- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
2896 lines
146 KiB
Text
2896 lines
146 KiB
Text
-- File Name : SPC200.txt
|
||
|
||
-- Date : Wed Aug 23 14:03:00 CEST 2006
|
||
-- Author : Gilles Marceau
|
||
|
||
-- Date : Tue Jul 06 18:48:54 CEST 2004
|
||
-- Author : Luc Capanaccia
|
||
|
||
-- Date : Tue Jul 22 12:00:00 CEST 2004
|
||
-- Reviewed by : Gilles Dupont
|
||
|
||
-- Date : Mon Sep 13 12:00:00 CEST 2004
|
||
-- Reviewed by : Gilles Dupont
|
||
|
||
-- Date : Mon Sep 21 12:00:00 CEST 2004
|
||
-- Reviewed by : Gilles Dupont
|
||
|
||
-- Date : Tue Nov 16 12:30:00 CEST 2004
|
||
-- Reviewed by : Luc Capanaccia
|
||
|
||
-- Date : Fri Dec 17 12:30:00 CEST 2004
|
||
-- Reviewed by : Luc Capanaccia
|
||
|
||
-- Date : Thu Sep 15 14:00:00 CEST 2005
|
||
-- Reviewed by : Philippe Rimauro (Tag PR01)
|
||
|
||
-- Date : Thu Feb 08 14:03:00 CEST 2007
|
||
-- Author : Gilles Marceau
|
||
|
||
SPC200 DEFINITIONS ::= BEGIN
|
||
IMPORTS
|
||
RowStatus, TruthValue, MacAddress, DisplayString, TEXTUAL-CONVENTION
|
||
FROM SNMPv2-TC
|
||
AGENT-CAPABILITIES, OBJECT-GROUP, MODULE-COMPLIANCE
|
||
FROM SNMPv2-CONF
|
||
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32,
|
||
Counter32, IpAddress, Unsigned32, Gauge32
|
||
FROM SNMPv2-SMI
|
||
interfaces, ifIndex
|
||
FROM IF-MIB
|
||
spidcom
|
||
FROM SPIDCOM-MIB;
|
||
|
||
spc200MIB MODULE-IDENTITY
|
||
|
||
LAST-UPDATED "200412171230Z" -- December 17, 2004
|
||
|
||
ORGANIZATION "Organization"
|
||
CONTACT-INFO "Contact-info"
|
||
DESCRIPTION "Description"
|
||
|
||
REVISION "200412171230Z"
|
||
DESCRIPTION "Add software upgrade features"
|
||
|
||
REVISION "200411161230Z"
|
||
DESCRIPTION "Add adapt level table , commit and reset command"
|
||
|
||
REVISION "200409211200Z"
|
||
DESCRIPTION "Add quick access to channel modulation and pilots"
|
||
|
||
REVISION "200409131200Z"
|
||
DESCRIPTION "Add quick access to notches"
|
||
|
||
REVISION "200407221200Z"
|
||
DESCRIPTION "Corrected compilation errors"
|
||
|
||
REVISION "200407011757Z"
|
||
DESCRIPTION "Initial revision"
|
||
|
||
::= { spidcom 1 }
|
||
|
||
-- TEXTUAL-CONVENTIONS --
|
||
ModulationValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Modulation amplitude used by a group of carriers."
|
||
SYNTAX INTEGER { none ( 1 ) ,
|
||
bpsk ( 2 ) ,
|
||
qpsk ( 3 ) ,
|
||
qam16 ( 4 ) ,
|
||
qam64 ( 5 ) ,
|
||
qam256 ( 6 ) }
|
||
|
||
CarrierValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A group is composed of 8 carriers."
|
||
SYNTAX Integer32 ( 1 .. 8 )
|
||
|
||
PilotValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The pilot carrier wave can be chosen between
|
||
the carrier 1 up to carrier 128 inside a band carrier range."
|
||
SYNTAX Integer32 ( 1 .. 128 )
|
||
|
||
BandValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A channel is composed of 7 bands."
|
||
SYNTAX Integer32 ( 1 .. 7 )
|
||
|
||
PlcChannelType ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The different type of plc channels:
|
||
rx for the current reception channel,
|
||
rx last for the last reception channel,
|
||
tx for the current transmission channel."
|
||
SYNTAX INTEGER { rx ( 1 ) ,
|
||
rxLast ( 2 ) ,
|
||
tx ( 3 ) }
|
||
|
||
EstimationMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of Channel estimation process. Two are available:
|
||
- automatic, the equipment negociates the best configuration
|
||
with the remote equipment,
|
||
- manual, the operator defines the configuration."
|
||
SYNTAX INTEGER { automatic ( 1 ) ,
|
||
manual ( 2 ) }
|
||
|
||
GroupValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A band is composed of 16 groups."
|
||
SYNTAX Integer32 ( 1 .. 16 )
|
||
|
||
ResultValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Result value of input vectors."
|
||
SYNTAX INTEGER { success ( 1 ) ,
|
||
fail ( 2 ) }
|
||
|
||
AdaptValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The adapt level integer value."
|
||
SYNTAX Integer32 ( 0 .. 8191 )
|
||
|
||
ChannelBandwidthValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The channel bandwidth integer value."
|
||
SYNTAX Integer32 --PR01
|
||
|
||
SoftwareIndex ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The software index."
|
||
SYNTAX Integer32 ( 1 .. 10 )
|
||
|
||
SoftwareActionResultValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Result value of software action process."
|
||
SYNTAX INTEGER { success ( 0 ) ,
|
||
on-going ( 1 ) ,
|
||
fileNotExist ( 2 ) ,
|
||
flashExhausted ( 3 ),
|
||
flashCorrupted ( 4 ),
|
||
notEnoughMemory ( 5 ),
|
||
invalidParameter ( 6 ),
|
||
genericError ( 7 ) }
|
||
|
||
SoftwareActionType ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Type of software management action."
|
||
SYNTAX INTEGER { switch ( 1 ) ,
|
||
remove ( 2 ) }
|
||
|
||
--PR01 BEGIN
|
||
PlcModeType ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Type of software management action."
|
||
SYNTAX INTEGER { ad-hoc ( 0 ) ,
|
||
slave ( 1 ) ,
|
||
master ( 2 ) }
|
||
--PR01 END
|
||
|
||
-- PLC data
|
||
|
||
plc OBJECT IDENTIFIER
|
||
::= { spc200MIB 1 }
|
||
|
||
-- statistic data
|
||
|
||
stats OBJECT IDENTIFIER
|
||
::= { plc 1 }
|
||
--PR01 BEGIN
|
||
-- protocol OBJECT IDENTIFIER
|
||
-- ::= { stats 1 }
|
||
|
||
-- ip OBJECT IDENTIFIER
|
||
-- ::= { protocol 1 }
|
||
|
||
-- mac OBJECT IDENTIFIER
|
||
-- ::= { protocol 2 }
|
||
|
||
-- plcp OBJECT IDENTIFIER
|
||
-- ::= { protocol 3 }
|
||
|
||
-- ipStatsTable OBJECT-TYPE
|
||
-- SYNTAX SEQUENCE OF IpStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This table gathers all statistic data specific to
|
||
-- SPC200 chip relative to IP protocol. The data is
|
||
-- relative to the underlying interface that is under
|
||
-- the IP protocol layer. So the table index is
|
||
-- the ifIndex of such an interface."
|
||
-- ::= { ip 1 }
|
||
|
||
-- ipStatsEntry OBJECT-TYPE
|
||
-- SYNTAX IpStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This row contains IP statistic data specific to
|
||
-- SPC200 chip. The data is relevant for the interface
|
||
-- under the IP protocol layer."
|
||
-- INDEX { ifIndex }
|
||
-- ::= { ipStatsTable 1 }
|
||
|
||
-- IpStatsEntry ::= SEQUENCE {
|
||
-- ipInPkts Counter32,
|
||
-- ipInErrorPkts Counter32,
|
||
-- ipOutPkts Counter32,
|
||
-- ipOutErrorPkts Counter32,
|
||
-- ipInBridgedPkts Counter32
|
||
-- }
|
||
|
||
|
||
-- ipInPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of IP packets received by the interface
|
||
-- associated with this entry"
|
||
-- ::= { ipStatsEntry 1 }
|
||
|
||
|
||
-- ipInErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of inbound IP packets that contained
|
||
-- errors preventing them from being deliverable to a
|
||
-- higher -layer protocol on the interface associated
|
||
-- with this entry."
|
||
-- ::= { ipStatsEntry 2 }
|
||
|
||
|
||
-- ipOutPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of outbound IP packets transmitted
|
||
-- out the interface associated with this entry"
|
||
-- ::= { ipStatsEntry 3 }
|
||
|
||
|
||
-- ipOutErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of outbound IP packets that could not be
|
||
-- transmitted because of errors."
|
||
-- ::= { ipStatsEntry 4 }
|
||
|
||
|
||
-- ipInBridgedPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of IP packets bridged from the interface,
|
||
-- associated with this entry, and another one"
|
||
-- ::= { ipStatsEntry 5 }
|
||
|
||
-- ipInPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of IP packets received
|
||
-- by the SPC200 CHIP"
|
||
-- ::= { ip 2 }
|
||
|
||
-- ipInErrorPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of inbound IP packets that
|
||
-- contained errors preventing them from being delivered."
