- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
559 lines
21 KiB
Text
559 lines
21 KiB
Text
CISCOSB-EVENTS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, DisplayString,
|
|
TruthValue, RowStatus FROM SNMPv2-TC
|
|
switch001 FROM CISCOSB-MIB
|
|
Counter FROM RFC1155-SMI
|
|
InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
|
RlSmartPortsMacroNameOrZero FROM CISCOSB-SMARTPORTS-MIB;
|
|
|
|
rlEventsMib MODULE-IDENTITY
|
|
LAST-UPDATED "201009110000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
|
|
CONTACT-INFO
|
|
"Postal: 170 West Tasman Drive
|
|
San Jose , CA 95134-1706
|
|
USA
|
|
|
|
|
|
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
|
|
|
|
DESCRIPTION
|
|
"MTS events MIB."
|
|
REVISION "201009110000Z"
|
|
DESCRIPTION
|
|
"Initial revision."
|
|
::= { switch001 150 }
|
|
|
|
--
|
|
-- rlEvents MIB
|
|
--
|
|
|
|
SmartPortType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Supported smart port types."
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
default(2),
|
|
printer(3),
|
|
desktop(4),
|
|
guest(5),
|
|
server(6),
|
|
host(7),
|
|
ip-camera(8),
|
|
ip-phone(9),
|
|
ip-phone-desktop(10),
|
|
switch(11),
|
|
router(12),
|
|
ap(13)
|
|
}
|
|
SmartPortMacroParameterName ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Smart macro parameter name."
|
|
SYNTAX DisplayString(SIZE(1..32))
|
|
|
|
SmartPortMacroParameterValue ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Smart macro parameter value."
|
|
SYNTAX DisplayString(SIZE(1..80))
|
|
|
|
SmartPortMacroType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Smart macro type - built-in or user-defined."
|
|
SYNTAX INTEGER {built-in(1), user-defined(2)}
|
|
|
|
SmartPortMacroParameterOrder ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Smart macro parameter order."
|
|
SYNTAX INTEGER {single(1), first(2), middle(3), last(4)}
|
|
|
|
rlPortEvents OBJECT IDENTIFIER ::= { rlEventsMib 1}
|
|
|
|
rlAutoSmartPortAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
controlled(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"disabled - Auto Smart port feature is administratively disabled.
|
|
enabled - Auto Smart port feature is administratively enabled.
|
|
controlled - Auto Smart port feature is administratively controlled by VOICE VLAN.
|
|
"
|
|
DEFVAL {controlled}
|
|
::= { rlPortEvents 1 }
|
|
|
|
rlAutoSmartPortOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"disabled - Auto Smart port feature is operationally disabled.
|
|
enabled - Auto Smart port feature is operationally enabled.
|
|
"
|
|
DEFVAL {disabled}
|
|
::= { rlPortEvents 2 }
|
|
|
|
rlAutoSmartPortLastVoiceVlanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicated last status set by VOICE VLAN feature.
|
|
If rlAutoSmartPortAdminStatus has 'controlled' value then the value of this object is the same as rlAutoSmartPortOperStatus.
|
|
|
|
enabled - Auto Smart port feature should be operationally enabled, if rlAutoSmartPortAdminStatus has 'controlled' value.
|
|
disabled - Auto Smart port feature should be operationally disabled, if rlAutoSmartPortAdminStatus has 'controlled' value
|
|
"
|
|
DEFVAL {disabled}
|
|
::= { rlPortEvents 3}
|
|
|
|
rlAutoSmartPortLastVoiceVlanId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicated last VOICE VLAN ID set by VOICE VLAN feature."
|
|
::= { rlPortEvents 4}
|
|
|
|
rlAutoSmartPortLearningProtocols OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
cdp (0),
|
|
lldp (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cdp - Information about device type of neighboring devices(s) is learnt
|
|
via CDP (Cisco Discovery Protocol) advertisements.
