- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
537 lines
18 KiB
Text
537 lines
18 KiB
Text
HP-SYSTEM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Gauge32, IpAddress,
|
|
NOTIFICATION-TYPE, Unsigned32,
|
|
Integer32 FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, TruthValue,
|
|
DisplayString FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP,
|
|
NOTIFICATION-GROUP FROM SNMPv2-CONF
|
|
hpProcurveCommon FROM HP-BASE-MIB;
|
|
|
|
hpProcurveSystem MODULE-IDENTITY
|
|
LAST-UPDATED "200502011455Z"
|
|
ORGANIZATION "Hewlett Packard Company,
|
|
ProCurve Networking Business"
|
|
CONTACT-INFO "Hewlett Packard Company
|
|
8000 Foothills Blvd.
|
|
Roseville, CA 95747"
|
|
DESCRIPTION "This MIB module describes objects for basic
|
|
management of devices in the HP Procurve
|
|
product line."
|
|
REVISION "200502011455Z" -- February 1, 2005
|
|
DESCRIPTION "Modified to reflect new OID hierarchy for
|
|
HP J8162A XL Access Controller Module."
|
|
|
|
::= { hpProcurveCommon 1 }
|
|
|
|
hpProcurveSysMib OBJECT IDENTIFIER ::= { hpProcurveSystem 1 }
|
|
hpSystemMIBObjects OBJECT IDENTIFIER ::= { hpProcurveSystem 2 }
|
|
|
|
hpConfig OBJECT IDENTIFIER ::= { hpSystemMIBObjects 1 }
|
|
hpStatus OBJECT IDENTIFIER ::= { hpSystemMIBObjects 2 }
|
|
hpNotificationsConfig OBJECT IDENTIFIER ::= { hpSystemMIBObjects 3 }
|
|
|
|
|
|
-- System objects
|
|
hpProductDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Textual Description of the HW product"
|
|
::= { hpProcurveSysMib 1 }
|
|
|
|
hpProductHWVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "HW version of the product"
|
|
::= { hpProcurveSysMib 2 }
|
|
|
|
hpProductSWVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "SW version of the product"
|
|
::= { hpProcurveSysMib 3 }
|
|
|
|
hpProductSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Serial Number of the product"
|
|
::= { hpProcurveSysMib 4 }
|
|
|
|
|
|
hpProductLastChange OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Date and time of last configuration change"
|
|
::= { hpProcurveSysMib 5 }
|
|
|
|
-- Environmental
|
|
hpCpuTemperature OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current temperature in degrees centigrade
|
|
of the CPU."
|
|
::= { hpProcurveSysMib 6 }
|
|
|
|
hpPowerSupplyTemperature OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION "Current temperature in degrees centigrade
|
|
of the power supply."
|
|
::= { hpProcurveSysMib 7 }
|
|
|
|
hpChassisTemperature OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current temperature in degrees centigrade
|
|
of the mother board. Note: this is not the
|
|
ambient temperature of the box."
|
|
::= { hpProcurveSysMib 8 }
|
|
|
|
hpFanStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HpFanStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of operational status of all internal
|
|
cooling fans."
|
|
::= { hpProcurveSysMib 9 }
|
|
|
|
hpFanStatusEntry OBJECT-TYPE
|
|
SYNTAX HpFanStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry in table of all internal cooling fans."
|
|
INDEX { hpFanNumber }
|
|
::= { hpFanStatusTable 1 }
|
|
|
|
HpFanStatusEntry ::=
|
|
SEQUENCE {
|
|
hpFanNumber INTEGER,
|
|
hpFanOperational INTEGER,
|
|
hpFanSpeed Integer32
|
|
}
|
|
|
|
hpFanNumber OBJECT-TYPE
|
|
SYNTAX INTEGER { cpu(1),power(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identifier of cooling fan, numbered to represent what
|
|
hardware the fan is supposed to be cooling."
|
|
::= { hpFanStatusEntry 1 }
|
|
|
|
hpFanOperational OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1),false(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Operational status of a cooling fan."
|
|
::= { hpFanStatusEntry 2 }
|
|
|
|
hpFanSpeed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Speed of the fan in RPM."
