- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
1272 lines
39 KiB
Text
1272 lines
39 KiB
Text
--*******************************************************************
|
|
--* SAGEM SA *
|
|
--*******************************************************************
|
|
--*******************************************************************
|
|
|
|
-- Filename: protection
|
|
-- File type: .mib
|
|
--
|
|
-- Description: SNMPc source Mib file.
|
|
--
|
|
-- Version: 19 11 2002
|
|
--
|
|
-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
|
|
--
|
|
-- Contact: D. Mobuchon, F. Bonnevialle
|
|
--
|
|
-- History:
|
|
--
|
|
-- Name: F.Bonnevialle
|
|
-- Date: 12 12 2000
|
|
-- Desc: original
|
|
--
|
|
-- Name: F.Bonnevialle/S.Laurent
|
|
-- Date: 04 05 2001
|
|
-- Desc: Modification to fit with SDH-ETS MIB
|
|
--
|
|
-- Name: F.Bonnevialle/S.Laurent
|
|
-- Date: 05 06 2001
|
|
-- Desc: Bug correction
|
|
--
|
|
-- Name: J.Thieser
|
|
-- Date: 10 08 01
|
|
-- Desc: modifications for IONOS NMS (SPRing)
|
|
--
|
|
-- Name: F.Bonnevialle
|
|
-- Date: 15 11 2002
|
|
-- Desc: Modification for SilverCreek Compiler
|
|
--
|
|
--*******************************************************************
|
|
--*******************************************************************
|
|
--* Copyright (c) 2002, SAGEM , All rights reserved. *
|
|
--*******************************************************************
|
|
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
-- MIB: PROTECTION-MIB
|
|
--*******************************************************************
|
|
PROTECTION-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--*******************************************************************
|
|
-- IMPORTS
|
|
--*******************************************************************
|
|
|
|
IMPORTS
|
|
sagemDr FROM SAGEM-DR-MIB
|
|
SagemBoolean, Severity FROM EQUIPMENT-MIB
|
|
MODULE-IDENTITY,OBJECT-TYPE FROM SNMPv2-SMI;
|
|
|
|
protection MODULE-IDENTITY
|
|
LAST-UPDATED "9911290000Z"
|
|
ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
|
|
CONTACT-INFO
|
|
" "
|
|
DESCRIPTION
|
|
" This MIB describe protection mechanisms used by SDH equipment"
|
|
::= { sagemDr 130 }
|
|
|
|
-- multiplex section protection
|
|
msp OBJECT IDENTIFIER ::= { protection 10 }
|
|
|
|
-- multiplex section shared protection ring
|
|
msSPRing OBJECT IDENTIFIER ::= { protection 20 }
|
|
|
|
-- sub network connection protection
|
|
sncp OBJECT IDENTIFIER ::= { protection 30 }
|
|
|
|
-- card protection
|
|
cardp OBJECT IDENTIFIER ::= { protection 40 }
|
|
|
|
|
|
--*******************************************************************
|
|
--* Common declarations
|
|
--*******************************************************************
|
|
|
|
TrafficStatus ::= INTEGER
|
|
{
|
|
none(0), -- Future case of a non-implemented link
|
|
working(1),
|
|
protection(2)
|
|
}
|
|
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
--* multiplex section protection (msp)
|
|
--*******************************************************************
|
|
|
|
MspInitiator ::= INTEGER
|
|
{
|
|
unknown(0),
|
|
local(1),
|
|
remote(2)
|
|
}
|
|
|
|
MspFailure ::= INTEGER
|
|
{
|
|
none(0),pam(1),scm(2),otm(4),scmOtm(6)
|
|
}
|
|
|
|
MspPriority ::= INTEGER
|
|
{
|
|
unknown(0),
|
|
highG783(1),
|
|
low(2)
|
|
}
|
|
|
|
MspStatus ::= INTEGER
|
|
{
|
|
lockoutProtection(15),forcedSwitch(14),
|
|
highSF(13),lowSF(12),highSD(11),lowSD(10),
|
|
manualSwitch(8),waitToRestore(6),exercise(4),
|
|
reverseRequest(2),doNotRevert(1),noRequest(0)
|
|
}
|
|
|
|
MspType ::= INTEGER
|
|
{
|
|
unknown(0),
|
|
onePlusOneOptimized(1),
|
|
onePlusOneCompatible(2),
|
|
oneForN(3)
|
|
}
|
|
|
|
MspDirection ::= INTEGER
|
|
{
|
|
unknown(0),
|
|
unidirectionnal(1),
|
|
bidirectionnal(2)
|
|
}
|
|
|
|
MspCommand ::= INTEGER
|
|
{
|
|
clear(0),lw(1),lp(2),fsW(3),fsP(4),msW(5),msP(6),exer(7)
|
|
}
|
|
|
|
|
|
mspNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of multiplex section protection in equipment."
