- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
2150 lines
86 KiB
Text
2150 lines
86 KiB
Text
-- *****************************************************************
|
|
-- FDDI-SMT73-MIB.my : RFC 1512 FDDI MIB for SMT 7.3
|
|
--
|
|
-- October 31, Chifei Cheng
|
|
--
|
|
-- Copyright (c) 1994-1996 by cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
--
|
|
|
|
FDDI-SMT73-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Counter
|
|
FROM RFC1155-SMI
|
|
transmission
|
|
FROM RFC1213-MIB
|
|
OBJECT-TYPE
|
|
FROM RFC-1212;
|
|
|
|
-- This MIB module uses the extended OBJECT-TYPE macro as
|
|
-- defined in [7].
|
|
|
|
|
|
-- this is the FDDI MIB module
|
|
|
|
fddi OBJECT IDENTIFIER ::= { transmission 15 }
|
|
fddimib OBJECT IDENTIFIER ::= { fddi 73 }
|
|
|
|
|
|
-- textual conventions
|
|
|
|
FddiTimeNano ::= INTEGER (0..2147483647)
|
|
-- This data type specifies 1 nanosecond units as
|
|
-- an integer value.
|
|
--
|
|
-- NOTE: The encoding is normal integer representation, not
|
|
-- two's complement. Since this type is used for variables
|
|
-- which are encoded as TimerTwosComplement in the ANSI
|
|
-- specification, two operations need to be performed on such
|
|
-- variables to convert from ANSI form to SNMP form:
|
|
--
|
|
-- 1) Convert from two's complement to normal integer
|
|
-- representation
|
|
-- 2) Multiply by 80 to convert from 80 nsec to 1 nsec units
|
|
--
|
|
-- No resolution is lost. Moreover, the objects for which
|
|
-- this data type is used effectively do not lose any range
|
|
-- due to the lower maximum value since they do not require
|
|
-- the full range.
|
|
--
|
|
-- Example: If fddimibMACTReq had a value of 8 ms, it would
|
|
-- be stored in ANSI TimerTwosComplement format as 0xFFFE7960
|
|
-- [8 ms is 100000 in 80 nsec units, which is then converted
|
|
-- to two's complement] but be reported as 8000000 in SNMP
|
|
-- since it is encoded here as FddiTimeNano.
|
|
|
|
|
|
|
|
|
|
|
|
FddiTimeMilli ::= INTEGER (0..2147483647)
|
|
-- This data type is used for some FDDI timers. It specifies
|
|
-- time in 1 millisecond units, in normal integer
|
|
-- representation.
|
|
|
|
FddiResourceId ::= INTEGER (0..65535)
|
|
-- This data type is used to refer to an instance of a MAC,
|
|
-- PORT, or PATH Resource ID. Indexing begins
|
|
-- at 1. Zero is used to indicate the absence of a resource.
|
|
|
|
FddiSMTStationIdType ::= OCTET STRING (SIZE (8))
|
|
-- The unique identifier for the FDDI station. This is a
|
|
-- string of 8 octets, represented as X' yy yy xx xx xx xx
|
|
-- xx xx' with the low order 6 octet (xx) from a unique IEEE
|
|
-- assigned address. The high order two bits of the IEEE
|
|
-- address, the group address bit and the administration bit
|
|
-- (Universal/Local) bit should both be zero. The first two
|
|
-- octets, the yy octets, are implementor-defined.
|
|
--
|
|
-- The representation of the address portion of the station id
|
|
-- is in the IEEE (ANSI/IEEE P802.1A) canonical notation for
|
|
-- 48 bit addresses. The canonical form is a 6-octet string
|
|
-- where the first octet contains the first 8 bits of the
|
|
-- address, with the I/G(Individual/Group) address bit as the
|
|
-- least significant bit and the U/L (Universal/Local) bit
|
|
-- as the next more significant bit, and so on. Note that
|
|
-- addresses in the ANSI FDDI standard SMT frames are
|
|
-- represented in FDDI MAC order.
|
|
|
|
FddiMACLongAddressType ::= OCTET STRING (SIZE (6))
|
|
-- The representation of long MAC addresses as management
|
|
-- values is in the IEEE (ANSI/IEEE P802.1A) canonical
|
|
-- notation for 48 bit addresses. The canonical form is a
|
|
-- 6-octet string where the first octet contains the first 8
|
|
-- bits of the address, with the I/G (Individual/Group)
|
|
-- address bit as the least significant bit and the U/L
|
|
-- (Universal/Local) bit as the next more significant bit,
|
|
-- and so on. Note that the addresses in the SMT frames are
|
|
-- represented in FDDI MAC order.
|
|
|
|
|
|
-- groups in the FDDI MIB module
|
|
|
|
fddimibSMT OBJECT IDENTIFIER ::= { fddimib 1 }
|
|
|
|
fddimibMAC OBJECT IDENTIFIER ::= { fddimib 2 }
|
|
|
|
fddimibMACCounters OBJECT IDENTIFIER ::= { fddimib 3 }
|
|
|
|
|
|
|
|
|
|
|
|
fddimibPATH OBJECT IDENTIFIER ::= { fddimib 4 }
|
|
|
|
fddimibPORT OBJECT IDENTIFIER ::= { fddimib 5 }
|
|
|
|
|
|
-- the SMT group
|
|
-- Implementation of the SMT group is mandatory for all
|
|
-- systems which implement manageable FDDI subsystems.
|
|
|
|
fddimibSMTNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of SMT implementations (regardless of
|
|
their current state) on this network management
|
|
application entity. The value for this variable
|
|
must remain constant at least from one re-
|
|
initialization of the entity's network management
|
|
system to the next re-initialization."
|
|
::= { fddimibSMT 1 }
|
|
|
|
|
|
-- the SMT table
|
|
|
|
fddimibSMTTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FddimibSMTEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of SMT entries. The number of entries
|
|
shall not exceed the value of fddimibSMTNumber."
|
|
::= { fddimibSMT 2 }
|
|
|
|
fddimibSMTEntry OBJECT-TYPE
|
|
SYNTAX FddimibSMTEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An SMT entry containing information common to a
|
|
given SMT."
|
|
INDEX { fddimibSMTIndex }
|
|
::= { fddimibSMTTable 1 }
|
|
|
|
FddimibSMTEntry ::=
|
|
SEQUENCE {
|
|
fddimibSMTIndex
|
|
INTEGER,
|
|
fddimibSMTStationId
|
|
FddiSMTStationIdType,
|
|
fddimibSMTOpVersionId
|
|
INTEGER,
|
|
fddimibSMTHiVersionId
|
|
INTEGER,
|
|
fddimibSMTLoVersionId
|
|
INTEGER,
|
|
fddimibSMTUserData
|
|
OCTET STRING,
|
|
fddimibSMTMIBVersionId
|
|
INTEGER,
|
|
fddimibSMTMACCts
|
|
INTEGER,
|
|
fddimibSMTNonMasterCts
|
|
INTEGER,
|
|
fddimibSMTMasterCts
|
|
INTEGER,
|
|
fddimibSMTAvailablePaths
|
|
INTEGER,
|
|
fddimibSMTConfigCapabilities
|
|
INTEGER,
|
|
fddimibSMTConfigPolicy
|
|
INTEGER,
|
|
fddimibSMTConnectionPolicy
|
|
INTEGER,
|
|
fddimibSMTTNotify
|
|
INTEGER,
|
|
fddimibSMTStatRptPolicy
|
|
INTEGER,
|
|
fddimibSMTTraceMaxExpiration
|
|
FddiTimeMilli,
|
|
fddimibSMTBypassPresent
|
|
INTEGER,
|
|
fddimibSMTECMState
|
|
INTEGER,
|
|
fddimibSMTCFState
|
|
INTEGER,
|
|
fddimibSMTRemoteDisconnectFlag
|
|
INTEGER,
|
|
fddimibSMTStationStatus
|
|
INTEGER,
|
|
fddimibSMTPeerWrapFlag
|
|
INTEGER,
|
|
fddimibSMTTimeStamp
|
|
FddiTimeMilli,
|
|
fddimibSMTTransitionTimeStamp
|
|
FddiTimeMilli,
|
|
fddimibSMTStationAction
|
|
INTEGER
|
|
}
|
|
|
|
fddimibSMTIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each SMT. The value for each
|
|
SMT must remain constant at least from one re-
|
|
initialization of the entity's network management
|
|
system to the next re-initialization."
