- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
4046 lines
161 KiB
Text
4046 lines
161 KiB
Text
DOCS-IF-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
-- do not import BITS,
|
|
Unsigned32,
|
|
Integer32,
|
|
Counter32,
|
|
Counter64,
|
|
TimeTicks,
|
|
IpAddress,
|
|
transmission
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
MacAddress,
|
|
RowStatus,
|
|
TruthValue,
|
|
TimeInterval,
|
|
TimeStamp
|
|
FROM SNMPv2-TC
|
|
OBJECT-GROUP,
|
|
|
|
MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF
|
|
ifIndex, InterfaceIndexOrZero
|
|
FROM IF-MIB
|
|
InetAddressType,
|
|
InetAddress
|
|
FROM INET-ADDRESS-MIB
|
|
IANAifType
|
|
FROM IANAifType-MIB;
|
|
|
|
docsIfMib MODULE-IDENTITY
|
|
LAST-UPDATED "200212200000Z" -- December 20, 2002
|
|
ORGANIZATION "IETF IPCDN Working Group"
|
|
CONTACT-INFO
|
|
" David Raftus
|
|
Postal: Imedia Semiconductor
|
|
340 Terry Fox Drive, Suite 202
|
|
Ottawa Ontario
|
|
Canada
|
|
Phone: +1 613 592 1052 ext.222
|
|
E-mail: david.raftus@imedia.com
|
|
|
|
IETF IPCDN Working Group
|
|
General Discussion: ipcdn@ietf.org
|
|
Subscribe: http://www.ietf.org/mailman/listinfo/ipcdn
|
|
Archive: ftp://ftp.ietf.org/ietf-mail-archive/ipcdn
|
|
Co-chairs: Richard Woundy, RWoundy@broadband.att.com
|
|
Jean-Francois Mule, jf.mule@cablelabs.com"
|
|
DESCRIPTION
|
|
"This is the MIB Module for DOCSIS 2.0 compliant Radio
|
|
Frequency (RF) interfaces in Cable Modems (CM) and
|
|
Cable Modem Termination Systems (CMTS)."
|
|
REVISION "200212200000Z"
|
|
DESCRIPTION
|
|
"pre-RFC draft v5:
|
|
Modified by David Raftus to add channel utilization related objects,
|
|
upstream channel equalization related objects, a cmts upstream minislot
|
|
counter table, a cmts downstream byte counter table, 64 bit versions of
|
|
existing 32 bit docsIfSigQTable objects, and perform some editorial
|
|
adjustments.
|
|
pre-RFC draft v4:
|
|
Modified by David Raftus to fix docsIfUpChannelWidth range
|
|
in compliance statements to accommodate 6.4Mhz channel at
|
|
5.12 Msymbol/sec. Also adjusted description of
|
|
docsIfUpChannelStatus to use correct rowStatus terminology.
|
|
pre-RFC draft v3:
|
|
Modified by David Raftus to add new textual convention
|
|
describing upstream modulation status. Also clarified
|
|
some object descriptions, fixed error in
|
|
docsIfSignalQualityEntry, fixed upstreamTable compliance
|
|
statements.
|
|
pre-RFC draft v2:
|
|
Modified by David Raftus to add capability to adjust
|
|
and verify upstream channel parameters as a group.
|
|
Also adjusted syntax and clarified descriptions of
|
|
selected objects.
|
|
pre-RFC draft v1:
|
|
Modified by Aviv Goren and David Raftus to accommodate
|
|
Docsis 2.0 Advanced Phy capabilities, as well as to
|
|
incorporate objects from the docsIfExt mib.
|
|
Modified by Rich Woundy to use IPv6-friendly
|
|
address objects, to accommodate EuroDOCSIS, and
|
|
to correct the SYNTAX of various objects."
|
|
REVISION "199908190000Z"
|
|
DESCRIPTION
|
|
"Initial Version, published as RFC 2670.
|
|
Modified by Mike StJohns to fix problems identified by
|
|
the first pass of the MIB doctor. Of special note,
|
|
docsIfRangingResp and docsIfCmtsInsertionInterval were
|
|
obsoleted and replaced by other objects with the same
|
|
functionality, but more appropriate SYNTAX."
|
|
::= { transmission 127 }
|
|
|
|
|
|
|
|
-- Textual Conventions
|
|
|
|
TenthdBmV ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d-1"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This data type represents power levels that are normally
|
|
expressed in dBmV. Units are in tenths of a dBmV;
|
|
for example, 5.1 dBmV will be represented as 51."
|
|
SYNTAX Integer32
|
|
|
|
TenthdB ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d-1"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This data type represents power levels that are normally
|
|
expressed in dB. Units are in tenths of a dB;
|
|
for example, 5.1 dB will be represented as 51."
|
|
SYNTAX Integer32
|
|
|
|
DocsisVersion ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Indicates the DOCSIS version number."
|
|
SYNTAX INTEGER {
|
|
docsis10 (1),
|
|
docsis11 (2),
|
|
docsis20 (3)
|
|
}
|
|
|
|
DocsisQosVersion ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Indicates the quality of service level."
|
|
SYNTAX INTEGER {
|
|
docsis10 (1),
|
|
docsis11 (2)
|
|
}
|
|
|
|
DocsisUpstreamType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Indicates the DOCSIS Upstream Channel Type."
|
|
SYNTAX INTEGER {
|
|
unknown (0),
|
|
tdma (1),
|
|
atdma (2),
|
|
scdma (3),
|
|
tdmaAndAtdma (4)
|
|
}
|
|
|
|
DocsisUpstreamTypeStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Indicates the DOCSIS Upstream Channel Type Status.
|
|
The shared channel indicator type is not valid, since
|
|
this type is used to specifically identify PHY mode."
|
|
SYNTAX INTEGER {
|
|
unknown (0),
|
|
tdma (1),
|
|
atdma (2),
|
|
scdma (3)
|
|
}
|
|
|
|
|
|
docsIfMibObjects OBJECT IDENTIFIER ::= { docsIfMib 1 }
|
|
docsIfBaseObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 1 }
|
|
docsIfCmObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 2 }
|
|
docsIfCmtsObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 3 }
|
|
|
|
--
|
|
-- BASE GROUP
|
|
--
|
|
|
|
--
|
|
-- The following table is implemented on both the Cable Modem (CM)
|
|
-- and the Cable Modem Termination System (CMTS). This table is
|
|
-- read only for the CM.
|
|
--
|
|
|
|
|
|
docsIfDownstreamChannelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfDownstreamChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes the attributes of downstream
|
|
channels (frequency bands)."
|
|
REFERENCE
|
|
"Document [25] from References, Table 6-12 and Table 6-13."
|
|
::= { docsIfBaseObjects 1 }
|
|
|
|
docsIfDownstreamChannelEntry OBJECT-TYPE
|
|
SYNTAX DocsIfDownstreamChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry provides a list of attributes for a single
|
|
Downstream channel.
|
|
An entry in this table exists for each ifEntry with an
|
|
ifType of docsCableDownstream(128)."
|
|
INDEX { ifIndex }
|
|
::= { docsIfDownstreamChannelTable 1 }
|
|
|
|
DocsIfDownstreamChannelEntry ::= SEQUENCE {
|
|
docsIfDownChannelId Integer32,
|
|
docsIfDownChannelFrequency Integer32,
|
|
docsIfDownChannelWidth Integer32,
|
|
docsIfDownChannelModulation INTEGER,
|
|
docsIfDownChannelInterleave INTEGER,
|
|
docsIfDownChannelPower TenthdBmV,
|
|
docsIfDownChannelAnnex INTEGER
|
|
}
|
|
|
|
docsIfDownChannelId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Cable Modem Termination System (CMTS) identification
|
|
of the downstream channel within this particular MAC
|
|
interface. If the interface is down, the object returns
|
|
the most current value. If the downstream channel ID is
|
|
unknown, this object returns a value of 0."
|
|
::= { docsIfDownstreamChannelEntry 1 }
|
|
|
|
docsIfDownChannelFrequency OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1000000000)
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The center of the downstream frequency associated with
|
|
this channel. This object will return the current tuner
|
|
frequency. If a CMTS provides IF output, this object
|
|
will return 0, unless this CMTS is in control of the
|
|
final downstream RF frequency. See the associated
|
|
compliance object for a description of valid frequencies
|
|
that may be written to this object."
|
|
REFERENCE
|
|
"Document [25] from References, Tables 4-1, 6-14."
|
|
::= { docsIfDownstreamChannelEntry 2 }
|
|
|
|
docsIfDownChannelWidth OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16000000)
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bandwidth of this downstream channel. Most
|
|
implementations are expected to support a channel width
|
|
of 6 MHz (North America) and/or 8 MHz (Europe). See the
|
|
associated compliance object for a description of the
|
|
valid channel widths for this object."
|
|
REFERENCE
|
|
"Document [25] from References, Table 6-14."
|
|
::= { docsIfDownstreamChannelEntry 3 }
|
|
|
|
docsIfDownChannelModulation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
qam64(3),
|
|
qam256(4),
|
|
qam512(5),
|
|
qam1024(6),
|
|
qpsk(7),
|
|
qam16(8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The modulation type associated with this downstream
|
|
channel. If the interface is down, this object either
|
|
returns the configured value (CMTS), the most current
|
|
value (CM), or the value of unknown(1). See the
|
|
associated conformance object for write conditions and
|
|
limitations. See the reference for specifics on the
|
|
modulation profiles implied by qam64 and qam256."
|
|
REFERENCE
|
|
"Document [25] from References, Table 6-14."
|
|
::= { docsIfDownstreamChannelEntry 4 }
|
|
|
|
docsIfDownChannelInterleave OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
taps8Increment16(3),
|
|
taps16Increment8(4),
|
|
taps32Increment4(5),
|
|
taps64Increment2(6),
|
|
taps128Increment1(7),
|
|
taps12increment17(8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Forward Error Correction (FEC) interleaving used
|
|
for this downstream channel.
|
|
Values are defined as follows:
|
|
taps8Increment16(3): protection 5.9/4.1 usec,
|
|
latency .22/.15 msec
|
|
taps16Increment8(4): protection 12/8.2 usec,
|
|
latency .48/.33 msec
|
|
taps32Increment4(5): protection 24/16 usec,
|
|
latency .98/.68 msec
|
|
taps64Increment2(6): protection 47/33 usec,
|
|
latency 2/1.4 msec
|
|
taps128Increment1(7): protection 95/66 usec,
|
|
latency 4/2.8 msec
|
|
taps12increment17(8): protection 18/14 usec,
|
|
latency 0.43/0.32 msec
|
|
taps12increment17 is implemented in
|
|
conformance with EuroDOCSIS document
|
|
'Adapted MIB-definitions - and a
|
|
clarification for MPEG-related issues - for
|
|
EuroDOCSIS cable modem systems' by tComLabs
|
|
and should only be used for a EuroDOCSIS MAC
|
|
interface.
|
|
|
|
If the interface is down, this object either returns
|
|
the configured value (CMTS), the most current value (CM),
|
|
or the value of unknown(1).
|
|
The value of other(2) is returned if the interleave
|
|
is known but not defined in the above list.
|
|
See the associated conformance object for write
|
|
conditions and limitations. See the reference for the FEC
|
|
configuration described by the setting of this object."
|
|
REFERENCE
|
|
"Document [25] from References, Table 6-13."
|
|
::= { docsIfDownstreamChannelEntry 5 }
|
|
|
|
docsIfDownChannelPower OBJECT-TYPE
|
|
SYNTAX TenthdBmV
|
|
UNITS "dBmV"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At the CMTS, the operational transmit power. At the CM,
|
|
the received power level. May be set to zero at the CM
|
|
if power level measurement is not supported.
|
|
If the interface is down, this object either returns
|
|
the configured value (CMTS), the most current value (CM)
|
|
or the value of 0. See the associated conformance object
|
|
for write conditions and limitations. See the reference
|
|
for recommended and required power levels."
|
|
REFERENCE
|
|
"Document [25] from References,Table 6-15."
|
|
::= { docsIfDownstreamChannelEntry 6 }
|
|
|
|
docsIfDownChannelAnnex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
annexA(3),
|
|
annexB(4),
|
|
annexC(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object indicates the conformance of
|
|
the implementation to important regional cable standards.
|
|
annexA : Annex A from ITU-J83 is used.
|
|
annexB : Annex B from ITU-J83 is used.
|
|
annexC : Annex C from ITU-J83 is used.
|
|
AnnexB is used for DOCSIS implementations"
|
|
REFERENCE
|
|
"Document [28] from References, Section 2.2"
|
|
::= { docsIfDownstreamChannelEntry 7 }
|
|
|
|
--
|
|
-- The following table is implemented on both the CM and the CMTS.
|
|
-- For the CM, only attached channels appear in the table. For the
|
|
-- CM, this table is read only as well.
|
|
--
|
|
|
|
docsIfUpstreamChannelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfUpstreamChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes the attributes of attached upstream
|
|
channels."
|
|
::= { docsIfBaseObjects 2 }
|
|
|
|
docsIfUpstreamChannelEntry OBJECT-TYPE
|
|
SYNTAX DocsIfUpstreamChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of attributes for a single upstream channel. For
|
|
Docsis 2.0 CMTSs, an entry in this table exists for
|
|
each ifEntry with an ifType of docsCableUpstreamChannel (205).
|
|
For Docsis 1.x CM/CMTSs and Docsis 2.0 CMs, an entry in this table exists
|
|
for each ifEntry with an ifType of docsCableUpstreamInterface (129)."
|
|
INDEX { ifIndex }
|
|
::= { docsIfUpstreamChannelTable 1 }
|
|
|
|
DocsIfUpstreamChannelEntry ::= SEQUENCE {
|
|
docsIfUpChannelId Integer32,
|
|
docsIfUpChannelFrequency Integer32,
|
|
docsIfUpChannelWidth Integer32,
|
|
docsIfUpChannelModulationProfile Unsigned32,
|
|
docsIfUpChannelSlotSize Unsigned32,
|
|
docsIfUpChannelTxTimingOffset Unsigned32,
|
|
docsIfUpChannelRangingBackoffStart Integer32,
|
|
docsIfUpChannelRangingBackoffEnd Integer32,
|
|
docsIfUpChannelTxBackoffStart Integer32,
|
|
docsIfUpChannelTxBackoffEnd Integer32,
|
|
docsIfUpChannelScdmaActiveCodes Unsigned32,
|
|
docsIfUpChannelScdmaCodesPerSlot Integer32,
|
|
docsIfUpChannelScdmaFrameSize Unsigned32,
|
|
docsIfUpChannelScdmaHoppingSeed Unsigned32,
|
|
docsIfUpChannelType DocsisUpstreamType,
|
|
docsIfUpChannelCloneFrom InterfaceIndexOrZero,
|
|
docsIfUpChannelUpdate TruthValue,
|
|
docsIfUpChannelStatus RowStatus,
|
|
docsIfUpChannelPreEqEnable TruthValue
|
|
}
|
|
|
|
docsIfUpChannelId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CMTS identification of the upstream channel."
|
|
::= { docsIfUpstreamChannelEntry 1 }
|
|
|
|
docsIfUpChannelFrequency OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1000000000)
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The center of the frequency band associated with this
|
|
upstream interface. This object returns 0 if the frequency
|
|
is undefined or unknown. Minimum permitted upstream
|
|
frequency is 5,000,000 Hz for current technology. See
|
|
the associated conformance object for write conditions
|
|
and limitations."
