- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
861 lines
26 KiB
Text
861 lines
26 KiB
Text
--*******************************************************************
|
|
--* SAGEM SA *
|
|
--*******************************************************************
|
|
--*******************************************************************
|
|
|
|
-- Filename: shelf
|
|
-- File type: .mib
|
|
--
|
|
-- Description: SNMPc source Mib file.
|
|
-- The MIB module defines structure for ADR equipement family
|
|
--
|
|
-- Version: 19 11 2002
|
|
--
|
|
-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
|
|
--
|
|
-- Contact: D. Mobuchon, F. Bonnevialle
|
|
--
|
|
-- History:
|
|
-- Version: MIB-P0-301199 Date: 30 11 1999
|
|
--
|
|
-- Name: F.Bonnevialle
|
|
-- Date: 12 12 2000
|
|
-- Desc: original
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 08 02 2001
|
|
-- Desc: * Change the MIB number: {Sagem 25} -> {Sagem 150}
|
|
-- * Add 7 equipment modification counters
|
|
-- * Add a specific index to the table "laserTable"
|
|
-- * Remove the configAction Object
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 18 04 2001
|
|
-- Desc: * Move the 7 equipment modification counters in the Equip Mib
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 01 06 2001
|
|
-- Desc: * Replace the BoardIndex Type by INTEGER and BoardFamily Type by a DisplayString.
|
|
-- * Add slotName object in the BoardTable
|
|
-- These modifications allow the MIB to be more independent of the equipment.
|
|
--
|
|
-- Name: F.Bonnevialle
|
|
-- Date: 15 11 2002
|
|
-- Desc: Modification for SilverCreek Compiler
|
|
--
|
|
--*******************************************************************
|
|
--*******************************************************************
|
|
--* Copyright (c) 2002, SAGEM , All rights reserved. *
|
|
--*******************************************************************
|
|
|
|
|
|
SHELF-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
sagemDr FROM SAGEM-DR-MIB
|
|
SagemBoolean, Severity FROM EQUIPMENT-MIB
|
|
MODULE-IDENTITY,OBJECT-TYPE,
|
|
Counter32 FROM SNMPv2-SMI
|
|
DisplayString FROM SNMPv2-TC;
|
|
--spiIndex FROM SDH-ETS-MIB;
|
|
|
|
|
|
shelf MODULE-IDENTITY
|
|
LAST-UPDATED "0012060000Z"
|
|
ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
|
|
CONTACT-INFO
|
|
""
|
|
DESCRIPTION
|
|
"The MIB module specific for ADR equipment"
|
|
::= { sagemDr 150 }
|
|
|
|
-- led
|
|
led OBJECT IDENTIFIER ::= { shelf 2 }
|
|
|
|
-- hold Time
|
|
holdTime OBJECT IDENTIFIER ::= { shelf 3 }
|
|
|
|
-- slot and board
|
|
board OBJECT IDENTIFIER ::= { shelf 20 }
|
|
|
|
-- board table
|
|
boardList OBJECT IDENTIFIER ::= { shelf 30 }
|
|
|
|
-- Software inventory
|
|
softInv OBJECT IDENTIFIER ::= { shelf 40 }
|
|
|
|
-- Harware inventory
|
|
hardInv OBJECT IDENTIFIER ::= { shelf 50 }
|
|
|
|
-- laser data
|
|
laser OBJECT IDENTIFIER ::= { shelf 100 }
|
|
|
|
-- engineering order wire
|
|
eow OBJECT IDENTIFIER ::= { shelf 120 }
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
--* Slot and Board
|
|
--*******************************************************************
|
|
boardNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of board in equipment."
|
|
::= { board 1 }
|
|
|
|
boardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of board in equipment."
|
|
::= { board 2 }
|
|
|
|
boardEntry OBJECT-TYPE
|
|
SYNTAX BoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular board of the equipment."
