- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
2360 lines
68 KiB
Text
2360 lines
68 KiB
Text
WebGraph-8xThermometer-US-MIB DEFINITIONS ::= BEGIN
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.30
|
||
----------------------------------------------------------------
|
||
-- 22.06.2010 Output with decimal point
|
||
--
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.29
|
||
----------------------------------------------------------------
|
||
-- 12.01.2009 Webio
|
||
-- Trap number
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.28
|
||
----------------------------------------------------------------
|
||
-- 19.01.2007 Webio
|
||
-- New Graphics java script base parameter
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.27
|
||
----------------------------------------------------------------
|
||
-- 09.11.2006 Webio
|
||
-- DHCP enable
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.25
|
||
----------------------------------------------------------------
|
||
-- 28.06.2006 New: Community String Trap
|
||
--
|
||
----------------------------------------------------------------
|
||
-- Revison: 1.24
|
||
----------------------------------------------------------------
|
||
-- 23.12.2005 #5760x, WebGraph 8x Thermometer
|
||
--
|
||
|
||
|
||
IMPORTS
|
||
|
||
OBJECT-TYPE FROM RFC-1212
|
||
TRAP-TYPE FROM RFC-1215
|
||
DisplayString, PhysAddress FROM RFC1213-MIB
|
||
enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
|
||
|
||
|
||
-- IpAddress ::=
|
||
-- [APPLICATION 0]
|
||
-- IMPLICIT OCTET STRING (SIZE (4))
|
||
-- Counter ::=
|
||
-- [APPLICATION 1]
|
||
-- IMPLICIT INTEGER (0..4294967295)
|
||
-- Gauge ::=
|
||
-- [APPLICATION 2]
|
||
-- IMPLICIT INTEGER (0..4294967295)
|
||
-- TimeTicks ::=
|
||
-- [APPLICATION 3]
|
||
-- IMPLICIT INTEGER (0..4294967295)
|
||
|
||
|
||
-- DisplayString ::= OCTET STRING
|
||
-- PhysAddress ::= OCTET STRING
|
||
|
||
-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
|
||
-- privat OBJECT IDENTIFIER ::= { internet 4 }
|
||
-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
|
||
|
||
|
||
|
||
-- Wiesemann & Theis Com-Server MIB
|
||
|
||
wut OBJECT IDENTIFIER ::= { enterprises 5040 }
|
||
wtComServer OBJECT IDENTIFIER ::= { wut 1 }
|
||
wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
|
||
|
||
-- wtWebio Tree
|
||
|
||
wtWebioAn8Graph OBJECT IDENTIFIER ::= { wtWebio 6 }
|
||
|
||
-- wtWebioAn8Graph Tree
|
||
|
||
wtWebioAn8GraphTemp OBJECT IDENTIFIER ::= { wtWebioAn8Graph 1 }
|
||
wtWebioAn8GraphSessCntrl OBJECT IDENTIFIER ::= { wtWebioAn8Graph 2 }
|
||
wtWebioAn8GraphConfig OBJECT IDENTIFIER ::= { wtWebioAn8Graph 3 }
|
||
wtWebioAn8GraphDiag OBJECT IDENTIFIER ::= { wtWebioAn8Graph 4 }
|
||
|
||
-- wtWebioAn8GraphConfig Tree
|
||
|
||
wtWebioAn8GraphDevice OBJECT IDENTIFIER ::= { wtWebioAn8GraphConfig 1 }
|
||
wtWebioAn8GraphPorts OBJECT IDENTIFIER ::= { wtWebioAn8GraphConfig 2 }
|
||
wtWebioAn8GraphManufact OBJECT IDENTIFIER ::= { wtWebioAn8GraphConfig 3 }
|
||
|
||
-- wtWebioAn8GraphDevice Tree
|
||
|
||
wtWebioAn8GraphText OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 1 }
|
||
wtWebioAn8GraphTimeDate OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 2 }
|
||
wtWebioAn8GraphBasic OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 3 }
|
||
wtWebioAn8GraphDatalogger OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 4 }
|
||
wtWebioAn8GraphAlarm OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 5 }
|
||
wtWebioAn8GraphGraphics OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 6 }
|
||
|
||
-- wtWebioAn8GraphTimeDate Tree
|
||
|
||
wtWebioAn8GraphTimeZone OBJECT IDENTIFIER ::= { wtWebioAn8GraphTimeDate 1 }
|
||
wtWebioAn8GraphTimeServer OBJECT IDENTIFIER ::= { wtWebioAn8GraphTimeDate 2 }
|
||
wtWebioAn8GraphDeviceClock OBJECT IDENTIFIER ::= { wtWebioAn8GraphTimeDate 3 }
|
||
|
||
-- wtWebioAn8GraphBasic Tree
|
||
|
||
wtWebioAn8GraphNetwork OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 1 }
|
||
wtWebioAn8GraphHTTP OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 2 }
|
||
wtWebioAn8GraphMail OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 3 }
|
||
wtWebioAn8GraphSNMP OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 4 }
|
||
wtWebioAn8GraphUDP OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 5 }
|
||
wtWebioAn8GraphSyslog OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 6 }
|
||
wtWebioAn8GraphFTP OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 7 }
|
||
|
||
-- wtWebioAn8GraphGraphics Tree
|
||
|
||
wtWebioAn8GraphGraphicsBase OBJECT IDENTIFIER ::= { wtWebioAn8GraphGraphics 1 }
|
||
wtWebioAn8GraphGraphicsSelect OBJECT IDENTIFIER ::= { wtWebioAn8GraphGraphics 2 }
|
||
wtWebioAn8GraphGraphicsScale OBJECT IDENTIFIER ::= { wtWebioAn8GraphGraphics 3 }
|
||
|
||
|
||
-- wtWebioAn8GraphTemp Group
|
||
------------------------
|
||
|
||
wtWebioAn8GraphSensors OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Number of temperature sensors"
|
||
::= { wtWebioAn8GraphTemp 1 }
|
||
|
||
-- Interface Table
|
||
|
||
wtWebioAn8GraphSensorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebioAn8GraphSensorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"List of sensors."
|
||
::= { wtWebioAn8GraphTemp 2 }
|
||
|
||
wtWebioAn8GraphSensorEntry OBJECT-TYPE
|
||
SYNTAX WtWebioAn8GraphSensorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Temperature sensor numbers."
|
||
INDEX { wtWebioAn8GraphSensorNo }
|
||
::= { wtWebioAn8GraphSensorTable 1 }
|
||
|
||
WtWebioAn8GraphSensorEntry ::= SEQUENCE {
|
||
wtWebioAn8GraphSensorNo INTEGER
|
||
}
|
||
|
||
wtWebioAn8GraphSensorNo OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Temperature sensor number."
|
||
::= { wtWebioAn8GraphSensorEntry 1 }
|
||
|
||
|
||
-- wtWebioAn8GraphTempValue Table
|
||
|
||
wtWebioAn8GraphTempValueTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebioAn8GraphTempValueEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"List of temperature values corresponding to the channel numbers."
|
||
::= { wtWebioAn8GraphTemp 3 }
|
||
|
||
wtWebioAn8GraphTempValueEntry OBJECT-TYPE
|
||
SYNTAX WtWebioAn8GraphTempValueEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Temperatures of the sensors."
|
||
INDEX { wtWebioAn8GraphSensorNo }
|
||
::= { wtWebioAn8GraphTempValueTable 1 }
|
||
|
||
WtWebioAn8GraphTempValueEntry ::= SEQUENCE{
|
||
wtWebioAn8GraphTempValue OCTET STRING
|
||
}
|
||
|
||
wtWebioAn8GraphTempValue OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (5))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Temperature value of the sensor, ASCII, 5 characters in length."