|
||
-- ::= { ip 3 }
|
||
|
||
-- ipOutPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of outbound IP packets transmitted
|
||
-- out the interfaces"
|
||
-- ::= { ip 4 }
|
||
|
||
-- ipOutErrorPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of outbound IP packets that could
|
||
-- not be transmitted because of errors."
|
||
-- ::= { ip 5 }
|
||
|
||
-- ipBridgedPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of IP packets bridged"
|
||
-- ::= { ip 6 }
|
||
|
||
-- macStatsTable OBJECT-TYPE
|
||
-- SYNTAX SEQUENCE OF MacStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This table gathers all SPC200 chip specific packet
|
||
-- statistics relative to MAC layer.
|
||
-- The data is relative to the underlying interface
|
||
-- that is under the MAC layer. So the table index is
|
||
-- the ifIndex of such an interface."
|
||
-- ::= { mac 1 }
|
||
|
||
-- macStatsEntry OBJECT-TYPE
|
||
-- SYNTAX MacStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This row contains MAC statistic data specific
|
||
-- to SPC200 chip. The data is relevant for the interface
|
||
-- under the MAC layer."
|
||
-- INDEX { ifIndex }
|
||
-- ::= { macStatsTable 1 }
|
||
--
|
||
-- MacStatsEntry ::= SEQUENCE {
|
||
-- macInPkts Counter32,
|
||
-- macInErrorPkts Counter32,
|
||
-- macOutPackets Counter32,
|
||
-- macOutErrorPkts Counter32
|
||
-- }
|
||
|
||
|
||
-- macInPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of MAC packets received by the interface
|
||
-- associated with this entry"
|
||
-- ::= { macStatsEntry 1 }
|
||
--
|
||
--
|
||
-- macInErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of inbound MAC packets that contained
|
||
-- errors preventing them from being deliverable to
|
||
-- a higher -layer protocol on the interface
|
||
-- associated with this entry."
|
||
-- ::= { macStatsEntry 2 }
|
||
|
||
|
||
-- macOutPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of outbound MAC packets transmitted
|
||
-- out the interface associated with this entry"
|
||
-- ::= { macStatsEntry 3 }
|
||
|
||
|
||
-- macOutErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of outbound MAC packets that could not be
|
||
-- transmitted because of errors."
|
||
-- ::= { macStatsEntry 4 }
|
||
|
||
-- plcpStatsTable OBJECT-TYPE
|
||
-- SYNTAX SEQUENCE OF PlcpStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This table gathers all SPC200 chip specific packet
|
||
-- statistics relative to PLCP protocol.
|
||
-- The data is relative to the underlying interface that
|
||
-- is under the PLCP protocol layer. So the table index
|
||
-- is the ifIndex of such an interface."
|
||
-- ::= { plcp 1 }
|
||
|
||
-- plcpStatsEntry OBJECT-TYPE
|
||
-- SYNTAX PlcpStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This row contains PLCP statistic data specific
|
||
-- to SPC200 chip. The data is relevant for the interface
|
||
-- under the PLCP layer."
|
||
-- INDEX { ifIndex }
|
||
-- ::= { plcpStatsTable 1 }
|
||
|
||
-- PlcpStatsEntry ::= SEQUENCE {
|
||
-- plcpInPkts Counter32,
|
||
-- plcpInErrorPkts Counter32,
|
||
-- plcpOutPkts Counter32,
|
||
-- plcpOutErrorPkts Counter32
|
||
-- }
|
||
|
||
|
||
-- plcpInPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of PLCP packets received by the interface
|
||
-- associated with this entry"
|
||
-- ::= { plcpStatsEntry 1 }
|
||
|
||
|
||
-- plcpInErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of inbound PLCP packets that contained
|
||
-- errors preventing them from being deliverable to a
|
||
-- higher -layer protocol on the interface associated
|
||
-- with this entry."
|
||
-- ::= { plcpStatsEntry 2 }
|
||
|
||
|
||
-- plcpOutPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of outbound PLCP packets transmitted
|
||
-- out the interface associated with this entry"
|
||
-- ::= { plcpStatsEntry 3 }
|
||
|
||
|
||
-- plcpOutErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of outbound PLCP packets that could not be
|
||
-- transmitted because of errors."
|
||
-- ::= { plcpStatsEntry 4 }
|
||
--PR01 END
|
||
|
||
|
||
portStatsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PortStatsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table gathers all statistic data specific
|
||
to SPC200 chip relative to plc connection."
|
||
::= { stats 2 }
|
||
|
||
portStatsEntry OBJECT-TYPE
|
||
SYNTAX PortStatsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains statistic data specific to
|
||
SPC200 chip relative to a connection."
|
||
INDEX { plcBasePortIndex,
|
||
portStatsBandIndex,
|
||
portStatsGroupIndex,
|
||
portStatsCarrierIndex }
|
||
::= { portStatsTable 1 }
|
||
|
||
PortStatsEntry ::= SEQUENCE {
|
||
portStatsBandIndex BandValue,
|
||
portStatsGroupIndex GroupValue,
|
||
portStatsCarrierIndex CarrierValue,
|
||
portStatsSignal Counter32,
|
||
portStatsNoise Counter32
|
||
-- portStatsBer Counter32
|
||
}
|
||
|
||
|
||
portStatsBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the signal,
|
||
noise, ber data are collected."
|
||
::= { portStatsEntry 1 }
|
||
|
||
|
||
portStatsGroupIndex OBJECT-TYPE
|
||
SYNTAX GroupValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the signal,
|
||
noise, ber data are collected"
|
||
::= { portStatsEntry 2 }
|
||
|
||
|
||
portStatsCarrierIndex OBJECT-TYPE
|
||
SYNTAX CarrierValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the signal,
|
||
noise, ber data are collected"
|
||
::= { portStatsEntry 3 }
|
||
|
||
|
||
portStatsSignal OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The DB value of the signal associated
|
||
with the carrier wave entry."
|
||
::= { portStatsEntry 4 }
|
||
|
||
|
||
portStatsNoise OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The DB value of the noise associated
|
||
with the carrier wave entry."
|
||
::= { portStatsEntry 5 }
|
||
--PR01 BEGIN
|
||
-- portStatsBer OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The BER value * 100 associated
|
||
-- with the carrier wave entry."
|
||
-- ::= { portStatsEntry 6 }
|
||
--PR01 END
|
||
|
||
portStats2Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PortStats2Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table gathers all statistic data specific to
|
||
SPC200 chip relative to plc channels. This table has
|
||
the same information as the portChannelStatsTable
|
||
but in a more compact way. This table has been added
|
||
to deal with possible slow performances."
|
||
::= { stats 3 }
|
||
|
||
portStats2Entry OBJECT-TYPE
|
||
SYNTAX PortStats2Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains statistic data specific to
|
||
SPC200 chip relative to a connection."
|
||
INDEX { plcBasePortIndex,
|
||
plcModBandIndex }
|
||
::= { portStats2Table 1 }
|
||
|
||
PortStats2Entry ::= SEQUENCE {
|
||
portStats2Signal OCTET STRING,
|
||
portStats2Noise OCTET STRING,
|
||
|
||
|
||
--PR01 BEGIN
|
||
-- portStats2Ber OCTET STRING,
|
||
portStats2AvgBandAtt Counter32,
|
||
portStats2AvgBandSNR Counter32
|
||
--PR01 END
|
||
}
|
||
|
||
|
||
portStats2Signal OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The values of the signal for all the carrier waves.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is coded on two bytes.
|
||
There is one value for each 128 carriers of the
|
||
considered band."
|
||
::= { portStats2Entry 1 }
|
||
|
||
|
||
portStats2Noise OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The values of the noise for all the carrier waves.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is coded on two bytes.
|
||
There is one value for each 128 carriers of the
|
||
considered band."
|
||
::= { portStats2Entry 2 }
|
||
|
||
-- portStats2Ber OBJECT-TYPE
|
||
-- SYNTAX OCTET STRING
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The values of the signal for all the carrier waves.
|
||
-- The expected format is VALUE VALUE VALUE ... VALUE.
|
||
-- Each value is coded on two bytes.
|
||
-- There is one value for each 128 carriers of the
|
||
-- considered band.
|
||
-- The VALUE represents the BER value * 10000."
|
||
-- ::= { portStats2Entry 3 }
|
||
|
||
--PR01 BEGIN
|
||
portStats2AvgBandAtt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Average attenuation per band (dB)."
|
||
::= { portStats2Entry 3 }
|
||
|
||
|
||
portStats2AvgBandSNR OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Average SNR per band (dB)."
|
||
::= { portStats2Entry 4 }
|
||
--PR01 END
|
||
--PR01 BEGIN
|
||
portStats3Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PortStats3Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table gathers all statistic data specific to
|
||
SPC200 chip relative to plc channels. This table has
|
||
the same information as the portChannelStatsTable
|
||
but in a more compact way. This table has been added
|
||
to deal with possible slow performances."
|
||
::= { stats 4 }
|
||
|
||
portStats3Entry OBJECT-TYPE
|
||
SYNTAX PortStats3Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains statistic data specific to
|
||
SPC200 chip relative to a connection."