|
|
INDEX { boardIndex }
|
|
::= { boardTable 1 }
|
|
|
|
|
|
ProtectionType ::= INTEGER
|
|
{
|
|
none(0),
|
|
cardp(1)
|
|
}
|
|
|
|
BoardFailure ::= INTEGER
|
|
{
|
|
none(0),
|
|
missing(1),
|
|
mismatch(2),
|
|
defective(3)
|
|
}
|
|
|
|
BoardEntry ::= SEQUENCE
|
|
{
|
|
boardIndex INTEGER,
|
|
boardSlotName DisplayString,
|
|
boardExpectType INTEGER, -- 0 or boardListIndex
|
|
boardInsertType INTEGER, -- 0 or boardListIndex
|
|
boardExpectFamily DisplayString,
|
|
boardInsertFamily DisplayString,
|
|
boardActive SagemBoolean,
|
|
boardFirstPortIndex INTEGER,
|
|
boardProtectionType ProtectionType,
|
|
boardMonitor SagemBoolean,
|
|
boardFailure BoardFailure,
|
|
boardSeverity Severity,
|
|
boardMissingSev Severity,
|
|
boardMismatchSev Severity,
|
|
boardDefectiveSev Severity
|
|
}
|
|
|
|
boardIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular slot.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to hardware.
|
|
Each equipment maintain its own pool of values:
|
|
ex ADR155c : A = 1, B = 2, ... M = 5, Fan = 6
|
|
ex ADR2500c: Fan = 1, PSU1 = 2, ...Trib1 = 8, Trib6= 13, Line1 = 14,...
|
|
Switch2 = 17, Shelf = 18"
|
|
::= { boardEntry 1 }
|
|
|
|
boardSlotName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A DisplayString which identify the name of a particular slot.
|
|
Its value is fixed at equipment design time.
|
|
It is usualy related to hardware
|
|
ex ADR155c : A, B, ... Fan
|
|
ex ADR2500c: Fan, CCU, CTRL, PSU1, ... TRIB5, .... SWITCH1, ..."
|
|
::= { boardEntry 2 }
|
|
|
|
boardExpectType OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value which configure the expected type. If used, this one must be
|
|
equal to one of existent boardListIndex for the considerated board. Otherwise,
|
|
the value is set to 0.
|
|
Known types are readable in boardListTable
|
|
"
|
|
::= { boardEntry 3 }
|
|
|
|
boardInsertType OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the inserted board doesn't match with the expexted board
|
|
the boardMismatch failure is generated.
|
|
The type of the card could be found in hardware inventory."
|
|
::= { boardEntry 4 }
|
|
|
|
boardExpectFamily OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Board Family corresponding to the specified expected kind. This value is send by the equipment.
|
|
ex ADR155c :
|
|
ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, STM1 ERE, STM4 OPT, STM16 OPT, GBETH, SWITCH
|
|
"
|
|
::= { boardEntry 5 }
|
|
|
|
boardInsertFamily OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Board Family corresponding to the type of inserted board.
|
|
ex ADR155c :
|
|
ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, STM1 ERE, STM4 OPT, STM16 OPT, GBETH, SWITCH
|
|
"
|
|
::= { boardEntry 6 }
|
|
|
|
boardActive OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the transmission of
|
|
this board stop and the board could properly be extracted"
|
|
::= { boardEntry 7 }
|
|
|
|
boardFirstPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the card is a card with physical ports, then the value is
|
|
the first index of a physical interface (SPI, PPI) in the mib
|
|
SDH-ETS. Else, the value is 0."
|
|
::= { boardEntry 8 }
|
|
|
|
boardProtectionType OBJECT-TYPE
|
|
SYNTAX ProtectionType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates the kind of wanted card protection.
|
|
The default value is NONE.
|
|
if value is changed in cardP(1)then an entry is created in cardpTable. But this table
|
|
has to be completed (by setting the cardpReliefIndex,...) to obtain a configured protection.
|
|
if value is changed in None(0)then the associated entry in cardpTable is deleted.
|
|
Some cards don't accept any protection. In that case, the value of this field will remain to NONE"
|
|
::= { boardEntry 9 }
|
|
|
|
boardMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this board."
