- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
1597 lines
43 KiB
Text
1597 lines
43 KiB
Text
-- This MIB is designed to manage system properties for Endace appliances.
|
|
--
|
|
-- LEGAL NOTICE:
|
|
-- This source code:
|
|
--
|
|
-- a) is a proprietary trade secret of Endace Technology Limited or any of
|
|
-- its related or affiliated companies, a New Zealand company, and its
|
|
-- suppliers and licensors ('Endace'). You must keep it strictly
|
|
-- confidential, and you must not copy, modify, disclose or distribute any
|
|
-- part of it to anyone else, without the prior written authorisation of
|
|
-- Endace Limited;
|
|
--
|
|
-- b) may also be part of inventions that are protected by patents and
|
|
-- patent applications; and
|
|
--
|
|
-- c) is copyright (C) to Endace, 2007 to 2022. All rights reserved.
|
|
|
|
ENDACE-SYSTEM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
endace
|
|
FROM ENDACE-MIB
|
|
MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
Counter64, Gauge32, Integer32, IpAddress, MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DisplayString, TEXTUAL-CONVENTION, TruthValue
|
|
FROM SNMPv2-TC
|
|
;
|
|
|
|
shogunSystemMIB MODULE-IDENTITY
|
|
LAST-UPDATED "202205030008Z" -- May 03, 2022
|
|
ORGANIZATION
|
|
"Endace Technology"
|
|
CONTACT-INFO
|
|
"postal: Endace Technology
|
|
6th floor
|
|
KPMG Centre
|
|
85 Alexandra Street
|
|
Hamilton 3204
|
|
New Zealand
|
|
|
|
email: support@endace.com"
|
|
DESCRIPTION
|
|
"General system objects that are common to all Endace
|
|
products,
|
|
|
|
covering CPU usage, process manager, mounted volumes and CMC.
|
|
|
|
The availability of some objects is limited by configuration or
|
|
existent hardware, such as CMC configuration or RAID array."
|
|
REVISION "202205030007Z" -- May 03, 2022
|
|
DESCRIPTION
|
|
"Added FIPS OIDs."
|
|
REVISION "202102182025Z" -- February 18, 2021
|
|
DESCRIPTION
|
|
"Added systemModel and systemSerial."
|
|
REVISION "201704280351Z" -- April 28, 2017
|
|
DESCRIPTION
|
|
"Added systemServiceLevel OIDs."
|
|
REVISION "201505290110Z" -- May 29, 2015
|
|
DESCRIPTION
|
|
"New notifications for diskIONormal, memUtilizationNormal and
|
|
netUtilizationNormal."
|
|
REVISION "201406200210Z" -- June 20, 2014
|
|
DESCRIPTION
|
|
"Support for RAID encryption information."
|
|
REVISION "201311242103Z" -- November 24, 2013
|
|
DESCRIPTION
|
|
"Added notifications for cmcConnectionUp/Down"
|
|
REVISION "201307240640Z" -- July 24, 2013
|
|
DESCRIPTION
|
|
"Additional notifications for IPFIX/Netflow."
|
|
REVISION "201306300640Z" -- June 30, 2013
|
|
DESCRIPTION
|
|
"Additional cpuIndex for cpuUtilNormal trap."
|
|
REVISION "201301141928Z" -- January 14, 2013
|
|
DESCRIPTION
|
|
"New testTrap."
|
|
REVISION "201210050336Z" -- October 05, 2012
|
|
DESCRIPTION
|
|
"New table for data partition files, some octet strings are
|
|
DisplayStrings now"
|
|
REVISION "201208282143Z" -- August 28, 2012
|
|
DESCRIPTION
|
|
"New MO raidDrvDefect."
|
|
REVISION "201207152213Z" -- July 15, 2012
|
|
DESCRIPTION
|
|
"New objects and notification for raid health status."
|
|
REVISION "201110240000Z" -- October 24, 2011
|
|
DESCRIPTION
|
|
"New objects and notifications for SSD and BBU"
|
|
REVISION "201109120000Z" -- September 12, 2011
|
|
DESCRIPTION
|
|
"New MO and trap for system disk RAID controller."
|
|
REVISION "201103010000Z" -- March 01, 2011
|
|
DESCRIPTION
|
|
"New enumeration type for 'raidStatusCode'"
|
|
REVISION "200709220000Z" -- September 22, 2007
|
|
DESCRIPTION
|
|
"Changed the type of applConnected and applOk to TruthValue."
|
|
REVISION "200705230000Z" -- May 23, 2007
|
|
DESCRIPTION
|
|
"Added compliance components and conformance statements.
|
|
|
|
Added CMC trap to indicate normal CMC behaviour where there
|
|
was an error condition."
