- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
439 lines
14 KiB
Text
439 lines
14 KiB
Text
--*******************************************************************
|
|
--* SAGEM SA *
|
|
--*******************************************************************
|
|
--*******************************************************************
|
|
|
|
-- Filename: connection
|
|
-- File type: .mib
|
|
--
|
|
-- Description: SNMPc source Mib file.
|
|
--
|
|
-- Version: 19 11 2002
|
|
--
|
|
-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
|
|
--
|
|
-- Contact: D. Mobuchon, F. Bonnevialle
|
|
--
|
|
-- History:
|
|
-- Name: F.Bonnevialle
|
|
-- Date: 12 12 2000
|
|
-- Desc: original
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 22 02 2001
|
|
-- Desc: * Access right Modifications (from "Read-write" to "Read-Only") of some
|
|
-- LinkTable variables .
|
|
-- Use the Xcon vector to add or delete TableLink elements.
|
|
-- * Modification of the LinkDirection enum in order to
|
|
-- match up its values with those of the ADR equipment.
|
|
-- * Modification of Xcon vector in order to add the new variable xconAction,
|
|
-- which indicates the kind of the action (Creation(1) or Deletion(2))
|
|
-- * The linkImplementation variable, which should allow to reserve a
|
|
-- connection without physical implementation, is maintained (for a next use)
|
|
-- but is not implemented in the SNMP Agent (its value is always set to TRUE)
|
|
-- * The 6 subelements of the name of the connexion have been replaced by
|
|
-- a unique variable: xconName (which matches to M1400 format)
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 19 04 2001
|
|
-- Desc: * Modification of the CTPType values
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 25 04 2001
|
|
-- Desc: * Change the MIB number: {Sagem 120} -> {Sagem 108}
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 10 08 2001
|
|
-- Desc: * LinkImplementation Access right Modification
|
|
-- (from "Read-Only" to "Read-Write")
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 22 05 2002
|
|
-- Desc: * Add a new CTPType Value: nspi(100)
|
|
--
|
|
-- Name: F.Bonnevialle
|
|
-- Date: 15 11 2002
|
|
-- Desc: Modification for SilverCreek Compiler
|
|
--
|
|
--*******************************************************************
|
|
--*******************************************************************
|
|
--* Copyright (c) 2002, SAGEM , All rights reserved. *
|
|
--*******************************************************************
|
|
|
|
|
|
--*******************************************************************
|
|
-- MIB: XCONNECTION-MIB
|
|
--*******************************************************************
|
|
XCONNECTION-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--*******************************************************************
|
|
-- IMPORTS
|
|
--*******************************************************************
|
|
|
|
IMPORTS
|
|
sagemDr FROM SAGEM-DR-MIB
|
|
SagemBoolean FROM EQUIPMENT-MIB
|
|
MODULE-IDENTITY,OBJECT-TYPE FROM SNMPv2-SMI
|
|
DisplayString FROM SNMPv2-TC; --RFC1213-MIB;
|
|
|
|
|
|
|
|
xconnection MODULE-IDENTITY
|
|
LAST-UPDATED "0205220000Z"
|
|
ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
|
|
CONTACT-INFO
|
|
" "
|
|
DESCRIPTION
|
|
"The MIB module describes connection in physical layer
|
|
of transmission equipements such as pdh/sdh mux and cross connect.
|
|
This mib assumes that terminaison point are provided by other mibs,
|
|
such as sdh.mib.
