-- LEGAL NOTICE:
-- This source code:
--
-- a) is a proprietary trade secret of Endace Technology Limited or any of
-- its related or affiliated companies, a New Zealand company, and its
-- suppliers and licensors ('Endace'). You must keep it strictly
-- confidential, and you must not copy, modify, disclose or distribute any
-- part of it to anyone else, without the prior written
-- authorisation of Endace Limited;
--
-- b) may also be part of inventions that are protected by patents and
-- patent applications; and
--
-- c) is copyright (C) to Endace, 2009 to 2021. All rights reserved.
--
ENDACE-STREAM-MIB DEFINITIONS ::= BEGIN
IMPORTS
endace
FROM ENDACE-MIB
ModuleIndex
FROM ENDACE-MODULE-MIB
MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
FROM SNMPv2-CONF
Counter32, Counter64, Gauge32, Integer32, MODULE-IDENTITY,
NOTIFICATION-TYPE, OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
DisplayString, TEXTUAL-CONVENTION
FROM SNMPv2-TC
;
-- 1.3.6.1.4.1.18418.10
streamMIB MODULE-IDENTITY
LAST-UPDATED "202107210349Z" -- July 21, 2021
ORGANIZATION
"Endace"
CONTACT-INFO
"Postal: Endace Technology
6th floor
KPMG Centre
85 Alexandra Street
Hamilton 3204
New Zealand
Email: support@endace.com"
DESCRIPTION
"Support for managing DAG Stream interfaces."
REVISION "201908220147Z" -- August 22, 2019
DESCRIPTION
"Deprecated 'streamInMemBytes', can not hold 8GB of stream
buffer."
REVISION "201711012351Z" -- November 01, 2017
DESCRIPTION
"Declared several OIDs as obsolete: streamInAdminStatus,
streamInSnapLen, streamInPackets, streamInOctets,
streamInHCPackets, streamInHCOctets, streamInHCDropPackets."
REVISION "201310081934Z" -- October 08, 2013
DESCRIPTION
"Corrected OID for streamInDropThreshold."
REVISION "200905212346Z" -- May 21, 2009
DESCRIPTION
"Initial version."
::= { endace 10 }
StreamIndex ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A unique value, greater than or equal to zero for each stream
in the manages system. It is recommended that values are
assigned contiguously starting from 0."
SYNTAX Integer32
-- Notification Types
--
-- the following highly unusual OID is as it is for compatibility with RFC
-- 1315, the SNMP V1 specification.
--
-- 1.3.6.1.4.1.18418.10.0
streamEvents OBJECT IDENTIFIER ::= { streamMIB 0 }
-- 1.3.6.1.4.1.18418.10.0.1
streamInDropFault NOTIFICATION-TYPE
OBJECTS
{ streamInNum, streamInName }
STATUS current
DESCRIPTION
"A streamInDropFault notification signifies that the SNMP
entity, acting in an agent role, has detected that the
streamInDropPackets or streamInHCDropPackets has exceeded the
streamInDropThreshold value for an interval of one second.
Will contain information pertaining to identity of the dropping
stream."
::= { streamEvents 1 }
-- 1.3.6.1.4.1.18418.10.0.2
streamInDropNormal NOTIFICATION-TYPE
OBJECTS
{ streamInNum, streamInName }
STATUS current
DESCRIPTION
"A streamInDropNormal notification signifies that the SNMP
entity, acting in an agent role, has detected that the
streamInDropPackets or streamInHCDropPackets value is less than
the streamDropThreshold value for an interval of one second
after it was in streamInDropFault condition. Will contain
information pertaining to the identity of the dropping
stream."
::= { streamEvents 2 }
-- Scalars and Tables
--
-- 1.3.6.1.4.1.18418.10.1
streamObjects OBJECT IDENTIFIER ::= { streamMIB 1 }
streamDropTable OBJECT-TYPE
SYNTAX SEQUENCE OF StreamDropEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DAG module-level stream configuration details."
::= { streamObjects 1 }
streamDropEntry OBJECT-TYPE
SYNTAX StreamDropEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A single entry with stream attributes at the level of the DAG
module."