|
|
REVISION "200704240000Z" -- April 24, 2007
|
|
DESCRIPTION
|
|
"Added a table for listing file system partitions. This table
|
|
is required so that we can return a reference to the parition
|
|
with the diskSpaceLow trap."
|
|
REVISION "200704170000Z" -- April 17, 2007
|
|
DESCRIPTION
|
|
"Added extra traps for system events such as CPU usage and
|
|
paging activity to update the user that an error condition that
|
|
did exist, no longer exists.
|
|
|
|
The diskSpaceLow trap now includes information to determine
|
|
which volume the trap is referring to."
|
|
REVISION "200702190000Z" -- February 19, 2007
|
|
DESCRIPTION
|
|
"System Initial revision, Shogun 1.0"
|
|
::= { endace 1 }
|
|
|
|
-- Unsigned 64 bit integer
|
|
--
|
|
-- Unsigned64 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An
|
|
-- unsigned 64 bit integer. We use SYNTAX Counter64 for the enconding
|
|
-- rules."
|
|
-- SYNTAX Counter64
|
|
--
|
|
-- TEXTUAL-CONVENTIONs for this MIB module
|
|
|
|
RaidStatusCode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status code returned by the RAID controller"
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
initializing(1),
|
|
migrating(2),
|
|
rebuilding(3),
|
|
recovery(4),
|
|
degradedInit(5),
|
|
degradedRbld(6),
|
|
partiallyDegraded(7),
|
|
degraded(8),
|
|
inoperable(9),
|
|
unknown(10)
|
|
}
|
|
|
|
variables OBJECT IDENTIFIER ::= { shogunSystemMIB 1 }
|
|
|
|
-- VARIABLES
|
|
|
|
systemAppliance OBJECT IDENTIFIER ::= { variables 1 }
|
|
|
|
systemVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System software version string"
|
|
::= { systemAppliance 1 }
|
|
|
|
cpu OBJECT IDENTIFIER ::= { systemAppliance 2 }
|
|
|
|
cpuLoad1 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One-minute CPU load in hundredths"
|
|
::= { cpu 1 }
|
|
|
|
cpuLoad5 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Five-minute CPU load in hundredths"
|
|
::= { cpu 2 }
|
|
|
|
cpuLoad15 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fifteen-minute CPU load in hundredths"
|
|
::= { cpu 3 }
|
|
|
|
cpuUtil1 OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Percentage CPU utilization, aggregated across all CPUs,
|
|
rolling average over the past minute"
|
|
::= { cpu 4 }
|
|
|
|
cpuTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of CPUs"
|
|
::= { cpu 5 }
|
|
|
|
cpuEntry OBJECT-TYPE
|
|
SYNTAX CpuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for one CPU"
|
|
INDEX
|
|
{ cpuIndex }
|
|
::= { cpuTable 1 }
|
|
|
|
CpuEntry ::= SEQUENCE
|
|
{
|
|
cpuIndex Unsigned32,
|
|
idleTime TimeTicks,
|
|
systemTime TimeTicks,
|
|
userTime TimeTicks,
|
|
utilPct1Min Unsigned32
|
|
}
|
|
|
|
|
|
cpuIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of CPU, starting from 0"
|
|
::= { cpuEntry 1 }
|
|
|
|
idleTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time in milliseconds CPU has spent idle"
|
|
::= { cpuEntry 2 }
|
|
|
|
systemTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time in milliseconds CPU has spent busy with system tasks"
|
|
::= { cpuEntry 3 }
|
|
|
|
userTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time in milliseconds CPU has spent busy with user tasks"
|
|
::= { cpuEntry 4 }
|
|
|
|
utilPct1Min OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Percentage CPU utilization over the past minute"
|
|
::= { cpuEntry 5 }
|
|
|
|
procmgr OBJECT IDENTIFIER ::= { systemAppliance 3 }
|
|
|
|
procTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ProcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of processes managed or monitored by Process Manager"
|
|
::= { procmgr 1 }
|
|
|
|
procEntry OBJECT-TYPE
|
|
SYNTAX ProcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for one process"
|
|
INDEX
|
|
{ procIndex }
|
|
::= { procTable 1 }
|
|
|
|
ProcEntry ::= SEQUENCE
|
|
{
|
|
procIndex Unsigned32,
|
|
procName DisplayString,
|
|
procStatus DisplayString,
|
|
procNumFailures Unsigned32
|
|
}
|
|
|
|
|
|
procIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Synthetic numeric unique ID of process"
|
|
::= { procEntry 1 }
|
|
|
|
procName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique name of process"
|
|
::= { procEntry 2 }
|
|
|
|
procStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current state of process"
|
|
::= { procEntry 3 }
|
|
|
|
procNumFailures OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times process has crashed or exited unexpectedly"
|
|
::= { procEntry 4 }
|
|
|
|
mountmgr OBJECT IDENTIFIER ::= { systemAppliance 5 }
|
|
|
|
mountTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MountEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of all mounted partitions"
|
|
::= { mountmgr 1 }
|
|
|
|
mountEntry OBJECT-TYPE
|
|
SYNTAX MountEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for one mounted partition"
|
|
INDEX
|
|
{ mountIndex }
|
|
::= { mountTable 1 }
|
|
|
|
MountEntry ::= SEQUENCE
|
|
{
|
|
mountIndex Unsigned32,
|
|
mountBytesAvail Counter64,
|
|
mountBytesFree Counter64,
|
|
mountBytesPercentFree Unsigned32,
|
|
mountBytesTotal Counter64,
|
|
mountBytesUsed Counter64,
|
|
mountPoint DisplayString,
|
|
mountDeviceName DisplayString,
|
|
mountInodesFree Counter64,
|
|
mountInodesPercentFree Unsigned32,
|
|
mountInodesTotal Counter64,
|
|
mountInodesUsed Counter64
|
|
}
|
|
|
|
|
|
mountIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater then or equal to one, for each mount
|
|
in the managed system. It is recommended that values are
|
|
assigned contiguously starting from 1."
