- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
439 lines
18 KiB
Text
439 lines
18 KiB
Text
-- ==================================================================
|
|
-- Copyright (C) 2002 by HUAWEI TECHNOLOGIES. All rights reserved.
|
|
--
|
|
-- Description: HUAWEI RPR extend MIB
|
|
-- Reference:
|
|
-- Version: V1.0
|
|
-- History:
|
|
-- ==================================================================
|
|
|
|
HUAWEI-RPR-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
hwDatacomm
|
|
FROM HUAWEI-MIB
|
|
rprIfIndex, rprIfWrapConfig, rprIfRingOperModes, rprIfCurrentStatus, rprSpanIfIndex,
|
|
rprSpanId, rprSpanTotalRingletReservedRate, rprTopoImageIfIndex, rprTopoImageMacAddress, rprTopoImageStationIfIndex,
|
|
rprTopoImageRinglet0Hops, rprTopoImageRinglet1Hops, rprTopoImageWestProtectionStatus, rprTopoImageEastProtectionStatus, rprTopoImageStatus,
|
|
RprSpan
|
|
FROM IEEE-802DOT17-RPR-MIB
|
|
ifIndex, ifPhysAddress, ifName, InterfaceIndex
|
|
FROM IF-MIB
|
|
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI;
|
|
|
|
|
|
hwRPR MODULE-IDENTITY
|
|
LAST-UPDATED "200601090000Z" -- January 09, 2006 at 00:00 GMT
|
|
ORGANIZATION
|
|
"Huawei Technologies co.,Ltd."
|
|
CONTACT-INFO
|
|
" R&D BeiJing, Huawei Technologies co.,Ltd.
|
|
Huawei Bld.,NO.3 Xinxi Rd.,
|
|
Shang-Di Information Industry Base,
|
|
Hai-Dian District Beijing P.R. China
|
|
Zip:100085
|
|
Http://www.huawei.com
|
|
E-mail:support@huawei.com "
|
|
DESCRIPTION
|
|
"The HUAWEI-RPR-TRAP-MIB contains objects to
|
|
Monitor the RPR TRAPs.
|
|
|
|
*********************************
|
|
RPR TRAP
|
|
**********************************
|
|
This RPR TRAP consists of the following TRAPs:
|
|
1 : hwRPRexcessReservedRateDefect
|
|
2 : hwRPRprotMisconfigDefect
|
|
3 : hwRPRtopoChange
|
|
4 : hwRPRtopoInvalidDefect
|
|
5 : hwRPRduplicateMacAddressDefect
|
|
6 : hwRPRtopoInstabilityDefect
|
|
7 : hwRPRtopoStabilityRestore
|
|
8 : hwRPRPhyIfEventTrap
|
|
9 : hwRPRLogicIfEventTrap
|
|
"
|
|
::= { hwDatacomm 36 }
|
|
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
hwRPRObjects OBJECT IDENTIFIER ::= { hwRPR 1 }
|
|
|
|
hwRPRIfEventTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwRPRIfEventEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of interface event information."
|
|
::= { hwRPRObjects 1 }
|
|
|
|
hwRPRIfEventEntry OBJECT-TYPE
|
|
SYNTAX HwRPRIfEventEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface event information Entry."
|
|
INDEX { hwRPRLogicIfIndex, hwRPRLogicIfSpanId }
|
|
::= { hwRPRIfEventTable 1 }
|
|
|
|
HwRPRIfEventEntry ::=
|
|
SEQUENCE {
|
|
hwRPRLogicIfIndex
|
|
InterfaceIndex,
|
|
hwRPRLogicIfSpanId
|
|
RprSpan,
|
|
hwRPRLogicIfEvent
|
|
INTEGER,
|
|
hwRPRPhyIfEvent
|
|
INTEGER
|
|
}
|
|
|
|
hwRPRLogicIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of this RPR logic interface."
|
|
::= { hwRPRIfEventEntry 1 }
|
|
|
|
hwRPRLogicIfSpanId OBJECT-TYPE
|
|
SYNTAX RprSpan
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SpanId of this RPR logic interface."
