- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
1370 lines
48 KiB
Text
1370 lines
48 KiB
Text
EQUIPMENT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
DateAndTime, TruthValue ,DisplayString,RowStatus
|
|
FROM SNMPv2-TC
|
|
PortList FROM Q-BRIDGE-MIB
|
|
swTimeRangeMgmtRangeName FROM TIMERANGE-MIB
|
|
AgentNotifyLevel, dlink-common-mgmt
|
|
FROM DLINK-ID-REC-MIB;
|
|
|
|
|
|
swEquipmentMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201104200000Z"
|
|
ORGANIZATION "D-Link Corp."
|
|
CONTACT-INFO
|
|
"http://support.dlink.com"
|
|
DESCRIPTION
|
|
" equipments MIB."
|
|
::= { dlink-common-mgmt 11 }
|
|
|
|
MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet address
|
|
-- in the
|
|
-- "canonical"
|
|
-- order, copy from RFC1493
|
|
|
|
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- OID Tree Allocation
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipment OBJECT IDENTIFIER ::= { swEquipmentMIB 1 }
|
|
swEquipmentNotify OBJECT IDENTIFIER ::= { swEquipmentMIB 2 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- Object Definition
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipmentCapacity OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
fanCapable(0),
|
|
--
|
|
redundantPowerCapable(1),
|
|
--
|
|
tempteratureDetection(2),
|
|
stackingCapable(3),
|
|
chassisCapable(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the equipment capability supported in the system."
|
|
|
|
::= { swEquipment 1 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swFanTrapState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicate the fan warning event trap state."
|
|
::= { swEquipment 4 }
|
|
|
|
swPowerTrapState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicate the power warning event trap state."
|
|
::= { swEquipment 5 }
|
|
|
|
swPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A list of power information values."
|
|
::= { swEquipment 6 }
|
|
|
|
swPowerEntry OBJECT-TYPE
|
|
SYNTAX SwPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of power information values."
|
|
INDEX { swPowerUnitIndex , swPowerID}
|
|
::= { swPowerTable 1 }
|
|
|
|
SwPowerEntry ::= SEQUENCE {
|
|
swPowerUnitIndex INTEGER,
|
|
swPowerID INTEGER,
|
|
swPowerStatus INTEGER
|
|
}
|
|
|
|
swPowerUnitIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the unit ID in the System."
|
|
::= { swPowerEntry 1 }
|
|
swPowerID OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates ID of the power
|
|
1 : main power
|
|
2 : redundant power ."
|
|
|
|
|
|
::= { swPowerEntry 2 }
|
|
|
|
swPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(0),
|
|
lowVoltage(1),
|
|
overCurrent(2),
|
|
working(3),
|
|
fail(4),
|
|
connect(5),
|
|
disconnect(6)
|
|
}
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current power status.
|
|
lowVoltage : The voltage of the power unit is too low.
|
|
overCurrent: The current of the power unit is too high.
|
|
working : The power unit is working normally.
|
|
fail : The power unit has failed.
|
|
connect : The power unit is connected but not powered on.
|
|
disconnect : The power unit is not connected."
|
|
::= { swPowerEntry 3 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swFanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A list of fan information values."
|
|
::= { swEquipment 7 }
|
|
|
|
swFanEntry OBJECT-TYPE
|
|
SYNTAX SwFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of fan information values."
|
|
INDEX { swFanUnitIndex, swFanID}
|
|
::= { swFanTable 1 }
|
|
|
|
SwFanEntry ::= SEQUENCE {
|
|
swFanUnitIndex INTEGER,
|
|
swFanID INTEGER,
|
|
swFanStatus INTEGER,
|
|
swFanPostion INTEGER,
|
|
swFanNumber INTEGER,
|
|
swFanSpeed INTEGER
|
|
}
|
|
|
|
swFanUnitIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the unit ID in the System."
|
|
::= { swFanEntry 1 }
|
|
swFanID OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the unit ID."
|
|
::= { swFanEntry 2 }
|
|
|
|
swFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(0),
|
|
working(1),
|
|
fail(2),
|
|
speed-0(3),
|
|
speed-low(4),
|
|
speed-middle(5),
|
|
speed-high(6)
|
|
}
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current fan status.
|
|
speed-0 : If the fan function is normal and the fan does not spin
|
|
due to the temperature not reaching the threshold,
|
|
the status of the fan is speed 0.