|
|
::= { mountEntry 1 }
|
|
|
|
mountBytesAvail OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of available bytes on the mount."
|
|
::= { mountEntry 2 }
|
|
|
|
mountBytesFree OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bytes free on the mount."
|
|
::= { mountEntry 3 }
|
|
|
|
mountBytesPercentFree OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bytes free as a percent of the total amount for
|
|
the mount."
|
|
::= { mountEntry 4 }
|
|
|
|
mountBytesTotal OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of bytes on the mount."
|
|
::= { mountEntry 5 }
|
|
|
|
mountBytesUsed OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bytes used on the mount."
|
|
::= { mountEntry 6 }
|
|
|
|
mountPoint OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The mount point for the device."
|
|
::= { mountEntry 7 }
|
|
|
|
mountDeviceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The device name of the mount."
|
|
::= { mountEntry 8 }
|
|
|
|
mountInodesFree OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inodes free on the mount."
|
|
::= { mountEntry 9 }
|
|
|
|
mountInodesPercentFree OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inodes free on the mount as a percentage of the
|
|
total."
|
|
::= { mountEntry 10 }
|
|
|
|
mountInodesTotal OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of inodes on the mount."
|
|
::= { mountEntry 11 }
|
|
|
|
mountInodesUsed OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of inodes used on the mount."
|
|
::= { mountEntry 12 }
|
|
|
|
sessions OBJECT IDENTIFIER ::= { systemAppliance 6 }
|
|
|
|
sessionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SessionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of active user-sessions"
|
|
::= { sessions 1 }
|
|
|
|
sessionEntry OBJECT-TYPE
|
|
SYNTAX SessionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for one active session"
|
|
INDEX
|
|
{ sessionId }
|
|
::= { sessionTable 1 }
|
|
|
|
SessionEntry ::= SEQUENCE
|
|
{
|
|
sessionId Unsigned32,
|
|
username DisplayString,
|
|
usernameLocal DisplayString,
|
|
remoteAddr IpAddress,
|
|
remoteHostname DisplayString,
|
|
clientDescr DisplayString
|
|
}
|
|
|
|
|
|
sessionId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Session ID"
|
|
::= { sessionEntry 1 }
|
|
|
|
username OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Username"
|
|
::= { sessionEntry 2 }
|
|
|
|
usernameLocal OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Local username"
|
|
::= { sessionEntry 3 }
|
|
|
|
remoteAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote IP address"
|
|
::= { sessionEntry 4 }
|
|
|
|
remoteHostname OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote hostname"
|
|
::= { sessionEntry 5 }
|
|
|
|
clientDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Client description"
|
|
::= { sessionEntry 6 }
|
|
|
|
raid OBJECT IDENTIFIER ::= { systemAppliance 7 }
|
|
|
|
raidDrvTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RaidDrvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table for RAID drives."
|
|
::= { raid 1 }
|
|
|
|
raidDrvEntry OBJECT-TYPE
|
|
SYNTAX RaidDrvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row of RAID drive table."
|
|
INDEX
|
|
{ raidDrvIndex }
|
|
::= { raidDrvTable 1 }
|
|
|
|
RaidDrvEntry ::= SEQUENCE
|
|
{
|
|
raidDrvIndex INTEGER,
|
|
raidDrvId INTEGER,
|
|
raidDrvType DisplayString,
|
|
raidDrvSerialNo DisplayString,
|
|
raidDrvWearout Integer32,
|
|
raidDrvLbaWritten Counter64,
|
|
raidDrvRealloc Integer32,
|
|
raidDrvPending Integer32,
|
|
raidDrvUncorrErrors Integer32,
|
|
raidDrvDefect Integer32,
|
|
raidDrvFdeCapable DisplayString,
|
|
raidDrvSecurity DisplayString,
|
|
raidDrvLocking DisplayString
|
|
}
|
|
|
|
|
|
raidDrvIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..64)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for RAID drive table"
|
|
::= { raidDrvEntry 1 }
|
|
|
|
raidDrvId OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Numerical drive ID as used in the device name."