|
|
::= { hpFanStatusEntry 3 }
|
|
|
|
-- hpConfig group
|
|
-- Additional information relating to the configuration of the HP ProCurve Networking
|
|
-- Business Device
|
|
|
|
|
|
hpName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing information about the
|
|
device. For instance, this string reflects the setting of
|
|
the HP J8162A XL Access Controller Module Name available on the Administrative
|
|
Web based User Interface. If no HP J8162A XL Access Controller Module name
|
|
is entered, this object contains a zero-length string."
|
|
::= { hpConfig 2 }
|
|
|
|
hpSystemID OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique identifier for this device, as used by
|
|
this system, or a master controlling system. For instance, an
|
|
HP J8162A XL Access Controller Module would report the systemID used by the
|
|
Access Control Server 740wl to uniquely identify this device."
|
|
::= { hpConfig 3 }
|
|
|
|
|
|
hpState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
up(2), -- ready to pass packets
|
|
down(3),
|
|
primary(4), -- for Failover operation
|
|
secondary(5) -- for Failover operation
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the device. A HP ProCurve Networking Business
|
|
device can be configured for standalone operation,
|
|
Failover (ie with a redundant peer), or for Distribution
|
|
of configuration from a controlling central system to
|
|
remote entities.
|
|
unknown(1) - system Configuration status unknown
|
|
up(2) - a standalone system is operational.
|
|
down(3) - a system is not operational.
|
|
primary(4) - system is running as the primary in
|
|
a Failover peer configuration.
|
|
secondary(5) - system is running as the backup in
|
|
a Failover peer configuration."
|
|
::= { hpConfig 4 }
|
|
|
|
hpDistributionType OBJECT-TYPE
|
|
-- NOT CURRENTLY SUPPORTED - will report dummy values
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
rightsPush(2) -- push central rights to remote systems.
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The most recent distribution event type on a device.
|
|
This object will change dynamically based on
|
|
the most recently triggered distribution event.
|
|
unknown(1) - the distribution event type
|
|
none(2) - no distribution event has occurred
|
|
rightsPush(3) - the central Access Control Server 740wl
|
|
has triggered a rights push event to remote Access Control Server
|
|
740wls."
|
|
::= { hpConfig 5 }
|
|
|
|
hpDistributionStatus OBJECT-TYPE
|
|
-- NOT CURRENTLY SUPPORTED - will report dummy values
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
succeeded(2),
|
|
failed(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The most recent distribution event on a device.
|
|
This object will change dynamically based on
|
|
the most recently triggered distribution event.
|
|
unknown(1) - the distribution event status unknown
|
|
succeeded(2) - no distribution event has succeeded
|
|
failed(3) - the distribution event failed for some reason."
|
|
::= { hpConfig 6 }
|
|
|
|
hpIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administratively assigned IP address associated with the
|
|
device. This can be assigned statically on the
|
|
device Console port, or configured via DHCP."
|
|
::= { hpConfig 7 }
|
|
|
|
hpPeerIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administratively assigned IP address associated with a
|
|
redundant peer device, configured to work with this device
|
|
for failover purposes. This can be assigned statically on the
|
|
device Console port, or configured via DHCP. If the device
|
|
does not support Failover configuration, or none has been
|
|
configured, this object will report 0.0.0.0"
|
|
::= { hpConfig 8 }
|
|
|
|
hpTechSupportEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the current setting for the technical
|
|
support access to the device. A value of true(1)
|
|
indicates the Technical Support Access has been enabled. A value
|
|
of false(2) indicates this access has been disabled. Note
|
|
this object should only report true(2) if HP ProCurve Networking
|
|
Business Technical Support staff have requested this access
|
|
to the HP J8162A XL Access Controller Module for troubleshooting purposes."
|
|
DEFVAL { false }
|
|
|
|
::= { hpConfig 9 }
|
|
|
|
hpFailedAdminIpAddress OBJECT-TYPE
|
|
-- NOT CURRENTLY SUPPORTED - will report dummy values
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address associated with the last failed
|
|
authentication to the Administrative UI. If no Administrator
|
|
had failed authentication, this object will report 0.0.0.0"
|
|
::= { hpConfig 10 }
|
|
|
|
-- hpStatus
|
|
|
|
hpNumAccessControllers OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of HP J8162A XL Access Controller Modules known to this system.
