- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
7229 lines
260 KiB
Text
7229 lines
260 KiB
Text
--
|
|
-- Dell Remote Access Controller (RAC) and Chassis Management Controller (CMC)
|
|
-- Management Information Base
|
|
--
|
|
-- This MIB is the legacy iDRAC MIB. Changes are no longer made to this MIB
|
|
-- for iDRACs. iDRACs don't support all of the objects and traps defined
|
|
-- in this MIB. There is a new and more extensive iDRAC MIB available for
|
|
-- newer iDRACs (iDRAC7 and newer).
|
|
--
|
|
-- This MIB is also the CMC MIB. Changes are made to this MIB only for CMCs now.
|
|
--
|
|
-- Copyright (c) 2017 Dell Inc.
|
|
--
|
|
-- Last Changed Revision: 19
|
|
-- Last Changed Date: 2017-07-13 03:46:06 -0530 (Thu, 13 Jul 2017)
|
|
-- Text Last Updated: 2017-07-13 03:46:06 -0530 (Thu, 13 Jul 2017)
|
|
--
|
|
|
|
DELL-RAC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises, TimeTicks
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
TRAP-TYPE
|
|
FROM RFC-1215
|
|
DisplayString
|
|
FROM RFC1213-MIB;
|
|
|
|
-- text convention ------------------------------------------------------------------------
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- This data type is used to model textual information taken
|
|
-- from the NVT ASCII character set. By convention, objects
|
|
-- with this syntax are declared as having
|
|
-- SIZE (0..1023)
|
|
-------------------------------------------------------------------------------
|
|
DellString ::= DisplayString (SIZE (0..1023))
|
|
|
|
DellRacType ::= INTEGER
|
|
{
|
|
other(1), -- the DRAC type is not one of the following
|
|
unknown(2), -- the DRAC type is unknown
|
|
dracIII(3), -- Drac III
|
|
era(4), -- ERA
|
|
drac4(5), -- Drac 4
|
|
drac5(6), -- Drac 5
|
|
drac5MC(7), -- Drac 5/MC
|
|
cmc(8), -- CMC
|
|
idrac(9), -- iDRAC
|
|
idrac7monolithic(16), -- iDRAC7 Monolithic
|
|
idrac7modular(17), -- iDRAC7 Modular
|
|
vrtxCMC(18), -- VRTX CMC
|
|
fx2CMC(19), -- FX2 Family CMC
|
|
idrac8monolithic(32), -- iDRAC8 Monolithic
|
|
idrac8modular(33) -- iDRAC8 Modular
|
|
}
|
|
|
|
DellStatus ::= INTEGER
|
|
{
|
|
other(1), -- the status of the object is not one of the following:
|
|
unknown(2), -- the status of the object is unknown
|
|
-- (not known or monitored)
|
|
ok(3), -- the status of the object is ok
|
|
nonCritical(4), -- the status of the object is warning, non-critical
|
|
critical(5), -- the status of the object is critical (failure)
|
|
nonRecoverable(6) -- the status of the object is non-recoverable (dead)
|
|
}
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- DellPowerReading is a string representation of a floating point value,
|
|
-- having exactly 3 digits of precision, and a maximum of 31 characters.
|
|
--
|
|
-- DellChassisPowerIndexRange defines the possible chassis power instances
|
|
-- in this MIB.
|
|
--
|
|
-- DellCMCPSUIndexRange defines the possible CMC Power Supply Unit (PSU)
|
|
-- instances, per chassis power instance, in this MIB.
|
|
--
|
|
-- DellCMCPSUCapable is an enumeration of PSU presence and/or monitoring
|
|
-- capabilities.
|
|
--
|
|
-- DellTemperatureReading is an integer value, expressed in degrees Celsius.
|
|
-------------------------------------------------------------------------------
|
|
DellPowerReading ::= DisplayString (SIZE (0..32))
|
|
|
|
DellCMCPowerIndexRange ::= INTEGER (1..1)
|
|
|
|
DellCMCPSUIndexRange ::= INTEGER (1..6)
|
|
|
|
DellCMCPSUCapable ::= INTEGER
|
|
{
|
|
absent(1), -- power supply is not present
|
|
none(2), -- no power monitoring abilities
|
|
basic(3) -- basic power monitoring abilities
|
|
}
|
|
|
|
DellTemperatureReading ::= INTEGER
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- DellTimestamp is defined in the displayable format:
|
|
--
|
|
-- yyyymmddHHMMSS.uuuuuuDooo
|
|
--
|
|
-- where yyyy is the year, mm is the month number, dd is the day of the month,
|
|
-- HHMMSS are the hours, minutes and seconds, respectively, uuuuuu is the
|
|
-- number of microseconds, D is the UTC offset direction, and ooo is the
|
|
-- offset from UTC, in minutes.
|
|
--
|
|
-- Note: D is a plus (+) sign if east of UTC, and a minus (-) if west of UTC.
|
|
--
|
|
-- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT
|
|
-- would be represented as: 19940525133015.000000-300
|
|
-------------------------------------------------------------------------------
|
|
DellTimestamp ::= DisplayString (SIZE (26))
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- DellCMCServerIndexRange defines the possible chassis server instances
|
|
-- in this MIB.
|
|
--
|
|
-- DellCMCServerCapable is an enumeration of server presence and/or monitoring
|
|
-- capabilities.
|
|
-------------------------------------------------------------------------------
|
|
DellCMCServerIndexRange ::= INTEGER (1..32)
|
|
|
|
DellCMCServerCapable ::= INTEGER
|
|
{
|
|
absent(1), -- server is not present
|
|
none(2), -- no server monitoring abilities
|
|
basic(3), -- basic server monitoring abilities
|
|
off(4) -- server is powered off
|
|
}
|
|
|
|
DellCMCServerStorageMode ::= INTEGER
|
|
{
|
|
notApplicable(1), -- not applicable to server
|
|
joined(2), -- storage mode is Joined
|
|
splitDualHost(3), -- storage mode is Split Dual Host
|
|
splitSingleHost(4), -- storage mode is Split Single Host
|
|
unknown(99) -- storage mode is unknown
|
|
}
|
|
|
|
DellCMCServerIntrusionState ::= INTEGER
|
|
{
|
|
notApplicable(1), -- not applicable to server
|
|
closed(2), -- intrusion state is Closed
|
|
open(3), -- intrusion state is Open
|
|
unknown(99) -- intrusion state is unknown
|
|
}
|
|
|
|
|
|
-- MIB Objects and Tables --------------------------------------------------------
|
|
|
|
dell OBJECT IDENTIFIER ::= { enterprises 674 }
|
|
server3 OBJECT IDENTIFIER ::= { dell 10892 }
|
|
drsOutofBandGroup OBJECT IDENTIFIER ::= { server3 2 }
|
|
drsInformationGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 1 }
|
|
drsProductInfoGroup OBJECT IDENTIFIER ::= { drsInformationGroup 1 }
|
|
drsFirmwareGroup OBJECT IDENTIFIER ::= { drsInformationGroup 2 }
|
|
|
|
drsStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 2 }
|
|
|
|
drsChassisStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 3 }
|
|
drsStatusNowGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 1 }
|
|
drsStatusPrevGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 2 }
|
|
drsStatusChangeGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 3 }
|
|
|
|
drsChassisPowerGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 4 }
|
|
|
|
DrsCMCPowerTableEntry ::= SEQUENCE
|
|
{
|
|
drsChassisIndex DellCMCPowerIndexRange,
|
|
drsPotentialPower DellPowerReading,
|
|
drsIdlePower DellPowerReading,
|
|
drsMaxPowerSpecification DellPowerReading,
|
|
drsPowerSurplus DellPowerReading,
|
|
drsKWhCumulative DellPowerReading,
|
|
drsKWhCumulativeTime DellTimestamp,
|
|
drsWattsPeakUsage DellPowerReading,
|
|
drsWattsPeakTime DellTimestamp,
|
|
drsWattsMinUsage DellPowerReading,
|
|
drsWattsMinTime DellTimestamp,
|
|
drsWattsResetTime DellTimestamp,
|
|
drsWattsReading DellPowerReading,
|
|
drsAmpsReading DellPowerReading
|
|
}
|
|
|
|
DrsCMCPSUTableEntry ::= SEQUENCE
|
|
{
|
|
drsPSUChassisIndex DellCMCPowerIndexRange,
|
|
drsPSUIndex DellCMCPSUIndexRange,
|
|
drsPSULocation DellString,
|
|
drsPSUMonitoringCapable DellCMCPSUCapable,
|
|
drsPSUVoltsReading DellPowerReading,
|
|
drsPSUAmpsReading DellPowerReading,
|
|
drsPSUWattsReading DellPowerReading
|
|
}
|
|
|
|
drsChassisServerGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 5 }
|
|
|
|
DrsCMCServerTableEntry ::= SEQUENCE
|
|
{
|
|
drsServerIndex DellCMCServerIndexRange,
|
|
drsServerMonitoringCapable DellCMCServerCapable,
|
|
drsServerServiceTag DellString,
|
|
drsServerSlotName DellString,
|
|
drsServerSlotNumber DellString,
|
|
drsServerNodeID DellString,
|
|
drsServerModel DellString,
|
|
drsServerAssetTag DellString,
|
|
drsServerNumStorageControllers INTEGER,
|
|
drsServerStorageMode DellCMCServerStorageMode,
|
|
drsServerIntrusionState DellCMCServerIntrusionState,
|
|
drsServerAssignedServerSlots DellString
|
|
}
|
|
|
|
-- Storage details start
|
|
storageDetailsGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 6 }
|
|
software OBJECT IDENTIFIER ::= { storageDetailsGroup 1 }
|
|
storageManagement OBJECT IDENTIFIER ::= { software 20 }
|
|
physicalDevices OBJECT IDENTIFIER ::= { storageManagement 130 }
|
|
logicalDevices OBJECT IDENTIFIER ::= { storageManagement 140 }
|
|
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Textual Conventions
|
|
------------------------------------------------------------------------------
|
|
|
|
FQDDString ::= DisplayString (SIZE (0..512))
|
|
|
|
ObjectStatusEnum ::= INTEGER {
|
|
other(1), -- the status of the object is not one of the
|
|
-- following:
|
|
unknown(2), -- the status of the object is unknown
|
|
-- (not known or monitored)
|
|
ok(3), -- the status of the object is ok
|
|
nonCritical(4), -- the status of the object is warning, non-critical
|
|
critical(5), -- the status of the object is critical (failure)
|
|
nonRecoverable(6) -- the status of the object is non-recoverable (dead)
|
|
}
|
|
BooleanType ::= INTEGER (0..1) -- 0 = FALSE, 1 = TRUE
|
|
|
|
|
|
-- Storage details end
|
|
|
|
|
|
drsCMCAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 20 }
|
|
drsChassisAlertVariables OBJECT IDENTIFIER ::= { drsCMCAlertGroup 10 }
|
|
drsCMCAlert2Group OBJECT IDENTIFIER ::= { drsOutofBandGroup 21 }
|
|
drsChassisAlert2Variables OBJECT IDENTIFIER ::= { drsCMCAlert2Group 10 }
|
|
|
|
drsAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 5000 }
|
|
drsAlertVariables OBJECT IDENTIFIER ::= { drsAlertGroup 10 }
|
|
|
|
|
|
-- Variables and Traps ------------------------------------------------------------------------
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: product information
|
|
-------------------------------------------------------------------------------
|
|
|
|
drsProductName OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0001 This attribute defines the product name of a chassis management controller."
|
|
::= { drsProductInfoGroup 1 }
|
|
|
|
drsProductShortName OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0002 This attribute defines the short product name of a chassis management controller. "
|
|
::= { drsProductInfoGroup 2 }
|
|
|
|
drsProductDescription OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0003 This attribute defines the product description of a chassis management controller. "
|
|
::= { drsProductInfoGroup 3 }
|
|
|
|
drsProductManufacturer OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. "
|
|
::= { drsProductInfoGroup 4 }
|
|
|
|
drsProductVersion OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0005 This attribute defines the product version of a chassis management controller. "
|
|
::= { drsProductInfoGroup 5 }
|
|
|
|
drsChassisServiceTag OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0007 This attribute defines the Service Tag of the chassis. "
|
|
::= { drsProductInfoGroup 6 }
|
|
|
|
drsProductURL OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. "
|
|
::= { drsProductInfoGroup 7 }
|
|
|
|
drsProductChassisAssetTag OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0008 This attribute defines the Asset Tag of the chassis. "
|
|
::= { drsProductInfoGroup 8 }
|
|
|
|
drsProductChassisLocation OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0009 This attribute defines the location of the chassis. "
|
|
::= { drsProductInfoGroup 9 }
|
|
|
|
drsProductChassisName OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0010 This attribute defines the name of the chassis. "
|
|
::= { drsProductInfoGroup 10 }
|
|
|
|
drsSystemServiceTag OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0011 This attribute defines the service tag of a system. "
|
|
::= { drsProductInfoGroup 11 }
|
|
|
|
drsProductSystemAssetTag OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0012 This attribute defines the asset tag of a system. "
|
|
::= { drsProductInfoGroup 12 }
|
|
|
|
drsProductSystemSlot OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0013 This attribute defines the slot number of a CMC. "
|
|
::= { drsProductInfoGroup 13 }
|
|
|
|
drsProductType OBJECT-TYPE
|
|
SYNTAX DellRacType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0014 This attribute defines type of a remote access card "
|
|
::= { drsProductInfoGroup 14 }
|
|
|
|
drsProductChassisDataCenter OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0015 This attribute defines the Data Center locator of the chassis. "
|
|
::= { drsProductInfoGroup 15 }
|
|
|
|
drsProductChassisAisle OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0016 This attribute defines the Aisle locator of the chassis. "
|
|
::= { drsProductInfoGroup 16 }
|
|
|
|
drsProductChassisRack OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0017 This attribute defines the Rack locator of the chassis. "
|
|
::= { drsProductInfoGroup 17 }
|
|
|
|
drsProductChassisRackSlot OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. "
|
|
::= { drsProductInfoGroup 18 }
|
|
|
|
drsProductChassisModel OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0019 This attribute defines the Model of the chassis."
|
|
::= { drsProductInfoGroup 19 }
|
|
|
|
drsProductChassisExpressServiceCode OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0020 This attribute defines the Express Service Code of the chassis."
|
|
::= { drsProductInfoGroup 20 }
|
|
|
|
drsProductChassisSystemID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0021 This attribute defines the System ID of the chassis."
|
|
::= { drsProductInfoGroup 21 }
|
|
|
|
drsProductChassisSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0001.0022 This attribute defines the size of the
|
|
chassis in rack units (U). A U is a standard unit of
|
|
measure for the height of a rack or rack-mountable component."
|
|
::= { drsProductInfoGroup 22 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: firmware
|
|
-------------------------------------------------------------------------------
|
|
|
|
drsFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0002.0001 This attribute defines the firmware version of chassis management controller 1."
|
|
::= { drsFirmwareGroup 1 }
|
|
|
|
drsiKVMFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0002.0002 This attribute defines the firmware version of the iKVM. "
|
|
::= { drsFirmwareGroup 2 }
|
|
|
|
drsFirmwareVersion2 OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0001.0002.0003 This attribute defines the firmware version of chassis management controller 2."