|
|
REFERENCE
|
|
"Document [25] from References, Table 4-2."
|
|
::= { docsIfUpstreamChannelEntry 2 }
|
|
|
|
docsIfUpChannelWidth OBJECT-TYPE
|
|
SYNTAX Integer32 (0..64000000)
|
|
UNITS "hertz"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bandwidth of this upstream interface. This object
|
|
returns 0 if the interface width is undefined or unknown.
|
|
Minimum permitted interface width is 200,000 Hz currently.
|
|
See the associated conformance object for write conditions
|
|
and limitations."
|
|
REFERENCE
|
|
"Document [25] from References, Table 6-12."
|
|
::= { docsIfUpstreamChannelEntry 3 }
|
|
|
|
|
|
docsIfUpChannelModulationProfile OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry identical to the docsIfModIndex in the
|
|
docsIfCmtsModulationTable that describes this channel.
|
|
This channel is further instantiated there by a grouping
|
|
of interval usage codes which together fully describe the
|
|
channel modulation. This object returns 0 if the
|
|
docsIfCmtsModulationTable entry does not exist or
|
|
docsIfCmtsModulationTable is empty. See
|
|
the associated conformance object for write conditions
|
|
and limitations."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
::= { docsIfUpstreamChannelEntry 4 }
|
|
|
|
docsIfUpChannelSlotSize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to TDMA and ATDMA channel types only.
|
|
The number of 6.25 microsecond ticks in each upstream mini-
|
|
slot. Returns zero if the value is undefined, unknown or in
|
|
case of an SCDMA channel.
|
|
See the associated conformance object for write
|
|
conditions and limitations. "
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.1.2.4."
|
|
::= { docsIfUpstreamChannelEntry 5 }
|
|
|
|
docsIfUpChannelTxTimingOffset OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At the CM, a measure of the current round trip time obtained from the
|
|
ranging offset (initial ranging offset + ranging offset adjustments).
|
|
At the CMTS, the maximum of timing offset, among all the CMs that
|
|
are/were present on the channel, taking into account all ( initial +
|
|
periodic )timing offset corrections that were sent for each of the CMs.
|
|
Generally, these measurements are positive, but if the
|
|
measurements are negative, the value of this object is zero. Used for
|
|
timing of CM upstream transmissions to ensure synchronized arrivals at
|
|
the CMTS. Units are in terms of (6.25 microseconds/64)."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.18."
|
|
::= { docsIfUpstreamChannelEntry 6 }
|
|
|
|
docsIfUpChannelRangingBackoffStart OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The initial random backoff window to use when retrying
|
|
Ranging Requests. Expressed as a power of 2. A value of 16
|
|
at the CMTS indicates that a proprietary adaptive retry
|
|
mechanism is to be used. See the associated conformance
|
|
object for write conditions and limitations."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.4."
|
|
::= { docsIfUpstreamChannelEntry 7 }
|
|
|
|
docsIfUpChannelRangingBackoffEnd OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The final random backoff window to use when retrying
|
|
Ranging Requests. Expressed as a power of 2. A value of 16
|
|
at the CMTS indicates that a proprietary adaptive retry
|
|
mechanism is to be used. See the associated conformance
|
|
object for write conditions and limitations."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.4."
|
|
::= { docsIfUpstreamChannelEntry 8 }
|
|
|
|
docsIfUpChannelTxBackoffStart OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The initial random backoff window to use when retrying
|
|
transmissions. Expressed as a power of 2. A value of 16
|
|
at the CMTS indicates that a proprietary adaptive retry
|
|
mechanism is to be used. See the associated conformance
|
|
object for write conditions and limitations."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.4."
|
|
::= { docsIfUpstreamChannelEntry 9 }
|
|
|
|
docsIfUpChannelTxBackoffEnd OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The final random backoff window to use when retrying
|
|
transmissions. Expressed as a power of 2. A value of 16
|
|
at the CMTS indicates that a proprietary adaptive retry
|
|
mechanism is to be used. See the associated conformance
|
|
object for write conditions and limitations."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.4."
|
|
::= { docsIfUpstreamChannelEntry 10 }
|
|
|
|
docsIfUpChannelScdmaActiveCodes OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0 | 64..128)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable for SCDMA channel types only.
|
|
Number of active codes. Returns zero for
|
|
Non-SCDMA channel types. Note that legal
|
|
values from 64..128 MUST be non-prime."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.11.2.1."
|
|
::= { docsIfUpstreamChannelEntry 11 }
|
|
|
|
docsIfUpChannelScdmaCodesPerSlot OBJECT-TYPE
|
|
SYNTAX Integer32(0 | 2..32)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable for SCDMA channel types only.
|
|
The number of SCDMA codes per mini-slot.
|
|
Returns zero if the value is undefined, unknown or in
|
|
case of a TDMA or ATDMA channel."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.11.2.1."
|
|
::= { docsIfUpstreamChannelEntry 12 }
|
|
|
|
docsIfUpChannelScdmaFrameSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..32)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable for SCDMA channel types only.
|
|
SCDMA Frame size in units of spreading intervals.
|
|
This value returns zero for non SCDMA Profiles."
|
|
REFERENCE
|
|
" Document [25] from References, Section 6.2.12."
|
|
::= { docsIfUpstreamChannelEntry 13 }
|
|
|
|
docsIfUpChannelScdmaHoppingSeed OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..32767)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable for SCDMA channel types only.
|
|
15 bit seed used for code hopping sequence initialization.
|
|
Returns zero for non-SCDMA channel types."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.14.1."
|
|
::= { docsIfUpstreamChannelEntry 14 }
|
|
|
|
docsIfUpChannelType OBJECT-TYPE
|
|
SYNTAX DocsisUpstreamType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the Upstream channel type.
|
|
Given the channel type, other channel attributes can be checked
|
|
for value validity at the time of entry creation and update."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.1."
|
|
::= { docsIfUpstreamChannelEntry 15 }
|
|
|
|
docsIfUpChannelCloneFrom OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Intended for use when a temporary inactive upstream table row is
|
|
created for the purpose of manipulating SCDMA parameters for an
|
|
active row. Refer to the descriptions of docsIfUpChannelStatus
|
|
and docsIfUpChannelUpdate for details of this procedure.
|
|
This object contains the ifIndex value of the active upstream
|
|
row whose SCDMA parameters are to be adjusted.
|
|
Although this object was created to facilitate SCDMA parameter
|
|
adjustment, it may also be used at the vendor's discretion for
|
|
non-SCDMA parameter adjustment.
|
|
This object must contain a value of zero for active upstream rows."
|
|
::= { docsIfUpstreamChannelEntry 16 }
|
|
|
|
docsIfUpChannelUpdate OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to perform the transfer of adjusted SCDMA parameters from the
|
|
temporary upstream row to the active upstream row indicated by the
|
|
docsIfUpChannelCloneFrom object. The transfer is initiated through
|
|
an SNMP SET of TRUE to this object. The SNMP SET will fail with a
|
|
GEN_ERROR (snmpv1) or COMMIT_FAILED_ERROR (snmpv2c/v3) if the adjusted
|
|
SCDMA parameter values are not compatible with each other.
|
|
Although this object was created to facilitate SCDMA parameter
|
|
adjustment, it may also be used at the vendor's discretion for
|
|
non-SCDMA parameter adjustment.
|
|
An SNMP GET of this object always returns FALSE."
|
|
::= { docsIfUpstreamChannelEntry 17 }
|
|
|
|
|
|
docsIfUpChannelStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is generally intended to be used for the creation of
|
|
a temporary inactive upstream row for the purpose of adjusting
|
|
the SCDMA channel parameters of an active upstream row.
|
|
The recommended procedure is:
|
|
1) Create an inactive row through an SNMP SET using createAndWait(5).
|
|
Use an ifIndex value outside the operational range of the system.
|
|
2) Set the docsIfUpChannelCloneFrom field to the ifIndex value of
|
|
the active row whose SCDMA parameters require adjustment.
|
|
3) Adjust the SCDMA parameter values using the new temporary inactive
|
|
row.
|
|
4) Update the active row by setting object docsIfUpChannelUpdate to
|
|
TRUE. This SET will fail if the adjusted SCDMA parameters are not
|
|
compatible with each other.
|
|
5) Delete the temporary row through an SNMP SET using DELETE.
|
|
|
|
The following restrictions apply to this object:
|
|
1) This object must contain a value of active(1) for active rows.
|
|
2) Temporary inactive rows must be created using createAndWait(5).
|
|
3) The only possible status change of a row created using
|
|
createAndWait(5) (ie notInService(2)) is to destroy(6).
|
|
These temporary rows must never become active.
|
|
4) A status transition from active (1) to destroy (6) is not
|
|
permitted. Entries with docsIfUpChannelStatus set to active(1)
|
|
are logically linked to a physical interface, not temporarily
|
|
created to clone parameters. The Interface MIB (RFC 2863)
|
|
ifAdminStatus should be used to take an Upstream Channel offline.
|
|
|
|
Although this object was created to facilitate SCDMA parameter
|
|
adjustment, it may also be used at the vendor's discretion for
|
|
non-SCDMA parameter adjustment."
|
|
::= { docsIfUpstreamChannelEntry 18 }
|
|
|
|
|
|
docsIfUpChannelPreEqEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At the CMTS, used to enable or disable pre-equalization on the
|
|
upstream channel represented by this table instance.
|
|
At the CM, this object is read-only and reflects the status of
|
|
pre-equalization as represented in the RNG-RSP."
|
|
::= { docsIfUpstreamChannelEntry 19 }
|
|
|
|
|
|
|
|
|
|
-- The following table describes the attributes of each class of
|
|
-- service. The entries in this table are referenced from the
|
|
-- docsIfServiceEntries. They exist as a separate table in order to
|
|
-- reduce redundant information in docsIfServiceTable.
|
|
--
|
|
-- This table is implemented at both the CM and the CMTS.
|
|
-- The CM need only maintain entries for the classes of service
|
|
-- referenced by its docsIfServiceTable.
|
|
--
|
|
|
|
docsIfQosProfileTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfQosProfileEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the attributes for each class of service."
|
|
::= { docsIfBaseObjects 3 }
|
|
|
|
docsIfQosProfileEntry OBJECT-TYPE
|
|
SYNTAX DocsIfQosProfileEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the attributes for a single class of service.
|
|
|
|
If implemented as read-create in the Cable Modem
|
|
Termination System, creation of entries in this table is
|
|
controlled by the value of docsIfCmtsQosProfilePermissions.
|
|
|
|
If implemented as read-only, entries are created based
|
|
on information in REG-REQ MAC messages received from
|
|
Cable Modems (Cable Modem Termination System
|
|
implementation), or based on information extracted from
|
|
the TFTP option file (Cable Modem implementation).
|
|
In the Cable Modem Termination system, read-only entries
|
|
are removed if no longer referenced by
|
|
docsIfCmtsServiceTable.
|
|
|
|
An entry in this table must not be removed while it is
|
|
referenced by an entry in docsIfCmServiceTable (Cable Modem)
|
|
or docsIfCmtsServiceTable (Cable Modem Termination System).
|
|
|
|
An entry in this table should not be changeable while
|
|
it is referenced by an entry in docsIfCmtsServiceTable.
|
|
|
|
If this table is created automatically, there should only
|
|
be a single entry for each Class of Service. Multiple
|
|
entries with the same Class of Service parameters are not
|
|
recommended."
|
|
INDEX { docsIfQosProfIndex }
|
|
::= { docsIfQosProfileTable 1 }
|
|
|
|
DocsIfQosProfileEntry ::= SEQUENCE {
|
|
docsIfQosProfIndex Integer32,
|
|
docsIfQosProfPriority Integer32,
|
|
docsIfQosProfMaxUpBandwidth Integer32,
|
|
docsIfQosProfGuarUpBandwidth Integer32,
|
|
docsIfQosProfMaxDownBandwidth Integer32,
|
|
docsIfQosProfMaxTxBurst Integer32, -- Deprecated
|
|
docsIfQosProfBaselinePrivacy TruthValue,
|
|
docsIfQosProfStatus RowStatus,
|
|
docsIfQosProfMaxTransmitBurst Integer32
|
|
}
|
|
|
|
docsIfQosProfIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16383)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index value that uniquely identifies an entry
|
|
in the docsIfQosProfileTable."
|
|
::= { docsIfQosProfileEntry 1 }
|
|
|
|
docsIfQosProfPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A relative priority assigned to this service when
|
|
allocating bandwidth. Zero indicates lowest priority
|
|
and seven indicates highest priority.
|
|
Interpretation of priority is device-specific.
|
|
MUST NOT be changed while this row is active."
|
|
REFERENCE
|
|
"Document [25] from References, Appendix C.1.1.4."
|
|
DEFVAL { 0 }
|
|
::= { docsIfQosProfileEntry 2 }
|
|
|
|
docsIfQosProfMaxUpBandwidth OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100000000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum upstream bandwidth, in bits per second,
|
|
allowed for a service with this service class.
|
|
Zero if there is no restriction of upstream bandwidth.
|
|
MUST NOT be changed while this row is active."
|
|
REFERENCE
|
|
"Document [25] from References, Appendix C.1.1.4."
|
|
|
|
DEFVAL { 0 }
|
|
::= { docsIfQosProfileEntry 3 }
|
|
|
|
docsIfQosProfGuarUpBandwidth OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100000000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum guaranteed upstream bandwidth, in bits per second,
|
|
allowed for a service with this service class.
|
|
MUST NOT be changed while this row is active."
|
|
REFERENCE
|
|
"Document [25] from References, Appendix C.1.1.4."
|
|
DEFVAL { 0 }
|
|
::= { docsIfQosProfileEntry 4 }
|
|
|
|
docsIfQosProfMaxDownBandwidth OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100000000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum downstream bandwidth, in bits per second,
|
|
allowed for a service with this service class.
|
|
Zero if there is no restriction of downstream bandwidth.
|
|
MUST NOT be changed while this row is active."
|
|
REFERENCE
|
|
"Document [25] from References, Appendix C.1.1.4."
|
|
|
|
DEFVAL { 0 }
|
|
::= { docsIfQosProfileEntry 5 }
|
|
|
|
docsIfQosProfMaxTxBurst OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The maximum number of mini-slots that may be requested
|
|
for a single upstream transmission.
|
|
A value of zero means there is no limit.
|
|
MUST NOT be changed while this row is active.
|
|
This object has been deprecated and replaced by
|
|
docsIfQosProfMaxTransmitBurst, to fix a mismatch
|
|
of the units and value range with respect to the DOCSIS
|
|
Maximum Upstream Channel Transmit Burst Configuration
|
|
Setting."
|
|
REFERENCE
|
|
"Document [25] from References, C.1.1.4."
|
|
DEFVAL { 0 }
|
|
::= { docsIfQosProfileEntry 6 }
|
|
|
|
docsIfQosProfBaselinePrivacy OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether Baseline Privacy is enabled for this
|
|
service class.
|
|
MUST NOT be changed while this row is active."
|
|
DEFVAL { false }
|
|
::= { docsIfQosProfileEntry 7 }
|
|
|
|
docsIfQosProfStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is object is to used to create or delete rows in
|
|
this table. This object MUST NOT be changed from active
|
|
while the row is referenced by the any entry in either
|
|
docsIfCmServiceTable (on the CM), or the
|
|
docsIfCmtsServiceTable (on the CMTS)."
|
|
::= { docsIfQosProfileEntry 8 }
|
|
|
|
docsIfQosProfMaxTransmitBurst OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of bytes that may be requested for a
|
|
single upstream transmission. A value of zero means there
|
|
is no limit. Note: This value does not include any
|
|
physical layer overhead.