|
|
speed-low : Fan spin using the lowest speed.
|
|
speed-middle: Fan spin using the middle speed.
|
|
speed-high : Fan spin using the highest speed."
|
|
::= { swFanEntry 3 }
|
|
|
|
swFanPostion OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
left(2),
|
|
right(3),
|
|
back(4),
|
|
cpu(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the position of the fan."
|
|
::= { swFanEntry 4 }
|
|
swFanNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the fan number."
|
|
::= { swFanEntry 5 }
|
|
|
|
swFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the fan work speed(RPM)."
|
|
::= { swFanEntry 6 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swTemperatureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A list of temperature values."
|
|
::= { swEquipment 8 }
|
|
|
|
swTemperatureEntry OBJECT-TYPE
|
|
SYNTAX SwTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of temperature values."
|
|
INDEX { swTemperatureUnitIndex }
|
|
::= { swTemperatureTable 1 }
|
|
|
|
SwTemperatureEntry ::= SEQUENCE {
|
|
swTemperatureUnitIndex INTEGER,
|
|
swTemperatureCurrent INTEGER,
|
|
swTemperatureHighThresh INTEGER,
|
|
swTemperatureLowThresh INTEGER
|
|
}
|
|
|
|
swTemperatureUnitIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the unit ID in the System."
|
|
::= { swTemperatureEntry 1 }
|
|
|
|
swTemperatureCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER(-500..500)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The shelf current temperature."
|
|
::= { swTemperatureEntry 2 }
|
|
|
|
swTemperatureHighThresh OBJECT-TYPE
|
|
SYNTAX INTEGER (-500..500)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The high threshold of shelf temperature."
|
|
::= { swTemperatureEntry 3 }
|
|
|
|
swTemperatureLowThresh OBJECT-TYPE
|
|
SYNTAX INTEGER(-500..500)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The low threshold of shelf temperature."
|
|
::= { swTemperatureEntry 4 }
|
|
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swUnitMgmt OBJECT IDENTIFIER ::= { swEquipment 9 }
|
|
|
|
swUnitStackingVersion OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the version of this stacking system."
|
|
::= { swUnitMgmt 1 }
|
|
|
|
swUnitMaxSupportedUnits OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of units that are supported in the system."
|
|
::= { swUnitMgmt 2 }
|
|
|
|
swUnitNumOfUnit OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current number of units."
|
|
::= { swUnitMgmt 3 }
|
|
|
|
swUnitMgmtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwUnitMgmtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the unit information."
|
|
::= { swUnitMgmt 4 }
|
|
|
|
swUnitMgmtEntry OBJECT-TYPE
|
|
SYNTAX SwUnitMgmtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of management information for each unit in the system."
|
|
INDEX { swUnitMgmtId }
|
|
::= { swUnitMgmtTable 1 }
|
|
|
|
SwUnitMgmtEntry ::=
|
|
SEQUENCE {
|
|
swUnitMgmtId
|
|
INTEGER,
|
|
swUnitMgmtMacAddr
|
|
MacAddress,
|
|
swUnitMgmtStartPort
|
|
INTEGER,
|
|
swUnitMgmtPortRange
|
|
INTEGER,
|
|
swUnitMgmtFrontPanelLedStatus
|
|
OCTET STRING,
|
|
swUnitMgmtCtrlMode
|
|
INTEGER,
|
|
swUnitMgmtCurrentMode
|
|
INTEGER,
|
|
swUnitMgmtVersion
|
|
DisplayString,
|
|
swUnitMgmtModuleName
|
|
DisplayString,
|
|
swUnitMgmtPromVersion
|
|
DisplayString,
|
|
swUnitMgmtFirmwareVersion
|
|
DisplayString,
|
|
swUnitMgmtHardwareVersion
|
|
DisplayString,
|
|
swUnitMgmtPriority
|
|
INTEGER,
|
|
swUnitMgmtUserSetState
|
|
INTEGER,
|
|
swUnitMgmtExistState
|
|
INTEGER,
|
|
swUnitMgmtBoxId
|
|
INTEGER,
|
|
swUnitMgmtSerialNumber
|
|
DisplayString
|
|
}
|
|
|
|
swUnitMgmtId OBJECT-TYPE
|
|
SYNTAX INTEGER (1..13)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the specific entry in the stacking/chassis
|
|
table."