|
|
::= { drsFirmwareGroup 3 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: chassis status
|
|
-------------------------------------------------------------------------------
|
|
|
|
drsGlobalSystemStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0002.0001.0001 This attribute defines the overall chassis status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusGroup 1 }
|
|
|
|
drsGlobalCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0001 This attribute defines the overall chassis status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusNowGroup 1 }
|
|
|
|
drsIOMCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0002 This attribute defines the IOM subsystem status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusNowGroup 2 }
|
|
|
|
drsKVMCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0003 This attribute defines the iKVM subsystem health status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusNowGroup 3 }
|
|
|
|
drsRedCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0004 This attribute defines the Redundancy status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusNowGroup 4 }
|
|
|
|
drsPowerCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0005 This attribute defines the power subsystem health status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusNowGroup 5 }
|
|
|
|
drsFanCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0006 This attribute defines the Fan subsystem health status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusNowGroup 6 }
|
|
|
|
drsBladeCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0007 This attribute defines the Blade subsystem health status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusNowGroup 7 }
|
|
|
|
drsTempCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor subsystem health status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusNowGroup 8 }
|
|
|
|
drsCMCCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusNowGroup 9 }
|
|
|
|
drsChassisFrontPanelAmbientTemperature OBJECT-TYPE
|
|
SYNTAX DellTemperatureReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0010 This attribute defines the ambient temperature
|
|
reading (in degrees Celsius) for the chassis front panel controller."
|
|
::= { drsStatusNowGroup 10 }
|
|
|
|
drsCMCAmbientTemperature OBJECT-TYPE
|
|
SYNTAX DellTemperatureReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0011 This attribute defines the ambient temperature
|
|
reading (in degrees Celsius) for the chassis management card."
|
|
::= { drsStatusNowGroup 11 }
|
|
|
|
drsCMCProcessorTemperature OBJECT-TYPE
|
|
SYNTAX DellTemperatureReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0012 This attribute defines the temperature reading
|
|
(in degrees Celsius) for the chassis management card processor."
|
|
::= { drsStatusNowGroup 12 }
|
|
|
|
drsGlobalPrevStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0002.0001 This attribute defines the previous chassis status
|
|
recorded by the chassis management card."
|
|
::= { drsStatusPrevGroup 1 }
|
|
|
|
drsIOMPrevStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0002.0002 This attribute defines the previous IOM subsystem status
|
|
recorded by the chassis management card."
|
|
::= { drsStatusPrevGroup 2 }
|
|
|
|
drsKVMPrevStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0002.0003 This attribute defines the previous iKVM subsystem health status
|
|
recorded by the chassis management card."
|
|
::= { drsStatusPrevGroup 3 }
|
|
|
|
drsRedPrevStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0002.0004 This attribute defines the previous Redundancy status
|
|
recorded by the chassis management card."
|
|
::= { drsStatusPrevGroup 4 }
|
|
|
|
drsPowerPrevStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0002.0005 This attribute defines the previous power subsystem health status
|
|
recorded by the chassis management card."
|
|
::= { drsStatusPrevGroup 5 }
|
|
|
|
drsFanPrevStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0002.0006 This attribute defines the previous Fan health status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusPrevGroup 6 }
|
|
|
|
drsBladePrevStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0002.0007 This attribute defines the previous Blade subsystem health status
|
|
recorded by the chassis management card."
|
|
::= { drsStatusPrevGroup 7 }
|
|
|
|
drsTempPrevStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor health status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusPrevGroup 8 }
|
|
|
|
drsCMCPrevStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status
|
|
being monitored by the chassis management card."
|
|
::= { drsStatusPrevGroup 9 }
|
|
|
|
drsGlobalChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0003.0001 This attribute defines the timestamp of the most recent
|
|
global status change."
|
|
::= { drsStatusChangeGroup 1 }
|
|
|
|
drsIOMChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0003.0002 This attribute defines the timestamp of the most recent
|
|
IOM status change."
|
|
::= { drsStatusChangeGroup 2 }
|
|
|
|
drsKVMChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0003.0003 This attribute defines the timestamp of the most recent
|
|
iKVM status change."
|
|
::= { drsStatusChangeGroup 3 }
|
|
|
|
drsRedChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0003.0004 This attribute defines the timestamp of the most recent
|
|
Redundancy status change."
|
|
::= { drsStatusChangeGroup 4 }
|
|
|
|
drsPowerChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0003.0005 This attribute defines the timestamp of the most recent
|
|
power health status change."
|
|
::= { drsStatusChangeGroup 5 }
|
|
|
|
drsFanChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0003.0006 This attribute defines the timestamp of the most recent
|
|
Fan health status change."
|
|
::= { drsStatusChangeGroup 6 }
|
|
|
|
drsBladeChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0003.0007 This attribute defines the timestamp of the most recent
|
|
Blade health status change."
|
|
::= { drsStatusChangeGroup 7 }
|
|
|
|
drsTempChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0003.0008 This attribute defines the timestamp of the most recent
|
|
Temp Sensor health status change."
|
|
::= { drsStatusChangeGroup 8 }
|
|
|
|
drsCMCChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0003.0003.0009 This attribute defines the timestamp of the most recent
|
|
CMC health status change."
|
|
::= { drsStatusChangeGroup 9 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: chassis power
|
|
-------------------------------------------------------------------------------
|
|
|
|
drsCMCPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DrsCMCPowerTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001 This object defines the CMC power table."
|
|
::= { drsChassisPowerGroup 1 }
|
|
|
|
drsCMCPowerTableEntry OBJECT-TYPE
|
|
SYNTAX DrsCMCPowerTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001 This object defines the CMC power table entry."
|
|
INDEX { drsChassisIndex }
|
|
::= { drsCMCPowerTable 1 }
|
|
|
|
drsCMCPSUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DrsCMCPSUTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0002 This object defines the CMC PSU table."
|
|
::= { drsChassisPowerGroup 2 }
|
|
|
|
drsCMCPSUTableEntry OBJECT-TYPE
|
|
SYNTAX DrsCMCPSUTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0002.0001 This object defines the CMC PSU table entry."
|
|
INDEX { drsPSUChassisIndex, drsPSUIndex }
|
|
::= { drsCMCPSUTable 1 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- table: CMC power information
|
|
-------------------------------------------------------------------------------
|
|
|
|
drsChassisIndex OBJECT-TYPE
|
|
SYNTAX DellCMCPowerIndexRange
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0001 This attribute defines the index
|
|
(one-based) of the associated chassis."
|
|
::= { drsCMCPowerTableEntry 1 }
|
|
|
|
drsPotentialPower OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0002 This attribute defines the power (in Watts) required by
|
|
the chassis infrastructure, plus the sum of the maximum power requirements
|
|
for all currently powered-on servers."
|
|
::= { drsCMCPowerTableEntry 2 }
|
|
|
|
drsIdlePower OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0003 This attribute defines the power (in Watts) required by
|
|
the chassis infrastructure, plus the sum of the minimum power requirements
|
|
for all currently powered-on servers."
|
|
::= { drsCMCPowerTableEntry 3 }
|
|
|
|
drsMaxPowerSpecification OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0004 This attribute defines the power limit (in Watts)
|
|
at which server throttling will take place."
|
|
::= { drsCMCPowerTableEntry 4 }
|
|
|
|
|
|
drsPowerSurplus OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0005 This attribute defines the power surplus (in Watts)
|
|
remaining above the drsPotentialPower reading."
|
|
::= { drsCMCPowerTableEntry 5 }
|
|
|
|
drsKWhCumulative OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0006 This attribute defines the cumulative chassis power
|
|
usage (in KWh) since last reset."
|
|
::= { drsCMCPowerTableEntry 6 }
|
|
|
|
drsKWhCumulativeTime OBJECT-TYPE
|
|
SYNTAX DellTimestamp
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0007 This attribute defines the timestamp of the most recent
|
|
chassis power accumulator reset."
|
|
::= { drsCMCPowerTableEntry 7 }
|
|
|
|
drsWattsPeakUsage OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0008 This attribute defines the chassis peak power
|
|
usage (in Watts) since last reset."
|
|
::= { drsCMCPowerTableEntry 8 }
|
|
|
|
drsWattsPeakTime OBJECT-TYPE
|
|
SYNTAX DellTimestamp
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0009 This attribute defines the timestamp of the most recent
|
|
chassis peak power usage."
|
|
::= { drsCMCPowerTableEntry 9 }
|
|
|
|
drsWattsMinUsage OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0010 This attribute defines the chassis mimimum power
|
|
usage (in Watts) since last reset."
|
|
::= { drsCMCPowerTableEntry 10 }
|
|
|
|
drsWattsMinTime OBJECT-TYPE
|
|
SYNTAX DellTimestamp
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0011 This attribute defines the timestamp of the most recent
|
|
chassis minimum power usage."
|
|
::= { drsCMCPowerTableEntry 11 }
|
|
|
|
drsWattsResetTime OBJECT-TYPE
|
|
SYNTAX DellTimestamp
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0012 This attribute defines the timestamp of the most recent
|
|
reset of the chassis min/peak Watts readings."
|
|
::= { drsCMCPowerTableEntry 12 }
|
|
|
|
drsWattsReading OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0013 This attribute defines the instantaneous chassis power
|
|
usage (in Watts)."
|
|
::= { drsCMCPowerTableEntry 13 }
|
|
|
|
drsAmpsReading OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0001.0001.0014 This attribute defines the instantaneous chassis current
|
|
usage (in Watts)."
|
|
::= { drsCMCPowerTableEntry 14 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- table: CMC PSU info
|
|
-------------------------------------------------------------------------------
|
|
|
|
drsPSUChassisIndex OBJECT-TYPE
|
|
SYNTAX DellCMCPowerIndexRange
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0002.0001.0001 This attribute defines the index
|
|
(one-based) of the associated chassis."
|
|
::= { drsCMCPSUTableEntry 1 }
|
|
|
|
drsPSUIndex OBJECT-TYPE
|
|
SYNTAX DellCMCPSUIndexRange
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0002.0001.0002 This attribute defines the index
|
|
(one-based) of the associated CMC PSU."
|
|
::= { drsCMCPSUTableEntry 2 }
|
|
|
|
drsPSULocation OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0002.0001.0003 This attribute defines the location
|
|
of the CMC PSU."
|
|
::= { drsCMCPSUTableEntry 3 }
|
|
|
|
drsPSUMonitoringCapable OBJECT-TYPE
|
|
SYNTAX DellCMCPSUCapable
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0002.0001.0004 This attribute defines the PSU Monitoring
|
|
capabilities, or the absence of a PSU in this location."
|
|
::= { drsCMCPSUTableEntry 4 }
|
|
|
|
drsPSUVoltsReading OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0002.0001.0005 This attribute defines the instantaneous
|
|
PSU Voltage reading."
|
|
::= { drsCMCPSUTableEntry 5 }
|
|
|
|
drsPSUAmpsReading OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0002.0001.0006 This attribute defines the instantaneous
|
|
PSU Current reading."
|
|
::= { drsCMCPSUTableEntry 6 }
|
|
|
|
drsPSUWattsReading OBJECT-TYPE
|
|
SYNTAX DellPowerReading
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0004.0002.0001.0007 This attribute defines the instantaneous
|
|
PSU Wattage reading."
|
|
::= { drsCMCPSUTableEntry 7 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: chassis servers
|
|
-------------------------------------------------------------------------------
|
|
|
|
drsCMCServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DrsCMCServerTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001 This object defines the CMC server table."
|
|
::= { drsChassisServerGroup 1 }
|
|
|
|
drsCMCServerTableEntry OBJECT-TYPE
|
|
SYNTAX DrsCMCServerTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001 This object defines the CMC server table entry."
|
|
INDEX { drsServerIndex }
|
|
::= { drsCMCServerTable 1 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- table: CMC Server info
|
|
-------------------------------------------------------------------------------
|
|
|
|
drsServerIndex OBJECT-TYPE
|
|
SYNTAX DellCMCServerIndexRange
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0001 This attribute defines the index
|
|
(one-based) of the associated CMC server."
|
|
::= { drsCMCServerTableEntry 1 }
|
|
|
|
drsServerMonitoringCapable OBJECT-TYPE
|
|
SYNTAX DellCMCServerCapable
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0002 This attribute defines the server monitoring
|
|
capabilities, or the absence of a server in this location."
|
|
::= { drsCMCServerTableEntry 2 }
|
|
|
|
drsServerServiceTag OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0003 This attribute defines the Service Tag
|
|
of the CMC server."
|
|
::= { drsCMCServerTableEntry 3 }
|
|
|
|
drsServerSlotName OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0004 This attribute defines the Slot Name
|
|
of the CMC server."
|
|
::= { drsCMCServerTableEntry 4 }
|
|
|
|
drsServerSlotNumber OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0005 This attribute defines the Chassis
|
|
Slot Number of the CMC server."
|
|
::= { drsCMCServerTableEntry 5 }
|
|
|
|
drsServerNodeID OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0006 This attribute defines the Node ID
|
|
of the CMC server. The Node ID provides a unique identifier
|
|
for the server."
|
|
::= { drsCMCServerTableEntry 6 }
|
|
|
|
drsServerModel OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0007 This attribute defines the Model
|
|
of the CMC server."
|
|
::= { drsCMCServerTableEntry 7 }
|
|
|
|
drsServerAssetTag OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0008 This attribute defines the Asset Tag
|
|
of the CMC server."
|
|
::= { drsCMCServerTableEntry 8 }
|
|
|
|
drsServerNumStorageControllers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0009 This attribute defines the number of
|
|
storage controllers on the storage sled. The value
|
|
will be zero if this is not a storage sled."
|
|
::= { drsCMCServerTableEntry 9 }
|
|
|
|
drsServerStorageMode OBJECT-TYPE
|
|
SYNTAX DellCMCServerStorageMode
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0010 This attribute defines the Storage
|
|
Mode of the storage sled."
|
|
::= { drsCMCServerTableEntry 10 }
|
|
|
|
drsServerIntrusionState OBJECT-TYPE
|
|
SYNTAX DellCMCServerIntrusionState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0011 This attribute defines the Intrusion
|
|
State of the CMC server if supported by the server."
|
|
::= { drsCMCServerTableEntry 11 }
|
|
|
|
drsServerAssignedServerSlots OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0005.0001.0001.0012 This attribute defines the the server
|
|
slots to which a storage sled is assigned. If this is
|
|
a storage sled that is assigned to one more or more
|
|
server slots, the value will be a comma-separated list
|
|
of one or more server slot names. If the storage sled
|
|
is not assigned to a server slot, the value will be an
|
|
empty string. If this is not a storage sled, the value
|
|
will be N/A."
|
|
::= { drsCMCServerTableEntry 12 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Storage Details Group
|
|
--
|
|
-- OID Format: 1.3.6.1.4.1.674.10892.5.5
|
|
-------------------------------------------------------------------------------
|
|
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Battery Table
|
|
--
|
|
-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.<a>.<i1>
|
|
-------------------------------------------------------------------------------
|
|
|
|
BatteryTableEntry ::=SEQUENCE {
|
|
batteryNumber INTEGER,
|
|
batteryState INTEGER,
|
|
batteryComponentStatus ObjectStatusEnum,
|
|
batteryPredictedCapacity INTEGER,
|
|
batteryFQDD DisplayString,
|
|
batteryDisplayName DisplayString
|
|
}
|
|
|
|
batteryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BatteryTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of managed batteries. The number of
|
|
entries is related to number of Batteries
|
|
discovered in the system. The maximum number of entries
|
|
is implementation dependent.
|
|
Note: The properties in this table may not be applicable to all
|
|
entries.
|
|
"
|
|
::= { physicalDevices 15 }
|
|
|
|
batteryTableEntry OBJECT-TYPE
|
|
SYNTAX BatteryTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the battery table. A row in this table cannot be
|
|
created or deleted by SNMP operations on columns of the table.
|
|
"
|
|
INDEX { batteryNumber }
|
|
::= { batteryTable 1 }
|
|
|
|
batteryNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Instance number of this battery entry.
|
|
"
|
|
::= { batteryTableEntry 1 }
|
|
|
|
batteryState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
ready(2),
|
|
failed(3),
|
|
degraded(4),
|
|
missing(5),
|
|
charging(6),
|
|
belowThreshold(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current state of battery.
|
|
Possible values:
|
|
1: The current state could not be determined.
|
|
2: The battery is operating normally.
|
|
3: The battery has failed and needs to be replaced.
