
"
|
||
::= { setPtpVlanEntry 3 }
|
||
|
||
setPtpVlanState OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable or Disable of a given VLAN entry
|
||
Note: The value has meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtpVlanEntry 4 }
|
||
|
||
setPtpVlanAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Ethernet VLAN Port IP Address
|
||
Note: you must have IP address in order to add or change other fields.
|
||
This field has to set first with a valid non-zero IP address, if you want to add a new entry
|
||
If the IP is 0.0.0.0, and use the SET operation, this mean delete this entry.
|
||
"
|
||
::= { setPtpVlanEntry 5 }
|
||
|
||
setPtpVlanMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Ethernet VLAN Port Network Mask
|
||
"
|
||
::= { setPtpVlanEntry 6 }
|
||
|
||
setPtpVlanGate OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Ethernet VLAN Port Gateway Address
|
||
"
|
||
::= { setPtpVlanEntry 7 }
|
||
|
||
setPtpVlanId OBJECT-TYPE
|
||
SYNTAX INTEGER (2..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the VLAN ID (2..4094) for Service Port A
|
||
Note: The value has meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtpVlanEntry 8 }
|
||
|
||
|
||
setPtpVlanPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"VLAN Priority (0..7) for Service Port A
|
||
Note: The value has meaning, only when the VLAN is enabled
|
||
"
|
||
::= { setPtpVlanEntry 9 }
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 PACKETIME PTP GETCLIENTLIST GROUP
|
||
-- **************************************************************
|
||
|
||
ptpclientTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PtpclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports PackeTime PTP client list entries.
|
||
|
||
Usage: you need to specify a PTP blade address in ptpclientParmLoc, and
|
||
then execute the command ptpclientCmdXeq first. The PTP client list will be
|
||
saved. This ptpclientTable will display all the PTP client list contents
|
||
of this saved information.
|
||
"
|
||
::= { ptpclient 1 }
|
||
|
||
ptpclientEntry OBJECT-TYPE
|
||
SYNTAX PtpclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports PackeTime PTP client list containing each PTP client status value.
|
||
ptpclientChassis
|
||
Identifies which chassis is being addressed.
|
||
ptpclientSlot
|
||
Identifies which slot is being addressed.
|
||
ptpclientData
|
||
Reports the contents of the Client data TLV:
|
||
"
|
||
INDEX { ptpclientChassis, ptpclientSlot}
|
||
::= { ptpclientTable 1 }
|
||
|
||
PtpclientEntry ::=
|
||
SEQUENCE {
|
||
ptpclientChassis
|
||
INTEGER,
|
||
ptpclientSlot
|
||
INTEGER,
|
||
ptpclientData
|
||
OCTET STRING
|
||
}
|
||
|
||
ptpclientChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { ptpclientEntry 1 }
|
||
|
||
ptpclientSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis and slot number uniquely identify each entry.
|
||
"
|
||
::= { ptpclientEntry 2 }
|
||
|
||
ptpclientData OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(40))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the contents of the Client data TLV:
|
||
INTEGER - mode, 0:dynamic, 1:static
|
||
INTEGER - ip address
|
||
OCTET - clock id
|
||
INTEGER - VLAN ID, if 0xffff, then there is no vlan
|
||
INTEGER - VLAN Priority
|
||
INTEGER - Sync Limit (signed value), if 99, the disable
|
||
INTEGER - Announce Limit (signed value), if 99, the disable
|
||
INTEGER - Delay Limit (signed value), if 99, the disable
|
||
"
|
||
::= { ptpclientEntry 3 }
|
||
|
||
|
||
-- ******************************************
|
||
-- SCALAR METHODS (GETCLIENTLIST)
|
||
-- ******************************************
|
||
|
||
ptpclientParmLoc OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..10))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the ports VLAN address.
|
||
where
|
||
x is the chassis number: in this case is 1-5,
|
||
A is the constant letter 'A', and is chassis/slot sepearator.
|
||
y is the slot number: (range is 1 to 14)
|
||
|
||
For example: 1A6 means this port located at chassis 1, slot 6
|
||
|
||
Note: the user must specify valid PTP address.
|
||
The valid port must be physically installed in the system.
|
||
"
|
||
::= { ptpclient 2 }
|
||
|
||
ptpclientCmdXeq OBJECT-TYPE
|
||
SYNTAX YesValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports the current client list in the module.
|
||
The max number of client is 400
|
||
"
|
||
::= { ptpclient 3 }
|
||
|
||
|
||
-- **************************************************************
|
||
-- SSU2000 SYNCE STATUS GROUP
|
||
-- **************************************************************
|
||
|
||
staSynceTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF StaSynceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of SyncE status information:
|
||
port_direction, ethernet_mode, rx_ssm, and tx_ssm
|
||
"
|
||
::= { statusSynce 1 }
|
||
|
||
staSynceEntry OBJECT-TYPE
|
||
SYNTAX StaSynceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The entries of SyncE status attributes.