|
|
::= { hwRPRIfEventEntry 2 }
|
|
|
|
hwRPRLogicIfEvent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
sd(1),
|
|
sf(2),
|
|
mateerr(3)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of logic interface event.
|
|
SD indicates that SDH Signal of the RPR logic interface degrades;
|
|
SF indicates that SDH Signal of the RPR logic interface fails;
|
|
MATEERR indicates that mate cable error caused by mate cable of
|
|
the RPR physical interface is linked incorrect;
|
|
"
|
|
::= { hwRPRIfEventEntry 3 }
|
|
|
|
hwRPRPhyIfEvent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
sdHFramerSDst(1),
|
|
sdHFramerSFst(2),
|
|
sdHFramerLOSst(3),
|
|
sdHFramerLOFst(4),
|
|
sdHFramerRDIst(5),
|
|
sdHFramerAISst(6),
|
|
sdHFramerREIst(7),
|
|
miscabling(8),
|
|
keepalive(9),
|
|
mateState(10)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of physical interface event.
|
|
SDHFramerSDst indicates that SDH Signal of the RPR physical interface degrades;
|
|
SDHFramerSFst indicates that SDH Signal of the RPR physical interface fails;
|
|
SDHFramerLOSst indicates that SDH Signal of the RPR physical interface loses;
|
|
SDHFramerLOFst indicates that SDH framer of the RPR physical interface loses;
|
|
SDHFramerRDIst indicates that remote Defect Indication ;
|
|
SDHFramerAISst indicates that alarm Indication Signal;
|
|
SDHFramerREIst indicates that remote ErrorIndication;
|
|
Miscabling indicates that cable of the RPR physical interface is linked incorrect;
|
|
Keepalive indicates that an exchange of messages allowing verification
|
|
that communication between stations is not active;
|
|
MateState indicates that mate cable of the RPR physical interface is linked incorrect.
|
|
"
|
|
::= { hwRPRIfEventEntry 4 }
|
|
|
|
hwRPRIfConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwRPRIfConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of RPR logic interface configuration information."
|
|
::= { hwRPRObjects 2 }
|
|
|
|
hwRPRIfConfigEntry OBJECT-TYPE
|
|
SYNTAX HwRPRIfConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RPR interface Configuration entry."
|
|
INDEX { hwRPRIfConfigIfIndex }
|
|
::= { hwRPRIfConfigTable 1 }
|
|
|
|
HwRPRIfConfigEntry ::=
|
|
SEQUENCE {
|
|
hwRPRIfConfigIfIndex InterfaceIndex,
|
|
hwRPRLogicIfTotalBandWidth INTEGER
|
|
}
|
|
hwRPRIfConfigIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of this RPR logic interface."
|
|
::= { hwRPRIfConfigEntry 1 }
|
|
hwRPRLogicIfTotalBandWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
bandwidth1000(1000),
|
|
bandwidth2488(2488),
|
|
bandwidth10000(10000)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total bandwidth of this RPR logic interface."
|
|
::= { hwRPRIfConfigEntry 2 }
|
|
|
|
hwRPRTraps OBJECT IDENTIFIER ::= { hwRPR 2 }
|
|
|
|
hwRPRexcessReservedRateDefect NOTIFICATION-TYPE
|
|
OBJECTS { rprSpanTotalRingletReservedRate }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This defect indicates that the amount of reserved
|
|
bandwidth on a ringlet exceeds the available LINK_RATE.
|
|
When an excess reserved rate defect is present,
|
|
a notification may be generated.
|
|
"
|
|
::= { hwRPRTraps 1 }
|
|
|
|
hwRPRprotMisconfigDefect NOTIFICATION-TYPE
|
|
OBJECTS { rprIfWrapConfig, rprIfRingOperModes }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical severity defect that indicates the presence
|
|
of mismatched-protection-configuration stations, based
|
|
on the value returned by MismatchedProtection().
|
|
When a protection configuration defect is present
|
|
on the station, a notification may be generated.
