-- This MIB is designed to manage DAG modules in a Endace appliance. It
-- provides a number of generic interface types supporting Endace SONET and
-- Ethernet PHYs.
--
--
-- LEGAL NOTICE:
-- This source code:
--
-- a) is a proprietary trade secret of Endace Technology Limited or any of
-- its related or affiliated companies, a New Zealand company, and its
-- suppliers and licensors ('Endace'). You must keep it strictly
-- confidential, and you must not copy, modify, disclose or distribute any
-- part of it to anyone else, without the prior written
-- authorisation of Endace Limited;
--
-- b) may also be part of inventions that are protected by patents and
-- patent applications; and
--
-- c) is copyright (C) to Endace, 2007 to 2021. All rights reserved.
--
ENDACE-MODULE-MIB DEFINITIONS ::= BEGIN
IMPORTS
endace
FROM ENDACE-MIB
EndaceModuleType
FROM ENDACEModuleType-MIB
MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
FROM SNMPv2-CONF
Counter32, Counter64, Gauge32, Integer32, MODULE-IDENTITY,
NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks,
Unsigned32
FROM SNMPv2-SMI
DisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue
FROM SNMPv2-TC
;
shogunModuleMIB MODULE-IDENTITY
LAST-UPDATED "202107210349Z" -- July 21, 2021
ORGANIZATION
"Endace Technology"
CONTACT-INFO
"postal: Endace Technology
6th floor
KPMG Centre
85 Alexandra Street
Hamilton 3204
New Zealand
email: support@endace.com"
DESCRIPTION
"This MIB handles information about DAG Modules in Endace
appliances, formerly known as 'Shogun'."
REVISION "201905010037Z" -- May 01, 2019
DESCRIPTION
"Marked Timestamp Conversion notifications as obsolete since
they are not supported in OSm7.0.0 anymore"
REVISION "201402200111Z" -- February 20, 2014
DESCRIPTION
"New timestamp converter MOs, deprecated highSpeed MO."
REVISION "201310070408Z" -- October 07, 2013
DESCRIPTION
"Deprecated 'moduleVoltage', 'modifLastChange' and
'modifLinkDropThreshold'."
REVISION "201301220053Z" -- January 22, 2013
DESCRIPTION
"New modifUserLabel and extended modif traps."
REVISION "201209242131Z" -- September 24, 2012
DESCRIPTION
"New interface types for 10GBASE-L and 10GBASE-W, some OCTET
strings are DisplayStrings now."
REVISION "200910050000Z" -- October 05, 2009
DESCRIPTION
"Modified the field type of the moduleTemperature,
moduleVoltage entries in the moduleTable from Integer32 to
Unsigned32."
REVISION "200908050000Z" -- August 05, 2009
DESCRIPTION
"Fixed standards compliance issues, notifications currently do
not conform to the SMIv1 standard. Added additional conformance
statements and groups for all declared objects."
REVISION "200705230000Z" -- May 23, 2007
DESCRIPTION
"Added additional SONET level statistics and 64bit FCS counter
to ethHCStatsTable. This is primarily to support Endace 40Gb/s
product line.
Adjusted module compliance to better reflect DAG hardware.
Reduced the compliance requirements for some interfaces.
Added a modifLastChange attribute to record the value of
sysUpTime when the interface last changed operational state."
REVISION "200704230000Z" -- April 23, 2007
DESCRIPTION
"Final module and Interface attributes, including but not
limited to adding a name attribute so that a module and
interface could be identified by a unique string from both the
CLI and the MIB.
Distinguished between user firmware, factory firm- ware and
active firmware. We restrict the firmware that is loaded to
only active firmware."
REVISION "200704090000Z" -- April 09, 2007
DESCRIPTION
"Removed redundant attributes for modules, these are no longer
exported by the system."
REVISION "200703290000Z" -- March 29, 2007
DESCRIPTION
"Added additional attributes to the Ethernet and port
interfaces. Added additional traps to indicate specialized
error conditions on the interface and operational status of a
DAG module."
REVISION "200701270000Z" -- January 27, 2007
DESCRIPTION
"Initial version provides support for managing Endace
appliances equipped with standard Endace DAG cards, referred
to as 'modules'."