|
|
4: The battery temperature is high or charge level is depleting.
|
|
5: The battery is missing or not detected.
|
|
6: The battery is undergoing the re-charge phase.
|
|
7: The battery voltage or charge level is below the threshold.
|
|
"
|
|
::= { batteryTableEntry 4 }
|
|
|
|
batteryComponentStatus OBJECT-TYPE
|
|
SYNTAX ObjectStatusEnum
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the battery itself without the
|
|
propagation of any contained component status.
|
|
Possible values:
|
|
1: Other
|
|
2: Unknown
|
|
3: OK
|
|
4: Non-critical
|
|
5: Critical
|
|
6: Non-recoverable"
|
|
::= { batteryTableEntry 6 }
|
|
|
|
batteryPredictedCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
failed(2),
|
|
ready(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This entry is obsolete. Use the batteryComponentStatus or
|
|
batteryState instead.
|
|
"
|
|
::= { batteryTableEntry 10 }
|
|
|
|
batteryFQDD OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery's Fully Qualified Device Descriptor (FQDD) as
|
|
represented in Storage Management.
|
|
"
|
|
::= { batteryTableEntry 20 }
|
|
|
|
batteryDisplayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery's friendly FQDD as represented in Storage Management."
|
|
::= { batteryTableEntry 21 }
|
|
|
|
|
|
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Controller Table
|
|
--
|
|
-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.<a>.<i1>
|
|
-------------------------------------------------------------------------------
|
|
|
|
ControllerTableEntry ::=SEQUENCE {
|
|
controllerNumber INTEGER,
|
|
controllerName DisplayString,
|
|
controllerRebuildRate INTEGER,
|
|
controllerFWVersion DisplayString,
|
|
controllerCacheSizeInMB INTEGER,
|
|
controllerRollUpStatus ObjectStatusEnum,
|
|
controllerComponentStatus ObjectStatusEnum,
|
|
controllerDriverVersion DisplayString,
|
|
controllerPCISlot DisplayString,
|
|
controllerReconstructRate INTEGER,
|
|
controllerPatrolReadRate INTEGER,
|
|
controllerBGIRate INTEGER,
|
|
controllerCheckConsistencyRate INTEGER,
|
|
controllerPatrolReadMode INTEGER,
|
|
controllerPatrolReadState INTEGER,
|
|
controllerPersistentHotSpare BooleanType,
|
|
controllerSpinDownUnconfiguredDrives BooleanType,
|
|
controllerSpinDownHotSpareDrives BooleanType,
|
|
controllerSpinDownTimeInterval INTEGER,
|
|
controllerPreservedCache BooleanType,
|
|
controllerCheckConsistencyMode INTEGER,
|
|
controllerCopyBackMode INTEGER,
|
|
controllerSecurityStatus INTEGER,
|
|
controllerEncryptionKeyPresent BooleanType,
|
|
controllerEncryptionCapability INTEGER,
|
|
controllerLoadBalanceSetting INTEGER,
|
|
controllerMaxCapSpeed INTEGER,
|
|
controllerSASAddress DisplayString,
|
|
controllerFQDD FQDDString,
|
|
controllerDisplayName DisplayString,
|
|
controllerT10PICapability INTEGER,
|
|
controllerRAID10UnevenSpansSupported BooleanType,
|
|
controllerEnhancedAutoImportForeignConfigMode INTEGER,
|
|
controllerBootModeSupported BooleanType,
|
|
controllerBootMode INTEGER,
|
|
controllerHighAvailabilityMode INTEGER,
|
|
controllerPeerController FQDDString,
|
|
controllerEncryptionKeyIdentifier DisplayString
|
|
}
|
|
|
|
controllerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ControllerTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of managed RAID controllers. The number of entries
|
|
is related to number of RAID controllers discovered in the
|
|
system. The maximum number of entries is implementation dependent.
|
|
Note: The properties in this table may not be applicable to all
|
|
entries.
|
|
"
|
|
::= { physicalDevices 1 }
|
|
|
|
controllerTableEntry OBJECT-TYPE
|
|
SYNTAX ControllerTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the table of RAID controllers. A row in this table
|
|
cannot be created or deleted by SNMP operations on columns of
|
|
the table."
|
|
INDEX { controllerNumber }
|
|
::= { controllerTable 1 }
|
|
|
|
controllerNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Instance number of this controller entry."
|
|
::= { controllerTableEntry 1 }
|
|
|
|
|
|
controllerName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The controller's name as represented in Storage Management.
|
|
"
|
|
::= { controllerTableEntry 2 }
|
|
|
|
controllerRebuildRate OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rebuild rate is the percentage of the controller's
|
|
resources dedicated to rebuilding a failed disk when a rebuild
|
|
is necessary.
|
|
"
|
|
::= { controllerTableEntry 7 }
|
|
|
|
controllerFWVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The controller's current firmware version.
|
|
"
|
|
::= { controllerTableEntry 8 }
|
|
|
|
controllerCacheSizeInMB OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The controller's current amount of cache memory in megabytes.
|
|
"
|
|
::= { controllerTableEntry 9 }
|
|
|
|
controllerRollUpStatus OBJECT-TYPE
|
|
SYNTAX ObjectStatusEnum
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Severity of the controller state.
|
|
This is the combined status of the controller and its components.
|
|
Possible values:
|
|
1: Other.
|
|
2: Unknown.
|
|
3: OK
|
|
4: Non-critical
|
|
5: Critical.
|
|
6: Non-recoverable.
|
|
"
|
|
::= { controllerTableEntry 37 }
|
|
|
|
controllerComponentStatus OBJECT-TYPE
|
|
SYNTAX ObjectStatusEnum
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the controller itself without the
|
|
propagation of any contained component status.
|
|
Possible values:
|
|
1: Other
|
|
2: Unknown
|
|
3: OK
|
|
4: Non-critical
|
|
5: Critical
|
|
6: Non-recoverable"
|
|
::= { controllerTableEntry 38 }
|
|
|
|
controllerDriverVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Currently installed driver version for this controller on the host.
|
|
"
|
|
::= { controllerTableEntry 41 }
|
|
|
|
controllerPCISlot OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The PCI slot on the server where the controller is seated. This
|
|
data is not reported for embedded or integrated controllers,
|
|
"
|
|
::= { controllerTableEntry 42 }
|
|
|
|
controllerReconstructRate OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The reconstruct rate is the percentage of the controller's resources
|
|
dedicated to reconstructing a disk group after adding a physical disk
|
|
or changing the RAID level of a virtual disk residing on the disk
|
|
group.
|
|
"
|
|
::= { controllerTableEntry 48 }
|
|
|
|
controllerPatrolReadRate OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The patrol read rate is the percentage of the controller's
|
|
resources dedicated to perform a patrol read on disks participating
|
|
in a virtual disk or hot spares.
|
|
"
|
|
::= { controllerTableEntry 49 }
|
|
|
|
controllerBGIRate OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The background initialization (BGI) rate is the percentage of the
|
|
controller's resources dedicated to performing the background
|
|
initialization of a redundant virtual disk after it is created.
|
|
"
|
|
::= { controllerTableEntry 50 }
|
|
|
|
controllerCheckConsistencyRate OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The check consistency rate is the percentage of the
|
|
controller's resources dedicated to performing a check consistency
|
|
on a redundant virtual disk.
|
|
"
|
|
::= { controllerTableEntry 51 }
|
|
|
|
controllerPatrolReadMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notSupported(2),
|
|
disabled(3),
|
|
auto(4),
|
|
manual(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identifies the patrol read mode setting for the controller.
|
|
Possible values:
|
|
1: Not one of the following or could not be determined.
|
|
2: Not Supported on this controller.
|
|
3: Disabled.
|
|
4: Automatic.
|
|
5: Manual.
|
|
"
|
|
::= { controllerTableEntry 52 }
|
|
|
|
controllerPatrolReadState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
stopped(2),
|
|
active(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This property displays the current state of the patrol read process.
|
|
Possible values:
|
|
1: Not one of the following or could not be determined.
|
|
2: Patrol read is not running.
|
|
3: Patrol read is running.
|
|
"
|
|
::= { controllerTableEntry 53 }
|
|
|
|
controllerPersistentHotSpare OBJECT-TYPE
|
|
SYNTAX BooleanType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether hot spare drives would be restored on insertion
|
|
into the same slot.
|
|
"
|
|
::= { controllerTableEntry 59 }
|
|
|
|
controllerSpinDownUnconfiguredDrives OBJECT-TYPE
|
|
SYNTAX BooleanType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether un-configured drives would be put in power
|
|
save mode by the controller.
|
|
"
|
|
::= { controllerTableEntry 60 }
|
|
|
|
controllerSpinDownHotSpareDrives OBJECT-TYPE
|
|
SYNTAX BooleanType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether hot spare drives would be put in power
|
|
save mode by the controller.
|
|
"
|
|
::= { controllerTableEntry 61 }
|
|
|
|
controllerSpinDownTimeInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (30..1440)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The duration in minutes after which, the unconfigured or hot
|
|
spare drives will be spun down to power save mode.
|
|
"
|
|
::= { controllerTableEntry 62 }
|
|
|
|
controllerPreservedCache OBJECT-TYPE
|
|
SYNTAX BooleanType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether preserved cache or pinned cache is
|
|
present on the controller.
|
|
"
|
|
::= { controllerTableEntry 69 }
|
|
|
|
controllerCheckConsistencyMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
unsupported(2),
|
|
normal(3),
|
|
stopOnError(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current check consistency mode setting
|
|
for the controller.
|
|
Possible values:
|
|
1: Not one of the following.
|
|
2: Not supported on this controller.
|
|
3: Normal check consistency operation.
|
|
4: Check consistency operation will stop on encountering
|
|
an error.
|
|
"
|
|
::= { controllerTableEntry 70 }
|
|
|
|
controllerCopyBackMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
unsupported(2),
|
|
on(3),
|
|
onWithSmart(4),
|
|
off(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current copy back mode setting
|
|
for the controller.
|
|
Possible values:
|
|
1: Not one of the following.
|
|
2: Not supported on this controller.
|
|
3: Disks assigned as spares could revert back to spare status.
|
|
4: Data from physical disk participating in a
|
|
virtual disk could be automatically copied to the assigned
|
|
hot spare in case former has a predictive failure event.
|
|
5: Copyback mode is disabled.
|
|
"
|
|
::= { controllerTableEntry 71 }
|
|
|
|
controllerSecurityStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
none(2),
|
|
lkm(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The controller's current security/encryption status..
|
|
Possible values:
|
|
1: The current status could not be determined.
|
|
2: Controller is not operating in an encryption mode.
|
|
3: Controller is operating in the Local Key Management
|
|
(LKM) encryption mode.
|
|
"
|
|
::= { controllerTableEntry 72 }
|
|
|
|
controllerEncryptionKeyPresent OBJECT-TYPE
|
|
SYNTAX BooleanType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether encryption key is assigned for the controller.
|
|
"
|
|
::= { controllerTableEntry 73 }
|
|
|
|
controllerEncryptionCapability OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
none(2),
|
|
lkm(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of encryption supported by the controller.
|
|
Possible values:
|
|
1: Not one of the following.
|
|
2: No encryption supported,
|
|
3: Local Key Management,
|
|
"
|
|
::= { controllerTableEntry 74 }
|
|
|
|
controllerLoadBalanceSetting OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
unsupported(2),
|
|
auto(3),
|
|
none(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ability of the controller to automatically use both
|
|
controller ports (or connectors) connected to the same enclosure in
|
|
order to route I/O requests.
|
|
Possible values:
|
|
1: Not one of the following.
|
|
2: Not supported.
|
|
3: Automatic load balancing is active.
|
|
4: Load balancing is inactive.
|
|
"
|
|
::= { controllerTableEntry 75 }
|
|
|
|
controllerMaxCapSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
oneDotFiveGbps(2),
|
|
threeGbps(3),
|
|
sixGbps(4),
|
|
twelveGbps(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum speed of the controller.in
|
|
Gigbits per second (Gbps).
|
|
Possible values:
|
|
1: The speed could not be determined.
|
|
2. 1.5 Gbps
|
|
3: 3.0 Gbps
|
|
4: 6.0 Gbps
|
|
5: 12.0 Gbps
|
|
"
|
|
::= { controllerTableEntry 76 }
|
|
|
|
controllerSASAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The SAS address of the controller.
|
|
"
|
|
::= { controllerTableEntry 77 }
|
|
|
|
controllerFQDD OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The controller's Fully Qualified Device Descriptor (FQDD) as
|
|
represented in Storage Management.
|
|
"
|
|
::= { controllerTableEntry 78 }
|
|
|
|
controllerDisplayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The controller's friendly FQDD as represented in Storage
|
|
Management."
|
|
::= { controllerTableEntry 79 }
|
|
|
|
controllerT10PICapability OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
capable(2),
|
|
notCapable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the controller supports the T10 PI (Protection
|
|
Information). These protection fields are known as DIF
|
|
(Data Integrity Fields).
|
|
Possible values:
|
|
1: Not one of the following.
|
|
2: Capable of supporting T10 PI.
|
|
3: Not capable of supporting T10 PI.
|
|
"
|
|
::= { controllerTableEntry 80 }
|
|
|
|
controllerRAID10UnevenSpansSupported OBJECT-TYPE
|
|
SYNTAX BooleanType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether uneven spans for RAID 10 virtual disk
|
|
is supported on the controller.
|
|
"
|
|
::= { controllerTableEntry 81 }
|
|
|
|
controllerEnhancedAutoImportForeignConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notSupported(2),
|
|
disabled(3),
|
|
enabled(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the status of enhanced auto-import of foreign
|
|
configuration property of the controller.
|
|
1: Not one of the following.
|
|
2: Not Supported.
|
|
3: Disabled.
|
|
4: Enabled.
|
|
"
|
|
::= { controllerTableEntry 82 }
|
|
|
|
controllerBootModeSupported OBJECT-TYPE
|
|
SYNTAX BooleanType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether headless boot mode settings are supported
|
|
on the controller.
|
|
"
|
|
::= { controllerTableEntry 83 }
|
|
|
|
controllerBootMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
user(2),
|
|
contOnError(3),
|
|
headlessContOnError(4),
|
|
headlessSafe(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the boot mode of the controller.
|
|
Possible values:
|
|
1: Not applicable for this controller.
|
|
2: User mode: User interaction required for all boot messages (not
|
|
applicable for uEFI environments).
|
|
3: Continue Boot On Error. User interaction only required for
|
|
critical messages.
|
|
4: Headless Mode Continue On Error. User interaction is not required.
|
|
Controller boot may halt on Error.
|
|
5: Headless Safe Mode. Controller shall boot to safe mode on critical
|
|
errors.
|
|
"
|
|
::= { controllerTableEntry 84 }
|
|
|
|
controllerHighAvailabilityMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
faultTolerantActivePassive (2),
|
|
faultTolerantActiveActive (3),
|
|
degraded (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the fault-tolerant mode of the controller.
|
|
Possible values:
|
|
1: None
|
|
2: Fault Tolerant(Active/Passive)
|
|
3: Fault Tolerant(Active/Active)
|
|
4: Degraded
|
|
"
|
|
::= { controllerTableEntry 85 }
|
|
|
|
controllerPeerController OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peer controller's Fully Qualified Device Descriptor (FQDD) as
|
|
represented in Storage Management.
|
|
"
|
|
::= { controllerTableEntry 86 }
|
|
|
|
controllerEncryptionKeyIdentifier OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Displays the encryption security key identifier of the controller, if the
|
|
controller is encryption enabled and a security key is configured for the
|
|
controller."