|
|
MUST NOT be changed while this row is active."
|
|
REFERENCE
|
|
"Document [25] from References, Appendix C.1.1.4."
|
|
DEFVAL { 0 }
|
|
::= { docsIfQosProfileEntry 9 }
|
|
|
|
docsIfSignalQualityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfSignalQualityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At the CM, describes the PHY signal quality of downstream
|
|
channels. At the CMTS, describes the PHY signal quality of
|
|
upstream channels. At the CMTS, this table may exclude
|
|
contention intervals."
|
|
::= { docsIfBaseObjects 4 }
|
|
|
|
docsIfSignalQualityEntry OBJECT-TYPE
|
|
SYNTAX DocsIfSignalQualityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At the CM, describes the PHY characteristics of a
|
|
downstream channel. At the CMTS, describes the PHY signal
|
|
quality of an upstream channel.
|
|
An entry in this table exists for each ifEntry with an
|
|
ifType of docsCableUpstreamChannel(205) for Cable Modem Termination
|
|
Systems and docsCableDownstream(128) for Cable Modems."
|
|
INDEX { ifIndex }
|
|
::= { docsIfSignalQualityTable 1 }
|
|
|
|
DocsIfSignalQualityEntry ::= SEQUENCE {
|
|
docsIfSigQIncludesContention TruthValue,
|
|
docsIfSigQUnerroreds Counter32,
|
|
docsIfSigQCorrecteds Counter32,
|
|
docsIfSigQUncorrectables Counter32,
|
|
docsIfSigQSignalNoise TenthdB,
|
|
docsIfSigQMicroreflections Integer32,
|
|
docsIfSigQEqualizationData OCTET STRING,
|
|
docsIfSigQExtUnerroreds Counter64,
|
|
docsIfSigQExtCorrecteds Counter64,
|
|
docsIfSigQExtUncorrectables Counter64
|
|
}
|
|
|
|
docsIfSigQIncludesContention OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"true(1) if this CMTS includes contention intervals in
|
|
the counters in this table. Always false(2) for CMs."
|
|
REFERENCE
|
|
"Document [25] from References,
|
|
Section 9.4.1"
|
|
::= { docsIfSignalQualityEntry 1 }
|
|
|
|
docsIfSigQUnerroreds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received on this channel without error.
|
|
This includes all codewords, whether or not they
|
|
were part of frames destined for this device."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfSignalQualityEntry 2 }
|
|
|
|
docsIfSigQCorrecteds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received on this channel with correctable
|
|
errors. This includes all codewords, whether or not
|
|
they were part of frames destined for this device."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfSignalQualityEntry 3 }
|
|
|
|
docsIfSigQUncorrectables OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received on this channel with uncorrectable
|
|
errors. This includes all codewords, whether or not
|
|
they were part of frames destined for this device."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfSignalQualityEntry 4 }
|
|
|
|
docsIfSigQSignalNoise OBJECT-TYPE
|
|
SYNTAX TenthdB
|
|
UNITS "dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signal/Noise ratio as perceived for this channel.
|
|
At the CM, describes the Signal/Noise of the downstream
|
|
channel. At the CMTS, describes the average Signal/Noise
|
|
of the upstream channel."
|
|
REFERENCE
|
|
"Document [25] from References, Tables 4-1 and 4-2"
|
|
::= { docsIfSignalQualityEntry 5 }
|
|
|
|
docsIfSigQMicroreflections OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
UNITS "dBc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total microreflections including in-channel response
|
|
as perceived on this interface, measured in dBc below
|
|
the signal level.
|
|
This object is not assumed to return an absolutely
|
|
accurate value, but should give a rough indication
|
|
of microreflections received on this interface.
|
|
It is up to the implementer to provide information
|
|
as accurate as possible."
|
|
REFERENCE
|
|
"Document [25] from References, Tables 4-1 and 4-2"
|
|
::= { docsIfSignalQualityEntry 6 }
|
|
|
|
docsIfSigQEqualizationData OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At the CM, returns the equalization data for the downstream
|
|
channel. At the CMTS, returns the average equalization
|
|
data for the upstream channel. Returns an empty string
|
|
if the value is unknown or if there is no equalization
|
|
data available or defined."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-21."
|
|
::= { docsIfSignalQualityEntry 7 }
|
|
|
|
docsIfSigQExtUnerroreds OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received on this channel without error.
|
|
This includes all codewords, whether or not they
|
|
were part of frames destined for this device.
|
|
This is the 64 bit version of docsIfSigQUnerroreds."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfSignalQualityEntry 8 }
|
|
|
|
docsIfSigQExtCorrecteds OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received on this channel with correctable
|
|
errors. This includes all codewords, whether or not
|
|
they were part of frames destined for this device.
|
|
This is the 64 bit version of docsIfSigQCorrecteds."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfSignalQualityEntry 9 }
|
|
|
|
docsIfSigQExtUncorrectables OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received on this channel with uncorrectable
|
|
errors. This includes all codewords, whether or not
|
|
they were part of frames destined for this device.
|
|
This is the 64 bit version of docsIfSigQUncorrectables."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfSignalQualityEntry 10 }
|
|
|
|
|
|
--
|
|
-- DOCSIS Version of the device
|
|
--
|
|
|
|
docsIfDocsisBaseCapability OBJECT-TYPE
|
|
SYNTAX DocsisVersion
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indication of the DOCSIS capability of the device.
|
|
This object mirrors docsIfDocsisCapability from the
|
|
DocsIfExt mib."
|
|
REFERENCE
|
|
"Document [25] from References, Annex G."
|
|
::= { docsIfBaseObjects 5 }
|
|
|
|
|
|
--
|
|
-- CABLE MODEM GROUP
|
|
--
|
|
|
|
-- #######
|
|
|
|
|
|
--
|
|
-- The CM MAC Table
|
|
--
|
|
|
|
docsIfCmMacTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmMacEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the attributes of each CM MAC interface,
|
|
extending the information available from ifEntry."
|
|
::= { docsIfCmObjects 1 }
|
|
|
|
docsIfCmMacEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmMacEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects describing attributes of
|
|
each MAC entry, extending the information in ifEntry.
|
|
An entry in this table exists for each ifEntry with an
|
|
ifType of docsCableMaclayer(127)."
|
|
INDEX { ifIndex }
|
|
::= { docsIfCmMacTable 1 }
|
|
|
|
DocsIfCmMacEntry ::= SEQUENCE {
|
|
docsIfCmCmtsAddress MacAddress,
|
|
docsIfCmCapabilities BITS,
|
|
docsIfCmRangingRespTimeout TimeTicks,
|
|
docsIfCmRangingTimeout TimeInterval
|
|
}
|
|
|
|
docsIfCmCmtsAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the CMTS that is believed to control this MAC
|
|
domain. At the CM, this will be the source address from
|
|
SYNC, MAP, and other MAC-layer messages. If the CMTS is
|
|
unknown, returns 00-00-00-00-00-00."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.2.2."
|
|
::= { docsIfCmMacEntry 1 }
|
|
|
|
docsIfCmCapabilities OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
atmCells(0),
|
|
concatenation(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the capabilities of the MAC implementation
|
|
at this interface. Note that packet transmission is
|
|
always supported. Therefore, there is no specific bit
|
|
required to explicitly indicate this capability.
|
|
Note that BITS objects are encoded most significant bit
|
|
first. For example, if bit 1 is set, the value of this
|
|
object is the octet string '40'H."
|
|
::= { docsIfCmMacEntry 2 }
|
|
|
|
|
|
-- This object has been obsoleted and replaced by
|
|
-- docsIfCmRangingTimeout to correct the typing to TimeInterval. New
|
|
-- implementations of the MIB should use docsIfCmRangingTimeout instead.
|
|
|
|
docsIfCmRangingRespTimeout OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Waiting time for a Ranging Response packet."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.1.6."
|
|
DEFVAL { 20 }
|
|
::= { docsIfCmMacEntry 3 }
|
|
|
|
docsIfCmRangingTimeout OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Waiting time for a Ranging Response packet."
|
|
REFERENCE
|
|
"Document [25] from References,
|
|
Section 9.1.6, timer T3."
|
|
DEFVAL { 20 }
|
|
::= { docsIfCmMacEntry 4 }
|
|
|
|
--
|
|
-- CM status table.
|
|
-- This table is implemented only at the CM.
|
|
--
|
|
|
|
docsIfCmStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table maintains a number of status objects
|
|
and counters for Cable Modems."
|
|
::= { docsIfCmObjects 2 }
|
|
|
|
docsIfCmStatusEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of status objects and counters for a single MAC
|
|
layer instance in a Cable Modem.
|
|
An entry in this table exists for each ifEntry with an
|
|
ifType of docsCableMaclayer(127)."
|
|
INDEX { ifIndex }
|
|
::= { docsIfCmStatusTable 1 }
|
|
|
|
DocsIfCmStatusEntry ::= SEQUENCE {
|
|
docsIfCmStatusValue INTEGER,
|
|
docsIfCmStatusCode OCTET STRING,
|
|
docsIfCmStatusTxPower TenthdBmV,
|
|
docsIfCmStatusResets Counter32,
|
|
docsIfCmStatusLostSyncs Counter32,
|
|
docsIfCmStatusInvalidMaps Counter32,
|
|
docsIfCmStatusInvalidUcds Counter32,
|
|
docsIfCmStatusInvalidRangingResponses Counter32,
|
|
docsIfCmStatusInvalidRegistrationResponses Counter32,
|
|
docsIfCmStatusT1Timeouts Counter32,
|
|
docsIfCmStatusT2Timeouts Counter32,
|
|
docsIfCmStatusT3Timeouts Counter32,
|
|
docsIfCmStatusT4Timeouts Counter32,
|
|
docsIfCmStatusRangingAborteds Counter32,
|
|
docsIfCmStatusDocsisOperMode DocsisQosVersion,
|
|
docsIfCmStatusModulationType DocsisUpstreamTypeStatus,
|
|
docsIfCmStatusEqualizationData OCTET STRING
|
|
}
|
|
|
|
|
|
docsIfCmStatusValue OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
notReady(2),
|
|
notSynchronized(3),
|
|
phySynchronized(4),
|
|
usParametersAcquired(5),
|
|
rangingComplete(6),
|
|
ipComplete(7),
|
|
todEstablished(8),
|
|
securityEstablished(9),
|
|
paramTransferComplete(10),
|
|
registrationComplete(11),
|
|
operational(12),
|
|
accessDenied(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current Cable Modem connectivity state, as specified
|
|
in the RF Interface Specification. Interpretations for
|
|
state values 1-12 are clearly outlined in the Document [25]
|
|
reference given below.
|
|
As stated in the description for object docsIfCmtsCmStatusValue,
|
|
accessDenied(13)indicates the CMTS has sent a Registration
|
|
Aborted message to the CM."
|
|
REFERENCE
|
|
"Document [25] from References, Section 11.2.
|
|
Document [26] from References, Section 6.3.4.2."
|
|
::= { docsIfCmStatusEntry 1 }
|
|
|
|
docsIfCmStatusCode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status code for this Cable Modem as defined in the
|
|
RF Interface Specification. The status code consists
|
|
of a single character indicating error groups, followed
|
|
by a two- or three-digit number indicating the status
|
|
condition."
|
|
REFERENCE
|
|
"Document [26] from References, Appendix F."
|
|
::= { docsIfCmStatusEntry 2 }
|
|
|
|
docsIfCmStatusTxPower OBJECT-TYPE
|
|
SYNTAX TenthdBmV
|
|
UNITS "dBmV"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operational transmit power for the attached upstream
|
|
channel."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.18."
|
|
::= { docsIfCmStatusEntry 3 }
|
|
|
|
docsIfCmStatusResets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times the CM reset or initialized this interface."
|
|
::= { docsIfCmStatusEntry 4 }
|
|
|
|
docsIfCmStatusLostSyncs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times the CM lost synchronization with
|
|
the downstream channel."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.2."
|
|
::= { docsIfCmStatusEntry 5 }
|
|
|
|
|
|
docsIfCmStatusInvalidMaps OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times the CM received invalid MAP messages."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.4."
|
|
::= { docsIfCmStatusEntry 6 }
|
|
|
|
docsIfCmStatusInvalidUcds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times the CM received invalid UCD messages."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.3."
|
|
::= { docsIfCmStatusEntry 7 }
|
|
|
|
docsIfCmStatusInvalidRangingResponses OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times the CM received invalid ranging response
|
|
messages."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.6."
|
|
::= { docsIfCmStatusEntry 8 }
|
|
|
|
docsIfCmStatusInvalidRegistrationResponses OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times the CM received invalid registration
|
|
response messages."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.8."
|
|
::= { docsIfCmStatusEntry 9 }
|
|
|
|
docsIfCmStatusT1Timeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times counter T1 expired in the CM."
|
|
REFERENCE
|
|
"Document [25] from References, Figure 9-2."
|
|
::= { docsIfCmStatusEntry 10 }
|
|
|
|
docsIfCmStatusT2Timeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times counter T2 expired in the CM."
|
|
REFERENCE
|
|
"Document [25] from References, Figure 9-2."
|
|
::= { docsIfCmStatusEntry 11 }
|
|
|
|
docsIfCmStatusT3Timeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times counter T3 expired in the CM."
|
|
REFERENCE
|
|
"Document [25] from References, Figure 9-2."
|
|
::= { docsIfCmStatusEntry 12 }
|
|
|
|
docsIfCmStatusT4Timeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times counter T4 expired in the CM."
|
|
REFERENCE
|
|
"Document [25] from References, Figure 9-2."
|
|
::= { docsIfCmStatusEntry 13 }
|
|
|
|
docsIfCmStatusRangingAborteds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times the ranging process was aborted
|
|
by the CMTS."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.3.3."
|
|
::= { docsIfCmStatusEntry 14 }
|
|
|
|
docsIfCmStatusDocsisOperMode OBJECT-TYPE
|
|
SYNTAX DocsisQosVersion
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indication whether the device has registered using 1.0 Class of
|
|
Service or 1.1 Quality of Service.
|
|
An unregistered CM should indicate 1.1 QOS for a
|
|
docsIfDocsisBaseCapability value of Docsis 1.1/2.0. An unregistered
|
|
CM should indicate 1.0 COS for a docsIfDocsisBaseCapability value
|
|
of Docsis 1.0.
|
|
This object mirrors docsIfCmDocsisOperMode from the docsIfExt mib."
|
|
REFERENCE
|
|
"Document [25] from References, Annex G."
|
|
::= { docsIfCmStatusEntry 15 }
|
|
|
|
docsIfCmStatusModulationType OBJECT-TYPE
|
|
SYNTAX DocsisUpstreamTypeStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates modulation type status currently used by the CM.
|
|
Since this object specifically identifies PHY mode, the shared
|
|
upstream channel type is not permitted."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.1."
|
|
|
|
::= { docsIfCmStatusEntry 16 }
|
|
|
|
docsIfCmStatusEqualizationData OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pre-equalization data for this CM after convolution with
|
|
data indicated in the RNG-RSP.
|
|
Returns an empty string if the value is unknown or if there
|
|
is no equalization data available or defined. The value should
|
|
be formatted as defined in the following REFERENCE."
|
|
REFERENCE
|
|
"Document [25] from References, Figure 8-23."