|
|
::= { msp 1 }
|
|
|
|
mspTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MspEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of multiplex section protection in equipment."
|
|
::= { msp 2 }
|
|
|
|
mspEntry OBJECT-TYPE
|
|
SYNTAX MspEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular multiplex section protection of the equipment.
|
|
Each entry is created in using the msTTPTable of the Sdh-Ets MIB."
|
|
INDEX { mspIndex }
|
|
::= { mspTable 1 }
|
|
|
|
|
|
MspEntry ::= SEQUENCE
|
|
{
|
|
mspIndex INTEGER, -- msTTPIndex = mspWorkingPointer
|
|
mspWorkingPointer INTEGER, -- mst working
|
|
mspProtectionPointer INTEGER, -- mst protection
|
|
mspType MspType,
|
|
mspDir MspDirection,
|
|
mspTraffic TrafficStatus,
|
|
mspRevertive SagemBoolean,
|
|
mspWtr INTEGER,
|
|
mspSfSdPriority MspPriority,
|
|
mspSfSdHoldOffTime INTEGER,
|
|
mspCommand MspCommand,
|
|
mspInitiator MspInitiator,
|
|
mspStatus MspStatus,
|
|
mspMonitor SagemBoolean,
|
|
mspFailure MspFailure,
|
|
mspSeverity Severity,
|
|
mspPam Severity,
|
|
mspScm Severity,
|
|
mspOtm Severity
|
|
}
|
|
|
|
|
|
mspIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular multiplex section protection.
|
|
This index is equal to an msTTPIndex(=spiIndex) which gives the interface involved .
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to harware."
|
|
::= { mspEntry 1 }
|
|
|
|
mspWorkingPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on working synchronous port interface side.
|
|
In most equipments, this value cannot be changed and points to
|
|
the working MST it is hard wired with."
|
|
::= { mspEntry 2 }
|
|
|
|
mspProtectionPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on protection synchronous port interface side.
|
|
In most equipments, this value cannot be changed and points to
|
|
the protection MST it is hard wired with.
|
|
When this variable is setting, the protection is created and activated (if it's possible).
|
|
The two considerated sections must have the same Stm Level. "
|
|
::= { mspEntry 3 }
|
|
|
|
mspType OBJECT-TYPE
|
|
SYNTAX MspType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indication of the protection type."
|
|
::= { mspEntry 4 }
|
|
|
|
mspDir OBJECT-TYPE
|
|
SYNTAX MspDirection
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indication of the direction."
|
|
::= { mspEntry 5 }
|
|
|
|
mspTraffic OBJECT-TYPE
|
|
SYNTAX TrafficStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates the protection switch position."
|
|
::= { mspEntry 6 }
|
|
|
|
mspRevertive OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the value is true the msp function is allowed to spontaneously
|
|
switch back to working chanel when it is available.
|
|
If not, the msp can switch back to working chanel only if
|
|
protection chanel fails."
|
|
::= { mspEntry 7 }
|
|
|
|
mspWtr OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (in seconds) the msp function waits before
|
|
considering a chanel as good after a fail."
|
|
::= { mspEntry 8 }
|
|
|
|
mspSfSdPriority OBJECT-TYPE
|
|
SYNTAX MspPriority
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signal Fail and Signal Degrade can be treated according to two set
|
|
of priority. The equipement will send SF and SD events according to
|
|
the value of this field."
|
|
::= { mspEntry 9 }
|
|
|
|
mspSfSdHoldOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The period (in tenth of seconds) during which a
|
|
sf or a Signal Degrade is
|
|
ignored by the MSP switch."
|
|
::= { mspEntry 10 }
|
|
|
|
mspCommand OBJECT-TYPE
|
|
SYNTAX MspCommand
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual or forced commands can be apply to the protection switch.
|
|
The forced and manual switch can be refused or cleared by equipment
|
|
if a higher priority APS command is received or if the protection chanel
|
|
is down.