|
|
::= { swUnitMgmtEntry 1 }
|
|
|
|
swUnitMgmtMacAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAC address of this unit."
|
|
::= { swUnitMgmtEntry 2 }
|
|
|
|
swUnitMgmtStartPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the starting port of this unit."
|
|
::= { swUnitMgmtEntry 3 }
|
|
|
|
swUnitMgmtPortRange OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the total ports of this unit."
|
|
::= { swUnitMgmtEntry 4 }
|
|
|
|
swUnitMgmtFrontPanelLedStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a set of system LED indicators. The first four
|
|
octets are defined as a system LED. The first LED is a power LED.
|
|
The second LED in the stacking module is a master LED but in the chassis is
|
|
a status LED. The third LED is a console LED. The fourth LED is
|
|
an RPS (Redundancy Power Supply) LED. The other octets are the
|
|
logical port LED (following dot1dBasePort ordering). Every two
|
|
bytes are presented to a port. The first byte is presented as the
|
|
link/activity LED. The second byte is presented as the speed LED.
|
|
|
|
system LED:
|
|
01 = fail/error/non existence.
|
|
02 = work normal.
|
|
|
|
|
|
link/activity LED :
|
|
The most significant bit is used for blinking/solid:
|
|
8 = The LED blinks.
|
|
|
|
The second most significant bit is used for link status:
|
|
1 = link fail.
|
|
2 = link pass.
|
|
|
|
speed LED :
|
|
01 = 10Mbps.
|
|
02 = 100Mbps.
|
|
03 = 1000Mbps.
|
|
|
|
The four remaining bits are currently unused and must be set to 0.
|
|
|
|
Note:
|
|
For the DGS-3700, the first five octets are defined as the system LED.
|
|
The first LED is the power LED. The second LED is the console LED.
|
|
The third LED is the RPS (Redundancy Power Supply) LED. The fourth
|
|
LED is the management port LED. The fifth LED is the fan LED.
|
|
|
|
For the DGS-3200-10 and DGS-3200-16, the first three octets are defined
|
|
as the system LED. The first LED is the power LED. The second LED is the console LED.
|
|
The third LED is the RPS (Redundancy Power Supply) LED.
|
|
For the DGS-3200-24, the first three octets are defined as the system LED,
|
|
the definition of the first three octets is the same as the DGS-3200-10 and DGS-3200-16,
|
|
the fourth LED is the SD card LED. The following description is for the SD card LED:
|
|
01 = SD card is not present.
|
|
02 = SD card is present.
|
|
03 = fails to read/write SD card.
|
|
04 = read/write SD card successfully."
|
|
|
|
::= { swUnitMgmtEntry 5 }
|
|
|
|
|
|
swUnitMgmtCtrlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
auto(2),
|
|
stand-alone(3),
|
|
master(4),
|
|
slave(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the stacking mode the user configured for
|
|
the unit. This object can only be configured when the device is
|
|
in standalone mode.
|
|
|
|
other (1) - This object indicates the stacking mode that the user
|
|
has configured for the unit. This object can only be configured
|
|
when the device is in standalone mode.
|
|
auto (2) - The system will auto-assign a stacking role to this
|
|
unit to be: standalone(3), master(4), or slave(5).
|
|
standalone (3) - The unit is forced to be in standalone mode.
|
|
master (4) - The unit is forced to be in master mode. If this unit is
|
|
selected to be a master, the unit can modify the configuration of the stacking system.
|
|
slave (5) - The unit is forced to be in slave mode. If this unit is
|
|
selected to be a slave, it can only view the configuration of
|
|
the stacking system."
|
|
::= { swUnitMgmtEntry 6 }
|
|
|
|
swUnitMgmtCurrentMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
auto(2),
|
|
stand-alone(3),
|
|
master(4),
|
|
slave(5),
|
|
backup-master(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current stacking role of this unit."
|
|
::= { swUnitMgmtEntry 7 }
|
|
|
|
swUnitMgmtVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the version of this stacking unit."