|
|
lldp - Information about device type of neighboring devices(s) is learnt
|
|
via LLDP (Link Layer Discovery Protocol ) advertisements. "
|
|
::= { rlPortEvents 5 }
|
|
|
|
|
|
rlAutoSmartPortTypesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlAutoSmartPortTypesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table is used to keep all the information related to a specific port type."
|
|
::= { rlPortEvents 6 }
|
|
|
|
rlAutoSmartPortTypesEntry OBJECT-TYPE
|
|
SYNTAX RlAutoSmartPortTypesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the rlAutoSmartPortTypesTable."
|
|
INDEX { rlAutoSmartPortTypesType }
|
|
::= { rlAutoSmartPortTypesTable 1 }
|
|
|
|
RlAutoSmartPortTypesEntry ::= SEQUENCE {
|
|
rlAutoSmartPortTypesType SmartPortType,
|
|
rlAutoSmartPortTypeStatus INTEGER,
|
|
rlAutoSmartPortMacro RlSmartPortsMacroNameOrZero,
|
|
rlAutoSmartPortTypesRevertToDefaultMacro TruthValue,
|
|
rlAutoSmartPortTypesRevertToDefaultParams TruthValue,
|
|
rlAutoSmartPortTypesBuiltinMacro SmartPortMacroType
|
|
|
|
|
|
}
|
|
|
|
rlAutoSmartPortTypesType OBJECT-TYPE
|
|
SYNTAX SmartPortType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Smart port type."
|
|
::= { rlAutoSmartPortTypesEntry 1 }
|
|
|
|
rlAutoSmartPortTypeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { enabled(1), disabled(2), default(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Smart port type global status. "
|
|
::= { rlAutoSmartPortTypesEntry 2 }
|
|
|
|
rlAutoSmartPortMacro OBJECT-TYPE
|
|
SYNTAX RlSmartPortsMacroNameOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Macro to be activated when a port is set to the smart port type indicated
|
|
by rlAutoSmartPortTypesType. The macro whose name is 'no_'<rlAutoSmartPortMacro>
|
|
is activated when a port ceases to be of this smart port type. "
|
|
::= { rlAutoSmartPortTypesEntry 3 }
|
|
|
|
|
|
rlAutoSmartPortTypesRevertToDefaultMacro OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will cause the smart port type macro associated with this smart port type
|
|
to revert to the default macro. "
|
|
::= { rlAutoSmartPortTypesEntry 4 }
|
|
|
|
rlAutoSmartPortTypesRevertToDefaultParams OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will cause the default smart port type parameter values associated with the built-in macro
|
|
of this smart port type to revert to their default values."
|
|
::= { rlAutoSmartPortTypesEntry 5 }
|
|
|
|
rlAutoSmartPortTypesBuiltinMacro OBJECT-TYPE
|
|
SYNTAX SmartPortMacroType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the macro is built-in or user defined."
|
|
::= { rlAutoSmartPortTypesEntry 6 }
|
|
|
|
|
|
rlAutoSmartPortMacrosParamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlAutoSmartPortMacrosParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table is used to keep all the default parameter values related to a specific port type."
|
|
::= { rlPortEvents 7 }
|
|
|
|
rlAutoSmartPortMacrosParamEntry OBJECT-TYPE
|
|
SYNTAX RlAutoSmartPortMacrosParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A parameter name & default value pair for a smart port type macro."
|
|
INDEX { rlAutoSmartPortTypesType, rlAutoSmartPortMacroType, IMPLIED rlAutoSmartPortMacrosParamName }
|
|
::= { rlAutoSmartPortMacrosParamTable 1 }
|
|
|
|
RlAutoSmartPortMacrosParamEntry ::= SEQUENCE {
|
|
rlAutoSmartPortMacroType SmartPortMacroType,
|
|
rlAutoSmartPortMacrosParamName SmartPortMacroParameterName,
|
|
rlAutoSmartPortMacrosParamOrder SmartPortMacroParameterOrder,
|
|
rlAutoSmartPortMacrosParamValue SmartPortMacroParameterValue
|
|
|
|
}
|
|
|
|
rlAutoSmartPortMacroType OBJECT-TYPE
|
|
SYNTAX SmartPortMacroType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Macro type - built-in or user defined."
