- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
537 lines
13 KiB
Text
537 lines
13 KiB
Text
-- SNMP SMIV2 MIB
|
|
--
|
|
|
|
SAMLEXAMERICA-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,enterprises,
|
|
IpAddress ,Integer32 FROM SNMPv2-SMI
|
|
-- Gauge, TimeTicks FROM RFC1155-SMI
|
|
DisplayString FROM SNMPv2-TC
|
|
OBJECT-TYPE FROM RFC-1212
|
|
NOTIFICATION-TYPE FROM SNMPv2-SMI
|
|
-- TRAP-TYPE FROM RFC-1215
|
|
TEXTUAL-CONVENTION FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP ,
|
|
NOTIFICATION-GROUP FROM SNMPv2-CONF;
|
|
|
|
samlexamericaInfo MODULE-IDENTITY
|
|
LAST-UPDATED "201612240000Z"
|
|
ORGANIZATION "SAMLEX AMERICA"
|
|
CONTACT-INFO
|
|
"www.samlexamerica.com"
|
|
DESCRIPTION
|
|
"Samlex America Inc"
|
|
|
|
REVISION "201612240000Z"
|
|
DESCRIPTION
|
|
"SMIv2."
|
|
::= { samlexamerica 1 }
|
|
|
|
samlexamerica OBJECT IDENTIFIER ::= { enterprises 49075 }
|
|
|
|
trapNotifications OBJECT IDENTIFIER ::= { samlexamericaInfo 0 }
|
|
product OBJECT IDENTIFIER ::= { samlexamericaInfo 1 }
|
|
setup OBJECT IDENTIFIER ::= { samlexamericaInfo 2 }
|
|
telecom OBJECT IDENTIFIER ::= { samlexamericaInfo 3 }
|
|
|
|
output OBJECT IDENTIFIER ::= { telecom 1 }
|
|
input OBJECT IDENTIFIER ::= { telecom 2 }
|
|
status OBJECT IDENTIFIER ::= { telecom 3 }
|
|
ui OBJECT IDENTIFIER ::= { telecom 4 }
|
|
warningconfig OBJECT IDENTIFIER ::= { telecom 5 }
|
|
warning OBJECT IDENTIFIER ::= { telecom 6 }
|
|
|
|
|
|
model OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Product Name"
|
|
::= { product 1 }
|
|
|
|
version OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version string. e.g. 1.0"
|
|
::= { product 2 }
|
|
|
|
date OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Date of version"
|
|
::= { product 3 }
|
|
|
|
cfgVout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Config Vout, eg. 1200 = 120.0V"
|
|
::= { output 1 }
|
|
|
|
vout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inverter Output Voltage RMS eg. 1200 = 120.0V"
|
|
::= { output 2 }
|
|
|
|
iout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inverter Output Current RMS eg. 48 = 4.8A"
|
|
::= { output 3 }
|
|
|
|
|
|
power OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inverter Output Real Power eg. 9002 = 900.2W"
|
|
::= { output 4 }
|
|
|
|
cfgFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Config Output Frequency eg. 500 = 50.0Hz"
|
|
::= { output 5 }
|
|
|
|
frequency OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inverter Output Frequency eg. 500 = 50.0Hz"
|
|
::= { output 6 }
|
|
|
|
gridvout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Grid AC Output Voltage RMS eg. 1200 = 120.0V"
|
|
::= { output 7 }
|
|
|
|
gridiout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Grid AC Output Current RMS eg. 48 = 4.8A"
|
|
::= { output 8 }
|
|
|
|
|
|
gridpower OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Grid AC Output Real Power eg. 9002 = 900.2W"
|
|
::= { output 9 }
|
|
|
|
gridfrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Grid AC Output Frequency eg. 500 = 50.0Hz"
|
|
::= { output 10 }
|
|
|
|
|
|
vin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC Voltage In eg. 245 = 24.5V"
|
|
::= { input 1 }
|
|
|
|
ovp OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Over Voltage Protection eg. 245 = 24.5V"
|
|
::= { input 2 }
|
|
|
|
ovpRecovery OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Over Voltage Protection Recovery eg. 245 = 24.5V"
|
|
::= { input 3 }
|
|
|
|
uvp OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Under Voltage Protection eg. 245 = 24.5V"
|
|
::= { input 4 }
|
|
|
|
uvpRecovery OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Under Voltage Protection Recovery eg. 245 = 24.5V"
|
|
::= { input 5 }
|
|
|
|
ovAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Over Voltage Alarm eg. 245 = 24.5V"
|
|
::= { input 6 }
|
|
|
|
uvAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Under Voltage Alarm eg. 245 = 24.5V"
|
|
::= { input 7 }
|
|
|
|
fan OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"0 = off, 1 = on"
|
|
::= { status 1 }
|
|
|
|
inverterMode OBJECT-TYPE
|
|
SYNTAX INTEGER { off-Line(0), on-Line(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"0 = Off-Line, 1 = On-Line"
|
|
::= { status 2 }
|
|
|
|
transferType OBJECT-TYPE
|
|
SYNTAX INTEGER { synchronized(0), unsynchronized(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"0 = Synchronized, 1 = UnSynchronized"
|
|
::= { status 3 }
|
|
|
|
byPassRelay OBJECT-TYPE
|
|
SYNTAX INTEGER { grid(0), inverter(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"0 = Grid, 1 = Inverter"
|
|
::= { status 4 }
|
|
|
|
gridAC OBJECT-TYPE
|
|
SYNTAX INTEGER { not-exists(0), detect(1), present(2), sync(3), wont-sync(4) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"not-exists(0), detect(1), present(2), sync(3), wont-sync(4)"
|
|
::= { status 5 }
|
|
|
|
olProtection OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Overload Protection Percentage eg. 110 = 110%"
|
|
::= { status 6 }
|
|
|
|
syncFreq OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Overload Protection Percentage eg. 50 = 5.0Hz"
|
|
::= { status 7 }
|
|
|
|
tempDD OBJECT-TYPE
|
|
SYNTAX INTEGER (-128..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC to DC temperature eg. 25 = 25 C"
|
|
::= { status 8 }
|
|
|
|
tempDA OBJECT-TYPE
|
|
SYNTAX INTEGER (-128..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC to AC temperature eg. 25 = 25 C"
|
|
::= { status 9 }
|
|
|
|
lcdContrast OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LCD Contrast eg. 50 = 50%"
|
|
::= { ui 1 }
|
|
|
|
lcdAutoOff OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LCD Auto Off eg. 0 = Disabled, 120 = 120 seconds"
|
|
::= { ui 2 }
|
|
|
|
rs232Speed OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RS-232 Speed eg. 19200 = 19200bps"
|
|
::= { ui 3 }
|
|
|
|
usbVCOMSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"USB VCOM Speed eg. 19200 = 19200bps"
|
|
::= { ui 4 }
|
|
|
|
wcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Warning Config Table"
|
|
::= { warningconfig 1 }
|
|
|
|
wcEntry OBJECT-TYPE
|
|
SYNTAX WcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Single warning config entry containing info."