|
|
::= { swUnitMgmtEntry 8 }
|
|
|
|
swUnitMgmtModuleName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing the stacking unit module name. "
|
|
::= { swUnitMgmtEntry 9 }
|
|
|
|
swUnitMgmtPromVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing the PROM version of the
|
|
stacking unit. "
|
|
::= { swUnitMgmtEntry 10 }
|
|
|
|
swUnitMgmtFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing the firmware version of the
|
|
stacking unit. "
|
|
::= { swUnitMgmtEntry 11 }
|
|
|
|
swUnitMgmtHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing the hardware version of the
|
|
stacking unit. "
|
|
::= { swUnitMgmtEntry 12 }
|
|
|
|
swUnitMgmtPriority OBJECT-TYPE
|
|
SYNTAX INTEGER(1..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Priority of the stacking unit. "
|
|
::= { swUnitMgmtEntry 13 }
|
|
|
|
swUnitMgmtUserSetState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
auto(2),
|
|
user(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the user set state of this unit."
|
|
::= { swUnitMgmtEntry 14 }
|
|
|
|
swUnitMgmtExistState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
exist(1),
|
|
no-exist(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of existence of this unit."
|
|
::= { swUnitMgmtEntry 15 }
|
|
|
|
swUnitMgmtBoxId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
box-1(1),
|
|
box-2(2),
|
|
box-3(3),
|
|
box-4(4),
|
|
box-5(5),
|
|
box-6(6),
|
|
box-7(7),
|
|
box-8(8),
|
|
box-9(9),
|
|
box-10(10),
|
|
box-11(11),
|
|
box-12(12),
|
|
auto(13)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The box ID of the stacking unit.
|
|
When show, it shows the current box ID of this unit;
|
|
When set, it sets the new box ID, and the new box ID will
|
|
take effect after the next boot."
|
|
::= { swUnitMgmtEntry 16 }
|
|
|
|
swUnitMgmtSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string containing the serial number of the stacking unit."
|
|
::= { swUnitMgmtEntry 17 }
|
|
|
|
swUnitTopology OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stand-alone(1),
|
|
duplex-chain(2),
|
|
duplex-ring(3),
|
|
star(4),
|
|
unstable(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The stacking topology state."
|
|
::= { swUnitMgmt 5 }
|
|
|
|
swUnitStackMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the stacking mode supported in the system."
|
|
::= { swUnitMgmt 6 }
|
|
|
|
swUnitStackForceMasterRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the stack force master role mode supported in the system."
|
|
::= { swUnitMgmt 7 }
|
|
|
|
swUnitStackTrapState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the stacking trap state."
|
|
DEFVAL {enabled}
|
|
::= { swUnitMgmt 8 }
|
|
|
|
swUnitStackLogState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the stacking log state."
|
|
DEFVAL {enabled}
|
|
::= { swUnitMgmt 9 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- swExternalAlarmMgmt
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
swExternalAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwExternalAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of the status of each of the alarm channels by this agent."
|
|
::= { swEquipment 10 }
|
|
|
|
swExternalAlarmEntry OBJECT-TYPE
|
|
SYNTAX SwExternalAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects with the status of each alarm channel."
|
|
INDEX { swExternalAlarmChannel }
|
|
::= { swExternalAlarmTable 1 }
|
|
|
|
SwExternalAlarmEntry ::=
|
|
SEQUENCE {
|
|
swExternalAlarmChannel
|
|
INTEGER,
|
|
swExternalAlarmMessage
|
|
DisplayString,
|
|
swExternalAlarmStatus
|
|
INTEGER
|
|
}
|
|
|
|
swExternalAlarmChannel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the alarm channel."
|
|
::= { swExternalAlarmEntry 1 }
|
|
|
|
swExternalAlarmMessage OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to configure the alarm message when an alarm occurs on this channel.
|
|
If no alarm message is configured on this channel, a default alarm message will be generated."
|
|
::= { swExternalAlarmEntry 2 }
|
|
|
|
swExternalAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarming(1),
|
|
normal(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the current status of each alarm channel."
|
|
::= { swExternalAlarmEntry 3 }
|
|
|
|
-- --------------------------------------------------------------------------------
|
|
-- swEquipmentPowerSaving
|
|
-- --------------------------------------------------------------------------------
|
|
swEquipmentPowerSaving OBJECT IDENTIFIER ::= { swEquipment 11 }
|
|
|
|
swEquipPowerSavingLinkDetectState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the equipment reduced power consumption state."
|
|
::= { swEquipmentPowerSaving 1 }
|
|
|
|
swEquipPowerSavingLenDetect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the equipment reduced power consumption state with a link partner."