|
|
::= { rlAutoSmartPortMacrosParamEntry 1 }
|
|
|
|
rlAutoSmartPortMacrosParamName OBJECT-TYPE
|
|
SYNTAX SmartPortMacroParameterName
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the parameter to be supplied at smart port macro activation. "
|
|
::= { rlAutoSmartPortMacrosParamEntry 2 }
|
|
|
|
rlAutoSmartPortMacrosParamOrder OBJECT-TYPE
|
|
SYNTAX SmartPortMacroParameterOrder
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to 'first' instructs the system to erase all previous information associated
|
|
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row.
|
|
Setting this object to 'middle' instructs the system to wait for further parameters.
|
|
Setting this object to 'last' informs the system that no further parameters will be sent and
|
|
therefore it can start the macro or builtin parameters change process.
|
|
Setting this object to 'single' instructs the system to erase all previous information associated
|
|
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row and
|
|
informs the system that no further parameters will be sent and therefore it can start macro or builtin
|
|
parameters change process."
|
|
::= { rlAutoSmartPortMacrosParamEntry 3 }
|
|
|
|
|
|
rlAutoSmartPortMacrosParamValue OBJECT-TYPE
|
|
SYNTAX SmartPortMacroParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default value of the parameter to be supplied at smart port macro activation. "
|
|
::= { rlAutoSmartPortMacrosParamEntry 4 }
|
|
|
|
|
|
|
|
rlAutoSmartPortPortsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlAutoSmartPortPortsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table is used to keep all the auto smart port information related to a specific port."
|
|
::= { rlPortEvents 8 }
|
|
|
|
rlAutoSmartPortPortsEntry OBJECT-TYPE
|
|
SYNTAX RlAutoSmartPortPortsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the rlAutoSmartPortPortsTable."
|
|
INDEX { rlAutoSmartPortPort }
|
|
::= { rlAutoSmartPortPortsTable 1 }
|
|
|
|
RlAutoSmartPortPortsEntry ::= SEQUENCE {
|
|
rlAutoSmartPortPort InterfaceIndex,
|
|
rlAutoSmartPortPortStatus INTEGER,
|
|
rlAutoSmartPortPortType SmartPortType,
|
|
rlAutoSmartPortPersistency INTEGER,
|
|
rlAutoSmartPortLearntPortType SmartPortType,
|
|
rlAutoSmartPortPortAcquiringType INTEGER,
|
|
rlAutoSmartPortLastActivatedMacro RlSmartPortsMacroNameOrZero,
|
|
rlAutoSmartPortFailedCommandNumber INTEGER,
|
|
rlAutoSmartPortSetLearntPortType TruthValue
|
|
|
|
|
|
}
|
|
|
|
rlAutoSmartPortPort OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port to which the smartport information is associated."
|
|
::= { rlAutoSmartPortPortsEntry 1 }
|
|
|
|
rlAutoSmartPortPortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {enabled(1), disabled(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether auto smart port feature is enabled or not on this port."
|
|
DEFVAL { enabled }
|
|
::= { rlAutoSmartPortPortsEntry 2 }
|
|
|
|
rlAutoSmartPortPortType OBJECT-TYPE
|
|
SYNTAX SmartPortType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Smart port type associated with this port. If set by user, the port will retain
|
|
the smart port type at link down, link not present and reboot events."