|
|
::= { controllerTableEntry 87 }
|
|
|
|
|
|
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Physical Disk Table
|
|
--
|
|
-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.<a>.<i1>
|
|
-------------------------------------------------------------------------------
|
|
|
|
PhysicalDiskTableEntry ::=SEQUENCE {
|
|
physicalDiskNumber INTEGER,
|
|
physicalDiskName DisplayString,
|
|
physicalDiskManufacturer DisplayString,
|
|
physicalDiskState INTEGER,
|
|
physicalDiskProductID DisplayString,
|
|
physicalDiskSerialNo DisplayString,
|
|
physicalDiskRevision DisplayString,
|
|
physicalDiskCapacityInMB INTEGER,
|
|
physicalDiskUsedSpaceInMB INTEGER,
|
|
physicalDiskFreeSpaceInMB INTEGER,
|
|
physicalDiskBusType INTEGER,
|
|
physicalDiskSpareState INTEGER,
|
|
physicalDiskComponentStatus ObjectStatusEnum,
|
|
physicalDiskPartNumber DisplayString,
|
|
physicalDiskSASAddress DisplayString,
|
|
physicalDiskNegotiatedSpeed INTEGER,
|
|
physicalDiskCapableSpeed INTEGER,
|
|
physicalDiskSmartAlertIndication BooleanType,
|
|
physicalDiskManufactureDay DisplayString,
|
|
physicalDiskManufactureWeek DisplayString,
|
|
physicalDiskManufactureYear DisplayString,
|
|
physicalDiskMediaType INTEGER,
|
|
physicalDiskPowerState INTEGER,
|
|
physicalDiskRemainingRatedWriteEndurance INTEGER,
|
|
physicalDiskOperationalState INTEGER,
|
|
physicalDiskProgress INTEGER,
|
|
physicalDiskSecurityStatus INTEGER,
|
|
physicalDiskFormFactor INTEGER,
|
|
physicalDiskFQDD FQDDString,
|
|
physicalDiskDisplayName DisplayString,
|
|
physicalDiskT10PICapability INTEGER,
|
|
physicalDiskBlockSizeInBytes INTEGER,
|
|
physicalDiskProtocolVersion DisplayString,
|
|
physicalDiskPCIeNegotiatedLinkWidth INTEGER,
|
|
physicalDiskPCIeCapableLinkWidth INTEGER,
|
|
physicalDiskCurrentActiveController FQDDString,
|
|
physicalDiskFailoverController FQDDString,
|
|
physicalDiskForeignKeyIdentifier DisplayString
|
|
}
|
|
|
|
physicalDiskTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PhysicalDiskTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of managed physical disks. The number of entries is
|
|
related to number of physical Disks discovered in the system.
|
|
The maximum number of entries is implementation dependent.
|
|
Note: The properties in this table may not be applicable to
|
|
all entries.
|
|
"
|
|
::= { physicalDevices 4 }
|
|
|
|
physicalDiskTableEntry OBJECT-TYPE
|
|
SYNTAX PhysicalDiskTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the physical Disk table. A row in this table cannot be
|
|
created or deleted by SNMP operations on columns of the table.
|
|
"
|
|
INDEX { physicalDiskNumber }
|
|
::= { physicalDiskTable 1 }
|
|
|
|
physicalDiskNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1000000000)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Instance number of this physical disk entry.
|
|
"
|
|
::= { physicalDiskTableEntry 1 }
|
|
|
|
physicalDiskName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical disk's name as represented in Storage Management.
|
|
"
|
|
::= { physicalDiskTableEntry 2 }
|
|
|
|
physicalDiskManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the physical disk's manufacturer.
|
|
"
|
|
::= { physicalDiskTableEntry 3 }
|
|
|
|
physicalDiskState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
ready(2),
|
|
online(3),
|
|
foreign(4),
|
|
offline(5),
|
|
blocked(6),
|
|
failed(7),
|
|
nonraid(8),
|
|
removed(9),
|
|
readonly(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of this physical disk.
|
|
Possible states:
|
|
1: The current state could not be determined.
|
|
2: The physical disk is available for use, but no RAID configuration
|
|
has been assigned.
|
|
3: A RAID configuration has been assigned to the physical disk.
|
|
4: The physical disk has been moved from another
|
|
controller and contains all or some portion of a virtual disk.
|
|
5: The physical disk is not available to the RAID
|
|
controller.
|
|
6: The physical disk is currently blocked by
|
|
controller.
|
|
7: The physical disk is not operational.
|
|
8: The physical disk is not a RAID capable disk
|
|
9: The physical disk has been removed.
|
|
10:The physical disk media has been placed in read only mode.
|
|
"
|
|
::= { physicalDiskTableEntry 4 }
|
|
|
|
physicalDiskProductID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The model number of the physical disk.
|
|
"
|
|
::= { physicalDiskTableEntry 6 }
|
|
|
|
physicalDiskSerialNo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical disk's unique identification number
|
|
from the manufacturer.
|
|
"
|
|
::= { physicalDiskTableEntry 7 }
|
|
|
|
physicalDiskRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware version of the physical disk.
|
|
"
|
|
::= { physicalDiskTableEntry 8 }
|
|
|
|
physicalDiskCapacityInMB OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the physical disk in megabytes.
|
|
"
|
|
::= { physicalDiskTableEntry 11 }
|
|
|
|
physicalDiskUsedSpaceInMB OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of used space in megabytes on the physical
|
|
disk. This is not applicable for NVMe devices.
|
|
"
|
|
::= { physicalDiskTableEntry 17 }
|
|
|
|
physicalDiskFreeSpaceInMB OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of free space in megabytes on the physical
|
|
disk. This is not applicable for NVMe devices.
|
|
"
|
|
::= { physicalDiskTableEntry 19 }
|
|
|
|
physicalDiskBusType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
scsi(2),
|
|
sas(3),
|
|
sata(4),
|
|
fibre(5),
|
|
pcie(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bus type of the physical disk.
|
|
Possible values:
|
|
1: The bus type could not be determined.
|
|
2: Small Computer System Interface (SCSI).
|
|
3: Serial Attached SCSI (SAS).
|
|
4: Serial Advanced Technology Attachment (SATA).
|
|
5: Fibre channel.
|
|
6: PCIe.
|
|
"
|
|
::= { physicalDiskTableEntry 21 }
|
|
|
|
physicalDiskSpareState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notASpare(1),
|
|
dedicatedHotSpare(2),
|
|
globalHotSpare(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the disk as a spare.
|
|
Possible values:
|
|
1: Physical disk is not a spare.
|
|
2: Physical disk is a dedicated hot spare.
|
|
3: Physical disk is a global hot spare.
|
|
"
|
|
::= { physicalDiskTableEntry 22 }
|
|
|
|
physicalDiskComponentStatus OBJECT-TYPE
|
|
SYNTAX ObjectStatusEnum
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the physical disk itself without the
|
|
propagation of any contained component status.
|
|
Possible values:
|
|
1: Other
|
|
2: Unknown
|
|
3: OK
|
|
4: Non-critical
|
|
5: Critical
|
|
6: Non-recoverable
|
|
"
|
|
::= { physicalDiskTableEntry 24 }
|
|
|
|
physicalDiskPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The part number of the disk.
|
|
"
|
|
::= { physicalDiskTableEntry 27 }
|
|
|
|
physicalDiskSASAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The SAS address of the physical disk.
|
|
"
|
|
::= { physicalDiskTableEntry 28 }
|
|
|
|
physicalDiskNegotiatedSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
oneDotFiveGbps(2),
|
|
threeGbps(3),
|
|
sixGbps(4),
|
|
twelveGbps(5),
|
|
fiveGTps(6),
|
|
eightGTps(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The data transfer speed that the disk negotiated while spinning up
|
|
in Gigbits per second (Gbps).
|
|
Possible values:
|
|
1: The speed could not be determined.
|
|
2. 1.5 Gbps
|
|
3: 3.0 Gbps
|
|
4: 6.0 Gbps
|
|
5: 12.0 Gbps
|
|
6: 5 GT/s (applicable for NVMe devices).
|
|
7: 8 GT/s (applicable for NVMe devices).
|
|
"
|
|
::= { physicalDiskTableEntry 29 }
|
|
|
|
physicalDiskCapableSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
oneDotFiveGbps(2),
|
|
threeGbps(3),
|
|
sixGbps(4),
|
|
twelveGbps(5),
|
|
fiveGTps(6),
|
|
eightGTps(7)
|
|
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum data transfer speed supported by the disk
|
|
in Gigbits per second (Gbps).
|
|
Possible values:
|
|
1: The speed could not be determined.
|
|
2. 1.5 Gbps
|
|
3: 3.0 Gbps
|
|
4: 6.0 Gbps
|
|
5: 12.0 Gbps
|
|
6: 5 GT/s (applicable for NVMe devices).
|
|
7: 8 GT/s (applicable for NVMe devices).
|
|
"
|
|
::= { physicalDiskTableEntry 30 }
|
|
|
|
physicalDiskSmartAlertIndication OBJECT-TYPE
|
|
SYNTAX BooleanType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the physical disk has received a predictive
|
|
failure alert.
|
|
"
|
|
::= { physicalDiskTableEntry 31 }
|
|
|
|
physicalDiskManufactureDay OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The day of the week (1=Sunday thru 7=Saturday)
|
|
on which the physical disk was manufactured.
|
|
"
|
|
::= { physicalDiskTableEntry 32 }
|
|
|
|
physicalDiskManufactureWeek OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The week (1 thru 53) in which the physical disk
|
|
was manufactured.
|
|
"
|
|
::= { physicalDiskTableEntry 33 }
|
|
|
|
physicalDiskManufactureYear OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The four digit year in which the physical disk was manufactured.
|
|
"
|
|
::= { physicalDiskTableEntry 34 }
|
|
|
|
physicalDiskMediaType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
hdd(2),
|
|
ssd(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The media type of the physical disk.
|
|
Possible Values:
|
|
1: The media type could not be determined.
|
|
2: Hard Disk Drive (HDD).
|
|
3: Solid State Device (SSD).
|
|
"
|
|
::= { physicalDiskTableEntry 35 }
|
|
|
|
physicalDiskPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
spunUp(2),
|
|
spunDown(3),
|
|
transition(4),
|
|
on(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power state of the physical disk.
|
|
Possible Values:
|
|
1: Not one of the following.
|
|
2: The physical disk is in the spun up state.
|
|
3: The physical disk is in the spun down state.
|
|
4: The physical disk is changing from spun down state
|
|
to spun up state or vice versa.
|
|
5: The Solid State Device (SSD) is powered on.
|
|
"
|
|
::= { physicalDiskTableEntry 42 }
|
|
|
|
physicalDiskRemainingRatedWriteEndurance OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This property is applicable to SSD media type only. This indicates
|
|
the wear-out percentage of the SSD. Typically it is a value between
|
|
0 to 100. However, if the value is not available or not applicable
|
|
(in the case of HDD media type) the value will be 255.
|
|
"
|
|
::= { physicalDiskTableEntry 49 }
|
|
|
|
physicalDiskOperationalState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
rebuild(2),
|
|
clear(3),
|
|
copyback(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the physical disk when there are progressive
|
|
operations ongoing.
|
|
Possible values:
|
|
1: There is no active operation running.
|
|
2: Data from a redundant virtual disk is
|
|
currently being rebuilt onto the physical disk.
|
|
3: Data on the disk is being erased.
|
|
4: Data is being copied from a hot spare disk to
|
|
the physical disk or vice versa.
|
|
"
|
|
::= { physicalDiskTableEntry 50 }
|
|
|
|
physicalDiskProgress OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The progress percentage of the operation that is being
|
|
performed on the physical disk. This is applicable
|
|
only if there is a progressive operations ongoing
|
|
"
|
|
::= { physicalDiskTableEntry 51 }
|
|
|
|
physicalDiskSecurityStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
supported(1),
|
|
notSupported(2),
|
|
secured(3),
|
|
locked(4),
|
|
foreign(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The security/encryption status of the physical disk.
|
|
Possible Values:
|
|
1: The physical disk supports encryption.
|
|
2: The physical disk does not support encryption
|
|
3: The physical disk is encrypted.
|
|
4: The physical disk is locked by a key.
|
|
5: The physical disk is locked by a foreign key.
|
|
"
|
|
::= { physicalDiskTableEntry 52 }
|
|
|
|
physicalDiskFormFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
oneDotEight(2),
|
|
twoDotFive(3),
|
|
threeDotFive(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The form factor of the physical disk.
|
|
Possible values:
|
|
1: The form factor could not be determined.
|
|
2: 1.8 inch.
|
|
3: 2.5 inch.
|
|
4: 3.5 inch.
|
|
"
|
|
::= { physicalDiskTableEntry 53 }
|
|
|
|
physicalDiskFQDD OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical disk's Fully Qualified Device Descriptor (FQDD)
|
|
as represented in Storage Management.
|
|
"
|
|
::= { physicalDiskTableEntry 54 }
|
|
|
|
physicalDiskDisplayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical disk's friendly FQDD as represented in Storage
|
|
Management.
|
|
"
|
|
::= { physicalDiskTableEntry 55 }
|
|
|
|
physicalDiskT10PICapability OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
capable(2),
|
|
notCapable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the physical disk supports the T10 PI (Protection
|
|
Information). These protection fields are known as DIF
|
|
(Data Integrity Fields).
|
|
Possible values:
|
|
1: Not one of the following.
|
|
2: Capable of supporting T10 PI.
|
|
3: Not capable of supporting T10 PI.
|
|
"
|
|
::= { physicalDiskTableEntry 57 }
|
|
|
|
physicalDiskBlockSizeInBytes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The block size (in bytes) of the physical disk. This is not
|
|
applicable for NVMe devices.
|
|
Possible values:
|
|
1: 512.
|
|
2: 4096
|
|
"
|
|
::= { physicalDiskTableEntry 58 }
|
|
|
|
physicalDiskProtocolVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Applicable for NVMe devices only. The NVMe protocol version supported
|
|
by the device.
|
|
"
|
|
::= { physicalDiskTableEntry 59 }
|
|
|
|
physicalDiskPCIeNegotiatedLinkWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notApplicable(2),
|
|
byOne(3),
|
|
byTwp(4),
|
|
byFour(5),
|
|
byEight(6),
|
|
bySixteen(7),
|
|
byThirtyTwp(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Applicable for NVMe devices only. The PCIe link width negotiated with the host
|
|
during device initialization.
|
|
"
|
|
::= { physicalDiskTableEntry 60 }
|
|
|
|
physicalDiskPCIeCapableLinkWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notApplicable(2),
|
|
byOne(3),
|
|
byTwp(4),
|
|
byFour(5),
|
|
byEight(6),
|
|
bySixteen(7),
|
|
byThirtyTwp(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Applicable for NVMe devices only. The PCIe link widths the device is capable of
|
|
supporting.
|
|
"
|
|
::= { physicalDiskTableEntry 61 }
|
|
|
|
physicalDiskCurrentActiveController OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Fully Qualified Device Descriptor (FQDD) of
|
|
the current active controller.
|
|
"
|
|
::= { physicalDiskTableEntry 62 }
|
|
|
|
physicalDiskFailoverController OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Fully Qualified Device Descriptor (FQDD) of
|
|
the failover controller.
|
|
"
|
|
::= { physicalDiskTableEntry 63 }
|
|
|
|
physicalDiskForeignKeyIdentifier OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Displays the encryption key identifier of the physical disk if it is in
|
|
locked or foreign state."