::= { endace 2 }
EndaceifType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used as the type qualifier for each row in
the interface table. It provides a connection between the
interface type and interface specific table."
SYNTAX INTEGER {
-- generic Ethernet interface, good for most Endace Ethernet PHYs
ethernet(1),
-- generic SONET interface, good for most Endace SONET PHYs.
sonet(2),
-- generic PDH interface, good for most Endace PDH PHYs.
pdh(3),
-- 10 Gigabit Ethernet (10GBASE-L)
ethernetLan(4),
-- 10 Gigabit Ethernet with Sonet/SDH compatible encoding
-- (10GBASE-W)
ethernetWan(5)
}
InterfaceIndex ::= TEXTUAL-CONVENTION
DISPLAY-HINT "x"
STATUS current
DESCRIPTION
"A unique value, greater then or equal to zero, for each
interface in the managed system. It is recommended that values
are assigned contiguously starting from 0."
SYNTAX Unsigned32
ModuleIndex ::= TEXTUAL-CONVENTION
DISPLAY-HINT "x"
STATUS current
DESCRIPTION
"A unique value, greater then zero, for each module in the
managed system. It is recommended that values are assigned
according to chases slot number starting from 1. Numbering
starting from 1 is due to legacy restrictions."
SYNTAX Unsigned32
moduleMIBObjects OBJECT IDENTIFIER ::= { shogunModuleMIB 1 }
moduleTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModuleTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The modules that are accessible for the system. There will be
one row in this table for each DAG module in the system."
::= { moduleMIBObjects 1 }
moduleTableEntry OBJECT-TYPE
SYNTAX ModuleTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Settings for a particular module on the system."
INDEX
{ moduleIndex }
::= { moduleTable 1 }
ModuleTableEntry ::= SEQUENCE
{
moduleIndex ModuleIndex,
moduleName DisplayString,
moduleType EndaceModuleType,
moduleActiveFirmware DisplayString,
moduleOperStatus INTEGER,
moduleLastChange TimeTicks,
moduleSnapLen Unsigned32,
moduleTemperature Unsigned32,
moduleVoltage Unsigned32
}
moduleIndex OBJECT-TYPE
SYNTAX ModuleIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater then zero, for each DAG module. It is
recommended that values are assigned contiguously starting from
1. The value for each DAG module must remain constant at least
from one re-initialization of the entity's network management
system to the next re-initialization. The moduleIndex
corresponds to its slot number within the system chassis."
::= { moduleTableEntry 1 }
moduleName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique string that identifies the module within the
system."
::= { moduleTableEntry 2 }
moduleType OBJECT-TYPE
SYNTAX EndaceModuleType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The moduleType field allows us to store module specific
information for a module in a separate table indexed by
moduleIndex. Types are assigned by Endace, and updated through
the use of the EndaceModuleType textual convention."
::= { moduleTableEntry 3 }
moduleActiveFirmware OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique string identifying the current active firmware on the
module."
::= { moduleTableEntry 4 }
moduleOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
-- in some unknown mode
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state of the module. moduleOperStatus may
have the value up(1), down(2) or unknown(3). There is currently
no support for the values 'dormant', 'notPresent',
'lowerLayerDown' or 'testing'."
::= { moduleTableEntry 5 }
moduleLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the module entered its
current operational state. If the current state was entered
prior to the last re-initialization of the local network
management subsystem, then this object contains a zero
value."
::= { moduleTableEntry 6 }
moduleSnapLen OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Packets that are greater in length then the snaplen are
snapped to the size of moduleSnapLen. Otherwise the behavior of
snap length is determined by the value of the moduleVarLen
attribute."
::= { moduleTableEntry 7 }
moduleTemperature OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current temperature of the module."
::= { moduleTableEntry 8 }
moduleVoltage OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Current voltage of the module."
::= { moduleTableEntry 9 }
moduleInterfaces OBJECT IDENTIFIER ::= { moduleMIBObjects 2 }
-- Access to interfaces through the port table.
modifTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModifEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Generic configuration for a collection of interfaces attached
to a particular system. There will be one row in this table for
each module interface in the system."