|
|
If this system is an HP J8162A XL Access Controller Module, this value will be 1.
|
|
Otherwise, this value will be the number of HP J8162A XL Access Controller Modules
|
|
this system is connected to (i.e. An Access Control Server 740wl
|
|
connects to multiple HP J8162A XL Access Controller Module's)."
|
|
::= { hpStatus 1 }
|
|
|
|
hpNumClients OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of active authenticated or unauthenticated
|
|
clients known to this system. If this device is an
|
|
HP J8162A XL Access Controller Module, then this object reports
|
|
the aggregated number of clients across all ports. If this device
|
|
is a Access Control Server 740wl, it reports all Clients aggregated
|
|
across all HP J8162A XL Access Controller Modules known to this system."
|
|
::= { hpStatus 2 }
|
|
|
|
|
|
-- hpNotificationsConfig group
|
|
-- Configure system level notifications
|
|
|
|
hpFailoverNotificationEnabled OBJECT-TYPE
|
|
-- NOT CURRENTLY SUPPORTED - will report dummy values
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls whether a hpFailover notification will
|
|
be sent in the event of a failover occurrence between a primary
|
|
and standby system. By default this object is set to false(2)
|
|
for all systems."
|
|
::= { hpNotificationsConfig 1 }
|
|
|
|
hpDistributionNotificationEnabled OBJECT-TYPE
|
|
-- NOT CURRENTLY SUPPORTED - will report dummy values
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls whether a hpDistribution notification will
|
|
be sent in the event of a distribution event between a central
|
|
and remote systems. By default this object is set to false(2)
|
|
for all systems."
|
|
DEFVAL { false }
|
|
::= { hpNotificationsConfig 2 }
|
|
|
|
|
|
hpAdminAuthFailureNotificationEnabled OBJECT-TYPE
|
|
-- NOT CURRENTLY SUPPORTED - will report dummy values
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls whether a hpAdminAuthFailure
|
|
notification will be sent in the event of a failed
|
|
authentication attempt at the administrator login."
|
|
DEFVAL { false }
|
|
::= { hpNotificationsConfig 3 }
|
|
|
|
|
|
-- Traps
|
|
hpSystemTraps OBJECT IDENTIFIER ::= { hpProcurveSystem 0 }
|
|
|
|
fanDown NOTIFICATION-TYPE
|
|
OBJECTS { hpFanNumber }
|
|
STATUS current
|
|
DESCRIPTION "A fanDown trap signifies that hpFanOperational has
|
|
detected an event where the fan is not operating."
|
|
::= { hpSystemTraps 1 }
|
|
|
|
fanUp NOTIFICATION-TYPE
|
|
OBJECTS { hpFanNumber }
|
|
STATUS current
|
|
DESCRIPTION "A fanUp trap signifies that hpFanOperational has
|
|
detected an event where the fan is now operating."
|
|
::= { hpSystemTraps 2 }
|
|
|
|
temperatureAlarm NOTIFICATION-TYPE
|
|
OBJECTS { hpCpuTemperature }
|
|
STATUS current
|
|
DESCRIPTION "A temperatureAlarm signifies that the SNMP
|
|
entity, acting in an agent role, has detected that the
|
|
hpCpuTemperature has a value that exceeds acceptable
|
|
tolerances (i.e. it is too hot or too cold)."
|
|
::= { hpSystemTraps 3 }
|
|
|
|
hpFailover NOTIFICATION-TYPE
|
|
OBJECTS { hpIpAddress}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hpFailover signifies that the SNMP
|
|
entity, acting in an agent role, has detected that the
|
|
standby system in a primary, redundant operation has
|
|
become the primary system. This notification will only
|
|
be sent by what was formerly the standby system."
|
|
::= { hpSystemTraps 4 }
|
|
|
|
hpDistributionEvent NOTIFICATION-TYPE
|
|
-- NOT CURRENTLY SUPPORTED
|
|
OBJECTS { hpDistributionType, hpDistributionStatus}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hpDistributionEvent signifies that the SNMP
|
|
entity, acting in an agent role, has detected that the
|
|
central entity in a distributed system has triggered a
|
|
distribution event of hpDistributionType."