|
||
::= { wtWebioAn8GraphTempValueEntry 1 }
|
||
|
||
-- wtWebioAn8GraphBinaryTempValue Table
|
||
|
||
wtWebioAn8GraphBinaryTempValueTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebioAn8GraphBinaryTempValueEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"List of binary temperature values corresponding to the channel numbers."
|
||
::= { wtWebioAn8GraphTemp 4 }
|
||
|
||
wtWebioAn8GraphBinaryTempValueEntry OBJECT-TYPE
|
||
SYNTAX WtWebioAn8GraphBinaryTempValueEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary temperature values of the sensors."
|
||
INDEX { wtWebioAn8GraphSensorNo }
|
||
::= { wtWebioAn8GraphBinaryTempValueTable 1 }
|
||
|
||
WtWebioAn8GraphBinaryTempValueEntry ::= SEQUENCE{
|
||
wtWebioAn8GraphBinaryTempValue INTEGER
|
||
}
|
||
|
||
wtWebioAn8GraphBinaryTempValue OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary temperature value of the sensor in 1/10 degrees Celsius,
|
||
signed number, 0x4FFF6 indicates an
|
||
invalid measured value."
|
||
::= { wtWebioAn8GraphBinaryTempValueEntry 1 }
|
||
|
||
-- wtWebioAn8GraphTempValuePkt Table
|
||
|
||
wtWebioAn8GraphTempValuePktTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebioAn8GraphTempValuePktEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"List of temperature values corresponding to the channel numbers."
|
||
::= { wtWebioAn8GraphTemp 8 }
|
||
|
||
wtWebioAn8GraphTempValuePktEntry OBJECT-TYPE
|
||
SYNTAX WtWebioAn8GraphTempValuePktEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Temperatures of the sensors."
|
||
INDEX { wtWebioAn8GraphSensorNo }
|
||
::= { wtWebioAn8GraphTempValuePktTable 1 }
|
||
|
||
WtWebioAn8GraphTempValuePktEntry ::= SEQUENCE{
|
||
wtWebioAn8GraphTempValuePkt OCTET STRING
|
||
}
|
||
|
||
wtWebioAn8GraphTempValuePkt OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (5))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Temperature value of the sensor, ASCII, 5 characters in length, decimal point."
|
||
::= { wtWebioAn8GraphTempValuePktEntry 1 }
|
||
|
||
-- wtWebioAn8GraphSessCntrl Group
|
||
--------------------------------
|
||
|
||
wtWebioAn8GraphSessCntrlPassword OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Entering this password opens a session which is ended by writing a 1 to
|
||
wtWebioAn8GraphSessCntrlLogout. When read this variable provides a string of
|
||
length zero."
|
||
::= { wtWebioAn8GraphSessCntrl 1 }
|
||
|
||
wtWebioAn8GraphSessCntrlConfigMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebioAn8GraphSessCntrl-NoSession(0),
|
||
wtWebioAn8GraphSessCntrl-Session(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When the device is in SNMP configuration mode, the value 1 is
|
||
returned, otherwise 0. If the read value is 0 even though the
|
||
password was written, the device is already in config mode and the
|
||
variables can only be read."
|
||
::= { wtWebioAn8GraphSessCntrl 2 }
|
||
|
||
wtWebioAn8GraphSessCntrlLogout OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"If the device is in configuration mode and the session was opened by
|
||
this SNMP Manager, writing a 1 to this variable will end the session
|
||
and all parameters are stored.
|
||
Writing a 2 discards all entries again.
|
||
When read this variable provides the value 0."
|
||
::= { wtWebioAn8GraphSessCntrl 3 }
|
||
|
||
wtWebioAn8GraphSessCntrlAdminPassword OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This password protects access to the variables with administrator rights.
|
||
It can only be changed by the administrator. If no password was assigned,
|
||
the valid password is public."
|
||
::= { wtWebioAn8GraphSessCntrl 4 }
|
||
|
||
wtWebioAn8GraphSessCntrlConfigPassword OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This password protects access to the variables with configurator rights. It can
|
||
be changed by the administrator and by the configurator. If no password was assigned,
|
||
the valid password is public. When read this variable provides a null-pointer."
|
||
::= { wtWebioAn8GraphSessCntrl 5 }
|
||
|
||
|
||
-- wtWebioAn8GraphText Group
|
||
------------------------
|
||
|
||
wtWebioAn8GraphDeviceName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name of the Webio, which is user definable."
|
||
::= { wtWebioAn8GraphText 1 }
|
||
|
||
wtWebioAn8GraphDeviceText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Description of the Webio, which is user definable."
|
||
::= { wtWebioAn8GraphText 2 }
|
||
|
||
wtWebioAn8GraphDeviceLocation OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Description of the location of the Webio, which is user definable."
|
||
::= { wtWebioAn8GraphText 3 }
|
||
|
||
wtWebioAn8GraphDeviceContact OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Contact address of the system operator of the Webio, which is user definable."
|
||
::= { wtWebioAn8GraphText 4 }
|
||
|
||
-- wtWebioAn8GraphTimeZone Group
|
||
----------------------------
|
||
|
||
wtWebioAn8GraphTzOffsetHrs OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset hours for the time zone (winter time) with respect to UTC."
|
||
::= { wtWebioAn8GraphTimeZone 1 }
|
||
|
||
wtWebioAn8GraphTzOffsetMin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset minutes for the time zone (winter time) with respect to UTC."
|
||
::= { wtWebioAn8GraphTimeZone 2 }
|
||
|
||
wtWebioAn8GraphTzEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded conditions:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1-7: unused
|
||
Bit 0 : Apply Timezone"
|
||
::= { wtWebioAn8GraphTimeZone 3 }
|
||
|
||
wtWebioAn8GraphStTzOffsetHrs OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset hours of the time zone (summer time) with respect to UTC."
|
||
::= { wtWebioAn8GraphTimeZone 4 }
|
||
|
||
wtWebioAn8GraphStTzOffsetMin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset minutes of the time zone (summer time) with respect to UTC."
|
||
::= { wtWebioAn8GraphTimeZone 5 }
|
||
|
||
wtWebioAn8GraphStTzEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded conditions:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1-7: unused
|
||
Bit 0 : Apply Summertime"
|
||
::= { wtWebioAn8GraphTimeZone 6 }
|
||
|
||
wtWebioAn8GraphStTzStartMonth OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebioAn8GraphStartMonth-January(1),
|
||
wtWebioAn8GraphStartMonth-February(2),
|
||
wtWebioAn8GraphStartMonth-March(3),
|
||
wtWebioAn8GraphStartMonth-April(4),
|
||
wtWebioAn8GraphStartMonth-May(5),
|
||
wtWebioAn8GraphStartMonth-June(6),
|
||
wtWebioAn8GraphStartMonth-July(7),
|
||
wtWebioAn8GraphStartMonth-August(8),
|
||
wtWebioAn8GraphStartMonth-September(9),
|
||
wtWebioAn8GraphStartMonth-October(10),
|
||
wtWebioAn8GraphStartMonth-November(11),
|
||
wtWebioAn8GraphStartMonth-December(12)
|
||
}
|
||
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Month in which the change is made from winter time to summer time."
|
||
::= { wtWebioAn8GraphTimeZone 7 }
|
||
|
||
wtWebioAn8GraphStTzStartMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebioAn8GraphStartMode-first(1),
|
||
wtWebioAn8GraphStartMode-second(2),
|
||
wtWebioAn8GraphStartMode-third(3),
|
||
wtWebioAn8GraphStartMode-fourth(4),
|
||
wtWebioAn8GraphStartMode-last(5)
|
||
}
|
||
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Mode of the day of the week for which the change is made from winter time to summer time."