|
|
When this field is set to manual or forced, the mspTraffic field
|
|
becomes read-write, and a set can be issued to specifie on which
|
|
chanel the command does apply.
|
|
Commands:
|
|
LP (Lockout of Protection)
|
|
LW (Lockout of Working channel)
|
|
FSW (Forced Switch of a Working channel to protection)
|
|
FSP (Forced Switch of a Protection channel to working) case 1+1
|
|
MSW (Manual Switch of a Working channel to protection)
|
|
MSp (Manual Switch of a Protection channel to working) case 1+1
|
|
EXER (EXERcise)
|
|
"
|
|
::= { mspEntry 11 }
|
|
|
|
mspInitiator OBJECT-TYPE
|
|
SYNTAX MspInitiator
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the initiator equipment."
|
|
::= { mspEntry 12 }
|
|
|
|
mspStatus OBJECT-TYPE
|
|
SYNTAX MspStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the initiator equipment status :
|
|
lockoutProtection(15),
|
|
forcedSwitch(14),
|
|
highSF(13),
|
|
lowSF(12),
|
|
highSD(11),
|
|
lowSD(10),
|
|
manualSwitch(8),
|
|
waitToRestore(6),
|
|
exercise(4),
|
|
reverseRequest(2),
|
|
doNotRevert(1),
|
|
noRequest(0) "
|
|
::= { mspEntry 13 }
|
|
|
|
mspMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this multiplex section protection."
|
|
::= { mspEntry 14 }
|
|
|
|
mspFailure OBJECT-TYPE
|
|
SYNTAX MspFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on multiplex section protection."
|
|
::= { mspEntry 15 }
|
|
|
|
mspSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for multiplex section protection."
|
|
::= { mspEntry 16 }
|
|
|
|
mspPam OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Protection Architecture Mismatch failure
|
|
for multiplex section protection."
|
|
::= { mspEntry 20 }
|
|
|
|
mspScm OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Selector Control Mismatch failure
|
|
for multiplex section protection."
|
|
::= { mspEntry 21 }
|
|
|
|
mspOtm OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Operation Type Mismatch failure
|
|
for multiplex section protection."
|
|
::= { mspEntry 22 }
|
|
-- End of multiplex section protection description
|
|
|
|
|
|
--*******************************************************************
|
|
--* multiplex section shared protection ring (ms SpRing)
|
|
--*******************************************************************
|
|
MsSPRingFailure ::= INTEGER
|
|
{
|
|
none(0), ato(1), arv(2), aun (3), ptm (4), mms (5), exr(6)
|
|
}
|
|
|
|
MsSPRingStatus ::= INTEGER
|
|
{
|
|
off(19),lockoutProtection (15), forcedSwitchR (13), sfR (11), sdR (8),
|
|
manualSwitchR (6),
|
|
waitToRestore (5), exerR (3), reverseRequestR (1), noRequest (0)
|
|
}
|
|
|
|
|
|
MsSPRingCommand ::= INTEGER
|
|
{
|
|
clear(16),lpS(15),fsR(13),msR(6),exerR(3),on(20),off(19)
|
|
}
|
|
|
|
MsSPRingID ::= INTEGER
|
|
{
|
|
node0(0), node1(1), node2(2),node3 (3), node4 (4),
|
|
node5(5), node6(6), node7(7),node8 (8), node9 (9),
|
|
node10(10), node11(11), node12(12),node13 (13), node14 (14),
|
|
node15(15), nodeUNK(255)
|
|
}
|
|
|
|
State ::= INTEGER
|
|
{
|
|
off (0),
|
|
idle (1),
|
|
pass (2),
|
|
switch (3),
|
|
unknown (4)
|
|
}
|
|
|
|
msSPRingNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of multiplex section protection in equipment."
|
|
::= { msSPRing 1 }
|
|
|
|
msSPRingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MsSPRingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of multiplex section protection in equipment."
|
|
::= { msSPRing 6 }
|
|
|
|
msSPRingEntry OBJECT-TYPE
|
|
SYNTAX MsSPRingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular multiplex section protection of the equipment.
|
|
Each entry is created in using the msTTPTable of the Sdh-Ets MIB.
