- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
2528 lines
82 KiB
Text
2528 lines
82 KiB
Text
WebGraph-Thermo-Hygro-Barometer-MIB DEFINITIONS ::= BEGIN
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.30
|
||
----------------------------------------------------------------
|
||
-- 14.12.2009 RSS Feed
|
||
--
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.29
|
||
----------------------------------------------------------------
|
||
-- 02.06.2008 Correction wtWebGraphThermBaroHTTP
|
||
-- Correction wtWebGraphThermoBaroDiag
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.28
|
||
----------------------------------------------------------------
|
||
-- 19.01.2007 Webio
|
||
-- New Graphics java script base parameter
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.27
|
||
----------------------------------------------------------------
|
||
-- 09.11.2006 Webio
|
||
-- DHCP enable
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.26
|
||
----------------------------------------------------------------
|
||
-- 03.08.2006 wtWebGraphThermoBaroSensorNo korrigiert
|
||
--
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.25
|
||
----------------------------------------------------------------
|
||
-- 28.06.2006 New: Community String Trap
|
||
--
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.24
|
||
----------------------------------------------------------------
|
||
-- 26.07.2005 #57606, WebGraph Thermo-Hygrometer
|
||
-- CRON Zeitfunktion
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.23
|
||
----------------------------------------------------------------
|
||
-- 14.07.2005 #57606, WebGraph Thermo-Hygrometer
|
||
-- FTP Funktionen
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.22
|
||
----------------------------------------------------------------
|
||
-- 17.05.2005 #57606, WebGraph Thermo-Hygrometer
|
||
-- Trap NMS annotations
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.21
|
||
----------------------------------------------------------------
|
||
-- 19.04.2005 #57606, WebGraph Thermo-Hygrometer
|
||
-- Mail Authentication
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.20
|
||
----------------------------------------------------------------
|
||
-- 05.11.2004 #57606, WebGraph Themo-Hygrometer
|
||
-- Neu: Syslog
|
||
--
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.19
|
||
----------------------------------------------------------------
|
||
-- 08.09.2004 #57606 WebGraph Thermo-Hygrometer
|
||
-- Neu:
|
||
-- wtWebGraphThermoBaroAlarmRHMin
|
||
-- wtWebGraphThermoBaroAlarmRHMax
|
||
-- wtWebGraphThermoBaroAlarmRHHysteresis
|
||
-- wtWebGraphThermoBaroPortSensorSelect
|
||
-- wtWebGraphThermoBaroAlarmDeltaTemp
|
||
-- wtWebGraphThermoBaroAlarmAHMin
|
||
-- wtWebGraphThermoBaroAlarmAHMax
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.18
|
||
----------------------------------------------------------------
|
||
-- 21.07.2004 #57601/3/4, Webio Digital
|
||
-- Neu:
|
||
-- Diagnosis
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.17
|
||
----------------------------------------------------------------
|
||
-- 28.06.2004 #57630/1/2, Webio Digital
|
||
-- Neu: Puls Mode
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.16
|
||
----------------------------------------------------------------
|
||
-- 16.04.2004 neu: #57632, Webio Digital EA24x24
|
||
--
|
||
-- #57630/1, Webio Digital EA12x12
|
||
-- Neu:
|
||
-- wtWebioEA12x12InputCounterClear
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.15
|
||
----------------------------------------------------------------
|
||
-- 27.02.2004 #57630/1, Webio Digital EA12x12
|
||
-- Neu:
|
||
-- L<>nge erweitert auf 32 Bit:
|
||
-- wtWebioEA12x12InputValue
|
||
-- wtWebioEA12x12OutputValue
|
||
-- wtWebioEA12x12LoadControlView
|
||
-- wtWebioEA12x12LCShutDownView
|
||
-- wtWebioEA12x12SetOutput
|
||
-- wtWebioEA12x12AlarmInputTrigger
|
||
-- wtWebioEA12x12AlarmOutputTrigger
|
||
-- wtWebioEA12x12PortOutputSafetyState
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.14
|
||
----------------------------------------------------------------
|
||
-- 16.02.2004 #57630/1, Webio Digital EA12x12
|
||
-- Neu:
|
||
-- Texte: Location, Contact
|
||
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
|
||
-- Alarm: ColdStart / WarmStart trigger
|
||
--
|
||
-- #57601, 1xWebThermometer
|
||
-- #57603, 2xWebThermometer
|
||
-- #57604, 8xWebThermometer
|
||
-- Neu:
|
||
-- Alarm Hysterese
|
||
-- Alarm Clear Traps und Mails
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.13
|
||
----------------------------------------------------------------
|
||
-- 05.02.2004 #57601, 1xWebThermometer
|
||
-- #57603, 2xWebThermometer
|
||
-- #57604, 8xWebThermometer
|
||
-- Neu:
|
||
-- Texte: Location, Contact
|
||
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
|
||
-- Alarm: ColdStart / WarmStart trigger
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.12
|
||
----------------------------------------------------------------
|
||
-- 05.11.2003 #57601, 1xWebThermometer
|
||
-- #57603, 2xWebThermometer
|
||
-- #57604, 8xWebThermometer
|
||
-- Neu:
|
||
-- Mail Option: CSV attachment
|
||
-- Offsetkalibrierung
|
||
-- Alarm: Tcp Client mode
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.11
|
||
----------------------------------------------------------------
|
||
-- 28.10.2003 #57630/1, Webio Digital EA12x12
|
||
-- Neue Feature:
|
||
-- Alarm : TCP Client mode
|
||
-- INPUTS: Pulsfilter
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.10
|
||
----------------------------------------------------------------
|
||
-- 04.07.2003 #57630, Webio Digital EA12x12
|
||
-- Neuer Men<65>baum, neue Bin<69>rmodi
|
||
--
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.09
|
||
----------------------------------------------------------------
|
||
-- 24.03.2003 Trap Enterprise (Type 1, 2) korrigiert
|
||
--
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.08
|
||
----------------------------------------------------------------
|
||
-- 04.03.2003 Abgleich der Sprachversionen DE/US
|
||
--
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.07
|
||
----------------------------------------------------------------
|
||
-- 25.02.2003 Korrektur US: wtWebioEA12x12LoadControl
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.06
|
||
----------------------------------------------------------------
|
||
-- 24.02.2003 Neu:
|
||
-- #57630, Webio EA12x12, LoadControl Group
|
||
-- Korrektur: Trap variable Namen
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.05
|
||
----------------------------------------------------------------
|
||
-- 21.01.2003 Neu:
|
||
-- #57630, Webio EA12x12
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.04
|
||
----------------------------------------------------------------
|
||
-- 02.01.2003 Neu:
|
||
-- #57601, 1xWebThermometer
|
||
-- #57603, 2xWebThermometer, 8 Alarme
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.03
|
||
----------------------------------------------------------------
|
||
-- 21.11.2002 Neu:
|
||
-- #57604, 2xWebThermometer, BOOTP, StartupSite
|
||
-- #57603, 8xWebThermometer, BOOTP, StartupSite
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.02
|
||
----------------------------------------------------------------
|
||
-- 26.07.2002 Neu:
|
||
-- #57604, 2xWebThermometer
|
||
-- #57603, 8xWebThermometer
|
||
--
|
||
|
||
IMPORTS
|
||
|
||
OBJECT-TYPE FROM RFC-1212
|
||
TRAP-TYPE FROM RFC-1215
|
||
DisplayString, PhysAddress FROM RFC1213-MIB
|
||
enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
|
||
|
||
|
||
-- IpAddress ::=
|
||
-- [APPLICATION 0]
|
||
-- IMPLICIT OCTET STRING (SIZE (4))
|
||
-- Counter ::=
|
||
-- [APPLICATION 1]
|
||
-- IMPLICIT INTEGER (0..4294967295)
|
||
-- Gauge ::=
|
||
-- [APPLICATION 2]
|
||
-- IMPLICIT INTEGER (0..4294967295)
|
||
-- TimeTicks ::=
|
||
-- [APPLICATION 3]
|
||
-- IMPLICIT INTEGER (0..4294967295)
|
||
|
||
|
||
-- DisplayString ::= OCTET STRING
|
||
-- PhysAddress ::= OCTET STRING
|
||
|
||
-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
|
||
-- privat OBJECT IDENTIFIER ::= { internet 4 }
|
||
-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
|
||
|
||
|
||
|
||
-- Wiesemann & Theis Com-Server MIB
|
||
|
||
wut OBJECT IDENTIFIER ::= { enterprises 5040 }
|
||
wtComServer OBJECT IDENTIFIER ::= { wut 1 }