|
|
::= { docsIfCmStatusEntry 17 }
|
|
|
|
|
|
--
|
|
-- The Cable Modem Service Table
|
|
--
|
|
|
|
docsIfCmServiceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the attributes of each upstream service queue
|
|
on a CM."
|
|
::= { docsIfCmObjects 3 }
|
|
|
|
docsIfCmServiceEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the attributes of an upstream bandwidth service
|
|
queue.
|
|
An entry in this table exists for each Service ID.
|
|
The primary index is an ifIndex with an ifType of
|
|
docsCableMaclayer(127)."
|
|
INDEX { ifIndex, docsIfCmServiceId }
|
|
::= { docsIfCmServiceTable 1 }
|
|
|
|
DocsIfCmServiceEntry ::= SEQUENCE {
|
|
docsIfCmServiceId Integer32,
|
|
docsIfCmServiceQosProfile Integer32,
|
|
docsIfCmServiceTxSlotsImmed Counter32,
|
|
docsIfCmServiceTxSlotsDed Counter32,
|
|
docsIfCmServiceTxRetries Counter32,
|
|
docsIfCmServiceTxExceededs Counter32,
|
|
docsIfCmServiceRqRetries Counter32,
|
|
docsIfCmServiceRqExceededs Counter32,
|
|
docsIfCmServiceExtTxSlotsImmed Counter64,
|
|
docsIfCmServiceExtTxSlotsDed Counter64
|
|
}
|
|
|
|
docsIfCmServiceId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16383)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies a service queue for upstream bandwidth. The
|
|
attributes of this service queue are shared between the
|
|
CM and the CMTS. The CMTS allocates upstream bandwidth
|
|
to this service queue based on requests from the CM and
|
|
on the class of service associated with this queue."
|
|
::= { docsIfCmServiceEntry 1 }
|
|
|
|
docsIfCmServiceQosProfile OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16383)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index in docsIfQosProfileTable describing the quality
|
|
of service attributes associated with this particular
|
|
service. If no associated entry in docsIfQosProfileTable
|
|
exists, this object returns a value of zero."
|
|
::= { docsIfCmServiceEntry 2 }
|
|
|
|
docsIfCmServiceTxSlotsImmed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of upstream mini-slots which have been used to
|
|
transmit data PDUs in immediate (contention) mode. This
|
|
includes only those PDUs that are presumed to have
|
|
arrived at the headend (i.e., those which were explicitly
|
|
acknowledged.) It does not include retransmission attempts
|
|
or mini-slots used by Requests."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.4."
|
|
::= { docsIfCmServiceEntry 3 }
|
|
|
|
docsIfCmServiceTxSlotsDed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of upstream mini-slots which have been used to
|
|
transmit data PDUs in dedicated mode (i.e., as a result
|
|
of a unicast Data Grant)."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.4."
|
|
::= { docsIfCmServiceEntry 4 }
|
|
|
|
docsIfCmServiceTxRetries OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of attempts to transmit data PDUs containing
|
|
requests for acknowledgment that did not result in
|
|
acknowledgment."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.4."
|
|
::= { docsIfCmServiceEntry 5 }
|
|
|
|
docsIfCmServiceTxExceededs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of data PDUs transmission failures due to
|
|
excessive retries without acknowledgment."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.4."
|
|
::= { docsIfCmServiceEntry 6 }
|
|
|
|
docsIfCmServiceRqRetries OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of attempts to transmit bandwidth requests
|
|
which did not result in acknowledgment."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.4."
|
|
::= { docsIfCmServiceEntry 7 }
|
|
|
|
|
|
docsIfCmServiceRqExceededs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of requests for bandwidth which failed due to
|
|
excessive retries without acknowledgment."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.4."
|
|
::= { docsIfCmServiceEntry 8 }
|
|
|
|
docsIfCmServiceExtTxSlotsImmed OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of upstream mini-slots which have been used to
|
|
transmit data PDUs in immediate (contention) mode. This
|
|
includes only those PDUs that are presumed to have
|
|
arrived at the headend (i.e., those which were explicitly
|
|
acknowledged.) It does not include retransmission attempts
|
|
or mini-slots used by Requests."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.4."
|
|
::= { docsIfCmServiceEntry 9 }
|
|
|
|
docsIfCmServiceExtTxSlotsDed OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of upstream mini-slots which have been used to
|
|
transmit data PDUs in dedicated mode (i.e., as a result
|
|
of a unicast Data Grant)."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.4."
|
|
::= { docsIfCmServiceEntry 10 }
|
|
|
|
|
|
|
|
--
|
|
-- CMTS GROUP
|
|
--
|
|
|
|
--
|
|
-- The CMTS MAC Table
|
|
--
|
|
|
|
docsIfCmtsMacTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmtsMacEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the attributes of each CMTS MAC interface,
|
|
extending the information available from ifEntry.
|
|
Mandatory for all CMTS devices."
|
|
::= { docsIfCmtsObjects 1 }
|
|
|
|
docsIfCmtsMacEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmtsMacEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects describing attributes of each
|
|
MAC entry, extending the information in ifEntry.
|
|
An entry in this table exists for each ifEntry with an
|
|
ifType of docsCableMaclayer(127)."
|
|
INDEX { ifIndex }
|
|
::= { docsIfCmtsMacTable 1 }
|
|
|
|
DocsIfCmtsMacEntry ::= SEQUENCE {
|
|
docsIfCmtsCapabilities BITS,
|
|
docsIfCmtsSyncInterval Integer32,
|
|
docsIfCmtsUcdInterval Integer32,
|
|
docsIfCmtsMaxServiceIds Integer32,
|
|
docsIfCmtsInsertionInterval TimeTicks, -- Obsolete
|
|
docsIfCmtsInvitedRangingAttempts Integer32,
|
|
docsIfCmtsInsertInterval TimeInterval
|
|
}
|
|
|
|
|
|
docsIfCmtsCapabilities OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
atmCells(0),
|
|
concatenation(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the capabilities of the CMTS MAC
|
|
implementation at this interface. Note that packet
|
|
transmission is always supported. Therefore, there
|
|
is no specific bit required to explicitly indicate
|
|
this capability.
|
|
Note that BITS objects are encoded most significant bit
|
|
first. For example, if bit 1 is set, the value of this
|
|
object is the octet string '40'H."
|
|
::= { docsIfCmtsMacEntry 1 }
|
|
|
|
docsIfCmtsSyncInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (1..200)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interval between CMTS transmission of successive SYNC
|
|
messages at this interface."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.3."
|
|
::= { docsIfCmtsMacEntry 2 }
|
|
|
|
docsIfCmtsUcdInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2000)
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interval between CMTS transmission of successive
|
|
Upstream Channel Descriptor messages for each upstream
|
|
channel at this interface."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.3"
|
|
::= { docsIfCmtsMacEntry 3 }
|
|
|
|
docsIfCmtsMaxServiceIds OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16383)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of service IDs that may be
|
|
simultaneously active."
|
|
::= { docsIfCmtsMacEntry 4 }
|
|
|
|
-- This object has been obsoleted and replaced by
|
|
-- docsIfCmtsInsertInterval to fix a SYNTAX typing problem. New
|
|
-- implementations of this MIB should use that object instead.
|
|
docsIfCmtsInsertionInterval OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The amount of time to elapse between each broadcast
|
|
station maintenance grant. Broadcast station maintenance
|
|
grants are used to allow new cable modems to join the
|
|
network. Zero indicates that a vendor-specific algorithm
|
|
is used instead of a fixed time. Maximum amount of time
|
|
permitted by the specification is 2 seconds."
|
|
REFERENCE
|
|
"Document [25] from References, Annex B."
|
|
::= { docsIfCmtsMacEntry 5 }
|
|
|
|
docsIfCmtsInvitedRangingAttempts OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1024)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of attempts to make on invitations
|
|
for ranging requests. A value of zero means the system
|
|
should attempt to range forever."
|
|
REFERENCE
|
|
"Document [25] from References, Section 9.3.3 and Annex B."
|
|
::= { docsIfCmtsMacEntry 6 }
|
|
|
|
docsIfCmtsInsertInterval OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time to elapse between each broadcast
|
|
station maintenance grant. Broadcast station maintenance
|
|
grants are used to allow new cable modems to join the
|
|
network. Zero indicates that a vendor-specific algorithm
|
|
is used instead of a fixed time. Maximum amount of time
|
|
permitted by the specification is 2 seconds."
|
|
REFERENCE
|
|
"Document [25] from References, Annex B."
|
|
::= { docsIfCmtsMacEntry 7 }
|
|
|
|
|
|
--
|
|
--
|
|
-- CMTS status table.
|
|
--
|
|
|
|
docsIfCmtsStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmtsStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For the MAC layer, this group maintains a number of
|
|
status objects and counters."
|
|
::= { docsIfCmtsObjects 2 }
|
|
|
|
docsIfCmtsStatusEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmtsStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status entry for a single MAC layer.
|
|
An entry in this table exists for each ifEntry with an
|
|
ifType of docsCableMaclayer(127)."
|
|
INDEX { ifIndex }
|
|
::= { docsIfCmtsStatusTable 1 }
|
|
|
|
DocsIfCmtsStatusEntry ::= SEQUENCE {
|
|
docsIfCmtsStatusInvalidRangeReqs Counter32,
|
|
docsIfCmtsStatusRangingAborteds Counter32,
|
|
docsIfCmtsStatusInvalidRegReqs Counter32,
|
|
docsIfCmtsStatusFailedRegReqs Counter32,
|
|
docsIfCmtsStatusInvalidDataReqs Counter32,
|
|
docsIfCmtsStatusT5Timeouts Counter32
|
|
}
|
|
|
|
docsIfCmtsStatusInvalidRangeReqs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object counts invalid RNG-REQ messages received on
|
|
this interface."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.5."
|
|
|
|
::= { docsIfCmtsStatusEntry 1 }
|
|
|
|
docsIfCmtsStatusRangingAborteds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object counts ranging attempts that were explicitly
|
|
aborted by the CMTS."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.6."
|
|
::= { docsIfCmtsStatusEntry 2 }
|
|
|
|
docsIfCmtsStatusInvalidRegReqs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object counts invalid REG-REQ messages received on
|
|
this interface. That is, syntax, out of range parameters,
|
|
or erroneous requests."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.7."
|
|
::= { docsIfCmtsStatusEntry 3 }
|
|
|
|
docsIfCmtsStatusFailedRegReqs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object counts failed registration attempts. Included are
|
|
docsIfCmtsStatusInvalidRegReqs, authentication and class of
|
|
service failures."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.3.7."
|
|
::= { docsIfCmtsStatusEntry 4 }
|
|
|
|
docsIfCmtsStatusInvalidDataReqs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object counts invalid data request messages
|
|
received on this interface."
|
|
::= { docsIfCmtsStatusEntry 5 }
|
|
|
|
docsIfCmtsStatusT5Timeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object counts the number of times counter T5
|
|
expired on this interface."
|
|
REFERENCE
|
|
"Document [25] from References, Figure 9-2."
|
|
::= { docsIfCmtsStatusEntry 6 }
|
|
|
|
|
|
--
|
|
-- CM status table (within CMTS).
|
|
-- This table is implemented only at the CMTS.
|
|
-- It contains per CM status information available in the CMTS.
|
|
--
|
|
|
|
docsIfCmtsCmStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmtsCmStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of objects in the CMTS, maintained for each
|
|
Cable Modem connected to this CMTS."
|
|
::= { docsIfCmtsObjects 3 }
|
|
|
|
docsIfCmtsCmStatusEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmtsCmStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status information for a single Cable Modem.
|
|
An entry in this table exists for each Cable Modem
|
|
that is connected to the CMTS implementing this table."
|
|
INDEX { docsIfCmtsCmStatusIndex }
|
|
::= { docsIfCmtsCmStatusTable 1 }
|
|
|
|
DocsIfCmtsCmStatusEntry ::= SEQUENCE {
|
|
docsIfCmtsCmStatusIndex Integer32,
|
|
docsIfCmtsCmStatusMacAddress MacAddress,
|
|
docsIfCmtsCmStatusIpAddress IpAddress, -- Deprecated
|
|
docsIfCmtsCmStatusDownChannelIfIndex InterfaceIndexOrZero,
|
|
docsIfCmtsCmStatusUpChannelIfIndex InterfaceIndexOrZero,
|
|
docsIfCmtsCmStatusRxPower TenthdBmV,
|
|
docsIfCmtsCmStatusTimingOffset Unsigned32,
|
|
docsIfCmtsCmStatusEqualizationData OCTET STRING,
|
|
docsIfCmtsCmStatusValue INTEGER,
|
|
docsIfCmtsCmStatusUnerroreds Counter32,
|
|
docsIfCmtsCmStatusCorrecteds Counter32,
|
|
docsIfCmtsCmStatusUncorrectables Counter32,
|
|
docsIfCmtsCmStatusSignalNoise TenthdB,
|
|
docsIfCmtsCmStatusMicroreflections Integer32,
|
|
docsIfCmtsCmStatusExtUnerroreds Counter64,
|
|
docsIfCmtsCmStatusExtCorrecteds Counter64,
|
|
docsIfCmtsCmStatusExtUncorrectables Counter64,
|
|
docsIfCmtsCmStatusDocsisRegMode DocsisQosVersion,
|
|
docsIfCmtsCmStatusModulationType DocsisUpstreamTypeStatus,
|
|
docsIfCmtsCmStatusInetAddressType InetAddressType,
|
|
docsIfCmtsCmStatusInetAddress InetAddress,
|
|
docsIfCmtsCmStatusValueLastUpdate TimeStamp
|
|
}
|
|
|
|
docsIfCmtsCmStatusIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index value to uniquely identify an entry in this table.
|
|
For an individual Cable Modem, this index value should
|
|
not change during CMTS uptime."
|
|
::= { docsIfCmtsCmStatusEntry 1 }
|
|
|
|
docsIfCmtsCmStatusMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC address of this Cable Modem. If the Cable Modem has
|
|
multiple MAC addresses, this is the MAC address associated
|
|
with the Cable interface."
|
|
REFERENCE
|
|
"Document [25] from References, Section 8.2.2."
|
|
::= { docsIfCmtsCmStatusEntry 2 }
|
|
|
|
docsIfCmtsCmStatusIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"IP address of this Cable Modem. If the Cable Modem has no
|
|
IP address assigned, or the IP address is unknown, this
|
|
object returns a value of 0.0.0.0. If the Cable Modem has
|
|
multiple IP addresses, this object returns the IP address
|
|
associated with the Cable interface.
|
|
This object has been deprecated and replaced by
|
|
docsIfCmtsCmStatusInetAddressType and
|
|
docsIfCmtsCmStatusInetAddress, to enable IPv6 addressing
|
|
in the future."
|
|
::= { docsIfCmtsCmStatusEntry 3 }
|
|
|
|
docsIfCmtsCmStatusDownChannelIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IfIndex of the downstream channel this CM is connected
|
|
to. If the downstream channel is unknown, this object
|
|
returns a value of zero."
|
|
::= { docsIfCmtsCmStatusEntry 4 }
|
|
|
|
docsIfCmtsCmStatusUpChannelIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IfIndex of the upstream channel this CM is connected
|
|
to. If the upstream channel is unknown, this object
|
|
returns a value of zero."
|
|
::= { docsIfCmtsCmStatusEntry 5 }
|
|
|
|
docsIfCmtsCmStatusRxPower OBJECT-TYPE
|
|
SYNTAX TenthdBmV
|
|
UNITS "dBmV"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The receive power as perceived for upstream data from
|
|
this Cable Modem.