|
|
::= { fddimibSMTEntry 1 }
|
|
|
|
fddimibSMTStationId OBJECT-TYPE
|
|
SYNTAX FddiSMTStationIdType -- OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Used to uniquely identify an FDDI station."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 11 }"
|
|
::= { fddimibSMTEntry 2 }
|
|
|
|
fddimibSMTOpVersionId OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The version that this station is using for its
|
|
operation (refer to ANSI 7.1.2.2). The value of
|
|
this variable is 2 for this SMT revision."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 13 }"
|
|
::= { fddimibSMTEntry 3 }
|
|
|
|
fddimibSMTHiVersionId OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The highest version of SMT that this station
|
|
supports (refer to ANSI 7.1.2.2)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 14 }"
|
|
::= { fddimibSMTEntry 4 }
|
|
|
|
fddimibSMTLoVersionId OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The lowest version of SMT that this station
|
|
supports (refer to ANSI 7.1.2.2)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 15 }"
|
|
::= { fddimibSMTEntry 5 }
|
|
|
|
fddimibSMTUserData OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (32))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable contains 32 octets of user defined
|
|
information. The information shall be an ASCII
|
|
string."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 17 }"
|
|
::= { fddimibSMTEntry 6 }
|
|
|
|
fddimibSMTMIBVersionId OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The version of the FDDI MIB of this station. The
|
|
value of this variable is 1 for this SMT
|
|
revision."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 18 }"
|
|
::= { fddimibSMTEntry 7 }
|
|
|
|
fddimibSMTMACCts OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of MACs in this station or
|
|
concentrator."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 21 }"
|
|
::= { fddimibSMTEntry 8 }
|
|
|
|
fddimibSMTNonMasterCts OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is the number of A, B,
|
|
and S ports in this station or concentrator."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 22 }"
|
|
::= { fddimibSMTEntry 9 }
|
|
|
|
fddimibSMTMasterCts OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of M Ports in a node. If the node is
|
|
not a concentrator, the value of the variable is
|
|
zero."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 23 }"
|
|
::= { fddimibSMTEntry 10 }
|
|
|
|
fddimibSMTAvailablePaths OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value that indicates the PATH types available
|
|
in the station.
|
|
|
|
The value is a sum. This value initially takes
|
|
the value zero, then for each type of PATH that
|
|
this node has available, 2 raised to a power is
|
|
added to the sum. The powers are according to the
|
|
following table:
|
|
|
|
Path Power
|
|
Primary 0
|
|
Secondary 1
|
|
Local 2
|
|
|
|
For example, a station having Primary and Local
|
|
PATHs available would have a value of 5 (2**0 +
|
|
2**2)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 24 }"
|
|
::= { fddimibSMTEntry 11 }
|
|
|
|
fddimibSMTConfigCapabilities OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value that indicates the configuration
|
|
capabilities of a node. The 'Hold Available' bit
|
|
indicates the support of the optional Hold
|
|
Function, which is controlled by
|
|
fddiSMTConfigPolicy. The 'CF-Wrap-AB' bit
|
|
indicates that the station has the capability of
|
|
performing a wrap_ab (refer to ANSI SMT 9.7.2.2).
|
|
|
|
The value is a sum. This value initially takes
|
|
the value zero, then for each of the configuration
|
|
policies currently enforced on the node, 2 raised
|
|
to a power is added to the sum. The powers are
|
|
according to the following table:
|
|
|
|
Policy Power
|
|
holdAvailable 0
|
|
CF-Wrap-AB 1 "
|
|
REFERENCE
|
|
"ANSI { fddiSMT 25 }"
|
|
::= { fddimibSMTEntry 12 }
|
|
|
|
fddimibSMTConfigPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value that indicates the configuration policies
|
|
currently desired in a node. 'Hold' is one of the
|
|
terms used for the Hold Flag, an optional ECM flag
|
|
used to enable the optional Hold policy.
|
|
|
|
The value is a sum. This value initially takes
|
|
the value zero, then for each of the configuration
|
|
policies currently enforced on the node, 2 raised
|
|
to a power is added to the sum. The powers are
|
|
according to the following table:
|
|
|
|
Policy Power
|
|
configurationhold 0 "
|
|
REFERENCE
|
|
"ANSI { fddiSMT 26 }"
|
|
::= { fddimibSMTEntry 13 }
|
|
|
|
fddimibSMTConnectionPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER (32768..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value representing the connection policies in
|
|
effect in a node. A station sets the corresponding
|
|
bit for each of the connection types that it
|
|
rejects. The letter designations, X and Y, in the
|
|
'rejectX-Y' names have the following significance:
|
|
X represents the PC-Type of the local PORT and Y
|
|
represents the PC_Type of the adjacent PORT
|
|
(PC_Neighbor). The evaluation of Connection-
|
|
Policy (PC-Type, PC-Neighbor) is done to determine
|
|
the setting of T- Val(3) in the PC-Signalling
|
|
sequence (refer to ANSI 9.6.3). Note that Bit 15,
|
|
(rejectM-M), is always set and cannot be cleared.
|
|
|
|
The value is a sum. This value initially takes
|
|
the value zero, then for each of the connection
|
|
policies currently enforced on the node, 2 raised
|
|
to a power is added to the sum. The powers are
|
|
according to the following table:
|
|
|
|
Policy Power
|
|
rejectA-A 0
|
|
rejectA-B 1
|
|
rejectA-S 2
|
|
rejectA-M 3
|
|
rejectB-A 4
|
|
rejectB-B 5
|
|
rejectB-S 6
|
|
rejectB-M 7
|
|
rejectS-A 8
|
|
rejectS-B 9
|
|
rejectS-S 10
|
|
rejectS-M 11
|
|
rejectM-A 12
|
|
rejectM-B 13
|
|
rejectM-S 14
|
|
rejectM-M 15 "
|
|
REFERENCE
|
|
"ANSI { fddiSMT 27 }"
|
|
::= { fddimibSMTEntry 14 }
|
|
|
|
fddimibSMTTNotify OBJECT-TYPE
|
|
SYNTAX INTEGER (2..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The timer, expressed in seconds, used in the
|
|
Neighbor Notification protocol. It has a range of
|
|
2 seconds to 30 seconds, and its default value is
|
|
30 seconds (refer to ANSI SMT 8.2)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 29 }"
|
|
::= { fddimibSMTEntry 15 }
|
|
|
|
fddimibSMTStatRptPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If true, indicates that the node will generate
|
|
Status Reporting Frames for its implemented events
|
|
and conditions. It has an initial value of true.
