-- %DNP% $Id: ERICSSON-ROUTER-SFP-MIB.my,v 1.1.12.4 2011/02/22 17:26:17 thatcher Exp $
-- %DNP% $Source: /cvsroot/pkt/sw/se/xc/bsd/config/snmp/mibs/Attic/ERICSSON-ROUTER-SFP-MIB.my,v $
-- *****************************************************************
-- ERICSSON-ROUTER-SFP-MIB Small Form-factor Pluggable MIB
--
-- Copyright (c) 2008, 2010-2011, 2015 Ericsson AB
-- All rights reserved.
--
-- *****************************************************************
ERICSSON-ROUTER-SFP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
DateAndTime
FROM SNMPv2-TC
EriRouterSlot,
EriRouterPort
FROM ERICSSON-ROUTER-TC
EriRouterAlarmId,
EriRouterAlarmServiceAffecting
FROM ERICSSON-ROUTER-ALARM-TC
IANAItuProbableCause,
IANAItuEventType
FROM IANA-ITU-ALARM-TC-MIB
ItuPerceivedSeverity
FROM ITU-ALARM-TC-MIB
eriRouterMgmt
FROM ERICSSON-ROUTER-SMI;
eriRouterSfpMonMIB MODULE-IDENTITY
LAST-UPDATED "201501141800Z" -- Jan 14, 2015
ORGANIZATION "Ericsson AB"
CONTACT-INFO
" Ericsson AB.
Postal: 100 Headquarters Dr
San Jose, CA 95134
USA
Phone: +1 408 750 5000
Fax: +1 408 750 5599
"
DESCRIPTION
"The MIB used to manage the SFP (Small Form Factor Pluggable)
devices."
REVISION "201501141800Z" -- Jan 14, 2015
DESCRIPTION
"Updated RBN/rbn/Rbn as ERICSSON-ROUTER/eriRouter/EriRouter
to migrate RBN MIB to ERICSSON MIB."
REVISION "201003020000Z" -- March 2, 2010
DESCRIPTION
"Update CONTACT-INFO, add Unsigned32 to IMPORTS clause."
REVISION "200808200000Z" -- August 20, 2008
DESCRIPTION
"Initial version."
::= { eriRouterMgmt 49 }
eriRouterSfpMonMIBNotifications OBJECT IDENTIFIER
::= { eriRouterSfpMonMIB 0 }
eriRouterSfpMonMIBObjects OBJECT IDENTIFIER
::= { eriRouterSfpMonMIB 1 }
eriRouterSfpMonMIBConformance OBJECT IDENTIFIER
::= { eriRouterSfpMonMIB 2 }
-- MIB Objects
eriRouterSfpAlarmActiveTable OBJECT-TYPE
SYNTAX SEQUENCE OF EriRouterSfpAlarmActiveEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the SFP alarms currently
active on the SFP."
::= { eriRouterSfpMonMIBObjects 1 }
eriRouterSfpAlarmActiveEntry OBJECT-TYPE
SYNTAX EriRouterSfpAlarmActiveEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries appear in this table when alarms are
raised. They are removed when the alarms are cleared."
INDEX {eriRouterSfpActiveAlarmIndex }
::= { eriRouterSfpAlarmActiveTable 1 }
EriRouterSfpAlarmActiveEntry ::= SEQUENCE {
eriRouterSfpActiveAlarmIndex Unsigned32,
eriRouterSfpAlarmCardSlot EriRouterSlot,
eriRouterSfpAlarmPort EriRouterPort,
eriRouterSfpAlarmId EriRouterAlarmId,
eriRouterSfpAlarmSeverity ItuPerceivedSeverity,
eriRouterSfpAlarmType IANAItuEventType,
eriRouterSfpAlarmDateAndTime DateAndTime,
eriRouterSfpAlarmDescription SnmpAdminString,
eriRouterSfpAlarmProbableCause IANAItuProbableCause,
eriRouterSfpAlarmServiceAffecting EriRouterAlarmServiceAffecting
}
eriRouterSfpActiveAlarmIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A monotonically increasing integer index. It wraps
back to 1 after it reaches its maximum value."