|
|
If the receive power is unknown, this object returns
|
|
a value of zero."
|
|
REFERENCE
|
|
"Document [25] from References, Table 6-11."
|
|
::= { docsIfCmtsCmStatusEntry 6 }
|
|
|
|
docsIfCmtsCmStatusTimingOffset OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measure of the current round trip time for this CM.
|
|
Used for timing of CM upstream transmissions to ensure
|
|
synchronized arrivals at the CMTS. Units are in terms
|
|
of 6.25 microseconds/(64*256). Returns zero if the value
|
|
is unknown."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.18."
|
|
::= { docsIfCmtsCmStatusEntry 7 }
|
|
|
|
docsIfCmtsCmStatusEqualizationData OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Equalization data for this CM. Returns an empty string
|
|
if the value is unknown or if there is no equalization
|
|
data available or defined."
|
|
REFERENCE
|
|
"Document [25] from References, Figure 8-23."
|
|
::= { docsIfCmtsCmStatusEntry 8 }
|
|
|
|
docsIfCmtsCmStatusValue OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ranging(2),
|
|
rangingAborted(3),
|
|
rangingComplete(4),
|
|
ipComplete(5),
|
|
registrationComplete(6),
|
|
accessDenied(7),
|
|
operational(8), -- deprecated, ECN OSS2-N-03069
|
|
registeredBPIInitializing(9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current Cable Modem connectivity state, as specified
|
|
in the RF Interface Specification. Returned status
|
|
information is the CM status as assumed by the CMTS,
|
|
and indicates the following events:
|
|
other(1)
|
|
Any state other than below.
|
|
ranging(2)
|
|
The CMTS has received an Initial Ranging Request
|
|
message from the CM, and the ranging process is not
|
|
yet complete.
|
|
rangingAborted(3)
|
|
The CMTS has sent a Ranging Abort message to the CM.
|
|
rangingComplete(4)
|
|
The CMTS has sent a Ranging Complete message to the CM.
|
|
ipComplete(5)
|
|
The CMTS has received a DHCP reply message and forwarded
|
|
it to the CM.
|
|
registrationComplete(6)
|
|
The CMTS has sent a Registration Response message to
|
|
the CM.
|
|
accessDenied(7)
|
|
The CMTS has sent a Registration Aborted message
|
|
to the CM.
|
|
operational(8)
|
|
If Baseline Privacy is enabled for the CM, the CMTS has
|
|
completed Baseline Privacy initialization. If Baseline
|
|
Privacy is not enabled, equivalent to registrationComplete.
|
|
registeredBPIInitializing(9)
|
|
Baseline Privacy is enabled, CMTS is in the process of
|
|
completing the Baseline Privacy initialization. This state
|
|
can last for a significant time in the case of failures
|
|
during the process. After Baseline Privacy initialization
|
|
is complete, the CMTS will repost back the value
|
|
registrationComplete(6).
|
|
|
|
The CMTS only needs to report states it is able to detect."
|
|
REFERENCE
|
|
"Document [25] from References, Section 11.2."
|
|
::= { docsIfCmtsCmStatusEntry 9 }
|
|
|
|
docsIfCmtsCmStatusUnerroreds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received without error from this Cable Modem."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfCmtsCmStatusEntry 10 }
|
|
|
|
docsIfCmtsCmStatusCorrecteds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received with correctable errors from this
|
|
Cable Modem."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfCmtsCmStatusEntry 11 }
|
|
|
|
docsIfCmtsCmStatusUncorrectables OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received with uncorrectable errors from this
|
|
Cable Modem."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfCmtsCmStatusEntry 12 }
|
|
|
|
docsIfCmtsCmStatusSignalNoise OBJECT-TYPE
|
|
SYNTAX TenthdB
|
|
UNITS "dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signal/Noise ratio as perceived for upstream data from
|
|
this Cable Modem.
|
|
If the Signal/Noise is unknown, this object returns
|
|
a value of zero."
|
|
REFERENCE
|
|
"Document [25] from References, Tables 4-1 and 4-2."
|
|
::= { docsIfCmtsCmStatusEntry 13 }
|
|
|
|
docsIfCmtsCmStatusMicroreflections OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
UNITS "dBc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total microreflections including in-channel response
|
|
as perceived on this interface, measured in dBc below
|
|
the signal level.
|
|
This object is not assumed to return an absolutely
|
|
accurate value, but should give a rough indication
|
|
of microreflections received on this interface.
|
|
It is up to the implementer to provide information
|
|
as accurate as possible."
|
|
REFERENCE
|
|
"Document [25] from References, Tables 4-1 and 4-2"
|
|
::= { docsIfCmtsCmStatusEntry 14 }
|
|
|
|
docsIfCmtsCmStatusExtUnerroreds OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received without error from this Cable Modem."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfCmtsCmStatusEntry 15 }
|
|
|
|
docsIfCmtsCmStatusExtCorrecteds OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received with correctable errors from this
|
|
Cable Modem."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfCmtsCmStatusEntry 16 }
|
|
|
|
docsIfCmtsCmStatusExtUncorrectables OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Codewords received with uncorrectable errors from this
|
|
Cable Modem."
|
|
REFERENCE
|
|
"Document [25] from References, Section 6.2.5."
|
|
::= { docsIfCmtsCmStatusEntry 17 }
|
|
|
|
docsIfCmtsCmStatusDocsisRegMode OBJECT-TYPE
|
|
SYNTAX DocsisQosVersion
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Indication whether the CM has registered using 1.0 Class of
|
|
Service or 1.1 Quality of Service.
|
|
This object mirrors docsIfCmtsCmStatusDocsisMode from the
|
|
docsIfExt mib."
|
|
REFERENCE
|
|
"Document [25] from References, Annex G."
|
|
::= { docsIfCmtsCmStatusEntry 18 }
|
|
|
|
docsIfCmtsCmStatusModulationType OBJECT-TYPE
|
|
SYNTAX DocsisUpstreamTypeStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates modulation type currently used by the CM. Since
|
|
this object specifically identifies PHY mode, the shared
|
|
type is not permitted. If the upstream channel is unknown,
|
|
this object returns a value of zero."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
::= { docsIfCmtsCmStatusEntry 19 }
|
|
|
|
docsIfCmtsCmStatusInetAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of internet address of
|
|
docsIfCmtsCmStatusInetAddress. If the cable modem
|
|
Internet address is unassigned or unknown, then the
|
|
value of this object is unknown(0)."
|
|
::= { docsIfCmtsCmStatusEntry 20 }
|
|
|
|
docsIfCmtsCmStatusInetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internet address of this Cable Modem. If the Cable Modem
|
|
has no Internet address assigned, or the Internet address
|
|
is unknown, the value of this object is the empty string.
|
|
If the Cable Modem has multiple Internet addresses, this
|
|
object returns the Internet address associated with the
|
|
Cable (i.e. RF MAC) interface."
|
|
::= { docsIfCmtsCmStatusEntry 21 }
|
|
|
|
docsIfCmtsCmStatusValueLastUpdate OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when docsIfCmtsCmStatusValue was last updated"
|
|
::= { docsIfCmtsCmStatusEntry 22 }
|
|
|
|
--
|
|
-- The CMTS Service Table.
|
|
--
|
|
|
|
docsIfCmtsServiceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmtsServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the attributes of upstream service queues
|
|
in a Cable Modem Termination System."
|
|
::= { docsIfCmtsObjects 4 }
|
|
|
|
docsIfCmtsServiceEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmtsServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the attributes of a single upstream bandwidth
|
|
service queue.
|
|
|
|
|
|
INTERNET-DRAFT DOCSIS RF Interface MIB November 2001
|
|
|
|
|
|
|
|
Entries in this table exist for each ifEntry with an
|
|
ifType of docsCableMaclayer(127), and for each service
|
|
queue (Service ID) within this MAC layer.
|
|
Entries in this table are created with the creation of
|
|
individual Service IDs by the MAC layer and removed
|
|
when a Service ID is removed."
|
|
INDEX { ifIndex, docsIfCmtsServiceId }
|
|
::= { docsIfCmtsServiceTable 1 }
|
|
|
|
DocsIfCmtsServiceEntry ::= SEQUENCE {
|
|
docsIfCmtsServiceId Integer32,
|
|
docsIfCmtsServiceCmStatusIndex Integer32, -- Deprecated
|
|
docsIfCmtsServiceAdminStatus INTEGER,
|
|
docsIfCmtsServiceQosProfile Integer32,
|
|
docsIfCmtsServiceCreateTime TimeStamp,
|
|
docsIfCmtsServiceInOctets Counter32,
|
|
docsIfCmtsServiceInPackets Counter32,
|
|
docsIfCmtsServiceNewCmStatusIndex Integer32
|
|
}
|
|
|
|
docsIfCmtsServiceId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16383)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies a service queue for upstream bandwidth. The
|
|
attributes of this service queue are shared between the
|
|
Cable Modem and the Cable Modem Termination System.
|
|
The CMTS allocates upstream bandwidth to this service
|
|
queue based on requests from the CM and on the class of
|
|
service associated with this queue."
|
|
::= { docsIfCmtsServiceEntry 1 }
|
|
|
|
docsIfCmtsServiceCmStatusIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Pointer to an entry in docsIfCmtsCmStatusTable identifying
|
|
the Cable Modem using this Service Queue. If multiple
|
|
Cable Modems are using this Service Queue, the value of
|
|
this object is zero.
|
|
This object has been deprecated and replaced by
|
|
docsIfCmtsServiceNewCmStatusIndex, to fix a mismatch
|
|
of the value range with respect to docsIfCmtsCmStatusIndex
|
|
(1..2147483647)."
|
|
::= { docsIfCmtsServiceEntry 2 }
|
|
|
|
docsIfCmtsServiceAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2),
|
|
destroyed(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Allows a service class for a particular modem to be
|
|
suppressed, (re-)enabled, or deleted altogether."
|
|
::= { docsIfCmtsServiceEntry 3 }
|
|
|
|
docsIfCmtsServiceQosProfile OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16383)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index in docsIfQosProfileTable describing the quality
|
|
of service attributes associated with this particular
|
|
service. If no associated docsIfQosProfileTable entry
|
|
exists, this object returns a value of zero."
|
|
::= { docsIfCmtsServiceEntry 4 }
|
|
|
|
docsIfCmtsServiceCreateTime OBJECT-TYPE
|
|
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when this entry was created."
|
|
::= { docsIfCmtsServiceEntry 5 }
|
|
|
|
docsIfCmtsServiceInOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The cumulative number of Packet Data octets received
|
|
on this Service ID. The count does not include the
|
|
size of the Cable MAC header"
|
|
::= { docsIfCmtsServiceEntry 6 }
|
|
|
|
docsIfCmtsServiceInPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The cumulative number of Packet Data packets received
|
|
on this Service ID."
|
|
::= { docsIfCmtsServiceEntry 7 }
|
|
|
|
docsIfCmtsServiceNewCmStatusIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pointer (via docsIfCmtsCmStatusIndex) to an entry in
|
|
docsIfCmtsCmStatusTable identifying the Cable Modem
|
|
using this Service Queue. If multiple Cable Modems are
|
|
using this Service Queue, the value of this object is
|
|
zero."
|
|
::= { docsIfCmtsServiceEntry 8 }
|
|
|
|
--
|
|
-- The following table provides upstream channel modulation profiles.
|
|
-- Entries in this table can be
|
|
-- re-used by one or more upstream channels. An upstream channel will
|
|
-- have a modulation profile
|
|
-- for each value of docsIfModIntervalUsageCode.
|
|
--
|
|
|
|
|
|
docsIfCmtsModulationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmtsModulationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes a modulation profile associated with one or more
|
|
upstream channels."
|
|
::= { docsIfCmtsObjects 5 }
|
|
|
|
docsIfCmtsModulationEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmtsModulationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes a modulation profile for an Interval Usage Code
|
|
for one or more upstream channels.
|
|
Entries in this table are created by the operator. Initial
|
|
default entries may be created at system initialization
|
|
time. No individual objects have to be specified in order
|
|
to create an entry in this table.
|
|
Note that some objects do not have DEFVALs, but do have
|
|
calculated defaults and need not be specified during row
|
|
creation.
|
|
There is no restriction on the changing of values in this
|
|
table while their associated rows are active."
|
|
INDEX { docsIfCmtsModIndex, docsIfCmtsModIntervalUsageCode}
|
|
::= { docsIfCmtsModulationTable 1 }
|
|
|
|
DocsIfCmtsModulationEntry ::= SEQUENCE {
|
|
docsIfCmtsModIndex Integer32,
|
|
docsIfCmtsModIntervalUsageCode INTEGER,
|
|
docsIfCmtsModControl RowStatus,
|
|
docsIfCmtsModType INTEGER,
|
|
docsIfCmtsModPreambleLen Integer32,
|
|
docsIfCmtsModDifferentialEncoding TruthValue,
|
|
docsIfCmtsModFECErrorCorrection Integer32,
|
|
docsIfCmtsModFECCodewordLength Integer32,
|
|
docsIfCmtsModScramblerSeed Integer32,
|
|
docsIfCmtsModMaxBurstSize Integer32,
|
|
docsIfCmtsModGuardTimeSize Unsigned32,
|
|
docsIfCmtsModLastCodewordShortened TruthValue,
|
|
docsIfCmtsModScrambler TruthValue,
|
|
docsIfCmtsModByteInterleaverDepth Unsigned32,
|
|
docsIfCmtsModByteInterleaverBlockSize Unsigned32,
|
|
docsIfCmtsModPreambleType INTEGER,
|
|
docsIfCmtsModTcmErrorCorrectionOn TruthValue,
|
|
docsIfCmtsModScdmaInterleaverStepSize Unsigned32,
|
|
docsIfCmtsModScdmaSpreaderEnable TruthValue,
|
|
docsIfCmtsModScdmaSubframeCodes Unsigned32,
|
|
docsIfCmtsModChannelType DocsisUpstreamType
|
|
}
|
|
|
|
docsIfCmtsModIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index into the Channel Modulation table representing
|
|
a group of Interval Usage Codes, all associated with the
|
|
same channel."
|
|
::= { docsIfCmtsModulationEntry 1 }
|
|
|
|
docsIfCmtsModIntervalUsageCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
request(1),
|
|
requestData(2),
|
|
initialRanging(3),
|
|
periodicRanging(4),
|
|
shortData(5),
|
|
longData(6),
|
|
advPhyShortData(9),
|
|
advPhyLongData(10),
|
|
ugs(11)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index into the Channel Modulation table which, when
|
|
grouped with other Interval Usage Codes, fully
|
|
instantiate all modulation sets for a given upstream
|
|
channel."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-20."
|
|
::= { docsIfCmtsModulationEntry 2 }
|
|
|
|
docsIfCmtsModControl OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls and reflects the status of rows in this table."
|
|
::= { docsIfCmtsModulationEntry 3 }
|
|
|
|
docsIfCmtsModType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
qpsk(2),
|
|
qam16(3),
|
|
qam8(4),
|
|
qam32(5),
|
|
qam64(6),
|
|
qam128(7),
|
|
qam256(8)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The modulation type used on this channel. Returns
|
|
other(1) if the modulation type is neither
|
|
qpsk, qam16, qam8, qam32, qam64 or qam128.
|
|
Type qam128 is used for SCDMA channels only.
|
|
See the reference for the modulation profiles
|
|
implied by different modulation types."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { qpsk }
|
|
::= { docsIfCmtsModulationEntry 4 }
|
|
|
|
docsIfCmtsModPreambleLen OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1536)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The preamble length for this modulation profile in bits.