|
||
wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
|
||
|
||
|
||
-- wtWebGraph Tree
|
||
|
||
wtWebGraphThermoBaro OBJECT IDENTIFIER ::= { wtWebio 16 }
|
||
|
||
-- wtWebGraphThermoBaro Tree
|
||
|
||
wtWebGraphThermoBaroTemp OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 1 }
|
||
wtWebGraphThermoBaroSessCntrl OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 2 }
|
||
wtWebGraphThermoBaroConfig OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 3 }
|
||
wtWebGraphThermoBaroDiag OBJECT IDENTIFIER ::= { wtWebGraphThermoBaro 4 }
|
||
|
||
-- wtWebGraphThermoBaroConfig Tree
|
||
|
||
wtWebGraphThermoBaroDevice OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroConfig 1 }
|
||
wtWebGraphThermoBaroPorts OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroConfig 2 }
|
||
wtWebGraphThermoBaroManufact OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroConfig 3 }
|
||
|
||
-- wtWebGraphThermoBaroDevice Tree
|
||
|
||
wtWebGraphThermoBaroText OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 1 }
|
||
wtWebGraphThermoBaroTimeDate OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 2 }
|
||
wtWebGraphThermoBaroBasic OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 3 }
|
||
wtWebGraphThermoBaroDatalogger OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 4 }
|
||
wtWebGraphThermoBaroAlarm OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 5 }
|
||
wtWebGraphThermoBaroGraphics OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroDevice 6 }
|
||
|
||
-- wtWebGraphThermoBaroTimeDate Tree
|
||
|
||
wtWebGraphThermoBaroTimeZone OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroTimeDate 1 }
|
||
wtWebGraphThermoBaroTimeServer OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroTimeDate 2 }
|
||
wtWebGraphThermoBaroDeviceClock OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroTimeDate 3 }
|
||
|
||
-- wtWebGraphThermoBaroBasic Tree
|
||
|
||
wtWebGraphThermoBaroNetwork OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 1 }
|
||
wtWebGraphThermoBaroHTTP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 2 }
|
||
wtWebGraphThermoBaroMail OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 3 }
|
||
wtWebGraphThermoBaroSNMP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 4 }
|
||
wtWebGraphThermoBaroUDP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 5 }
|
||
wtWebGraphThermoBaroSyslog OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 6 }
|
||
wtWebGraphThermoBaroFTP OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 7 }
|
||
wtWebGraphThermoBaroRSS OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroBasic 8 }
|
||
|
||
-- wtWebGraphThermoBaroGraphics Tree
|
||
|
||
wtWebGraphThermoBaroGraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroGraphics 1 }
|
||
wtWebGraphThermoBaroGraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroGraphics 2 }
|
||
wtWebGraphThermoBaroGraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphThermoBaroGraphics 3 }
|
||
|
||
|
||
|
||
-- wtWebGraphThermoBaroTemp Group
|
||
------------------------
|
||
|
||
wtWebGraphThermoBaroSensors OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Anzahl der Sensoren"
|
||
::= { wtWebGraphThermoBaroTemp 1 }
|
||
|
||
-- Interface Table
|
||
|
||
wtWebGraphThermoBaroSensorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebGraphThermoBaroSensorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Liste der Sensoren."
|
||
::= { wtWebGraphThermoBaroTemp 2 }
|
||
|
||
wtWebGraphThermoBaroSensorEntry OBJECT-TYPE
|
||
SYNTAX WtWebGraphThermoBaroSensorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Nummern der Sensoren."
|
||
INDEX { wtWebGraphThermoBaroSensorNo }
|
||
::= { wtWebGraphThermoBaroSensorTable 1 }
|
||
|
||
WtWebGraphThermoBaroSensorEntry ::= SEQUENCE {
|
||
wtWebGraphThermoBaroSensorNo INTEGER
|
||
}
|
||
|
||
wtWebGraphThermoBaroSensorNo OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Nummer des Sensors."
|
||
::= { wtWebGraphThermoBaroSensorEntry 1 }
|
||
|
||
|
||
-- wtWebGraphThermoBaroTempValue Table
|
||
|
||
wtWebGraphThermoBaroTempValueTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebGraphThermoBaroTempValueEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Liste Sensormesswerte korrespondiernd zu den Kanalnummern."
|
||
::= { wtWebGraphThermoBaroTemp 3 }
|
||
|
||
wtWebGraphThermoBaroTempValueEntry OBJECT-TYPE
|
||
SYNTAX WtWebGraphThermoBaroTempValueEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Messwerte der Sensoren."
|
||
INDEX { wtWebGraphThermoBaroSensorNo }
|
||
::= { wtWebGraphThermoBaroTempValueTable 1 }
|
||
|
||
WtWebGraphThermoBaroTempValueEntry ::= SEQUENCE{
|
||
wtWebGraphThermoBaroTempValue OCTET STRING
|
||
}
|
||
|
||
wtWebGraphThermoBaroTempValue OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (5))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Messwert des Sensors, ASCII, 5 Zeichen lang."
|
||
::= { wtWebGraphThermoBaroTempValueEntry 1 }
|
||
|
||
-- wtWebGraphThermoBaroBinaryTempValue Table
|
||
|
||
wtWebGraphThermoBaroBinaryTempValueTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebGraphThermoBaroBinaryTempValueEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Liste bin<69>rer Messwerte korrespondiernd zu den Kanalnummern."
|
||
::= { wtWebGraphThermoBaroTemp 4 }
|
||
|
||
wtWebGraphThermoBaroBinaryTempValueEntry OBJECT-TYPE
|
||
SYNTAX WtWebGraphThermoBaroBinaryTempValueEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>re Messwerte der Sensoren."
|
||
INDEX { wtWebGraphThermoBaroSensorNo }
|
||
::= { wtWebGraphThermoBaroBinaryTempValueTable 1 }
|
||
|
||
WtWebGraphThermoBaroBinaryTempValueEntry ::= SEQUENCE{
|
||
wtWebGraphThermoBaroBinaryTempValue INTEGER
|
||
}
|
||
|
||
wtWebGraphThermoBaroBinaryTempValue OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>rer Messwert des Sensors in 1/10 Grad Celcius oder 1/10 Prozent,
|
||
vorzeichenbehaftete Zahl, der Wert 0x4FFF6 zeigt einen
|
||
ung<6E>ltigen Messwert an."
|
||
::= { wtWebGraphThermoBaroBinaryTempValueEntry 1 }
|
||
|
||
-- wtWebGraphThermoBaroTempValuePkt Table
|
||
|
||
wtWebGraphThermoBaroTempValuePktTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebGraphThermoBaroTempValuePktEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Liste Temperaturwerte korrespondiernd zu den Kanalnummern."
|
||
::= { wtWebGraphThermoBaroTemp 8 }
|
||
|
||
wtWebGraphThermoBaroTempValuePktEntry OBJECT-TYPE
|
||
SYNTAX WtWebGraphThermoBaroTempValuePktEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Temperaturen der Sensoren."
|
||
INDEX { wtWebGraphThermoBaroSensorNo }
|
||
::= { wtWebGraphThermoBaroTempValuePktTable 1 }
|
||
|
||
WtWebGraphThermoBaroTempValuePktEntry ::= SEQUENCE{
|
||
wtWebGraphThermoBaroTempValuePkt OCTET STRING
|
||
}
|
||
|
||
wtWebGraphThermoBaroTempValuePkt OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (5))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Temperaturwert des Sensors, ASCII, 5 Zeichen lang, dezimal Punkt."
|
||
::= { wtWebGraphThermoBaroTempValuePktEntry 1 }
|
||
|
||
-- wtWebGraphThermoBaroSessCntrl Group
|
||
--------------------------------
|
||
|
||
wtWebGraphThermoBaroSessCntrlPassword OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Durch Eintrag diese Passworts wird eine Session er<65>ffnet, die durch Schreiben einer 1
|
||
in wtWebGraphThermoBaroSessCntrlLogout beendet wird. Gelesen liefert diese Variable einen String der
|
||
L<>nge Null."
|
||
::= { wtWebGraphThermoBaroSessCntrl 1 }
|
||
|
||
wtWebGraphThermoBaroSessCntrlConfigMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebGraphThermoBaroSessCntrl-NoSession(0),
|
||
wtWebGraphThermoBaroSessCntrl-Session(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Wenn sich das Ger<65>t im SNMP-Konfigurationsmodus befindet, wird der Wert
|
||
1 zur<75>ckgeliefert, ansonsten 0. Ist der ausgelesene Wert 0
|
||
obwohl das Passwort geschrieben wurde, befindet sich das Ger<65>t bereits
|
||
im Configmodus und die Variablen k<>nnen nur gelesen werden."
|
||
::= { wtWebGraphThermoBaroSessCntrl 2 }
|
||
|
||
wtWebGraphThermoBaroSessCntrlLogout OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Wenn sich das Ger<65>t im Konfigurationsmodus befindet und die Session wurde
|
||
von diesem SNMP Manager er<65>ffnet, kann durch Schreiben einer 1 in diese
|
||
Variable die Session beendet werden und alle Parameter werden gespeichert.