|
||
::= { wtWebioAn8GraphTimeZone 8 }
|
||
|
||
wtWebioAn8GraphStTzStartWday OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebioAn8GraphStartWday-Sunday(1),
|
||
wtWebioAn8GraphStartWday-Monday(2),
|
||
wtWebioAn8GraphStartWday-Tuesday(3),
|
||
wtWebioAn8GraphStartWday-Thursday(4),
|
||
wtWebioAn8GraphStartWday-Wednesday(5),
|
||
wtWebioAn8GraphStartWday-Friday(6),
|
||
wtWebioAn8GraphStartWday-Saturday(7)
|
||
}
|
||
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Day of the week on which the change is made from winter time to summer time"
|
||
::= { wtWebioAn8GraphTimeZone 9 }
|
||
|
||
wtWebioAn8GraphStTzStartHrs OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Hour in which the time zone is changed from winter to summer time with
|
||
respect to UTC."
|
||
::= { wtWebioAn8GraphTimeZone 10 }
|
||
|
||
wtWebioAn8GraphStTzStartMin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Minute in which the time zone is changed from winter to summer time with
|
||
respect to UTC."
|
||
::= { wtWebioAn8GraphTimeZone 11 }
|
||
|
||
wtWebioAn8GraphStTzStopMonth OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebioAn8GraphStopMonth-January(1),
|
||
wtWebioAn8GraphStopMonth-February(2),
|
||
wtWebioAn8GraphStopMonth-March(3),
|
||
wtWebioAn8GraphStopMonth-April(4),
|
||
wtWebioAn8GraphStopMonth-May(5),
|
||
wtWebioAn8GraphStopMonth-June(6),
|
||
wtWebioAn8GraphStopMonth-July(7),
|
||
wtWebioAn8GraphStopMonth-August(8),
|
||
wtWebioAn8GraphStopMonth-September(9),
|
||
wtWebioAn8GraphStopMonth-October(10),
|
||
wtWebioAn8GraphStopMonth-November(11),
|
||
wtWebioAn8GraphStopMonth-December(12)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Month in which the change is made from summer time to winter time."
|
||
::= { wtWebioAn8GraphTimeZone 12 }
|
||
|
||
wtWebioAn8GraphStTzStopMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebioAn8GraphStopMode-first(1),
|
||
wtWebioAn8GraphStopMode-second(2),
|
||
wtWebioAn8GraphStopMode-third(3),
|
||
wtWebioAn8GraphStopMode-fourth(4),
|
||
wtWebioAn8GraphStopMode-last(5)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Mode of the week day on which the change is made from summer time to winter time."
|
||
::= { wtWebioAn8GraphTimeZone 13 }
|
||
|
||
wtWebioAn8GraphStTzStopWday OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebioAn8GraphStopWday-Sunday(1),
|
||
wtWebioAn8GraphStopWday-Monday(2),
|
||
wtWebioAn8GraphStopWday-Tuesday(3),
|
||
wtWebioAn8GraphStopWday-Thursday(4),
|
||
wtWebioAn8GraphStopWday-Wednesday(5),
|
||
wtWebioAn8GraphStopWday-Friday(6),
|
||
wtWebioAn8GraphStopWday-Saturday(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Day of the week on which the change is made from summer time to winter time."
|
||
::= { wtWebioAn8GraphTimeZone 14 }
|
||
|
||
wtWebioAn8GraphStTzStopHrs OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Hour at which the time zone is changed from summer to winter time with
|
||
respect to UTC."
|
||
::= { wtWebioAn8GraphTimeZone 15 }
|
||
|
||
wtWebioAn8GraphStTzStopMin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Minute at which the time zone is changed from summer to winter time with
|
||
respect to UTC."
|
||
::= { wtWebioAn8GraphTimeZone 16 }
|
||
|
||
-- wtWebioAn8GraphTimeServer Group
|
||
----------------------------
|
||
|
||
wtWebioAn8GraphTimeServer1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP address or name of the 1st time server in ASCII"
|
||
::= { wtWebioAn8GraphTimeServer 1 }
|
||
|
||
wtWebioAn8GraphTimeServer2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP address or name of the 2nd time server in ASCII"
|
||
::= { wtWebioAn8GraphTimeServer 2 }
|
||
|
||
wtWebioAn8GraphTsEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded conditions:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1-7: unused
|
||
Bit 0 : Apply Time Server"
|
||
::= { wtWebioAn8GraphTimeServer 3 }
|
||
|
||
wtWebioAn8GraphTsSyncTime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Daily synchronisation time with the time server (hour: 0-23)."
|
||
::= { wtWebioAn8GraphTimeServer 4 }
|
||
|
||
-- wtWebioAn8GraphDeviceClock Group
|
||
----------------------------
|
||
|
||
wtWebioAn8GraphClockHrs OBJECT-TYPE
|
||
SYNTAX INTEGER (0..23)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Clock hours taking into account the time zone settings."
|
||
::= { wtWebioAn8GraphDeviceClock 1 }
|
||
|
||
wtWebioAn8GraphClockMin OBJECT-TYPE
|
||
SYNTAX INTEGER (0..59)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Clock minutes taking into account the time zone settings."
|
||
::= { wtWebioAn8GraphDeviceClock 2 }
|
||
|
||
wtWebioAn8GraphClockDay OBJECT-TYPE
|
||
SYNTAX INTEGER (1..31)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Date: Day of the month, taking into account the time zone settings."
|
||
::= { wtWebioAn8GraphDeviceClock 3 }
|
||
|
||
wtWebioAn8GraphClockMonth OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebioAn8GraphClockMonth-January(1),
|
||
wtWebioAn8GraphClockMonth-February(2),
|
||
wtWebioAn8GraphClockMonth-March(3),
|
||
wtWebioAn8GraphClockMonth-April(4),
|
||
wtWebioAn8GraphClockMonth-May(5),
|
||
wtWebioAn8GraphClockMonth-June(6),
|
||
wtWebioAn8GraphClockMonth-July(7),
|
||
wtWebioAn8GraphClockMonth-August(8),
|
||
wtWebioAn8GraphClockMonth-September(9),
|
||
wtWebioAn8GraphClockMonth-October(10),
|
||
wtWebioAn8GraphClockMonth-November(11),
|
||
wtWebioAn8GraphClockMonth-December(12)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Date: Month, taking into account the time zone settings."
|
||
::= { wtWebioAn8GraphDeviceClock 4 }
|
||
|
||
wtWebioAn8GraphClockYear OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Date: Year, taking into account the time zone settings."
|
||
::= { wtWebioAn8GraphDeviceClock 5 }
|
||
|
||
|
||
-- wtWebioAn8GraphNetwork Group
|
||
------------------------
|
||
|
||
wtWebioAn8GraphIpAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP address of the Webio"
|
||
::= { wtWebioAn8GraphNetwork 1 }
|
||
|
||
wtWebioAn8GraphSubnetMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Subnet mask of the Webio"
|
||
::= { wtWebioAn8GraphNetwork 2 }
|
||
|
||
wtWebioAn8GraphGateway OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Gateway of the Webio"
|
||
::= { wtWebioAn8GraphNetwork 3 }
|
||
|
||
wtWebioAn8GraphDnsServer1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP address of the 1st DNS server in ASCII"
|
||
::= { wtWebioAn8GraphNetwork 4 }
|
||
|
||
wtWebioAn8GraphDnsServer2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP address of the 2nd DNS server in ASCII"
|
||
::= { wtWebioAn8GraphNetwork 5 }
|
||
|
||
wtWebioAn8GraphAddConfig OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Additional configuration (1=ON):
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0: BOOTP disable
|
||
Bit 1: DHCP disable
|
||
"
|
||
::= { wtWebioAn8GraphNetwork 6 }
|
||
|
||
-- wtWebioAn8GraphHTTP Group
|
||
--------------------------------
|
||
|
||
wtWebioAn8GraphStartup OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded start page:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1: Index.htm
|
||
Bit 2: Home.htm
|
||
Bit 3: User.htm
|
||
Only one page may be selected at a time."