|
|
|
|
::= { physicalDiskTableEntry 64 }
|
|
|
|
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Virtual Disk Table
|
|
--
|
|
-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.<a>.<i1>
|
|
-------------------------------------------------------------------------------
|
|
VirtualDiskTableEntry ::=SEQUENCE {
|
|
virtualDiskNumber INTEGER,
|
|
virtualDiskName DisplayString,
|
|
virtualDiskState INTEGER,
|
|
virtualDiskSizeInMB INTEGER,
|
|
virtualDiskWritePolicy INTEGER,
|
|
virtualDiskReadPolicy INTEGER,
|
|
virtualDiskLayout INTEGER,
|
|
virtualDiskStripeSize INTEGER,
|
|
virtualDiskComponentStatus ObjectStatusEnum,
|
|
virtualDiskBadBlocksDetected BooleanType,
|
|
virtualDiskSecured BooleanType,
|
|
virtualDiskIsCacheCade BooleanType,
|
|
virtualDiskDiskCachePolicy INTEGER,
|
|
virtualDiskOperationalState INTEGER,
|
|
virtualDiskProgress INTEGER,
|
|
virtualDiskAvailableProtocols DisplayString,
|
|
virtualDiskMediaType DisplayString,
|
|
virtualDiskRemainingRedundancy INTEGER,
|
|
virtualDiskFQDD FQDDString,
|
|
virtualDiskDisplayName DisplayString,
|
|
virtualDiskT10PIStatus INTEGER,
|
|
virtualDiskBlockSizeInBytes INTEGER,
|
|
virtualDiskAdapter1AccessPolicy INTEGER,
|
|
virtualDiskAdapter2AccessPolicy INTEGER,
|
|
virtualDiskAdapter3AccessPolicy INTEGER,
|
|
virtualDiskAdapter4AccessPolicy INTEGER,
|
|
virtualDiskCurrentActiveController FQDDString,
|
|
virtualDiskFailoverController FQDDString
|
|
}
|
|
|
|
virtualDiskTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VirtualDiskTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of managed virtual disks. The number of entries is related
|
|
to number of virtual disks discovered in the system.
|
|
The maximum number of entries is implementation dependent.
|
|
Note: The properties in this table may not be applicable to all
|
|
entries.
|
|
"
|
|
::= { logicalDevices 1 }
|
|
|
|
virtualDiskTableEntry OBJECT-TYPE
|
|
SYNTAX VirtualDiskTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the virtual disk table. A row in this table cannot be
|
|
created or deleted by SNMP operations on columns of the table.
|
|
"
|
|
INDEX { virtualDiskNumber }
|
|
::= { virtualDiskTable 1 }
|
|
|
|
virtualDiskNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100000000)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Instance number of this virtual disk entry.
|
|
"
|
|
::= { virtualDiskTableEntry 1 }
|
|
|
|
virtualDiskName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The virtual disk's label as entered by the user.
|
|
"
|
|
::= { virtualDiskTableEntry 2 }
|
|
|
|
virtualDiskState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
online(2),
|
|
failed(3),
|
|
degraded(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of this virtual disk
|
|
(which includes any member physical disks.)
|
|
Possible states:
|
|
1: The current state could not be determined.
|
|
2: The virtual disk is operating normally or optimally.
|
|
3: The virtual disk has encountered a failure. The data on disk
|
|
is lost or is about to be lost.
|
|
4: The virtual disk encounterd a failure with one or all of the
|
|
constituent redundant physical disks. The data on the virtual
|
|
disk might no longer be fault tolerant.
|
|
"
|
|
::= { virtualDiskTableEntry 4 }
|
|
|
|
virtualDiskSizeInMB OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the virtual disk in megabytes.
|
|
"
|
|
::= { virtualDiskTableEntry 6 }
|
|
|
|
virtualDiskWritePolicy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
writeThrough(1),
|
|
writeBack(2),
|
|
writeBackForce(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The write policy used by the controller for write operations on
|
|
this virtual disk.
|
|
Possible values:
|
|
1: Write Through.
|
|
2: Write Back.
|
|
3: Force Write Back.
|
|
"
|
|
::= { virtualDiskTableEntry 10 }
|
|
|
|
virtualDiskReadPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noReadAhead(1),
|
|
readAhead(2),
|
|
adaptiveReadAhead(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The read policy used by the controller for read operations on
|
|
this virtual disk.
|
|
Possible values:
|
|
1: No Read Ahead.
|
|
2: Read Ahead.
|
|
3: Adaptive Read Ahead.
|
|
"
|
|
::= { virtualDiskTableEntry 11 }
|
|
|
|
virtualDiskLayout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
r0(2),
|
|
r1(3),
|
|
r5(4),
|
|
r6(5),
|
|
r10(6),
|
|
r50(7),
|
|
r60(8),
|
|
concatRaid1(9),
|
|
concatRaid5(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The virtual disk's RAID type.
|
|
Possible values:
|
|
1: Not one of the following
|
|
2: RAID-0
|
|
3: RAID-1
|
|
4: RAID-5
|
|
5: RAID-6
|
|
6: RAID-10
|
|
7: RAID-50
|
|
8: RAID-60
|
|
9: Concatenated RAID 1
|
|
10: Concatenated RAID 5
|
|
"
|
|
::= { virtualDiskTableEntry 13 }
|
|
|
|
virtualDiskStripeSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
default(2),
|
|
fiveHundredAndTwelvebytes(3),
|
|
oneKilobytes(4),
|
|
twoKilobytes(5),
|
|
fourKilobytes(6),
|
|
eightKilobytes(7),
|
|
sixteenKilobytes(8),
|
|
thirtyTwoKilobytes(9),
|
|
sixtyFourKilobytes(10),
|
|
oneTwentyEightKilobytes(11),
|
|
twoFiftySixKilobytes(12),
|
|
fiveOneTwoKilobytes(13),
|
|
oneMegabye(14),
|
|
twoMegabytes(15),
|
|
fourMegabytes(16),
|
|
eightMegabytes(17),
|
|
sixteenMegabytes(18)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The stripe size of this virtual disk.
|
|
Possible values:
|
|
1: Not one of the following
|
|
2: Default.
|
|
3: 512 bytes
|
|
4: 1 kB,
|
|
5: 2 kB,
|
|
6: 4 kB,
|
|
7: 8 kB,
|
|
8: 16 kB,
|
|
9: 32 kB,
|
|
10: 64 kB,
|
|
11: 128 kB,
|
|
12: 256 kB,
|
|
13: 512 kB,
|
|
14: 1 MB,
|
|
15: 2 MB,
|
|
16: 4 MB,
|
|
17: 8 MB,
|
|
18: 16 MB
|
|
"
|
|
::= { virtualDiskTableEntry 14 }
|
|
|
|
virtualDiskComponentStatus OBJECT-TYPE
|
|
SYNTAX ObjectStatusEnum
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the virtual disk itself without the
|
|
propagation of any contained component status.
|
|
Possible values:
|
|
1: Other.
|
|
2: Unknown.
|
|
3: OK.
|
|
4: Non-critical .
|
|
5: Critical.
|
|
6: Non-recoverable.
|
|
"
|
|
::= { virtualDiskTableEntry 20 }
|
|
|
|
virtualDiskBadBlocksDetected OBJECT-TYPE
|
|
SYNTAX BooleanType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the virtual disk has bad blocks.
|
|
"
|
|
::= { virtualDiskTableEntry 23 }
|
|
|
|
virtualDiskSecured OBJECT-TYPE
|
|
SYNTAX BooleanType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the virtual disk is secured or not.
|
|
"
|
|
::= { virtualDiskTableEntry 24 }
|
|
|
|
virtualDiskIsCacheCade OBJECT-TYPE
|
|
SYNTAX BooleanType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the virtual disk is being used as a secondary
|
|
cache by the controller.
|
|
"
|
|
::= { virtualDiskTableEntry 25 }
|
|
|
|
virtualDiskDiskCachePolicy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2),
|
|
defullt(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cache policy of the physical disks that are
|
|
part of this virtual disk
|
|
Possible values:
|
|
1: Enabled.
|
|
2: Disabled.
|
|
3: Default.
|
|
"
|
|
::= { virtualDiskTableEntry 26 }
|
|
|
|
virtualDiskOperationalState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
reconstructing(2),
|
|
resynching(3),
|
|
initializing(4),
|
|
backgroundInit(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the virtual disk when there are progressive
|
|
operations ongoing.
|
|
Possible values:
|
|
1: There is no active operation running.
|
|
2: The virtual disk configuration has changed.
|
|
The physical disks included in the virtual disk are being
|
|
modified to support the new configuration.
|
|
3: A Consistency Check (CC) is being performed
|
|
on the virtual disk.
|
|
4: The virtual disk is being initialized.
|
|
5: BackGround Initialization (BGI) is being performed
|
|
on the virtual disk.
|
|
"
|
|
::= { virtualDiskTableEntry 30 }
|
|
|
|
virtualDiskProgress OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The progress percentage of the operation that is being
|
|
performed on the virtual disk. This is applicable
|
|
only if there is a progressive operations ongoing
|
|
"
|
|
::= { virtualDiskTableEntry 31 }
|
|
|
|
virtualDiskAvailableProtocols OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of protocols support by physical disks part of this virtual
|
|
disk. For e.g. SAS for Serial Attached SCSI or SATA for
|
|
Serial Advanced Technology Attachment.
|
|
"
|
|
::= { virtualDiskTableEntry 32 }
|
|
|
|
virtualDiskMediaType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of media types of the physical disks part of this virtual
|
|
disk. For e.g. HDD for Hard Disk Drive or SSD for Solid State Device.
|
|
"
|
|
::= { virtualDiskTableEntry 33 }
|
|
|
|
virtualDiskRemainingRedundancy OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of physical disks which can be lost before the
|
|
virtual disk loses its redundancy.
|
|
"
|
|
::= { virtualDiskTableEntry 34 }
|
|
|
|
virtualDiskFQDD OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The virtual disk's Fully Qualified Device Descriptor (FQDD) as
|
|
represented in Storage Management.
|
|
"
|
|
::= { virtualDiskTableEntry 35 }
|
|
|
|
virtualDiskDisplayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The virtual disk's friendly FQDD as represented in Storage
|
|
Management.
|
|
"
|
|
::= { virtualDiskTableEntry 36 }
|
|
|
|
virtualDiskT10PIStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the virtual disk supports the T10 PI (Protection
|
|
Information). These protection fields are known as DIF
|
|
(Data Integrity Fields).
|
|
Possible values:
|
|
1: Not one of the following.
|
|
2: Enabled.
|
|
3: Disabled.
|
|
"
|
|
::= { virtualDiskTableEntry 37 }
|
|
|
|
virtualDiskBlockSizeInBytes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The block size (in bytes) of the physical disk part of the virtual disk.
|
|
Possible values:
|
|
1: 512.
|
|
2: 4096
|
|
"
|
|
::= { virtualDiskTableEntry 38 }
|
|
|
|
virtualDiskAdapter1AccessPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noAccess (1),
|
|
fullAccess (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the access policy of the virtual disk with the virtual
|
|
adapters.
|
|
Possible values:
|
|
1: No Access.
|
|
2: Full Access
|
|
"
|
|
::= { virtualDiskTableEntry 39 }
|
|
|
|
virtualDiskAdapter2AccessPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noAccess (1),
|
|
fullAccess (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the access policy of the virtual disk with the virtual
|
|
adapters.
|
|
Possible values:
|
|
1: No Access.
|
|
2: Full Access
|
|
"
|
|
::= { virtualDiskTableEntry 40 }
|
|
|
|
virtualDiskAdapter3AccessPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noAccess (1),
|
|
fullAccess (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the access policy of the virtual disk with the virtual
|
|
adapters.
|
|
Possible values:
|
|
1: No Access.
|
|
2: Full Access
|
|
"
|
|
::= { virtualDiskTableEntry 41 }
|
|
|
|
virtualDiskAdapter4AccessPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noAccess (1),
|
|
fullAccess (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the access policy of the virtual disk with the virtual
|
|
adapters.
|
|
Possible values:
|
|
1: No Access.
|
|
2: Full Access
|
|
"
|
|
::= { virtualDiskTableEntry 42 }
|
|
|
|
virtualDiskCurrentActiveController OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Fully Qualified Device Descriptor (FQDD) of
|
|
the current active controller.
|
|
"
|
|
::= { virtualDiskTableEntry 43 }
|
|
|
|
virtualDiskFailoverController OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Fully Qualified Device Descriptor (FQDD) of
|
|
the failover controller.
|
|
"
|
|
::= { virtualDiskTableEntry 44 }
|
|
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Enclosure Table
|
|
--
|
|
-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.<a>.<i1>
|
|
-------------------------------------------------------------------------------
|
|
|
|
EnclosureTableEntry ::=SEQUENCE {
|
|
enclosureNumber INTEGER,
|
|
enclosureName DisplayString,
|
|
enclosureState INTEGER,
|
|
enclosureServiceTag DisplayString,
|
|
enclosureAssetTag DisplayString,
|
|
enclosureConnectedPort DisplayString,
|
|
enclosureRollUpStatus ObjectStatusEnum,
|
|
enclosureComponentStatus ObjectStatusEnum,
|
|
enclosureFirmwareVersion DisplayString,
|
|
enclosureSASAddress DisplayString,
|
|
enclosureDriveCount INTEGER,
|
|
enclosureTotalSlots INTEGER,
|
|
enclosureFanCount DisplayString,
|
|
enclosurePSUCount DisplayString,
|
|
enclosureEMMCount DisplayString,
|
|
enclosureTempProbeCount DisplayString,
|
|
enclosureRedundantPath DisplayString,
|
|
enclosurePosition DisplayString,
|
|
enclosureBackplaneBayID DisplayString,
|
|
enclosureFQDD FQDDString,
|
|
enclosureDisplayName DisplayString,
|
|
enclosureType INTEGER
|
|
}
|
|
|
|
enclosureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EnclosureTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of managed enclosures/backplanes. The number of entries is
|
|
related to number of internal backplane(s) discovered in the system
|
|
and external storage enclosure(s) attached to the system..
|
|
The maximum number of entries is implementation dependent.
|
|
Note: The properties in this table may not be applicable to all
|
|
entries.
|
|
"
|
|
::= { physicalDevices 3 }
|
|
|
|
enclosureTableEntry OBJECT-TYPE
|
|
SYNTAX EnclosureTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the enclosure table. A row in this table cannot be
|
|
created or deleted by SNMP operations on columns of the table.
|
|
"
|
|
INDEX { enclosureNumber }
|
|
::= { enclosureTable 1 }
|
|
|
|
enclosureNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Instance number of this enclossre/backplane.
|
|
"
|
|
::= { enclosureTableEntry 1 }
|
|
|
|
enclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure/backplane's name as represented in Storage Management.
|
|
"
|
|
::= { enclosureTableEntry 2 }
|
|
|
|
enclosureState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
ready(2),
|
|
failed(3),
|
|
missing(4),
|
|
degraded(5),
|
|
foreign(6),
|
|
offline(7),
|
|
online(8),
|
|
blocked(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of this enclosure/backplane.
|
|
Possible states:
|
|
1: The current state could not be determined.
|
|
2: The enclosure is operating normally.
|
|
3: The enclosure has encountered a hardware problem or is not
|
|
responding.
|
|
4: The enclosure is no longer connected to the controller or
|
|
there exists a problem communicating to the enclosure.
|
|
5: The enclosure is unstable.
|
|
6: The enclosure is inactive due to being configured by another
|
|
controller.
|
|
7: The enclosure is offline and inaccessible.
|
|
8: The enclosure is online and accessible.
|
|
9: The enclosure is currently blocked by another controller.
|
|
"
|
|
::= { enclosureTableEntry 4 }
|
|
|
|
enclosureServiceTag OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enclosure identification used when consulting customer support.
|
|
"
|
|
::= { enclosureTableEntry 8 }
|
|
|
|
enclosureAssetTag OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The asset tag information for the enclosure."
|
|
::= { enclosureTableEntry 9 }
|
|
|
|
enclosureConnectedPort OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port on the controller to which the
|
|
storage enclosure is connected.
|
|
"
|
|
::= { enclosureTableEntry 19 }
|
|
|
|
enclosureRollUpStatus OBJECT-TYPE
|
|
SYNTAX ObjectStatusEnum
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Severity of the enclosure/backplane state.
|
|
This is the combined status of the enclosure and its sub-components.
|
|
Possible values:
|
|
1: Other.
|
|
2: Unknown.
|
|
3: OK.
|
|
4: Non-critical.
