- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
405 lines
10 KiB
Text
405 lines
10 KiB
Text
--
|
|
-- Network node MIB for generic resources in any network node (host, gateway,
|
|
-- server etc.)
|
|
--
|
|
|
|
STONESOFT-NETNODE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Unsigned32, Integer32, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString, TimeStamp, DateAndTime
|
|
FROM SNMPv2-TC
|
|
OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF
|
|
stonesoftModules, stonesoftNetworkNode
|
|
FROM STONESOFT-SMI-MIB;
|
|
|
|
stonesoftNetworkNodeMibModule MODULE-IDENTITY
|
|
LAST-UPDATED "201605060000Z"
|
|
ORGANIZATION "Forcepoint LLC"
|
|
CONTACT-INFO "email: mib.stonesoft@forcepoint.com"
|
|
DESCRIPTION "MIB for generic network nodes"
|
|
|
|
REVISION "201605060000Z"
|
|
DESCRIPTION "Company information update"
|
|
|
|
REVISION "201510290000Z"
|
|
DESCRIPTION "Policy upload date added to nodePolicyApplyTime"
|
|
|
|
REVISION "201510150000Z"
|
|
DESCRIPTION "Added last login date to nodeLoginTime"
|
|
|
|
REVISION "201403100000Z"
|
|
DESCRIPTION "Added appliance identification objects"
|
|
|
|
REVISION "200802040000Z"
|
|
DESCRIPTION "Added hardware monitoring objects"
|
|
|
|
|
|
REVISION "200406160000Z"
|
|
DESCRIPTION "First public revision"
|
|
::= { stonesoftModules 4 }
|
|
|
|
netNodeObjects OBJECT IDENTIFIER ::= { stonesoftNetworkNode 1 }
|
|
netNodeEvents OBJECT IDENTIFIER ::= { stonesoftNetworkNode 2 }
|
|
netNodeEventsV2 OBJECT IDENTIFIER ::= { netNodeEvents 0 }
|
|
netNodeConformance OBJECT IDENTIFIER ::= {stonesoftNetworkNode 3 }
|
|
|
|
--
|
|
-- Network node objects, e.g. identifications, state, load
|
|
|
|
nodeClusterId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The identification number of the cluster
|
|
this node belongs to"
|
|
::= { netNodeObjects 1 }
|
|
|
|
|
|
nodeMemberId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Node's member identification within the cluster"
|
|
::= { netNodeObjects 2 }
|
|
|
|
nodeOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
online(1),
|
|
goingOnline(2),
|
|
lockedOnline(3),
|
|
goingLockedOnline(4),
|
|
offline(5),
|
|
goingOffline(6),
|
|
lockedOffline(7),
|
|
goingLockedOffline(8),
|
|
standby(9),
|
|
goingStandby(10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operative (clustering) state of the node"
|
|
::= { netNodeObjects 3 }
|
|
|
|
nodeCPULoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU load percentage on the node"
|
|
::= { netNodeObjects 4 }
|
|
|
|
nodeLastLogin OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The most recent login event on the node"
|
|
::= { netNodeObjects 5 }
|
|
|
|
nodeLastLoginTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timestamp of the most recent login event on the node"
|
|
::= { netNodeObjects 6 }
|
|
|
|
nodeHwmonEvent OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reason for the hardware monitoring event"
|
|
::= { netNodeObjects 8 }
|
|
|
|
nodeApplianceModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Appliance model name"
|
|
::= { netNodeObjects 9 }
|
|
|
|
nodeSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Appliance serial number"
|
|
::= { netNodeObjects 10 }
|
|
|
|
nodePosCode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Appliance POS code"
|
|
::= { netNodeObjects 11 }
|
|
|
|
nodeLoginTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The most recent login event on the node"
|
|
::= { netNodeObjects 12 }
|
|
|
|
nodePolicyApplyTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time when the security policy was installed to the node"
|
|
::= { netNodeObjects 13 }
|
|
|
|
--
|
|
-- Tester objects
|
|
|
|
nodeTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NodeTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains an entry for each
|
|
test instance that was
|
|
configured to send a trap on test failure"
|
|
|
|
::= { netNodeObjects 7 }
|
|
|
|
|
|
nodeTestEntry OBJECT-TYPE
|
|
SYNTAX NodeTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Row for a test instance"
|
|
INDEX { nodeTestIndex }
|
|
::= { nodeTestTable 1 }
|
|
|
|
|
|
NodeTestEntry ::= SEQUENCE {
|
|
nodeTestIndex Unsigned32,
|
|
nodeTestIdentity DisplayString,
|
|
nodeTestResult INTEGER,
|
|
nodeTestResultTime TimeStamp
|
|
}
|
|
|
|
nodeTestIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32(1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Unique positive integer index
|
|
of the nodeTest instance"
|
|
::= { nodeTestEntry 1 }
|
|
|
|
nodeTestIdentity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identification string of a nodeTest"
|
|
::= { nodeTestEntry 2 }
|
|
|
|
|
|
nodeTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER {success(1), failure(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The most recent result of the
|
|
nodeTest"
|
|
::= { nodeTestEntry 3 }
|
|
|
|
nodeTestResultTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The timestamp of the most recent
|
|
result of the nodeTest"
|
|
::= { nodeTestEntry 4 }