|
||
::= { wtWebioAn8GraphHTTP 1 }
|
||
|
||
wtWebioAn8GraphGetHeaderEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"If these bits are set, every answer of a short form GET question will be lead
|
||
by the IP-address and name of the device and/or a HTTP header:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1-6: unused
|
||
Bit 1 : GET HTTP enable
|
||
Bit 0 : GET Header enable"
|
||
::= { wtWebioAn8GraphHTTP 2 }
|
||
|
||
wtWebioAn8GraphHttpPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Definition of the standard HTML port (Default: 80)."
|
||
::= { wtWebioAn8GraphHTTP 3 }
|
||
|
||
|
||
-- wtWebioAn8GraphMail Group
|
||
--------------------------------
|
||
|
||
wtWebioAn8GraphMailAdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Device name for mail administration."
|
||
::= { wtWebioAn8GraphMail 1 }
|
||
|
||
wtWebioAn8GraphMailReply OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Reply address for the mail server."
|
||
::= { wtWebioAn8GraphMail 2 }
|
||
|
||
wtWebioAn8GraphMailServer OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name or IP address of the mail server."
|
||
::= { wtWebioAn8GraphMail 3 }
|
||
|
||
wtWebioAn1MailEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Set this bit to enable the sending of mails:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1-7: unused
|
||
Bit 0 : Mail enable"
|
||
::= { wtWebioAn8GraphMail 4 }
|
||
|
||
wtWebioAn8GraphMailAuthentication OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Selection of the authentication modi:
|
||
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
||
Bit 0 corresponds to the LSB.
|
||
OCTET 1: unused
|
||
OCTET 2: unused
|
||
OCTET 3: unused
|
||
OCTET 4: Bit 3-7: unused
|
||
Bit 2 : POP3 before SMTP
|
||
Bit 1 : ESMTP, authentication
|
||
Bit 0 : SMTP, no authentication"
|
||
::= { wtWebioAn8GraphMail 5 }
|
||
|
||
wtWebioAn8GraphMailAuthUser OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name of the user to be authenticated."
|
||
::= { wtWebioAn8GraphMail 6 }
|
||
|
||
wtWebioAn8GraphMailAuthPassword OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Authentication password."
|
||
::= { wtWebioAn8GraphMail 7 }
|
||
|
||
wtWebioAn8GraphMailPop3Server OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name or Ip-address of the POP3 Servers."
|
||
::= { wtWebioAn8GraphMail 8 }
|
||
|
||
|
||
-- wtWebioAn8GraphSNMP Group
|
||
--------------------------------
|
||
|
||
wtWebioAn8GraphSnmpCommunityStringRead OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Community string read only"
|
||
::= { wtWebioAn8GraphSNMP 1 }
|
||
|
||
wtWebioAn8GraphSnmpCommunityStringReadWrite OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Community string read / write"
|
||
::= { wtWebioAn8GraphSNMP 2 }
|
||
|
||
wtWebioAn8GraphSystemTrapManagerIP OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name or IP address of the TCP server which accepts the system trap."
|
||
::= { wtWebioAn8GraphSNMP 3 }
|
||
|
||
wtWebioAn8GraphSystemTrapEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded trigger conditions:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0: ColdStart
|
||
Bit 1: WarmStart
|
||
Bit 2-7: unused"
|
||
::= { wtWebioAn8GraphSNMP 4 }
|
||
|
||
wtWebioAn8GraphSnmpEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Set bit 0 to enable SNMP.
|
||
If disabled, the device did not respond to any SNMP requests.
|
||
Bit 1 decided wether the community string of read operations
|
||
is compared with the system password or not:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1-7: unused
|
||
Bit 0 : SNMP enable"
|
||
::= { wtWebioAn8GraphSNMP 5 }
|
||
|
||
wtWebioAn8GraphSnmpCommunityStringTrap OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Community string send within traps."
|
||
::= { wtWebioAn8GraphSNMP 6 }
|
||
|
||
-- wtWebioAn8GraphUDP Group
|
||
--------------------------------
|
||
|
||
wtWebioAn8GraphUdpPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
||
port number must be unique within the device."
|
||
::= { wtWebioAn8GraphUDP 1 }
|
||
|
||
wtWebioAn8GraphUdpEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Set this bit to enable UDP support:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1-7: unused
|
||
Bit 0 : UDP enable"
|
||
::= { wtWebioAn8GraphUDP 2 }
|
||
|
||
|
||
-- wtWebioAn8GraphSyslog Group
|
||
--------------------------------
|
||
|
||
wtWebioAn8GraphSyslogServerIP OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
||
::= { wtWebioAn8GraphSyslog 1 }
|
||
|
||
wtWebioAn8GraphSyslogServerPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Portnumber of the Syslog servers, default 514."
|
||
::= { wtWebioAn8GraphSyslog 2 }
|
||
|
||
wtWebioAn8GraphSyslogSystemMessagesEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded trigger conditions:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0: ColdStart
|
||
Bit 1: WarmStart
|
||
Bit 2: Diag Messages
|
||
Bit 3-7: unused"
|
||
::= { wtWebioAn8GraphSyslog 3 }
|
||
|
||
wtWebioAn8GraphSyslogEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Set bit 0 to enable Syslog:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1-7: unused
|
||
Bit 0 : Syslog enable"
|
||
::= { wtWebioAn8GraphSyslog 4 }
|
||
|
||
-- wtWebioAn8GraphFTP Group
|
||
--------------------------------
|
||
|
||
wtWebioAn8GraphFTPServerIP OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name or IP address of the FTP server, which accepts the FTP messages."
|
||
::= { wtWebioAn8GraphFTP 1 }
|
||
|
||
wtWebioAn8GraphFTPServerControlPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Portnumber of the control port of the FTP server, default 21."
|
||
::= { wtWebioAn8GraphFTP 2 }
|
||
|
||
wtWebioAn8GraphFTPUserName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"FTP Loggin: user name."
|
||
::= { wtWebioAn8GraphFTP 3 }
|
||
|
||
wtWebioAn8GraphFTPPassword OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"FTP Loggin: user password."
|
||
::= { wtWebioAn8GraphFTP 4 }
|
||
|
||
wtWebioAn8GraphFTPAccount OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"FTP Loggin: name of account."
|
||
::= { wtWebioAn8GraphFTP 5 }
|
||
|
||
wtWebioAn8GraphFTPOption OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bit 0 switches the FTP Server in Passiv-Mode,
|
||
the Client controls the data connection on its own:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1-7: unused
|
||
Bit 0 : PASV enable"
|
||
::= { wtWebioAn8GraphFTP 6 }
|
||
|
||
wtWebioAn8GraphFTPEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Set Bit 0 to enable FTP:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1-7: unused
|
||
Bit 0 : FTP enable"
|
||
::= { wtWebioAn8GraphFTP 7 }
|
||
|
||
-- wtWebioAn8GraphDatalogger Group
|
||
--------------------------------
|
||
|
||
wtWebioAn8GraphLoggerTimebase OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebioAn8GraphDatalogger-1Min(1),
|
||
wtWebioAn8GraphDatalogger-5Min(2),
|
||
wtWebioAn8GraphDatalogger-15Min(3),
|
||
wtWebioAn8GraphDatalogger-60Min(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Time base of the data logger"
|
||
::= { wtWebioAn8GraphDatalogger 1 }
|
||
|
||
wtWebioAn8GraphLoggerSensorSel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded trigger conditions:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0: Sensor 1
|
||
Bit 1: Sensor 2
|
||
Bit 2: Sensor 3
|
||
Bit 3: Sensor 4
|
||
Bit 4: Sensor 5
|
||
Bit 5: Sensor 6
|
||
Bit 6: Sensor 7
|
||
Bit 7: Sensor 8"
|
||
::= { wtWebioAn8GraphDatalogger 2 }
|
||
|
||
wtWebioAn8GraphDisplaySensorSel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded sensor selection:
|
||
only selected sensors will be shown in the graphical presentation:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0: Sensor 1
|
||
Bit 1: Sensor 2
|
||
Bit 2: Sensor 3
|
||
Bit 3: Sensor 4
|
||
Bit 4: Sensor 5
|
||
Bit 5: Sensor 6
|
||
Bit 6: Sensor 7
|
||
Bit 7: Sensor 8"
|
||
::= { wtWebioAn8GraphDatalogger 3 }
|
||
|
||
-- Graph Sensor Color Table
|
||
|
||
wtWebioAn8GraphSensorColorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebioAn8GraphSensorColorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"List of sensor colors for the praphical presentation."