|
|
::= { hpSystemTraps 5 }
|
|
|
|
|
|
hpAdminAuthFailure NOTIFICATION-TYPE
|
|
-- NOT CURRENTLY SUPPORTED
|
|
OBJECTS { hpFailedAdminIpAddress}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hpAdminAuthFailure signifies that the SNMP
|
|
entity, acting in an agent role, has detected that
|
|
someone at the address reported by hpAdminIpAddress
|
|
has failed to authenticate to the device via
|
|
the administrative interface."
|
|
|
|
::= { hpSystemTraps 6 }
|
|
|
|
|
|
-- conformance information
|
|
|
|
hpSystemMIBConformance OBJECT IDENTIFIER ::= { hpProcurveSystem 3 }
|
|
hpCompliances OBJECT IDENTIFIER ::= { hpSystemMIBConformance 1 }
|
|
hpGroups OBJECT IDENTIFIER ::= { hpSystemMIBConformance 2 }
|
|
|
|
|
|
hpSystemMIBCompliance1 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the HP-SYSTEM-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { hpSystemGroup, hpConfigGroup }
|
|
|
|
GROUP hpEnvGroup
|
|
DESCRIPTION
|
|
"The hpEnvGroup is optional for all entities."
|
|
|
|
GROUP hpStatusGroup
|
|
DESCRIPTION
|
|
"The hpStatusGroup is optional for all entities."
|
|
|
|
|
|
GROUP hpNotificationsConfigGroup
|
|
DESCRIPTION
|
|
"The hpNotificationsConfigGroup is optional for all entities."
|
|
|
|
GROUP hpNotificationsGroup
|
|
DESCRIPTION
|
|
"The hpNotificationsGroup is optional for all entities."
|
|
|
|
OBJECT hpName
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT hpIpAddress
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT hpTechSupportEnabled
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT hpFailoverNotificationEnabled
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT hpDistributionNotificationEnabled
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT hpAdminAuthFailureNotificationEnabled
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
::= { hpCompliances 1 }
|
|
|
|
-- units of conformance
|
|
|
|
hpSystemGroup OBJECT-GROUP
|
|
OBJECTS { hpProductDescription, hpProductHWVersion, hpProductSWVersion,
|
|
hpProductSerialNumber, hpProductLastChange }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing system information
|
|
applicable to all devices."
|
|
::= { hpGroups 1 }
|
|
|
|
hpEnvGroup OBJECT-GROUP
|
|
OBJECTS { hpCpuTemperature, hpPowerSupplyTemperature, hpChassisTemperature,
|
|
hpFanNumber, hpFanOperational, hpFanSpeed }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing environmental information
|
|
applicable to all devices."
|
|
::= { hpGroups 2 }
|
|
|
|
hpConfigGroup OBJECT-GROUP
|
|
OBJECTS { hpName, hpSystemID, hpState, hpIpAddress, hpPeerIpAddress,
|
|
hpTechSupportEnabled, hpDistributionType, hpDistributionStatus,
|
|
hpFailedAdminIpAddress }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing configuration information
|
|
applicable to all devices."
|
|
::= { hpGroups 3 }
|
|
|
|
|
|
hpStatusGroup OBJECT-GROUP
|
|
OBJECTS { hpNumAccessControllers, hpNumClients }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing statistics
|
|
applicable to all HP J8162A XL Access Controller Module like devices."
|
|
::= { hpGroups 4 }
|
|
|
|
hpNotificationsConfigGroup OBJECT-GROUP
|
|
OBJECTS { hpFailoverNotificationEnabled,
|
|
hpDistributionNotificationEnabled,
|
|
hpAdminAuthFailureNotificationEnabled }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing notification configuration
|
|
information applicable to all devices."
|
|
::= { hpGroups 5 }
|
|
|
|
hpNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { fanDown, fanUp, temperatureAlarm,
|
|
hpFailover, hpDistributionEvent, hpAdminAuthFailure }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"notifications for primary failover, and authorization failures,
|
|
applicable to all devices."
|
|
::= { hpGroups 6 }
|
|
|
|
|
|
|
|
END
|