|
||
INDEX { plcBasePortIndex }
|
||
::= { portStats3Table 1 }
|
||
|
||
PortStats3Entry ::= SEQUENCE {
|
||
portStats3AvgAtt Counter32,
|
||
portStats3AvgSNR Counter32
|
||
}
|
||
|
||
portStats3AvgAtt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Average attenuation on the link (dB)."
|
||
::= { portStats3Entry 1 }
|
||
|
||
portStats3AvgSNR OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Average SNR on the link (dB)."
|
||
::= { portStats3Entry 2 }
|
||
|
||
bootstats OBJECT-IDENTITY
|
||
STATUS current
|
||
DESCRIPTION "boot statistics"
|
||
::= { stats 5 }
|
||
|
||
bootstatsBoot OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Boot"
|
||
::= { bootstats 1 }
|
||
|
||
bootstatsManualReset OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Manual reset"
|
||
::= { bootstats 2 }
|
||
|
||
bootstatsFailureReset OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Failure reset"
|
||
::= { bootstats 3 }
|
||
|
||
--PR01 END
|
||
|
||
-- configuration data
|
||
plcObjects OBJECT IDENTIFIER
|
||
::= { plc 2 }
|
||
|
||
plcMode OBJECT-TYPE -- PR01
|
||
SYNTAX PlcModeType --PR01
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Plc Mode"
|
||
::= { plcObjects 1 }
|
||
|
||
plcTopo OBJECT IDENTIFIER
|
||
::= { plcObjects 2 }
|
||
|
||
plcNodeConfiguration OBJECT IDENTIFIER
|
||
::= { plcObjects 3 }
|
||
|
||
--PR01 BEGIN
|
||
plcSNAnalyser OBJECT IDENTIFIER
|
||
::= { plcObjects 4 }
|
||
|
||
plcSNAnalyserEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { true ( 1 ) ,
|
||
false ( 2 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "true if the modem should turn to spectrum analyser mode.
|
||
In this mode the modem enters a receive only mode,
|
||
and captures periodic samples of the signal on the powerline.
|
||
The spectrum analyser mode shall be disabled for normal
|
||
powerline modem operation."
|
||
::= { plcSNAnalyser 1 }
|
||
|
||
plcSNAnalyserTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcSNAnalyserEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table gathers all statistic data specific to
|
||
SPC200 chip relative to plc analyser."
|
||
::= { plcSNAnalyser 2 }
|
||
|
||
plcSNAnalyserEntry OBJECT-TYPE
|
||
SYNTAX PlcSNAnalyserEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains statistic data specific to
|
||
SPC200 chip relative to a band."
|
||
INDEX { plcModBandIndex }
|
||
::= { plcSNAnalyserTable 1 }
|
||
|
||
PlcSNAnalyserEntry ::= SEQUENCE {
|
||
plcSNAnalyserMinSignal OCTET STRING,
|
||
plcSNAnalyserMaxSignal OCTET STRING,
|
||
plcSNAnalyserAvgSignal OCTET STRING,
|
||
plcSNAnalyserLastSignal OCTET STRING,
|
||
plcSNAnalyserFFTDiv Counter32
|
||
}
|
||
|
||
plcSNAnalyserMinSignal OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Minimum signal measured over several samples for the
|
||
associated carrier wave entry. The value is expressed
|
||
in Glomer<65> which can be converted in dBm/Hz using the
|
||
following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
|
||
::= { plcSNAnalyserEntry 1 }
|
||
|
||
|
||
plcSNAnalyserMaxSignal OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Maximum signal measured on several samples for the
|
||
associated carrier wave entry. The value is expressed
|
||
in Glomer<65> which can be converted in dBm/Hz using the
|
||
following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
|
||
::= { plcSNAnalyserEntry 2 }
|
||
|
||
|
||
plcSNAnalyserAvgSignal OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Average signal measured on several samples for the
|
||
associated carrier wave entry. The value is expressed
|
||
in Glomer<65> which can be converted in dBm/Hz using the
|
||
following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
|
||
::= { plcSNAnalyserEntry 3 }
|
||
|
||
plcSNAnalyserLastSignal OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Signal measured for last sample on the associated
|
||
carrier wave entry. The value is expressed
|
||
in Glomer<65> which can be converted in dBm/Hz using the
|
||
following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
|
||
::= { plcSNAnalyserEntry 4 }
|
||
|
||
plcSNAnalyserFFTDiv OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "FFT division factor on the associated band."
|
||
::= { plcSNAnalyserEntry 5 }
|
||
|
||
plcSNAnalyserAGC OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0..255 )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Gain factor in dB, as used by the
|
||
Automatic Gain Control last sample"
|
||
::= { plcSNAnalyser 3 }
|
||
|
||
|
||
plcAGCAnalyser OBJECT IDENTIFIER
|
||
::= { plcObjects 5 }
|
||
|
||
plcAGCAnalyserEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { true ( 1 ) ,
|
||
false ( 2 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION " "
|
||
::= { plcAGCAnalyser 1 }
|
||
|
||
plcAGCAnalyserSamplesPart1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION " "
|
||
::= { plcAGCAnalyser 2 }
|
||
|
||
plcAGCAnalyserSamplesPart2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION " "
|
||
::= { plcAGCAnalyser 3 }
|
||
--PR01 END
|
||
|
||
plcTopoChanges OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The total number of topology changes detected
|
||
by this plc bridge since the management entity
|
||
was last reset or initialized. Such changes
|
||
concerns only
|
||
- the plcBasePortTable rows
|
||
- the plcBasePortTable columns
|
||
except for plcBasePortChannelEstimation"
|
||
::= { plcTopo 1 }
|
||
|
||
plcBasePortTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcBasePortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains the list of plc remote connection"
|
||
::= { plcTopo 2 }
|
||
|
||
plcBasePortEntry OBJECT-TYPE
|
||
SYNTAX PlcBasePortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains plc remote connection information"
|
||
INDEX { plcBasePortIndex }
|
||
::= { plcBasePortTable 1 }
|
||
|
||
PlcBasePortEntry ::= SEQUENCE {
|
||
plcBasePortIndex MacAddress,
|
||
plcBasePortAddress MacAddress,
|
||
plcBasePortChannelEstimation EstimationMode,
|
||
plcBasePortAttenuation Counter32 }
|
||
|
||
|
||
plcBasePortIndex OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The MAC address of the MAC layer above
|
||
the plc interface of the remote PLC equipment."
|
||
::= { plcBasePortEntry 1 }
|
||
|
||
|
||
plcBasePortAddress OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The MAC address of the MAC layer above
|
||
the plc interface of the remote PLC equipment."
|
||
::= { plcBasePortEntry 2 }
|
||
|
||
|
||
plcBasePortChannelEstimation OBJECT-TYPE
|
||
SYNTAX EstimationMode
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Enable or disable the automatic channel
|
||
estimation processus."
|
||
::= { plcBasePortEntry 3 }
|
||
|
||
plcBasePortAttenuation OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Link attenuation (dB)."
|
||
::= { plcBasePortEntry 4 }
|
||
|
||
|
||
plcChannelModulationStringTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcChannelModulationStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains string values for a quick access to
|
||
the modulation amplitude configurations of all active
|
||
channels."
|
||
::= { plcTopo 3 }
|
||
|
||
|
||
plcChannelModulationStringEntry OBJECT-TYPE
|
||
SYNTAX PlcChannelModulationStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains string values for a quick access to
|
||
the modulation amplitude configuration
|
||
of each active channel of the remote
|
||
connection referenced by plcBasePortIndex."
|
||
INDEX { plcBasePortIndex }
|
||
::= { plcChannelModulationStringTable 1 }
|
||
|
||
|
||
PlcChannelModulationStringEntry ::= SEQUENCE {
|
||
plcRxChannelModulation OCTET STRING,
|
||
plcRxLastChannelModulation OCTET STRING,
|
||
plcTxChannelModulation OCTET STRING }
|
||
|
||
|
||
plcRxChannelModulation OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude values for the Rx channel of
|
||
a given remote connection entry.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is an octet representing two modulation values.
|
||
Each modulation is coded on 4 bits.
|
||
There are ( 16 groups * 7 bands ) / 2 = 66 values."
|
||
::= { plcChannelModulationStringEntry 1 }
|
||
|
||
|
||
plcRxLastChannelModulation OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude values for the Rx Last channel of
|
||
a given remote connection entry.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is an octet representing two modulation values.
|
||
Each modulation is coded on 4 bits representing ModulationValue - 1.
|
||
There are ( 16 groups * 7 bands ) / 2 = 66 values."
|
||
::= { plcChannelModulationStringEntry 2 }
|
||
|
||
plcTxChannelModulation OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude values for the Tx channel of
|
||
a given remote connection entry.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is an octet representing two modulation values.
|
||
Each modulation is coded on 4 bits.
|
||
There are ( 16 groups * 7 bands ) / 2 = 66 values."
|
||
::= { plcChannelModulationStringEntry 3 }
|
||
|
||
|
||
plcChannelModulationTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcChannelModulationEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains the modulation amplitude
|
||
configuration of all active channels."
|
||
::= { plcTopo 4 }
|
||
|
||
|
||
plcChannelModulationEntry OBJECT-TYPE
|
||
SYNTAX PlcChannelModulationEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains modulation amplitude configuration
|
||
of the channel, referenced by the plcPortChannelIndex,
|
||
of the remote connection referenced by
|
||
plcBasePortIndex."