INDEX
{ streamDropModIndex }
::= { streamDropTable 1 }
StreamDropEntry ::= SEQUENCE
{
streamDropModIndex Unsigned32,
streamDropModule ModuleIndex,
streamDropEnabled INTEGER,
streamInDropThreshold Gauge32
}
streamDropModIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An integer value identifying a unique DAG Module on a system.
It is unique for all modules on the system."
::= { streamDropEntry 1 }
streamDropModule OBJECT-TYPE
SYNTAX ModuleIndex (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer value identifying a unique DAG Module on a system.
It is unique for all modules on the system. This value is the
same as the moduleIndex number assigned to the module."
::= { streamDropEntry 2 }
streamDropEnabled OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether dropping of packets occurs at the stream or
port level. If enabled (1) then dropping occurs at the
individual stream that has filled up, otherwise (2) dropping
will be occurring on a per port basis."
::= { streamDropEntry 3 }
streamInDropThreshold OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of dropped packets per second before which a
streamInDropFault will be raised. By default, this object will
have a value of 1000. If set to 0 it will disable the
generation of streamInDropFault notifications."
::= { streamDropEntry 4 }
streamInTable OBJECT-TYPE
SYNTAX SEQUENCE OF StreamInEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information about all In Stream
attributes."
::= { streamObjects 2 }
streamInEntry OBJECT-TYPE
SYNTAX StreamInEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in streamInTable. This entry contains attribute
details for a particular In Stream."
INDEX
{ streamInIndex }
::= { streamInTable 1 }
StreamInEntry ::= SEQUENCE
{
streamInIndex StreamIndex,
streamInNum StreamIndex,
streamInName DisplayString,
streamInModule ModuleIndex,
streamInLabel DisplayString,
streamInAdminStatus INTEGER,
streamInOperStatus INTEGER,
streamInMem Unsigned32,
streamInMemBytes Unsigned32,
streamInSnapLen Unsigned32,
streamInPackets Counter32,
streamInOctets Counter32,
streamInHCPackets Counter64,
streamInHCOctets Counter64,
streamInDropPackets Counter32,
streamInHCDropPackets Counter64
}
streamInIndex OBJECT-TYPE
SYNTAX StreamIndex (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An integer value identifying a unique stream on a system. It
is unique for all streams in the system."
::= { streamInEntry 1 }
streamInNum OBJECT-TYPE
SYNTAX StreamIndex (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer value identifying a unique stream on a system. It
is unique for all streams in the system. This value is the same
as that of streamInIndex."
::= { streamInEntry 2 }
streamInName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique string identifying a stream on a system. It is unique
for all streams on the system."
::= { streamInEntry 3 }
streamInModule OBJECT-TYPE
SYNTAX ModuleIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer value identifying the unique module on the system
to which this stream belongs. This value is the same as the
moduleIndex number assigned to the module."
::= { streamInEntry 4 }
streamInLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A string value that identifies the stream number relative to
a specific module. It is only unique within a specific module
and cannot be used to index the stream table."
::= { streamInEntry 5 }
streamInAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The desired operational stat of the stream. By default, all
streams are initialized to an admin status of up (1), meaning
they will receive packets. Subsequently the value of
streamInAdminStatus can be changed to down (2). If the
operational state is unknown then it will have a value of
unknown(3). There may be a momentary disconnect between the
desired state of the stream and its current operational state,
as the stream may take some time to move between states."
::= { streamInEntry 6 }
streamInOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational status of the stream. If the stream
can receive packets then it will be set to up (1), otherwise it
will be set to down (2). By default, a stream will have a value
of up (1). If the operational state is unknown, it will have a
value of unknown (3)."
::= { streamInEntry 7 }
streamInMem OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The memory allocated to the receive stream in mebibytes."
::= { streamInEntry 8 }
streamInMemBytes OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The memory allocated to the receive stream in bytes.
This OID is deprecated. It is accurate for EndaceProbes with
stream buffer up to 4GB. Use OID streamInMem instead, which
gives the stream buffer size in MiBytes."
::= { streamInEntry 9 }
streamInSnapLen OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Packets that are greater in length than the snaplen are
snapped to the size of streamInSnapLen. Otherwise the behavior
of snap length is determined by the value in moduleSnapLen."
::= { streamInEntry 10 }
streamInPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Count of the In packets received on the stream. This value
will be reinitialized by the management system."