::= { moduleInterfaces 1 }
modifEntry OBJECT-TYPE
SYNTAX ModifEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Generic configuration for a particular module interface in the
system."
INDEX
{ modifModIndex }
::= { modifTable 1 }
ModifEntry ::= SEQUENCE
{
modifModIndex InterfaceIndex,
modifPortLabel DisplayString,
modifModule Integer32,
modifName DisplayString,
modifType EndaceifType,
modifMtu Integer32,
modifInAdminStatus INTEGER,
modifInOperStatus INTEGER,
modifLastChange TimeTicks,
modifLinkUpDownTrapEnable INTEGER,
modifLinkDropThreshold Gauge32,
modifSpeed Gauge32,
modifHighSpeed Gauge32,
modifInOctets Counter32,
modifInPackets Counter32,
modifInDropPackets Counter32,
modifOutOctets Counter32,
modifOutPackets Counter32,
modifHCInOctets Counter64,
modifHCInPackets Counter64,
modifHCInDropPackets Counter64,
modifHCOutOctets Counter64,
modifHCOutPackets Counter64,
modifCounterDiscontinuityTime TimeTicks,
modifHCInErrors Counter64,
modifUserLabel DisplayString,
modifPhysAddr PhysAddress
}
modifModIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer value identifying a unique interface on a system,
if on a module. It is unique for all interfaces on the
system."
::= { modifEntry 1 }
modifPortLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A character value that identifies the physical interface
number relative to a specific module. It is only unique within
a specific module and cannot be used to index the interface
table."
::= { modifEntry 2 }
modifModule OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer value identifying the unique module on the system,
to which this interface belongs. This value is the same as the
moduleIndex number assigned to the module."
::= { modifEntry 3 }
modifName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique string that identifies the module within the
system."
::= { modifEntry 4 }
modifType OBJECT-TYPE
SYNTAX EndaceifType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique string specifying a if specific table for port
specific attributes."
::= { modifEntry 5 }
modifMtu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The size of the largest packet which can be sent/received on
the interface, specified in octets."
::= { modifEntry 6 }
modifInAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
-- read to receive packets
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The desired operational state of the interface. By default all
interfaces are initialized to an admin status of up(1), meaning
they will receive packets. Subsequently the value of the
modifInAdminStatus can be changed to the down(2) state. If the
operational state is unknown then it will have a value of
unknown(3). There may be some momentary disconnect between the
desired state of the interface and its current operational
state, as the interface may take some time to move between
states."
::= { modifEntry 7 }
modifInOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the current operational state of the interface. If the
interface can receive packets then it will be set to up(1),
otherwise it will be set to down(2). By default, this object
will have the value of up(1). If the operational state is
unknown then it will have a value of unknown(3)."
::= { modifEntry 8 }
modifLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The value of sysUpTime at the time the interface entered its
current operational state. If the current state was entered
prior to the last re-initialization of the local management
subsystem, then this object contains a 0 value."
::= { modifEntry 9 }
modifLinkUpDownTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether modlinkUp/modlinkDown traps should be
generated for this interface. By default, this object will have
the value of enabled(1)."
::= { modifEntry 10 }
modifLinkDropThreshold OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The number of dropped packets per second before which a
dropFault will be raised. By default, this object will have the
value of 1000. If set to 0, it will disable the generation of
dropFault notifications."
::= { modifEntry 11 }
modifSpeed OBJECT-TYPE
SYNTAX Gauge32
UNITS "Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the interfaces current bandwidth in million
bits per second (Mbits/s)."
::= { modifEntry 12 }
modifHighSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The use of this MO is deprecated."
::= { modifEntry 13 }
modifInOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Count of the In Octets that have been received on the
interface including framing characters. This value will be
reinitialized by the management system, and at other times as
indicated by the value of the modifCounterDiscontinuityTime."
::= { modifEntry 14 }
modifInPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Count of the In packets that have been received on the
interface. This value will be reinitialized by the management
system, and at other times as indicated by the value of the
modifCounterDiscontinuityTime."
::= { modifEntry 15 }
-- This value is not supported on DAG 9.2x cards and may be empty.
modifInDropPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Count of the In packets that have been dropped at the PHY
interface. This value will be reinitialized by the management
system, and at other times as indicated by the value of the
modifCounterDiscontinuityTime."