|
|
spiIndex gives the interface involved (line east or west)"
|
|
INDEX { msSPRingIndex }
|
|
::= { msSPRingTable 1 }
|
|
|
|
MsSPRingEntry ::= SEQUENCE
|
|
{
|
|
msSPRingIndex INTEGER, -- West index
|
|
msSPRingWestPointer INTEGER, -- vers mst
|
|
msSPRingEastPointer INTEGER, -- vers mst
|
|
msSPRingWtr INTEGER, -- 0-30 min,+/-1min,def 5min
|
|
msSPRingSfSdHoldOffTime INTEGER,
|
|
msSPRingCommandSide INTEGER, -- vers mst
|
|
msSPRingCommand MsSPRingCommand,
|
|
msSPRingInitiator1 MsSPRingID, -- 0..15
|
|
msSPRingInitiator2 MsSPRingID, -- 0..15
|
|
msSPRingNodeState State,
|
|
msSPRingSwitchingSide INTEGER, -- vers mst
|
|
msSPRingWestTraffic TrafficStatus,
|
|
msSPRingEastTraffic TrafficStatus,
|
|
msSPRingWestStatus MsSPRingStatus,
|
|
msSPRingEastStatus MsSPRingStatus,
|
|
msSPRingMonitor SagemBoolean,
|
|
msSPRingFailure MsSPRingFailure,
|
|
msSPRingSeverity Severity,
|
|
msSPRingAto Severity,
|
|
msSPRingArv Severity,
|
|
msSPRingAun Severity,
|
|
msSPRingPtm Severity,
|
|
msSPRingMms Severity,
|
|
msSPRingExr Severity,
|
|
msSPRingSimpleFailure SagemBoolean,
|
|
msSPRingId MsSPRingID
|
|
}
|
|
|
|
msSPRingIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular SPRing = West STM index."
|
|
::= { msSPRingEntry 1 }
|
|
|
|
msSPRingWestPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on synchronous port interface side.
|
|
In most equipments, this value cannot be changed and points to
|
|
the West MST it is hard wired with."
|
|
::= { msSPRingEntry 2 }
|
|
|
|
msSPRingEastPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on synchronous port interface side.
|
|
In most equipments, this value cannot be changed and points to
|
|
the East MST it is hard wired with.
|
|
When this variable is setting, the protection is created and activated (if it's possible).
|
|
The two considerated sections must have the same Stm Level."
|
|
::= { msSPRingEntry 3 }
|
|
|
|
msSPRingWtr OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (in seconds) the spring function waits before
|
|
considering a chanel as good after a fail."
|
|
::= { msSPRingEntry 5 }
|
|
|
|
msSPRingSfSdHoldOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The period (in tenth of seconds) during which a
|
|
sf or a Signal Degrade is ignored by the SPRing switch."
|
|
::= { msSPRingEntry 6 }
|
|
|
|
msSPRingCommandSide OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Side of the command"
|
|
::= { msSPRingEntry 7 }
|
|
|
|
msSPRingCommand OBJECT-TYPE
|
|
SYNTAX MsSPRingCommand
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual or forced commands can be apply to the protection switch.
|
|
"
|
|
::= { msSPRingEntry 8 }
|
|
|
|
msSPRingInitiator1 OBJECT-TYPE
|
|
SYNTAX MsSPRingID
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference(ID) to the equipment that initiate the SWITCH; this is mainly the Master
|
|
when the equipment is in SWITCH state; in some case like bidirectional SF both equipment
|
|
of the couple equipment are Master.
|
|
In PASS state Master and Slave are undeterminated"
|
|
::= { msSPRingEntry 10 }
|
|
|
|
msSPRingInitiator2 OBJECT-TYPE
|
|
SYNTAX MsSPRingID
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference(ID) to the equipment that respond to the SWITCH; this is mainly the Slave
|
|
when the equipment is in SWITCH state; in some case like bidirectional SF both equipment
|
|
of the couple equipment are Master.
|
|
In PASS state Master and Slave are undeterminated"
|
|
|
|
::= { msSPRingEntry 11 }
|
|
|
|
msSPRingNodeState OBJECT-TYPE
|
|
SYNTAX State
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { msSPRingEntry 29 }
|
|
|
|
msSPRingSwitchingSide OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Switching SideSide"
|
|
::= { msSPRingEntry 30 }
|
|
|
|
msSPRingWestTraffic OBJECT-TYPE
|
|
SYNTAX TrafficStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates the protection switch position."