|
||
INDEX { plcBasePortIndex,
|
||
plcPortChannelIndex,
|
||
plcModBandIndex }
|
||
::= { plcChannelModulationTable 1 }
|
||
|
||
PlcChannelModulationEntry ::= SEQUENCE {
|
||
plcModBandIndex BandValue,
|
||
plcModGroup1 ModulationValue,
|
||
plcModGroup2 ModulationValue,
|
||
plcModGroup3 ModulationValue,
|
||
plcModGroup4 ModulationValue,
|
||
plcModGroup5 ModulationValue,
|
||
plcModGroup6 ModulationValue,
|
||
plcModGroup7 ModulationValue,
|
||
plcModGroup8 ModulationValue,
|
||
plcModGroup9 ModulationValue,
|
||
plcModGroup10 ModulationValue,
|
||
plcModGroup11 ModulationValue,
|
||
plcModGroup12 ModulationValue,
|
||
plcModGroup13 ModulationValue,
|
||
plcModGroup14 ModulationValue,
|
||
plcModGroup15 ModulationValue,
|
||
plcModGroup16 ModulationValue
|
||
}
|
||
|
||
|
||
plcModBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number of which the modulations are defined"
|
||
::= { plcChannelModulationEntry 1 }
|
||
|
||
|
||
plcModGroup1 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the first group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 2 }
|
||
|
||
|
||
plcModGroup2 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the second group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 3 }
|
||
|
||
|
||
plcModGroup3 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the third group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 4 }
|
||
|
||
|
||
plcModGroup4 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the fourth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 5 }
|
||
|
||
|
||
plcModGroup5 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the fifth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 6 }
|
||
|
||
|
||
plcModGroup6 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the sixth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 7 }
|
||
|
||
|
||
plcModGroup7 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the seventh group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 8 }
|
||
|
||
|
||
plcModGroup8 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the eighth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 9 }
|
||
|
||
|
||
plcModGroup9 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the nineth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 10 }
|
||
|
||
|
||
plcModGroup10 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the tenth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 11 }
|
||
|
||
|
||
plcModGroup11 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the eleventh group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 12 }
|
||
|
||
|
||
plcModGroup12 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the twelveth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 13 }
|
||
|
||
|
||
plcModGroup13 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the thirteenth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 14 }
|
||
|
||
|
||
plcModGroup14 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the fourteenth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 15 }
|
||
|
||
|
||
plcModGroup15 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the fifteenth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 16 }
|
||
|
||
|
||
plcModGroup16 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the sixteenth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 17 }
|
||
|
||
|
||
plcChannelModulationInput OBJECT IDENTIFIER
|
||
::= { plcTopo 5 }
|
||
|
||
plcModulationInputAddr OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The MAC address of the MAC layer above
|
||
the plc interface of the remote
|
||
PLC equipment for which the modulation
|
||
value changes are requested."
|
||
::= { plcChannelModulationInput 1 }
|
||
|
||
plcModulationInputChannel OBJECT-TYPE
|
||
SYNTAX PlcChannelType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The channel type of the remote PLC equipment
|
||
for which the modulation value changes
|
||
are requested."
|
||
::= { plcChannelModulationInput 2 }
|
||
|
||
plcModulationInputBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The band number of which the modulation value
|
||
changes are requested."
|
||
::= { plcChannelModulationInput 3 }
|
||
|
||
plcInputModulationGroup1 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
first group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 4 }
|
||
|
||
plcInputModulationGroup2 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
second group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 5 }
|
||
|
||
plcInputModulationGroup3 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
third group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 6 }
|
||
|
||
plcInputModulationGroup4 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
fourth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 7 }
|
||
|
||
plcInputModulationGroup5 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
fifth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 8 }
|
||
|
||
plcInputModulationGroup6 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
sixth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 9 }
|
||
|
||
plcInputModulationGroup7 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
seventh group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 10 }
|
||
|
||
plcInputModulationGroup8 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
eighth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 11 }
|
||
|
||
plcInputModulationGroup9 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
nineth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 12 }
|
||
|
||
plcInputModulationGroup10 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
tenth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 13 }
|
||
|
||
plcInputModulationGroup11 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
eleventh group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 14 }
|
||
|
||
plcInputModulationGroup12 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
twelveth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 15 }
|
||
|
||
plcInputModulationGroup13 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
thirteenth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 16 }
|
||
|
||
plcInputModulationGroup14 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
fourteenth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 17 }
|
||
|
||
plcInputModulationGroup15 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
fifteenth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 18 }
|
||
|
||
plcInputModulationGroup16 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
sixteenth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 19 }
|
||
|
||
|
||
plcModulationInputProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request a modification of all the modulations
|
||
associated to a band and a channel of a remote
|
||
PLC equipment."
|
||
::= { plcChannelModulationInput 20 }
|
||
|
||
plcModulationInputResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested modulation value changes."
|
||
::= { plcChannelModulationInput 21 }
|
||
|
||
plcPortChannelTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcPortChannelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains the list of plc channels"
|
||
::= { plcTopo 6 }
|
||
|
||
plcPortChannelEntry OBJECT-TYPE
|
||
SYNTAX PlcPortChannelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains plc channel information"
|
||
INDEX { plcBasePortIndex, plcPortChannelIndex }
|
||
::= { plcPortChannelTable 1 }
|
||
|
||
PlcPortChannelEntry ::= SEQUENCE {
|
||
plcPortChannelIndex Unsigned32,
|
||
plcPortChannelType PlcChannelType,
|
||
plcPortChannelGain Integer32,
|
||
plcPortChannelBandwidth ChannelBandwidthValue,
|
||
plcPortChannelMaxBandwidth ChannelBandwidthValue,
|
||
plcPortChannelSynchronizationBand BandValue
|
||
}
|
||
|
||
|
||
plcPortChannelIndex OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The channel number belongs to the remote connection
|
||
with plc equipment associated with the
|
||
plcBasePortIndex value.
|
||
Only three channels are expected.
|
||
Index 1 for RX channel
|
||
Index 2 for RXLast channel
|
||
index 3 for TX channel"
|
||
::= { plcPortChannelEntry 1 }
|
||
|
||
|
||
plcPortChannelType OBJECT-TYPE
|
||
SYNTAX PlcChannelType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The channel type."
|
||
::= { plcPortChannelEntry 2 }
|
||
|
||
|
||
plcPortChannelGain OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The gain associated with the channel."
|
||
::= { plcPortChannelEntry 3 }
|
||
|
||
plcPortChannelBandwidth OBJECT-TYPE
|
||
SYNTAX ChannelBandwidthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The bandwidth of the channel in Kbit/s."
|
||
::= { plcPortChannelEntry 4 }
|
||
|
||
--PR01 BEGIN
|
||
plcPortChannelMaxBandwidth OBJECT-TYPE
|
||
SYNTAX ChannelBandwidthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The maximum bandwidth of the channel in Kbit/s."
|
||
::= { plcPortChannelEntry 5 }
|
||
--PR01 END
|
||
|
||
plcPortChannelSynchronizationBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The synchronization band used for this channel."
|
||
::= { plcPortChannelEntry 6 }
|
||
|
||
plcChannelPilotStringTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcChannelPilotStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains the string values representing
|
||
of pilot values of all active channels."
|
||
::= { plcTopo 7 }
|
||
|
||
|
||
plcChannelPilotStringEntry OBJECT-TYPE
|
||
SYNTAX PlcChannelPilotStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains a quick access for pilot values ,
|
||
of the remote connection referenced by
|
||
plcBasePortIndex."
|
||
INDEX { plcBasePortIndex }
|
||
::= { plcChannelPilotStringTable 1 }
|
||
|
||
|
||
PlcChannelPilotStringEntry ::= SEQUENCE {
|
||
plcRxChannelPilots OCTET STRING,
|
||
plcRxLastChannelPilots OCTET STRING,
|
||
plcTxChannelPilots OCTET STRING}
|
||
|
||
|
||
plcRxChannelPilots OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave numbers which support
|
||
the pilot waves for the Rx Channel.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is a pair of octets representing the pilot
|
||
values. There is one pair (pilot1 pilot2) for each
|
||
of the 7 bands."
|
||
::= { plcChannelPilotStringEntry 1 }
|
||
|
||
|
||
plcRxLastChannelPilots OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave numbers which support
|
||
the pilot waves for the Rx Last Channel.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is a pair of octets representing the pilot
|
||
values. There is one pair (pilot1 pilot2) for each
|
||
of the 7 bands."
|
||
::= { plcChannelPilotStringEntry 2 }
|
||
|
||
|
||
plcTxChannelPilots OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave numbers which support
|
||
the pilot waves for the Tx Channel.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is a pair of octets representing the pilot
|
||
values. There is one pair (pilot1 pilot2) for each
|
||
of the 7 bands."
|
||
::= { plcChannelPilotStringEntry 3 }
|
||
|
||
|
||
plcChannelPilotsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcChannelPilotsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This tabel contains pilots configuration
|
||
for each plc channel."