::= { modifEntry 16 }
modifOutOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Count of the Out Octets that have been transmitted on the
interface. This value will be reinitialized by the management
system, and at other times as indicated by the value of the
modifCounterDiscontinuityTime."
::= { modifEntry 17 }
modifOutPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Count of the Out packets that have been transmitted on the
interface. This value will be reinitialized by the management
system, and at other times as indicated by the value of the
modifCounterDiscontinuityTime."
::= { modifEntry 18 }
modifHCInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets received on the interface including
framing characters. This object is a 64bit version of
modifInOctets. This value will be reinitialized by the
management system, and at other times as indicated by the
value of modifCounterDiscontinuityTime."
::= { modifEntry 19 }
modifHCInPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received on the interface. This
object is a 64bit version of modifInPackets. This value will be
reinitialized by the management system, and at other times as
indicated by the value of modifCounterDiscontinuityTime."
::= { modifEntry 20 }
-- This value is not supported on DAG9.2x cards and may be empty.
modifHCInDropPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that have been dropped at the PHY
interface. This object is a 64bit version of the
modifInDropPackets. This value will be reinitialized by the
management system, and at other times as indicated by the value
of the modifCounterDiscontinuityTime."
::= { modifEntry 21 }
modifHCOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets sent on the interface. This object
is a 64bit version of modifOutOctets. This value will be
reinitialized by the management system, and at other times as
indicated by the value of modifCounterDiscontinuityTime."
::= { modifEntry 22 }
modifHCOutPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets sent on the interface. This object
is a 64bit version of modifOutPackets. This value will be
reinitialized by the management system, and at other times as
indicated by the value of modifCounterDiscontinuityTime."
::= { modifEntry 23 }
modifCounterDiscontinuityTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime on the most recent occasion at which
any one or more of this interface's counters suffered a
discontinuity. The relevant counters are the specific instances
associated with this interface of any Counter32 or Counter64
object contained in the modifTable. This value is 0 if no such
discontinuities have occurred since the last re-initialization
of the local management subsystem."
::= { modifEntry 24 }
modifHCInErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of receive errors on this PHY interface."
::= { modifEntry 25 }
modifUserLabel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"User definable label for DAG ports."
::= { modifEntry 26 }
modifPhysAddr OBJECT-TYPE
SYNTAX PhysAddress (SIZE(0..18))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical address of the interface (MAC address)."
::= { modifEntry 27 }
modoptTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModoptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with information about all DAG SFP Modules."
::= { moduleInterfaces 3 }
modoptEntry OBJECT-TYPE
SYNTAX ModoptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row of table with information about all DAG SFP Modules."
INDEX
{ modoptIndex }
::= { modoptTable 1 }
ModoptEntry ::= SEQUENCE
{
modoptIndex Unsigned32,
modoptName DisplayString,
modoptDetect TruthValue,
modoptLOS TruthValue,
modoptRxPower DisplayString,
modoptRxPowerOk TruthValue,
modoptTxPower DisplayString,
modoptTxPowerOk TruthValue,
modoptTemp DisplayString,
modoptTempOk TruthValue,
modoptVolt DisplayString,
modoptVoltOk TruthValue,
modoptCompliance DisplayString
}
modoptIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique, immutable index of optical modules in DAG cards."
::= { modoptEntry 1 }
modoptName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of DAG port were the SFP module is plugged in."
::= { modoptEntry 2 }
modoptDetect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical indicator where a module was detected or not."
::= { modoptEntry 3 }
modoptLOS OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical 'Loss of Signal' indicator.
'true': no signal 'false': signal detected."
::= { modoptEntry 4 }
modoptRxPower OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received optical power in [dbm]."
::= { modoptEntry 5 }
modoptRxPowerOk OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical indicator that the measured RX power is within the
allowed range.
The thresholds can be defined via CLI commands."
::= { modoptEntry 6 }
modoptTxPower OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted optical power in [dbm]."
::= { modoptEntry 7 }
modoptTxPowerOk OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical indicator that the measured TX power is within the
allowed range.
The thresholds can be defined via CLI commands."