|
|
DEFVAL { default }
|
|
::= { rlAutoSmartPortPortsEntry 3 }
|
|
|
|
|
|
rlAutoSmartPortPersistency OBJECT-TYPE
|
|
SYNTAX INTEGER {persistent(1), not-persistent(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If set to persistent then, if the system concludes, according to
|
|
the information learnt there is no relevant device connected to the port,
|
|
the rlAutoSmartPortPortType will not be changed (as if the user set this
|
|
rlAutoSmartPortPortType himself), except on learning another rlAutoSmartPortPortType."
|
|
DEFVAL { not-persistent }
|
|
::= { rlAutoSmartPortPortsEntry 4 }
|
|
|
|
|
|
rlAutoSmartPortLearntPortType OBJECT-TYPE
|
|
SYNTAX SmartPortType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Smart port type learnt via the learning protocols. This value will
|
|
be different from rlAutoSmartPortPortType only if rlAutoSmartPortPortType
|
|
was manually configured (i.e. if the value of
|
|
rlAutoSmartPortPortAcquiringType is 'configuration'). The value of the object
|
|
is used to set the value of rlAutoSmartPortPortType
|
|
if the user removes the configuration."
|
|
DEFVAL { default }
|
|
::= { rlAutoSmartPortPortsEntry 5 }
|
|
|
|
rlAutoSmartPortPortAcquiringType OBJECT-TYPE
|
|
SYNTAX INTEGER {default(1), configuration(2), persistency(3), learning(4)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the way that the value of rlAutoSmartPortPortType was acquired. This object can be
|
|
set only during configuration download."
|
|
::= { rlAutoSmartPortPortsEntry 6 }
|
|
|
|
rlAutoSmartPortLastActivatedMacro OBJECT-TYPE
|
|
SYNTAX RlSmartPortsMacroNameOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates macro name of last activated macro or 'no macro' if no macro was run."
|
|
::= { rlAutoSmartPortPortsEntry 7 }
|
|
|
|
rlAutoSmartPortFailedCommandNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates number of command (starting with 1) that caused the macro
|
|
failure or 0 if the macro succeeded or no macro was run."
|
|
::= { rlAutoSmartPortPortsEntry 8 }
|
|
|
|
rlAutoSmartPortSetLearntPortType OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instructs the system to set the port type to the learnt port type."
|
|
::= { rlAutoSmartPortPortsEntry 9 }
|
|
|
|
rlAutoSmartPortParamsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlAutoSmartPortActionParamsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table optionally determines the parameter values for the macro that is activated when the smartport type is
|
|
manually changed for a specific port or trunk via the rlAutoSmartPortPortType object."
|
|
::= { rlPortEvents 9 }
|
|
|
|
rlAutoSmartPortParamsEntry OBJECT-TYPE
|
|
SYNTAX RlAutoSmartPortActionParamsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A parameter name & immediate value."
|
|
INDEX { rlAutoSmartPortIfIndex, IMPLIED rlAutoSmartPortParamName }
|
|
::= { rlAutoSmartPortParamsTable 1 }
|
|
|
|
RlAutoSmartPortActionParamsEntry ::= SEQUENCE {
|
|
rlAutoSmartPortIfIndex InterfaceIndex,
|
|
rlAutoSmartPortParamName SmartPortMacroParameterName,
|
|
rlAutoSmartPortParamOrder SmartPortMacroParameterOrder,
|
|
rlAutoSmartPortParamValue SmartPortMacroParameterValue
|
|
|
|
}
|
|
|
|
rlAutoSmartPortIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port or trunk that this entry is associated with. "
|
|
::= { rlAutoSmartPortParamsEntry 1 }
|
|
|
|
rlAutoSmartPortParamName OBJECT-TYPE
|
|
SYNTAX SmartPortMacroParameterName
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the parameter whose value must be supplied at a smart port macro activation. "
|
|
::= { rlAutoSmartPortParamsEntry 2 }
|
|
|
|
rlAutoSmartPortParamOrder OBJECT-TYPE
|
|
SYNTAX SmartPortMacroParameterOrder
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to 'first' instructs the system to erase all previous information associated
|
|
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row.