|
|
::= { raidDrvEntry 2 }
|
|
|
|
raidDrvType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of drive (SATA, SAS, SSD, ect.)."
|
|
::= { raidDrvEntry 3 }
|
|
|
|
raidDrvSerialNo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial number of drive."
|
|
::= { raidDrvEntry 4 }
|
|
|
|
raidDrvWearout OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wear out level of SSD device."
|
|
::= { raidDrvEntry 5 }
|
|
|
|
raidDrvLbaWritten OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of logical blocks written to device."
|
|
::= { raidDrvEntry 6 }
|
|
|
|
raidDrvRealloc OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reallocated sectors."
|
|
::= { raidDrvEntry 7 }
|
|
|
|
raidDrvPending OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of currently pending sectors."
|
|
::= { raidDrvEntry 8 }
|
|
|
|
raidDrvUncorrErrors OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of uncorrectable errors."
|
|
::= { raidDrvEntry 9 }
|
|
|
|
raidDrvDefect OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of defect blocks."
|
|
::= { raidDrvEntry 10 }
|
|
|
|
raidDrvFdeCapable OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows, whether the drive supports Full Disc Encryption:
|
|
Capable: drive support Full Disk Encryption. Not Capable: drive
|
|
doesn't support Full Disk Encryption."
|
|
::= { raidDrvEntry 11 }
|
|
|
|
raidDrvSecurity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows security status of RAID drive:
|
|
Secured: drive is encrypted. Unsecured: drive is not
|
|
encrypted."
|
|
::= { raidDrvEntry 12 }
|
|
|
|
raidDrvLocking OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows locking status of RAID drive:
|
|
locked : keys don't match unlocked : keys match, disk is
|
|
accessible."
|
|
::= { raidDrvEntry 13 }
|
|
|
|
raidBbuTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RaidBbuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table for Battery Backup Units."
|
|
::= { raid 2 }
|
|
|
|
raidBbuEntry OBJECT-TYPE
|
|
SYNTAX RaidBbuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row of BBU table."
|
|
INDEX
|
|
{ raidBbuIndex }
|
|
::= { raidBbuTable 1 }
|
|
|
|
RaidBbuEntry ::= SEQUENCE
|
|
{
|
|
raidBbuIndex INTEGER,
|
|
raidBbuId INTEGER,
|
|
raidBbuStatus INTEGER,
|
|
raidBbuStatusInfo DisplayString
|
|
}
|
|
|
|
|
|
raidBbuIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for BBU table."
|
|
::= { raidBbuEntry 1 }
|
|
|
|
raidBbuId OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Numerical BBU ID."
|
|
::= { raidBbuEntry 2 }
|
|
|
|
raidBbuStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
ok(1),
|
|
warning(2),
|
|
error(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enumerated status of Battery Backup Unit."
|
|
::= { raidBbuEntry 3 }
|
|
|
|
raidBbuStatusInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String with status message."
|
|
::= { raidBbuEntry 4 }
|
|
|
|
dataPart OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of rotation files and VM images."
|
|
::= { systemAppliance 8 }
|
|
|
|
dataPartTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DataPartEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of files on /data partition to break down usage."
|
|
::= { dataPart 1 }
|
|
|
|
dataPartEntry OBJECT-TYPE
|
|
SYNTAX DataPartEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row of table of files on /data partition to break down
|
|
usage."
|
|
INDEX
|
|
{ dataPartIndex }
|
|
::= { dataPartTable 1 }
|
|
|
|
DataPartEntry ::= SEQUENCE
|
|
{
|
|
dataPartIndex INTEGER,
|
|
dataPartType INTEGER,
|
|
dataPartName DisplayString,
|
|
dataPartSize Gauge32,
|
|
dataPartSizeCap Gauge32,
|
|
dataPartMetadataSize Gauge32,
|
|
dataPartMetadataSizeCap Gauge32
|
|
}
|
|
|
|
|
|
dataPartIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for files table on /data."
|
|
::= { dataPartEntry 1 }
|
|
|
|
dataPartType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- Unknown file type
|
|
unknown(0),
|
|
-- RotationFile version 1
|
|
rotationFileV1(1),
|
|
-- RotationFile version 2
|
|
rotationFileV2(2),
|
|
-- Image file of virtual volume.
|
|
virtualVolume(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of file."
|
|
::= { dataPartEntry 2 }
|
|
|
|
dataPartName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Filename."