|
||
Durch Schreiben einer 2 werden alle Eingaben wieder verworfen.
|
||
Gelesen liefert diese Variable den Wert 0."
|
||
::= { wtWebGraphThermoBaroSessCntrl 3 }
|
||
|
||
wtWebGraphThermoBaroSessCntrlAdminPassword OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Dieses Passwort sch<63>tzt den Zugang der Variablen mit Administratorrechten. Es kann nur vom
|
||
Administrator ver<65>ndert werden. Wurde kein Passwort vergeben so ist public das g<>ltige Passwort.
|
||
Gelesen liefert diese Variable einen Null-Pointer."
|
||
::= { wtWebGraphThermoBaroSessCntrl 4 }
|
||
|
||
wtWebGraphThermoBaroSessCntrlConfigPassword OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Dieses Passwort sch<63>tzt den Zugang der Variablen mit Configuratorrechten. Es kann vom
|
||
Administrator und vom Configurator ver<65>ndert werden. Wurde kein Passwort vergeben so ist
|
||
public das g<>ltige Passwort.Gelesen liefert diese Variable einen Null-Pointer."
|
||
::= { wtWebGraphThermoBaroSessCntrl 5 }
|
||
|
||
|
||
-- wtWebGraphThermoBaroText Group
|
||
------------------------
|
||
|
||
wtWebGraphThermoBaroDeviceName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name des Webio's, der userdefinierbar ist."
|
||
::= { wtWebGraphThermoBaroText 1 }
|
||
|
||
wtWebGraphThermoBaroDeviceText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Beschreibung des Webio's, die userdefinierbar ist."
|
||
::= { wtWebGraphThermoBaroText 2 }
|
||
|
||
wtWebGraphThermoBaroDeviceLocation OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Aufstellort des Webio's, die userdefinierbar ist."
|
||
::= { wtWebGraphThermoBaroText 3 }
|
||
|
||
wtWebGraphThermoBaroDeviceContact OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Kontaktadresse im Servicefall des Webio's, die userdefinierbar ist."
|
||
::= { wtWebGraphThermoBaroText 4 }
|
||
|
||
-- wtWebGraphThermoBaroTimeZone Group
|
||
----------------------------
|
||
|
||
wtWebGraphThermoBaroTzOffsetHrs OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset Stunden der Zeitzone (Winterzeit) in Bezug auf UTC."
|
||
::= { wtWebGraphThermoBaroTimeZone 1 }
|
||
|
||
wtWebGraphThermoBaroTzOffsetMin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset Minuten der Zeitzone (Winterzeit) in Bezug auf UTC."
|
||
::= { wtWebGraphThermoBaroTimeZone 2 }
|
||
|
||
wtWebGraphThermoBaroTzEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>r kodierte Bedingung:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 1-7: ungenutzt
|
||
Bit 0 : Apply Timezone"
|
||
::= { wtWebGraphThermoBaroTimeZone 3 }
|
||
|
||
wtWebGraphThermoBaroStTzOffsetHrs OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset Stunden der Zeitzone (Sommerzeit) in Bezug auf UTC."
|
||
::= { wtWebGraphThermoBaroTimeZone 4 }
|
||
|
||
wtWebGraphThermoBaroStTzOffsetMin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset Minuten der Zeitzone (Sommerzeit) in Bezug auf UTC."
|
||
::= { wtWebGraphThermoBaroTimeZone 5 }
|
||
|
||
wtWebGraphThermoBaroStTzEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>r kodierte Bedingung:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 1-7: ungenutzt
|
||
Bit 0 : Apply Summertime"
|
||
::= { wtWebGraphThermoBaroTimeZone 6 }
|
||
|
||
wtWebGraphThermoBaroStTzStartMonth OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebGraphThermoBaroStartMonth-January(1),
|
||
wtWebGraphThermoBaroStartMonth-February(2),
|
||
wtWebGraphThermoBaroStartMonth-March(3),
|
||
wtWebGraphThermoBaroStartMonth-April(4),
|
||
wtWebGraphThermoBaroStartMonth-May(5),
|
||
wtWebGraphThermoBaroStartMonth-June(6),
|
||
wtWebGraphThermoBaroStartMonth-July(7),
|
||
wtWebGraphThermoBaroStartMonth-August(8),
|
||
wtWebGraphThermoBaroStartMonth-September(9),
|
||
wtWebGraphThermoBaroStartMonth-October(10),
|
||
wtWebGraphThermoBaroStartMonth-November(11),
|
||
wtWebGraphThermoBaroStartMonth-December(12)
|
||
}
|
||
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Monat, in dem von Winterzeit auf Sommerzeit umgestellt wird."
|
||
::= { wtWebGraphThermoBaroTimeZone 7 }
|
||
|
||
wtWebGraphThermoBaroStTzStartMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebGraphThermoBaroStartMode-first(1),
|
||
wtWebGraphThermoBaroStartMode-second(2),
|
||
wtWebGraphThermoBaroStartMode-third(3),
|
||
wtWebGraphThermoBaroStartMode-fourth(4),
|
||
wtWebGraphThermoBaroStartMode-last(5)
|
||
}
|
||
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Modus des Wochentages, bei dem von Winterzeit auf Sommerzeit umgestellt wird."
|
||
::= { wtWebGraphThermoBaroTimeZone 8 }
|
||
|
||
wtWebGraphThermoBaroStTzStartWday OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebGraphThermoBaroStartWday-Sunday(1),
|
||
wtWebGraphThermoBaroStartWday-Monday(2),
|
||
wtWebGraphThermoBaroStartWday-Tuesday(3),
|
||
wtWebGraphThermoBaroStartWday-Thursday(4),
|
||
wtWebGraphThermoBaroStartWday-Wednesday(5),
|
||
wtWebGraphThermoBaroStartWday-Friday(6),
|
||
wtWebGraphThermoBaroStartWday-Saturday(7)
|
||
}
|
||
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Wochentag, bei dem von Winterzeit auf Sommerzeit umgestellt wird"
|
||
::= { wtWebGraphThermoBaroTimeZone 9 }
|
||
|
||
wtWebGraphThermoBaroStTzStartHrs OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Stunde, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC
|
||
umgestellt wird."
|
||
::= { wtWebGraphThermoBaroTimeZone 10 }
|
||
|
||
wtWebGraphThermoBaroStTzStartMin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Minute, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC
|
||
umgestellt wird."
|
||
::= { wtWebGraphThermoBaroTimeZone 11 }
|
||
|
||
wtWebGraphThermoBaroStTzStopMonth OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebGraphThermoBaroStopMonth-January(1),
|
||
wtWebGraphThermoBaroStopMonth-February(2),
|
||
wtWebGraphThermoBaroStopMonth-March(3),
|
||
wtWebGraphThermoBaroStopMonth-April(4),
|
||
wtWebGraphThermoBaroStopMonth-May(5),
|
||
wtWebGraphThermoBaroStopMonth-June(6),
|
||
wtWebGraphThermoBaroStopMonth-July(7),
|
||
wtWebGraphThermoBaroStopMonth-August(8),
|
||
wtWebGraphThermoBaroStopMonth-September(9),
|
||
wtWebGraphThermoBaroStopMonth-October(10),
|
||
wtWebGraphThermoBaroStopMonth-November(11),
|
||
wtWebGraphThermoBaroStopMonth-December(12)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Monat, bei dem von Sommerzeit auf Winterzeit umgestellt wird."
|
||
::= { wtWebGraphThermoBaroTimeZone 12 }
|
||
|
||
wtWebGraphThermoBaroStTzStopMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebGraphThermoBaroStopMode-first(1),
|
||
wtWebGraphThermoBaroStopMode-second(2),
|
||
wtWebGraphThermoBaroStopMode-third(3),
|
||
wtWebGraphThermoBaroStopMode-fourth(4),
|
||
wtWebGraphThermoBaroStopMode-last(5)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Modus des Wochentages, bei dem von Sommerzeit auf Winterzeit umgestellt wird."
|
||
::= { wtWebGraphThermoBaroTimeZone 13 }
|
||
|
||
wtWebGraphThermoBaroStTzStopWday OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebGraphThermoBaroStopWday-Sunday(1),
|
||
wtWebGraphThermoBaroStopWday-Monday(2),
|
||
wtWebGraphThermoBaroStopWday-Tuesday(3),
|
||
wtWebGraphThermoBaroStopWday-Thursday(4),
|
||
wtWebGraphThermoBaroStopWday-Wednesday(5),
|
||
wtWebGraphThermoBaroStopWday-Friday(6),
|
||
wtWebGraphThermoBaroStopWday-Saturday(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Wochentage, bei dem von Sommerzeit auf Winterzeit umgestellt wird."