|
|
5: Critical.
|
|
6: Non-recoverable.
|
|
"
|
|
::= { enclosureTableEntry 23 }
|
|
|
|
enclosureComponentStatus OBJECT-TYPE
|
|
SYNTAX ObjectStatusEnum
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the enclosure/backplane.itself without the
|
|
propagation of any contained component status.
|
|
Possible values:
|
|
1: Other.
|
|
2: Unknown.
|
|
3: OK.
|
|
4: Non-critical .
|
|
5: Critical.
|
|
6: Non-recoverable.
|
|
"
|
|
::= { enclosureTableEntry 24 }
|
|
|
|
enclosureFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware information for the enclosure/backplane.
|
|
"
|
|
::= { enclosureTableEntry 26 }
|
|
|
|
enclosureSASAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The SAS address of the enclosure/backplane.
|
|
"
|
|
::= { enclosureTableEntry 30 }
|
|
|
|
enclosureDriveCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of disks present in the enclosure/backplane.
|
|
"
|
|
::= { enclosureTableEntry 31 }
|
|
|
|
enclosureTotalSlots OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total physical drive slots in a storage enclosure
|
|
or server backplane.
|
|
"
|
|
::= { enclosureTableEntry 32 }
|
|
|
|
enclosureFanCount OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of fans present in the storage enclosure.
|
|
"
|
|
::= { enclosureTableEntry 40 }
|
|
|
|
enclosurePSUCount OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Power Supply Units (PSU) present
|
|
in the storage enclosure.
|
|
"
|
|
::= { enclosureTableEntry 41 }
|
|
|
|
enclosureEMMCount OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Enclosure Management Modules (EMM)
|
|
present in the storage enclosure.
|
|
"
|
|
::= { enclosureTableEntry 42 }
|
|
|
|
enclosureTempProbeCount OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of temperature sensing devices
|
|
present in the storage enclosure.
|
|
"
|
|
::= { enclosureTableEntry 43 }
|
|
|
|
enclosureRedundantPath OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the controller has multiply paths to
|
|
reach the storage enclosure.
|
|
"
|
|
::= { enclosureTableEntry 44 }
|
|
|
|
enclosurePosition OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The possition of the storage enclosure within a daisy chain.
|
|
"
|
|
::= { enclosureTableEntry 45 }
|
|
|
|
enclosureBackplaneBayID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique bay ID of the backplane.
|
|
"
|
|
::= { enclosureTableEntry 46 }
|
|
|
|
enclosureFQDD OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure/backplane's Fully Qualified Device Descriptor (FQDD)
|
|
as represented in Storage Management.
|
|
"
|
|
::= { enclosureTableEntry 47 }
|
|
|
|
enclosureDisplayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure/backplane's friendly FQDD as represented in
|
|
Storage Management.
|
|
"
|
|
::= { enclosureTableEntry 48 }
|
|
|
|
enclosureType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notApplicable(2),
|
|
sassata(3),
|
|
pcie(4),
|
|
universal(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The protocol supported by the backplane.
|
|
Possible states:
|
|
1: Not one of the following or could not be determined.
|
|
2: Not applicable (i.e. object is not a backplane).
|
|
3: Supports SAS/SATA.
|
|
4: Supports PCIe.
|
|
5: Both SAS/SATA and PCIe.
|
|
"
|
|
::= { enclosureTableEntry 49 }
|
|
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Enclosure Management Module Table
|
|
--
|
|
-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.<a>.<i1>
|
|
-------------------------------------------------------------------------------
|
|
|
|
EnclosureManagementModuleTableEntry ::=SEQUENCE {
|
|
enclosureManagementModuleNumber INTEGER,
|
|
enclosureManagementModuleName DisplayString,
|
|
enclosureManagementModuleState INTEGER,
|
|
enclosureManagementModulePartNumber DisplayString,
|
|
enclosureManagementModuleFWVersion DisplayString,
|
|
enclosureManagementModuleComponentStatus ObjectStatusEnum,
|
|
enclosureManagementModuleFQDD FQDDString,
|
|
enclosureManagementModuleDisplayName DisplayString
|
|
}
|
|
|
|
enclosureManagementModuleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EnclosureManagementModuleTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of managed Enclosure Management Modules (EMM)
|
|
in the external storage enclosure(s). The number of
|
|
entries is related to number of enclosure management modules
|
|
discovered in the enclosure(s). The maximum number of entries
|
|
is implementation dependent.
|
|
Note: The properties in this table may not be applicable to all
|
|
entries.
|
|
"
|
|
::= { physicalDevices 13 }
|
|
|
|
enclosureManagementModuleTableEntry OBJECT-TYPE
|
|
SYNTAX EnclosureManagementModuleTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the enclosure management module table. A row in
|
|
this table cannot be created or deleted by SNMP operations
|
|
on columns of the table.
|
|
"
|
|
INDEX { enclosureManagementModuleNumber }
|
|
::= { enclosureManagementModuleTable 1 }
|
|
|
|
enclosureManagementModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Instance number of this enclosure management module.
|
|
"
|
|
::= { enclosureManagementModuleTableEntry 1 }
|
|
|
|
enclosureManagementModuleName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure management module's name as
|
|
represented in Storage Management.
|
|
"
|
|
::= { enclosureManagementModuleTableEntry 2 }
|
|
|
|
enclosureManagementModuleState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
ready(2),
|
|
failed(3),
|
|
missing(4),
|
|
degraded(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of this enclosure management module.
|
|
Possible states:
|
|
1: The current state could not be determined.
|
|
2: The enclosure management module is operating normally.
|
|
3: The enclosure management module has encountered a
|
|
hardware problem or is not responding.
|
|
4: The enclosure management module is no longer connected
|
|
to the enclosure or there exists a problem communicating to it.
|
|
5: The enclosure management module is unstable.
|
|
"
|
|
::= { enclosureManagementModuleTableEntry 4 }
|
|
|
|
enclosureManagementModulePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The part number of the enclosure management module.
|
|
"
|
|
::= { enclosureManagementModuleTableEntry 6 }
|
|
|
|
enclosureManagementModuleFWVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware version of the enclosure management module.
|
|
"
|
|
::= { enclosureManagementModuleTableEntry 8 }
|
|
|
|
enclosureManagementModuleComponentStatus OBJECT-TYPE
|
|
SYNTAX ObjectStatusEnum
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the enclosure management module.itself without the
|
|
propagation of any contained component status.
|
|
Possible values:
|
|
1: Other.
|
|
2: Unknown.
|
|
3: OK.
|
|
4: Non-critical .
|
|
5: Critical.
|
|
6: Non-recoverable.
|
|
"
|
|
::= { enclosureManagementModuleTableEntry 11 }
|
|
|
|
enclosureManagementModuleFQDD OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure management module's Fully Qualified Device
|
|
Descriptor (FQDD) as represented in Storage Management.
|
|
"
|
|
::= { enclosureManagementModuleTableEntry 15 }
|
|
|
|
enclosureManagementModuleDisplayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure management module's friendly FQDD as represented in
|
|
Storage Management.
|
|
"
|
|
::= { enclosureManagementModuleTableEntry 16 }
|
|
|
|
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Enclosure Fan Table
|
|
--
|
|
-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.<a>.<i1>
|
|
-------------------------------------------------------------------------------
|
|
|
|
EnclosureFanTableEntry ::=SEQUENCE {
|
|
enclosureFanNumber INTEGER,
|
|
enclosureFanName DisplayString,
|
|
enclosureFanState INTEGER,
|
|
enclosureFanSpeed INTEGER,
|
|
enclosureFanComponentStatus ObjectStatusEnum,
|
|
enclosureFanFQDD FQDDString,
|
|
enclosureFanDisplayName DisplayString
|
|
}
|
|
|
|
enclosureFanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EnclosureFanTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of managed fans in the external storage enclosure(s).
|
|
The number of entries is related to number of fans discovered in
|
|
the enclosure(s). The maximum number of entries is implementation
|
|
dependent.
|
|
Note: The properties in this table may not be applicable to all
|
|
entries.
|
|
"
|
|
::= { physicalDevices 7 }
|
|
|
|
enclosureFanTableEntry OBJECT-TYPE
|
|
SYNTAX EnclosureFanTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the fan table. A row in this table cannot be
|
|
created or deleted by SNMP operations on columns of the table.
|
|
"
|
|
INDEX { enclosureFanNumber }
|
|
::= { enclosureFanTable 1 }
|
|
|
|
enclosureFanNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Instance number of this fan.
|
|
"
|
|
::= { enclosureFanTableEntry 1 }
|
|
|
|
enclosureFanName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fan's name as represented in Storage Management.
|
|
"
|
|
::= { enclosureFanTableEntry 2 }
|
|
|
|
enclosureFanState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
ready(2),
|
|
failed(3),
|
|
missing(4),
|
|
degraded(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of this fan.
|
|
Possible states:
|
|
1: The current state could not be determined.
|
|
2: The fan is operating normally.
|
|
3: The fan has encountered a hardware problem or is not
|
|
responding.
|
|
4: The fan is no longer connected to the enclosure or
|
|
there exists a problem communicating to it.
|
|
5: The fan is unstable.
|
|
"
|
|
::= { enclosureFanTableEntry 4 }
|
|
|
|
enclosureFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the current relative speed of the fan in RPMs.
|
|
"
|
|
::= { enclosureFanTableEntry 11 }
|
|
|
|
enclosureFanComponentStatus OBJECT-TYPE
|
|
SYNTAX ObjectStatusEnum
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the fan itself without the
|
|
propagation of any contained component status.
|
|
Possible values:
|
|
1: Other.
|
|
2: Unknown.
|
|
3: OK.
|
|
4: Non-critical .
|
|
5: Critical.
|
|
6: Non-recoverable.
|
|
"
|
|
::= { enclosureFanTableEntry 15 }
|
|
|
|
enclosureFanFQDD OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fan's Fully Qualified Device Descriptor (FQDD)
|
|
as represented in Storage Management.
|
|
"
|
|
::= { enclosureFanTableEntry 20 }
|
|
|
|
enclosureFanDisplayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fan's friendly FQDD as represented in
|
|
Storage Management.
|
|
"
|
|
::= { enclosureFanTableEntry 21 }
|
|
|
|
|
|
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Enclosure Power Supply Table
|
|
--
|
|
-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.<a>.<i1>
|
|
-------------------------------------------------------------------------------
|
|
EnclosurePowerSupplyTableEntry ::=SEQUENCE {
|
|
enclosurePowerSupplyNumber INTEGER,
|
|
enclosurePowerSupplyName DisplayString,
|
|
enclosurePowerSupplyState INTEGER,
|
|
enclosurePowerSupplyPartNumber DisplayString,
|
|
enclosurePowerSupplyComponentStatus ObjectStatusEnum,
|
|
enclosurePowerSupplyFQDD FQDDString,
|
|
enclosurePowerSupplyDisplayName DisplayString
|
|
}
|
|
|
|
enclosurePowerSupplyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EnclosurePowerSupplyTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of managed Power Supply Units(PSU) in the external
|
|
storage enclosure(s). The number of entries is related to number
|
|
of power supply unit(s) discovered in the enclosure(s). The
|
|
maximum number of entries is implementation
|
|
dependent.
|
|
Note: The properties in this table may not be applicable to all
|
|
entries.
|
|
"
|
|
::= { physicalDevices 9 }
|
|
|
|
enclosurePowerSupplyTableEntry OBJECT-TYPE
|
|
SYNTAX EnclosurePowerSupplyTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the power supply unit table. A row in this table cannot
|
|
be created or deleted by SNMP operations on columns of the table.
|
|
"
|
|
INDEX { enclosurePowerSupplyNumber }
|
|
::= { enclosurePowerSupplyTable 1 }
|
|
|
|
enclosurePowerSupplyNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Instance number of this power supply unit.
|
|
"
|
|
::= { enclosurePowerSupplyTableEntry 1 }
|
|
|
|
enclosurePowerSupplyName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power supply unit's name as represented in
|
|
Storage Management.
|
|
"
|
|
::= { enclosurePowerSupplyTableEntry 2 }
|
|
|
|
enclosurePowerSupplyState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
ready(2),
|
|
failed(3),
|
|
missing(4),
|
|
degraded(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of this power supply unit.
|
|
Possible states:
|
|
1: The current state could not be determined.
|
|
2: The power supply unit is operating normally.
|
|
3: The power supply unit has encountered a hardware problem
|
|
or is not responding.
|
|
4: The power supply unit is no longer connected to the enclosure
|
|
or there exists a problem communicating to it.
|
|
5: The power supply unit is unstable.
|
|
"
|
|
::= { enclosurePowerSupplyTableEntry 4 }
|
|
|
|
enclosurePowerSupplyPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The part number of the power supply unit.
|
|
"
|
|
::= { enclosurePowerSupplyTableEntry 7 }
|
|
|
|
enclosurePowerSupplyComponentStatus OBJECT-TYPE
|
|
SYNTAX ObjectStatusEnum
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the power supply unit itself without the
|
|
propagation of any contained component status.
|
|
Possible values:
|
|
1: Other.
|
|
2: Unknown.
|
|
3: OK.
|
|
4: Non-critical .
|
|
5: Critical.
|
|
6: Non-recoverable.
|
|
"
|
|
::= { enclosurePowerSupplyTableEntry 9 }
|
|
|
|
enclosurePowerSupplyFQDD OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power supply unit's Fully Qualified Device Descriptor (FQDD)
|
|
as represented in Storage Management.
|
|
"
|
|
::= { enclosurePowerSupplyTableEntry 15 }
|
|
|
|
enclosurePowerSupplyDisplayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power supply unit's friendly FQDD as represented in
|
|
Storage Management.
|
|
"
|
|
::= { enclosurePowerSupplyTableEntry 16 }
|
|
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Enclosure Temperature Probe Table
|
|
--
|
|
-- OID Format:.1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.<a>.<i1>
|
|
-------------------------------------------------------------------------------
|
|
EnclosureTemperatureProbeTableEntry ::=SEQUENCE {
|
|
enclosureTemperatureProbeNumber INTEGER,
|
|
enclosureTemperatureProbeName DisplayString,
|
|
enclosureTemperatureProbeState INTEGER,
|
|
enclosureTemperatureProbeMinWarningValue INTEGER,
|
|
enclosureTemperatureProbeMinCriticalValue INTEGER,
|
|
enclosureTemperatureProbeMaxWarningValue INTEGER,
|
|
enclosureTemperatureProbeMaxCriticalValue INTEGER,
|
|
enclosureTemperatureProbeCurValue INTEGER,
|
|
enclosureTemperatureProbeComponentStatus ObjectStatusEnum,
|
|
enclosureTemperatureProbeFQDD FQDDString,
|
|
enclosureTemperatureProbeDisplayName DisplayString
|
|
}
|
|
|
|
enclosureTemperatureProbeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EnclosureTemperatureProbeTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of managed temperature probes in the external storage
|
|
enclosure(s). The number of entries is related to number of
|
|
temperature probes discovered in the enclosure(s). The maximum
|
|
number of entries is implementation dependent.
|
|
Note: The properties in this table may not be applicable to all
|
|
entries.
|
|
"
|
|
::= { physicalDevices 11 }
|
|
|
|
enclosureTemperatureProbeTableEntry OBJECT-TYPE
|
|
SYNTAX EnclosureTemperatureProbeTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the temperature probe table. A row in this table cannot be
|
|
created or deleted by SNMP operations on columns of the table.
|
|
"
|
|
INDEX { enclosureTemperatureProbeNumber }
|
|
::= { enclosureTemperatureProbeTable 1 }
|
|
|
|
enclosureTemperatureProbeNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Instance number of this temperature probe.
|
|
"
|
|
::= { enclosureTemperatureProbeTableEntry 1 }
|
|
|
|
enclosureTemperatureProbeName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature probe's name as represented in
|
|
Storage Management.
