-- This module defines enterprise MIBs for UACs
--
-- Copyright (c) 1999-2010, Juniper Networks, Inc.
-- All rights reserved.
NETSCREEN-UAC-MIB DEFINITIONS ::= BEGIN
IMPORTS
netscreenUAC
FROM NETSCREEN-SMI
Integer32, MODULE-IDENTITY, OBJECT-TYPE
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
;
netscreenUACMibModule MODULE-IDENTITY
LAST-UPDATED "201004140000Z" -- Apr 14, 2010
ORGANIZATION
"Juniper Networks, Inc."
CONTACT-INFO
"Customer Support
1194 North Mathilda Avenue
Sunnyvale, California 94089-1206
USA
Tel: 1-800-638-8296
E-mail: customerservice@juniper.net
HTTP://www.juniper.net"
DESCRIPTION
"This module defines the object that are used to monitor all
UAC"
REVISION "201004140000Z" -- Apr 14, 2010
DESCRIPTION
"Creation Date"
::= { netscreenUAC 0 }
nsUACActiveUsers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active users on this box, base on auth entry from UAC controler"
::= { netscreenUAC 1 }
NsUACControlerStatusEntry ::= SEQUENCE
{
nsUACControlerId Integer32,
nsUACControlerName DisplayString,
nsUACControlerHost DisplayString,
nsUACConnectionStatus Integer32
}
nsUACControlerStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF NsUACControlerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"NetScreen UAC controler status table"
::= { netscreenUAC 2}
nsUACControlerStatusEntry OBJECT-TYPE
SYNTAX NsUACControlerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in the table holds a set of configuration
parameters associated with an instance of secure UAC."
INDEX
{ nsUACControlerID}
::= { nsUACControlerStatusTable 1 }
nsUACControlerId OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for UAC table. Its value ranges between 1 and
65535 and may not be contiguous. the index has no other
meaning but a pure index"
::= { nsUACControlerStatusEntry 1 }
nsUACControlerName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Secure UAC name."
::= { nsUACControlerStatusEntry 2 }
nsUACControlerHost OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Secure UAC name."
::= { nsUACControlerStatusEntry 3 }
nsUACConnectionStatus OBJECT-TYPE
SYNTAX Integer32 {
disconnected(0),
connected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"UAC controler status table"
::= { nsUACControlerStatusEntry 4 }
nsUACGlobalStatus OBJECT-TYPE
SYNTAX Integer32 {
disconnected(0),
connected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"To indicate whether there is at least one heathy IC-IE connection"
::= { netscreenUAC 3 }
END