|
||
::= { wtWebGraphThermoBaroTimeZone 14 }
|
||
|
||
wtWebGraphThermoBaroStTzStopHrs OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Stunde, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC
|
||
umgestellt wird."
|
||
::= { wtWebGraphThermoBaroTimeZone 15 }
|
||
|
||
wtWebGraphThermoBaroStTzStopMin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Minute, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC
|
||
umgestellt wird."
|
||
::= { wtWebGraphThermoBaroTimeZone 16 }
|
||
|
||
-- wtWebGraphThermoBaroTimeServer Group
|
||
----------------------------
|
||
|
||
wtWebGraphThermoBaroTimeServer1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP-Adresse oder Name des 1. Time Servers in ASCII"
|
||
::= { wtWebGraphThermoBaroTimeServer 1 }
|
||
|
||
wtWebGraphThermoBaroTimeServer2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP-Adresse oder Name des 2. Time Servers in ASCII"
|
||
::= { wtWebGraphThermoBaroTimeServer 2 }
|
||
|
||
wtWebGraphThermoBaroTsEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>r kodierte Bedingung:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 1-7: ungenutzt
|
||
Bit 0 : Apply Time Server"
|
||
::= { wtWebGraphThermoBaroTimeServer 3 }
|
||
|
||
wtWebGraphThermoBaroTsSyncTime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Die Abfrage der Timeserver erfolgt zu dieser vollen Stunde (0-23)."
|
||
::= { wtWebGraphThermoBaroTimeServer 4 }
|
||
|
||
-- wtWebGraphThermoBaroDeviceClock Group
|
||
----------------------------
|
||
|
||
wtWebGraphThermoBaroClockHrs OBJECT-TYPE
|
||
SYNTAX INTEGER (0..23)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Uhrzeit Stunde, unter Ber<65>cksichtigung der Zeitzoneneinstellungen."
|
||
::= { wtWebGraphThermoBaroDeviceClock 1 }
|
||
|
||
wtWebGraphThermoBaroClockMin OBJECT-TYPE
|
||
SYNTAX INTEGER (0..59)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Uhrzeit Minute, unter Ber<65>cksichtigung der Zeitzoneneinstellungen."
|
||
::= { wtWebGraphThermoBaroDeviceClock 2 }
|
||
|
||
wtWebGraphThermoBaroClockDay OBJECT-TYPE
|
||
SYNTAX INTEGER (1..31)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Datum: Tag des Monats, unter Ber<65>cksichtigung der Zeitzoneneinstellungen."
|
||
::= { wtWebGraphThermoBaroDeviceClock 3 }
|
||
|
||
wtWebGraphThermoBaroClockMonth OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebGraphThermoBaroClockMonth-January(1),
|
||
wtWebGraphThermoBaroClockMonth-February(2),
|
||
wtWebGraphThermoBaroClockMonth-March(3),
|
||
wtWebGraphThermoBaroClockMonth-April(4),
|
||
wtWebGraphThermoBaroClockMonth-May(5),
|
||
wtWebGraphThermoBaroClockMonth-June(6),
|
||
wtWebGraphThermoBaroClockMonth-July(7),
|
||
wtWebGraphThermoBaroClockMonth-August(8),
|
||
wtWebGraphThermoBaroClockMonth-September(9),
|
||
wtWebGraphThermoBaroClockMonth-October(10),
|
||
wtWebGraphThermoBaroClockMonth-November(11),
|
||
wtWebGraphThermoBaroClockMonth-December(12)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Datum: Monat, unter Ber<65>cksichtigung der Zeitzoneneinstellungen."
|
||
::= { wtWebGraphThermoBaroDeviceClock 4 }
|
||
|
||
wtWebGraphThermoBaroClockYear OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Datum: Jahr, unter Ber<65>cksichtigung der Zeitzoneneinstellungen."
|
||
::= { wtWebGraphThermoBaroDeviceClock 5 }
|
||
|
||
|
||
-- wtWebGraphThermoBaroNetwork Group
|
||
------------------------
|
||
|
||
wtWebGraphThermoBaroIpAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP-Adresse des Webio's"
|
||
::= { wtWebGraphThermoBaroNetwork 1 }
|
||
|
||
wtWebGraphThermoBaroSubnetMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Subnetmask des Webio's"
|
||
::= { wtWebGraphThermoBaroNetwork 2 }
|
||
|
||
wtWebGraphThermoBaroGateway OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Gateway des Webio's"
|
||
::= { wtWebGraphThermoBaroNetwork 3 }
|
||
|
||
wtWebGraphThermoBaroDnsServer1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP-Adresse des 1. DNS Servers in ASCII"
|
||
::= { wtWebGraphThermoBaroNetwork 4 }
|
||
|
||
wtWebGraphThermoBaroDnsServer2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP-Adresse des 2. DNS Servers in ASCII"
|
||
::= { wtWebGraphThermoBaroNetwork 5 }
|
||
|
||
wtWebGraphThermoBaroAddConfig OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Zusatzkonfiguration (1=EIN):
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 1: DHCP disable
|
||
Bit 0: BOOTP disable
|
||
"
|
||
::= { wtWebGraphThermoBaroNetwork 6 }
|
||
|
||
-- wtWebGraphThermoBaroHTTP Group
|
||
--------------------------------
|
||
|
||
wtWebGraphThermoBaroStartup OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Legt die Startseite fest, nur eine Auswahl zul<75>ssig:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 2: user.htm
|
||
Bit 1: home.htm
|
||
Bit 0: index.htm"
|
||
::= { wtWebGraphThermoBaroHTTP 1 }
|
||
|
||
wtWebGraphThermoBaroGetHeaderEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Wenn freigeschaltet, wird eine Erkennungssequenz und /oder ein HTTP-Kopf nach
|
||
jeder GET-Anfrage der Antwort vorangestellt:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 1-6: ungenutzt
|
||
Bit 1 : GET HTTP enable
|
||
Bit 0 : GET Header enable"
|
||
::= { wtWebGraphThermoBaroHTTP 2 }
|
||
|
||
wtWebGraphThermoBaroHttpPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"HTTP Port, an den die TCP-Anfragen gesendet werden k<>nnen (Default: 80)."
|
||
::= { wtWebGraphThermoBaroHTTP 3 }
|
||
|
||
-- wtWebGraphThermoBaroMail Group
|
||
--------------------------------
|
||
|
||
wtWebGraphThermoBaroMailAdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Ger<65>tename f<>r die Mail-Administration."
|
||
::= { wtWebGraphThermoBaroMail 1 }
|
||
|
||
wtWebGraphThermoBaroMailReply OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Reply-Adresse f<>r den Mailserver."
|
||
::= { wtWebGraphThermoBaroMail 2 }
|
||
|
||
wtWebGraphThermoBaroMailServer OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name oder Ip-Adresse des Mailservers."
|
||
::= { wtWebGraphThermoBaroMail 3 }
|
||
|
||
wtWebGraphThermoBaroMailEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Erlaubt das versenden von Mails:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 1-7: ungenutzt
|
||
Bit 0 : Mail enable"
|
||
::= { wtWebGraphThermoBaroMail 4 }
|
||
|
||
wtWebGraphThermoBaroMailAuthentication OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Auswahl des Authenticationmodi:
|
||
die OCTETS werden bitweise interpretiert, es darf nur ein Bit gesetzt sein.
|
||
Bit 0 entspricht dem LSB.
|
||
OCTET 1: ungenutzt
|
||
OCTET 2: ungenutzt
|
||
OCTET 3: ungenutzt
|
||
OCTET 4: Bit 3-7: ungenutzt
|
||
Bit 2 : POP3 vor SMTP
|
||
Bit 1 : ESMTP, Authentifizierung
|
||
Bit 0 : SMTP, keine Authentifizierung"
|
||
::= { wtWebGraphThermoBaroMail 5 }
|
||
|
||
wtWebGraphThermoBaroMailAuthUser OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name des Postfaches / Postfachusers."
|
||
::= { wtWebGraphThermoBaroMail 6 }
|
||
|
||
wtWebGraphThermoBaroMailAuthPassword OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Passwort zur Identifizierung des Users."
|
||
::= { wtWebGraphThermoBaroMail 7 }
|
||
|
||
wtWebGraphThermoBaroMailPop3Server OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name oder Ip-Adresse des POP3 Servers."