|
||
::= { plcTopo 8 }
|
||
|
||
|
||
plcChannelPilotsEntry OBJECT-TYPE
|
||
SYNTAX PlcChannelPilotsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains the pilots 1 and 2 configuration
|
||
for a channel defined by the
|
||
couple (plcBasePortIndex, plcPortChannelIndex)"
|
||
INDEX { plcBasePortIndex,
|
||
plcPortChannelIndex,
|
||
plcChannelPilotBandIndex }
|
||
::= { plcChannelPilotsTable 1 }
|
||
|
||
PlcChannelPilotsEntry ::= SEQUENCE {
|
||
plcChannelPilotBandIndex BandValue,
|
||
plcChannelPilot1 PilotValue,
|
||
plcChannePilot2 PilotValue
|
||
}
|
||
|
||
|
||
plcChannelPilotBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the pilots are defined."
|
||
::= { plcChannelPilotsEntry 1 }
|
||
|
||
|
||
plcChannelPilot1 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave number which supports
|
||
the first pilot wave for the channel
|
||
associated with this entry."
|
||
::= { plcChannelPilotsEntry 2 }
|
||
|
||
|
||
plcChannePilot2 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave number which supports
|
||
the second pilot wave for the channel
|
||
associated with this entry."
|
||
::= { plcChannelPilotsEntry 3 }
|
||
|
||
|
||
plcChannelPilotsInput OBJECT IDENTIFIER
|
||
::= { plcTopo 9 }
|
||
|
||
plcPilotsInputAddr OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The MAC address of the MAC layer above
|
||
the plc interface of the remote
|
||
PLC equipment for which the pilot
|
||
value changes are requested."
|
||
::= { plcChannelPilotsInput 1 }
|
||
|
||
plcPilotsInputChannel OBJECT-TYPE
|
||
SYNTAX PlcChannelType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The channel type of the remote PLC equipment
|
||
for which the pilot value changes
|
||
are requested."
|
||
::= { plcChannelPilotsInput 2 }
|
||
|
||
plcPilotsInputBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The band number of which the pilots value
|
||
changes are requested."
|
||
::= { plcChannelPilotsInput 3 }
|
||
|
||
|
||
plcInputChannelPilot1 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave number which supports
|
||
the first pilot wave for the considered band and
|
||
channel input values."
|
||
::= { plcChannelPilotsInput 4 }
|
||
|
||
plcInputChannelPilot2 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave number which supports
|
||
the second pilot wave for the considered band and
|
||
channel input values."
|
||
::= { plcChannelPilotsInput 5 }
|
||
|
||
plcPilotsInputProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request a modification of the first and second pilot
|
||
associated to a band and a channel of a remote
|
||
PLC equipment."
|
||
::= { plcChannelPilotsInput 6 }
|
||
|
||
plcPilotsInputResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested pilot values changes."
|
||
::= { plcChannelPilotsInput 7 }
|
||
|
||
plcNodeNotches OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The values of the notches for all the node bands.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is an octet representing the 8 notches of
|
||
each group. There is one value for each 7 * 16 bands."
|
||
::= { plcNodeConfiguration 1 }
|
||
|
||
plcNodeNotchesTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcNodeNotchesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains Notches configuration
|
||
for the SPC200 chip."
|
||
::= { plcNodeConfiguration 2 }
|
||
|
||
plcNodeNotchesEntry OBJECT-TYPE
|
||
SYNTAX PlcNodeNotchesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains Notches configuration for a group.
|
||
The group is defined by the couple
|
||
(plcNodeNotchesGroupIndex, plcNodeNotchesBandIndex)."
|
||
INDEX { plcNodeNotchesBandIndex, plcNodeNotchesGroupIndex }
|
||
::= { plcNodeNotchesTable 1 }
|
||
|
||
PlcNodeNotchesEntry ::= SEQUENCE {
|
||
plcNodeNotchesBandIndex BandValue,
|
||
plcNodeNotchesGroupIndex GroupValue,
|
||
plcNodeNotchesCarrier1 TruthValue,
|
||
plcNodeNotchesCarrier2 TruthValue,
|
||
plcNodeNotchesCarrier3 TruthValue,
|
||
plcNodeNotchesCarrier4 TruthValue,
|
||
plcNodeNotchesCarrier5 TruthValue,
|
||
plcNodeNotchesCarrier6 TruthValue,
|
||
plcNodeNotchesCarrier7 TruthValue,
|
||
plcNodeNotchesCarrier8 TruthValue
|
||
}
|
||
|
||
|
||
plcNodeNotchesBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the notches are defined."
|
||
::= { plcNodeNotchesEntry 1 }
|
||
|
||
|
||
plcNodeNotchesGroupIndex OBJECT-TYPE
|
||
SYNTAX GroupValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the notches are defined."
|
||
::= { plcNodeNotchesEntry 2 }
|
||
|
||
|
||
plcNodeNotchesCarrier1 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the first carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 3 }
|
||
|
||
|
||
plcNodeNotchesCarrier2 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the second carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 4 }
|
||
|
||
|
||
plcNodeNotchesCarrier3 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the third carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 5 }
|
||
|
||
|
||
plcNodeNotchesCarrier4 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the fourth carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 6 }
|
||
|
||
|
||
plcNodeNotchesCarrier5 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the fifth carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 7 }
|
||
|
||
|
||
plcNodeNotchesCarrier6 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the sixth carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 8 }
|
||
|
||
|
||
plcNodeNotchesCarrier7 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the seventh carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 9 }
|
||
|
||
|
||
plcNodeNotchesCarrier8 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the eighth carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 10 }
|
||
|
||
plcNodeNotchesInput OBJECT IDENTIFIER
|
||
::= { plcNodeConfiguration 3 }
|
||
|
||
plcNodeNotchesInputBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the notches value
|
||
changes are requested."
|
||
::= { plcNodeNotchesInput 1 }
|
||
|
||
|
||
plcNodeNotchesInputGroup OBJECT-TYPE
|
||
SYNTAX GroupValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the notches value
|
||
changes are requested."
|
||
::= { plcNodeNotchesInput 2 }
|
||
|
||
plcNodeNotchesInputCarrier1 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The first carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 3 }
|
||
|
||
plcNodeNotchesInputCarrier2 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The second carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 4 }
|
||
|
||
plcNodeNotchesInputCarrier3 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The third carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 5 }
|
||
|
||
plcNodeNotchesInputCarrier4 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The fourth carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 6 }
|
||
|
||
plcNodeNotchesInputCarrier5 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The eighth carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 7 }
|
||
|
||
plcNodeNotchesInputCarrier6 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The eighth carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 8 }
|
||
|
||
plcNodeNotchesInputCarrier7 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The seventh carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 9 }
|
||
|
||
plcNodeNotchesInputCarrier8 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The eighth carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 10 }
|
||
|
||
plcNodeNotchesInputProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request a modification of the carrier notches
|
||
associated to the considered group and
|
||
band."
|
||
::= { plcNodeNotchesInput 11 }
|
||
|
||
plcNodeNotchesInputResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested node carrier notches value changes."
|
||
::= { plcNodeNotchesInput 12 }
|
||
|
||
|
||
plcNodePilots OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The values of the pilot for all the node bands.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is a pair of octets representing the pilot
|
||
values. There is one pair (pilot1 pilot2) for each
|
||
of the 7 bands."
|
||
::= { plcNodeConfiguration 4 }
|
||
|
||
plcNodePilotsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcNodePilotsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains pilot values
|
||
used by default on all channels."
|
||
::= { plcNodeConfiguration 5 }
|
||
|
||
plcNodePilotsEntry OBJECT-TYPE
|
||
SYNTAX PlcNodePilotsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains pilot values
|
||
used by default on a band.
|
||
The band is defined by the index
|
||
plcNodePilotsBandIndex."
|
||
INDEX { plcNodePilotsBandIndex }
|
||
::= { plcNodePilotsTable 1 }
|
||
|
||
PlcNodePilotsEntry ::= SEQUENCE {
|
||
plcNodePilotsBandIndex BandValue,
|
||
plcNodePilot1 PilotValue,
|
||
plcNodePilot2 PilotValue
|
||
}
|
||
|
||
|
||
plcNodePilotsBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the pilot values are defined."
|
||
::= { plcNodePilotsEntry 1 }
|
||
|
||
|
||
plcNodePilot1 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The default carrier wave number
|
||
which supports the first pilot wave."
|
||
::= { plcNodePilotsEntry 2 }
|
||
|
||
|
||
plcNodePilot2 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The default carrier wave number
|
||
which supports the second pilot wave."
|
||
::= { plcNodePilotsEntry 3 }
|
||
|
||
|
||
plcNodePilotsInput OBJECT IDENTIFIER
|
||
::= { plcNodeConfiguration 6 }
|
||
|
||
plcNodePilotsInputBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the pilot values
|
||
changes are requested."
|
||
::= { plcNodePilotsInput 1 }
|
||
|
||
|
||
plcInputNodePilot1 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The default carrier wave number
|
||
which supports the first pilot wave of
|
||
the considered band."
|
||
::= { plcNodePilotsInput 2 }
|
||
|
||
plcInputNodePilot2 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The default carrier wave number
|
||
which supports the second pilot wave of
|
||
the considered band."
|
||
::= { plcNodePilotsInput 3 }
|
||
|
||
|
||
plcNodePilotsInputProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request a modification of the pilot values
|
||
associated to the considered band."
|
||
::= { plcNodePilotsInput 4 }
|
||
|
||
plcNodePilotsInputResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested node pilot values changes."