|
|
::= { swEquipmentPowerSaving 2 }
|
|
|
|
swEquipPowerSavingHiberState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the power saving state of system hibernation."
|
|
DEFVAL {disabled}
|
|
::= { swEquipmentPowerSaving 3 }
|
|
|
|
swEquipPowerSavingPortLEDState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the power saving state of port LED."
|
|
DEFVAL {disabled}
|
|
::= { swEquipmentPowerSaving 4 }
|
|
|
|
swEquipPowerSavingPortState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the power saving state of port."
|
|
DEFVAL {disabled}
|
|
::= { swEquipmentPowerSaving 5 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipPowerSavingScheduleCtrl OBJECT IDENTIFIER ::= { swEquipmentPowerSaving 6 }
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipPowerSavingHibernationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwEquipPowerSavingHibernationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of the system hibernation configurations of the power saving."
|
|
::= { swEquipPowerSavingScheduleCtrl 1 }
|
|
|
|
swEquipPowerSavingHibernationEntry OBJECT-TYPE
|
|
SYNTAX SwEquipPowerSavingHibernationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing the system hibernation configurations of the power saving."
|
|
INDEX { swTimeRangeMgmtRangeName }
|
|
::= { swEquipPowerSavingHibernationTable 1 }
|
|
|
|
SwEquipPowerSavingHibernationEntry ::=
|
|
SEQUENCE {
|
|
swEquipPowerSavingHiberRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
swEquipPowerSavingHiberRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of this entry."
|
|
::= { swEquipPowerSavingHibernationEntry 100 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipPowerSavingPortLedTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwEquipPowerSavingPortLedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of the port LED configurations of the power saving."
|
|
::= { swEquipPowerSavingScheduleCtrl 2 }
|
|
|
|
swEquipPowerSavingPortLedEntry OBJECT-TYPE
|
|
SYNTAX SwEquipPowerSavingPortLedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing the port LED configurations of the power saving."
|
|
INDEX { swTimeRangeMgmtRangeName}
|
|
::= { swEquipPowerSavingPortLedTable 1 }
|
|
|
|
SwEquipPowerSavingPortLedEntry ::=
|
|
SEQUENCE {
|
|
swEquipPowerSavingPortLedRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
swEquipPowerSavingPortLedRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of this entry."
|
|
::= { swEquipPowerSavingPortLedEntry 100 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipPowerSavingPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwEquipPowerSavingPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of the port configurations of the power saving."
|
|
::= { swEquipPowerSavingScheduleCtrl 3 }
|
|
|
|
swEquipPowerSavingPortEntry OBJECT-TYPE
|
|
SYNTAX SwEquipPowerSavingPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing the port configurations of the power saving."
|
|
INDEX { swEquipPowerSavingPortIndex, swTimeRangeMgmtRangeName }
|
|
::= { swEquipPowerSavingPortTable 1 }
|
|
|
|
SwEquipPowerSavingPortEntry ::=
|
|
SEQUENCE {
|
|
swEquipPowerSavingPortIndex
|
|
INTEGER,
|
|
swEquipPowerSavingPortRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
swEquipPowerSavingPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the module's port number.(1..Max port number in
|
|
the module)."
|
|
::= { swEquipPowerSavingPortEntry 1 }
|
|
|
|
swEquipPowerSavingPortRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of this entry."
|
|
::= { swEquipPowerSavingPortEntry 100 }
|
|
|
|
-- --------------------------------------------------------------------------------
|
|
-- swEquipEeeMgmt
|
|
-- --------------------------------------------------------------------------------
|
|
swEquipEeeMgmt OBJECT IDENTIFIER ::= { swEquipmentPowerSaving 20 }
|
|
|
|
swEquipEeeState OBJECT-TYPE
|
|
SYNTAX PortList
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the EEE state of all ports.
|
|
|
|
Note:
|
|
If the port's bit has a value of '1', specifies the EEE (Energy Efficient Ethernet)
|
|
state of this port is 'Enabled',
|
|
otherwise, if the port's bit has a value of '0', specifies the EEE
|
|
state of this port is 'Disabled'."