|
||
::= { wtWebGraphThermoBaroMail 8 }
|
||
|
||
-- wtWebGraphThermoBaroSNMP Group
|
||
--------------------------------
|
||
|
||
wtWebGraphThermoBaroSnmpCommunityStringRead OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Community string read only"
|
||
::= { wtWebGraphThermoBaroSNMP 1 }
|
||
|
||
wtWebGraphThermoBaroSnmpCommunityStringReadWrite OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Community string read / write"
|
||
::= { wtWebGraphThermoBaroSNMP 2 }
|
||
|
||
wtWebGraphThermoBaroSystemTrapManagerIP OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name oder IP-Adresse des SNMP-Managers, der den System Trap entgegen nimmt."
|
||
::= { wtWebGraphThermoBaroSNMP 3 }
|
||
|
||
wtWebGraphThermoBaroSystemTrapEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>r kodierte Triggerbedingungen:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0: ColdStart
|
||
Bit 1: WarmStart
|
||
Bit 2-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroSNMP 4 }
|
||
|
||
wtWebGraphThermoBaroSnmpEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bit 0 schaltet SNMP frei:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 1-7: ungenutzt
|
||
Bit 0 : SNMP enable"
|
||
::= { wtWebGraphThermoBaroSNMP 5 }
|
||
|
||
wtWebGraphThermoBaroSnmpCommunityStringTrap OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Community string der Traps."
|
||
::= { wtWebGraphThermoBaroSNMP 6 }
|
||
|
||
|
||
-- wtWebGraphThermoBaroUDP Group
|
||
--------------------------------
|
||
|
||
wtWebGraphThermoBaroUdpPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Udp Port, an den die Udp-Anfragen GET Single gesendet werden k<>nnen"
|
||
::= { wtWebGraphThermoBaroUDP 1 }
|
||
|
||
wtWebGraphThermoBaroUdpEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Schaltet UDP frei:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 1-7: ungenutzt
|
||
Bit 0 : UDP enable"
|
||
::= { wtWebGraphThermoBaroUDP 2 }
|
||
|
||
-- wtWebGraphThermoBaroSyslog Group
|
||
--------------------------------
|
||
|
||
wtWebGraphThermoBaroSyslogServerIP OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name oder IP-Adresse des Syslog-Servers, der die Syslog-Nachricht entgegen nimmt."
|
||
::= { wtWebGraphThermoBaroSyslog 1 }
|
||
|
||
wtWebGraphThermoBaroSyslogServerPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Portnummer des Syslog-Servers, default ist 514."
|
||
::= { wtWebGraphThermoBaroSyslog 2 }
|
||
|
||
wtWebGraphThermoBaroSyslogSystemMessagesEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>r kodierte Triggerbedingungen:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0: ColdStart
|
||
Bit 1: WarmStart
|
||
Bit 2: Diag Messages
|
||
Bit 3-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroSyslog 3 }
|
||
|
||
wtWebGraphThermoBaroSyslogEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bit 0 schaltet Syslog frei:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 1-7: ungenutzt
|
||
Bit 0 : Syslog enable"
|
||
::= { wtWebGraphThermoBaroSyslog 4 }
|
||
|
||
-- wtWebGraphThermoBaroFTP Group
|
||
--------------------------------
|
||
|
||
wtWebGraphThermoBaroFTPServerIP OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name oder IP-Adresse des FTP-Servers, der die FTP-Nachricht entgegen nimmt."
|
||
::= { wtWebGraphThermoBaroFTP 1 }
|
||
|
||
wtWebGraphThermoBaroFTPServerControlPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Portnummer des Kontrollports des FTP-Servers, default ist 21."
|
||
::= { wtWebGraphThermoBaroFTP 2 }
|
||
|
||
wtWebGraphThermoBaroFTPUserName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"FTP Loggin: Name des Anwenders."
|
||
::= { wtWebGraphThermoBaroFTP 3 }
|
||
|
||
wtWebGraphThermoBaroFTPPassword OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"FTP Loggin: Passwort des Anwenders."
|
||
::= { wtWebGraphThermoBaroFTP 4 }
|
||
|
||
wtWebGraphThermoBaroFTPAccount OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"FTP Loggin: Account-Name des Anwenderkontos."
|
||
::= { wtWebGraphThermoBaroFTP 5 }
|
||
|
||
wtWebGraphThermoBaroFTPOption OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bit 0 schaltet den FTP Server in den Passiv-Modus,
|
||
der Client kontrolliert die Datenverbindung allein:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 1-7: ungenutzt
|
||
Bit 0 : PASV enable"
|
||
::= { wtWebGraphThermoBaroFTP 6 }
|
||
|
||
wtWebGraphThermoBaroFTPEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bit 0 schaltet FTP frei:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 1-7: ungenutzt
|
||
Bit 0 : FTP enable"
|
||
::= { wtWebGraphThermoBaroFTP 7 }
|
||
|
||
|
||
-- wtWebGraphThermoBaroDatalogger Group
|
||
--------------------------------
|
||
|
||
wtWebGraphThermoBaroLoggerTimebase OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebGraphThermoBaroDatalogger-1Min(1),
|
||
wtWebGraphThermoBaroDatalogger-5Min(2),
|
||
wtWebGraphThermoBaroDatalogger-15Min(3),
|
||
wtWebGraphThermoBaroDatalogger-60Min(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Zeitbasis des Dataloggers"
|
||
::= { wtWebGraphThermoBaroDatalogger 1 }
|
||
|
||
wtWebGraphThermoBaroLoggerSensorSel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>r kodierte Triggerbedingungen:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0 : Sensor 1
|
||
Bit 1 : Sensor 2
|
||
Bit 2-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroDatalogger 2 }
|
||
|
||
|
||
-- wtWebGraphThermoBaroRSS Group
|
||
--------------------------------
|
||
|
||
wtWebGraphThermoBaroRSSChannelTitle OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name des RSS Feeds."
|
||
::= { wtWebGraphThermoBaroRSS 1 }
|
||
|
||
wtWebGraphThermoBaroRSSChannelLink OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Link des RSS Feeds."
|
||
::= { wtWebGraphThermoBaroRSS 2 }
|
||
|
||
wtWebGraphThermoBaroRSSChannelDescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Beschreibungstext des RSS Feeds."
|
||
::= { wtWebGraphThermoBaroRSS 3 }
|
||
|
||
wtWebGraphThermoBaroRSSChannelImage OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Link zu eine Bild, dass mit dem Datens<6E>tzen in der Kopfzeile angezeigt wird."
|
||
::= { wtWebGraphThermoBaroRSS 4 }
|
||
|
||
wtWebGraphThermoBaroRSSChannelImageTitle OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name des Bildes."
|
||
::= { wtWebGraphThermoBaroRSS 5 }
|
||
|
||
wtWebGraphThermoBaroRSSChannelImageLink OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Link, der dem Bild in der Kopfzeile hinterlegt wird."
|
||
::= { wtWebGraphThermoBaroRSS 6 }
|
||
|
||
wtWebGraphThermoBaroRSSChannelItemTitle OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name des RSS Feeds Eintrages."
|
||
::= { wtWebGraphThermoBaroRSS 7 }
|
||
|
||
wtWebGraphThermoBaroRSSChannelItemLink OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Link des RSS Feeds Eintrages."
|
||
::= { wtWebGraphThermoBaroRSS 8 }
|
||
|
||
wtWebGraphThermoBaroRSSChannelItemDescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Text des RSS Feeds Eintrages."
|
||
::= { wtWebGraphThermoBaroRSS 9 }
|
||
|
||
wtWebGraphThermoBaroRSSChannelItemQuantity OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Anzahl der auszugebenen RSS Feeds Eintr<74>ge."
|
||
::= { wtWebGraphThermoBaroRSS 10 }
|
||
|
||
-- wtWebGraphThermoBaroAlarm Group
|
||
--------------------------------
|
||
|
||
wtWebGraphThermoBaroAlarmCount OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Anzahl der unabh<62>ngigen Alarme."
|
||
::= { wtWebGraphThermoBaroAlarm 1 }
|
||
|
||
-- Alarm Interface Table
|
||
|
||
wtWebGraphThermoBaroAlarmIfTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebGraphThermoBaroAlarmIfEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Liste der Alarmindizes."
|
||
::= { wtWebGraphThermoBaroAlarm 2 }
|
||
|
||
wtWebGraphThermoBaroAlarmIfEntry OBJECT-TYPE
|
||
SYNTAX WtWebGraphThermoBaroAlarmIfEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Nummern der Alarme."
|
||
INDEX { wtWebGraphThermoBaroAlarmNo }
|
||
::= { wtWebGraphThermoBaroAlarmIfTable 1 }
|
||
|
||
WtWebGraphThermoBaroAlarmIfEntry ::= SEQUENCE {
|
||
wtWebGraphThermoBaroAlarmNo INTEGER
|
||
}
|
||
|
||
wtWebGraphThermoBaroAlarmNo OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Nummer des Alarms."