|
||
::= { plcNodePilotsInput 5 }
|
||
|
||
plcNodeAdaptsStringTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcNodeAdaptsStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains string values for a
|
||
quick access to the adapt configurations
|
||
of all the carriers."
|
||
::= { plcNodeConfiguration 7 }
|
||
|
||
|
||
plcNodeAdaptsStringEntry OBJECT-TYPE
|
||
SYNTAX PlcNodeAdaptsStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains string values for a quick access to
|
||
the adapt configuration
|
||
of each carrier of a band."
|
||
INDEX { plcBasePortIndex , plcNodeAdaptsStringBandIndex }
|
||
::= { plcNodeAdaptsStringTable 1 }
|
||
|
||
PlcNodeAdaptsStringEntry ::= SEQUENCE {
|
||
plcNodeAdaptsStringBandIndex BandValue,
|
||
plcNodeAdaptsStringBand OCTET STRING }
|
||
|
||
plcNodeAdaptsStringBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the adapt values are defined."
|
||
::= { plcNodeAdaptsStringEntry 1 }
|
||
|
||
plcNodeAdaptsStringBand OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt values of the 128 carriers of a band.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is two octets representing one adapt carrier
|
||
level.
|
||
There are ( 16 groups * 8 carriers) = 128 values."
|
||
::= { plcNodeAdaptsStringEntry 2 }
|
||
|
||
plcNodeAdaptsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcNodeAdaptsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains adapt level configuration
|
||
for each carrier of the node."
|
||
::= { plcNodeConfiguration 8 }
|
||
|
||
plcNodeAdaptsEntry OBJECT-TYPE
|
||
SYNTAX PlcNodeAdaptsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains adapt level values
|
||
for a group of carriers.
|
||
The group is defined by the couple
|
||
(plcNodeAdaptsBandIndex,plcNodeAdaptsGroupIndex)."
|
||
INDEX { plcNodeAdaptsBandIndex,plcNodeAdaptsGroupIndex }
|
||
::= { plcNodeAdaptsTable 1 }
|
||
|
||
PlcNodeAdaptsEntry ::= SEQUENCE {
|
||
plcNodeAdaptsBandIndex BandValue,
|
||
plcNodeAdaptsGroupIndex GroupValue,
|
||
plcNodeAdaptsCarrier1 AdaptValue,
|
||
plcNodeAdaptsCarrier2 AdaptValue,
|
||
plcNodeAdaptsCarrier3 AdaptValue,
|
||
plcNodeAdaptsCarrier4 AdaptValue,
|
||
plcNodeAdaptsCarrier5 AdaptValue,
|
||
plcNodeAdaptsCarrier6 AdaptValue,
|
||
plcNodeAdaptsCarrier7 AdaptValue,
|
||
plcNodeAdaptsCarrier8 AdaptValue
|
||
}
|
||
|
||
|
||
plcNodeAdaptsBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the adapt values are defined."
|
||
::= { plcNodeAdaptsEntry 1 }
|
||
|
||
plcNodeAdaptsGroupIndex OBJECT-TYPE
|
||
SYNTAX GroupValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the adapt values are defined."
|
||
::= { plcNodeAdaptsEntry 2 }
|
||
|
||
plcNodeAdaptsCarrier1 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the first carrier of the group."
|
||
::= { plcNodeAdaptsEntry 3 }
|
||
|
||
plcNodeAdaptsCarrier2 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the second carrier of the group."
|
||
::= { plcNodeAdaptsEntry 4 }
|
||
|
||
plcNodeAdaptsCarrier3 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the third carrier of the group."
|
||
::= { plcNodeAdaptsEntry 5 }
|
||
|
||
plcNodeAdaptsCarrier4 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the fourth carrier of the group."
|
||
::= { plcNodeAdaptsEntry 6 }
|
||
|
||
plcNodeAdaptsCarrier5 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the fifth carrier of the group."
|
||
::= { plcNodeAdaptsEntry 7 }
|
||
|
||
plcNodeAdaptsCarrier6 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the sixth carrier of the group."
|
||
::= { plcNodeAdaptsEntry 8 }
|
||
|
||
plcNodeAdaptsCarrier7 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the seventh carrier of the group."
|
||
::= { plcNodeAdaptsEntry 9 }
|
||
|
||
plcNodeAdaptsCarrier8 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the eighth carrier of the group."
|
||
::= { plcNodeAdaptsEntry 10 }
|
||
|
||
plcNodeAdaptsInput OBJECT IDENTIFIER
|
||
::= { plcNodeConfiguration 9 }
|
||
|
||
plcNodeAdaptsInputBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the adapt level value
|
||
changes are requested."
|
||
::= { plcNodeAdaptsInput 1 }
|
||
|
||
|
||
plcNodeAdaptsInputGroup OBJECT-TYPE
|
||
SYNTAX GroupValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the adapt level value
|
||
changes are requested."
|
||
::= { plcNodeAdaptsInput 2 }
|
||
|
||
plcNodeAdaptsInputCarrier1 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the first carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 3 }
|
||
|
||
plcNodeAdaptsInputCarrier2 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the second carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 4 }
|
||
|
||
plcNodeAdaptsInputCarrier3 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the third carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 5 }
|
||
|
||
plcNodeAdaptsInputCarrier4 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the fourth carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 6 }
|
||
|
||
plcNodeAdaptsInputCarrier5 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the fifth carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 7 }
|
||
|
||
plcNodeAdaptsInputCarrier6 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the sixth carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 8 }
|
||
|
||
plcNodeAdaptsInputCarrier7 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the seventh carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 9 }
|
||
|
||
plcNodeAdaptsInputCarrier8 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the eighth carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 10 }
|
||
|
||
plcNodeAdaptsInputProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request a modification of the carrier
|
||
adapt level associated to the considered group and
|
||
band."
|
||
::= { plcNodeAdaptsInput 11 }
|
||
|
||
plcNodeAdaptsInputResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested node adapt level
|
||
value changes."
|
||
::= { plcNodeAdaptsInput 12 }
|
||
|
||
plcNodeNetConfigTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcNodeNetConfigEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains ip and mac
|
||
addresses of the node."
|
||
::= { plcNodeConfiguration 10 }
|
||
|
||
plcNodeNetConfigEntry OBJECT-TYPE
|
||
SYNTAX PlcNodeNetConfigEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains ip and mac address
|
||
used by an interface."
|
||
INDEX { ifIndex }
|
||
::= { plcNodeNetConfigTable 1 }
|
||
|
||
PlcNodeNetConfigEntry ::= SEQUENCE {
|
||
plcNodeIpAddr IpAddress,
|
||
plcNodeNetMask IpAddress,
|
||
plcNodeMacAddr MacAddress,
|
||
plcNodeGateway IpAddress
|
||
}
|
||
|
||
|
||
plcNodeIpAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The IP address of the IP layer above the interface."
|
||
::= { plcNodeNetConfigEntry 1 }
|
||
|
||
|
||
plcNodeNetMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The IP Subnet mask of the IP layer above the interface."
|
||
::= { plcNodeNetConfigEntry 2 }
|
||
|
||
|
||
plcNodeMacAddr OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The MAC address of the MAC layer above the interface."
|
||
::= { plcNodeNetConfigEntry 3 }
|
||
|
||
plcNodeGateway OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The Gateway address of the IP layer above the interface."
|
||
::= { plcNodeNetConfigEntry 4 }
|
||
|
||
plcNodeActions OBJECT IDENTIFIER
|
||
::= { plcNodeConfiguration 11 }
|
||
|
||
plcNodeActionsCommit OBJECT IDENTIFIER
|
||
::= { plcNodeActions 1 }
|
||
|
||
plcNodeActionsCommitProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request the commit of the configuration
|
||
changes into the flash memory"
|
||
::= { plcNodeActionsCommit 1 }
|
||
|
||
plcNodeActionsCommitResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested flash commit operation."
|
||
::= { plcNodeActionsCommit 2 }
|
||
|
||
plcNodeActionsReset OBJECT IDENTIFIER
|
||
::= { plcNodeActions 2 }
|
||
|
||
plcNodeActionsResetProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request the reset of the node.
|
||
This operation will terminate the communication
|
||
between the manager and the node"
|
||
::= { plcNodeActionsReset 1 }
|
||
|
||
plcNodeActionsCarrier OBJECT IDENTIFIER
|
||
::= { plcNodeActions 3 }
|
||
|
||
plcNodeActionsCarrierFlatProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request the equipment to flat the signal"
|
||
::= { plcNodeActionsCarrier 1 }
|
||
|
||
|
||
plcBssId OBJECT IDENTIFIER
|
||
::= { plcObjects 6 }
|
||
|
||
plcMasterBssId OBJECT-TYPE
|
||
SYNTAX INTEGER(0..99)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The value of the master Bss Id"
|
||
::= { plcBssId 1 }
|
||
|
||
plcSlaveBssId OBJECT-TYPE
|
||
SYNTAX INTEGER(0..99)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The value of the slave Bss Id"
|
||
::= { plcBssId 2 }
|
||
|
||
plcSpy OBJECT IDENTIFIER
|
||
::= { plcObjects 7 }
|
||
|
||
plcSpyIsDynamic OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to set the spy dynamic mode"
|
||
::= { plcSpy 1 }
|
||
|
||
plcStaticSpySynchBandNb OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The synchronization band number used for static spy mode"
|
||
::= { plcSpy 2 }
|
||
|
||
|
||
-- software upload
|
||
softwareMgnt OBJECT IDENTIFIER
|
||
::= { plc 3 }
|
||
|
||
-- current version
|
||
currentSoftwareVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The name of the current software release."