|
|
::= { boardEntry 10 }
|
|
|
|
boardFailure OBJECT-TYPE
|
|
SYNTAX BoardFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on board"
|
|
::= { boardEntry 11 }
|
|
|
|
boardSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for boards."
|
|
::= { boardEntry 12 }
|
|
|
|
|
|
boardMissingSev OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for boards."
|
|
::= { boardEntry 13 }
|
|
|
|
boardMismatchSev OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for boards."
|
|
::= { boardEntry 14 }
|
|
|
|
boardDefectiveSev OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for boards."
|
|
::= { boardEntry 15 }
|
|
|
|
--*******************************************************************
|
|
--* board list
|
|
--*******************************************************************
|
|
boardListNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of entry of the boardList Table"
|
|
::= { boardList 1 }
|
|
|
|
boardListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoardlistEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of board type able to be managed by this equipment .
|
|
In order to manage a new type, just insert the board and if
|
|
the family match with a known family, this table will be
|
|
expand automaticaly with the new type inserted
|
|
|
|
The XX fist value defined ( with boardSlotName = Shelf = 18 for ADR2500c)
|
|
is a list all possible type of boardInsertedType.
|
|
"
|
|
::= { boardList 2 }
|
|
|
|
boardListEntry OBJECT-TYPE
|
|
SYNTAX BoardlistEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular boardList of the equipment."
|
|
INDEX { boardListIndex }
|
|
::= { boardListTable 1 }
|
|
|
|
BoardlistEntry ::= SEQUENCE
|
|
{
|
|
boardListIndex INTEGER,
|
|
boardListSlot INTEGER,
|
|
boardListType DisplayString
|
|
}
|
|
|
|
boardListIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value."
|
|
::= { boardListEntry 1 }
|
|
|
|
boardListSlot OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the corresponding Slot."
|
|
::= { boardListEntry 2 }
|
|
|
|
boardListType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In order to manage a new type, just insert the board and if
|
|
the family match with a known family, this table will be
|
|
expand automaticaly with the new type inserted.
|
|
ex ADR155c :
|
|
ex ADR2500c: 4S1.1, S4.1, L16.2, SWITCH, ..."
|
|
::= { boardListEntry 3 }
|
|
|
|
|
|
--*******************************************************************
|
|
--* Software inventory
|
|
--*******************************************************************
|
|
|
|
softInventoryNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of entry of the softInventory Table"
|
|
::= { softInv 1 }
|
|
|
|
softInventoryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SoftInventoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of software inventory used "
|
|
::= { softInv 2 }
|
|
|
|
softInventoryEntry OBJECT-TYPE
|
|
SYNTAX SoftInventoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular boardList of the equipment."
|
|
INDEX { softInventoryIndex }
|
|
::= { softInventoryTable 1 }
|
|
|
|
SoftInventoryEntry ::= SEQUENCE
|
|
{
|
|
softInventoryIndex INTEGER,
|
|
softInventoryBoard INTEGER, -- boardIndex
|
|
softInventoryType DisplayString,
|
|
softInventoryCode DisplayString,
|
|
softInventoryExt DisplayString
|
|
}
|
|
|
|
softInventoryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value."
|
|
::= { softInventoryEntry 1 }
|
|
|
|
softInventoryBoard OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the corresponding Slot. This variable is needed because some
|
|
boards have their owns Applicative and Boot codes. "
|
|
::= { softInventoryEntry 2 }
|
|
|
|
softInventoryType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indication of type software"
|
|
::= { softInventoryEntry 3 }
|
|
|
|
softInventoryCode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indication of version code"
|
|
::= { softInventoryEntry 4 }
|
|
|
|
softInventoryExt OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indication of extension code. This one is not mandatory."
|
|
::= { softInventoryEntry 5 }
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
--* Hardware inventory
|
|
--*******************************************************************
|
|
|
|
hardInventoryNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of different hardware inventory in equipment."