::= { streamInEntry 11 }
streamInOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Count of the In octets that have been received on the stream
including framing characters. This value will be reinitialized
by the management system."
::= { streamInEntry 12 }
streamInHCPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The total number of packets received on the stream. This
object is the 64bit version of streamInPackets. This value will
be reinitialized by the management system."
::= { streamInEntry 13 }
streamInHCOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The total number of octets received on the stream including
framing characters. This object is a 64bit version of
streamInOctets. This value will be reinitialized by the
management system."
::= { streamInEntry 14 }
streamInDropPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of the In packets that have been dropped by the stream.
This value will be reinitialized by the management system, and
at other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { streamInEntry 15 }
streamInHCDropPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of the In packets that have been dropped by the stream.
This object is the 64bit version of streamInDropPackets. This
value will be reinitialized by the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { streamInEntry 16 }
streamOutTable OBJECT-TYPE
SYNTAX SEQUENCE OF StreamOutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information about all Out Stream
attributes."
::= { streamObjects 3 }
streamOutEntry OBJECT-TYPE
SYNTAX StreamOutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in streamOutTable. This entry contains attribute
details for a particular Out Stream."
INDEX
{ streamOutIndex }
::= { streamOutTable 1 }
StreamOutEntry ::= SEQUENCE
{
streamOutIndex StreamIndex,
streamOutNum StreamIndex,
streamOutName DisplayString,
streamOutModule ModuleIndex,
streamOutLabel DisplayString,
streamOutAdminStatus INTEGER,
streamOutOperStatus INTEGER,
streamOutMem Unsigned32,
streamOutMemBytes Unsigned32,
streamOutSnapLen Unsigned32,
streamOutPackets Counter32,
streamOutOctets Counter32,
streamOutHCPackets Counter64,
streamOutHCOctets Counter64
}
streamOutIndex OBJECT-TYPE
SYNTAX StreamIndex (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An integer value identifying a unique stream on a system. It
is unique for all streams in the system."
::= { streamOutEntry 1 }
streamOutNum OBJECT-TYPE
SYNTAX StreamIndex (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer value identifying a unique stream on a system. It
is unique for all streams in the system. This value is the same
as streamOutIndex."
::= { streamOutEntry 2 }
streamOutName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique string identifying a stream on a system. It is unique
for all streams on the system."
::= { streamOutEntry 3 }
streamOutModule OBJECT-TYPE
SYNTAX ModuleIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer value identifying the unique module on the system
to which this stream belongs. This value is the same as the
moduleIndex number assigned to the module."
::= { streamOutEntry 4 }
streamOutLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A string value that identifies the stream number relative to
a specific module. It is only unique within a specific module
and cannot be used to index the stream table."
::= { streamOutEntry 5 }
streamOutAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The desired operational stat of the stream. By default, all
streams are initialized to an admin status of up (1), meaning
they will receive packets. Subsequently the value of
streamInAdminStatus can be changed to down (2). If the
operational state is unknown then it will have a value of
unknown(3). There may be a momentary disconnect between the
desired state of the stream and its current operational state,
as the stream may take some time to move between states."
::= { streamOutEntry 6 }
streamOutOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational status of the stream. If the stream
can receive packets then it will be set to up (1), otherwise it
will be set to down (2). By default, a stream will have a value
of up (1). If the operational state is unknown, it will have a
value of unknown (3)."
::= { streamOutEntry 7 }
streamOutMem OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The memory allocated to the receive stream in mebibytes."
::= { streamOutEntry 8 }
streamOutMemBytes OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The memory allocated to the receive stream in bytes."
::= { streamOutEntry 9 }
streamOutSnapLen OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets that are greater in length than the snaplen are
snapped to the size of streamOutSnapLen. Otherwise the behavior
of snap length is determined by the value in moduleSnapLen."
::= { streamOutEntry 10 }
streamOutPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of the In packets transmitted on the stream. This value
will be reinitialized by the management system."
::= { streamOutEntry 11 }
streamOutOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of the In octets that have been transmitted on the
stream including framing characters. This value will be
reinitialized by the management system."