|
|
xconnection is a particular case of SubNetworkConnection defined
|
|
in ETS 300 653"
|
|
::= { sagemDr 108}
|
|
|
|
-- linkTable
|
|
link OBJECT IDENTIFIER ::= { xconnection 10 }
|
|
|
|
-- create/delete connection
|
|
xcon OBJECT IDENTIFIER ::= { xconnection 30 }
|
|
|
|
--*******************************************************************
|
|
-- Link
|
|
--*******************************************************************
|
|
TrafficStatus ::= INTEGER
|
|
{
|
|
none(0), -- Future case of a non-implemented link
|
|
working(1),
|
|
protection(2)
|
|
}
|
|
|
|
ProtectionType ::= INTEGER
|
|
{
|
|
none(0),
|
|
snc(1)
|
|
}
|
|
|
|
ProtectionStatus ::= INTEGER
|
|
{
|
|
none(0),
|
|
used(1)
|
|
}
|
|
|
|
LinkDirection ::= INTEGER
|
|
{
|
|
unidirectional(1),
|
|
bidirectional(2)
|
|
}
|
|
|
|
CTPType ::= INTEGER
|
|
{
|
|
unknown(0),
|
|
au(1),
|
|
au4c(2),
|
|
au16c(3),
|
|
tu3(10),
|
|
tu12(20),
|
|
pdh2M (50),
|
|
pdh34M (51),
|
|
pdh45M (52),
|
|
pdh140M (53),
|
|
eth10M(60),
|
|
eth100M(61),
|
|
eth1G(62),
|
|
nspi(100)
|
|
}
|
|
|
|
linkNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of cross connections in equipment."
|
|
::= { link 1 }
|
|
|
|
linkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of link in equipment. For example, a bidirectionnal
|
|
connection is composed of 2 links. A SNC protected bidirectionnal
|
|
connection is composed of 3 permanent links ."
|
|
::= { link 2 }
|
|
|
|
linkEntry OBJECT-TYPE
|
|
SYNTAX LinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular synchronous physical interface of the equipment."
|
|
INDEX { linkIndex }
|
|
::= { linkTable 1 }
|
|
|
|
LinkEntry ::= SEQUENCE
|
|
{
|
|
linkIndex INTEGER,
|
|
linkSinkType CTPType,
|
|
linkSrcType CTPType,
|
|
linkCTPSink INTEGER,
|
|
linkCTPSource INTEGER,
|
|
linkName DisplayString,
|
|
linkGroupId INTEGER,
|
|
linkDirection LinkDirection,
|
|
linkProtectionType ProtectionType,
|
|
linkProtectionStatus ProtectionStatus,
|
|
linkTrafficStatus TrafficStatus,
|
|
linkImplementation SagemBoolean
|
|
}
|
|
|
|
linkIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"linkIndex = number of the CTP Output
|
|
= sncIndex "
|
|
::= { linkEntry 1 }
|
|
|
|
linkSinkType OBJECT-TYPE
|
|
SYNTAX CTPType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Kind of CTP table from which the connection is issued"
|
|
::= { linkEntry 2 }
|
|
|
|
linkSrcType OBJECT-TYPE
|
|
SYNTAX CTPType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Kind of CTP table from which the connection is issued"
|
|
::= { linkEntry 3 }
|
|
|
|
linkCTPSink OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates the Ouput
|
|
Connection Point which composes the unidirectionnal
|
|
link.It's an index in considerated TTP table
|
|
linkCTPSink = linkIndex"
|
|
::= { linkEntry 4 }
|
|
|
|
linkCTPSource OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates the Input
|
|
Connection Point which composes the unidirectionnal
|
|
link. It's an index in considerated TTP table "
|
|
::= { linkEntry 5 }
|
|
|
|
linkName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the name of this link.
|
|
Links names of a bidirectionnal link must have different name.
|
|
Same direction SNC protected links have an identical name.
|
|
M1400 UIT-T specifies the field's format "
|
|
::= { linkEntry 6 }
|
|
|
|
linkGroupId OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A group identifier is used to group links by community."
|
|
::= { linkEntry 7 }
|
|
|
|
linkDirection OBJECT-TYPE
|
|
SYNTAX LinkDirection
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unidirectional or Bidirectionnal connections."
|
|
::= { linkEntry 8 }
|
|
|
|
linkProtectionType OBJECT-TYPE
|
|
SYNTAX ProtectionType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates the kind of wanted link protection.
|
|
The default value is NONE.
|
|
if value is changed in Snc(1)then an entry is created in Snc table with the same index. But this table
|
|
has to be completed (by setting the PIC,...) to obtain a configured protection.
|
|
if value is changed in None(0)then the associated entry in Snc table is deleted.