::= { modoptEntry 8 }
modoptTemp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature inside the SFP module in [degrees Celsius]."
::= { modoptEntry 9 }
modoptTempOk OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical indicator that the measured temperature is within the
allowed range.
The thresholds can be defined via CLI commands."
::= { modoptEntry 10 }
modoptVolt OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Voltage applied to SFP module in [V]."
::= { modoptEntry 11 }
modoptVoltOk OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical indicator that the applied voltage is within the
allowed range.
The thresholds can be defined via CLI commands."
::= { modoptEntry 12 }
modoptCompliance OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"List of compliances issued plugged-in SFP module."
::= { modoptEntry 13 }
moduleTraps1 OBJECT IDENTIFIER ::= { moduleMIBObjects 3 }
-- Module Traps
modlinkUp NOTIFICATION-TYPE
OBJECTS
{ modifModIndex, modifName, modifUserLabel, moduleIndex }
STATUS current
DESCRIPTION
"A linkup trap signifies that the SNMP entity, acting in an
agent role has detected that the modifInOperStatus object for
one of its communication links left the down state and
transitioned to the up state."
::= { moduleTraps1 1 }
modlinkDown NOTIFICATION-TYPE
OBJECTS
{ modifModIndex, modifName, modifUserLabel, moduleIndex }
STATUS current
DESCRIPTION
"A linkdown trap signifies that the SNMP entity, acting in an
agent role, has detected that the modifInOperStatus object for
one of its communication links left the up state and
transitioned to the down state."
::= { moduleTraps1 2 }
dropFault NOTIFICATION-TYPE
OBJECTS
{ modifModIndex, modifName, modifUserLabel, moduleIndex }
STATUS current
DESCRIPTION
"A dropFault trap signifies that the SNMP entity, acting in an
agent role, has detected that the ifInDropCount or
ifHCInDropCount has exceeded the modifLinkDropThreshold value
for an interval of 1 second."
::= { moduleTraps1 5 }
dropNormal NOTIFICATION-TYPE
OBJECTS
{ modifModIndex, modifName, modifUserLabel, moduleIndex }
STATUS current
DESCRIPTION
"A dropNormal trap signifies that the SNMP entity, acting in an
agent role, has detected that the ifInDropCount or
ifHCInDropCount value is less then the modifLinkDropThreshold
value for an interval of 1 second, after is was in a dropFault
condition."
::= { moduleTraps1 6 }
fcsFault NOTIFICATION-TYPE
OBJECTS
{ modifModIndex, modifName, modifUserLabel, moduleIndex }
STATUS current
DESCRIPTION
"A fcsFault trap signifies that the SNMP entity, acting in an
agent role, has detected that the FCS error count for the
interface has exceeded the threshold value for an interval of 1
second."
::= { moduleTraps1 7 }
fcsNormal NOTIFICATION-TYPE
OBJECTS
{ modifModIndex, modifName, modifUserLabel, moduleIndex }
STATUS current
DESCRIPTION
"A fcsNormal trap signifies that the SNMP entity, acting in an
agent role, has detected that the FCS error count for the
interface is less then the threshold value for an interval of 1
second, after it was in a fcsFault condition."
::= { moduleTraps1 8 }
remoteFault NOTIFICATION-TYPE
OBJECTS
{ modifModIndex, modifName, modifUserLabel, moduleIndex }
STATUS current
DESCRIPTION
"A remoteFault trap signifies that the SNMP entity, acting in
an agent role, has detected that the operational status for the
remote party has entered an invalid state."
::= { moduleTraps1 9 }
timestampConvDropFault NOTIFICATION-TYPE
OBJECTS
{ modifModIndex, modifName, modifUserLabel, moduleIndex }
STATUS obsolete
DESCRIPTION
"The Timestamp Conversion Module detected packets with
out-of-order timestamps.
These timestamps can corrupt Rotation File and were dropped for
security reasons. Please check your Timestamp Conversion
setting and your data source."
::= { moduleTraps1 10 }
timestampConvDropNormal NOTIFICATION-TYPE
OBJECTS
{ modifModIndex, modifName, modifUserLabel, moduleIndex }
STATUS obsolete
DESCRIPTION
"The Timestamp Conversion Module doesn't detect any
out-of-order packets for an interval of 1 second, after is was
in a timestampConvDropFault condition.