|
||
::= { wtWebGraphThermoBaroAlarmIfEntry 1 }
|
||
|
||
-- Alarm Table
|
||
|
||
wtWebGraphThermoBaroAlarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebGraphThermoBaroAlarmEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Liste der Einstellungen abh<62>ngig von der Alarmnummer."
|
||
::= { wtWebGraphThermoBaroAlarm 3 }
|
||
|
||
wtWebGraphThermoBaroAlarmEntry OBJECT-TYPE
|
||
SYNTAX WtWebGraphThermoBaroAlarmEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm-Parameter der einzelnen Alarme."
|
||
INDEX { wtWebGraphThermoBaroAlarmNo }
|
||
::= { wtWebGraphThermoBaroAlarmTable 1 }
|
||
|
||
WtWebGraphThermoBaroAlarmEntry ::= SEQUENCE {
|
||
wtWebGraphThermoBaroAlarmTrigger OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmMin OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmMax OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmHysteresis OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmDelay OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmInterval OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmEnable OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmEMailAddr OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmMailSubject OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmMailText OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmManagerIP OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmTrapText OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmMailOptions OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmTcpIpAddr OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmTcpPort INTEGER,
|
||
wtWebGraphThermoBaroAlarmTcpText OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmClearMailSubject OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmClearMailText OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmClearTrapText OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmClearTcpText OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmDeltaTemp OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmRHMin OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmRHMax OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmRHHysteresis OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmAHMin OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmAHMax OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmSyslogIpAddr OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmSyslogPort INTEGER,
|
||
wtWebGraphThermoBaroAlarmSyslogText OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmSyslogClearText OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmFtpDataPort OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmFtpFileName OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmFtpText OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmFtpClearText OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmFtpOption OCTET STRING,
|
||
wtWebGraphThermoBaroAlarmTimerCron OCTET STRING
|
||
|
||
}
|
||
|
||
wtWebGraphThermoBaroAlarmTrigger OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>r kodierte Triggerbedingungen:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3:
|
||
Bit 0: Timer
|
||
Bit 1: ColdStart
|
||
Bit 2: WarmStart
|
||
Bit 3: Sensor lost
|
||
Bit 4-7 ungenutzt
|
||
Octet 4:
|
||
Bit 0: Sensor 1
|
||
Bit 1: Sensor 2
|
||
Bit 2-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroAlarmEntry 1 }
|
||
|
||
wtWebGraphThermoBaroAlarmMin OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Minimum Temperatur in Grad mit maximal 2 Nachkommastellen."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 2 }
|
||
|
||
wtWebGraphThermoBaroAlarmMax OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximum Temperatur in Grad mit maximal 2 Nachkommastellen."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 3 }
|
||
|
||
wtWebGraphThermoBaroAlarmHysteresis OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bei <20>berschreiten der Temperatur Min+Hyst. und Unterschreiten der Temperatur Max-Hyst.
|
||
wird der Alarm gel<65>scht: pos. Temperaturdifferenz in Grad mit maximal 2 Nachkommastellen."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 4 }
|
||
|
||
wtWebGraphThermoBaroAlarmDelay OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Der Alarm wird erst ausgel<65>st, wenn f<>r die Dauer dieser Zeit
|
||
die Alarmbedingungen erf<72>llt sind (Zeit in Minuten)."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 5 }
|
||
|
||
wtWebGraphThermoBaroAlarmInterval OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Sendeintervall von Alarmmeldungen."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 6 }
|
||
|
||
wtWebGraphThermoBaroAlarmEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>r kodierte Alarmfreischaltung:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0: Mail Enable
|
||
Bit 1: SNMP Trap enable
|
||
Bit 2: TCP Client enable"
|
||
::= { wtWebGraphThermoBaroAlarmEntry 7 }
|
||
|
||
wtWebGraphThermoBaroAlarmEMailAddr OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"E-Mail Adresse, an die die Alarmmail gesendet werden soll."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 8 }
|
||
|
||
wtWebGraphThermoBaroAlarmMailSubject OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Betreffzeile der Alarmmail."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 9 }
|
||
|
||
wtWebGraphThermoBaroAlarmMailText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Text der Alarmmail: <Tn> liefert die aktuelle Temperatur; n = 1..8.
|
||
<Z> liefert die aktuelle Zeit."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 10 }
|
||
|
||
wtWebGraphThermoBaroAlarmManagerIP OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name oder IP-Adresse des SNMP-Managers, der den Trap entgegen nimmt."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 11 }
|
||
|
||
wtWebGraphThermoBaroAlarmTrapText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Dieser Text wird im Trapbody gesendet."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 12 }
|
||
|
||
wtWebGraphThermoBaroAlarmMailOptions OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>r kodierte Optionen:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0 : Attach Thermo.csv Enable
|
||
Bit 1 : CSV-Data_since_last_report
|
||
Bit 2-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroAlarmEntry 13 }
|
||
|
||
wtWebGraphThermoBaroAlarmTcpIpAddr OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP-Adresse des Ger<65>tes, dass eine TCP-Nachricht empfangen soll."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 14 }
|
||
|
||
wtWebGraphThermoBaroAlarmTcpPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Portnummer des Ger<65>tes, dass eine TCP-Nachricht empfangen soll."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 15 }
|
||
|
||
wtWebGraphThermoBaroAlarmTcpText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Dieser Text wird im TCP Trapbody gesendet."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 16 }
|
||
|
||
wtWebGraphThermoBaroAlarmClearMailSubject OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Betreffzeile der Alarm Clear Mail."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 17 }
|
||
|
||
wtWebGraphThermoBaroAlarmClearMailText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Text der Alarm Clear Mail: <Tn> liefert die aktuelle Temperatur; n = 1..8.
|
||
<Z> liefert die aktuelle Zeit."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 18 }
|
||
|
||
wtWebGraphThermoBaroAlarmClearTrapText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Dieser Text wird im Trapbody gesendet."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 19 }
|
||
|
||
wtWebGraphThermoBaroAlarmClearTcpText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Dieser Text wird im TCP Trapbody gesendet."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 20 }
|
||
|
||
wtWebGraphThermoBaroAlarmDeltaTemp OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximale Temperatur<75>nderung in Grad/min mit maximal 2 Nachkommastellen.
|
||
Es wird ein Mittelwert einer Periode von 5 Minuten verglichen."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 21 }
|
||
|
||
wtWebGraphThermoBaroAlarmRHMin OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Minimum rel. Feuchte in Prozent mit maximal 2 Nachkommastellen."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 22 }
|
||
|
||
wtWebGraphThermoBaroAlarmRHMax OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximum rel.Feuchte in Prozent mit maximal 2 Nachkommastellen."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 23 }
|
||
|
||
wtWebGraphThermoBaroAlarmRHHysteresis OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Hysterese rel. Feuchte in Prozent mit maximal 2 Nachkommastellen."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 24 }
|
||
|
||
wtWebGraphThermoBaroAlarmAHMin OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Minimum abs. Feuchte in g/(m*m*m) mit maximal 2 Nachkommastellen."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 25 }
|
||
|
||
wtWebGraphThermoBaroAlarmAHMax OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximum abs. Feuchte in g/(m*m*m) mit maximal 2 Nachkommastellen."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 26 }
|
||
|
||
wtWebGraphThermoBaroAlarmSyslogIpAddr OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP-Adresse des Ger<65>tes, dass eine Syslog-Nachricht empfangen soll."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 27 }
|
||
|
||
wtWebGraphThermoBaroAlarmSyslogPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Portnummer des Ger<65>tes, dass eine Syslog-Nachricht empfangen soll, default Port ist 514."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 28 }
|
||
|
||
wtWebGraphThermoBaroAlarmSyslogText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Jede Syslog-Nachricht beginnt mit einem Priorit<69>tsschl<68>ssel, einem Zeitstempel und der Host Ip-Nummer gem<65><6D> RFC3164.
|
||
Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 29 }
|
||
|
||
wtWebGraphThermoBaroAlarmSyslogClearText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Jede Syslog-Nachricht beginnt mit einem Priorit<69>tsschl<68>ssel, einem Zeitstempel und der Host Ip-Nummer gem<65><6D> RFC3164.