|
|
::= { msSPRingEntry 31 }
|
|
|
|
msSPRingEastTraffic OBJECT-TYPE
|
|
SYNTAX TrafficStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates the protection switch position."
|
|
::= { msSPRingEntry 32 }
|
|
|
|
msSPRingWestStatus OBJECT-TYPE
|
|
SYNTAX MsSPRingStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the local status:
|
|
OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8),
|
|
manualSwitch-R(6),
|
|
waitToRestore(5),exer-R(3),noRequest(0)"
|
|
::= { msSPRingEntry 33 }
|
|
|
|
msSPRingEastStatus OBJECT-TYPE
|
|
SYNTAX MsSPRingStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the local status:
|
|
OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8),
|
|
manualSwitch-R(6),
|
|
waitToRestore(5),exer-R(3),noRequest(0)"
|
|
::= { msSPRingEntry 34 }
|
|
|
|
|
|
msSPRingMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this multiplex section protection."
|
|
::= { msSPRingEntry 12 }
|
|
|
|
msSPRingFailure OBJECT-TYPE
|
|
SYNTAX MsSPRingFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on multiplex section protection"
|
|
::= { msSPRingEntry 13 }
|
|
|
|
msSPRingSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for multiplex section protection."
|
|
::= { msSPRingEntry 14 }
|
|
|
|
msSPRingAto OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with APS Time Out failure failure
|
|
for MS-SPRing."
|
|
::= { msSPRingEntry 21 }
|
|
|
|
msSPRingArv OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with APS Rules Violation failure failure
|
|
for MS-SPRing."
|
|
::= { msSPRingEntry 22 }
|
|
|
|
msSPRingAun OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with APS Unknown Node failure failure
|
|
for MS-SPRing."
|
|
::= { msSPRingEntry 23 }
|
|
|
|
msSPRingPtm OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Potential Traffic Misconnection failure
|
|
for MS-SPRing."
|
|
::= { msSPRingEntry 24 }
|
|
|
|
msSPRingMms OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Mutiple Multiplex Section Fail failure
|
|
for MS-SPRing."
|
|
::= { msSPRingEntry 25 }
|
|
|
|
msSPRingExr OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with EXeRcise failure
|
|
for MS-SPRing."
|
|
::= { msSPRingEntry 26 }
|
|
|
|
msSPRingSimpleFailure OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicate if simple or multi ring failure must be considerated"
|
|
::= { msSPRingEntry 27 }
|
|
|
|
msSPRingId OBJECT-TYPE
|
|
SYNTAX MsSPRingID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ring Identifier of the equipement"
|
|
::= { msSPRingEntry 28 }
|
|
|
|
--*******************************************************************
|
|
msSPRingTopoMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MsSPRingTopoMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Topology Map of the ring = West STM index + Val (1<=Val<=16)."
|
|
::= { msSPRing 11 }
|
|
|
|
msSPRingTopoMapEntry OBJECT-TYPE
|
|
SYNTAX MsSPRingTopoMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular entry of the ring topology map."
|
|
INDEX { msSPRingTopoMapIndex }
|
|
::= { msSPRingTopoMapTable 1 }
|
|
|
|
-- 16 entries in this table
|
|
MsSPRingTopoMapEntry ::= SEQUENCE
|
|
{
|
|
msSPRingTopoMapIndex INTEGER,
|
|
msSPRingTopoMapID MsSPRingID
|
|
}
|
|
|
|
msSPRingTopoMapIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"index"
|
|
::= { msSPRingTopoMapEntry 1 }
|
|
|
|
msSPRingTopoMapID OBJECT-TYPE
|
|
SYNTAX MsSPRingID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"identifier of the node"
|
|
::= { msSPRingTopoMapEntry 2 }
|
|
|
|
|
|
--*******************************************************************
|
|
MisconMapType ::= INTEGER
|
|
{
|
|
terminated(1), passedThrough (2)
|
|
}
|
|
MsSPRingSide ::= INTEGER
|
|
{
|
|
west(0),east(1), unknown(2)
|
|
}
|
|
|
|
msSPRingMisconMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MsSPRingMisconMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Connectivity (misconnection) Map of the ring."
|
|
::= { msSPRing 21 }
|
|
|
|
msSPRingMisconMapEntry OBJECT-TYPE
|
|
SYNTAX MsSPRingMisconMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular entry of the ring connectivity (misconnection) map.