|
|
This variable determines the value of the
|
|
SR_Enable Flag (refer to ANSI SMT 8.3.2.1)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 30 }"
|
|
::= { fddimibSMTEntry 16 }
|
|
|
|
fddimibSMTTraceMaxExpiration OBJECT-TYPE
|
|
SYNTAX FddiTimeMilli
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reference Trace_Max (refer to ANSI SMT
|
|
9.4.4.2.2)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 31 }"
|
|
::= { fddimibSMTEntry 17 }
|
|
|
|
fddimibSMTBypassPresent OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A flag indicating if the station has a bypass on
|
|
its AB port pair."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 34 }"
|
|
::= { fddimibSMTEntry 18 }
|
|
|
|
fddimibSMTECMState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ec0(1), -- Out
|
|
ec1(2), -- In
|
|
ec2(3), -- Trace
|
|
ec3(4), -- Leave
|
|
ec4(5), -- Path_Test
|
|
ec5(6), -- Insert
|
|
ec6(7), -- Check
|
|
ec7(8) -- Deinsert
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the current state of the ECM state
|
|
machine (refer to ANSI SMT 9.5.2)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 41 }"
|
|
::= { fddimibSMTEntry 19 }
|
|
|
|
fddimibSMTCFState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cf0(1), -- isolated
|
|
cf1(2), -- local_a
|
|
cf2(3), -- local_b
|
|
cf3(4), -- local_ab
|
|
cf4(5), -- local_s
|
|
cf5(6), -- wrap_a
|
|
cf6(7), -- wrap_b
|
|
cf7(8), -- wrap_ab
|
|
cf8(9), -- wrap_s
|
|
cf9(10), -- c_wrap_a
|
|
cf10(11), -- c_wrap_b
|
|
cf11(12), -- c_wrap_s
|
|
cf12(13) -- thru
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The attachment configuration for the station or
|
|
concentrator (refer to ANSI SMT 9.7.2.2)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 42 }"
|
|
::= { fddimibSMTEntry 20 }
|
|
|
|
fddimibSMTRemoteDisconnectFlag OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A flag indicating that the station was remotely
|
|
disconnected from the network as a result of
|
|
receiving an fddiSMTAction, disconnect (refer to
|
|
ANSI SMT 6.4.5.3) in a Parameter Management Frame.
|
|
A station requires a Connect Action to rejoin and
|
|
clear the flag (refer to ANSI SMT 6.4.5.2)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 44 }"
|
|
::= { fddimibSMTEntry 21 }
|
|
|
|
fddimibSMTStationStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { concatenated(1), separated(2), thru(3) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of the primary and secondary
|
|
paths within this station."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 45 }"
|
|
::= { fddimibSMTEntry 22 }
|
|
|
|
fddimibSMTPeerWrapFlag OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable assumes the value of the
|
|
PeerWrapFlag in CFM (refer to ANSI SMT
|
|
9.7.2.4.4)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 46 }"
|
|
::= { fddimibSMTEntry 23 }
|
|
|
|
fddimibSMTTimeStamp OBJECT-TYPE
|
|
SYNTAX FddiTimeMilli
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable assumes the value of TimeStamp
|
|
(refer to ANSI SMT 8.3.2.1)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 51 }"
|
|
::= { fddimibSMTEntry 24 }
|
|
|
|
fddimibSMTTransitionTimeStamp OBJECT-TYPE
|
|
SYNTAX FddiTimeMilli
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable assumes the value of
|
|
TransitionTimeStamp (refer to ANSI SMT 8.3.2.1)."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 52 }"
|
|
::= { fddimibSMTEntry 25 }
|
|
|
|
fddimibSMTStationAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1), -- none of the following
|
|
connect(2),
|
|
disconnect(3),
|
|
path-Test(4),
|
|
self-Test(5),
|
|
disable-a(6),
|
|
disable-b(7),
|
|
disable-m(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object, when read, always returns a value of
|
|
other(1). The behavior of setting this variable
|
|
to each of the acceptable values is as follows:
|
|
|
|
other(1): Results in an appropriate error.
|
|
connect(2): Generates a Connect signal to ECM
|
|
to begin a connection sequence. See ANSI
|
|
Ref 9.4.2.
|
|
disconnect(3): Generates a Disconnect signal
|
|
to ECM. see ANSI Ref 9.4.2.
|
|
path-Test(4): Initiates a station Path_Test.
|
|
The Path_Test variable (see ANSI Ref
|
|
9.4.1) is set to 'Testing'. The results
|
|
of this action are not specified in this
|
|
standard.
|
|
self-Test(5): Initiates a station Self_Test.
|
|
The results of this action are not
|
|
specified in this standard.
|
|
disable-a(6): Causes a PC_Disable on the A
|
|
port if the A port mode is peer.
|
|
disable-b(7): Causes a PC_Disable on the B
|
|
port if the B port mode is peer.
|
|
disable-m(8): Causes a PC_Disable on all M
|
|
ports.
|
|
|
|
Attempts to set this object to all other values
|
|
results in an appropriate error. The result of
|
|
setting this variable to path-Test(4) or self-
|
|
Test(5) is implementation-specific."
|
|
REFERENCE
|
|
"ANSI { fddiSMT 60 }"
|
|
::= { fddimibSMTEntry 26 }
|
|
|
|
|
|
-- the MAC group
|
|
-- Implementation of the MAC Group is mandatory for all
|
|
-- systems which implement manageable FDDI subsystems.
|
|
|
|
fddimibMACNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of MAC implementations (across
|
|
all SMTs) on this network management application
|
|
entity. The value for this variable must remain
|
|
constant at least from one re-initialization of
|
|
the entity's network management system to the next
|
|
re-initialization."
|
|
::= { fddimibMAC 1 }
|
|
|
|
|
|
-- the MAC table
|
|
|
|
fddimibMACTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FddimibMACEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of MAC entries. The number of entries
|
|
shall not exceed the value of fddimibMACNumber."
|
|
::= { fddimibMAC 2 }
|
|
|
|
fddimibMACEntry OBJECT-TYPE
|
|
SYNTAX FddimibMACEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A MAC entry containing information common to a
|
|
given MAC."
|
|
INDEX { fddimibMACSMTIndex, fddimibMACIndex }
|
|
::= { fddimibMACTable 1 }
|
|
|
|
FddimibMACEntry ::=
|
|
SEQUENCE {
|
|
fddimibMACSMTIndex
|
|
INTEGER,
|
|
fddimibMACIndex
|
|
INTEGER,
|
|
fddimibMACIfIndex
|
|
INTEGER,
|
|
fddimibMACFrameStatusFunctions
|
|
INTEGER,
|
|
fddimibMACTMaxCapability
|
|
FddiTimeNano,
|
|
fddimibMACTVXCapability
|
|
FddiTimeNano,
|
|
fddimibMACAvailablePaths
|
|
INTEGER,
|
|
fddimibMACCurrentPath
|
|
INTEGER,
|
|
fddimibMACUpstreamNbr
|
|
FddiMACLongAddressType,
|
|
fddimibMACDownstreamNbr
|
|
FddiMACLongAddressType,
|
|
fddimibMACOldUpstreamNbr
|
|
FddiMACLongAddressType,
|
|
fddimibMACOldDownstreamNbr
|
|
FddiMACLongAddressType,
|
|
fddimibMACDupAddressTest
|
|
INTEGER,
|
|
fddimibMACRequestedPaths
|
|
INTEGER,
|
|
fddimibMACDownstreamPORTType
|
|
INTEGER,
|
|
fddimibMACSMTAddress
|
|
FddiMACLongAddressType,
|
|
fddimibMACTReq
|
|
FddiTimeNano,
|
|
fddimibMACTNeg
|
|
FddiTimeNano,
|
|
fddimibMACTMax
|
|
FddiTimeNano,
|
|
fddimibMACTvxValue
|
|
FddiTimeNano,
|
|
fddimibMACFrameCts
|
|
Counter,
|
|
fddimibMACCopiedCts
|
|
Counter,
|
|
fddimibMACTransmitCts
|
|
Counter,
|
|
fddimibMACErrorCts
|
|
Counter,
|
|
fddimibMACLostCts
|
|
Counter,
|
|
fddimibMACFrameErrorThreshold
|
|
INTEGER,
|
|
fddimibMACFrameErrorRatio
|
|
INTEGER,
|
|
fddimibMACRMTState
|
|
INTEGER,
|
|
fddimibMACDaFlag
|
|
INTEGER,
|
|
fddimibMACUnaDaFlag
|
|
INTEGER,
|
|
fddimibMACFrameErrorFlag
|
|
INTEGER,
|
|
fddimibMACMAUnitdataAvailable
|
|
INTEGER,
|
|
fddimibMACHardwarePresent
|
|
INTEGER,
|
|
fddimibMACMAUnitdataEnable
|
|
INTEGER
|
|
}
|
|
|
|
|
|
fddimibMACSMTIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the SMT index associated with this
|
|
MAC."