|
||
::= { wtWebioAn8GraphDatalogger 4 }
|
||
|
||
wtWebioAn8GraphSensorColorEntry OBJECT-TYPE
|
||
SYNTAX WtWebioAn8GraphSensorColorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Index numbers of the sensors."
|
||
INDEX { wtWebioAn8GraphSensorNo }
|
||
::= { wtWebioAn8GraphSensorColorTable 1 }
|
||
|
||
WtWebioAn8GraphSensorColorEntry ::= SEQUENCE {
|
||
wtWebioAn8GraphSensorColor OCTET STRING
|
||
}
|
||
|
||
wtWebioAn8GraphSensorColor OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(3))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Color of the sensors at the praphical presention."
|
||
::= { wtWebioAn8GraphSensorColorEntry 1 }
|
||
|
||
wtWebioAn8GraphAutoScaleEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"If bit 0 is set, vertical auto scale is enabled:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 1-7: unused
|
||
Bit 0 : Auto Scale enable"
|
||
::= { wtWebioAn8GraphDatalogger 5 }
|
||
|
||
wtWebioAn8GraphVerticalUpperLimit OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This value defines the maximum temperature shown in the graphical presentation,
|
||
if no auto scaling is selected.
|
||
Temperature in degrees with maximum 2 decimal places."
|
||
::= { wtWebioAn8GraphDatalogger 6 }
|
||
|
||
wtWebioAn8GraphVerticalLowerLimit OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This value defines the minimum temperature shown in the graphical presentation,
|
||
if no auto scaling is selected.
|
||
Temperature in degrees with maximum 2 decimal places."
|
||
::= { wtWebioAn8GraphDatalogger 7 }
|
||
|
||
wtWebioAn8GraphHorizontalZoom OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
wtWebioAn8GraphZoom-25min(1),
|
||
wtWebioAn8GraphZoom-75min(2),
|
||
wtWebioAn8GraphZoom-5hrs(3),
|
||
wtWebioAn8GraphZoom-30hrs(4),
|
||
wtWebioAn8GraphZoom-5days(5),
|
||
wtWebioAn8GraphZoom-25days(6)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Defines the default zoom stage, if no auto scaling is selected."
|
||
::= { wtWebioAn8GraphDatalogger 8 }
|
||
|
||
-- wtWebioAn8GraphAlarm Group
|
||
----------------------------
|
||
|
||
wtWebioAn8GraphAlarmCount OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Number of independent alarms."
|
||
::= { wtWebioAn8GraphAlarm 1 }
|
||
|
||
-- Alarm Interface Table
|
||
|
||
wtWebioAn8GraphAlarmIfTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebioAn8GraphAlarmIfEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"List of alarm indices."
|
||
::= { wtWebioAn8GraphAlarm 2 }
|
||
|
||
wtWebioAn8GraphAlarmIfEntry OBJECT-TYPE
|
||
SYNTAX WtWebioAn8GraphAlarmIfEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Numbers of the alarms."
|
||
INDEX { wtWebioAn8GraphAlarmNo }
|
||
::= { wtWebioAn8GraphAlarmIfTable 1 }
|
||
|
||
WtWebioAn8GraphAlarmIfEntry ::= SEQUENCE {
|
||
wtWebioAn8GraphAlarmNo INTEGER
|
||
}
|
||
|
||
wtWebioAn8GraphAlarmNo OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm number."
|
||
::= { wtWebioAn8GraphAlarmIfEntry 1 }
|
||
|
||
-- Alarm Table
|
||
|
||
wtWebioAn8GraphAlarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebioAn8GraphAlarmEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"List of settings depending on the alarm number."
|
||
::= { wtWebioAn8GraphAlarm 3 }
|
||
|
||
wtWebioAn8GraphAlarmEntry OBJECT-TYPE
|
||
SYNTAX WtWebioAn8GraphAlarmEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm parameters of the individual alarms."
|
||
INDEX { wtWebioAn8GraphAlarmNo }
|
||
::= { wtWebioAn8GraphAlarmTable 1 }
|
||
|
||
WtWebioAn8GraphAlarmEntry ::= SEQUENCE {
|
||
wtWebioAn8GraphAlarmTrigger OCTET STRING,
|
||
wtWebioAn8GraphAlarmMin OCTET STRING,
|
||
wtWebioAn8GraphAlarmMax OCTET STRING,
|
||
wtWebioAn8GraphAlarmHysteresis OCTET STRING,
|
||
wtWebioAn8GraphAlarmDelay OCTET STRING,
|
||
wtWebioAn8GraphAlarmInterval OCTET STRING,
|
||
wtWebioAn8GraphAlarmEnable OCTET STRING,
|
||
wtWebioAn8GraphAlarmEMailAddr OCTET STRING,
|
||
wtWebioAn8GraphAlarmMailSubject OCTET STRING,
|
||
wtWebioAn8GraphAlarmMailText OCTET STRING,
|
||
wtWebioAn8GraphAlarmManagerIP OCTET STRING,
|
||
wtWebioAn8GraphAlarmTrapText OCTET STRING,
|
||
wtWebioAn8GraphAlarmMailOptions OCTET STRING,
|
||
wtWebioAn8GraphAlarmTcpIpAddr OCTET STRING,
|
||
wtWebioAn8GraphAlarmTcpPort INTEGER,
|
||
wtWebioAn8GraphAlarmTcpText OCTET STRING,
|
||
wtWebioAn8GraphAlarmClearMailSubject OCTET STRING,
|
||
wtWebioAn8GraphAlarmClearMailText OCTET STRING,
|
||
wtWebioAn8GraphAlarmClearTrapText OCTET STRING,
|
||
wtWebioAn8GraphAlarmClearTcpText OCTET STRING,
|
||
wtWebioAn8GraphAlarmSyslogIpAddr OCTET STRING,
|
||
wtWebioAn8GraphAlarmSyslogPort INTEGER,
|
||
wtWebioAn8GraphAlarmSyslogText OCTET STRING,
|
||
wtWebioAn8GraphAlarmFtpDataPort OCTET STRING,
|
||
wtWebioAn8GraphAlarmFtpFileName OCTET STRING,
|
||
wtWebioAn8GraphAlarmFtpText OCTET STRING,
|
||
wtWebioAn8GraphAlarmFtpClearText OCTET STRING,
|
||
wtWebioAn8GraphAlarmFtpOption OCTET STRING,
|
||
wtWebioAn8GraphAlarmTimerCron OCTET STRING
|
||
|
||
}
|
||
|
||
wtWebioAn8GraphAlarmTrigger OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded trigger conditions:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3:
|
||
Bit 0: Timer
|
||
Bit 1: ColdStart
|
||
Bit 2: WarmStart
|
||
|
||
Octet 4:
|
||
Bit 0: Sensor 1
|
||
Bit 1: Sensor 2
|
||
Bit 2: Sensor 3
|
||
Bit 3: Sensor 4
|
||
Bit 4: Sensor 5
|
||
Bit 5: Sensor 6
|
||
Bit 6: Sensor 7
|
||
Bit 7: Sensor 8"
|
||
::= { wtWebioAn8GraphAlarmEntry 1 }
|
||
|
||
wtWebioAn8GraphAlarmMin OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Minimum temperature in degrees with maximum 2 decimal places."