|
|
INDEX { wcIndex }
|
|
::= { wcTable 1 }
|
|
|
|
WcEntry ::=
|
|
SEQUENCE {
|
|
wcIndex
|
|
INTEGER,
|
|
wcFanFaultEnabled
|
|
INTEGER,
|
|
wcOVAEnabled
|
|
INTEGER,
|
|
wcUVAEnabled
|
|
INTEGER,
|
|
wcOverLoadEnabled
|
|
INTEGER,
|
|
wcOverTemperatureEnabled
|
|
INTEGER,
|
|
wcShortCircuitEnabled
|
|
INTEGER
|
|
}
|
|
|
|
wcIndex OBJECT-TYPE
|
|
SYNTAX INTEGER { buzzer(0), drycontact(1) }
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of warning config"
|
|
::= { wcEntry 1 }
|
|
|
|
wcFanFaultEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan Fault Enabled"
|
|
::= { wcEntry 2 }
|
|
|
|
wcOVAEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Over Alarm Enabled"
|
|
::= { wcEntry 3 }
|
|
|
|
wcUVAEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Under Voltage Alarm Enabled"
|
|
::= { wcEntry 4 }
|
|
|
|
wcOverLoadEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Overload Enabled"
|
|
::= { wcEntry 5 }
|
|
|
|
wcOverTemperatureEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Over Temperature Enabled"
|
|
::= { wcEntry 6 }
|
|
|
|
wcShortCircuitEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Short Circuit Enabled"
|
|
::= { wcEntry 7 }
|
|
|
|
warningFanFault OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(0), warning(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan Fault Warning"
|
|
::= { warning 1 }
|
|
|
|
warningOverVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(0), warning(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Over Voltage Alarm Warning"
|
|
::= { warning 2 }
|
|
|
|
warningUnderVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(0), warning(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Under Voltage Alarm Warning"
|
|
::= { warning 3 }
|
|
|
|
warningOverload OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(0), warning(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Overload Warning"
|
|
::= { warning 4 }
|
|
|
|
warningOverTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(0), warning(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Over Temperature Warning"
|
|
::= { warning 5 }
|
|
|
|
warningShortCircuit OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(0), warning(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Short Circuit Warning"
|
|
::= { warning 6 }
|
|
|
|
warningOverVoltageProtection OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(0), warning(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Over Voltage Protection Warning"
|
|
::= { warning 7 }
|
|
|
|
warningUnderVoltageProtection OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(0), warning(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Under Voltage Protection Warning"
|
|
::= { warning 8 }
|
|
|
|
|
|
trapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap table"
|
|
::= { setup 1 }
|
|
|
|
trapEntry OBJECT-TYPE
|
|
SYNTAX TrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Single trap entry containing trap receiver info."
|
|
INDEX { trapReceiverNumber }
|
|
::= { trapTable 1 }
|
|
|
|
TrapEntry ::=
|
|
SEQUENCE {
|
|
trapReceiverNumber
|
|
Integer32,
|
|
trapEnabled
|
|
Integer32,
|
|
trapReceiverIPAddress
|
|
IpAddress,
|
|
trapCommunity
|
|
DisplayString
|
|
}
|
|
|
|
trapReceiverNumber OBJECT-TYPE
|
|
SYNTAX Integer32(0.. 4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of trap receiver"
|
|
::= { trapEntry 1 }
|
|
|
|
trapEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { no(0),yes(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if this trap entry is enabled or not."
|
|
::= { trapEntry 2 }
|
|
|
|
trapReceiverIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap receiver IP address"
|
|
::= { trapEntry 3 }
|
|
|
|
trapCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..7))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap community to be used by agent to send trap"
|
|
::= { trapEntry 4 }
|
|
|
|
snmpTrap NOTIFICATION-TYPE
|
|
OBJECTS { warningFanFault, warningOverVoltageAlarm, warningUnderVoltageAlarm, warningOverload, warningOverTemperature, warningShortCircuit, warningOverVoltageProtection, warningUnderVoltageProtection }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SMIV2 Trap notification information for the SNMP Manager."
|
|
::= {trapNotifications 1}
|
|
|
|
END
|