|
|
Default value is the minimum needed by the implementation
|
|
at the CMTS for the given modulation profile."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
::= { docsIfCmtsModulationEntry 5 }
|
|
|
|
docsIfCmtsModDifferentialEncoding OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether or not differential encoding is used
|
|
on this channel."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { false }
|
|
::= { docsIfCmtsModulationEntry 6 }
|
|
|
|
docsIfCmtsModFECErrorCorrection OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of correctable errored bytes (t) used in
|
|
forward error correction code. The value of 0 indicates
|
|
no correction is employed. The number of check bytes
|
|
appended will be twice this value."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { 0 }
|
|
::= { docsIfCmtsModulationEntry 7 }
|
|
|
|
docsIfCmtsModFECCodewordLength OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of data bytes (k) in the forward error
|
|
correction codeword.
|
|
This object is not used if docsIfCmtsModFECErrorCorrection
|
|
is zero."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { 32 }
|
|
::= { docsIfCmtsModulationEntry 8 }
|
|
|
|
docsIfCmtsModScramblerSeed OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 15 bit seed value for the scrambler polynomial."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { 0 }
|
|
::= { docsIfCmtsModulationEntry 9 }
|
|
|
|
docsIfCmtsModMaxBurstSize OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of mini-slots that can be transmitted
|
|
during this channel's burst time. Returns zero if the
|
|
burst length is bounded by the allocation MAP rather than
|
|
this profile.
|
|
Default value is 0 except for shortData, where it is 8."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
::= { docsIfCmtsModulationEntry 10 }
|
|
|
|
docsIfCmtsModGuardTimeSize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of symbol-times which must follow the end of
|
|
this channel's burst. Default value is the minimum time
|
|
needed by the implementation for this modulation profile."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
::= { docsIfCmtsModulationEntry 11 }
|
|
|
|
docsIfCmtsModLastCodewordShortened OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the last FEC codeword is truncated."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { true }
|
|
::= { docsIfCmtsModulationEntry 12 }
|
|
|
|
docsIfCmtsModScrambler OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the scrambler is employed."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { false }
|
|
::= { docsIfCmtsModulationEntry 13 }
|
|
|
|
docsIfCmtsModByteInterleaverDepth OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ATDMA Byte Interleaver Depth (Ir). This object returns 1 for
|
|
non ATDMA profiles. "
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { 1 }
|
|
::= { docsIfCmtsModulationEntry 14 }
|
|
|
|
docsIfCmtsModByteInterleaverBlockSize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" ATDMA Byte Interleaver Block size (Br). This object returns
|
|
zero for non ATDMA profiles "
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { 18 }
|
|
::= { docsIfCmtsModulationEntry 15 }
|
|
|
|
docsIfCmtsModPreambleType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
qpsk0(1),
|
|
qpsk1(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Preamble type for DOCSIS 2.0 bursts"
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { qpsk0 }
|
|
::= { docsIfCmtsModulationEntry 16 }
|
|
|
|
docsIfCmtsModTcmErrorCorrectionOn OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Trellis Code Modulation (TCM) On/Off. This value returns false for
|
|
non S-CDMA profiles."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { false }
|
|
::= { docsIfCmtsModulationEntry 17 }
|
|
|
|
docsIfCmtsModScdmaInterleaverStepSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0 | 1..32)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" S-CDMA Interleaver step size. This value returns zero
|
|
for non S-CDMA profiles."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
|
|
DEFVAL { 1 }
|
|
::= { docsIfCmtsModulationEntry 18 }
|
|
|
|
docsIfCmtsModScdmaSpreaderEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" S-CDMA spreader. This value returns false for non S-CDMA
|
|
profiles. Default value for IUC 3 and 4 is OFF, for
|
|
all other IUCs it is ON."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
::= { docsIfCmtsModulationEntry 19 }
|
|
|
|
docsIfCmtsModScdmaSubframeCodes OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0 | 1..128)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" S-CDMA sub-frame size. This value returns zero
|
|
for non S-CDMA profiles."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { 1 }
|
|
::= { docsIfCmtsModulationEntry 20 }
|
|
|
|
docsIfCmtsModChannelType OBJECT-TYPE
|
|
SYNTAX DocsisUpstreamType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the modulation channel type for this modulation entry."
|
|
REFERENCE
|
|
"Document [25] from References, Table 8-19."
|
|
DEFVAL { tdma }
|
|
::= { docsIfCmtsModulationEntry 21 }
|
|
|
|
docsIfCmtsQosProfilePermissions OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
createByManagement(0),
|
|
updateByManagement(1),
|
|
createByModems(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies permitted methods of creating
|
|
entries in docsIfQosProfileTable.
|
|
CreateByManagement(0) is set if entries can be created
|
|
using SNMP. UpdateByManagement(1) is set if updating
|
|
entries using SNMP is permitted. CreateByModems(2)
|
|
is set if entries can be created based on information
|
|
in REG-REQ MAC messages received from Cable Modems.
|
|
Information in this object is only applicable if
|
|
docsIfQosProfileTable is implemented as read-create.
|
|
Otherwise, this object is implemented as read-only
|
|
and returns CreateByModems(2).
|
|
Either CreateByManagement(0) or CreateByModems(1)
|
|
must be set when writing to this object.
|
|
Note that BITS objects are encoded most significant bit
|
|
first. For example, if bit 2 is set, the value of this
|
|
object is the octet string '20'H."
|
|
::= { docsIfCmtsObjects 6 }
|
|
|
|
docsIfCmtsMacToCmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmtsMacToCmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a table to provide a quick access index into the
|
|
docsIfCmtsCmStatusTable. There is exactly one row in this
|
|
table for each row in the docsIfCmtsCmStatusTable. In
|
|
general, the management station should use this table only
|
|
to get a pointer into the docsIfCmtsCmStatusTable (which
|
|
corresponds to the CM's RF interface MAC address), and
|
|
should not iterate (e.g. GetNext through) this table."
|
|
::= { docsIfCmtsObjects 7 }
|
|
|
|
docsIfCmtsMacToCmEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmtsMacToCmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the docsIfCmtsMacToCmTable.
|
|
An entry in this table exists for each Cable Modem
|
|
that is connected to the CMTS implementing this table."
|
|
INDEX { docsIfCmtsCmMac }
|
|
::= {docsIfCmtsMacToCmTable 1 }
|
|
|
|
DocsIfCmtsMacToCmEntry ::= SEQUENCE {
|
|
docsIfCmtsCmMac MacAddress,
|
|
docsIfCmtsCmPtr Integer32
|
|
}
|
|
|
|
docsIfCmtsCmMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RF side MAC address for the referenced CM. (E.g. the
|
|
interface on the CM that has docsCableMacLayer(127) as
|
|
its ifType."
|
|
::= { docsIfCmtsMacToCmEntry 1 }
|
|
|
|
docsIfCmtsCmPtr OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An row index into docsIfCmtsCmStatusTable. When queried
|
|
with the correct instance value (e.g. a CM's MAC address),
|
|
returns the index in docsIfCmtsCmStatusTable which
|
|
represents that CM."
|
|
::= { docsIfCmtsMacToCmEntry 2 }
|
|
|
|
|
|
-- The following independent object and associated table provide
|
|
-- operators with a mechanism to evaluate the load/utilization of
|
|
-- both upstream and downstream physical channels. This information
|
|
-- may be used for capacity planning and incident analysis, and may
|
|
-- be particularly helpful in provisioning of high value QOS.
|
|
--
|
|
-- Utilization is expressed as an index representing the calculated
|
|
-- percentage utilization of the upstream or downstream channel in
|
|
-- the most recent sampling interval (ie. utilization interval).
|
|
-- Refer to the DESCRIPTION field of the docsIfCmtsChannelUtUtilization
|
|
-- object for definitions and calculation details.
|
|
|
|
|
|
docsIfCmtsChannelUtilizationInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (0..86400)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time interval in seconds over which the channel utilization
|
|
index is calculated. All upstream/downstream channels use the
|
|
same docsIfCmtsChannelUtilizationInterval.
|
|
Setting a value of zero disables utilization reporting.
|
|
A channel utilization index is calculated over a fixed window
|
|
applying to the most recent docsIfCmtsChannelUtilizationInterval.
|
|
It would therefore be prudent to use a relatively short
|
|
docsIfCmtsChannelUtilizationInterval."
|
|
::= { docsIfCmtsObjects 8 }
|
|
|
|
|
|
docsIfCmtsChannelUtilizationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmtsChannelUtilizationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports utilization statistics for attached upstream and
|
|
downstream physical channels."
|
|
::= { docsIfCmtsObjects 9 }
|
|
|
|
docsIfCmtsChannelUtilizationEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmtsChannelUtilizationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Utilization statistics for a single upstream or downstream
|
|
physical channel. An entry exists in this table for each
|
|
ifEntry with an ifType equal to docsCableDownstreamInterface
|
|
(128) or docsCableUpstreamInterface (129)."
|
|
INDEX { ifIndex, docsIfCmtsChannelUtIfType, docsIfCmtsChannelUtId }
|
|
::= { docsIfCmtsChannelUtilizationTable 1 }
|
|
|
|
DocsIfCmtsChannelUtilizationEntry ::= SEQUENCE {
|
|
docsIfCmtsChannelUtIfType IANAifType,
|
|
docsIfCmtsChannelUtId Integer32,
|
|
docsIfCmtsChannelUtUtilization Integer32
|
|
}
|
|
|
|
docsIfCmtsChannelUtIfType OBJECT-TYPE
|
|
SYNTAX IANAifType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The secondary index into this table. Indicates the IANA
|
|
interface type associated with this physical channel. Only
|
|
docsCableDownstreamInterface (128) and
|
|
docsCableUpstreamInterface (129) are valid."
|
|
::= { docsIfCmtsChannelUtilizationEntry 1 }
|
|
|
|
docsIfCmtsChannelUtId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tertiary index into this table. Indicates the CMTS
|
|
identifier for this physical channel."
|
|
::= { docsIfCmtsChannelUtilizationEntry 2 }
|
|
|
|
docsIfCmtsChannelUtUtilization OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The calculated and truncated utilization index for this
|
|
physical upstream or downstream channel, accurate as of
|
|
the most recent docsIfCmtsChannelUtilizationInterval.
|
|
|
|
Upstream Channel Utilization Index:
|
|
The upstream channel utilization index is expressed as a
|
|
percentage of minislots utilized on the physical channel, regardless
|
|
of burst type. For an Initial Maintenance region, the minislots
|
|
for the complete region are considered utilized if the CMTS
|
|
received an upstream burst within the region from any CM on the
|
|
physical channel. For contention REQ and REQ/DATA regions, the
|
|
minislots for a transmission opportunity within the region are
|
|
considered utilized if the CMTS received an upstream burst within
|
|
the opportunity from any CM on the physical channel. For all other
|
|
regions, utilized minislots are those in which the CMTS granted
|
|
bandwidth to any unicast SID on the physical channel.
|
|
|
|
For an upstream interface that has multiple logical upstream
|
|
channels enabled, the utilization index is a weighted sum of
|
|
utilization indices for the logical channels. The weight for
|
|
each utilization index is the percentage of upstream minislots
|
|
allocated for the corresponding logical channel.
|
|
Example:
|
|
If 75% of bandwidth is allocated to the first logical channel
|
|
and 25% to the second, and the utilization indices for each are
|
|
60 and 40 respectively, the utilization index for the upstream
|
|
physical channel is (60 * 0.75) + (40 * 0.25) = 55. This figure
|
|
applies to the most recent utilization interval.
|
|
|
|
Downstream Channel Utilization Index:
|
|
The downstream channel utilization index is a percentage expressing
|
|
the ratio between bytes used to transmit data versus the total number
|
|
of bytes transmitted in the raw bandwidth of the MPEG channel. As
|
|
with the upstream utilization index, the calculated value represents
|
|
the most recent utilization interval.
|
|
Formula:
|
|
Downstream utilization index =
|
|
(100 * (data bytes / raw bytes)) =
|
|
(100 * ((raw bytes - stuffed bytes) / raw bytes))
|
|
|
|
Definitions:
|
|
Data bytes: Number of bytes transmitted as data in the
|
|
docsIfCmtsChannelUtilizationInterval.
|
|
Stuffed bytes: Number of filler bytes transmitted as non-data in the
|
|
DocsIfCmtsChannelUtilizationInterval.
|
|
Raw bandwidth: Total number of bytes available for transmitting data,
|
|
not including bytes used for headers and other overhead.
|
|
Raw bytes: (raw bandwidth * docsIfCmtsChannelUtilizationInterval)."
|
|
|
|
::= { docsIfCmtsChannelUtilizationEntry 3 }
|
|
|
|
|
|
-- The following table provides operators with input data appropriate for
|
|
-- calculating downstream channel utilization. Operators may use the
|
|
-- docsIfCmtsChannelUtilizationTable, or perform their own polling of the
|
|
-- docsIfCmtsDownChannelCounterTable objects to characterize their downstream
|
|
-- channel usage.
|
|
-- The 32 bit counter objects are included to provide backward compatibility
|
|
-- with SNMPv1 managers, which cannot access 64 bit counter objects.
|
|
|
|
docsIfCmtsDownChannelCounterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmtsDownChannelCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is implemented at the CMTS to collect downstream
|
|
channel statistics for utilization calculations."
|
|
::= { docsIfCmtsObjects 10 }
|
|
|
|
docsIfCmtsDownChannelCounterEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmtsDownChannelCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry provides a list of traffic counters for a single
|
|
downstream channel.
|
|
An entry in this table exists for each ifEntry with an
|
|
ifType of docsCableDownstream(128)."
|
|
INDEX { ifIndex }
|
|
::= { docsIfCmtsDownChannelCounterTable 1 }
|
|
|
|
DocsIfCmtsDownChannelCounterEntry ::= SEQUENCE {
|
|
docsIfCmtsDownChnlCtrId Integer32,
|
|
docsIfCmtsDownChnlCtrTotalBytes Counter32,
|
|
docsIfCmtsDownChnlCtrUsedBytes Counter32,
|
|
docsIfCmtsDownChnlCtrExtTotalBytes Counter64,
|
|
docsIfCmtsDownChnlCtrExtUsedBytes Counter64
|
|
}
|
|
|
|
docsIfCmtsDownChnlCtrId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Cable Modem Termination System (CMTS) identification
|
|
of the downstream channel within this particular MAC
|
|
interface. If the interface is down, the object returns
|
|
the most current value. If the downstream channel ID is
|
|
unknown, this object returns a value of 0."
|
|
::= { docsIfCmtsDownChannelCounterEntry 1 }
|
|
|
|
docsIfCmtsDownChnlCtrTotalBytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At the CMTS, the total number of bytes in the Payload portion
|
|
of MPEG Packets (ie. not including MPEG header or pointer_field)
|
|
transported by this downstream channel since CMTS initialization.
|
|
This is the 32 bit version of docsIfCmtsDownChnlCtrExtTotalBytes,
|
|
included to provide back compatibility with SNMPv1 managers."
|
|
::= { docsIfCmtsDownChannelCounterEntry 2 }
|
|
|
|
docsIfCmtsDownChnlCtrUsedBytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At the CMTS, the total number of DOCSIS data bytes transported
|
|
by this downstream channel since CMTS initialization. The number
|
|
of data bytes is defined as the total number of bytes transported
|
|
in DOCSIS payloads minus the number of stuff bytes transported in
|
|
DOCSIS payloads.