|
|
"
|
|
::= { hwRPRTraps 2 }
|
|
|
|
hwRPRtopoChange NOTIFICATION-TYPE
|
|
OBJECTS { rprTopoImageStationIfIndex, rprTopoImageStatus, rprTopoImageWestProtectionStatus, rprTopoImageEastProtectionStatus, rprIfCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When an topology change is present,
|
|
a notification may be generated..
|
|
"
|
|
::= { hwRPRTraps 3 }
|
|
|
|
hwRPRtopoInvalidDefect NOTIFICATION-TYPE
|
|
OBJECTS { ifPhysAddress, rprIfCurrentStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical severity defect indicating that an
|
|
invalid entry has been found within the scope
|
|
of the topology,the stations on the ring excess
|
|
the MAX_STATIONS or the local station has one
|
|
or more duplicate secondary MAC addresses. When
|
|
a topology entry invalid defect ,exceeing MaxStations
|
|
or duplicate secondary MAC addresses is present,
|
|
a notification may be generated.
|
|
"
|
|
::= { hwRPRTraps 4 }
|
|
|
|
hwRPRduplicateMacAddressDefect NOTIFICATION-TYPE
|
|
OBJECTS { ifPhysAddress, rprTopoImageRinglet0Hops, rprTopoImageRinglet1Hops }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A critical severity defect indicating that a
|
|
duplicateMacAddress has been found on the ring.
|
|
When a duplicateMacAddress defect is present,
|
|
a notification may be generated.
|
|
"
|
|
::= { hwRPRTraps 5 }
|
|
|
|
hwRPRtopoInstabilityDefect NOTIFICATION-TYPE
|
|
OBJECTS { ifPhysAddress }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The critical severity Instable topology defect.
|
|
When an Instable topology defect is present,
|
|
a notification may be generated.
|
|
"
|
|
::= { hwRPRTraps 6 }
|
|
|
|
hwRPRtopoStabilityRestore NOTIFICATION-TYPE
|
|
OBJECTS { ifPhysAddress }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The critical severity Instable topology restore.
|
|
When an stable topology is present,
|
|
a notification may be generated.
|
|
"
|
|
::= { hwRPRTraps 7 }
|
|
|
|
hwRPRPhyIfEventTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwRPRLogicIfIndex, hwRPRLogicIfSpanId, hwRPRPhyIfEvent }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The critical severity physical interface defect.
|
|
When an physical interface defect is present,
|
|
a notification may be generated.
|
|
"
|
|
::= { hwRPRTraps 8 }
|
|
|
|
hwRPRLogicIfEventTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwRPRLogicIfIndex, hwRPRLogicIfSpanId, hwRPRLogicIfEvent }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The critical severity Logic interface defect.
|
|
When an logic interface defect that caused
|
|
by physical interface event is present,
|
|
a notification may be generated.
|
|
"
|
|
::= { hwRPRTraps 9 }
|
|
|
|
hwRPRNodeConErr NOTIFICATION-TYPE
|
|
OBJECTS { ifName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"On RPR ring, to detect the connection, a kind of packet
|
|
is send between neighbor RPR nodes, This kind of packet
|
|
is SC(Single-Choke) packet, If a node cannot receive SC
|
|
packet from neighbor node in KEEPALIVE time, then there
|
|
is failure between the two nodes. When happened, auto protection
|
|
is executed by software.!"
|
|
::= { hwRPRTraps 10 }
|
|
|
|
hwRPRNodeConErrResume NOTIFICATION-TYPE
|
|
OBJECTS { ifName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"On RPR ring, to detect the connection, a kind of packet
|
|
is send between neighbor RPR nodes, This kind of packet
|
|
is SC(Single-Choke) packet, If a node cannot receive SC
|
|
packet from neighbor node in KEEPALIVE time, then there
|
|
is failure between the two nodes. When failure is resumed
|
|
, this notification is sent.!"
|
|
::= { hwRPRTraps 11 }
|
|
|
|
hwRPRNodeMisCabling NOTIFICATION-TYPE
|
|
OBJECTS { ifName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Optical fiber is connected in error. i.e the east direction
|
|
of one node is connected with east direction of another node,
|
|
or the west direction of one node is connected with west direction
|
|
of another node!"