|
|
::= { fddimibMACEntry 1 }
|
|
|
|
fddimibMACIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index variable for uniquely identifying the MAC
|
|
object instances, which is the same as the
|
|
corresponding resource index in SMT."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 34 }"
|
|
::= { fddimibMACEntry 2 }
|
|
|
|
fddimibMACIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the MIB-II ifIndex corresponding to
|
|
this MAC. If none is applicable, 0 is returned."
|
|
REFERENCE
|
|
"MIB-II"
|
|
::= { fddimibMACEntry 3 }
|
|
|
|
fddimibMACFrameStatusFunctions OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the MAC's optional Frame Status
|
|
processing functions.
|
|
|
|
The value is a sum. This value initially takes
|
|
the value zero, then for each function present, 2
|
|
raised to a power is added to the sum. The powers
|
|
are according to the following table:
|
|
|
|
function Power
|
|
fs-repeating 0
|
|
fs-setting 1
|
|
fs-clearing 2 "
|
|
REFERENCE
|
|
"ANSI { fddiMAC 11 }"
|
|
::= { fddimibMACEntry 4 }
|
|
|
|
fddimibMACTMaxCapability OBJECT-TYPE
|
|
SYNTAX FddiTimeNano
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the maximum time value of fddiMACTMax
|
|
that this MAC can support."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 13 }"
|
|
::= { fddimibMACEntry 5 }
|
|
|
|
fddimibMACTVXCapability OBJECT-TYPE
|
|
SYNTAX FddiTimeNano
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the maximum time value of
|
|
fddiMACTvxValue that this MAC can support."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 14 }"
|
|
::= { fddimibMACEntry 6 }
|
|
|
|
fddimibMACAvailablePaths OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the paths available for this MAC (refer
|
|
to ANSI SMT 9.7.7).
|
|
|
|
The value is a sum. This value initially takes
|
|
the value zero, then for each type of PATH that
|
|
this MAC has available, 2 raised to a power is
|
|
added to the sum. The powers are according to the
|
|
following table:
|
|
|
|
Path Power
|
|
Primary 0
|
|
Secondary 1
|
|
Local 2 "
|
|
REFERENCE
|
|
"ANSI { fddiMAC 22 }"
|
|
::= { fddimibMACEntry 7 }
|
|
|
|
fddimibMACCurrentPath OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
isolated(1),
|
|
local(2),
|
|
secondary(3),
|
|
primary(4),
|
|
concatenated(5),
|
|
thru(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Path into which this MAC is
|
|
currently inserted (refer to ANSI 9.7.7)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 23 }"
|
|
::= { fddimibMACEntry 8 }
|
|
|
|
fddimibMACUpstreamNbr OBJECT-TYPE
|
|
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MAC's upstream neighbor's long individual MAC
|
|
address. It has an initial value of the SMT-
|
|
Unknown-MAC Address and is only modified as
|
|
specified by the Neighbor Information Frame
|
|
protocol (refer to ANSI SMT 7.2.1 and 8.2)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 24 }"
|
|
::= { fddimibMACEntry 9 }
|
|
|
|
fddimibMACDownstreamNbr OBJECT-TYPE
|
|
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MAC's downstream neighbor's long individual
|
|
MAC address. It has an initial value of the SMT-
|
|
Unknown-MAC Address and is only modified as
|
|
specified by the Neighbor Information Frame
|
|
protocol (refer to ANSI SMT 7.2.1 and 8.2)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 25 }"
|
|
::= { fddimibMACEntry 10 }
|
|
|
|
fddimibMACOldUpstreamNbr OBJECT-TYPE
|
|
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The previous value of the MAC's upstream
|
|
neighbor's long individual MAC address. It has an
|
|
initial value of the SMT-Unknown- MAC Address and
|
|
is only modified as specified by the Neighbor
|
|
Information Frame protocol (refer to ANSI SMT
|
|
7.2.1 and 8.2)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 26 }"
|
|
::= { fddimibMACEntry 11 }
|
|
|
|
fddimibMACOldDownstreamNbr OBJECT-TYPE
|
|
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The previous value of the MAC's downstream
|
|
neighbor's long individual MAC address. It has an
|
|
initial value of the SMT- Unknown-MAC Address and
|
|
is only modified as specified by the Neighbor
|
|
Information Frame protocol (refer to ANSI SMT
|
|
7.2.1 and 8.2)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 27 }"
|
|
::= { fddimibMACEntry 12 }
|
|
|
|
fddimibMACDupAddressTest OBJECT-TYPE
|
|
SYNTAX INTEGER { none(1), pass(2), fail(3) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Duplicate Address Test flag, Dup_Addr_Test
|
|
(refer to ANSI 8.2)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 29 }"
|
|
::= { fddimibMACEntry 13 }
|
|
|
|
fddimibMACRequestedPaths OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of permitted Paths which specifies the
|
|
Path(s) into which the MAC may be inserted (refer
|
|
to ansi SMT 9.7).
|
|
|
|
The value is a sum which represents the individual
|
|
paths that are desired. This value initially
|
|
takes the value zero, then for each type of PATH
|
|
that this node is, 2 raised to a power is added to
|
|
the sum. The powers are according to the
|
|
following table:
|
|
|
|
Path Power
|
|
local 0
|
|
secondary-alternate 1
|
|
primary-alternate 2
|
|
concatenated-alternate 3
|
|
secondary-preferred 4
|
|
primary-preferred 5
|
|
concatenated-preferred 6
|
|
thru 7 "
|
|
REFERENCE
|
|
"ANSI { fddiMAC 32 }"
|
|
::= { fddimibMACEntry 14 }
|
|
|
|
fddimibMACDownstreamPORTType OBJECT-TYPE
|
|
SYNTAX INTEGER { a(1), b(2), s(3), m(4), none(5) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the PC-Type of the first port that is
|
|
downstream of this MAC (the exit port)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 33 }"
|
|
::= { fddimibMACEntry 15 }
|
|
|
|
fddimibMACSMTAddress OBJECT-TYPE
|
|
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The 48-bit individual address of the MAC used for
|
|
SMT frames."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 41 }"
|
|
::= { fddimibMACEntry 16 }
|
|
|
|
fddimibMACTReq OBJECT-TYPE
|
|
SYNTAX FddiTimeNano
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is the T_Req_value passed to the
|
|
MAC. Without having detected a duplicate, the
|
|
time value of this variable shall assume the
|
|
maximum supported time value which is less than or
|
|
equal to the time value of fddiPATHMaxT-Req. When
|
|
a MAC has an address detected as a duplicate, it
|
|
may use a time value for this variable greater
|
|
than the time value of fddiPATHTMaxLowerBound. A
|
|
station shall cause claim when the new T_Req may
|
|
cause the value of T_Neg to change in the claim
|
|
process, (i.e., time value new T_Req < T_Neg, or
|
|
old T_Req = T_Neg)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 51 }"
|
|
::= { fddimibMACEntry 17 }
|
|
|
|
fddimibMACTNeg OBJECT-TYPE
|
|
SYNTAX FddiTimeNano
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is reported as a FddiTimeNano number."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 52 }"
|
|
::= { fddimibMACEntry 18 }
|
|
|
|
fddimibMACTMax OBJECT-TYPE
|
|
SYNTAX FddiTimeNano
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is the T_Max_value passed to the
|
|
MAC. The time value of this variable shall assume
|
|
the minimum supported time value which is greater
|
|
than or equal to the time value of fddiPATHT-
|
|
MaxLowerBound"
|
|
REFERENCE
|
|
"ANSI { fddiMAC 53 }"
|
|
::= { fddimibMACEntry 19 }
|
|
|
|
fddimibMACTvxValue OBJECT-TYPE
|
|
SYNTAX FddiTimeNano
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is the TVX_value passed to the MAC.