|
|
::= { hardInv 1 }
|
|
|
|
hardInventoryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HardInventoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of hardware inventory in equipment.
|
|
A hardware inventory is a description associed to a
|
|
particular card"
|
|
::= { hardInv 2 }
|
|
|
|
hardInventoryEntry OBJECT-TYPE
|
|
SYNTAX HardInventoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular tInv of the equipment."
|
|
INDEX { hardInventoryIndex }
|
|
::= { hardInventoryTable 1 }
|
|
|
|
HardInventoryEntry ::= SEQUENCE {
|
|
hardInventoryIndex INTEGER, -- boardIndex
|
|
hardInventoryBoard DisplayString,
|
|
hardInventoryDescr DisplayString
|
|
}
|
|
|
|
hardInventoryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the inventory entry that corresponds to a particular slot"
|
|
::= { hardInventoryEntry 1 }
|
|
|
|
hardInventoryBoard OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Family of card inserted in the slot"
|
|
::= { hardInventoryEntry 2 }
|
|
|
|
hardInventoryDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The content of the inventory: a textual description"
|
|
::= { hardInventoryEntry 3 }
|
|
|
|
--*******************************************************************
|
|
--* laser
|
|
--*******************************************************************
|
|
laserNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of optical interface in equipment."
|
|
::= { laser 1 }
|
|
|
|
laserTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LaserEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of synchronous physical interface in equipment."
|
|
::= { laser 2 }
|
|
|
|
laserEntry OBJECT-TYPE
|
|
SYNTAX LaserEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular synchronous physical interface of the equipment."
|
|
-- INDEX { spiIndex }
|
|
INDEX { laserIndex }
|
|
|
|
::= { laserTable 1 }
|
|
|
|
LaserEntry ::= SEQUENCE
|
|
{
|
|
-- spiIndex INTEGER,
|
|
laserIndex INTEGER, -- =spiIndex
|
|
laserTxEnable SagemBoolean,
|
|
laserALSEnable SagemBoolean,
|
|
laserALSRestart2s SagemBoolean,
|
|
laserALSRestart90s SagemBoolean
|
|
}
|
|
|
|
laserIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" "
|
|
::= { laserEntry 1 }
|
|
|
|
laserTxEnable OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable(true) or disable(false) the laser output of the interface."
|
|
::= { laserEntry 2 }
|
|
|
|
laserALSEnable OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic Laser Shutdown enable(true) or disable(false).
|
|
When enabled, this function cuts the laser output when a los is
|
|
detected on input signal."
|
|
::= { laserEntry 3 }
|
|
|
|
laserALSRestart2s OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operator command to start a one shot emission during 2s."
|
|
::= { laserEntry 4 }
|
|
|
|
laserALSRestart90s OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operator command to start a one shot emission during 90s."
|
|
::= { laserEntry 5 }
|
|
-- end laser data
|
|
|
|
|
|
--*******************************************************************
|
|
--* Shelf
|
|
--*******************************************************************
|
|
adrHotReset OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software hot reset when this variable is set to TRUE"
|
|
::= { shelf 1 }
|
|
|
|
--*******************************************************************
|
|
--* led
|
|
--*******************************************************************
|
|
LedStatus ::= INTEGER
|
|
{
|
|
unknown (1),
|
|
green (2),
|
|
yellow (3),
|
|
orange (4),
|
|
red (5)
|
|
}
|
|
|
|
LedType ::= INTEGER
|
|
{
|
|
status1(1),
|
|
status2(2),
|
|
online (3),
|
|
traffic(4),
|
|
major (5),
|
|
minor (6),
|
|
ether (7),
|
|
halfFull (8)
|
|
}
|
|
|
|
ledNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of led in equipment."
|
|
::= { led 1 }
|
|
|
|
ledTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of led in equipment."
|
|
::= { led 2 }
|
|
|
|
ledEntry OBJECT-TYPE
|
|
SYNTAX LedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular led of the equipment."