|
||
Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 30 }
|
||
|
||
wtWebGraphThermoBaroAlarmFtpDataPort OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Lokaler Datenport: 1..65535 oder AUTO: der n<>chste ungenutzte Port wird automatisch zugewiesen."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 31 }
|
||
|
||
wtWebGraphThermoBaroAlarmFtpFileName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Der File Name kann auch Pfadinformationen enthalten."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 32 }
|
||
|
||
wtWebGraphThermoBaroAlarmFtpText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Dieser Text wird in die angegebene Datei geschrieben."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 33 }
|
||
|
||
wtWebGraphThermoBaroAlarmFtpClearText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Dieser Text wird in die angegebene Datei geschrieben."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 34 }
|
||
|
||
wtWebGraphThermoBaroAlarmFtpOptions OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>r kodierte Optionen, nur eine Option darf eingeschaltet sein:
|
||
STORE = Datei ersetzen
|
||
APPEND = Nachrichten ans Dateiende anh<6E>ngen
|
||
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0 : STORE
|
||
Bit 1 : APPEND
|
||
Bit 2-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroAlarmEntry 35 }
|
||
|
||
wtWebGraphThermoBaroAlarmTimerCron OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Dieser Eintrag enth<74>lt 5 Leerzeichen- oder Tab-getrente Felder zur Definition von zeitgesteuerten
|
||
Ausgabe von Alarmnachrichten. Jedes der 5 Felder muss mit der aktuelle Zeit <20>bereinstimmen, um
|
||
das Senden einer Nachricht auszul<75>sen, Wochentag und Monatstag werden getrennt ausgewertet.
|
||
Feld m<>glicher Zahlenbereich
|
||
1: Minuten 0-59
|
||
2. Stunden 0-23, 0 ist Mitternacht
|
||
3: Monatstag 1-31
|
||
4: Monat 1-12
|
||
5: Wochentag 0-6, 0 ist Sonntag
|
||
|
||
F<>r jedes Feld kann nun angegeben werden:
|
||
- eine ganze Zahl aus dem angegebenen Zahlenbereich
|
||
- ein Teil-Zahlenbereich (wie z.B. 1-5) innerhalb des angegebenen Zahlenbereichs
|
||
- eine mit Komma getrennte Liste von ganzen Zahlen oder Tei-Zahlenbereichen (wie z.B. 2,4-6,8,10)
|
||
- ein Stern * (deckt den gesamten erlaubten Bereich ab)
|
||
- ein / gibt die Schrittweite bei Teil-Zahlenbereichen an (z.B. 0-59/2 jede zweite Minute)."
|
||
::= { wtWebGraphThermoBaroAlarmEntry 36 }
|
||
|
||
-- wtWebGraphThermoBaroGraphicsBase Group
|
||
----------------------------
|
||
|
||
wtWebGraphThermoBaroGraphicsBaseEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Legt die Anzeigeelemente der Grafik fest:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0 : Auto scroll enable
|
||
Bit 1 : Show table
|
||
Bit 2 : Show graph
|
||
Bit 3 : Show control buttons
|
||
Bit 4 : Show config menu
|
||
Bit 5-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroGraphicsBase 1 }
|
||
|
||
wtWebGraphThermoBaroGraphicsBaseWidth OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Definiert die Breite der Grafik in Pixeln."
|
||
::= { wtWebGraphThermoBaroGraphicsBase 2 }
|
||
|
||
wtWebGraphThermoBaroGraphicsBaseHeight OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Definiert die H<>he der Grafik in Pixeln."
|
||
::= { wtWebGraphThermoBaroGraphicsBase 3 }
|
||
|
||
wtWebGraphThermoBaroGraphicsBaseFrameColor OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(3))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Farbe des Rahmens in der grafischen Darstellung."
|
||
::= { wtWebGraphThermoBaroGraphicsBase 4 }
|
||
|
||
wtWebGraphThermoBaroGraphicsBaseBackgroundColor OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(3))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Farbe der Hintergrundfarbe in der grafischen Darstellung."
|
||
::= { wtWebGraphThermoBaroGraphicsBase 5 }
|
||
|
||
wtWebGraphThermoBaroGraphicsBasePollingrate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Definiert die Abfragerate in Sekunden,
|
||
mit der die Grafik aktualisiert wird."
|
||
::= { wtWebGraphThermoBaroGraphicsBase 6 }
|
||
|
||
-- wtWebGraphThermoBaroGraphicsSelect Group
|
||
----------------------------
|
||
|
||
wtWebGraphThermoBaroGraphicsSelectDisplaySensorSel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Die hier ausgew<65>hlten Sensoren werden grafisch angezeigt:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0: Sensor 1
|
||
Bit 1: Sensor 2
|
||
Bit 2: Sensor 3
|
||
Bit 3-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroGraphicsSelect 1 }
|
||
|
||
wtWebGraphThermoBaroGraphicsSelectDisplayShowExtrem OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Die Anzeige von Minima und Maxima der hier ausgew<65>hlten Sensoren
|
||
wird freigeschaltet:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0: Sensor 1
|
||
Bit 1: Sensor 2
|
||
Bit 2: Sensor 3
|
||
Bit 3-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroGraphicsSelect 2 }
|
||
|
||
-- Graph Sensor Color Table
|
||
|
||
wtWebGraphThermoBaroSensorColorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebGraphThermoBaroSensorColorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Liste der Sensorfarben in der grafischen Darstellung."
|
||
::= { wtWebGraphThermoBaroGraphicsSelect 3 }
|
||
|
||
wtWebGraphThermoBaroSensorColorEntry OBJECT-TYPE
|
||
SYNTAX WtWebGraphThermoBaroSensorColorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Nummern der Sensoren."
|
||
INDEX { wtWebGraphThermoBaroSensorNo }
|
||
::= { wtWebGraphThermoBaroSensorColorTable 1 }
|
||
|
||
wtWebGraphThermoBaroSensorColorEntry ::= SEQUENCE {
|
||
wtWebGraphThermoBaroGraphicsSensorColor OCTET STRING,
|
||
wtWebGraphThermoBaroGraphicsSelectScale OCTET STRING
|
||
}
|
||
|
||
wtWebGraphThermoBaroGraphicsSensorColor OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(3))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Farbe des Sensors in der grafischen Darstellung."
|
||
::= { wtWebGraphThermoBaroSensorColorEntry 1 }
|
||
|
||
wtWebGraphThermoBaroGraphicsSelectScale OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Zuweisung einer Skalierung zu einem Sensor:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0 : Use Scale 1
|
||
Bit 1 : Use Scale 2
|
||
Bit 2 : Use Scale 3
|
||
Bit 3-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroSensorColorEntry 2 }
|
||
|
||
-- wtWebGraphThermoBaroGraphicsScale Group
|
||
----------------------------
|
||
|
||
wtWebGraphThermoBaroGraphicsScaleAutoScaleEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"W<>hlt den Auto Scale Modus f<>r die jeweilige Skalierung aus:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0 : Scale 1 Auto scale enable
|
||
Bit 1 : Scale 2 Auto scale enable
|
||
Bit 2 : Scale 3 Auto scale enable
|
||
Bit 3-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroGraphicsScale 1 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScaleAutoFitEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"W<>hlt den Auto Fit Modus f<>r die jeweilige Skalierung aus:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0 : Scale 1 Auto fit enable
|
||
Bit 1 : Scale 2 Auto fit enable
|
||
Bit 2 : Scale 3 Auto fit enable
|
||
Bit 3-7: ungenutzt"
|
||
::= { wtWebGraphThermoBaroGraphicsScale 2 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale1Min OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 1: Minimum."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 3 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale2Min OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 2: Minimum."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 4 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale3Min OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 3: Minimum."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 5 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale4Min OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 4: Minimum."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 6 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale1Max OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 1: Maximum."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 7 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale2Max OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 2: Maximum."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 8 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale3Max OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 3: Maximum."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 9 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale4Max OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 4: Maximum."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 10 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale1Unit OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 1: Einheit."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 11 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale2Unit OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 2: Einheit."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 12 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale3Unit OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 3: Einheit."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 13 }
|
||
|
||
wtWebGraphThermoBaroGraphicsScale4Unit OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Skalierung 4: Einheit."
|
||
::= { wtWebGraphThermoBaroGraphicsScale 14 }
|
||
|
||
|
||
-- wtWebGraphThermoBaroPorts Group
|
||
----------------------------
|
||
|
||
-- Table
|
||
|
||
wtWebGraphThermoBaroPortTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebGraphThermoBaroPortEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Liste der Einstellungen abh<62>ngig von der Sensornummer."
|
||
::= { wtWebGraphThermoBaroPorts 1 }
|
||
|
||
wtWebGraphThermoBaroPortEntry OBJECT-TYPE
|
||
SYNTAX WtWebGraphThermoBaroPortEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Sensor-Parameter der einzelnen Sensoren."