|
|
"
|
|
::= { enclosureTemperatureProbeTableEntry 2 }
|
|
|
|
enclosureTemperatureProbeState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
ready(2),
|
|
failed(3),
|
|
missing(4),
|
|
degraded(5),
|
|
overWarning(6),
|
|
underWarning(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of this temperature probe.
|
|
Possible states:
|
|
1: The current state could not be determined.
|
|
2: The temperature probe is operating normally.
|
|
3: The temperature probe has encountered a hardware problem
|
|
or is not responding.
|
|
4: The temperature probe is no longer connected to the enclosure
|
|
or there exists a problem communicating to it.
|
|
5: The temperature probe is unstable.
|
|
6: The temperature probe is Over Warning Temperature.
|
|
7: The temperature probe is Under Warning Temperature.
|
|
"
|
|
::= { enclosureTemperatureProbeTableEntry 4 }
|
|
|
|
enclosureTemperatureProbeMinWarningValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum temperature that will force the probe into
|
|
a warning state.
|
|
"
|
|
::= { enclosureTemperatureProbeTableEntry 7 }
|
|
|
|
enclosureTemperatureProbeMinCriticalValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum temperature that will force the probe into
|
|
a error state.
|
|
"
|
|
::= { enclosureTemperatureProbeTableEntry 8 }
|
|
|
|
enclosureTemperatureProbeMaxWarningValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum temperature that will force the probe into
|
|
a warning state.
|
|
"
|
|
::= { enclosureTemperatureProbeTableEntry 9 }
|
|
|
|
enclosureTemperatureProbeMaxCriticalValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum temperature that will force the probe into
|
|
a warning state.
|
|
"
|
|
::= { enclosureTemperatureProbeTableEntry 10 }
|
|
|
|
enclosureTemperatureProbeCurValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum temperature that will force the probe into
|
|
a warning state.
|
|
"
|
|
::= { enclosureTemperatureProbeTableEntry 11 }
|
|
|
|
enclosureTemperatureProbeComponentStatus OBJECT-TYPE
|
|
SYNTAX ObjectStatusEnum
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the enclosure management module.itself without the
|
|
propagation of any contained component status.
|
|
Possible values:
|
|
1: Other.
|
|
2: Unknown.
|
|
3: OK.
|
|
4: Non-critical .
|
|
5: Critical.
|
|
6: Non-recoverable.
|
|
"
|
|
::= { enclosureTemperatureProbeTableEntry 13 }
|
|
|
|
enclosureTemperatureProbeFQDD OBJECT-TYPE
|
|
SYNTAX FQDDString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature probe's Fully Qualified Device Descriptor (FQDD)
|
|
as represented in Storage Management.
|
|
"
|
|
::= { enclosureTemperatureProbeTableEntry 15 }
|
|
|
|
enclosureTemperatureProbeDisplayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature probe's friendly FQDD as represented
|
|
in Storage Management.
|
|
"
|
|
::= { enclosureTemperatureProbeTableEntry 16 }
|
|
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: Chassis Alerts 1
|
|
-------------------------------------------------------------------------------
|
|
|
|
drsCASubSystem OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert"
|
|
::= { drsChassisAlertVariables 1 }
|
|
|
|
drsCASSCurrStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0020.0010.0002 This attribute defines the Current Status of the Alerting
|
|
Sub-System"
|
|
::= { drsChassisAlertVariables 2 }
|
|
|
|
drsCASSPrevStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0020.0010.0003 This attribute defines the Previous Status of the Alerting
|
|
Sub-System"
|
|
::= { drsChassisAlertVariables 3 }
|
|
|
|
drsCASSChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of
|
|
the Alerting Sub-System"
|
|
::= { drsChassisAlertVariables 4 }
|
|
|
|
drsCAMessage OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "0020.0010.0005 This attribute defines the CSSD message of the CMC Alert"
|
|
::= { drsChassisAlertVariables 5 }
|
|
|
|
alertCMCTestTrap TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
DESCRIPTION "The CMC has generated a test trap"
|
|
--#TYPE "CMC Test Trap"
|
|
--#SUMMARY "CMC Test Trap"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#CATEGORY Error Events
|
|
::= 2000
|
|
|
|
alertCMCNormalTrap TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsGlobalCurrStatus,
|
|
drsCASubSystem,
|
|
drsCASSCurrStatus,
|
|
drsCASSPrevStatus,
|
|
drsCASSChangeTime,
|
|
drsCAMessage }
|
|
DESCRIPTION "The CMC reported a return-to-normal or informational event."
|
|
--#TYPE "CMC Return-to-Normal / Informational Trap"
|
|
--#SUMMARY "Return-to-Normal / Informational Trap from CMC in system %s in location %s, message: %s"
|
|
--#ARGUMENTS {0,1,7}
|
|
--#SEVERITY NORMAL
|
|
--#CATEGORY Error Events
|
|
::= 2002
|
|
|
|
alertCMCWarningTrap TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsGlobalCurrStatus,
|
|
drsCASubSystem,
|
|
drsCASSCurrStatus,
|
|
drsCASSPrevStatus,
|
|
drsCASSChangeTime,
|
|
drsCAMessage }
|
|
DESCRIPTION "The CMC reported a warning event."
|
|
--#TYPE "CMC Warning Trap"
|
|
--#SUMMARY "Warning Trap from CMC in system %s in location %s, message: %s"
|
|
--#ARGUMENTS {0,1,7}
|
|
--#SEVERITY WARNING
|
|
--#CATEGORY Error Events
|
|
::= 2003
|
|
|
|
alertCMCCriticalTrap TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsGlobalCurrStatus,
|
|
drsCASubSystem,
|
|
drsCASSCurrStatus,
|
|
drsCASSPrevStatus,
|
|
drsCASSChangeTime,
|
|
drsCAMessage }
|
|
DESCRIPTION "The CMC reported a critical event."
|
|
--#TYPE "CMC Critical Trap"
|
|
--#SUMMARY "Critical Trap from CMC in system %s in location %s, message: %s"
|
|
--#ARGUMENTS {0,1,7}
|
|
--#SEVERITY CRITICAL
|
|
--#CATEGORY Error Events
|
|
::= 2004
|
|
|
|
alertCMCNonRecoverableTrap TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsGlobalCurrStatus,
|
|
drsCASubSystem,
|
|
drsCASSCurrStatus,
|
|
drsCASSPrevStatus,
|
|
drsCASSChangeTime,
|
|
drsCAMessage }
|
|
DESCRIPTION "The CMC reported a catastrophic event."
|
|
--#TYPE "CMC Non-Recoverable Trap"
|
|
--#SUMMARY "Non-Recoverable Trap from CMC in system %s in location %s, message: %s"
|
|
--#ARGUMENTS {0,1,7}
|
|
--#SEVERITY NON-RECOVERABLE
|
|
--#CATEGORY Error Events
|
|
::= 2005
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: Chassis Alerts 2
|
|
-------------------------------------------------------------------------------
|
|
|
|
drsCA2MessageID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Message ID of the alert."
|
|
::= { drsChassisAlert2Variables 1 }
|
|
|
|
drsCA2Message OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Message describing the alert."
|
|
::= { drsChassisAlert2Variables 2 }
|
|
|
|
drsCA2MessageArgs OBJECT-TYPE
|
|
SYNTAX DellString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Concatenated set of strings representing any message arguments
|
|
that were used to construct the alert message. Each message
|
|
argument string is enclosed in double quotes, and there is a
|
|
comma after the ending double quote of each message argument
|
|
string, except the last one. Any double quotes found within a
|
|
message argument string were preprocessed and changed to single
|
|
quotes."
|
|
::= { drsChassisAlert2Variables 3 }
|
|
|
|
drsCA2AlertStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Status of the alert."
|
|
::= { drsChassisAlert2Variables 4 }
|
|
|
|
drsCA2FQDD OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..512))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Fully qualified device descriptor of device causing the alert."
|
|
::= { drsChassisAlert2Variables 5 }
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Amperage Probe Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: AMP/16
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2AmperageProbeNormal TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Current sensor reading is within range."
|
|
--#TYPE "System: Amperage Normal"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2179
|
|
|
|
alert2AmperageProbeWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Current sensor has detected a warning value."
|
|
--#TYPE "System: Amperage Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2178
|
|
|
|
alert2AmperageProbeFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Current sensor has detected a failure value."
|
|
--#TYPE "System: Amperage Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2177
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Battery Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: BAT/22
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2BatteryNormal TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Battery state has returned to normal;
|
|
or battery presence had been detected."
|
|
--#TYPE "System: Battery Normal"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2227
|
|
|
|
alert2BatteryWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Battery is low."
|
|
--#TYPE "System: Battery Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2226
|
|
|
|
alert2BatteryFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Battery has failed or battery is absent."
|
|
--#TYPE "System: Battery Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2225
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Cable Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: CBL/43
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2CableFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Cable failure."
|
|
--#TYPE "System: Cable Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2393
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: CMC Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: CMC/62
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2CMCWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Chassis Management Controller detected a warning."
|
|
--#TYPE "System: CMC Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2546
|
|
|
|
alert2CMCFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Chassis Management Controller detected an error."
|
|
--#TYPE "System: CMC Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2545
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Fan Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: FAN/13
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2FanInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Fan information."
|
|
--#TYPE "System: Fan Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2155
|
|
|
|
alert2FanWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Fan warning."
|
|
--#TYPE "System: Fan Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2154
|
|
|
|
alert2FanFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Fan failure."
|
|
--#TYPE "System: Fan Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2153
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Hardware Configuration Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: HWC/35
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2HardwareConfigurationInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Hardware configuration information."
|
|
--#TYPE "System: Hardware Configuration Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2331
|
|
|
|
alert2HardwareConfigurationWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Hardware configuration warning."
|
|
--#TYPE "System: Hardware Configuration Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2330
|
|
|
|
alert2HardwareConfigurationFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Hardware configuration failure or critical event."
|
|
--#TYPE "System: Hardware Configuration Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2329
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: IO Virtualization Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: IOV/63
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2IOVirtualizationInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"IO Virtualization information."
|
|
--#TYPE "System: IO Virtualization Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2555
|
|
|
|
alert2IOVirtualizationWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"IO Virtualization warning."
|
|
--#TYPE "System: IO Virtualization Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2554
|
|
|
|
alert2IOVirtualizationFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"IO Virtualization failure or critical event."
|
|
--#TYPE "System: IO Virtualization Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2553
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Link Status Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: LNK/25
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2LinkStatusInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Link status information."
|
|
--#TYPE "System: Link Status Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2251
|
|
|
|
alert2LinkStatusWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Link status warning."
|
|
--#TYPE "System: Link Status Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2250
|
|
|
|
alert2LinkStatusFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Link status failure or critical event."
|
|
--#TYPE "System: Link Status Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2249
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: PCI Device Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: PCI/46
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PCIDeviceInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"PCI device information."
|
|
--#TYPE "System: PCI Device Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2419
|
|
|
|
alert2PCIDeviceWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"PCI device warning."
|
|
--#TYPE "System: PCI Device Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2418
|
|
|
|
alert2PCIDeviceFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"PCI device failure or critical event."
|
|
--#TYPE "System: PCI Device Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2417
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Power Supply Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: PSU/17
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PowerSupplyNormal TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power supply has returned to normal."
|
|
--#TYPE "System: Power Supply Normal"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2187
|
|
|
|
alert2PowerSupplyWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power supply has detected a warning."
|
|
--#TYPE "System: Power Supply Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2186
|
|
|
|
alert2PowerSupplyFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power supply has detected a failure."
|
|
--#TYPE "System: Power Supply Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2185
|
|
|
|
alert2PowerSupplyRedundancyPolicyChanged TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"PSU redundancy policy changed."
|
|
--#TYPE "System: Power Supply Redundancy policy changed"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 8331
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Power Supply Absent Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: PSUA/52
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PowerSupplyAbsent TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power supply is absent."
|
|
--#TYPE "System: Power Supply Absent"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2465
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Power Usage Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: PWR/28
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PowerUsageInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power usage information."
|
|
--#TYPE "System: Power Usage Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2275
|
|
|
|
alert2PowerUsageWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power usage warning."
|
|
--#TYPE "System: Power Usage Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2274
|
|
|
|
alert2PowerUsageFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power usage failure."
|
|
--#TYPE "System: Power Usage Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2273
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Redundancy Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: RDU/53
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2RedundancyInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Redundancy information."
|
|
--#TYPE "System: Redundancy Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2475
|
|
|
|
alert2RedundancyDegraded TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Redundancy is degraded."
|
|
--#TYPE "System: Redundancy Degraded"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2474
|
|
|
|
alert2RedundancyLost TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Redundancy is lost."
|
|
--#TYPE "System: Redundancy Lost"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2473
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Security Event Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: SEC/42
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SecurityInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Security information."
|
|
--#TYPE "System: Security Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2387
|
|
|
|
alert2SecurityWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Security warning."
|
|
--#TYPE "System: Security Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2386
|
|
|
|
alert2SecurityFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Security failure or critical event."
|
|
--#TYPE "System: Security Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2385
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: System Event Log Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: SEL/41
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SystemEventLogInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"System Event Log information."
|
|
--#TYPE "System: System Event Log Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2379
|
|
|
|
alert2SystemEventLogWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"System Event Log warning."
|
|
--#TYPE "System: System Event Log Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2378
|
|
|
|
alert2SystemEventLogFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"System Event Log failure or critical event."
|
|
--#TYPE "System: System Event Log Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2377
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Software Configuration Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: SWC/36
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SoftwareConfigurationInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Software configuration information."
|
|
--#TYPE "System: Software Configuration Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2339
|
|
|
|
alert2SoftwareConfigurationWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Software configuration warning."
|
|
--#TYPE "System: Software Configuration Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2338
|
|
|
|
alert2SoftwareConfigurationFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Software configuration failure."
|
|
--#TYPE "System: Software Configuration Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2337
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Temperature Probe Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: TMP/14
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2TemperatureProbeNormal TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Temperature sensor value is within range."
|
|
--#TYPE "System: Temperature Normal"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2163
|
|
|
|
alert2TemperatureProbeWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Temperature sensor has detected a warning value."
|
|
--#TYPE "System: Temperature Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2162
|
|
|
|
alert2TemperatureProbeFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Temperature sensor has detected a failure value."
|
|
--#TYPE "System: Temperature Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2161
|
|
|
|
alert2IOMTemperatureExceeded TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"I/O Module <iom slot name> temperature exceeded operating range."
|
|
--#TYPE "System: Temperature Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8305
|
|
|
|
alert2Unable2ReadTemperatureSensors TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Unable to read planar board temperature sensors. The cooling has been increased to safeguard the system."
|
|
--#TYPE "System: Temperature Failure"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8306
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: System: Voltage Probe Traps
|
|
--
|
|
-- Category: System/1
|
|
-- Subcategory: VLT/15
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2VoltageProbeNormal TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Voltage sensor reading is within range."
|
|
--#TYPE "System: Voltage Normal"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 2171
|
|
|
|
alert2VoltageProbeWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Voltage sensor has detected a warning value."
|
|
--#TYPE "System: Voltage Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2170
|
|
|
|
alert2VoltageProbeFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Voltage sensor has detected a failure value."
|
|
--#TYPE "System: Voltage Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 2169
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Battery Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: BAT/22
|
|
-------------------------------------------------------------------------------
|
|
|
|
alert2StorageBatteryInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Battery information."
|
|
--#TYPE "Storage: Battery Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4275
|
|
|
|
alert2StorageBatteryWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Battery warning."
|
|
--#TYPE "Storage: Battery Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 4274
|
|
|
|
alert2StorageBatteryFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Battery failure."
|
|
--#TYPE "Storage: Battery Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS MANDATORY
|
|
::= 4273
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Controller Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: CTL/29
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageControllerInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Controller information."
|
|
--#TYPE "Storage: Controller Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4331
|
|
|
|
alert2StorageControllerWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Controller warning."
|
|
--#TYPE "Storage: Controller Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 4330
|
|
|
|
alert2StorageControllerFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Controller failure."