|
|
::= { swEquipEeeMgmt 1 }
|
|
|
|
-- --------------------------------------------------------------------------------
|
|
-- swEquipmentTemperatureCtrl
|
|
-- --------------------------------------------------------------------------------
|
|
swEquipmentTemperatureCtrl OBJECT IDENTIFIER ::= { swEquipment 12 }
|
|
|
|
swTemperatureTrapState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object can enable or disable the warning temperature trap."
|
|
::= { swEquipmentTemperatureCtrl 1 }
|
|
|
|
swTemperatureLogState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object can enable or disable the warning temperature log."
|
|
::= { swEquipmentTemperatureCtrl 2 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- swEquipmentLEDCtrl OBJECT IDENTIFIER ::= { swEquipment 13 }
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipmentLEDCtrl OBJECT IDENTIFIER ::= { swEquipment 13 }
|
|
|
|
swEquipmentPortLEDState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the LED admin state of all ports."
|
|
DEFVAL {enabled}
|
|
::= { swEquipmentLEDCtrl 1 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- swExternalAlarmStackingMgmt
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
swExternalAlarmStackingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwExternalAlarmStackingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of the status of each of the alarm channels by this agent."
|
|
::= { swEquipment 15 }
|
|
|
|
swExternalAlarmStackingEntry OBJECT-TYPE
|
|
SYNTAX SwExternalAlarmStackingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects with the status of each alarm channel."
|
|
INDEX { swExternalAlarmStackingUnitIndex, swExternalAlarmStackingChannel }
|
|
::= { swExternalAlarmStackingTable 1 }
|
|
|
|
SwExternalAlarmStackingEntry ::=
|
|
SEQUENCE {
|
|
swExternalAlarmStackingUnitIndex
|
|
INTEGER,
|
|
swExternalAlarmStackingChannel
|
|
INTEGER,
|
|
swExternalAlarmStackingMessage
|
|
DisplayString,
|
|
swExternalAlarmStackingStatus
|
|
INTEGER
|
|
}
|
|
|
|
swExternalAlarmStackingUnitIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the unit ID in the System.."
|
|
::= { swExternalAlarmStackingEntry 1 }
|
|
|
|
swExternalAlarmStackingChannel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the alarm channel."
|
|
::= { swExternalAlarmStackingEntry 2 }
|
|
|
|
swExternalAlarmStackingMessage OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to configure the alarm message when an alarm occurs on this channel.
|
|
If no alarm message is configured on this channel, a default alarm message will be generated."
|
|
::= { swExternalAlarmStackingEntry 3 }
|
|
|
|
swExternalAlarmStackingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarming(1),
|
|
normal(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the current status of each alarm channel."
|
|
::= { swExternalAlarmStackingEntry 4 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipmentNotifyMgmt OBJECT IDENTIFIER ::= { swEquipmentNotify 1 }
|
|
swEquipmentNotification OBJECT IDENTIFIER ::= { swEquipmentNotify 2 }
|
|
|
|
|
|
swEquipUnitNotification OBJECT IDENTIFIER ::= { swEquipmentNotification 1 }
|
|
swEquipPowerNotification OBJECT IDENTIFIER ::= { swEquipmentNotification 2 }
|
|
swEquipFanNotification OBJECT IDENTIFIER ::= { swEquipmentNotification 3 }
|
|
swEquipTemperatureNotification OBJECT IDENTIFIER ::= { swEquipmentNotification 4 }
|
|
swEquipExternalAlarmNotification OBJECT IDENTIFIER ::= { swEquipmentNotification 5 }
|
|
|
|
swEquipUnitNotifyMgmt OBJECT IDENTIFIER ::= { swEquipmentNotifyMgmt 1 }
|
|
swEquipPowerNotifyMgmt OBJECT IDENTIFIER ::= { swEquipmentNotifyMgmt 2 }
|
|
swEquipFanNotifyMgmt OBJECT IDENTIFIER ::= { swEquipmentNotifyMgmt 3 }
|
|
swEquipTemperatureNotifyMgmt OBJECT IDENTIFIER ::= { swEquipmentNotifyMgmt 4 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swUnitInsertSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swUnitInsert detection level."
|
|
::= { swEquipUnitNotifyMgmt 1 }
|
|
|
|
swUnitRemoveSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swUnitRemove detection level."
|
|
::= { swEquipUnitNotifyMgmt 2 }
|
|
|
|
swUnitFailureSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swUnitFailure detection level."