|
|
The time value of this variable shall assume the
|
|
minimum supported time value which is greater than
|
|
or equal to the time value of
|
|
fddiPATHTVXLowerBound."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 54 }"
|
|
::= { fddimibMACEntry 20 }
|
|
|
|
fddimibMACFrameCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count of the number of frames received by this
|
|
MAC (refer to ANSI MAC 7.5.1)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 71 }"
|
|
::= { fddimibMACEntry 21 }
|
|
|
|
fddimibMACCopiedCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count that should as closely as possible match
|
|
the number of frames addressed to (A bit set) and
|
|
successfully copied into the station's receive
|
|
buffers (C bit set) by this MAC (refer to ANSI MAC
|
|
7.5). Note that this count does not include MAC
|
|
frames."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 72 }"
|
|
::= { fddimibMACEntry 22 }
|
|
|
|
fddimibMACTransmitCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count that should as closely as possible match
|
|
the number of frames transmitted by this MAC
|
|
(refer to ANSI MAC 7.5). Note that this count
|
|
does not include MAC frames."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 73 }"
|
|
::= { fddimibMACEntry 23 }
|
|
|
|
fddimibMACErrorCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count of the number of frames that were
|
|
detected in error by this MAC that had not been
|
|
detected in error by another MAC (refer to ANSI
|
|
MAC 7.5.2)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 81 }"
|
|
::= { fddimibMACEntry 24 }
|
|
|
|
fddimibMACLostCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count of the number of instances that this MAC
|
|
detected a format error during frame reception
|
|
such that the frame was stripped (refer to ANSI
|
|
MAC 7.5.3)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 82 }"
|
|
::= { fddimibMACEntry 25 }
|
|
|
|
fddimibMACFrameErrorThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold for determining when a MAC Condition
|
|
report (see ANSI 8.3.1.1) shall be generated.
|
|
Stations not supporting variable thresholds shall
|
|
have a value of 0 and a range of (0..0)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 95 }"
|
|
::= { fddimibMACEntry 26 }
|
|
|
|
fddimibMACFrameErrorRatio OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is the value of the ratio,
|
|
|
|
((delta fddiMACLostCts + delta fddiMACErrorCts) /
|
|
(delta fddiMACFrameCts + delta fddiMACLostCts ))
|
|
* 2**16 "
|
|
REFERENCE
|
|
"ANSI { fddiMAC 96 }"
|
|
::= { fddimibMACEntry 27 }
|
|
|
|
fddimibMACRMTState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rm0(1), -- Isolated
|
|
rm1(2), -- Non_Op
|
|
rm2(3), -- Ring_Op
|
|
rm3(4), -- Detect
|
|
rm4(5), -- Non_Op_Dup
|
|
rm5(6), -- Ring_Op_Dup
|
|
rm6(7), -- Directed
|
|
rm7(8) -- Trace
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the current state of the RMT State
|
|
Machine (refer to ANSI 10.3.2)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 111 }"
|
|
::= { fddimibMACEntry 28 }
|
|
|
|
fddimibMACDaFlag OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RMT flag Duplicate Address Flag, DA_Flag
|
|
(refer to ANSI 10.2.1.2)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 112 }"
|
|
::= { fddimibMACEntry 29 }
|
|
|
|
fddimibMACUnaDaFlag OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A flag, UNDA_Flag (refer to ANSI 8.2.2.1), set
|
|
when the upstream neighbor reports a duplicate
|
|
address condition. Cleared when the condition
|
|
clears."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 113 }"
|
|
::= { fddimibMACEntry 30 }
|
|
|
|
fddimibMACFrameErrorFlag OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the MAC Frame Error Condition is
|
|
present when set. Cleared when the condition
|
|
clears and on station initialization."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 114 }"
|
|
::= { fddimibMACEntry 31 }
|
|
|
|
fddimibMACMAUnitdataAvailable OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable shall take on the value of the
|
|
MAC_Avail flag defined in RMT."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 116 }"
|
|
::= { fddimibMACEntry 32 }
|
|
|
|
fddimibMACHardwarePresent OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable indicates the presence of
|
|
underlying hardware support for this MAC object.
|
|
If the value of this object is false(2), the
|
|
reporting of the objects in this entry may be
|
|
handled in an implementation-specific manner."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 117 }"
|
|
::= { fddimibMACEntry 33 }
|
|
|
|
fddimibMACMAUnitdataEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable determines the value of the
|
|
MA_UNITDATA_Enable flag in RMT. The default and
|
|
initial value of this flag is true(1)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 118 }"
|
|
::= { fddimibMACEntry 34 }
|
|
|
|
|
|
-- the Enhanced MAC Counters group
|
|
-- Implementation of this Group is optional, but systems
|
|
-- claiming support must implement all variables in this
|
|
-- group
|
|
|
|
|
|
-- the MAC Counters table
|
|
|
|
fddimibMACCountersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FddimibMACCountersEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of MAC Counters entries. The number of
|
|
entries shall not exceed the value of
|
|
fddimibMACNumber."
|
|
::= { fddimibMACCounters 1 }
|
|
|
|
fddimibMACCountersEntry OBJECT-TYPE
|
|
SYNTAX FddimibMACCountersEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A MAC Counters entry containing information
|
|
common to a given MAC."
|
|
INDEX { fddimibMACSMTIndex, fddimibMACIndex }
|
|
::= { fddimibMACCountersTable 1 }
|
|
|
|
FddimibMACCountersEntry ::=
|
|
SEQUENCE {
|
|
fddimibMACTokenCts
|
|
Counter,
|
|
fddimibMACTvxExpiredCts
|
|
Counter,
|
|
fddimibMACNotCopiedCts
|
|
Counter,
|
|
fddimibMACLateCts
|
|
Counter,
|
|
fddimibMACRingOpCts
|
|
Counter,
|
|
fddimibMACNotCopiedRatio
|
|
INTEGER,
|
|
fddimibMACNotCopiedFlag
|
|
INTEGER,
|
|
fddimibMACNotCopiedThreshold
|
|
INTEGER
|
|
}
|
|
|
|
fddimibMACTokenCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count that should as closely as possible match
|
|
the number of times the station has received a
|
|
token (total of non-restricted and restricted) on
|
|
this MAC (see ANSI MAC 7.4). This count is
|
|
valuable for determination of network load."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 74 }"
|
|
::= { fddimibMACCountersEntry 1 }
|
|
|
|
fddimibMACTvxExpiredCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count that should as closely as possible match
|
|
the number of times that TVX has expired."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 83 }"
|
|
::= { fddimibMACCountersEntry 2 }
|
|
|
|
fddimibMACNotCopiedCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count that should as closely as possible match
|
|
the number of frames that were addressed to this
|
|
MAC but were not copied into its receive buffers
|
|
(see ANSI MAC 7.5). For example, this might occur
|
|
due to local buffer congestion. Because of
|
|
implementation considerations, this count may not
|
|
match the actual number of frames not copied. It
|
|
is not a requirement that this count be exact.