|
|
--#TYPE "Storage: Controller Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS MANDATORY
|
|
::= 4329
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Enclosure Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: ENC/30
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageEnclosureInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Enclosure information."
|
|
--#TYPE "Storage: Enclosure Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4339
|
|
|
|
alert2StorageEnclosureWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Enclosure warning."
|
|
--#TYPE "Storage: Enclosure Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 4338
|
|
|
|
alert2StorageEnclosureFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Enclosure failure."
|
|
--#TYPE "Storage: Enclosure Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS MANDATORY
|
|
::= 4337
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Fan Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: FAN/13
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageFanInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Fan information."
|
|
--#TYPE "Storage: Fan Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4203
|
|
|
|
alert2StorageFanWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Fan warning."
|
|
--#TYPE "Storage: Fan Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 4202
|
|
|
|
alert2StorageFanFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Fan failure."
|
|
--#TYPE "Storage: Fan Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS MANDATORY
|
|
::= 4201
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Physical Disk Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: PDR/31
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StoragePhysicalDiskInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Physical disk information."
|
|
--#TYPE "Storage: Physical Disk Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4347
|
|
|
|
alert2StoragePhysicalDiskWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Physical disk warning."
|
|
--#TYPE "Storage: Physical Disk Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 4346
|
|
|
|
alert2StoragePhysicalDiskFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Physical disk failure."
|
|
--#TYPE "Storage: Physical Disk Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS MANDATORY
|
|
::= 4345
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Power Supply Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: PSU/17
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StoragePowerSupplyInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Power supply information."
|
|
--#TYPE "Storage: Power Supply Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4235
|
|
|
|
alert2StoragePowerSupplyWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Power supply warning."
|
|
--#TYPE "Storage: Power Supply Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 4234
|
|
|
|
alert2StoragePowerSupplyFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Power supply failure."
|
|
--#TYPE "Storage: Power Supply Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS MANDATORY
|
|
::= 4233
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Security Event Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: SEC/42
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageSecurityInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Security information."
|
|
--#TYPE "Storage: Security Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4435
|
|
|
|
alert2StorageSecurityWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Security warning."
|
|
--#TYPE "Storage: Security Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4434
|
|
|
|
alert2StorageSecurityFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Security failure or critical event."
|
|
--#TYPE "Storage: Security Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4433
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Storage Management Status Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: STOR/10
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageManagementInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Management information.
|
|
There is no global status change associated with this trap."
|
|
--#TYPE "Storage: Storage Management Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4179
|
|
|
|
alert2StorageManagementWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Management has detected a device independent warning
|
|
condition. There is no global status change associated with this
|
|
trap."
|
|
--#TYPE "Storage: Storage Management Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 4178
|
|
|
|
alert2StorageManagementFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Management has detected a device independent error condition.
|
|
There is no global status change associated with this trap."
|
|
--#TYPE "Storage: Storage Management Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS MANDATORY
|
|
::= 4177
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Temperature Probe Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: TMP/14
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageTemperatureProbeInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Temperature probe information."
|
|
--#TYPE "Storage: Temperature Probe Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4211
|
|
|
|
alert2StorageTemperatureProbeWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Temperature probe warning."
|
|
--#TYPE "Storage: Temperature Probe Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 4210
|
|
|
|
alert2StorageTemperatureProbeFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Temperature probe failure."
|
|
--#TYPE "Storage: Temperature Probe Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS MANDATORY
|
|
::= 4209
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Storage: Virtual Disk Traps
|
|
--
|
|
-- Category: Storage/2
|
|
-- Subcategory: VDR/32
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2StorageVirtualDiskInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Virtual disk information."
|
|
--#TYPE "Storage: Virtual Disk Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 4355
|
|
|
|
alert2StorageVirtualDiskWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Virtual disk warning."
|
|
--#TYPE "Storage: Virtual Disk Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 4354
|
|
|
|
alert2StorageVirtualDiskFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Storage Virtual disk failure."
|
|
--#TYPE "Storage: Virtual Disk Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE FAILED
|
|
--#STATUS MANDATORY
|
|
::= 4353
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Updates: Software Change Traps
|
|
--
|
|
-- Category: Updates/3
|
|
-- Subcategory: SWU/21
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SoftwareChangeUpdateWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Software change update warning."
|
|
--#TYPE "Updates: Software Change Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 6314
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: CMC Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: CMC/62
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2CMCAuditInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Chassis Management Controller audit information."
|
|
--#TYPE "Audit: CMC Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 8691
|
|
|
|
alert2CMCAuditWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Chassis Management Controller audit warning."
|
|
--#TYPE "Audit: CMC Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8690
|
|
|
|
alert2CMCAuditFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Chassis Management Controller audit failure or critical event."
|
|
--#TYPE "Audit: CMC Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8689
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: IO Virtualization Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: IOV/63
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2IOVirtualizationAuditWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"IO Virtualization audit warning."
|
|
--#TYPE "Audit: IO Virtualization Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8698
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: License Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: LIC/40
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2LicenseInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"License information."
|
|
--#TYPE "Audit: License Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 8515
|
|
|
|
alert2LicenseWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"License warning."
|
|
--#TYPE "Audit: License Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8514
|
|
|
|
alert2LicenseFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"License failure."
|
|
--#TYPE "Audit: License Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8513
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: PCI Device Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: PCI/46
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PCIDeviceAuditWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"PCI device audit warning."
|
|
--#TYPE "Audit: PCI Device Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8562
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: Power Supply Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: PSU/17
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PowerSupplyAuditWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power Supply audit warning."
|
|
--#TYPE "Audit: Power Supply Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8330
|
|
|
|
alert2PowerSupplyAuditFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power Supply audit failure or critical event."
|
|
--#TYPE "Audit: Power Supply Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8329
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: Power Usage Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: PWR/28
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PowerUsageAuditInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power usage audit information."
|
|
--#TYPE "Audit: Power Usage Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 8419
|
|
|
|
alert2PowerUsageAuditWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power usage audit warning."
|
|
--#TYPE "Audit: Power Usage Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8418
|
|
|
|
alert2PowerUsageAuditFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Power usage audit failure or critical event."
|
|
--#TYPE "Audit: Power Usage Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8417
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Audit: Software Change Traps
|
|
--
|
|
-- Category: Audit/4
|
|
-- Subcategory: SWU/21
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SoftwareChangeAuditFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Software change audit failure or critical event."
|
|
--#TYPE "Audit: Software Change Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 8361
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Configuration: IO Virtualization Traps
|
|
--
|
|
-- Category: Configuration/5
|
|
-- Subcategory: IOV/63
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2IOVConfigurationInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"IO Virtualization configuration information."
|
|
--#TYPE "Configuration: IO Virtualization Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 10747
|
|
|
|
alert2IOVConfigurationWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"IO Virtualization configuration warning."
|
|
--#TYPE "Configuration: IO Virtualization Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 10746
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Configuration: PCI Device Traps
|
|
--
|
|
-- Category: Configuration/5
|
|
-- Subcategory: PCI/46
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2PCIDeviceConfigurationInformation TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"PCI device configuration information."
|
|
--#TYPE "Configuration: PCI Device Information"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 10611
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Configuration: Software Configuration Traps
|
|
--
|
|
-- Category: Configuration/5
|
|
-- Subcategory: SWC/36
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2SWCConfigurationWarning TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Software configuration warning."
|
|
--#TYPE "Configuration: Software Configuration Warning"
|
|
--#SEVERITY MINOR
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 10530
|
|
|
|
alert2SWCConfigurationFailure TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Software configuration failure."
|
|
--#TYPE "Configuration: Software Configuration Failure"
|
|
--#SEVERITY CRITICAL
|
|
--#SUMMARY "Message ID: %s, Message: %s,"
|
|
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
|
|
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
|
|
--#SUMMARY "Chassis Location: %s, Global Status: %d"
|
|
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 6, 8}
|
|
--#CATEGORY "Error Events"
|
|
--#STATE DEGRADED
|
|
--#STATUS MANDATORY
|
|
::= 10529
|
|
|
|
------------------------------------------------------------------------------
|
|
-- Chassis Alerts 2: Configuration: Test Traps
|
|
--
|
|
-- Category: Configuration/5
|
|
-- Subcategory: TST/19
|
|
------------------------------------------------------------------------------
|
|
|
|
alert2CMCTestTrap TRAP-TYPE
|
|
ENTERPRISE drsCMCAlert2Group
|
|
VARIABLES { drsCA2MessageID,
|
|
drsCA2Message,
|
|
drsCA2MessageArgs,
|
|
drsCA2AlertStatus,
|
|
drsCA2FQDD,
|
|
drsProductChassisName,
|
|
drsProductChassisLocation,
|
|
drsChassisServiceTag,
|
|
drsGlobalCurrStatus }
|
|
DESCRIPTION
|
|
"Test trap generated by CMC in response to a user request."
|
|
--#TYPE "Configuration: CMC Test Trap"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {1}
|
|
--#CATEGORY "Status Events"
|
|
--#STATE OPERATIONAL
|
|
--#STATUS MANDATORY
|
|
::= 10395
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- group: Legacy Alerts
|
|
-------------------------------------------------------------------------------
|
|
|
|
drsAlertSystem OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"5000.0010.0001 Name of the system generating the alert."
|
|
--DEFAULT get-function-async get_%n_async
|
|
--DEFAULT next-function-async std_next_async
|
|
::= { drsAlertVariables 1 }
|
|
|
|
drsAlertTableIndexOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"5000.0010.0002 0.0"
|
|
--DEFAULT get-function-async get_OID_null_async
|
|
--DEFAULT next-function-async std_next_async
|
|
::= { drsAlertVariables 2 }
|
|
|
|
drsAlertMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..1024))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"5000.0010.0003 Message describing the alert."
|
|
--DEFAULT get-function-async get_string_null_async
|
|
--DEFAULT next-function-async std_next_async
|
|
::= { drsAlertVariables 3 }
|
|
|
|
drsAlertCurrentStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"5000.0010.0004 Current status of object causing the alert."
|
|
--DEFAULT get-function-async get_dellstatus_unknow_async
|
|
--DEFAULT next-function-async std_next_async
|
|
::= { drsAlertVariables 4 }
|
|
|
|
drsAlertPreviousStatus OBJECT-TYPE
|
|
SYNTAX DellStatus
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"5000.0010.0005 Previous status of object causing the alert."
|
|
--DEFAULT get-function-async get_dellstatus_unknow_async
|
|
--DEFAULT next-function-async std_next_async
|
|
::= { drsAlertVariables 5 }
|
|
|
|
drsAlertData OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..1024))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"5000.0010.0006 Alert data."
|
|
--DEFAULT get-function-async get_string_null_async
|
|
--DEFAULT next-function-async std_next_async
|
|
::= { drsAlertVariables 6 }
|
|
|
|
alertDrscTestTrapEvent TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC generated a test trap event in response to a user request."
|
|
--#TYPE "Dell RAC Test TRAP Event"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#CATEGORY Status Events
|
|
::= 1001
|
|
|
|
alertDrscAuthError TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC Authentication Failures during a time period have Exceeded a Threshold."
|
|
--#TYPE "Dell RAC Authentication Error"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY MINOR
|
|
--#CATEGORY Error Events
|
|
::= 1002
|
|
|
|
alertDrscLostESM TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC cannot communicate with the baseboard management controller (ESM)."
|
|
--#TYPE "Dell RAC Lost Communication with ESM"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY MINOR
|
|
--#CATEGORY Error Events
|
|
::= 1003
|
|
|
|
alertDrscFoundESM TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC is communicating normally with the baseboard management controller (ESM)."
|
|
--#TYPE "Dell RAC Communication with ESM is OK"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#CATEGORY Error Events
|
|
::= 1004
|
|
|
|
alertDrscPowerOff TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC has detected a System power state change to powered-off."
|
|
--#TYPE "Dell RAC Detected System Powered-Off"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY CRITICAL
|
|
--#CATEGORY Error Events
|
|
::= 1005
|
|
|
|
alertDrscPowerOn TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC has detected a system power state change to powered-on."
|
|
--#TYPE "Dell RAC Detected System Powered-On"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#CATEGORY Error Events
|
|
::= 1006
|
|
|
|
alertDrscWatchdogExpired TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC has detected that the system watchdog has expired indicating a system hang."
|
|
--#TYPE "Dell RAC Detected Watchdog Expired"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY CRITICAL
|
|
--#CATEGORY Error Events
|
|
::= 1007
|
|
|
|
alertDrscBattLow TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes."
|
|
--#TYPE "Dell RAC Battery Charge Low"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY MINOR
|
|
--#CATEGORY Error Events
|
|
::= 1008
|
|
|
|
alertDrscTempNormal TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC Temperature probe has retured to a normal value."
|
|
--#TYPE "Dell RAC Temperature Normal"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#CATEGORY Error Events
|
|
::= 1009
|
|
|
|
alertDrscTempWarning TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC Temperature probe has detected a Warning value."
|
|
--#TYPE "Dell RAC Temperature Warning"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY MINOR
|
|
--#CATEGORY Error Events
|
|
::= 1010
|
|
|
|
alertDrscTempCritical TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC Temperature probe has detected a failure (or critical) value."
|
|
--#TYPE "Dell RAC Temperature Failure"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY CRITICAL
|
|
--#CATEGORY Error Events
|
|
::= 1011
|
|
|
|
alertDrscVoltNormal TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC voltage has returned to a normal value."
|
|
--#TYPE "Dell RAC Voltage Normal"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#CATEGORY Error Events
|
|
::= 1012
|
|
|
|
alertDrscVoltWarning TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC voltage probe has detected a warning value."
|
|
--#TYPE "Dell RAC Battery Warning"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY MINOR
|
|
--#CATEGORY Error Events
|
|
::= 1013
|
|
|
|
alertDrscVoltCritical TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC voltage probe has detected a failure (or critical) value."
|
|
--#TYPE "Dell RAC Voltage Failure"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY CRITICAL
|
|
--#CATEGORY Error Events
|
|
::= 1014
|
|
|
|
alertDrscSELWarning TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC has detected a new event in the System Event Log with Severity: Warning."
|
|
--#TYPE "Dell RAC System Event Log Warning"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY MAJOR
|
|
--#CATEGORY Error Events
|
|
::= 1015
|
|
|
|
alertDrscSELCritical TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC has detected a new event in the System Event Log with Severity: Critical."
|
|
--#TYPE "Dell RAC System Event Log Critical"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY CRITICAL
|
|
--#CATEGORY Error Events
|
|
::= 1016
|
|
|
|
alertDrscSEL80percentFull TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC has detected that the System Event Log is 80% full."
|
|
--#TYPE "Dell System Event Log 80% Full Warning"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY MAJOR
|
|
--#CATEGORY Status Events
|
|
::= 1017
|
|
|
|
alertDrscSEL90percentFull TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC has detected that the System Event Log is 90% full."
|
|
--#TYPE " Dell System Event Log 90% Full Warning "
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY MAJOR
|
|
--#CATEGORY Status Events
|
|
::= 1018
|
|
|
|
alertDrscSEL100percentFull TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC has detected that the System Event Log is 100% full."
|
|
--#TYPE " Dell System Event Log 100% Full Warning "
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY MAJOR
|
|
--#CATEGORY Status Events
|
|
::= 1019
|
|
|
|
alertDrscSELNormal TRAP-TYPE
|
|
ENTERPRISE drsOutofBandGroup
|
|
VARIABLES { drsAlertSystem,
|
|
drsAlertTableIndexOID,
|
|
drsAlertMessage,
|
|
drsAlertCurrentStatus,
|
|
drsAlertPreviousStatus,
|
|
drsAlertData }
|
|
DESCRIPTION
|
|
"The RAC has detected a new event in the System Event Log with Severity: Normal."
|
|
--#TYPE "Dell RAC System Event Log Normal"
|
|
--#SUMMARY "%s"
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#CATEGORY Error Events
|
|
::= 1020
|
|
END
|
|
|