towerops/priv/mibs/cisco/CISCOSB-STACK-MIB
Graham McIntire b4f8b40b7f
Include MIB files in Docker image instead of using PVC
- Remove PVC volume mount from k8s/deployment.yaml
- Delete k8s/mib-pvc.yaml (no longer needed)
- Update .gitignore to commit MIB files to git
- Add mix import_mibs task to copy MIBs from LibreNMS
- Add all MIB files from priv/mibs/ to git

This fixes the multi-attach volume error in Kubernetes where new pods
couldn't start because the RWO (ReadWriteOnce) PVC was attached to the
old pod. MIBs are now part of the Docker image and can be used by all
pods simultaneously.
2026-01-19 14:01:03 -06:00

140 lines
3.9 KiB
Text

CISCOSB-STACK-MIB DEFINITIONS ::= BEGIN
-- Title: CISCOSB LOCALIZATION ROS
-- This Private MIB supports the unit id configuration for stack of ROS products
-- Version: 7.40
-- Date: 21 Nov 2005
-- 23-May-2012 Update unit id from 4 to 8 units maximum
-- 19-Dec-2012 Support Lion Native and advanced-hybrid-xg
--
-- 01-Nov-2005 Add rlStackUnitMacAddressAfterReset
-- 21-Nov-2005 Change range of rlStackActiveUnitIdAfterReset
-- 21 mar 2011 In version 7.50, unit id configuration for hybrid stack
-- 10 Oct 2011 Add port-speed-down
IMPORTS
MacAddress FROM SNMPv2-TC
switch001 FROM CISCOSB-MIB OBJECT-TYPE,
MODULE-IDENTITY FROM SNMPv2-SMI
TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC;
rlStack MODULE-IDENTITY
LAST-UPDATED "200504140000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Postal: 170 West Tasman Drive
San Jose , CA 95134-1706
USA
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
DESCRIPTION
"The private MIB module definition for stack."
REVISION "200504140000Z"
DESCRIPTION
"Initial revision."
::= { switch001 107 }
rlStackActiveUnitIdTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlStackActiveUnitIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The table listing the active unit id of the requested unit."
::= {rlStack 1 }
rlStackActiveUnitIdEntry OBJECT-TYPE
SYNTAX RlStackActiveUnitIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the rlStackActiveUnitIdTable."
INDEX {rlStackCurrentUnitId }
::= {rlStackActiveUnitIdTable 1 }
RlStackActiveUnitIdEntry ::= SEQUENCE {
rlStackCurrentUnitId INTEGER,
rlStackActiveUnitIdAfterReset INTEGER
}
rlStackCurrentUnitId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unit number device, which is the active unit id"
::= {rlStackActiveUnitIdEntry 1 }
rlStackActiveUnitIdAfterReset OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the unit id that will be after reset."
::= {rlStackActiveUnitIdEntry 2 }
rlStackUnitModeAfterReset OBJECT-TYPE
SYNTAX INTEGER {
standalone(1),
stack(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set unit type that will be after reset, standalone or stack."
::= {rlStack 2 }
rlStackUnitMode OBJECT-TYPE
SYNTAX INTEGER {
standalone(1),
stack(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"show unit type standalone or stack."
::= {rlStack 3 }
rlStackUnitMacAddressAfterReset OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MAC address used by this bridge after rest."
REFERENCE
"IEEE 802.1D-1990: Sections 6.4.1.1.3 and 3.12.5"
::= { rlStack 4 }
rlStackTopology OBJECT-TYPE
SYNTAX INTEGER {
topology-chain(1),
topology-ring(2),
topology-star(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"show stack topology type"
::= {rlStack 6 }
---------------
-- rlStackMode
---------------
rlStackMode OBJECT-TYPE
SYNTAX INTEGER {
native(1),
hybrid(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the stack mode that would be taken after reset - native or hybrid."
::= { rlStack 7}
END