|
|
This is the 32 bit version of docsIfCmtsDownChnlCtrExtUsedBytes,
|
|
included to provide back compatibility with SNMPv1 managers."
|
|
::= { docsIfCmtsDownChannelCounterEntry 3 }
|
|
|
|
docsIfCmtsDownChnlCtrExtTotalBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At the CMTS, the total number of bytes in the Payload portion
|
|
of MPEG Packets (ie. not including MPEG header or pointer_field)
|
|
transported by this downstream channel since CMTS initialization.
|
|
This is the 64 bit version of docsIfCmtsDownChnlCtrTotalBytes, and
|
|
will not be accessible to SNMPv1 managers."
|
|
::= { docsIfCmtsDownChannelCounterEntry 4 }
|
|
|
|
docsIfCmtsDownChnlCtrExtUsedBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At the CMTS, the total number of DOCSIS data bytes transported
|
|
by this downstream channel since CMTS initialization. The number
|
|
of data bytes is defined as the total number of bytes transported
|
|
in DOCSIS payloads minus the number of stuff bytes transported in
|
|
DOCSIS payloads.
|
|
This is the 64 bit version of docsIfCmtsDownChnlCtrUsedBytes, and
|
|
will not be accessible to SNMPv1 managers."
|
|
::= { docsIfCmtsDownChannelCounterEntry 5 }
|
|
|
|
|
|
|
|
|
|
-- The following table provides operators with input data appropriate for
|
|
-- calculating upstream channel utilization, and for determining the traffic
|
|
-- characteristics of upstream channels.
|
|
-- Operators may use the docsIfCmtsChannelUtilizationTable, or perform their own
|
|
-- polling of the docsIfCmtsUpChannelCounterTable objects for utilization
|
|
-- determination.
|
|
-- The first four 32 and 64 objects in this table are mandatory. Vendors may
|
|
-- choose to implement the remaining optional objects to provide operators with
|
|
-- finer characterization of upstream channel traffic patterns.
|
|
-- The 32 bit counter objects are included to provide backward compatibility
|
|
-- with SNMPv1 managers, which cannot access 64 bit counter objects.
|
|
|
|
|
|
docsIfCmtsUpChannelCounterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DocsIfCmtsUpChannelCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is implemented at the CMTS to provide upstream
|
|
channel statistics appropriate for channel utilization
|
|
calculations."
|
|
::= { docsIfCmtsObjects 11 }
|
|
|
|
docsIfCmtsUpChannelCounterEntry OBJECT-TYPE
|
|
SYNTAX DocsIfCmtsUpChannelCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of traffic statistics for a single upstream channel.
|
|
For Docsis 2.0 CMTSs, an entry in this table exists for
|
|
each ifEntry with an ifType of docsCableUpstreamChannel (205).
|
|
For Docsis 1.x CMTSs, an entry in this table exists for each
|
|
ifEntry with an ifType of docsCableUpstreamInterface (129)."
|
|
INDEX { ifIndex }
|
|
::= { docsIfCmtsUpChannelCounterTable 1 }
|
|
|
|
DocsIfCmtsUpChannelCounterEntry ::= SEQUENCE {
|
|
docsIfCmtsUpChnlCtrId Integer32,
|
|
docsIfCmtsUpChnlCtrTotalMslots Counter32,
|
|
docsIfCmtsUpChnlCtrUcastGrantedMslots Counter32,
|
|
docsIfCmtsUpChnlCtrTotalCntnMslots Counter32,
|
|
docsIfCmtsUpChnlCtrUsedCntnMslots Counter32,
|
|
docsIfCmtsUpChnlCtrExtTotalMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtUcastGrantedMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtTotalCntnMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtUsedCntnMslots Counter64,
|
|
docsIfCmtsUpChnlCtrCollCntnMslots Counter32,
|
|
docsIfCmtsUpChnlCtrTotalCntnReqMslots Counter32,
|
|
docsIfCmtsUpChnlCtrUsedCntnReqMslots Counter32,
|
|
docsIfCmtsUpChnlCtrCollCntnReqMslots Counter32,
|
|
docsIfCmtsUpChnlCtrTotalCntnReqDataMslots Counter32,
|
|
docsIfCmtsUpChnlCtrUsedCntnReqDataMslots Counter32,
|
|
docsIfCmtsUpChnlCtrCollCntnReqDataMslots Counter32,
|
|
docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots Counter32,
|
|
docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots Counter32,
|
|
docsIfCmtsUpChnlCtrCollCntnInitMaintMslots Counter32,
|
|
docsIfCmtsUpChnlCtrExtCollCntnMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtTotalCntnReqMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtUsedCntnReqMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtCollCntnReqMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots Counter64,
|
|
docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots Counter64
|
|
}
|
|
|
|
|
|
docsIfCmtsUpChnlCtrId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CMTS identification of the upstream channel."
|
|
::= { docsIfCmtsUpChannelCounterEntry 1 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrTotalMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of all minislots
|
|
defined for this upstream logical channel. This count includes
|
|
all IUCs and SIDs, even those allocated to the NULL SID for
|
|
a 2.0 logical channel which is inactive.
|
|
This is the 32 bit version of docsIfCmtsUpChnlCtrExtTotalMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is mandatory."
|
|
::= { docsIfCmtsUpChannelCounterEntry 2 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrUcastGrantedMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of unicast granted
|
|
minislots on the upstream logical channel, regardless of burst
|
|
type. Unicast granted minislots are those in which the CMTS
|
|
assigned bandwidth to any unicast SID on the logical channel.
|
|
This is the 32 bit version of docsIfCmtsUpChnlCtrExtUcastGrantedMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is mandatory."
|
|
::= { docsIfCmtsUpChannelCounterEntry 3 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrTotalCntnMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention minislots
|
|
defined for this upstream logical channel. This count includes
|
|
all minislots assigned to a broadcast or multicast SID on the
|
|
logical channel.
|
|
This is the 32 bit version of docsIfCmtsUpChnlCtrExtTotalCntnMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is mandatory."
|
|
::= { docsIfCmtsUpChannelCounterEntry 4 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrUsedCntnMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention minislots
|
|
utilized on the upstream logical channel. For contention regions,
|
|
utilized minislots are those in which the CMTS correctly received
|
|
an upstream burst from any CM on the upstream logical channel.
|
|
This is the 32 bit version of docsIfCmtsUpChnlCtrExtUsedCntnMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is mandatory."
|
|
::= { docsIfCmtsUpChannelCounterEntry 5 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtTotalMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of all minislots
|
|
defined for this upstream logical channel. This count includes
|
|
all IUCs and SIDs, even those allocated to the NULL SID for
|
|
a 2.0 logical channel which is inactive.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrTotalMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is mandatory."
|
|
::= { docsIfCmtsUpChannelCounterEntry 6 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtUcastGrantedMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of unicast granted
|
|
minislots on the upstream logical channel, regardless of burst
|
|
type. Unicast granted minislots are those in which the CMTS
|
|
assigned bandwidth to any unicast SID on the logical channel.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrUcastGrantedMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is mandatory."
|
|
::= { docsIfCmtsUpChannelCounterEntry 7 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtTotalCntnMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention minislots
|
|
defined for this upstream logical channel. This count includes
|
|
all minislots assigned to a broadcast or multicast SID on the
|
|
logical channel.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrTotalCntnMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is mandatory."
|
|
::= { docsIfCmtsUpChannelCounterEntry 8 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtUsedCntnMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention minislots
|
|
utilized on the upstream logical channel. For contention regions,
|
|
utilized minislots are those in which the CMTS correctly received
|
|
an upstream burst from any CM on the upstream logical channel.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrUsedCntnMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is mandatory."
|
|
::= { docsIfCmtsUpChannelCounterEntry 9 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrCollCntnMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention minislots
|
|
subjected to collisions on the upstream logical channel. For
|
|
contention regions, these are the minislots applicable to bursts
|
|
that the CMTS detected, but could not correctly receive.
|
|
This is the 32 bit version of docsIfCmtsUpChnlCtrExtCollCntnMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
a value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 10 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrTotalCntnReqMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
minislots defined for this upstream logical channel. This count
|
|
includes all minislots for IUC1 assigned to a broadcast or multicast
|
|
SID on the logical channel.
|
|
This is the 32 bit version of docsIfCmtsUpChnlCtrExtTotalCntnReqMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 11 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrUsedCntnReqMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
minislots utilized on this upstream logical channel. This count
|
|
includes all contention minislots for IUC1 applicable to bursts
|
|
that the CMTS correctly received.
|
|
This is the 32 bit version of docsIfCmtsUpChnlCtrExtUsedCntnReqMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 12 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrCollCntnReqMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
minislots subjected to collisions on this upstream logical channel.
|
|
This includes all contention minislots for IUC1 applicable to bursts
|
|
that the CMTS detected, but could not correctly receive.
|
|
This is the 32 bit version of docsIfCmtsUpChnlCtrExtCollCntnReqMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 13 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrTotalCntnReqDataMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
data minislots defined for this upstream logical channel. This count
|
|
includes all minislots for IUC2 assigned to a broadcast or multicast
|
|
SID on the logical channel.
|
|
This is the 32 bit version of
|
|
docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 14 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrUsedCntnReqDataMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
data minislots utilized on this upstream logical channel. This
|
|
includes all contention minislots for IUC2 applicable to bursts
|
|
that the CMTS correctly received.
|
|
This is the 32 bit version of
|
|
docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 15 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrCollCntnReqDataMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
data minislots subjected to collisions on this upstream logical
|
|
channel. This includes all contention minislots for IUC2 applicable
|
|
to bursts that the CMTS detected, but could not correctly receive.
|
|
This is the 32 bit version of
|
|
docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 16 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention initial
|
|
maintenance minislots defined for this upstream logical channel.
|
|
This includes all minislots for IUC3 assigned to a broadcast or
|
|
multicast SID on the logical channel.
|
|
This is the 32 bit version of
|
|
docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 17 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention initial
|
|
maintenance minislots utilized on this upstream logical channel.
|
|
This includes all contention minislots for IUC3 applicable to bursts
|
|
that the CMTS correctly received.
|
|
This is the 32 bit version of
|
|
docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 18 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrCollCntnInitMaintMslots OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention initial
|
|
maintenance minislots subjected to collisions on this upstream
|
|
logical channel. This includes all contention minislots for IUC3
|
|
applicable to bursts that the CMTS detected, but could not correctly
|
|
receive.
|
|
This is the 32 bit version of
|
|
docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots,
|
|
and is included for back compatibility with SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 19 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtCollCntnMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of collision contention
|
|
minislots on the upstream logical channel. For contention regions,
|
|
these are the minislots applicable to bursts that the CMTS detected,
|
|
but could not correctly receive.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrCollCntnMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
a value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 20 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtTotalCntnReqMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
minislots defined for this upstream logical channel. This count
|
|
includes all minislots for IUC1 assigned to a broadcast or multicast
|
|
SID on the logical channel.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrTotalCntnReqMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 21 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtUsedCntnReqMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
minislots utilized on this upstream logical channel. This count
|
|
includes all contention minislots for IUC1 applicable to bursts
|
|
that the CMTS correctly received.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrUsedCntnReqMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 22 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtCollCntnReqMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
minislots subjected to collisions on this upstream logical channel.
|
|
This includes all contention minislots for IUC1 applicable to bursts
|
|
that the CMTS detected, but could not correctly receive.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrCollCntnReqMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 23 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
data minislots defined for this upstream logical channel. This count
|
|
includes all minislots for IUC2 assigned to a broadcast or multicast
|
|
SID on the logical channel.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrTotalCntnReqDataMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 24 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
data minislots utilized on this upstream logical channel. This
|
|
includes all contention minislots for IUC2 applicable to bursts
|
|
that the CMTS correctly received.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrUsedCntnReqDataMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 25 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention request
|
|
data minislots subjected to collisions on this upstream logical
|
|
channel. This includes all contention minislots for IUC2 applicable
|
|
to bursts that the CMTS detected, but could not correctly receive.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrCollCntnReqDataMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 26 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of initial maintenance
|
|
minislots defined for this upstream logical channel. This count
|
|
includes all minislots for IUC3 assigned to a broadcast or multicast
|
|
SID on the logical channel.
|
|
This is the 64 bit version of
|
|
docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 27 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of initial maintenance
|
|
minislots utilized on this upstream logical channel. This
|
|
includes all contention minislots for IUC3 applicable to bursts
|
|
that the CMTS correctly received.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 28 }
|
|
|
|
|
|
docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count, from CMTS initialization, of contention initial
|
|
maintenance minislots subjected to collisions on this upstream
|
|
logical channel. This includes all contention minislots for IUC3
|
|
applicable to bursts that the CMTS detected, but could not correctly
|
|
receive.
|
|
This is the 64 bit version of docsIfCmtsUpChnlCtrCollCntnInitMaintMslots,
|
|
and will not be accessible to SNMPv1 managers.
|
|
Support for this object is optional. If the object is not supported,
|
|
A value of zero is returned."
|
|
::= { docsIfCmtsUpChannelCounterEntry 29 }
|
|
|
|
|
|
|
|
|
|
--
|
|
-- notification group is for future extension.
|
|
--
|
|
|
|
docsIfNotification OBJECT IDENTIFIER ::= { docsIfMib 2 }
|
|
|
|
docsIfConformance OBJECT IDENTIFIER ::= { docsIfMib 3 }
|
|
docsIfCompliances OBJECT IDENTIFIER ::= { docsIfConformance 1 }
|
|
docsIfGroups OBJECT IDENTIFIER ::= { docsIfConformance 2 }
|
|
|
|
-- compliance statements
|
|
|
|
docsIfBasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for devices that implement
|
|
MCNS/DOCSIS compliant Radio Frequency Interfaces."
|
|
|
|
MODULE -- docsIfMib
|
|
|
|
-- unconditionally mandatory groups
|
|
MANDATORY-GROUPS {
|
|
docsIfBasicGroup
|
|
}
|
|
|
|
-- conditionally mandatory group
|
|
GROUP docsIfCmGroup
|
|
DESCRIPTION
|
|
"This group is implemented only in Cable Modems, not in
|
|
Cable Modem Termination Systems."
|
|
-- conditionally mandatory group
|
|
GROUP docsIfCmtsGroup
|
|
DESCRIPTION
|
|
"This group is implemented only in Cable Modem Termination
|
|
Systems, not in Cable Modems."
|
|
|
|
OBJECT docsIfDownChannelFrequency
|
|
WRITE-SYNTAX Integer32 (47000000..862000000)
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write in Cable Modem Termination Systems,
|
|
read-only in Cable Modems.
|
|
A range of 54MHz to 860MHz is appropriate for a cable
|
|
plant using a North American Sub-Split channel plan.
|
|
The spectrum range has been expanded to accommodate
|
|
a lower edge of 47MHz and an upper edge of 862MHz
|
|
for some European channel plans.
|
|
If DOCSIS is extended to cover other types of channel
|
|
plans (and frequency allocations) this object will be
|
|
modified accordingly."
|
|
|
|
OBJECT docsIfDownChannelWidth
|
|
WRITE-SYNTAX Integer32 (6000000 | 8000000)
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"It is conformant to implement this object as read-only.
|
|
In Cable Modems, this object is always implemented as
|
|
read-only. The value of 6 MHz is appropriate for cable
|
|
plants running under NTSC (National Television
|
|
Standards Committee) standards. The value of 8 MHz is
|
|
appropriate for cable plants running under ETSI
|
|
standards. For other regional standards, this
|
|
object will be modified accordingly."