::= { eriRouterSfpAlarmActiveEntry 1 }
eriRouterSfpAlarmCardSlot OBJECT-TYPE
SYNTAX EriRouterSlot
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The chassis slot number in which the card is present where the SFP plugged in."
::= { eriRouterSfpAlarmActiveEntry 2 }
eriRouterSfpAlarmPort OBJECT-TYPE
SYNTAX EriRouterPort
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number where the SFP plugged in."
::= { eriRouterSfpAlarmActiveEntry 3 }
eriRouterSfpAlarmId OBJECT-TYPE
SYNTAX EriRouterAlarmId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An identifier for the alarm."
::= { eriRouterSfpAlarmActiveEntry 4 }
eriRouterSfpAlarmSeverity OBJECT-TYPE
SYNTAX ItuPerceivedSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The perceived severity of the alarm."
::= { eriRouterSfpAlarmActiveEntry 5 }
eriRouterSfpAlarmType OBJECT-TYPE
SYNTAX IANAItuEventType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the alarm."
::= { eriRouterSfpAlarmActiveEntry 6 }
eriRouterSfpAlarmDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local date and time when the alarm was raised"
::= { eriRouterSfpAlarmActiveEntry 7 }
eriRouterSfpAlarmDescription OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A text string which conveys additional information
about the alarm."
::= { eriRouterSfpAlarmActiveEntry 8 }
eriRouterSfpAlarmProbableCause OBJECT-TYPE
SYNTAX IANAItuProbableCause
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The probable cause for this alarm."
::= { eriRouterSfpAlarmActiveEntry 9 }
eriRouterSfpAlarmServiceAffecting OBJECT-TYPE
SYNTAX EriRouterAlarmServiceAffecting
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the alarm is perceived to be
service impacting."
::= { eriRouterSfpAlarmActiveEntry 10 }
-- Notifications
eriRouterSfpAlarm NOTIFICATION-TYPE
OBJECTS {
eriRouterSfpAlarmCardSlot,
eriRouterSfpAlarmPort,
eriRouterSfpAlarmId,
eriRouterSfpAlarmSeverity,
eriRouterSfpAlarmType,
eriRouterSfpAlarmDateAndTime,
eriRouterSfpAlarmDescription,
eriRouterSfpAlarmProbableCause
}
STATUS current
DESCRIPTION
"An eriRouterSfpAlarm notification signifies that an
alarm has been raised or cleared on a SFP"
::= { eriRouterSfpMonMIBNotifications 1 }
-- Conformance Statements
eriRouterSfpMonMIBGroups OBJECT IDENTIFIER
::= { eriRouterSfpMonMIBConformance 1 }
eriRouterSfpMonMIBCompliances OBJECT IDENTIFIER
::= { eriRouterSfpMonMIBConformance 2 }
eriRouterSfpMonMIBObjectGroup OBJECT-GROUP
OBJECTS { eriRouterSfpAlarmCardSlot,
eriRouterSfpAlarmPort,
eriRouterSfpAlarmId,
eriRouterSfpAlarmType,
eriRouterSfpAlarmDateAndTime,
eriRouterSfpAlarmDescription,
eriRouterSfpAlarmProbableCause,
eriRouterSfpAlarmSeverity,
eriRouterSfpAlarmServiceAffecting
}
STATUS current
DESCRIPTION
"A collection of objects providing active SFP Alarm information"
::= { eriRouterSfpMonMIBGroups 1 }
eriRouterSfpMonMIBNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { eriRouterSfpAlarm
}
STATUS current
DESCRIPTION
"A collection of notifications providing SFP fault condition"
::= {eriRouterSfpMonMIBGroups 2 }
eriRouterSfpMonMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the Sfp active alarm MIB"
MODULE -- this module
GROUP eriRouterSfpMonMIBObjectGroup
DESCRIPTION
"This group is mandatory for devices which contain Ericsson Approved SFP/XFP" -- Sept 28, 2008
GROUP eriRouterSfpMonMIBNotificationGroup
DESCRIPTION
"This group is mandatory for devices which contain SFP/XFP Alarmmonitoring capabilities"
::= { eriRouterSfpMonMIBCompliances 1 }
END