|
|
Note that this count does not include MAC frames."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 84 }"
|
|
::= { fddimibMACCountersEntry 3 }
|
|
|
|
fddimibMACLateCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count that should as closely as possible match
|
|
the number of TRT expirations since this MAC was
|
|
reset or a token was received (refer to ANSI MAC
|
|
7.4.5)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 85 }"
|
|
::= { fddimibMACCountersEntry 4 }
|
|
|
|
fddimibMACRingOpCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of the number of times the ring has
|
|
entered the 'Ring_Operational' state from the
|
|
'Ring Not Operational' state. This count is
|
|
updated when a SM_MA_STATUS.Indication of a change
|
|
in the Ring_Operational status occurs (refer to
|
|
ANSI 6.1.4). Because of implementation
|
|
considerations, this count may be less than the
|
|
actual RingOp_Ct. It is not a requirement that
|
|
this count be exact."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 86 }"
|
|
::= { fddimibMACCountersEntry 5 }
|
|
|
|
fddimibMACNotCopiedRatio OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is the value of the ratio:
|
|
|
|
(delta fddiMACNotCopiedCts /
|
|
(delta fddiMACCopiedCts +
|
|
delta fddiMACNotCopiedCts )) * 2**16 "
|
|
REFERENCE
|
|
"ANSI { fddiMAC 105 }"
|
|
::= { fddimibMACCountersEntry 6 }
|
|
|
|
fddimibMACNotCopiedFlag OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates that the Not Copied condition is
|
|
present when read as true(1). Set to false(2)
|
|
when the condition clears and on station
|
|
initialization."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 115 }"
|
|
::= { fddimibMACCountersEntry 7 }
|
|
|
|
fddimibMACNotCopiedThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold for determining when a MAC condition
|
|
report shall be generated. Stations not
|
|
supporting variable thresholds shall have a value
|
|
of 0 and a range of (0..0)."
|
|
REFERENCE
|
|
"ANSI { fddiMAC 103 }"
|
|
::= { fddimibMACCountersEntry 8 }
|
|
|
|
|
|
-- the PATH group
|
|
-- Implementation of the PATH group is mandatory for all
|
|
-- systems which implement manageable FDDI subsystems.
|
|
|
|
fddimibPATHNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of PATHs possible (across all
|
|
SMTs) on this network management application
|
|
entity. The value for this variable must remain
|
|
constant at least from one re-initialization of
|
|
the entity's network management system to the next
|
|
re-initialization."
|
|
::= { fddimibPATH 1 }
|
|
|
|
|
|
-- the PATH table
|
|
|
|
fddimibPATHTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FddimibPATHEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of PATH entries. The number of entries
|
|
shall not exceed the value of fddimibPATHNumber."
|
|
::= { fddimibPATH 2 }
|
|
|
|
fddimibPATHEntry OBJECT-TYPE
|
|
SYNTAX FddimibPATHEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A PATH entry containing information common to a
|
|
given PATH."
|
|
INDEX { fddimibPATHSMTIndex, fddimibPATHIndex }
|
|
::= { fddimibPATHTable 1 }
|
|
|
|
FddimibPATHEntry ::=
|
|
SEQUENCE {
|
|
fddimibPATHSMTIndex
|
|
INTEGER,
|
|
fddimibPATHIndex
|
|
INTEGER,
|
|
fddimibPATHTVXLowerBound
|
|
FddiTimeNano,
|
|
fddimibPATHTMaxLowerBound
|
|
FddiTimeNano,
|
|
fddimibPATHMaxTReq
|
|
FddiTimeNano
|
|
}
|
|
|
|
fddimibPATHSMTIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the SMT index associated with this
|
|
PATH."
|
|
::= { fddimibPATHEntry 1 }
|
|
|
|
|
|
fddimibPATHIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index variable for uniquely identifying the
|
|
primary, secondary and local PATH object
|
|
instances. Local PATH object instances are
|
|
represented with integer values 3 to 255."
|
|
REFERENCE
|
|
"ANSI { fddiPATH 11 }"
|
|
::= { fddimibPATHEntry 2 }
|
|
|
|
fddimibPATHTVXLowerBound OBJECT-TYPE
|
|
SYNTAX FddiTimeNano
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the minimum time value of
|
|
fddiMACTvxValue that shall be used by any MAC that
|
|
is configured in this path. The operational value
|
|
of fddiMACTvxValue is managed by setting this
|
|
variable. This variable has the time value range
|
|
of:
|
|
|
|
0 < fddimibPATHTVXLowerBound < fddimibPATHMaxTReq
|
|
Changes to this variable shall either satisfy the
|
|
time value relationship:
|
|
|
|
fddimibPATHTVXLowerBound <=
|
|
fddimibMACTVXCapability
|
|
|
|
of each of the MACs currently on the path, or be
|
|
considered out of range. The initial value of
|
|
fddimibPATHTVXLowerBound shall be 2500 nsec (2.5
|
|
ms)."
|
|
REFERENCE
|
|
"ANSI { fddiPATH 21 }"
|
|
::= { fddimibPATHEntry 3 }
|
|
|
|
fddimibPATHTMaxLowerBound OBJECT-TYPE
|
|
SYNTAX FddiTimeNano
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the minimum time value of fddiMACTMax
|
|
that shall be used by any MAC that is configured
|
|
in this path. The operational value of
|
|
fddiMACTMax is managed by setting this variable.
|
|
This variable has the time value range of:
|
|
|
|
fddimibPATHMaxTReq <= fddimibPATHTMaxLowerBound
|
|
|
|
and an absolute time value range of:
|
|
|
|
10000nsec (10 msec) <= fddimibPATHTMaxLowerBound
|
|
|
|
Changes to this variable shall either satisfy the
|
|
time value relationship:
|
|
|
|
fddimibPATHTMaxLowerBound <
|
|
fddimibMACTMaxCapability
|
|
|
|
of each of the MACs currently on the path, or be
|
|
considered out of range. The initial value of
|
|
fddimibPATHTMaxLowerBound shall be 165000 nsec
|
|
(165 msec)."
|
|
REFERENCE
|
|
"ANSI { fddiPATH 22 }"
|
|
::= { fddimibPATHEntry 4 }
|
|
|
|
fddimibPATHMaxTReq OBJECT-TYPE
|
|
SYNTAX FddiTimeNano
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the maximum time value of fddiMACT-Req
|
|
that shall be used by any MAC that is configured
|
|
in this path. The operational value of fddiMACT-
|
|
Req is managed by setting this variable. This
|
|
variable has the time value range of:
|
|
|
|
fddimibPATHTVXLowerBound < fddimibPATHMaxTReq <=
|
|
fddimibPATHTMaxLowerBound.
|
|
|
|
The default value of fddimibPATHMaxTReq is 165000
|
|
nsec (165 msec)."
|
|
REFERENCE
|
|
"ANSI { fddiPATH 23 }"
|
|
::= { fddimibPATHEntry 5 }
|
|
|
|
|
|
-- the PATH Configuration table
|
|
|
|
fddimibPATHConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FddimibPATHConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Path configuration entries. This
|
|
table lists all the resources that may be in this
|
|
Path."
|
|
REFERENCE
|
|
"ANSI { fddiPATH 18 }"
|
|
::= { fddimibPATH 3 }
|
|
|
|
fddimibPATHConfigEntry OBJECT-TYPE
|
|
SYNTAX FddimibPATHConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A collection of objects containing information
|
|
for a given PATH Configuration entry."