|
|
All entries are created after setting the msSPRingWestPointer."
|
|
INDEX { msSPRingMisconMapIndex }
|
|
::= { msSPRingMisconMapTable 1 }
|
|
|
|
-- 8 West + 8 East entries in this table for each SPRing
|
|
MsSPRingMisconMapEntry ::= SEQUENCE
|
|
{
|
|
msSPRingMisconMapIndex INTEGER,
|
|
msSPRingMisconMapSide MsSPRingSide,
|
|
msSPRingMisconMapIn MsSPRingID,
|
|
msSPRingMisconMapOut MsSPRingID ,
|
|
msSPRingMisconMapTimeSlot INTEGER,
|
|
msSPRingMisconMapType MisconMapType,
|
|
msSPRingMisconMapLOAccess SagemBoolean
|
|
}
|
|
|
|
msSPRingMisconMapIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index = West STM index + Val (1<=Val<=16)
|
|
ADR2500c : val = 1 to 8 for West and 9 to 16 for East"
|
|
::= { msSPRingMisconMapEntry 1 }
|
|
|
|
msSPRingMisconMapSide OBJECT-TYPE
|
|
SYNTAX MsSPRingSide
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Side (WestPointer/msSPRingEast) of the interface that supports the AU4"
|
|
::= { msSPRingMisconMapEntry 2 }
|
|
|
|
msSPRingMisconMapIn OBJECT-TYPE
|
|
SYNTAX MsSPRingID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Node of the ring where the Au4 traffic enters the ring"
|
|
::= { msSPRingMisconMapEntry 3 }
|
|
|
|
msSPRingMisconMapOut OBJECT-TYPE
|
|
SYNTAX MsSPRingID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Node of the ring where the Au4 traffic exits the ring"
|
|
::= { msSPRingMisconMapEntry 4 }
|
|
|
|
msSPRingMisconMapTimeSlot OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time Slot assignment for the AU4"
|
|
::= { msSPRingMisconMapEntry 5 }
|
|
|
|
msSPRingMisconMapType OBJECT-TYPE
|
|
SYNTAX MisconMapType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the value is equal to terminated, the traffic in the ring is inserted
|
|
or extracted at this node.
|
|
If the value is equal to passedThrough the traffic only cross the node"
|
|
::= { msSPRingMisconMapEntry 6 }
|
|
|
|
msSPRingMisconMapLOAccess OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True if the AU4 is accessed at LO layers somewhere in the ring"
|
|
::= { msSPRingMisconMapEntry 7 }
|
|
|
|
--*******************************************************************
|
|
msSPRingNUTTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MsSPRingNUTEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Topology Map of the ring."
|
|
::= { msSPRing 31 }
|
|
|
|
msSPRingNUTEntry OBJECT-TYPE
|
|
SYNTAX MsSPRingNUTEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular entry of the ring topology map."
|
|
INDEX { msSPRingNUTIndex }
|
|
::= { msSPRingNUTTable 1 }
|
|
|
|
-- 8 entries in this table
|
|
MsSPRingNUTEntry ::= SEQUENCE
|
|
{
|
|
msSPRingNUTIndex INTEGER, -- time slot
|
|
msSPRingNUTisNut SagemBoolean
|
|
}
|
|
|
|
msSPRingNUTIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AU4 index = West STM index + Val (Val = working timeSlot; 1<=Val<=8)"
|
|
::= { msSPRingNUTEntry 1 }
|
|
|
|
msSPRingNUTisNut OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Define if the traffic is used for NUT Traffic"
|
|
::= { msSPRingNUTEntry 2 }
|
|
|
|
|
|
-- End of multiplex section shared protection ring (ms spRing)
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
--* sncp
|
|
--*******************************************************************
|
|
LinkType ::= INTEGER
|
|
{
|
|
unknown(0),
|
|
au(1),
|
|
au4c(2),
|
|
au16c(3),
|
|
tu3(10),
|
|
tu12(20)
|
|
}
|
|
|
|
TriggerCriterion ::= INTEGER
|
|
{
|
|
none(0),
|
|
sncI(1),
|
|
sncN(2),
|
|
sncIRdi(3),
|
|
sncNRdi(4)
|
|
}
|
|
|
|
SNCStateProcess ::= INTEGER
|
|
{
|
|
nrnormal(0),
|
|
nrsecours(1),
|
|
wtr(2),
|
|
dontRev(3),
|
|
mssecours(4),
|
|
msnormal(5),
|
|
sdnormal(6),
|
|
sdsecours(7),
|
|
sfnormal(8),
|
|
fssecours(9),
|
|
sfsecours(10),
|
|
fsnormal(11),
|
|
lockout(12)
|
|
-- msRDInormal(11),
|
|
-- sfmsRDInormal(12),
|
|
-- sdmsRDInormal(13),
|
|
-- msRDIsecours(16),
|
|
-- sfmsRDIsecours (17),
|
|
-- sdmsRDIsecours(18)
|
|
}
|
|
|
|
SNCCommand ::= INTEGER
|
|
{
|
|
clear(0),
|
|
manualWorking(1),
|
|
manualProtection(2),
|
|
forcedWorking(3),
|
|
forcedProtection(4),
|
|
lockout(5),
|
|
off(19),
|
|
on(20)
|
|
}
|
|
|
|
sncNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of snc in equipment."