|
||
::= { wtWebioAn8GraphAlarmEntry 2 }
|
||
|
||
wtWebioAn8GraphAlarmMax OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximum temperature in degrees with maximum 2 decimal places."
|
||
::= { wtWebioAn8GraphAlarmEntry 3 }
|
||
|
||
wtWebioAn8GraphAlarmHysteresis OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
|
||
, in degrees with maximum 2 decimal places."
|
||
::= { wtWebioAn8GraphAlarmEntry 4 }
|
||
|
||
wtWebioAn8GraphAlarmDelay OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm will be delayed by setting this time while stable alarm
|
||
condition occur (time in minutes)."
|
||
::= { wtWebioAn8GraphAlarmEntry 5 }
|
||
|
||
|
||
wtWebioAn8GraphAlarmInterval OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Send interval for alarm messages."
|
||
::= { wtWebioAn8GraphAlarmEntry 6 }
|
||
|
||
wtWebioAn8GraphAlarmEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded alarm enable:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0: Mail Enable
|
||
Bit 1: SNMP Trap enable
|
||
Bit 2: TCP Client enable"
|
||
::= { wtWebioAn8GraphAlarmEntry 7 }
|
||
|
||
wtWebioAn8GraphAlarmEMailAddr OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"E-Mail address for sending the alarm mail to."
|
||
::= { wtWebioAn8GraphAlarmEntry 8 }
|
||
|
||
wtWebioAn8GraphAlarmMailSubject OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Subject line for alarm mail."
|
||
::= { wtWebioAn8GraphAlarmEntry 9 }
|
||
|
||
wtWebioAn8GraphAlarmMailText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm mail text: <Tn> provides the current temperature; n = 1..8.
|
||
<Z> provides the current time."
|
||
::= { wtWebioAn8GraphAlarmEntry 10 }
|
||
|
||
wtWebioAn8GraphAlarmManagerIP OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name or IP address of the SNMP Manager which accepts the trap."
|
||
::= { wtWebioAn8GraphAlarmEntry 11 }
|
||
|
||
wtWebioAn8GraphAlarmTrapText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This text is sent in the trap body."
|
||
::= { wtWebioAn8GraphAlarmEntry 12 }
|
||
|
||
wtWebioAn8GraphAlarmMailOptions OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded options:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0 : Attach Thermo.csv Enable
|
||
Bit 1 : CSV-Data_since_last_report
|
||
Bit 2-7: unused"
|
||
::= { wtWebioAn8GraphAlarmEntry 13 }
|
||
|
||
wtWebioAn8GraphAlarmTcpIpAddr OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name or IP address of the TCP server which accepts the trap."
|
||
::= { wtWebioAn8GraphAlarmEntry 14 }
|
||
|
||
wtWebioAn8GraphAlarmTcpPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Port number of the TCP server which accepts the trap."
|
||
::= { wtWebioAn8GraphAlarmEntry 15 }
|
||
|
||
wtWebioAn8GraphAlarmTcpText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This text is sent in the TCP trap body."
|
||
::= { wtWebioAn8GraphAlarmEntry 16 }
|
||
|
||
wtWebioAn8GraphAlarmClearMailSubject OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Subject line for alarm clear mail."
|
||
::= { wtWebioAn8GraphAlarmEntry 17 }
|
||
|
||
wtWebioAn8GraphAlarmClearMailText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
|
||
<Z> provides the current time."
|
||
::= { wtWebioAn8GraphAlarmEntry 18 }
|
||
|
||
wtWebioAn8GraphAlarmClearTrapText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This text is sent in the trap body."
|
||
::= { wtWebioAn8GraphAlarmEntry 19 }
|
||
|
||
wtWebioAn8GraphAlarmClearTcpText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This text is sent in the TCP trap body."
|
||
::= { wtWebioAn8GraphAlarmEntry 20 }
|
||
|
||
wtWebioAn8GraphAlarmSyslogIpAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP address of the syslog server to which the Webio device should send syslog messages."
|
||
::= { wtWebioAn8GraphAlarmEntry 21 }
|
||
|
||
wtWebioAn8GraphAlarmSyslogPort OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Port number of the syslog server to which the Webio device should send syslog messages."
|
||
::= { wtWebioAn8GraphAlarmEntry 22 }
|
||
|
||
wtWebioAn8GraphAlarmSyslogText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
||
This text appears in the following syslog message body."
|
||
::= { wtWebioAn8GraphAlarmEntry 23 }
|
||
|
||
wtWebioAn8GraphAlarmSyslogClearText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
||
This text appears in the following syslog message body."
|
||
::= { wtWebioAn8GraphAlarmEntry 24 }
|
||
|
||
wtWebioAn8GraphAlarmFtpDataPort OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
||
::= { wtWebioAn8GraphAlarmEntry 25 }
|
||
|
||
wtWebioAn8GraphAlarmFtpFileName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name of the file including path informations."
|
||
::= { wtWebioAn8GraphAlarmEntry 26 }
|
||
|
||
wtWebioAn8GraphAlarmFtpText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Message text to store on the FTP server."
|
||
::= { wtWebioAn8GraphAlarmEntry 27 }
|
||
|
||
wtWebioAn8GraphAlarmFtpClearText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm clear message to store on the FTP server."
|
||
::= { wtWebioAn8GraphAlarmEntry 28 }
|
||
|
||
wtWebioAn8GraphAlarmFtpOptions OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded options, select only one option at the same time:
|
||
STORE = replace file
|
||
APPEND = append message at the end of the file
|
||
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0 : STORE
|
||
Bit 1 : APPEND
|
||
Bit 2-7: unused"
|
||
::= { wtWebioAn8GraphAlarmEntry 29 }
|
||
|
||
wtWebioAn8GraphAlarmTimerCron OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This entry contains 5 text fields space or tab seperated for time trigger definition.
|
||
Each field must match with the actual time to trigger a message, weekday and day of month
|
||
are interpreted separatley.
|
||
1: Minutes Range 0-59
|
||
2. Hours Range 0-23, 0 is midnight
|
||
3: Day of month Range 1-31
|
||
4: Month Range 1-12
|
||
5: Weekday Range 0-6, 0 is sunday
|
||
|
||
Syntax for every field:
|
||
- an asterix (*) enables every possible setting of a field
|
||
- single numbers seperated by commas
|
||
- a partition within the allowed range (1-5)
|
||
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
||
::= { wtWebioAn8GraphAlarmEntry 30 }
|
||
|
||
-- wtWebioAn8GraphGraphicsBase Group
|
||
----------------------------
|
||
|
||
wtWebioAn8GraphGraphicsBaseEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Defines the viewing options of the graphic:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0 : Auto scroll enable
|
||
Bit 1 : Show table
|
||
Bit 2 : Show graph
|
||
Bit 3 : Show control buttons
|
||
Bit 4 : Show config menu
|
||
Bit 5-7: unused"
|
||
::= { wtWebioAn8GraphGraphicsBase 1 }
|
||
|
||
wtWebioAn8GraphGraphicsBaseWidth OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Defines the width of the graphic in pixels."
|
||
::= { wtWebioAn8GraphGraphicsBase 2 }
|
||
|
||
wtWebioAn8GraphGraphicsBaseHeight OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Defines the height of the graphic in pixels."