This could mean that all packet timestamps are in correct order
or no traffic is coming in."
::= { moduleTraps1 11 }
syncLoss NOTIFICATION-TYPE
OBJECTS
{ moduleIndex, moduleName }
STATUS current
DESCRIPTION
"A syncLoss trap signifies that the synchronization of the DAG
Module is lost."
::= { moduleTraps1 13 }
syncReturn NOTIFICATION-TYPE
OBJECTS
{ moduleIndex, moduleName }
STATUS current
DESCRIPTION
"A syncReturn trap signifies that the synchronization of the
DAG Module has returned after it was lost."
::= { moduleTraps1 14 }
inErrorFault NOTIFICATION-TYPE
OBJECTS
{ modifModIndex, modifName, modifUserLabel, moduleIndex }
STATUS current
DESCRIPTION
"An inErrorFault trap signifies that the SNMP entity, acting in
an agent role, has detected that the RX error count for the
interface has exceeded the threshold value for an interval of 1
second."
::= { moduleTraps1 15 }
inErrorNormal NOTIFICATION-TYPE
OBJECTS
{ modifModIndex, modifName, modifUserLabel, moduleIndex }
STATUS current
DESCRIPTION
"An inErrorNormal trap signifies that the SNMP entity, acting
in an agent role, has detected that the RX error count for the
interface is less then the threshold value for an interval of 1
second, after it was in an inErrorFault condition."
::= { moduleTraps1 16 }
-- compliance statements
moduleConformance OBJECT IDENTIFIER ::= { shogunModuleMIB 2 }
moduleGroups OBJECT IDENTIFIER ::= { moduleConformance 1 }
-- units of conformance
moduleControlGroup OBJECT-GROUP
OBJECTS
{ moduleIndex, moduleName, moduleType, moduleActiveFirmware,
moduleOperStatus, moduleLastChange }
STATUS current
DESCRIPTION
"A collection of objects providing information applicable to
controlling all modules.
The OIDs of objects may be reused in a later version of this
MIB."
::= { moduleGroups 1 }
ifControlGroup OBJECT-GROUP
OBJECTS
{ modifInAdminStatus, modifInOperStatus,
modifLinkUpDownTrapEnable, modifModIndex, modifModule, modifMtu,
modifName, modifPortLabel, modifSpeed, modifType,
modifUserLabel, modifPhysAddr }
STATUS current
DESCRIPTION
"A collection of objects providing information applicable to
all Interfaces."
::= { moduleGroups 2 }
ifInPacketGroup OBJECT-GROUP
OBJECTS
{ modifInOctets, modifInPackets, modifInDropPackets }
STATUS deprecated
DESCRIPTION
"A collection of objects providing ingress information for all
packet oriented network interfaces.
This group is deprecated since the counter size of 32bits is
not suitable for higher bandwidths."
::= { moduleGroups 3 }
ifOutPacketGroup OBJECT-GROUP
OBJECTS
{ modifOutPackets, modifOutOctets }
STATUS deprecated
DESCRIPTION
"A collection of objects providing egress information for all
packet orientated network interfaces.
This group is deprecated since the counter size of 32bits is
not suitable for higher bandwidths."
::= { moduleGroups 4 }
ifInHCPacketGroup OBJECT-GROUP
OBJECTS
{ modifHCInOctets, modifHCInPackets, modifHCInDropPackets,
modifHCInErrors }
STATUS current
DESCRIPTION
"A collection of objects providing ingress information for
high speed packet oriented network interfaces. A high speed
network is one that can transmit and receive at speeds greater
then 650,000,000 bits/second."
::= { moduleGroups 5 }
ifOutHCPacketGroup OBJECT-GROUP
OBJECTS
{ modifHCOutOctets, modifHCOutPackets }
STATUS current
DESCRIPTION
"A collection of objects providing egress information for high
speed packet oriented network interfaces. A high speed network
is one that can transmit and receive at speeds greater then
650,000,000 bits/second."