::= { streamOutEntry 12 }
streamOutHCPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets transmitted on the stream. This
object is the 64bit version of streamOutPackets. This value
will be reinitialized by the management system."
::= { streamOutEntry 13 }
streamOutHCOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets transmitted by the stream including
framing characters. This object is a 64bit version of
streamOutOctets. This value will be reinitialized by the
management system."
::= { streamOutEntry 14 }
-- Conformance
--
-- 1.3.6.1.4.1.18418.10.2
streamConf OBJECT IDENTIFIER ::= { streamMIB 2 }
-- Groups
--
-- 1.3.6.1.4.1.18418.10.2.1
streamGroups OBJECT IDENTIFIER ::= { streamConf 1 }
-- 1.3.6.1.4.1.18418.10.2.1.1
streamModuleAttributes OBJECT-GROUP
OBJECTS
{ streamDropModule, streamDropEnabled, streamInDropThreshold }
STATUS current
DESCRIPTION
"Group containing stream configuration details for DAG
module-level attributes."
::= { streamGroups 1 }
-- 1.3.6.1.4.1.18418.10.2.1.2
streamInDetail OBJECT-GROUP
OBJECTS
{ streamInNum, streamInName, streamInModule, streamInLabel }
STATUS current
DESCRIPTION
"In stream identification attributes. This group contains
everything needed to identify a unique string and its' DAG
Module."
::= { streamGroups 2 }
-- 1.3.6.1.4.1.18418.10.2.1.3
streamInAttributes OBJECT-GROUP
OBJECTS
{ streamInAdminStatus, streamInOperStatus, streamInMem,
streamInMemBytes, streamInSnapLen }
STATUS current
DESCRIPTION
"This group contains all In stream attributes."
::= { streamGroups 3 }
-- 1.3.6.1.4.1.18418.10.2.1.4
streamInCounters OBJECT-GROUP
OBJECTS
{ streamInPackets, streamInOctets, streamInHCPackets,
streamInHCOctets, streamInDropPackets, streamInHCDropPackets }
STATUS current
DESCRIPTION
"This group contains all In stream packet counters, both 32bit
and 64bit. Note that the 64bit counters are only supported on
high-speed cards."
::= { streamGroups 4 }
-- 1.3.6.1.4.1.18418.10.2.1.5
streamOutDetails OBJECT-GROUP
OBJECTS
{ streamOutNum, streamOutLabel, streamOutModule, streamOutName
}
STATUS current
DESCRIPTION
"Out stream identification attributes. This group contains
everything needed to identify a unique string and its' DAG
Module."
::= { streamGroups 5 }
-- 1.3.6.1.4.1.18418.10.2.1.6
streamOutAttributes OBJECT-GROUP
OBJECTS
{ streamOutAdminStatus, streamOutOperStatus, streamOutMem,
streamOutMemBytes, streamOutSnapLen }
STATUS current
DESCRIPTION
"This group contains all Out stream attributes."
::= { streamGroups 6 }
-- 1.3.6.1.4.1.18418.10.2.1.7
streamOutCounters OBJECT-GROUP
OBJECTS
{ streamOutPackets, streamOutOctets, streamOutHCPackets,
streamOutHCOctets }
STATUS current
DESCRIPTION
"This group contains all Out stream packet counters, both 32bit
and 64bit. Note that the 64bit counters are only supported on
high-speed cards."
::= { streamGroups 7 }
-- 1.3.6.1.4.1.18418.10.2.1.8
streamInEvents NOTIFICATION-GROUP
NOTIFICATIONS
{ streamInDropFault, streamInDropNormal }
STATUS current
DESCRIPTION
"This group contains notifications about In streams."
::= { streamGroups 8 }
-- Compliance
--
-- 1.3.6.1.4.1.18418.10.2.2
streamCompls OBJECT IDENTIFIER ::= { streamConf 2 }
-- Empty MODULE field indicates compliance to the containing MIB module
--
-- 1.3.6.1.4.1.18418.10.2.2.1
streamCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for ENDACE-STREAM entities which
implement the ENDACE-STREAM MIB."
MODULE ENDACE-STREAM-MIB
MANDATORY-GROUPS
{ streamModuleAttributes, streamInDetail, streamOutDetails,
streamInEvents }
::= { streamCompls 1 }
END