|
||
::= { wtWebioAn8GraphGraphicsBase 3 }
|
||
|
||
wtWebioAn8GraphGraphicsBaseFrameColor OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(3))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Frame color definition in RGB."
|
||
::= { wtWebioAn8GraphGraphicsBase 4 }
|
||
|
||
wtWebioAn8GraphGraphicsBaseBackgroundColor OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(3))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Background color definition in RGB."
|
||
::= { wtWebioAn8GraphGraphicsBase 5 }
|
||
|
||
wtWebioAn8GraphGraphicsBasePollingrate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Defines the pollingrate in seconds,
|
||
which defines the refreshing intervall of the graphic."
|
||
::= { wtWebioAn8GraphGraphicsBase 6 }
|
||
|
||
-- wtWebioAn8GraphGraphicsSelect Group
|
||
----------------------------
|
||
|
||
wtWebioAn8GraphGraphicsSelectDisplaySensorSel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded sensor selection:
|
||
only selected sensors will be shown in the graphical presentation:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0: Sensor 1
|
||
Bit 1: Sensor 2
|
||
Bit 2: Sensor 3
|
||
Bit 3: Sensor 4
|
||
Bit 4: Sensor 5
|
||
Bit 5: Sensor 6
|
||
Bit 6: Sensor 7
|
||
Bit 7: Sensor 8"
|
||
::= { wtWebioAn8GraphGraphicsSelect 1 }
|
||
|
||
wtWebioAn8GraphGraphicsSelectDisplayShowExtrem OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Binary coded sensor selection:
|
||
only selected sensors will be shown with minima and maxima:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0: Sensor 1
|
||
Bit 1: Sensor 2
|
||
Bit 2: Sensor 3
|
||
Bit 3: Sensor 4
|
||
Bit 4: Sensor 5
|
||
Bit 5: Sensor 6
|
||
Bit 6: Sensor 7
|
||
Bit 7: Sensor 8"
|
||
::= { wtWebioAn8GraphGraphicsSelect 2 }
|
||
|
||
-- Graph Sensor Color Table
|
||
|
||
wtWebioAn8GraphSensorColorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebioAn8GraphSensorColorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"List of sensor colors for the praphical presentation."
|
||
::= { wtWebioAn8GraphGraphicsSelect 3 }
|
||
|
||
wtWebioAn8GraphSensorColorEntry OBJECT-TYPE
|
||
SYNTAX WtWebioAn8GraphSensorColorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Numbers of the sensors."
|
||
INDEX { wtWebioAn8GraphSensorNo }
|
||
::= { wtWebioAn8GraphSensorColorTable 1 }
|
||
|
||
WtWebioAn8GraphSensorColorEntry ::= SEQUENCE {
|
||
wtWebioAn8GraphGraphicsSensorColor OCTET STRING,
|
||
wtWebioAn8GraphGraphicsSelectScale OCTET STRING
|
||
}
|
||
|
||
wtWebioAn8GraphGraphicsSensorColor OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(3))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Color of the sensors at the praphical presention."
|
||
::= { wtWebioAn8GraphSensorColorEntry 1 }
|
||
|
||
wtWebioAn8GraphGraphicsSelectScale OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Assignes one of 4 scales to a sensor:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0 : Use Scale 1
|
||
Bit 1 : Use Scale 2
|
||
Bit 2 : Use Scale 3
|
||
Bit 3 : Use Scale 4
|
||
Bit 4-7: unused"
|
||
::= { wtWebioAn8GraphSensorColorEntry 2 }
|
||
|
||
-- wtWebioAn8GraphGraphicsScale Group
|
||
----------------------------
|
||
|
||
wtWebioAn8GraphGraphicsScaleAutoScaleEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Select the Auto Scale Mode:
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0 : Scale 1 Auto scale enable
|
||
Bit 1 : Scale 2 Auto scale enable
|
||
Bit 2 : Scale 3 Auto scale enable
|
||
Bit 3 : Scale 4 Auto scale enable
|
||
Bit 4-7: unused"
|
||
::= { wtWebioAn8GraphGraphicsScale 1 }
|
||
|
||
|
||
wtWebioAn8GraphGraphicsScaleAutoFitEnable OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Select the Auto Fit Mode::
|
||
Octet 1: unused
|
||
Octet 2: unused
|
||
Octet 3: unused
|
||
Octet 4:
|
||
Bit 0 : Scale 1 Auto fit enable
|
||
Bit 1 : Scale 2 Auto fit enable
|
||
Bit 2 : Scale 3 Auto fit enable
|
||
Bit 3 : Scale 4 Auto fit enable
|
||
Bit 4-7: unused"
|
||
::= { wtWebioAn8GraphGraphicsScale 2 }
|
||
|
||
wtWebioAn8GraphGraphicsScale1Min OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 1: Minimum."
|
||
::= { wtWebioAn8GraphGraphicsScale 3 }
|
||
|
||
wtWebioAn8GraphGraphicsScale2Min OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 2: Minimum."
|
||
::= { wtWebioAn8GraphGraphicsScale 4 }
|
||
|
||
wtWebioAn8GraphGraphicsScale3Min OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 3: Minimum."
|
||
::= { wtWebioAn8GraphGraphicsScale 5 }
|
||
|
||
wtWebioAn8GraphGraphicsScale4Min OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 4: Minimum."
|
||
::= { wtWebioAn8GraphGraphicsScale 6 }
|
||
|
||
wtWebioAn8GraphGraphicsScale1Max OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 1: Maximum."
|
||
::= { wtWebioAn8GraphGraphicsScale 7 }
|
||
|
||
wtWebioAn8GraphGraphicsScale2Max OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 2: Maximum."
|
||
::= { wtWebioAn8GraphGraphicsScale 8 }
|
||
|
||
wtWebioAn8GraphGraphicsScale3Max OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 3: Maximum."
|
||
::= { wtWebioAn8GraphGraphicsScale 9 }
|
||
|
||
wtWebioAn8GraphGraphicsScale4Max OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 4: Maximum."
|
||
::= { wtWebioAn8GraphGraphicsScale 10 }
|
||
|
||
wtWebioAn8GraphGraphicsScale1Unit OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 1: Unit."
|
||
::= { wtWebioAn8GraphGraphicsScale 11 }
|
||
|
||
wtWebioAn8GraphGraphicsScale2Unit OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 2: Unit."
|
||
::= { wtWebioAn8GraphGraphicsScale 12 }
|
||
|
||
wtWebioAn8GraphGraphicsScale3Unit OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 3: Unit."
|
||
::= { wtWebioAn8GraphGraphicsScale 13 }
|
||
|
||
wtWebioAn8GraphGraphicsScale4Unit OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Scale 4: Unit."
|
||
::= { wtWebioAn8GraphGraphicsScale 14 }
|
||
|
||
-- wtWebioAn8GraphPorts Group
|
||
----------------------------
|
||
|
||
-- Table
|
||
|
||
wtWebioAn8GraphPortTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF WtWebioAn8GraphPortEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"List of settings depending on the sensor number."
|
||
::= { wtWebioAn8GraphPorts 1 }
|
||
|
||
wtWebioAn8GraphPortEntry OBJECT-TYPE
|
||
SYNTAX WtWebioAn8GraphPortEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Sensor parameters for the individual sensors."
|
||
INDEX { wtWebioAn8GraphSensorNo }
|
||
::= { wtWebioAn8GraphPortTable 1 }
|
||
|
||
WtWebioAn8GraphPortEntry ::= SEQUENCE {
|
||
wtWebioAn8GraphPortName OCTET STRING,
|
||
wtWebioAn8GraphPortText OCTET STRING,
|
||
wtWebioAn8GraphPortOffset1 OCTET STRING,
|
||
wtWebioAn8GraphPortTemperature1 OCTET STRING,
|
||
wtWebioAn8GraphPortOffset2 OCTET STRING,
|
||
wtWebioAn8GraphPortTemperature2 OCTET STRING,
|
||
wtWebioAn8GraphPortComment OCTET STRING,
|
||
wtWebioAn8GraphPortSensorSelect OCTET STRING
|
||
|
||
|
||
}
|
||
|
||
wtWebioAn8GraphPortName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name of the sensor."