|
|
Setting this object to 'middle' instructs the system to wait for further parameters.
|
|
Setting this object to 'last' informs the system that no further parameters will be sent and
|
|
therefore it can start applying the smartport type.
|
|
Setting this object to 'single' instructs the system to erase all previous information associated
|
|
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row and
|
|
informs the system that no further parameters will be sent and informs the system that no further parameters will be sent and
|
|
therefore it can start applying the smartport type."
|
|
::= { rlAutoSmartPortParamsEntry 3 }
|
|
|
|
rlAutoSmartPortParamValue OBJECT-TYPE
|
|
SYNTAX SmartPortMacroParameterValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of the parameter whose value must be supplied at a smart port macro activation. "
|
|
::= { rlAutoSmartPortParamsEntry 4 }
|
|
|
|
|
|
|
|
rlAutoSmartTrunkRefreshTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlAutoSmartTrunkRefreshEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object causes running the SmartPort macros of the
|
|
following types: router, switch and ap. This operation is called the trunk refresh operation."
|
|
::= { rlPortEvents 10 }
|
|
|
|
|
|
rlAutoSmartTrunkRefreshEntry OBJECT-TYPE
|
|
SYNTAX RlAutoSmartTrunkRefreshEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the rlAutoSmartTrunkRefreshTable."
|
|
INDEX { rlAutoSmartTrunkRefreshSmartPortType, rlAutoSmartTrunkRefreshIfIndex }
|
|
::= { rlAutoSmartTrunkRefreshTable 1 }
|
|
|
|
RlAutoSmartTrunkRefreshEntry ::= SEQUENCE {
|
|
rlAutoSmartTrunkRefreshSmartPortType INTEGER,
|
|
rlAutoSmartTrunkRefreshIfIndex InterfaceIndexOrZero,
|
|
rlAutoSmartTrunkRefreshRowStatus RowStatus
|
|
}
|
|
|
|
rlAutoSmartTrunkRefreshSmartPortType OBJECT-TYPE
|
|
SYNTAX INTEGER {default(1), switch(11), router(12), ap(13)}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If not default the trunk refresh operation will be carried out on all ports of this smart port type if
|
|
rlAutoSmartTrunkRefreshIfIndex is nonzero, or on the port specifed by rlAutoSmartTrunkRefreshIfIndex if it's type
|
|
matches the given this smart port type (if not matching a wrong-value error will be return).
|
|
If default the trunk refresh operation will be carried out on all ports of router, switch and ap smart port type if
|
|
rlAutoSmartTrunkRefreshIfIndex is nonzero, or on the port specifed by rlAutoSmartTrunkRefreshIfIndex."
|
|
::= { rlAutoSmartTrunkRefreshEntry 1 }
|
|
|
|
rlAutoSmartTrunkRefreshIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If 0 the trunk refresh operation will be carried out on all ports of the smart port type as specified in the
|
|
rlAutoSmartTrunkRefreshSmartPortType. If nonzero the trunk refresh operation will be carried out
|
|
on the specified port, if rlAutoSmartTrunkRefreshSmartPortType is default or matches the smart port type of
|
|
the specified port. Any other case will result in a wrong-value error."
|
|
::= { rlAutoSmartTrunkRefreshEntry 2 }
|
|
|
|
rlAutoSmartTrunkRefreshRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Since this an action table only createAndGo will be accepted and the conceptual row will vanish immediately
|
|
after the action execution."
|
|
::= { rlAutoSmartTrunkRefreshEntry 3 }
|
|
|
|
|
|
rlAutoSmartBusy OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true indicates that the autosmartports system is temporarily busy performing a multiport
|
|
operation and therefore can not service management requests for the time-being."
|
|
::= { rlPortEvents 11 }
|
|
|
|
|
|
|
|
END
|