|
||
::= { softwareMgnt 1 }
|
||
|
||
currentSoftwareBoardVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The name of the current software board release."
|
||
::= { softwareMgnt 2 }
|
||
|
||
currentSoftwareAFEVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The name of the current software Analog Front End release."
|
||
::= { softwareMgnt 3 }
|
||
|
||
-- table of software
|
||
softwareTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SoftwareEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains the current and reserve
|
||
softwares of the node."
|
||
::= { softwareMgnt 4 }
|
||
|
||
softwareEntry OBJECT-TYPE
|
||
SYNTAX SoftwareEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains software information."
|
||
INDEX { softwareIndex }
|
||
::= { softwareTable 1 }
|
||
|
||
SoftwareEntry ::= SEQUENCE {
|
||
softwareIndex SoftwareIndex,
|
||
softwareVersion DisplayString
|
||
}
|
||
|
||
softwareIndex OBJECT-TYPE
|
||
SYNTAX SoftwareIndex
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The index number of the software."
|
||
::= { softwareEntry 1 }
|
||
|
||
softwareVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The name of the software release."
|
||
::= { softwareEntry 2 }
|
||
|
||
-- upload software action
|
||
softwareUpload OBJECT IDENTIFIER
|
||
::= { softwareMgnt 5 }
|
||
|
||
softwareUploadTFTPServerIP OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The IP address of the TFTP serveur"
|
||
::= { softwareUpload 1 }
|
||
|
||
|
||
softwareUploadLogin OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The user login on the TFTP server"
|
||
::= { softwareUpload 2 }
|
||
|
||
softwareUploadPassword OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The user password on the TFTP server.
|
||
Warning: This field is displayed using 6 * characters"
|
||
::= { softwareUpload 3 }
|
||
|
||
softwareUploadFileName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The software file name to upload"
|
||
::= { softwareUpload 4 }
|
||
|
||
softwareUploadProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request the uploading to start"
|
||
::= { softwareUpload 5 }
|
||
|
||
softwareUploadResult OBJECT-TYPE
|
||
SYNTAX SoftwareActionResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested uploading"
|
||
::= { softwareUpload 6 }
|
||
|
||
softwareUploadTFTPServerPort OBJECT-TYPE -- PR01
|
||
SYNTAX Integer32 ( 0..65535 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The service port of the TFTP server"
|
||
::= { softwareUpload 7 }
|
||
|
||
|
||
-- software action
|
||
softwareAction OBJECT IDENTIFIER
|
||
::= { softwareMgnt 6 }
|
||
|
||
softwareActionIndex OBJECT-TYPE
|
||
SYNTAX SoftwareIndex
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The index of the reserve software"
|
||
::= { softwareAction 1 }
|
||
|
||
softwareActionType OBJECT-TYPE
|
||
SYNTAX SoftwareActionType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Type of the software action software:
|
||
switch, remove "
|
||
::= { softwareAction 2 }
|
||
|
||
softwareActionProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request the switch between the current
|
||
and the reserver software to start"
|
||
::= { softwareAction 3 }
|
||
|
||
softwareActionResult OBJECT-TYPE
|
||
SYNTAX SoftwareActionResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested action"
|
||
::= { softwareAction 4 }
|
||
|
||
|
||
-- compliance
|
||
plcConformance OBJECT IDENTIFIER
|
||
::= { plc 4 }
|
||
|
||
plcCompliances OBJECT IDENTIFIER
|
||
::= { plcConformance 1 }
|
||
|
||
plcGroups OBJECT IDENTIFIER
|
||
::= { plcConformance 2 }
|
||
|
||
plcCompliance MODULE-COMPLIANCE
|
||
STATUS current
|
||
DESCRIPTION "The compliance statement for SPC200 chip."
|
||
|
||
MODULE
|
||
MANDATORY-GROUPS { nodeGroup, topologyGroup }
|
||
GROUP statisticGroup
|
||
DESCRIPTION "This group is mandatory for
|
||
channel performances analysis"
|
||
::= { plcCompliances 1 }
|
||
|
||
nodeGroup OBJECT-GROUP
|
||
OBJECTS { plcNodeNotches, plcMode,
|
||
plcNodeNotchesCarrier1, plcNodeNotchesCarrier2,
|
||
plcNodeNotchesCarrier3, plcNodeNotchesCarrier4,
|
||
plcNodeNotchesCarrier5, plcNodeNotchesCarrier6,
|
||
plcNodeNotchesCarrier7, plcNodeNotchesCarrier8,
|
||
plcNodePilots, plcNodePilot1, plcNodePilot2,
|
||
plcNodeAdaptsStringBand, plcNodeAdaptsCarrier1,
|
||
plcNodeAdaptsCarrier2, plcNodeAdaptsCarrier3,
|
||
plcNodeAdaptsCarrier4, plcNodeAdaptsCarrier5,
|
||
plcNodeAdaptsCarrier6, plcNodeAdaptsCarrier7,
|
||
plcNodeAdaptsCarrier8,
|
||
plcNodeIpAddr, plcNodeNetMask, plcNodeMacAddr,
|
||
plcNodeGateway, plcMasterBssId, plcSlaveBssId,
|
||
plcSpyIsDynamic, plcStaticSpySynchBandNb }
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects providing
|
||
node configuration information."
|
||
::= { plcGroups 1 }
|
||
|
||
inputNodeGroup OBJECT-GROUP
|
||
OBJECTS { plcNodeNotchesInputBand, plcNodeNotchesInputGroup,
|
||
plcNodeNotchesInputCarrier1, plcNodeNotchesInputCarrier2,
|
||
plcNodeNotchesInputCarrier3, plcNodeNotchesInputCarrier4,
|
||
plcNodeNotchesInputCarrier5, plcNodeNotchesInputCarrier6,
|
||
plcNodeNotchesInputCarrier7, plcNodeNotchesInputCarrier8,
|
||
plcNodeNotchesInputProceed, plcNodeNotchesInputResult,
|
||
plcNodePilotsInputBand,
|
||
plcInputNodePilot1, plcInputNodePilot2,
|
||
plcNodePilotsInputProceed,plcNodePilotsInputResult,
|
||
plcNodeAdaptsInputBand, plcNodeAdaptsInputGroup,
|
||
plcNodeAdaptsInputCarrier1, plcNodeAdaptsInputCarrier2,
|
||
plcNodeAdaptsInputCarrier3, plcNodeAdaptsInputCarrier4,
|
||
plcNodeAdaptsInputCarrier5, plcNodeAdaptsInputCarrier6,
|
||
plcNodeAdaptsInputCarrier7, plcNodeAdaptsInputCarrier8,
|
||
plcNodeAdaptsInputProceed, plcNodeAdaptsInputResult,
|
||
plcNodeActionsCommitProceed, plcNodeActionsCommitResult,
|
||
plcNodeActionsResetProceed, plcNodeActionsCarrierFlatProceed}
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects used to request
|
||
node configuration information changes."
|
||
::= { plcGroups 2 }
|
||
|
||
topologyGroup OBJECT-GROUP
|
||
OBJECTS { plcBasePortAddress, plcBasePortChannelEstimation,
|
||
plcBasePortAttenuation ,
|
||
plcChannePilot2, plcChannelPilot1,
|
||
plcRxChannelPilots,
|
||
plcRxLastChannelPilots,
|
||
plcTxChannelPilots,
|
||
plcRxChannelModulation,
|
||
plcRxLastChannelModulation,
|
||
plcTxChannelModulation,
|
||
plcModGroup1, plcModGroup10, plcModGroup11,
|
||
plcModGroup12, plcModGroup13, plcModGroup14,
|
||
plcModGroup15, plcModGroup16, plcModGroup2,
|
||
plcModGroup3, plcModGroup4, plcModGroup5,
|
||
plcModGroup6, plcModGroup7, plcModGroup8,
|
||
plcModGroup9,
|
||
plcPortChannelGain,
|
||
plcPortChannelBandwidth,
|
||
plcPortChannelMaxBandwidth,
|
||
plcPortChannelSynchronizationBand,
|
||
plcPortChannelType, plcTopoChanges }
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects providing
|
||
topology configuration."
|
||
::= { plcGroups 3 }
|
||
|
||
inputTopologyGroup OBJECT-GROUP
|
||
OBJECTS { plcModulationInputAddr, plcModulationInputChannel, plcModulationInputBand,
|
||
plcInputModulationGroup1, plcInputModulationGroup2,
|
||
plcInputModulationGroup3, plcInputModulationGroup4,
|
||
plcInputModulationGroup5, plcInputModulationGroup6,
|
||
plcInputModulationGroup7, plcInputModulationGroup8,
|
||
plcInputModulationGroup9, plcInputModulationGroup10,
|
||
plcInputModulationGroup11, plcInputModulationGroup12,
|
||
plcInputModulationGroup13, plcInputModulationGroup14,
|
||
plcInputModulationGroup15, plcInputModulationGroup16,
|
||
plcModulationInputProceed, plcModulationInputResult,
|
||
plcPilotsInputAddr, plcPilotsInputChannel, plcPilotsInputBand,
|
||
plcInputChannelPilot1, plcInputChannelPilot2,
|
||
plcPilotsInputProceed, plcPilotsInputResult }
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects used to request
|
||
topology configuration changes."