|
|
::= { sncp 1 }
|
|
|
|
sncTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SncEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of snc protection in equipment."
|
|
::= { sncp 2 }
|
|
|
|
sncEntry OBJECT-TYPE
|
|
SYNTAX SncEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular SNC protection which is created in using the linkTable of the Xconnection MIB."
|
|
INDEX { sncIndex }
|
|
::= { sncTable 1 }
|
|
|
|
SncEntry ::=
|
|
SEQUENCE {
|
|
sncIndex INTEGER, -- linkIndex
|
|
sncLinkType LinkType,
|
|
sncCTPSink INTEGER,
|
|
sncCTPSourceW INTEGER,
|
|
sncCTPSourceP INTEGER,
|
|
sncTrafficStatus TrafficStatus,
|
|
sncWorkingTriggerType TriggerCriterion,
|
|
sncProtectionTriggerType TriggerCriterion,
|
|
sncRevertive SagemBoolean,
|
|
sncWtr INTEGER,
|
|
sncStateProcess SNCStateProcess,
|
|
sncHoldOffTime INTEGER,
|
|
sncCommand SNCCommand
|
|
|
|
}
|
|
|
|
sncIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sncIndex = 1000*sncType + sncTTPSink = linkIndex"
|
|
::= { sncEntry 1 }
|
|
|
|
sncCTPSink OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field is the index of the Output Connection to which
|
|
an snc function is applied."
|
|
::= { sncEntry 2 }
|
|
|
|
sncLinkType OBJECT-TYPE
|
|
SYNTAX LinkType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trail level of the connection"
|
|
::= { sncEntry 3 }
|
|
|
|
sncCTPSourceW OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates the Working Input Connection Point which
|
|
composes the protection link of the Output Connection Point (sncIndex)."
|
|
::= { sncEntry 4 }
|
|
|
|
sncCTPSourceP OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates the Protected Input Connection Point which
|
|
composes the protection link of the Output Connection Point (sncIndex).
|
|
When this variable is setting, the protection is created and activated (if it's possible). "
|
|
::= { sncEntry 5 }
|
|
|
|
sncTrafficStatus OBJECT-TYPE
|
|
SYNTAX TrafficStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field indicates the Protection unit switch position."
|
|
::= { sncEntry 6}
|
|
|
|
sncWorkingTriggerType OBJECT-TYPE
|
|
SYNTAX TriggerCriterion
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The value of this field is the criterion to trigger a switch for the Working Input
|
|
Connection Point.SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC12/VC3 ,
|
|
AU-AIS/AU-LOP for VC4 and , by extension, ppiLOS and ppiAIS for pdh inputs.
|
|
SNC/N uses also SD criterion for switching: SD-V5 for VC12,
|
|
SD-B3 for VC3/VC4.
|
|
SNC+LAN adds MS-RDI as switching criterion for LAN connection.
|
|
NONE means that just board extractions and some board failures activate switching."
|
|
::= { sncEntry 8 }
|
|
|
|
sncProtectionTriggerType OBJECT-TYPE
|
|
SYNTAX TriggerCriterion
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The value of this field is the criterion to trigger a switch for the Protection Input
|
|
Connection Point. SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC12/VC3 ,
|
|
AU-AIS/AU-LOP for VC4 and , by extension, ppiLOS and ppiAIS for pdh inputs.