|
|
::= { dataPartEntry 3 }
|
|
|
|
dataPartSize OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "MB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Size of data files in MB."
|
|
::= { dataPartEntry 4 }
|
|
|
|
dataPartSizeCap OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "MB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum size of data files in MB."
|
|
::= { dataPartEntry 5 }
|
|
|
|
dataPartMetadataSize OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "MB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Size of disk area holding the meta data in MB."
|
|
::= { dataPartEntry 6 }
|
|
|
|
dataPartMetadataSizeCap OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "MB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum size of disk area holding the meta data in MB."
|
|
::= { dataPartEntry 7 }
|
|
|
|
systemServiceLevel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the current service level of the system:
|
|
|
|
nomal: regular operational state maintenance: system ios in
|
|
maintenance mode and supports only a minimum of functionality.
|
|
|
|
See User Guide for details."
|
|
::= { systemAppliance 9 }
|
|
|
|
systemSerial OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System Serial Number."
|
|
::= { systemAppliance 10 }
|
|
|
|
systemModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System Model."
|
|
::= { systemAppliance 11 }
|
|
|
|
cmc OBJECT IDENTIFIER ::= { variables 2 }
|
|
|
|
applTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ApplEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of appliances managed by the CMC"
|
|
::= { cmc 1 }
|
|
|
|
applEntry OBJECT-TYPE
|
|
SYNTAX ApplEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for one managed appliance"
|
|
INDEX
|
|
{ applIndex }
|
|
::= { applTable 1 }
|
|
|
|
ApplEntry ::= SEQUENCE
|
|
{
|
|
applIndex Unsigned32,
|
|
applName OCTET STRING,
|
|
applConnected TruthValue,
|
|
applOK TruthValue
|
|
}
|
|
|
|
|
|
applIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Synthetic numeric unique ID of appliance"
|
|
::= { applEntry 1 }
|
|
|
|
applName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..512))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual ID/name of appliance"
|
|
::= { applEntry 2 }
|
|
|
|
applConnected OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is CMC connected to this appliance (2=no, 1=yes)"
|
|
::= { applEntry 3 }
|
|
|
|
applOK OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Did this appliance pass its most recent status check (2=no,
|
|
1=yes)"
|
|
::= { applEntry 4 }
|
|
|
|
raidStatusCode OBJECT-TYPE
|
|
SYNTAX RaidStatusCode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Non-zero status code returned by the RAID controller when in
|
|
error."
|
|
::= { variables 3 }
|
|
|
|
sysDiskRaidStatusCode OBJECT-TYPE
|
|
SYNTAX RaidStatusCode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Non-zero status code returned by the system disk RAID
|
|
controller when in error."
|
|
::= { variables 4 }
|
|
|
|
raidDiskStatusCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
warning(1),
|
|
error(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Non-zero status code returned by the system when in error."
|
|
::= { variables 5 }
|
|
|
|
raidDiskSecurityMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- No RAID security
|
|
noSecurity(0),
|
|
-- RAID security enabled
|
|
securityEnabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RAID security status Information."
|
|
::= { variables 6 }
|
|
|
|
fips OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about FIPS"
|
|
::= { variables 7 }
|
|
|
|
fipsStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FIPS status:
|
|
disabled: FIPS mode is disabled, enabled: FIPS mode is enabled
|
|
and the power-on self-test passed, error: FIPS mode is enabled
|
|
but the power-on self-test failed."
|
|
::= { fips 1 }
|
|
|
|
systemTraps OBJECT IDENTIFIER ::= { shogunSystemMIB 3 }
|
|
|
|
-- NOTIFICATIONS
|
|
|
|
notificationPrefix OBJECT IDENTIFIER ::= { systemTraps 0 }
|
|
|
|
procCrash NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ procIndex, procName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A procCrash trap signifies that a process managed by Process
|
|
Manager has crashed and left a core file. The variable sent
|
|
with the notification indicates which process crashed."
|
|
::= { notificationPrefix 1 }
|
|
|
|
procExit NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ procIndex, procName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A procExit trap signifies that a process managed by Process
|
|
Manager has exited unexpectedly, but not left a core file. The
|
|
variable sent with the notification indicates which process
|
|
exited."
|
|
::= { notificationPrefix 2 }
|
|
|
|
procNormal NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ procIndex, procName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A procNormal trap signifies that a process managed by the
|
|
process manager (PM) was restarted by the PM because it failed
|
|
a liveness test or crashed unexpectedly and has now been
|
|
restarted. If the problem with the process is reoccurring then
|
|
either a procCrash, procExit or liveness test trap will be
|
|
resent."
|
|
::= { notificationPrefix 3 }
|
|
|
|
cpuUtilHigh NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ cpuIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average CPU utilization in the past minute has gone above
|
|
the acceptable threshold."