|
|
When the value is set to Snc for a particular entry of LinkTable, other links which are in relation (of
|
|
direction or protection) with this main link remain setting to None for this field. But all links are set to the USED(1) value
|
|
in the next field (linkProtectionStatus)"
|
|
::= { linkEntry 9 }
|
|
|
|
linkProtectionStatus OBJECT-TYPE
|
|
SYNTAX ProtectionStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates if the link is used directly or not in a Snc protection.
|
|
For a non-protected link, this field is mandatory set to None.
|
|
The field value particulary allow to know the hability of link deletion."
|
|
::= { linkEntry 10 }
|
|
|
|
linkTrafficStatus OBJECT-TYPE
|
|
SYNTAX TrafficStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates where is the traffic.
|
|
For a non-protected link, this field is mandatory set to working"
|
|
::= { linkEntry 11 }
|
|
|
|
linkImplementation OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actually, this variable is not implemented (always set to TRUE).
|
|
But it could be used to allow to reserve a connection without physical implementation"
|
|
::= { linkEntry 12 }
|
|
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
-- xcon : creation/deletion of Xconnection
|
|
-- This vector has been created to allow to:
|
|
-- * create or delete Xconnection in an atomic way (no need to use Set All command)
|
|
-- * keep critical variable of linkTable (such as linkIndex) in a Read-Only Access
|
|
-- * get back a special message in case of trouble.
|
|
--*******************************************************************
|
|
XconDir ::= INTEGER
|
|
{
|
|
unknown(0), -- Future case of a non-implemented link
|
|
unidirectional(1),
|
|
bidirectional(2)
|
|
}
|
|
|
|
ActionType ::= INTEGER
|
|
{
|
|
unknown(0),
|
|
creation(1),
|
|
deletion(2)
|
|
}
|
|
|
|
|
|
xconNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of connection to process."
|
|
::= { xcon 1 }
|
|
|
|
xconSinkType OBJECT-TYPE
|
|
SYNTAX CTPType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of CTP"
|
|
::= { xcon 2 }
|
|
|
|
xconSinkIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output CTP"
|
|
::= { xcon 3 }
|
|
|
|
xconSrcType OBJECT-TYPE
|
|
SYNTAX CTPType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of CTP"
|
|
::= { xcon 4 }
|
|
|
|
xconSrcIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input CTP"
|
|
::= { xcon 5 }
|
|
|
|
xconDirection OBJECT-TYPE
|
|
SYNTAX XconDir
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bidirectionnal connections are composed of two unidirectional xcon
|
|
and therefore 2 link entries."
|
|
::= { xcon 6 }
|
|
|
|
xconName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the name of this cross-connection.
|
|
M1400 UIT-T specifies the field's format like this:
|
|
NameTownA/NameSuffixA-NameTownB/NameSuffixB NameFunctionSNameSerial
|
|
* NameTownX field accepts alpha-numeric and space characters.
|
|
NameTownB is preceded by a '-' character.
|
|
Maximum length is 12 charracters.
|
|
Not mandatory fields.
|
|
* NameSuffixX field accepts alpha-numeric characters.
|
|
It's preceded by a '/' character.
|
|
Maximum length is 3 characters.
|
|
Not mandatory fields.
|
|
* NameFunction field accepts alpha-numeric characters.
|
|
It's followed by a 'S' character.
|
|
Maximum length is 3 characters.
|
|
Mandatory field.
|
|
It represents the function code.
|
|
* NameSerial field accepts 4-figure number.
|
|
Not mandatory field.
|
|
It represents the serial number and will be incremented
|
|
automatically from the base serial number provided.
|
|
For ADR2500 equipments:
|
|
Links names of a bidirectionnal link must have different name.
|
|
Same direction SNC protected links have an identical name."
|
|
::= { xcon 7 }
|
|
|
|
|
|
xconAction OBJECT-TYPE
|
|
SYNTAX ActionType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of action: Unknown(0) or Creation(1) or deletion(2)"
|
|
::= { xcon 8 }
|
|
|
|
xconProceed OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This entry is use to create (set to `true').
|
|
The value of the field remains to `true' until creation is
|
|
completed or has been aborted.
|
|
"
|
|
::= { xcon 20 }
|
|
|
|
xconDiagnostic OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string used to help in case of trouble."
|
|
::= { xcon 21 }
|
|
|
|
END
|