|
|
INDEX { fddimibPATHConfigSMTIndex,
|
|
fddimibPATHConfigPATHIndex,
|
|
fddimibPATHConfigTokenOrder }
|
|
::= { fddimibPATHConfigTable 1 }
|
|
|
|
FddimibPATHConfigEntry ::=
|
|
SEQUENCE {
|
|
fddimibPATHConfigSMTIndex
|
|
INTEGER,
|
|
fddimibPATHConfigPATHIndex
|
|
INTEGER,
|
|
fddimibPATHConfigTokenOrder
|
|
INTEGER,
|
|
fddimibPATHConfigResourceType
|
|
INTEGER,
|
|
fddimibPATHConfigResourceIndex
|
|
INTEGER,
|
|
fddimibPATHConfigCurrentPath
|
|
INTEGER
|
|
}
|
|
|
|
fddimibPATHConfigSMTIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the SMT index associated with this
|
|
configuration entry."
|
|
::= { fddimibPATHConfigEntry 1 }
|
|
|
|
fddimibPATHConfigPATHIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the PATH resource index associated
|
|
with this configuration entry."
|
|
::= { fddimibPATHConfigEntry 2 }
|
|
|
|
fddimibPATHConfigTokenOrder OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An object associated with Token order for this
|
|
entry. Thus if the token passes resources a, b, c
|
|
and d, in that order, then the value of this
|
|
object for these resources would be 1, 2, 3 and 4
|
|
respectively."
|
|
::= { fddimibPATHConfigEntry 3 }
|
|
|
|
fddimibPATHConfigResourceType OBJECT-TYPE
|
|
SYNTAX INTEGER { mac(2), port(4) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of resource associated with this
|
|
configuration entry."
|
|
::= { fddimibPATHConfigEntry 4 }
|
|
|
|
fddimibPATHConfigResourceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the SMT resource index used to refer
|
|
to the instance of this MAC or Port resource."
|
|
::= { fddimibPATHConfigEntry 5 }
|
|
|
|
fddimibPATHConfigCurrentPath OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
isolated(1), local(2), secondary(3), primary(4),
|
|
concatenated(5), thru(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current insertion status for this resource on
|
|
this Path."
|
|
::= { fddimibPATHConfigEntry 6 }
|
|
|
|
|
|
-- the PORT group
|
|
-- Implementation of the PORT group is mandatory for all
|
|
-- systems which implement manageable FDDI subsystems.
|
|
|
|
fddimibPORTNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of PORT implementations (across
|
|
all SMTs) on this network management application
|
|
entity. The value for this variable must remain
|
|
constant at least from one re-initialization of
|
|
the entity's network management system to the next
|
|
re-initialization."
|
|
::= { fddimibPORT 1 }
|
|
|
|
|
|
-- the PORT table
|
|
|
|
fddimibPORTTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FddimibPORTEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of PORT entries. The number of entries
|
|
shall not exceed the value of fddimibPORTNumber."
|
|
::= { fddimibPORT 2 }
|
|
|
|
fddimibPORTEntry OBJECT-TYPE
|
|
SYNTAX FddimibPORTEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A PORT entry containing information common to a
|
|
given PORT."
|
|
INDEX { fddimibPORTSMTIndex, fddimibPORTIndex }
|
|
::= { fddimibPORTTable 1 }
|
|
|
|
FddimibPORTEntry ::=
|
|
SEQUENCE {
|
|
fddimibPORTSMTIndex
|
|
INTEGER,
|
|
fddimibPORTIndex
|
|
INTEGER,
|
|
fddimibPORTMyType
|
|
INTEGER,
|
|
fddimibPORTNeighborType
|
|
INTEGER,
|
|
fddimibPORTConnectionPolicies
|
|
INTEGER,
|
|
fddimibPORTMACIndicated
|
|
INTEGER,
|
|
fddimibPORTCurrentPath
|
|
INTEGER,
|
|
fddimibPORTRequestedPaths
|
|
OCTET STRING,
|
|
fddimibPORTMACPlacement
|
|
FddiResourceId,
|
|
fddimibPORTAvailablePaths
|
|
INTEGER,
|
|
fddimibPORTPMDClass
|
|
INTEGER,
|
|
fddimibPORTConnectionCapabilities
|
|
INTEGER,
|
|
fddimibPORTBSFlag
|
|
INTEGER,
|
|
fddimibPORTLCTFailCts
|
|
Counter,
|
|
fddimibPORTLerEstimate
|
|
INTEGER,
|
|
fddimibPORTLemRejectCts
|
|
Counter,
|
|
fddimibPORTLemCts
|
|
Counter,
|
|
fddimibPORTLerCutoff
|
|
INTEGER,
|
|
fddimibPORTLerAlarm
|
|
INTEGER,
|
|
fddimibPORTConnectState
|
|
INTEGER,
|
|
fddimibPORTPCMState
|
|
INTEGER,
|
|
fddimibPORTPCWithhold
|
|
INTEGER,
|
|
fddimibPORTLerFlag
|
|
INTEGER,
|
|
fddimibPORTHardwarePresent
|
|
INTEGER,
|
|
fddimibPORTAction
|
|
INTEGER
|
|
}
|
|
|
|
fddimibPORTSMTIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the SMT index associated with this
|
|
PORT."
|
|
::= { fddimibPORTEntry 1 }
|
|
|
|
fddimibPORTIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each PORT within a given SMT,
|
|
which is the same as the corresponding resource
|
|
index in SMT. The value for each PORT must remain
|
|
constant at least from one re-initialization of
|
|
the entity's network management system to the next
|
|
re-initialization."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 29 }"
|
|
::= { fddimibPORTEntry 2 }
|
|
|
|
fddimibPORTMyType OBJECT-TYPE
|
|
SYNTAX INTEGER { a(1), b(2), s(3), m(4), none(5) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the PORT's PC_Type (refer to ANSI
|
|
9.4.1, and 9.6.3.2)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 12 }"
|
|
::= { fddimibPORTEntry 3 }
|
|
|
|
fddimibPORTNeighborType OBJECT-TYPE
|
|
SYNTAX INTEGER { a(1), b(2), s(3), m(4), none(5) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the remote PORT as determined in PCM.
|
|
This variable has an initial value of none, and is
|
|
only modified in PC_RCode(3)_Actions (refer to
|
|
ANSI SMT 9.6.3.2)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 13 }"
|
|
::= { fddimibPORTEntry 4 }
|
|
|
|
fddimibPORTConnectionPolicies OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value representing the PORT's connection
|
|
policies desired in the node. The value of pc-
|
|
mac-lct is a term used in the PC_MAC_LCT Flag (see
|
|
9.4.3.2). The value of pc-mac-loop is a term used
|
|
in the PC_MAC_Loop Flag.