|
|
|
|
--
|
|
-- Network node events
|
|
|
|
nodeOnline NOTIFICATION-TYPE
|
|
OBJECTS { nodeOperState }
|
|
STATUS current
|
|
DESCRIPTION "A node has gone to an online state"
|
|
::= { netNodeEventsV2 1 }
|
|
|
|
|
|
nodeOffline NOTIFICATION-TYPE
|
|
OBJECTS { nodeOperState }
|
|
STATUS current
|
|
DESCRIPTION "A node has gone to an offline
|
|
or standby state"
|
|
::= { netNodeEventsV2 2 }
|
|
|
|
nodeBoot NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "A node has booted up"
|
|
::= { netNodeEventsV2 3 }
|
|
|
|
nodeShutdown NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "A node is shutting down"
|
|
::= { netNodeEventsV2 4 }
|
|
|
|
nodeUserLogin NOTIFICATION-TYPE
|
|
OBJECTS { nodeLastLogin }
|
|
STATUS current
|
|
DESCRIPTION "A user has started a login session"
|
|
::= { netNodeEventsV2 5 }
|
|
|
|
nodeFailedUserLogin NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "Failed user login"
|
|
::= { netNodeEventsV2 8 }
|
|
|
|
nodeUserLogout NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "A user has finished session"
|
|
::= { netNodeEventsV2 9 }
|
|
|
|
nodeTestFailure NOTIFICATION-TYPE
|
|
OBJECTS { nodeTestIdentity }
|
|
STATUS current
|
|
DESCRIPTION "NodeTest has failed"
|
|
::= { netNodeEventsV2 6 }
|
|
|
|
|
|
nodeHwmon NOTIFICATION-TYPE
|
|
OBJECTS { nodeHwmonEvent }
|
|
STATUS current
|
|
DESCRIPTION "Hardware monitoring system has detected problems"
|
|
::= { netNodeEventsV2 7 }
|
|
|
|
|
|
-- Conformance information
|
|
|
|
netNodeGroups OBJECT IDENTIFIER ::= { netNodeConformance 1 }
|
|
netNodeCompliances OBJECT IDENTIFIER ::= { netNodeConformance 2 }
|
|
|
|
nodeCompliance1 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for network nodes"
|
|
MODULE -- this module --
|
|
MANDATORY-GROUPS { nodeStatusGroup,
|
|
nodeStatusNotificationsGroup }
|
|
|
|
GROUP nodeIdentificationGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for nodes that are part of a cluster"
|
|
|
|
GROUP nodeLoginGroup
|
|
DESCRIPTION
|
|
"This group should be implemented by the nodes that
|
|
allow user logins"
|
|
|
|
GROUP nodeLoginNotificationsGroup
|
|
DESCRIPTION
|
|
"This group should be implemented by the nodes that
|
|
allow user logins"
|
|
|
|
GROUP nodeTesterGroup
|
|
DESCRIPTION
|
|
"This group should be implemented by the nodes that
|
|
have a tester subsystem"
|
|
|
|
GROUP nodeTesterNotificationsGroup
|
|
DESCRIPTION
|
|
"This group should be implemented by the nodes that
|
|
have a tester subsystem"
|
|
|
|
GROUP nodeHwmonGroup
|
|
DESCRIPTION
|
|
"This group should be implemented by the nodes that
|
|
have a hardware monitoring subsystem"
|
|
|
|
|
|
GROUP nodeHwmonNotificationsGroup
|
|
DESCRIPTION
|
|
"This group should be implemented by the nodes that
|
|
have a hardware monitoring subsystem"
|
|
|
|
::= { netNodeCompliances 1 }
|
|
|
|
|
|
|
|
nodeIdentificationGroup OBJECT-GROUP
|
|
OBJECTS { nodeClusterId, nodeMemberId, nodeApplianceModel, nodeSerialNumber, nodePosCode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects identifying the node in a cluster"
|
|
::= { netNodeGroups 1 }
|
|
|
|
nodeStatusGroup OBJECT-GROUP
|
|
OBJECTS { nodeOperState, nodeCPULoad, nodePolicyApplyTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects giving information about
|
|
the status of the node"
|
|
::= { netNodeGroups 2 }
|
|
|
|
nodeLoginGroup OBJECT-GROUP
|
|
OBJECTS { nodeLastLogin, nodeLastLoginTime, nodeLoginTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects giving information about logins
|
|
into the node"
|
|
::= { netNodeGroups 3 }
|
|
|
|
nodeTesterGroup OBJECT-GROUP
|
|
OBJECTS { nodeTestIdentity, nodeTestResult, nodeTestResultTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects giving information about the tests
|
|
in the test subsystem of the node"
|
|
::= { netNodeGroups 4 }
|
|
|
|
nodeHwmonGroup OBJECT-GROUP
|
|
OBJECTS { nodeHwmonEvent }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects giving information about
|
|
hardware monitoring events in the node"
|
|
::= { netNodeGroups 8 }
|
|
|
|
nodeStatusNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { nodeOnline, nodeOffline, nodeBoot, nodeShutdown }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of notifications informing about changes
|
|
in a node's status"
|
|
::= { netNodeGroups 5 }
|
|
|
|
nodeLoginNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { nodeUserLogin, nodeFailedUserLogin, nodeUserLogout }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of notifications informing about user logins"
|
|
::= { netNodeGroups 6 }
|
|
|
|
nodeTesterNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { nodeTestFailure }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of notifications informing about test failures"
|
|
::= { netNodeGroups 7 }
|
|
|
|
|
|
nodeHwmonNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { nodeHwmon }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of notifications informing about
|
|
hardware monitoring issues"
|
|
::= { netNodeGroups 9 }
|
|
|
|