|
|
|
|
OBJECT docsIfDownChannelModulation
|
|
WRITE-SYNTAX INTEGER {
|
|
qam64 (3),
|
|
qam256 (4)
|
|
}
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfDownChannelInterleave
|
|
WRITE-SYNTAX INTEGER {
|
|
taps8Increment16(3),
|
|
taps16Increment8(4),
|
|
taps32Increment4(5),
|
|
taps64Increment2(6),
|
|
taps128Increment1(7),
|
|
taps12increment17(8)
|
|
}
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfDownChannelPower
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelFrequency
|
|
WRITE-SYNTAX Integer32 (5000000..65000000)
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems.
|
|
A range of 5MHz to 42MHz is appropriate for a cable
|
|
plant using a North American Sub-Split channel plan.
|
|
The spectrum range has been expanded to accommodate
|
|
an upper edge of 65MHz for some European channel plans.
|
|
If DOCSIS is extended to cover other types of channel
|
|
plans (and frequency allocations) this object will
|
|
be modified accordingly."
|
|
|
|
OBJECT docsIfUpChannelWidth
|
|
WRITE-SYNTAX Integer32 (200000..6400000)
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems. The above value is appropriate
|
|
for cable plants running under NTSC (National Television
|
|
Standards Committee) standards. If DOCSIS is extended to
|
|
work with other standard (e.g. European standards), this
|
|
object will be modified accordingly."
|
|
|
|
OBJECT docsIfUpChannelModulationProfile
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelSlotSize
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"This object is always read-only in Cable Modems.
|
|
It is compliant to implement this object as read-only
|
|
in Cable Modem Termination Systems."
|
|
|
|
OBJECT docsIfUpChannelRangingBackoffStart
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelRangingBackoffEnd
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelTxBackoffStart
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelTxBackoffEnd
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelScdmaActiveCodes
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"This object is always read-only in Cable Modems. The number of active
|
|
codes when SCDMA is in use must range from 64 to 128, and must be a non-
|
|
Prime value. Providing this range allows for the following features and
|
|
capabilities:
|
|
1) Power management in S-CDMA spreader-on frames (with a 3 dB spread)
|
|
2) Avoidance of code 0
|
|
3) Flexible minislot sizes with and without the use of code 0"
|
|
|
|
OBJECT docsIfUpChannelScdmaCodesPerSlot
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelScdmaFrameSize
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelScdmaHoppingSeed
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"This object is always read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelCloneFrom
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelUpdate
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfUpChannelPreEqEnable
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-create in Cable Modem Termination Systems,
|
|
read-only in Cable Modems."
|
|
|
|
OBJECT docsIfQosProfPriority
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"This object is always read-only in Cable Modems.
|
|
It is compliant to implement this object as read-only
|
|
in Cable Modem Termination Systems."
|
|
|
|
|
|
OBJECT docsIfQosProfPriority
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"This object is always read-only in Cable Modems.
|
|
It is compliant to implement this object as read-only
|
|
in Cable Modem Termination Systems."
|
|
|
|
OBJECT docsIfQosProfMaxUpBandwidth
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"This object is always read-only in Cable Modems.
|
|
It is compliant to implement this object as read-only
|
|
in Cable Modem Termination Systems."
|
|
|
|
OBJECT docsIfQosProfGuarUpBandwidth
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"This object is always read-only in Cable Modems.
|
|
It is compliant to implement this object as read-only
|
|
in Cable Modem Termination Systems."
|
|
|
|
OBJECT docsIfQosProfMaxDownBandwidth
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"This object is always read-only in Cable Modems.
|
|
It is compliant to implement this object as read-only
|
|
in Cable Modem Termination Systems."
|
|
|
|
OBJECT docsIfQosProfBaselinePrivacy
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"This object is always read-only in Cable Modems.
|
|
It is compliant to implement this object as read-only
|
|
in Cable Modem Termination Systems."
|
|
|
|
OBJECT docsIfQosProfStatus
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"This object is always read-only in Cable Modems.
|
|
It is compliant to implement this object as read-only
|
|
in Cable Modem Termination Systems."
|
|
|
|
OBJECT docsIfQosProfMaxTransmitBurst
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"This object is always read-only in Cable Modems.
|
|
It is compliant to implement this object as read-only
|
|
in Cable Modem Termination Systems."
|
|
|
|
OBJECT docsIfCmtsServiceAdminStatus
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"It is compliant to implement this object as read-only."
|
|
|
|
OBJECT docsIfCmtsSyncInterval
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"It is compliant to implement this object as read-only."
|
|
|
|
OBJECT docsIfCmtsUcdInterval
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"It is compliant to implement this object as read-only."
|
|
|
|
OBJECT docsIfCmtsInsertInterval
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"It is compliant to implement this object as read-only."
|
|
|
|
OBJECT docsIfCmtsInvitedRangingAttempts
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"It is compliant to implement this object as read-only."
|
|
|
|
OBJECT docsIfCmtsQosProfilePermissions
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"It is compliant to implement this object as read-only."
|
|
|
|
::= { docsIfCompliances 1 }
|
|
|
|
docsIfBasicGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
docsIfDownChannelId,
|
|
docsIfDownChannelFrequency,
|
|
docsIfDownChannelWidth,
|
|
docsIfDownChannelModulation,
|
|
docsIfDownChannelInterleave,
|
|
docsIfDownChannelPower,
|
|
docsIfDownChannelAnnex,
|
|
docsIfUpChannelId,
|
|
docsIfUpChannelFrequency,
|
|
docsIfUpChannelWidth,
|
|
docsIfUpChannelModulationProfile,
|
|
docsIfUpChannelSlotSize,
|
|
docsIfUpChannelTxTimingOffset,
|
|
docsIfUpChannelRangingBackoffStart,
|
|
docsIfUpChannelRangingBackoffEnd,
|
|
docsIfUpChannelTxBackoffStart,
|
|
docsIfUpChannelTxBackoffEnd,
|
|
docsIfUpChannelScdmaActiveCodes,
|
|
docsIfUpChannelScdmaCodesPerSlot,
|
|
docsIfUpChannelScdmaFrameSize,
|
|
docsIfUpChannelScdmaHoppingSeed,
|
|
docsIfUpChannelType,
|
|
docsIfUpChannelCloneFrom,
|
|
docsIfUpChannelUpdate,
|
|
docsIfUpChannelStatus,
|
|
docsIfUpChannelPreEqEnable,
|
|
docsIfQosProfPriority,
|
|
docsIfQosProfMaxUpBandwidth,
|
|
docsIfQosProfGuarUpBandwidth,
|
|
docsIfQosProfMaxDownBandwidth,
|
|
docsIfQosProfBaselinePrivacy,
|
|
docsIfQosProfStatus,
|
|
docsIfQosProfMaxTransmitBurst,
|
|
docsIfSigQIncludesContention,
|
|
docsIfSigQUnerroreds,
|
|
docsIfSigQCorrecteds,
|
|
docsIfSigQUncorrectables,
|
|
docsIfSigQSignalNoise,
|
|
docsIfSigQMicroreflections,
|
|
docsIfSigQEqualizationData,
|
|
docsIfSigQExtUnerroreds,
|
|
docsIfSigQExtCorrecteds,
|
|
docsIfSigQExtUncorrectables,
|
|
docsIfDocsisBaseCapability
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented in both Cable Modems and
|
|
Cable Modem Termination Systems."
|
|
::= { docsIfGroups 1 }
|
|
|
|
docsIfCmGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
docsIfCmCmtsAddress,
|
|
docsIfCmCapabilities,
|
|
docsIfCmRangingTimeout,
|
|
-- docsIfCmRangingRespTimeout,
|
|
docsIfCmStatusValue,
|
|
docsIfCmStatusCode,
|
|
docsIfCmStatusTxPower,
|
|
docsIfCmStatusResets,
|
|
docsIfCmStatusLostSyncs,
|
|
docsIfCmStatusInvalidMaps,
|
|
docsIfCmStatusInvalidUcds,
|
|
docsIfCmStatusInvalidRangingResponses,
|
|
docsIfCmStatusInvalidRegistrationResponses,
|
|
docsIfCmStatusT1Timeouts,
|
|
docsIfCmStatusT2Timeouts,
|
|
docsIfCmStatusT3Timeouts,
|
|
docsIfCmStatusT4Timeouts,
|
|
docsIfCmStatusRangingAborteds,
|
|
docsIfCmStatusDocsisOperMode,
|
|
docsIfCmStatusModulationType,
|
|
docsIfCmStatusEqualizationData,
|
|
docsIfCmServiceQosProfile,
|
|
docsIfCmServiceTxSlotsImmed,
|
|
docsIfCmServiceTxSlotsDed,
|
|
docsIfCmServiceTxRetries,
|
|
docsIfCmServiceTxExceededs,
|
|
docsIfCmServiceRqRetries,
|
|
docsIfCmServiceRqExceededs,
|
|
docsIfCmServiceExtTxSlotsImmed,
|
|
docsIfCmServiceExtTxSlotsDed
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented in Cable Modems."
|
|
::= { docsIfGroups 2 }
|
|
|
|
docsIfCmtsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
docsIfCmtsCapabilities,
|
|
docsIfCmtsSyncInterval,
|
|
docsIfCmtsUcdInterval,
|
|
docsIfCmtsMaxServiceIds,
|
|
-- docsIfCmtsInsertionInterval,
|
|
docsIfCmtsInvitedRangingAttempts,
|
|
docsIfCmtsInsertInterval,
|
|
docsIfCmtsStatusInvalidRangeReqs,
|
|
docsIfCmtsStatusRangingAborteds,
|
|
docsIfCmtsStatusInvalidRegReqs,
|
|
docsIfCmtsStatusFailedRegReqs,
|
|
docsIfCmtsStatusInvalidDataReqs,
|
|
docsIfCmtsStatusT5Timeouts,
|
|
docsIfCmtsCmStatusMacAddress,
|
|
docsIfCmtsCmStatusDownChannelIfIndex,
|
|
docsIfCmtsCmStatusUpChannelIfIndex,
|
|
docsIfCmtsCmStatusRxPower,
|
|
docsIfCmtsCmStatusTimingOffset,
|
|
docsIfCmtsCmStatusEqualizationData,
|
|
docsIfCmtsCmStatusValue,
|
|
docsIfCmtsCmStatusUnerroreds,
|
|
docsIfCmtsCmStatusCorrecteds,
|
|
docsIfCmtsCmStatusUncorrectables,
|
|
docsIfCmtsCmStatusSignalNoise,
|
|
docsIfCmtsCmStatusMicroreflections,
|
|
docsIfCmtsCmStatusExtUnerroreds,
|
|
docsIfCmtsCmStatusExtCorrecteds,
|
|
docsIfCmtsCmStatusExtUncorrectables,
|
|
docsIfCmtsCmStatusDocsisRegMode,
|
|
docsIfCmtsCmStatusModulationType,
|
|
docsIfCmtsCmStatusInetAddressType,
|
|
docsIfCmtsCmStatusInetAddress,
|
|
docsIfCmtsCmStatusValueLastUpdate,
|
|
docsIfCmtsServiceAdminStatus,
|
|
docsIfCmtsServiceQosProfile,
|
|
docsIfCmtsServiceCreateTime,
|
|
docsIfCmtsServiceInOctets,
|
|
docsIfCmtsServiceInPackets,
|
|
docsIfCmtsServiceNewCmStatusIndex,
|
|
docsIfCmtsModType,
|
|
docsIfCmtsModControl,
|
|
docsIfCmtsModPreambleLen,
|
|
docsIfCmtsModDifferentialEncoding,
|
|
docsIfCmtsModFECErrorCorrection,
|
|
docsIfCmtsModFECCodewordLength,
|
|
docsIfCmtsModScramblerSeed,
|
|
docsIfCmtsModMaxBurstSize,
|
|
docsIfCmtsModGuardTimeSize,
|
|
docsIfCmtsModLastCodewordShortened,
|
|
docsIfCmtsModScrambler,
|
|
docsIfCmtsModByteInterleaverDepth,
|
|
docsIfCmtsModByteInterleaverBlockSize,
|
|
docsIfCmtsModPreambleType,
|
|
docsIfCmtsModTcmErrorCorrectionOn,
|
|
docsIfCmtsModScdmaInterleaverStepSize,
|
|
docsIfCmtsModScdmaSpreaderEnable,
|
|
docsIfCmtsModScdmaSubframeCodes,
|
|
docsIfCmtsModChannelType,
|
|
docsIfCmtsQosProfilePermissions,
|
|
docsIfCmtsCmPtr,
|
|
docsIfCmtsChannelUtilizationInterval,
|
|
docsIfCmtsChannelUtUtilization,
|
|
docsIfCmtsDownChnlCtrTotalBytes,
|
|
docsIfCmtsDownChnlCtrUsedBytes,
|
|
docsIfCmtsDownChnlCtrExtTotalBytes,
|
|
docsIfCmtsDownChnlCtrExtUsedBytes,
|
|
docsIfCmtsUpChnlCtrTotalMslots,
|
|
docsIfCmtsUpChnlCtrUcastGrantedMslots,
|
|
docsIfCmtsUpChnlCtrTotalCntnMslots,
|
|
docsIfCmtsUpChnlCtrUsedCntnMslots,
|
|
docsIfCmtsUpChnlCtrExtTotalMslots,
|
|
docsIfCmtsUpChnlCtrExtUcastGrantedMslots,
|
|
docsIfCmtsUpChnlCtrExtTotalCntnMslots,
|
|
docsIfCmtsUpChnlCtrExtUsedCntnMslots,
|
|
docsIfCmtsUpChnlCtrCollCntnMslots,
|
|
docsIfCmtsUpChnlCtrTotalCntnReqMslots,
|
|
docsIfCmtsUpChnlCtrUsedCntnReqMslots,
|
|
docsIfCmtsUpChnlCtrCollCntnReqMslots,
|
|
docsIfCmtsUpChnlCtrTotalCntnReqDataMslots,
|
|
docsIfCmtsUpChnlCtrUsedCntnReqDataMslots,
|
|
docsIfCmtsUpChnlCtrCollCntnReqDataMslots,
|
|
docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots,
|
|
docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots,
|
|
docsIfCmtsUpChnlCtrCollCntnInitMaintMslots,
|
|
docsIfCmtsUpChnlCtrExtCollCntnMslots,
|
|
docsIfCmtsUpChnlCtrExtTotalCntnReqMslots,
|
|
docsIfCmtsUpChnlCtrExtUsedCntnReqMslots,
|
|
docsIfCmtsUpChnlCtrExtCollCntnReqMslots,
|
|
docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots,
|
|
docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots,
|
|
docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots,
|
|
docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots,
|
|
docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots,
|
|
docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects implemented in Cable Modem Termination
|
|
Systems."
|
|
::= { docsIfGroups 3 }
|
|
|
|
|
|
docsIfObsoleteGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
docsIfCmRangingRespTimeout,
|
|
docsIfCmtsInsertionInterval
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Group of objects obsoleted."
|
|
::= { docsIfGroups 4 }
|
|
|
|
docsIfDeprecatedGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
docsIfQosProfMaxTxBurst,
|
|
docsIfCmtsCmStatusIpAddress,
|
|
docsIfCmtsServiceCmStatusIndex
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Group of objects deprecated."
|
|
::= { docsIfGroups 5 }
|
|
|
|
|
|