|
||
"
|
||
INDEX { staSynceChassis, staSynceSlot}
|
||
::= { staSynceTable 1 }
|
||
|
||
StaSynceEntry ::=
|
||
SEQUENCE {
|
||
staSynceChassis
|
||
INTEGER,
|
||
staSynceSlot
|
||
INTEGER,
|
||
staSyncePortDirection
|
||
INTEGER,
|
||
staSynceEthernetMode
|
||
INTEGER,
|
||
staSynceRxSsm
|
||
INTEGER,
|
||
staSynceTxSsm
|
||
INTEGER
|
||
}
|
||
|
||
staSynceChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staSynceEntry 1 }
|
||
|
||
staSynceSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot position is being addressed.
|
||
This chassis number and slot number uniquely identify each inventory entry.
|
||
"
|
||
::= { staSynceEntry 2 }
|
||
|
||
staSyncePortDirection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
input (1),
|
||
output (2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SyncE Port Direction to be either Output or Input.
|
||
The output port is a SyncE master port, and input port is a SyncE slave port.
|
||
"
|
||
::= { staSynceEntry 3 }
|
||
|
||
staSynceEthernetMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
synchronous (1),
|
||
asynchronous (2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SyncE operated on Ethernet to be either synchronous or
|
||
asynchronous. It is synchronous mode, when an optical SFP is detected
|
||
at an Ethernet port. It is an asynchronous mode, when an electrical SFP
|
||
is detected at an Ethernet port, or there is no SFP detected.
|
||
"
|
||
::= { staSynceEntry 4 }
|
||
|
||
staSynceRxSsm OBJECT-TYPE
|
||
SYNTAX INTEGER (0..15 | 255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SyncE the current rx ssm value (0 .. 15).
|
||
If 255, SyncE does not receive ESMC messages
|
||
"
|
||
::= { staSynceEntry 5 }
|
||
|
||
staSynceTxSsm OBJECT-TYPE
|
||
SYNTAX INTEGER (0..15 | 255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reports SyncE the current tx ssm value (0 .. 15).
|
||
If 255, SyncE does not transmit ESMC messages
|
||
"
|
||
::= { staSynceEntry 6 }
|
||
|
||
-- ******************************************
|
||
-- PACKETIME SYNCE SETUP GROUP
|
||
-- ******************************************
|
||
|
||
setSynceTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SetSynceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A list of SyncE settings.
|
||
"
|
||
::= { setupSynce 1 }
|
||
|
||
setSynceEntry OBJECT-TYPE
|
||
SYNTAX SetSynceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The enties of the SyncE settings and attributes.
|
||
"
|
||
INDEX { setSynceChassis, setSynceSlot}
|
||
::= { setSynceTable 1 }
|
||
|
||
SetSynceEntry ::=
|
||
SEQUENCE {
|
||
setSynceChassis
|
||
INTEGER,
|
||
setSynceSlot
|
||
INTEGER,
|
||
setSyncePortDirection
|
||
INTEGER,
|
||
setSynceEsmc
|
||
EnaValue,
|
||
setSynceQl
|
||
EnaValue,
|
||
setSynceOutQl
|
||
INTEGER
|
||
}
|
||
|
||
setSynceChassis OBJECT-TYPE
|
||
SYNTAX INTEGER (1..5)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which chassis is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setSynceEntry 1 }
|
||
|
||
setSynceSlot OBJECT-TYPE
|
||
SYNTAX INTEGER (1..20)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies which slot is being addressed.
|
||
This chassis number and slot number uniquely identify each entry.
|
||
"
|
||
::= { setSynceEntry 2 }
|
||
|
||
setSyncePortDirection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
input (1),
|
||
output (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set SyncE Port Direction to be either Output or Input.
|
||
The output port is a SyncE master port, and input port
|
||
is a SyncE slave port.
|
||
"
|
||
::= { setSynceEntry 3 }
|
||
|
||
setSynceEsmc OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Ethernet Synchronization Message Channel (ESMC)
|
||
state is either Enable or Disable. If ESMC is enabled,
|
||
the ESMC is used; otherwise, it shall not be used.
|
||
"
|
||
::= { setSynceEntry 4 }
|
||
|
||
setSynceQl OBJECT-TYPE
|
||
SYNTAX EnaValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Quality Level (QL, i.e. SSM) in the ESMC is either
|
||
Enabled or Disabled. If QL is enabled, the SSM in the ESMC
|
||
is used; otherwise, it shall not be used.
|
||
"
|
||
::= { setSynceEntry 5 }
|
||
|
||
setSynceOutQl OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
bidirectional (1),
|
||
unidirectional (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the Output QL mode is either unidirectional or bidirectional.
|
||
In the unidirectional mode, the rx ESMC from the downstream NE is
|
||
ignored. The tx SSM will be determined by the system clock state only.
|
||
In the bidirectional mode, the rx ESMC from the downstream NE is not
|
||
ignored but is used for testing purposes and some interoperability cases.
|
||
"
|
||
::= { setSynceEntry 6 }
|
||
|
||
|
||
END
|