|
|
INDEX { ledIndex }
|
|
::= { ledTable 1 }
|
|
|
|
LedEntry ::= SEQUENCE
|
|
{
|
|
ledIndex INTEGER,
|
|
ledPosition INTEGER, -- boardIndex
|
|
ledType LedType,
|
|
ledStatus LedStatus
|
|
}
|
|
|
|
ledIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular led."
|
|
::= { ledEntry 1 }
|
|
|
|
ledPosition OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the associated Board on the equipment."
|
|
::= { ledEntry 2 }
|
|
|
|
ledType OBJECT-TYPE
|
|
SYNTAX LedType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of the Led."
|
|
::= { ledEntry 3 }
|
|
|
|
ledStatus OBJECT-TYPE
|
|
SYNTAX LedStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of this Led."
|
|
::= { ledEntry 4 }
|
|
|
|
--*******************************************************************
|
|
--* hold time
|
|
--*******************************************************************
|
|
HoldTime ::= INTEGER
|
|
{
|
|
hold01sec(1),
|
|
hold03sec(3),
|
|
hold10sec(10),
|
|
hold30sec(30)
|
|
}
|
|
|
|
adrFailHoldOffTime OBJECT-TYPE
|
|
SYNTAX HoldTime
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Failure hold off time : the time interval during which the
|
|
defect is present and the failure is not raised"
|
|
::= { holdTime 1 }
|
|
|
|
adrFailHoldOnTime OBJECT-TYPE
|
|
SYNTAX HoldTime
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Failure hold on time : the time interval during which the
|
|
defect is cleared and the failure is not"
|
|
::= { holdTime 2 }
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
--* EOW
|
|
--*******************************************************************
|
|
EOWClockMode ::= INTEGER
|
|
{
|
|
codirectionnal (0),
|
|
contradirSlave(1),
|
|
contradirMaster(2)
|
|
}
|
|
|
|
EOWType ::= INTEGER
|
|
{
|
|
rsE1 (1),
|
|
rsF1 (2),
|
|
rsOther(3),
|
|
msE2 (4),
|
|
aux (5)
|
|
}
|
|
|
|
eowNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of EOW port in equipment."
|
|
::= {eow 1 }
|
|
|
|
eowTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EowEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of EOW port in equipment."
|
|
::= { eow 2 }
|
|
|
|
eowEntry OBJECT-TYPE
|
|
SYNTAX EowEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular EOW port of the equipment."
|
|
INDEX { eowIndex }
|
|
::= { eowTable 1 }
|
|
|
|
|
|
EowEntry ::= SEQUENCE
|
|
{
|
|
eowIndex INTEGER,
|
|
eowName DisplayString,
|
|
eowSrcType EOWType,
|
|
eowSrcPtr INTEGER,
|
|
eowSinkType EOWType,
|
|
eowSinkPtr INTEGER,
|
|
eowClockMode EOWClockMode
|
|
}
|
|
|
|
|
|
eowIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
EOW port.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to harware."
|
|
::= { eowEntry 1 }
|
|
|
|
eowName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
EOW port entries. "
|
|
::= { eowEntry 2 }
|
|
|
|
eowSrcType OBJECT-TYPE
|
|
SYNTAX EOWType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
interface. Usually the value is the oid of a vc12 or a connection."
|
|
::= { eowEntry 6 }
|
|
|
|
eowSrcPtr OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
interface. Usually the value is the oid of a vc12 or a connection."
|
|
::= { eowEntry 7 }
|
|
|
|
eowSinkType OBJECT-TYPE
|
|
SYNTAX EOWType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
interface. Usually the value is the oid of a vc12 or a connection."
|
|
::= { eowEntry 8 }
|
|
|
|
eowSinkPtr OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
interface. Usually the value is the oid of a vc12 or a connection."
|
|
::= { eowEntry 9 }
|
|
|
|
eowClockMode OBJECT-TYPE
|
|
SYNTAX EOWClockMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select the direction of the two external synchronisation lines."
|
|
::= { eowEntry 10 }
|
|
|
|
END
|