|
|
::= { notificationPrefix 4 }
|
|
|
|
cpuUtilNormal NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ cpuIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average CPU utilization in the past minute has gone below
|
|
the acceptable threshold again."
|
|
::= { notificationPrefix 5 }
|
|
|
|
pagingActivityHigh NOTIFICATION-TYPE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The system has been paging excessively (thrashing)"
|
|
::= { notificationPrefix 6 }
|
|
|
|
pagingActivityNormal NOTIFICATION-TYPE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The system was previously paging excessively (thrashing) but
|
|
is now paging within acceptable limits."
|
|
::= { notificationPrefix 7 }
|
|
|
|
smartError NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SMART has sent an event about a possible disk error"
|
|
::= { notificationPrefix 8 }
|
|
|
|
unexpectedShutdown NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system has shut down unexpectedly"
|
|
::= { notificationPrefix 9 }
|
|
|
|
diskSpaceLow NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ mountPoint }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Disk space on the system is low"
|
|
::= { notificationPrefix 10 }
|
|
|
|
diskSpaceNormal NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ mountPoint }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Disk space on the system was low but now has returned to a
|
|
normal operating level."
|
|
::= { notificationPrefix 11 }
|
|
|
|
procLivenessFailure NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ procIndex, procName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Process Manager has detected that a process has hung, and will
|
|
now perform its restart action"
|
|
::= { notificationPrefix 12 }
|
|
|
|
cmcStatusFailure NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ applName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more status criteria on a CMC-managed appliance have
|
|
failed"
|
|
::= { notificationPrefix 13 }
|
|
|
|
cmcStatusNormal NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ applName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A CMC-managed appliance had passes its status check, where it
|
|
previously failed."
|
|
::= { notificationPrefix 14 }
|
|
|
|
memUtilizationHigh NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Memory utilization on the system is high"
|
|
::= { notificationPrefix 15 }
|
|
|
|
netUtilizationHigh NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network utilization on the system is high"
|
|
::= { notificationPrefix 16 }
|
|
|
|
diskIOHigh NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Disk I/O on the system is high"
|
|
::= { notificationPrefix 17 }
|
|
|
|
cmcVersionMismatch NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ applName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system software version on a CMC managed appliance does
|
|
not match the server version"
|
|
::= { notificationPrefix 18 }
|
|
|
|
raidStatusOk NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RAID array is in its optimal state."
|
|
::= { notificationPrefix 19 }
|
|
|
|
raidStatusNotOk NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ raidStatusCode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RAID array is in a suboptimal state."
|
|
::= { notificationPrefix 20 }
|
|
|
|
userLogin NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ username, usernameLocal, remoteAddr, remoteHostname,
|
|
clientDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user has logged into the system"
|
|
::= { notificationPrefix 21 }
|
|
|
|
userLogout NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ username, usernameLocal, remoteAddr, remoteHostname,
|
|
clientDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user has logged out of the system"
|
|
::= { notificationPrefix 22 }
|
|
|
|
sysDiskRaidStatusOk NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system disk RAID array is in its optimal state."
|
|
::= { notificationPrefix 23 }
|
|
|
|
sysDiskRaidStatusNotOk NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ sysDiskRaidStatusCode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system disk RAID array is in a suboptimal state."
|
|
::= { notificationPrefix 24 }
|
|
|
|
raidDiskStatusOk NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Overall disk health is OK."
|
|
::= { notificationPrefix 25 }
|
|
|
|
raidDiskStatusNotOk NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ raidDiskStatusCode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Overall disk health is not OK.
|
|
(details in raidDiskStatusCode)"
|
|
::= { notificationPrefix 26 }
|
|
|
|
raidDrvWearWarning NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ raidDrvId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wearout level of SSD exceeded warning level."
|
|
::= { notificationPrefix 27 }
|
|
|
|
raidDrvWearCritical NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ raidDrvId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wearout level of SSD exceeded critical level."
|
|
::= { notificationPrefix 28 }
|
|
|
|
raidBbuOk NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ raidBbuId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Battery Backup Unit status is back to normal."
|
|
::= { notificationPrefix 29 }
|
|
|
|
raidBbuWarning NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ raidBbuId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Battery Backup Unit status went into warning state."
|
|
::= { notificationPrefix 30 }
|
|
|
|
raidBbuError NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ raidBbuId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Battery Backup Unit status went into alarm state."
|
|
::= { notificationPrefix 31 }
|
|
|
|
raidDiskWarning NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ raidDrvId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Disk health is in a warning state."
|
|
::= { notificationPrefix 32 }
|
|
|
|
raidDiskError NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ raidDrvId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Disk health is in an error state."
|
|
::= { notificationPrefix 33 }
|
|
|
|
cmcConnectionDown NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ applName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Connection to a CMC-managed appliance is down."