::= { moduleGroups 6 }
ifModCounterDiscontinuityGroup OBJECT-GROUP
OBJECTS
{ modifCounterDiscontinuityTime }
STATUS current
DESCRIPTION
"A collection of objects providing information specific to
interface counter discontinuities."
::= { moduleGroups 7 }
linkTrapsGroup NOTIFICATION-GROUP
NOTIFICATIONS
{ modlinkUp, modlinkDown }
STATUS current
DESCRIPTION
"A collection of objects providing information about link
status for all packet oriented network interfaces in the
system."
::= { moduleGroups 8 }
linkTrapsDrop NOTIFICATION-GROUP
NOTIFICATIONS
{ dropFault, dropNormal }
STATUS current
DESCRIPTION
"A collection of objects providing information about drop
counts for all packet oriented network interfaces in the
system."
::= { moduleGroups 9 }
linkTrapsErrors NOTIFICATION-GROUP
NOTIFICATIONS
{ fcsFault, fcsNormal, remoteFault, syncLoss, syncReturn }
STATUS current
DESCRIPTION
"A collection of objects providing information about
notifications raised when certain error conditions arise on a
module link."
::= { moduleGroups 10 }
modoptGroup OBJECT-GROUP
OBJECTS
{ modoptCompliance, modoptDetect, modoptLOS, modoptName,
modoptRxPower, modoptRxPowerOk, modoptTemp, modoptTempOk,
modoptTxPower, modoptTxPowerOk, modoptVolt, modoptVoltOk }
STATUS current
DESCRIPTION
"Group of all OID describing optical modules."
::= { moduleGroups 11 }
moduleTrapsState NOTIFICATION-GROUP
NOTIFICATIONS
{ inErrorFault, inErrorNormal }
STATUS current
DESCRIPTION
"A collection of objects providing information about
notifications raised when the module is in different states."
::= { moduleGroups 12 }
modulePhysStatusGroup OBJECT-GROUP
OBJECTS
{ moduleTemperature }
STATUS current
DESCRIPTION
"A collection of objects providing information applicable to
the physical status of a module."
::= { moduleGroups 16 }
timestampConvertNotifyGroup NOTIFICATION-GROUP
NOTIFICATIONS
{ timestampConvDropFault, timestampConvDropNormal }
STATUS obsolete
DESCRIPTION
"Timestamp conversion drops are only signaled, if the timestamp
conversion module, that convert converts incoming timestamps
into ERF timestamps detected packets that are out of order.
This is to protect Data Pipes and Rotation Files from getting
corrupted because of out-of-order timestamps."
::= { moduleGroups 17 }
obsoleteGroup OBJECT-GROUP
OBJECTS
{ modifHighSpeed, moduleSnapLen }
STATUS obsolete
DESCRIPTION
"This group collects all obsolete Objects."
::= { moduleGroups 18 }
moduleCompliances OBJECT IDENTIFIER ::= { moduleConformance 2 }
moduleCompliance1 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for Endace managed network entities
that have DAG modules."
MODULE ENDACE-MODULE-MIB
MANDATORY-GROUPS
{ ifControlGroup, ifInHCPacketGroup, ifOutHCPacketGroup,
linkTrapsDrop, linkTrapsGroup, moduleControlGroup }
GROUP obsoleteGroup
DESCRIPTION
"List of obsolete objects."
GROUP moduleTrapsState
DESCRIPTION
"This group is mandatory if the module has changed
operational state during operation."
GROUP linkTrapsErrors
DESCRIPTION
"This group is mandatory for those modules that support
certain error conditions on a per-link basis."
GROUP ifModCounterDiscontinuityGroup
DESCRIPTION
"This group is mandatory for those network interfaces that
are required to maintain counters (i.e., those for which
one of the ifPacketGroup or ifHCPacketGroup is
mandatory)."
GROUP timestampConvertNotifyGroup
DESCRIPTION
"This Notification group is obsolete:
Timestamp conversion drops are only signaled, if the
timestamp conversion module that convert converts incoming
timestamps into ERF timestamps detected packets that are
out of order.
This is to protect Data Pipes and Rotation Files from
getting corrupted because of out-of-order timestamps."
OBJECT modifLinkUpDownTrapEnable
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { moduleCompliances 1 }
END