- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
252 lines
7.4 KiB
Text
252 lines
7.4 KiB
Text
-- =================================================================
|
|
-- Copyright (C) 2009 by HUAWEI TECHNOLOGIES. All rights reserved
|
|
--
|
|
-- Description: HUAWEI HTTP MIB, this mib will maintain information of HTTP
|
|
-- protocol for datacomm product.
|
|
-- Reference:
|
|
-- Version: V1.00
|
|
-- History:
|
|
--
|
|
-- V1.00 2009-03-27 initial version
|
|
-- =================================================================
|
|
HUAWEI-HTTP-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
DateAndTime
|
|
FROM SNMPv2-TC
|
|
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32,OBJECT-IDENTITY,
|
|
IpAddress, Unsigned32, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
|
|
EnabledStatus
|
|
FROM P-BRIDGE-MIB
|
|
|
|
hwDatacomm
|
|
FROM HUAWEI-MIB;
|
|
|
|
hwHttpMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200903271630Z" -- July 15, 2008 at 14:30 GMT
|
|
ORGANIZATION
|
|
"Huawei Technologies co.,Ltd."
|
|
CONTACT-INFO
|
|
"R&D NanJing, Huawei Technologies co.,Ltd.
|
|
High hope mansion,
|
|
Baixia road,
|
|
Nanjing city
|
|
Zip:100085
|
|
Http://www.huawei.com
|
|
E-mail:support@huawei.com
|
|
Zip:100000
|
|
"
|
|
DESCRIPTION
|
|
"This file is a HTTP MIB. It provides the functions such as
|
|
globally enabling or disabling the HTTP service, configuring the global
|
|
port number, showing http server and users information."
|
|
::= { hwDatacomm 192 }
|
|
|
|
-- ============================================================================
|
|
-- Node definitions
|
|
-- ============================================================================
|
|
hwHttpObjects OBJECT IDENTIFIER ::= { hwHttpMIB 1 }
|
|
hwHttpConformance OBJECT IDENTIFIER ::= { hwHttpMIB 2 }
|
|
|
|
-- ============================================================================
|
|
--
|
|
-- ======================= Objects definitions=================================
|
|
--
|
|
-- ============================================================================
|
|
hwHttpConfiguration OBJECT IDENTIFIER ::= { hwHttpObjects 1 }
|
|
|
|
hwHttpEnable OBJECT-TYPE
|
|
SYNTAX EnabledStatus
|
|
{
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates globally enable or disable the HTTP configuration. If the hwHttpEnable
|
|
is 1, HTTP server is enabled. If the hwHttpEnable is 2, HTTP server is
|
|
disabled. By default, HTTP server is enabled."
|
|
DEFVAL { 1 }
|
|
::= { hwHttpConfiguration 1 }
|
|
|
|
hwHttpPortNum OBJECT-TYPE
|
|
SYNTAX Integer32 (80|1025..55535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates globally port number the HTTP configuration. The value rangs from 1025 to 55535,
|
|
User can modify HTTP server listen in port number,
|
|
By default, HTTP server listen in 80 port."
|
|
DEFVAL { 80 }
|
|
::= { hwHttpConfiguration 2 }
|
|
|
|
hwHttpAclNum OBJECT-TYPE
|
|
SYNTAX Integer32 (0|2000..2999)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates globally ACL the HTTP configuration. The value rangs from 2000 to 2999,
|
|
user can modify HTTP server ACL number,By default, the ACL number is 0."
|
|
::= { hwHttpConfiguration 3 }
|
|
|
|
hwHttpTimeOut OBJECT-TYPE
|
|
SYNTAX Integer32 (1..35791)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates globally overtime the HTTP configuration. The value rangs from 1 to 35791,
|
|
User can modify HTTP server overtime interval,
|
|
By default, The time is 3 minutes."
|
|
DEFVAL { 3 }
|
|
::= { hwHttpConfiguration 4 }
|
|
|
|
hwHttpOnlineUserNum OBJECT-TYPE
|
|
SYNTAX Integer32 (0..5)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates the number of concurrent server users online."
|
|
::= { hwHttpConfiguration 5 }
|
|
|
|
hwHttpMaxUserNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates maximum number of concurrent server users allowed."
|
|
::= { hwHttpConfiguration 6 }
|
|
|
|
hwHttpUserInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwHttpUserInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HTTP user infomation configuration table."
|
|
::= { hwHttpConfiguration 7 }
|
|
|
|
hwHttpUserInfoEntry OBJECT-TYPE
|
|
SYNTAX HwHttpUserInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries of the HTTP user infomation configuration table."
|
|
INDEX{ hwHttpUserIndex }
|
|
::= { hwHttpUserInfoTable 1}
|
|
|
|
HwHttpUserInfoEntry ::=
|
|
SEQUENCE{
|
|
hwHttpUserIndex Integer32,
|
|
hwHttpUserName OCTET STRING,
|
|
hwHttpUserIpAddr IpAddress,
|
|
hwHttpUserLoginTime DateAndTime,
|
|
hwHttpUserTimeOut Integer32
|
|
}
|
|
|
|
hwHttpUserIndex OBJECT-TYPE
|
|
SYNTAX Integer32(1..5)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates the user index of user has logined HTTP server. The value rangs from 1 to 5."
|
|
::= {hwHttpUserInfoEntry 1}
|
|
|
|
hwHttpUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(1..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates the user name of user has logined HTTP server. It ranges from 1
|
|
to 64."
|
|
::= {hwHttpUserInfoEntry 2}
|
|
|
|
hwHttpUserIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates the source IP address of user has logined HTTP server."
|
|
::= {hwHttpUserInfoEntry 3}
|
|
|
|
hwHttpUserLoginTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates the date and time of user logined HTTP server."
|
|
::= {hwHttpUserInfoEntry 4}
|
|
|
|
hwHttpUserTimeOut OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object indicates the overtime of user logined HTTP server."
|
|
::= {hwHttpUserInfoEntry 5}
|
|
|
|
--
|
|
-- ***********************************************************
|
|
--
|
|
-- HAUWEIDLDPMIBCONFORMANCE
|
|
--
|
|
-- ***********************************************************
|
|
--
|
|
|
|
hwHttpCompliances OBJECT IDENTIFIER ::= { hwHttpConformance 1 }
|
|
hwHttpGroups OBJECT IDENTIFIER ::= { hwHttpConformance 2 }
|
|
-- compliance statements
|
|
hwHttpCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for SNMP entities which implement
|
|
the HUAWEI-HTTP-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
hwHttpConfigGroup,
|
|
hwHttpInfoGroup
|
|
}
|
|
::= { hwHttpCompliances 1 }
|
|
|
|
-- MIB groupings
|
|
hwHttpConfigGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hwHttpEnable,
|
|
hwHttpPortNum,
|
|
hwHttpAclNum,
|
|
hwHttpTimeOut
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which are used to configure the
|
|
HTTP implementation behavior.
|
|
This group is mandatory for agents which implement the HTTP."
|
|
::= { hwHttpGroups 1 }
|
|
|
|
hwHttpInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
hwHttpOnlineUserNum,
|
|
hwHttpMaxUserNum,
|
|
hwHttpUserName,
|
|
hwHttpUserIpAddr,
|
|
hwHttpUserLoginTime,
|
|
hwHttpUserTimeOut
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects indicates the information of HTTP server and users."
|
|
::= { hwHttpGroups 2 }
|
|
|
|
END
|
|
|
|
--
|
|