|
|
|
|
The value is a sum. This value initially takes
|
|
the value zero, then for each PORT policy, 2
|
|
raised to a power is added to the sum. The powers
|
|
are according to the following table:
|
|
|
|
Policy Power
|
|
pc-mac-lct 0
|
|
pc-mac-loop 1 "
|
|
REFERENCE
|
|
"ANSI { fddiPORT 14 }"
|
|
::= { fddimibPORTEntry 5 }
|
|
|
|
fddimibPORTMACIndicated OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tVal9FalseRVal9False(1),
|
|
tVal9FalseRVal9True(2),
|
|
tVal9TrueRVal9False(3),
|
|
tVal9TrueRVal9True(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The indications (T_Val(9), R_Val(9)) in PC-
|
|
Signalling, of the intent to place a MAC in the
|
|
output token path to a PORT (refer to ANSI SMT
|
|
9.6.3.2.)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 15 }"
|
|
::= { fddimibPORTEntry 6 }
|
|
|
|
fddimibPORTCurrentPath OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ce0(1), -- isolated
|
|
ce1(2), -- local
|
|
ce2(3), -- secondary
|
|
ce3(4), -- primary
|
|
ce4(5), -- concatenated
|
|
ce5(6) -- thru
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Path(s) into which this PORT is
|
|
currently inserted."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 16 }"
|
|
::= { fddimibPORTEntry 7 }
|
|
|
|
fddimibPORTRequestedPaths OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is a list of permitted Paths where
|
|
each list element defines the Port's permitted
|
|
Paths. The first octet corresponds to 'none', the
|
|
second octet to 'tree', and the third octet to
|
|
'peer'."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 17 }"
|
|
::= { fddimibPORTEntry 8 }
|
|
|
|
fddimibPORTMACPlacement OBJECT-TYPE
|
|
SYNTAX FddiResourceId -- INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the MAC, if any, whose transmit path
|
|
exits the station via this PORT. The value shall
|
|
be zero if there is no MAC associated with the
|
|
PORT. Otherwise, the MACIndex of the MAC will be
|
|
the value of the variable."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 18 }"
|
|
::= { fddimibPORTEntry 9 }
|
|
|
|
fddimibPORTAvailablePaths OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Paths which are available to this
|
|
Port. In the absence of faults, the A and B Ports
|
|
will always have both the Primary and Secondary
|
|
Paths available.
|
|
|
|
The value is a sum. This value initially takes
|
|
the value zero, then for each type of PATH that
|
|
this port has available, 2 raised to a power is
|
|
added to the sum. The powers are according to the
|
|
following table:
|
|
|
|
Path Power
|
|
Primary 0
|
|
Secondary 1
|
|
Local 2 "
|
|
REFERENCE
|
|
"ANSI { fddiPORT 19 }"
|
|
::= { fddimibPORTEntry 10 }
|
|
|
|
fddimibPORTPMDClass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
multimode(1),
|
|
single-mode1(2),
|
|
single-mode2(3),
|
|
sonet(4),
|
|
low-cost-fiber(5),
|
|
twisted-pair(6),
|
|
unknown(7),
|
|
unspecified(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable indicates the type of PMD entity
|
|
associated with this port."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 22 }"
|
|
::= { fddimibPORTEntry 11 }
|
|
|
|
fddimibPORTConnectionCapabilities OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value that indicates the connection
|
|
capabilities of the port. The pc-mac-lct bit
|
|
indicates that the station has the capability of
|
|
setting the PC_MAC_LCT Flag. The pc-mac-loop bit
|
|
indicates that the station has the capability of
|
|
setting the PC_MAC_Loop Flag (refer to ANSI
|
|
9.4.3.2).
|
|
|
|
The value is a sum. This value initially takes
|
|
the value zero, then for each capability that this
|
|
port has, 2 raised to a power is added to the sum.
|
|
The powers are according to the following table:
|
|
|
|
capability Power
|
|
pc-mac-lct 0
|
|
pc-mac-loop 1 "
|
|
REFERENCE
|
|
"ANSI { fddiPORT 23 }"
|
|
::= { fddimibPORTEntry 12 }
|
|
|
|
fddimibPORTBSFlag OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable assumes the value of the BS_Flag
|
|
(refer to ANSI SMT 9.4.3.3)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 33 }"
|
|
::= { fddimibPORTEntry 13 }
|
|
|
|
fddimibPORTLCTFailCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The count of the consecutive times the link
|
|
confidence test (LCT) has failed during connection
|
|
management (refer to ANSI 9.4.1)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 42 }"
|
|
::= { fddimibPORTEntry 14 }
|
|
|
|
fddimibPORTLerEstimate OBJECT-TYPE
|
|
SYNTAX INTEGER (4..15)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A long term average link error rate. It ranges
|
|
from 10**-4 to 10**-15 and is reported as the
|
|
absolute value of the base 10 logarithm (refer to
|
|
ANSI SMT 9.4.7.5.)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 51 }"
|
|
::= { fddimibPORTEntry 15 }
|
|
|
|
fddimibPORTLemRejectCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A link error monitoring count of the times that a
|
|
link has been rejected."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 52 }"
|
|
::= { fddimibPORTEntry 16 }
|
|
|
|
fddimibPORTLemCts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The aggregate link error monitor error count, set
|
|
to zero only on station initialization."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 53 }"
|
|
::= { fddimibPORTEntry 17 }
|
|
|
|
fddimibPORTLerCutoff OBJECT-TYPE
|
|
SYNTAX INTEGER (4..15)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The link error rate estimate at which a link
|
|
connection will be broken. It ranges from 10**-4
|
|
to 10**-15 and is reported as the absolute value
|
|
of the base 10 logarithm (default of 7)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 58 }"
|
|
::= { fddimibPORTEntry 18 }
|
|
|
|
fddimibPORTLerAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER (4..15)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The link error rate estimate at which a link
|
|
connection will generate an alarm. It ranges from
|
|
10**-4 to 10**-15 and is reported as the absolute
|
|
value of the base 10 logarithm of the estimate
|
|
(default of 8)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 59 }"
|
|
::= { fddimibPORTEntry 19 }
|
|
|
|
fddimibPORTConnectState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
connecting(2),
|
|
standby(3),
|
|
active(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An indication of the connect state of this PORT
|
|
and is equal to the value of Connect_State (refer
|
|
to ANSI 9.4.1)"
|
|
REFERENCE
|
|
"ANSI { fddiPORT 61 }"
|
|
::= { fddimibPORTEntry 20 }
|
|
|
|
fddimibPORTPCMState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pc0(1), -- Off
|
|
pc1(2), -- Break
|
|
pc2(3), -- Trace
|
|
pc3(4), -- Connect
|
|
pc4(5), -- Next
|
|
pc5(6), -- Signal
|
|
pc6(7), -- Join
|
|
pc7(8), -- Verify
|
|
pc8(9), -- Active
|
|
pc9(10) -- Maint
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of this Port's PCM state machine refer
|
|
to ANSI SMT 9.6.2)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 62 }"
|
|
::= { fddimibPORTEntry 21 }
|
|
|
|
fddimibPORTPCWithhold OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
m-m(2),
|
|
otherincompatible(3),
|
|
pathnotavailable(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of PC_Withhold (refer to ANSI SMT
|
|
9.4.1)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 63 }"
|
|
::= { fddimibPORTEntry 22 }
|
|
|
|
fddimibPORTLerFlag OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The condition becomes active when the value of
|
|
fddiPORTLerEstimate is less than or equal to
|
|
fddiPORTLerAlarm. This will be reported with the
|
|
Status Report Frames (SRF) (refer to ANSI SMT
|
|
7.2.7 and 8.3)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 64 }"
|
|
::= { fddimibPORTEntry 23 }
|
|
|
|
fddimibPORTHardwarePresent OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable indicates the presence of
|
|
underlying hardware support for this Port object.
|
|
If the value of this object is false(2), the
|
|
reporting of the objects in this entry may be
|
|
handled in an implementation-specific manner."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 65 }"
|
|
::= { fddimibPORTEntry 24 }
|
|
|
|
fddimibPORTAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1), -- none of the following
|
|
maintPORT(2),
|
|
enablePORT(3),
|
|
disablePORT(4),
|
|
startPORT(5),
|
|
stopPORT(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Causes a Control signal to be generated with a
|
|
control_action of 'Signal' and the 'variable'
|
|
parameter set with the appropriate value (i.e.,
|
|
PC_Maint, PC_Enable, PC_Disable, PC_Start, or
|
|
PC_Stop) (refer to ANSI 9.4.2)."
|
|
REFERENCE
|
|
"ANSI { fddiPORT 70 }"
|
|
::= { fddimibPORTEntry 25 }
|
|
|
|
|
|