|
|
SNC/N uses also SD criterion for switching: SD-V5 for VC12,
|
|
SD-B3 for VC3/VC4.
|
|
SNC+LAN adds MS-RDI as switching criterion for LAN connection.
|
|
NONE means that just board extractions and some board failures activate switching."
|
|
::= { sncEntry 9 }
|
|
|
|
|
|
sncRevertive OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the value is true the Protection unit function is allowed
|
|
to spontaneously switch back to working chanel when it is available.
|
|
If not, the snc can switch back to working chanel only if
|
|
protection chanel fails."
|
|
::= { sncEntry 20 }
|
|
|
|
sncWtr OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (in seconds) the Protection unit function waits before
|
|
considering a chanel as good after a fail."
|
|
::= { sncEntry 21 }
|
|
|
|
sncStateProcess OBJECT-TYPE
|
|
SYNTAX SNCStateProcess
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The value of this field indicates the state of the snc protection process."
|
|
::= { sncEntry 22 }
|
|
|
|
|
|
sncHoldOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time in tenth of seconds during which a protection trigger criterion is
|
|
ignored."
|
|
::= { sncEntry 23 }
|
|
|
|
sncCommand OBJECT-TYPE
|
|
SYNTAX SNCCommand
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual or forced commands can be apply to the protection unit.
|
|
The forced and manual switch can be refused or cleared by equipment
|
|
if a higher priority evenement is received or if the protection chanel
|
|
is down."
|
|
::= { sncEntry 24 }
|
|
|
|
|
|
--*******************************************************************
|
|
--* Card Protection
|
|
--*******************************************************************
|
|
|
|
CardpFamily ::= INTEGER
|
|
{
|
|
none(0),
|
|
switch (1)
|
|
}
|
|
|
|
CardpCommand ::= INTEGER
|
|
{
|
|
clear(0),
|
|
manualSwitch (1)
|
|
}
|
|
|
|
CardpStatus ::= INTEGER
|
|
{
|
|
notSwitched(0),
|
|
manualSwitch (1),
|
|
automaticSwitch (2)
|
|
}
|
|
|
|
cardpNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of card protections in equipment."
|
|
::= { cardp 1 }
|
|
|
|
cardpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CardpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of card protections in equipment."
|
|
::= { cardp 2 }
|
|
|
|
cardpEntry OBJECT-TYPE
|
|
SYNTAX CardpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular card protection which is created in using the boardTable of the Shelf MIB."
|
|
INDEX { cardpIndex }
|
|
::= { cardpTable 1 }
|
|
|
|
CardpEntry ::=
|
|
SEQUENCE {
|
|
cardpIndex INTEGER, -- working BoardIndex
|
|
cardpBoardFamily CardpFamily,
|
|
cardpReliefIndex INTEGER, -- protection BoardIndex
|
|
cardpTrafficStatus TrafficStatus,
|
|
cardpCommand CardpCommand,
|
|
cardpStatus CardpStatus
|
|
}
|
|
|
|
cardpIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cardpIndex = boardIndex in the Shelf Mib.
|
|
This index points to the working board."
|
|
::= { cardpEntry 1 }
|
|
|
|
cardpBoardFamily OBJECT-TYPE
|
|
SYNTAX CardpFamily
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field indicates the family of board concerned by the protection."
|
|
::= { cardpEntry 2 }
|
|
|
|
cardpReliefIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the relief card. It must be an existing index in the boardTable of Shelf Mib.
|
|
The relief card and the protected Card must below to the same familly.
|
|
When this variable is setting, the protection is created and activated (if it's possible)."
|
|
::= { cardpEntry 3 }
|
|
|
|
cardpTrafficStatus OBJECT-TYPE
|
|
SYNTAX TrafficStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indication of the protection switch position."
|
|
::= { cardpEntry 4 }
|
|
|
|
cardpCommand OBJECT-TYPE
|
|
SYNTAX CardpCommand
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual commands can be apply to the protection unit.
|
|
The manual switch can be refused or cleared by equipment
|
|
if a higher priority evenement is received or if the protection chanel
|
|
is down."
|
|
::= { cardpEntry 5 }
|
|
|
|
cardpStatus OBJECT-TYPE
|
|
SYNTAX CardpStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indication of the current protection status"
|
|
::= { cardpEntry 6 }
|
|
|
|
|
|
END
|
|
|
|
|