|
|
::= { notificationPrefix 34 }
|
|
|
|
cmcConnectionUp NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ applName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Connection to a CMC-managed appliance is up."
|
|
::= { notificationPrefix 35 }
|
|
|
|
ipfixEngineStart NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPFIX/Netflow generator engine was started."
|
|
::= { notificationPrefix 40 }
|
|
|
|
ipfixEngineStop NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPFIX/Netflow generator engine was stopped regularly. This
|
|
usually happens during reconfigurations."
|
|
::= { notificationPrefix 41 }
|
|
|
|
diskIONormal NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Disk I/O on system is back to normal"
|
|
::= { notificationPrefix 42 }
|
|
|
|
memUtilizationNormal NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Memory utilization on the system is back to normal"
|
|
::= { notificationPrefix 43 }
|
|
|
|
netUtilizationNormal NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network utilization on the system is back to normal"
|
|
::= { notificationPrefix 44 }
|
|
|
|
systemServiceLevelChanged NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ systemServiceLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is triggered when the system service level
|
|
changed."
|
|
::= { notificationPrefix 45 }
|
|
|
|
fipsStatusChanged NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{ fipsStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates a change of the FIPS status OID 'fipsStatus'."
|
|
::= { notificationPrefix 46 }
|
|
|
|
testTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test trap, can be triggered by CLI command 'snmp-server notify
|
|
send-test'."
|
|
::= { notificationPrefix 100 }
|
|
|
|
-- units of conformance
|
|
|
|
systemConformance OBJECT IDENTIFIER ::= { shogunSystemMIB 4 }
|
|
|
|
systemGroups OBJECT IDENTIFIER ::= { systemConformance 1 }
|
|
|
|
systemInformationGroup OBJECT-GROUP
|
|
OBJECTS
|
|
{ cpuIndex, cpuLoad1, cpuLoad5, cpuLoad15, cpuUtil1, idleTime,
|
|
mountBytesAvail, mountBytesFree, mountBytesPercentFree,
|
|
mountBytesTotal, mountBytesUsed, mountDeviceName, mountIndex,
|
|
mountPoint, procIndex, procName, procNumFailures, procStatus,
|
|
systemServiceLevel, systemTime, systemVersion, userTime,
|
|
utilPct1Min, systemModel, systemSerial }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information applicable to
|
|
the overall system."
|
|
::= { systemGroups 1 }
|
|
|
|
cmcInformationGroup OBJECT-GROUP
|
|
OBJECTS
|
|
{ applIndex, applName, applConnected, applOK }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information applicable to
|
|
CMC enabled appliances."
|
|
::= { systemGroups 2 }
|
|
|
|
systemNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS
|
|
{ cpuUtilHigh, cpuUtilNormal, diskIOHigh, diskIONormal,
|
|
diskSpaceLow, diskSpaceNormal, memUtilizationHigh,
|
|
memUtilizationNormal, netUtilizationHigh, netUtilizationNormal,
|
|
procCrash, procExit, procLivenessFailure, procNormal,
|
|
raidDiskError, raidDiskStatusNotOk, raidDiskStatusOk,
|
|
raidDiskWarning, raidStatusNotOk, raidStatusOk, smartError,
|
|
testTrap, unexpectedShutdown, userLogin, userLogout,
|
|
systemServiceLevelChanged }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing notifications related to
|
|
overall system health."
|
|
::= { systemGroups 3 }
|
|
|
|
cmcNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS
|
|
{ cmcConnectionDown, cmcConnectionUp, cmcStatusFailure,
|
|
cmcStatusNormal, cmcVersionMismatch }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information related to CMC
|
|
related notifications."
|
|
::= { systemGroups 4 }
|
|
|
|
systemInformationGroup2 OBJECT-GROUP
|
|
OBJECTS
|
|
{ clientDescr, mountInodesFree, mountInodesPercentFree,
|
|
mountInodesTotal, mountInodesUsed, remoteAddr, remoteHostname,
|
|
sessionId, username, usernameLocal }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing additional information
|
|
applicable to overall system."
|
|
::= { systemGroups 5 }
|
|
|
|
systemDiskRaidInformationGroup OBJECT-GROUP
|
|
OBJECTS
|
|
{ sysDiskRaidStatusCode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Managed objects associated to the system disk RAID array.
|
|
|
|
This group applies only to systems that use a RAID array as
|
|
system disk."
|
|
::= { systemGroups 6 }
|
|
|
|
systemDiskRaidNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS
|
|
{ sysDiskRaidStatusNotOk, sysDiskRaidStatusOk }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications associated to the system disk RAID array.
|
|
|
|
This group applies only to systems that use a RAID array as
|
|
system disk."