|
||
::= { plcGroups 4 }
|
||
|
||
statisticGroup OBJECT-GROUP
|
||
OBJECTS { --PR01 BEGIN
|
||
-- ipBridgedPackets, ipInBridgedPkts,
|
||
-- ipInErrorPackets, ipInErrorPkts, ipInPackets,
|
||
-- ipInPkts, ipOutErrorPackets, ipOutErrorPkts,
|
||
-- ipOutPackets, ipOutPkts, macInErrorPkts,
|
||
-- macInPkts, macOutErrorPkts, macOutPackets,
|
||
-- plcpInErrorPkts, plcpInPkts, plcpOutErrorPkts,
|
||
-- plcpOutPkts,
|
||
--PR01 END
|
||
portStats2AvgBandAtt, portStats2AvgBandSNR, --PR01
|
||
-- portStats2Ber,
|
||
portStats2Noise, portStats2Signal,
|
||
-- portStatsBer,
|
||
portStatsNoise, portStatsSignal,
|
||
portStats3AvgAtt, portStats3AvgSNR ,
|
||
bootstatsBoot, bootstatsManualReset, bootstatsFailureReset
|
||
} --PR01
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects providing
|
||
statistic data on node and plc link performances."
|
||
::= { plcGroups 5 }
|
||
|
||
softwareGroup OBJECT-GROUP
|
||
OBJECTS { currentSoftwareVersion, currentSoftwareBoardVersion,
|
||
currentSoftwareAFEVersion, softwareVersion,
|
||
softwareUploadTFTPServerIP, softwareUploadLogin,
|
||
softwareUploadPassword, softwareUploadFileName,
|
||
softwareUploadProceed, softwareUploadResult,
|
||
softwareUploadTFTPServerPort, --PR01
|
||
softwareActionIndex, softwareActionType,
|
||
softwareActionProceed, softwareActionResult }
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects providing
|
||
software management"
|
||
::= { plcGroups 6 }
|
||
|
||
--PR01 BEGIN
|
||
analyserGroup OBJECT-GROUP
|
||
OBJECTS { plcSNAnalyserAGC, plcSNAnalyserEnable,
|
||
plcSNAnalyserMinSignal, plcSNAnalyserMaxSignal,
|
||
plcSNAnalyserAvgSignal, plcSNAnalyserLastSignal,
|
||
plcSNAnalyserFFTDiv,
|
||
plcAGCAnalyserEnable,
|
||
plcAGCAnalyserSamplesPart1, plcAGCAnalyserSamplesPart2 }
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects providing
|
||
spectrum analyser data"
|
||
::= { plcGroups 7 }
|
||
--PR01 END
|
||
|
||
agentCapabilities AGENT-CAPABILITIES
|
||
PRODUCT-RELEASE "Product-Release"
|
||
STATUS current
|
||
DESCRIPTION "The SPC200 chip SNMP agent capabilities"
|
||
|
||
SUPPORTS SPC200
|
||
INCLUDES { nodeGroup, inputNodeGroup,
|
||
topologyGroup, inputTopologyGroup,
|
||
statisticGroup, softwareGroup,
|
||
analyserGroup } --PR01
|
||
|
||
--OK SUPPORTS IF-MIB
|
||
--OK INCLUDES { ifGeneralInformationGroup, ifHCPacketGroup }
|
||
--OK VARIATION ifAdminStatus
|
||
--OK ACCESS read-only
|
||
--OK DESCRIPTION "Forbid the update of the administrative status"
|
||
--OK VARIATION ifLinkUpDownTrapEnable
|
||
--OK ACCESS not-implemented
|
||
--OK DESCRIPTION "No trap supported"
|
||
--KO VARIATION ifAlias
|
||
--KO ACCESS not-implemented
|
||
--KO DESCRIPTION "The non volatile alias name
|
||
--KO cannot be saved on the SPC200 chip"
|
||
--KO VARIATION ifMtu
|
||
--KO ACCESS not-implemented
|
||
--KO DESCRIPTION "Information not available on SPC200 chip"
|
||
|
||
SUPPORTS MAU-MIB
|
||
INCLUDES { mauIfGrpBasic }
|
||
VARIATION ifMauIndex
|
||
DESCRIPTION "Only one MAU. So the value is always 1"
|
||
VARIATION ifMauMediaAvailable
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ifMauMediaAvailableStateExits
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ifMauJabberState
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ifMauJabberingStateEnters
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
|
||
SUPPORTS IP-MIB
|
||
INCLUDES { ipGroup }
|
||
VARIATION ipForwarding
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipDefaultTTL
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipInHdrErrors
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipInAddrErrors
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipForwDatagrams
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipInUnknownProtos
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipInDiscards
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipInDelivers
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipOutDiscards
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipOutNoRoutes
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipReasmTimeout
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipReasmReqds
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipReasmOKs
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipReasmFails
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipFragOKs
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipFragFails
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipFragCreates
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipAdEntBcastAddr
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipAdEntReasmMaxSize
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipRoutingDiscards
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
|
||
SUPPORTS SNMPv2-MIB
|
||
INCLUDES { systemGroup }
|
||
|
||
--OK SUPPORTS BRIDGE-MIB
|
||
--OK INCLUDES { dot1dBase }
|
||
--KO VARIATION dot1dBasePortDelayExceededDiscards
|
||
--KO ACCESS not-implemented
|
||
--KO DESCRIPTION "Information not available on SPC200 chip"
|
||
--KO VARIATION dot1dBasePortMtuExceededDiscards
|
||
--KO ACCESS not-implemented
|
||
--KO DESCRIPTION "Information not available on SPC200 chip"
|
||
|
||
::= { plcConformance 3 }
|
||
|
||
|
||
-- ifTableExt data
|
||
|
||
--ifTableExt OBJECT-TYPE
|
||
-- SYNTAX SEQUENCE OF IfEntryExt
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION
|
||
-- "A list of interface entries. The number of entries is
|
||
-- given by the value of ifNumber. This Table is an Ext of the
|
||
-- standard ifTable located in the IF-MIB."
|
||
-- ::= { spc200MIB 2 }
|
||
|
||
|
||
--ifEntryExt OBJECT-TYPE
|
||
-- SYNTAX IfEntryExt
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION
|
||
-- "An entry containing management information applicable to a
|
||
-- particular interface. These entries are indexed using the ifIndex
|
||
-- of the standard IF-MIB."
|
||
-- INDEX { ifIndex }
|
||
-- ::= { ifTableExt 1 }
|
||
|
||
|
||
--IfEntryExt ::= SEQUENCE {
|
||
-- ifDefaultSpeed Gauge32,
|
||
-- ifSpeedAutoNegAdminStatus INTEGER }
|
||
|
||
|
||
--ifDefaultSpeed OBJECT-TYPE
|
||
-- SYNTAX Gauge32
|
||
-- MAX-ACCESS read-write
|
||
-- STATUS current
|
||
-- DESCRIPTION
|
||
-- "This field is used to set the speed for a given interface.
|
||
-- It contains a default value which will be copied into ifSpeed if
|
||
-- the ifSpeedAutoNegAdminStatus is disabled"
|
||
-- ::= { ifEntryExt 1 }
|
||
|
||
|
||
--ifSpeedAutoNegAdminStatus OBJECT-TYPE
|
||
-- SYNTAX INTEGER {
|
||
-- enabled(1),
|
||
-- disabled(2) }
|
||
-- MAX-ACCESS read-write
|
||
-- STATUS current
|
||
-- DESCRIPTION
|
||
-- "This field is used to enable/disable the speed auto negotiation
|
||
-- process for a given interface. If the status is disabled, the user
|
||
-- can set the speed by setting ifDefaultSpeed.
|
||
-- When the speed auto negotiation status is enabled, the hardware
|
||
-- select a speed and set it in ifSpeed. When the speed auto negotiation
|
||
-- status is disabled, the content of ifDefaultSpeed is copied into
|
||
-- ifSpeed."
|
||
-- ::= { ifEntryExt 2 }
|
||
|
||
|
||
--ifGroupExt OBJECT-GROUP
|
||
-- OBJECTS {
|
||
-- ifDefaultSpeed,
|
||
-- ifSpeedAutoNegAdminStatus }
|
||
-- STATUS current
|
||
-- DESCRIPTION
|
||
-- "The fields needed by the SPiDCOM functionalities"
|
||
|
||
-- ::= { ifTableExt 2 }
|
||
|
||
|
||
-- ipExt data , for DHCP mode
|
||
|
||
ipExt OBJECT-IDENTITY
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Extended ip needed for SPiDCOM functionalities"
|
||
::= { spc200MIB 4 }
|
||
|
||
ipDynamic OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True if Ip address is set dynamically"
|
||
::= { ipExt 1 }
|
||
|
||
ipExtGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
ipDynamic
|
||
}
|
||
STATUS current
|
||
DESCRIPTION "The fields needed by the SPiDCOM functionalities"
|
||
::= { ipExt 2 }
|
||
|
||
END
|