|
|
::= { hwRPRTraps 12 }
|
|
|
|
hwRPRNodeMisCablingResume NOTIFICATION-TYPE
|
|
OBJECTS { ifName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"when phenomena that Optical fiber is connected in error disappears,
|
|
this notification is sent!"
|
|
::= { hwRPRTraps 13 }
|
|
|
|
hwRPRMateErr NOTIFICATION-TYPE
|
|
OBJECTS { ifName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In double RPR operating mode, east and west directions
|
|
of one rpr node lay on two RPR cards, These two cards are
|
|
internally conntected by Gigaibit-ethernet, which is called
|
|
MATE interface. The RPR nodes cannot work normaly under
|
|
condition of MATE error.!"
|
|
::= { hwRPRTraps 14 }
|
|
|
|
hwRPRMateErrResume NOTIFICATION-TYPE
|
|
OBJECTS { ifName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In double RPR operating mode, east and west directions
|
|
of one rpr node lay on two RPR cards, These two cards are
|
|
internally conntected by Gigaibit-ethernet, which is called
|
|
MATE interface. The RPR nodes cannot work normaly under
|
|
condition of MATE error.when MATE error is resumed ,this
|
|
notification is sent!"
|
|
::= { hwRPRTraps 15 }
|
|
|
|
hwRPRLOS NOTIFICATION-TYPE
|
|
OBJECTS { ifName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"On RPR physical layer, link connection is detected
|
|
through physical singal. When can't receive physical
|
|
singal, then local node from neighbor node, LOS(lost of signal)
|
|
alarm is report, auto protection is executed by software.!"
|
|
::= { hwRPRTraps 16 }
|
|
|
|
hwRPRLOSResume NOTIFICATION-TYPE
|
|
OBJECTS { ifName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"On RPR physical layer, link connection is detected
|
|
through physical singal. When can't receive physical
|
|
singal, then local node from neighbor node, LOS(lost of signal)
|
|
alarm is report, auto protection is executed by software.when LOS
|
|
is resumed,this notification is sent"
|
|
::= { hwRPRTraps 17 }
|
|
|
|
hwRPRTrapConformance OBJECT IDENTIFIER ::= { hwRPR 3 }
|
|
|
|
hwRPRTrapCompliances OBJECT IDENTIFIER ::= { hwRPRTrapConformance 1 }
|
|
|
|
hwRPRTrapCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities that implement
|
|
RPRTRAP on a router.
|
|
"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { hwRPRIfEventGroup, hwRPRTrapGroup }
|
|
::= { hwRPRTrapCompliances 1 }
|
|
|
|
hwRPRTrapGroups OBJECT IDENTIFIER ::= { hwRPRTrapConformance 2 }
|
|
|
|
hwRPRIfEventGroup OBJECT-GROUP
|
|
OBJECTS { hwRPRLogicIfIndex, hwRPRLogicIfSpanId, hwRPRPhyIfEvent, hwRPRLogicIfEvent }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"provide RPRTRAP objects configuration information. "
|
|
::= { hwRPRTrapGroups 1 }
|
|
|
|
hwRPRTrapGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { hwRPRexcessReservedRateDefect, hwRPRprotMisconfigDefect, hwRPRtopoChange, hwRPRtopoInvalidDefect, hwRPRduplicateMacAddressDefect,
|
|
hwRPRtopoInstabilityDefect, hwRPRtopoStabilityRestore, hwRPRPhyIfEventTrap, hwRPRLogicIfEventTrap, hwRPRNodeConErr,
|
|
hwRPRNodeConErrResume, hwRPRNodeMisCabling, hwRPRNodeMisCablingResume, hwRPRMateErr, hwRPRMateErrResume,
|
|
hwRPRLOS, hwRPRLOSResume }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Required objects to provide RPRTRAP objects configuration
|
|
information. "
|
|
::= { hwRPRTrapGroups 2 }
|
|
|
|
hwRPRIfConfigGroup OBJECT-GROUP
|
|
OBJECTS { hwRPRLogicIfTotalBandWidth }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { hwRPRTrapGroups 3 }
|
|
|
|
|
|
END
|
|
|
|
--
|
|