|
||
::= { wtWebioAn8GraphPortEntry 1 }
|
||
|
||
wtWebioAn8GraphPortText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Description of the sensor."
|
||
::= { wtWebioAn8GraphPortEntry 2 }
|
||
|
||
wtWebioAn8GraphPortOffset1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1."
|
||
::= { wtWebioAn8GraphPortEntry 3 }
|
||
|
||
wtWebioAn8GraphPortTemperature1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
|
||
::= { wtWebioAn8GraphPortEntry 4 }
|
||
|
||
wtWebioAn8GraphPortOffset2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2."
|
||
::= { wtWebioAn8GraphPortEntry 5 }
|
||
|
||
wtWebioAn8GraphPortTemperature2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
|
||
::= { wtWebioAn8GraphPortEntry 6 }
|
||
|
||
wtWebioAn8GraphPortComment OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Offset calibration: informations of date, name of operator, reference devices."
|
||
::= { wtWebioAn8GraphPortEntry 7 }
|
||
|
||
wtWebioAn8GraphPortSensorSelect OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(4))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Bin<69>r kodierte Optionen f<>r Sensor:
|
||
Octet 1: ungenutzt
|
||
Octet 2: ungenutzt
|
||
Octet 3: ungenutzt
|
||
Octet 4:
|
||
Bit 0 : PT100
|
||
Bit 1 : PT1000 (default)
|
||
Bit 2-7: ungenutzt"
|
||
::= { wtWebioAn8GraphPortEntry 8 }
|
||
|
||
-- wtWebioAn8GraphManufact Group
|
||
----------------------------
|
||
|
||
wtWebioAn8GraphMfName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Manufacturer company name"
|
||
::= { wtWebioAn8GraphManufact 1 }
|
||
|
||
wtWebioAn8GraphMfAddr OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Manufacturer address."
|
||
::= { wtWebioAn8GraphManufact 2 }
|
||
|
||
wtWebioAn8GraphMfHotline OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Manufacturer hotline."
|
||
::= { wtWebioAn8GraphManufact 3 }
|
||
|
||
wtWebioAn8GraphMfInternet OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Manufacturer Internet address."
|
||
::= { wtWebioAn8GraphManufact 4 }
|
||
|
||
wtWebioAn8GraphMfDeviceTyp OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Manufacturer device name (model number)."
|
||
::= { wtWebioAn8GraphManufact 5 }
|
||
|
||
wtWebioAn8GraphMfOrderNo OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Manufacturer part number."
|
||
::= { wtWebioAn8GraphManufact 6 }
|
||
|
||
-- wtWebioAn8GraphDiag Group
|
||
----------------------------
|
||
|
||
wtWebioAn8GraphDiagErrorCount OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Number of entries in the error memory."
|
||
::= { wtWebioAn8GraphDiag 1 }
|
||
|
||
wtWebioAn8GraphDiagBinaryError OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Error causes coded bit-by-bit."
|
||
::= { wtWebioAn8GraphDiag 2 }
|
||
|
||
wtWebioAn8GraphDiagErrorIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The value of this variable is used as an index to read
|
||
an error massege from wtWebioAn8GraphDiagErrorMessage.
|
||
Errors are numbered from 1 to wtWebioAn8GraphDiagErrorCount.
|
||
Writing a valid value into this variable, making the appropriate
|
||
message readable from wtWebioAn8GraphDiagErrorMessage."
|
||
::= { wtWebioAn8GraphDiag 3 }
|
||
|
||
wtWebioAn8GraphDiagErrorMessage OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Using wtWebioAn8GraphDiagErrorIndex as an index, the appropriate message is available."
|
||
::= { wtWebioAn8GraphDiag 4 }
|
||
|
||
wtWebioAn8GraphDiagErrorClear OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Writing 1 into this variable clears all diagnosis messages."
|
||
::= { wtWebioAn8GraphDiag 5 }
|
||
|
||
-- TRAP DEFINITIONS
|
||
|
||
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
||
|
||
wtWebioAn8GraphAlert1 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 1 was triggered,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Alarm 1"
|
||
--#SUMMARY "Alarm 1: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 11
|
||
|
||
wtWebioAn8GraphAlert2 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 2 was triggered,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Alarm 2"
|
||
--#SUMMARY "Alarm 2: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 12
|
||
|
||
wtWebioAn8GraphAlert3 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 3 was triggered,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Alarm 3"
|
||
--#SUMMARY "Alarm 3: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 13
|
||
|
||
wtWebioAn8GraphAlert4 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 4 was triggered,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Alarm 4"
|
||
--#SUMMARY "Alarm 4: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 14
|
||
|
||
wtWebioAn8GraphAlert5 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 5 was triggered,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Alarm 5"
|
||
--#SUMMARY "Alarm 5: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 15
|
||
|
||
wtWebioAn8GraphAlert6 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 6 was triggered,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Alarm 6"
|
||
--#SUMMARY "Alarm 6: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 16
|
||
|
||
wtWebioAn8GraphAlert7 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 7 was triggered,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Alarm 7"
|
||
--#SUMMARY "Alarm 7: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 17
|
||
|
||
wtWebioAn8GraphAlert8 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 8 was triggered,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Alarm 8"
|
||
--#SUMMARY "Alarm 8: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 18
|
||
|
||
|
||
wtWebioAn8GraphAlert9 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 1 was cleared,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Release Alarm 1"
|
||
--#SUMMARY "Release Alarm 1: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 71
|
||
|
||
wtWebioAn8GraphAlert10 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 2 was cleared,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Release Alarm 2"
|
||
--#SUMMARY "Release Alarm 2: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 72
|
||
|
||
wtWebioAn8GraphAlert11 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 3 was cleared,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Release Alarm 3"
|
||
--#SUMMARY "Release Alarm 3: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 73
|
||
|
||
wtWebioAn8GraphAlert12 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 4 was cleared,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Release Alarm 4"
|
||
--#SUMMARY "Release Alarm 4: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 74
|
||
|
||
wtWebioAn8GraphAlert13 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 5 was cleared,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Release Alarm 5"
|
||
--#SUMMARY "Release Alarm 5: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 75
|
||
|
||
wtWebioAn8GraphAlert14 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 6 was cleared,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Release Alarm 6"
|
||
--#SUMMARY "Release Alarm 6: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 76
|
||
|
||
wtWebioAn8GraphAlert15 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 7 was cleared,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Release Alarm 7"
|
||
--#SUMMARY "Release Alarm 7: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 77
|
||
|
||
wtWebioAn8GraphAlert16 TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES { wtWebioAn8GraphAlarmClearTrapText }
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when Alarm 8 was cleared,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Release Alarm 8"
|
||
--#SUMMARY "Release Alarm 8: %s"
|
||
--#ARGUMENTS {0}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
::= 78
|
||
|
||
wtWebioAn8GraphAlertDiag TRAP-TYPE
|
||
ENTERPRISE wtWebioAn8Graph
|
||
VARIABLES {
|
||
wtWebioAn8GraphDiagErrorIndex,
|
||
wtWebioAn8GraphDiagErrorMessage
|
||
}
|
||
DESCRIPTION
|
||
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
||
SNMP trap enable is set and
|
||
SNMP is enabled."
|
||
-- NMS trap annotation
|
||
--#TYPE "Web-Thermograph Diagnose Error"
|
||
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
||
--#ARGUMENTS {0,1}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
::= 110
|
||
|
||
END
|