Graham McIntire 5eb1acf9d4 feat(insights): device-overheating recommendation
Operators frequently misdiagnose thermal throttling as RF problems
and waste truck rolls. This rule reads the hottest temperature
sensor per device and, when the device is linked to a Preseem AP
with degraded QoE, makes the thermal-correlation explicit so the
fix is ventilation/shading rather than antenna alignment.

- Towerops.Recommendations.Rules.DeviceOverheating — single query
  pulls the hottest temperature sensor per device above 65 °C; one
  insight per device. Critical at 75 °C+. Includes the linked
  Preseem qoe_score in metadata when present.
- Insight.@valid_types extended with device_overheating.
- LLM prompt hint tells the model to recommend ventilation/fan/
  shading inspection BEFORE any RF action when QoE is also low.
- UI: red card with sensor name, temperature, linked QoE score,
  and an "Above manufacturer spec" badge for >=75 °C.

Wired into RecommendationsRunWorker. 8 new tests.
2026-05-09 17:40:22 -05:00
..
antennas feat: 198 real vendor .msi antenna patterns + Leaflet auto-load 2026-05-06 15:09:29 -05:00
gettext fix: nav overflow on small screens and fix bad gettext translations 2026-03-11 14:00:31 -05:00
mibs mib update from librenms 2026-01-28 13:38:31 -06:00
profiles feat: ePMP firmware extraction + ePMP3000 NetSNMP-quirk detection 2026-05-09 08:34:23 -05:00
proto chore: migrate agent repo references from GitHub to Codeberg 2026-05-07 07:44:48 -05:00
repo feat(insights): AP frequency-change recommendation rule 2026-05-09 16:56:19 -05:00
static feat(insights): device-overheating recommendation 2026-05-09 17:40:22 -05:00