|
||
INDEX { wtWebGraphThermoBaroSensorNo }
|
||
::= { wtWebGraphThermoBaroPortTable 1 }
|
||
|
||
WtWebGraphThermoBaroPortEntry ::= SEQUENCE {
|
||
wtWebGraphThermoBaroPortName OCTET STRING,
|
||
wtWebGraphThermoBaroPortText OCTET STRING,
|
||
wtWebGraphThermoBaroPortOffset1 OCTET STRING,
|
||
wtWebGraphThermoBaroPortTemperature1 OCTET STRING,
|
||
wtWebGraphThermoBaroPortOffset2 OCTET STRING,
|
||
wtWebGraphThermoBaroPortTemperature2 OCTET STRING,
|
||
wtWebGraphThermoBaroPortComment OCTET STRING,
|
||
wtWebGraphThermoBaroPortSensorSelect OCTET STRING
|
||
}
|
||
|
||
wtWebGraphThermoBaroPortName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name des Sensors."
|
||
::= { wtWebGraphThermoBaroPortEntry 1 }
|
||
|
||
wtWebGraphThermoBaroPortText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Beschreibung des Sensors."
|
||
::= { wtWebGraphThermoBaroPortEntry 2 }
|
||
|
||
wtWebGraphThermoBaroPortOffset1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 1."
|
||
::= { wtWebGraphThermoBaroPortEntry 3 }
|
||
|
||
wtWebGraphThermoBaroPortTemperature1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset-Kalibrierung: Referenztemperatur 1 in Grad mit max. 2 Nachkommastellen."
|
||
::= { wtWebGraphThermoBaroPortEntry 4 }
|
||
|
||
wtWebGraphThermoBaroPortOffset2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 2."
|
||
::= { wtWebGraphThermoBaroPortEntry 5 }
|
||
|
||
wtWebGraphThermoBaroPortTemperature2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset-Kalibrierung: Referenztemperatur 2 in Grad mit max. 2 Nachkommastellen."
|
||
::= { wtWebGraphThermoBaroPortEntry 6 }
|
||
|
||
wtWebGraphThermoBaroPortComment OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset-Kalibrierung: Angaben zu Datum, Referenzger<65>t, Operator."
|
||
::= { wtWebGraphThermoBaroPortEntry 7 }
|
||
|
||
wtWebGraphThermoBaroPortAltidude OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"H<>he des Sensors <20>ber Meeresh<73>he (<28>NN)."
|
||
::= { wtWebGraphThermoBaroPorts 2 }
|
||
|
||
-- wtWebGraphThermoBaroManufact Group
|
||
----------------------------
|
||
|
||
wtWebGraphThermoBaroMfName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Hersteller Firmenname"
|
||
::= { wtWebGraphThermoBaroManufact 1 }
|
||
|
||
wtWebGraphThermoBaroMfAddr OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Adresse des Herstellers."
|
||
::= { wtWebGraphThermoBaroManufact 2 }
|
||
|
||
wtWebGraphThermoBaroMfHotline OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Hotline des Herstellers."
|
||
::= { wtWebGraphThermoBaroManufact 3 }
|
||
|
||
wtWebGraphThermoBaroMfInternet OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Internet-Adresse des Herstellers."
|
||
::= { wtWebGraphThermoBaroManufact 4 }
|
||
|
||
wtWebGraphThermoBaroMfDeviceTyp OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Ger<65>tebezeichnung (Typ) des Herstellers."
|
||
::= { wtWebGraphThermoBaroManufact 5 }
|
||
|
||
wtWebGraphThermoBaroMfOrderNo OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bestellnummer des Ger<65>tes des Herstellers."
|
||
::= { wtWebGraphThermoBaroManufact 6 }
|
||
|
||
-- wtWebGraphThermoBaroDiag Group
|
||
----------------------------
|
||
|
||
wtWebGraphThermoBaroDiagErrorCount OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Anzahl der Eintr<74>ge im Fehlerspeicher."
|
||
::= { wtWebGraphThermoBaroDiag 1 }
|
||
|
||
wtWebGraphThermoBaroDiagBinaryError OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bitweise kodierte Fehlerursachen."
|
||
::= { wtWebGraphThermoBaroDiag 2 }
|
||
|
||
wtWebGraphThermoBaroDiagErrorIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Der Wert dieser Variable wird als Index f<>r die Ausgabe
|
||
eines Fehlertextes (wtWebGraphThermoBaroDiagErrorMessage) verwendet.
|
||
Die Fehler im Speicher sind von 1 bis wtWebGraphThermoBaroDiagErrorCount durchnummeriert.
|
||
Nach dem Schreiben einens g<>ltigen Wertes in diese Variable kann der dazugeh<65>rige Text
|
||
in wtWebGraphThermoBaroDiagErrorMessage ausgelesen werden."
|
||
::= { wtWebGraphThermoBaroDiag 3 }
|
||
|
||
wtWebGraphThermoBaroDiagErrorMessage OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Abh<62>ngig vom Wert wtWebGraphThermoBaroDiagErrorIndex wird ein Fehlertext angezeigt."
|
||
::= { wtWebGraphThermoBaroDiag 4 }
|
||
|
||
wtWebGraphThermoBaroDiagErrorClear OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Durch Schreiben eine 1 in diese Variable, wird der Fehlerspeicher gel<65>scht."
|
||
::= { wtWebGraphThermoBaroDiag 5 }
|
||
|
||
-- TRAP DEFINITIONS
|
||
|
||
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
||
|
||
wtWebGraphThermoBaroAlert1 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 1 ausgel<65>st wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Alarm 1"
|
||
--#SUMMARY "Alarm 1: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 31
|
||
|
||
wtWebGraphThermoBaroAlert2 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 2 ausgel<65>st wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Alarm 2"
|
||
--#SUMMARY "Alarm 2: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 32
|
||
|
||
wtWebGraphThermoBaroAlert3 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 3 ausgel<65>st wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Alarm 3"
|
||
--#SUMMARY "Alarm 3: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 33
|
||
|
||
wtWebGraphThermoBaroAlert4 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 4 ausgel<65>st wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Alarm 4"
|
||
--#SUMMARY "Alarm 4: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 34
|
||
|
||
wtWebGraphThermoBaroAlert5 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 5 ausgel<65>st wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Alarm 5"
|
||
--#SUMMARY "Alarm 5: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 35
|
||
|
||
wtWebGraphThermoBaroAlert6 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 6 ausgel<65>st wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Alarm 6"
|
||
--#SUMMARY "Alarm 6: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 36
|
||
|
||
wtWebGraphThermoBaroAlert7 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 7 ausgel<65>st wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Alarm 7"
|
||
--#SUMMARY "Alarm 7: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 37
|
||
|
||
wtWebGraphThermoBaroAlert8 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 8 ausgel<65>st wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Alarm 8"
|
||
--#SUMMARY "Alarm 8: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 38
|
||
|
||
wtWebGraphThermoBaroAlert9 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 1 gel<65>scht wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Release Alarm 1"
|
||
--#SUMMARY "Release Alarm 1: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 91
|
||
|
||
wtWebGraphThermoBaroAlert10 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 2 gel<65>scht wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Release Alarm 2"
|
||
--#SUMMARY "Release Alarm 2: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 92
|
||
|
||
wtWebGraphThermoBaroAlert11 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 3 gel<65>scht wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Release Alarm 3"
|
||
--#SUMMARY "Release Alarm 3: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 93
|
||
|
||
wtWebGraphThermoBaroAlert12 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 4 gel<65>scht wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Release Alarm 4"
|
||
--#SUMMARY "Release Alarm 4: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 94
|
||
|
||
wtWebGraphThermoBaroAlert13 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 5 gel<65>scht wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Release Alarm 5"
|
||
--#SUMMARY "Release Alarm 5: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 95
|
||
|
||
wtWebGraphThermoBaroAlert14 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 6 gel<65>scht wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Release Alarm 6"
|
||
--#SUMMARY "Release Alarm 6: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 96
|
||
|
||
wtWebGraphThermoBaroAlert15 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 7 gel<65>scht wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Release Alarm 7"
|
||
--#SUMMARY "Release Alarm 7: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 97
|
||
|
||
wtWebGraphThermoBaroAlert16 TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES { wtWebGraphThermoBaroAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn der Alarm 8 gel<65>scht wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Release Alarm 8"
|
||
--#SUMMARY "Release Alarm 8: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 98
|
||
|
||
wtWebGraphThermoBaroAlertDiag TRAP-TYPE
|
||
ENTERPRISE wtWebGraphThermoBaro
|
||
VARIABLES {
|
||
wtWebGraphThermoBaroDiagErrorIndex,
|
||
wtWebGraphThermoBaroDiagErrorMessage
|
||
}
|
||
DESCRIPTION
|
||
"Dieser SNMP-Trap wird generiert, wenn eine Diagnose/Error-Message ausgel<65>st wurde,
|
||
das SNMP-Trap-Enable gesetzt ist und
|
||
SNMP in Enable freigegeben ist."
|
||
-- NMS trap annotation
|
||
--#TYPE "Thermo-Hygrometer Diagnose Error"
|
||
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
||
--#ARGUMENTS {0,1}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
::= 110
|
||
|
||
END
|