|
|
::= { systemGroups 7 }
|
|
|
|
ssdRaidInformationGroup OBJECT-GROUP
|
|
OBJECTS
|
|
{ raidDiskSecurityMode, raidDiskStatusCode, raidDrvDefect,
|
|
raidDrvFdeCapable, raidDrvId, raidDrvLbaWritten, raidDrvLocking,
|
|
raidDrvPending, raidDrvRealloc, raidDrvSecurity,
|
|
raidDrvSerialNo, raidDrvType, raidDrvUncorrErrors,
|
|
raidDrvWearout, raidStatusCode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This groups contains all objects being valid, when the sytem
|
|
deploys an SSD RAID array."
|
|
::= { systemGroups 8 }
|
|
|
|
ssdRaidNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS
|
|
{ raidDrvWearCritical, raidDrvWearWarning }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This groups contains all notifications being used, when the
|
|
sytem deploys an SSD RAID array."
|
|
::= { systemGroups 9 }
|
|
|
|
bbuInformationGroup OBJECT-GROUP
|
|
OBJECTS
|
|
{ raidBbuId, raidBbuStatus, raidBbuStatusInfo }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This groups contains all objects being valid, when the sytem
|
|
deploys Battery Backup Unit"
|
|
::= { systemGroups 10 }
|
|
|
|
bbuNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS
|
|
{ raidBbuError, raidBbuOk, raidBbuWarning }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This groups contains all notifications being used, when the
|
|
sytem deploys a Battery Backup Unit."
|
|
::= { systemGroups 11 }
|
|
|
|
dataPartGroup OBJECT-GROUP
|
|
OBJECTS
|
|
{ dataPartMetadataSize, dataPartMetadataSizeCap, dataPartName,
|
|
dataPartSize, dataPartSizeCap, dataPartType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All objects that describe files on the /data partition."
|
|
::= { systemGroups 12 }
|
|
|
|
ipfixNotifyGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS
|
|
{ ipfixEngineStart, ipfixEngineStop }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These notification will only emerge from a IPFIX/Netflow
|
|
generator appliance."
|
|
::= { systemGroups 13 }
|
|
|
|
obsoleteNotifications NOTIFICATION-GROUP
|
|
NOTIFICATIONS
|
|
{ pagingActivityHigh, pagingActivityNormal }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This group contains obsolete notifications, because even if
|
|
unused according to SMIv2 practices all notifications have to
|
|
be in at least one group."
|
|
::= { systemGroups 14 }
|
|
|
|
fipsInformationGroup OBJECT-GROUP
|
|
OBJECTS
|
|
{ fipsStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Conformance group for all FIPS related OIDs."
|
|
::= { systemGroups 15 }
|
|
|
|
fipsNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS
|
|
{ fipsStatusChanged }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group for all FIPS related notifications."
|
|
::= { systemGroups 16 }
|
|
|
|
systemCompliances OBJECT IDENTIFIER ::= { systemConformance 2 }
|
|
|
|
-- compliance statements
|
|
|
|
systemCompliance1 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for managed Endace network
|
|
entities."
|
|
|
|
MODULE ENDACE-SYSTEM-MIB
|
|
MANDATORY-GROUPS
|
|
{ systemInformationGroup, systemNotificationsGroup }
|
|
|
|
GROUP bbuNotificationsGroup
|
|
DESCRIPTION
|
|
"This group is valid if the system deploys a Battery Backup
|
|
Unit."
|
|
|
|
GROUP bbuInformationGroup
|
|
DESCRIPTION
|
|
"This group is valid if the system deploys a Battery Backup
|
|
Unit."
|
|
|
|
GROUP ssdRaidNotificationsGroup
|
|
DESCRIPTION
|
|
"This group is valid if the system deploys a SSD RAID
|
|
array."
|
|
|
|
GROUP ssdRaidInformationGroup
|
|
DESCRIPTION
|
|
"This group is valid if the system deploys a SSD RAID
|
|
array."
|
|
|
|
GROUP systemDiskRaidNotificationsGroup
|
|
DESCRIPTION
|
|
"This module is mandatory for the those appliances that use
|
|
an SSD RAID array as system disk."
|
|
|
|
GROUP cmcNotificationsGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for appliances that are CMC
|
|
enabled."
|
|
|
|
GROUP cmcInformationGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for appliances that are CMC
|
|
enabled."
|
|
|
|
GROUP systemDiskRaidInformationGroup
|
|
DESCRIPTION
|
|
"This module is mandatory for the those appliances that use
|
|
an SSD RAID array as system disk."
|
|
|
|
GROUP systemInformationGroup2
|
|
DESCRIPTION
|
|
"This module is mandatory for the those appliances that
|
|
support extra sytem information."
|
|
|
|
GROUP ipfixNotifyGroup
|
|
DESCRIPTION
|
|
"This group is only active on IPFIX/Netflow generator
|
|
appliances."
|
|
::= { systemCompliances 1 }
|
|
|
|
END
|