|
|
::= { swEquipUnitNotifyMgmt 3 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swPowerStatusChgSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swPowerStatusChg detection level."
|
|
::= { swEquipPowerNotifyMgmt 1 }
|
|
|
|
swPowerFailureSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swPowerFailure detection level."
|
|
::= { swEquipPowerNotifyMgmt 2 }
|
|
|
|
swPowerRecoverSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swPowerRecover detection level."
|
|
::= { swEquipPowerNotifyMgmt 3 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swFanFailureSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swFanFailure detection level."
|
|
::= { swEquipFanNotifyMgmt 1 }
|
|
|
|
swFanRecoverSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swFanRecover detection level."
|
|
::= { swEquipFanNotifyMgmt 2 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swHighTemperatureSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swHighTemperature detection level."
|
|
::= { swEquipTemperatureNotifyMgmt 1 }
|
|
|
|
swHighTemperatureRecoverSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swHighTemperatureRecover detection level."
|
|
::= { swEquipTemperatureNotifyMgmt 2 }
|
|
|
|
swLowTemperatureSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swLowTemperature detection level."
|
|
::= { swEquipTemperatureNotifyMgmt 3 }
|
|
|
|
swLowTemperatureRecoverSeverity OBJECT-TYPE
|
|
SYNTAX AgentNotifyLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the swLowTemperatureRecover detection level."
|
|
::= { swEquipTemperatureNotifyMgmt 4 }
|
|
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipUnitNotifyPrefix OBJECT IDENTIFIER ::= { swEquipUnitNotification 0 }
|
|
|
|
swUnitInsert NOTIFICATION-TYPE
|
|
OBJECTS { swUnitMgmtId,
|
|
swUnitMgmtMacAddr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Unit Hot Insert notification."
|
|
::= { swEquipUnitNotifyPrefix 1 }
|
|
|
|
swUnitRemove NOTIFICATION-TYPE
|
|
OBJECTS { swUnitMgmtId,
|
|
swUnitMgmtMacAddr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Unit Hot Remove notification."
|
|
::= { swEquipUnitNotifyPrefix 2 }
|
|
|
|
swUnitFailure NOTIFICATION-TYPE
|
|
OBJECTS { swUnitMgmtId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Unit Failure notification."
|
|
::= { swEquipUnitNotifyPrefix 3 }
|
|
|
|
swUnitTPChange NOTIFICATION-TYPE
|
|
OBJECTS { swStackTopologyType,
|
|
swUnitMgmtId,
|
|
swUnitMgmtMacAddr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The stacking topology change notification."
|
|
::= { swEquipUnitNotifyPrefix 4 }
|
|
|
|
swUnitRoleChange NOTIFICATION-TYPE
|
|
OBJECTS { swStackRoleChangeType,
|
|
swUnitMgmtId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The stacking unit role change notification."
|
|
::= { swEquipUnitNotifyPrefix 5 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipPowerNotifyPerfix OBJECT IDENTIFIER ::= { swEquipPowerNotification 0 }
|
|
|
|
swPowerStatusChg NOTIFICATION-TYPE
|
|
OBJECTS { swPowerUnitIndex,
|
|
swPowerID,
|
|
swPowerStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power Status change notification. The notification is issued
|
|
when the swPowerStatus changes in the following cases:
|
|
lowVoltage -> overCurrent.
|
|
lowVoltage -> working.
|
|
lowVoltage -> disconnect.
|
|
lowVoltage -> connect.
|
|
overCurrent -> lowVoltage.
|
|
overCurrent -> working.
|
|
overCurrent -> disconnect.
|
|
overCurrent -> connect.
|
|
working -> lowVoltage.
|
|
working -> overCurrent.
|
|
working -> connect.
|
|
working -> disconnect.
|
|
fail -> connect.
|
|
fail -> disconnect.
|
|
connect -> lowVoltage.
|
|
connect -> overCurrent.
|
|
connect -> working.
|
|
connect -> disconnect.
|
|
disconnect -> lowVoltage.
|
|
disconnect -> overCurrent.
|
|
disconnect -> working.
|
|
disconnect -> connect."
|
|
::= { swEquipPowerNotifyPerfix 1 }
|
|
|
|
|
|
swPowerFailure NOTIFICATION-TYPE
|
|
OBJECTS { swPowerUnitIndex,
|
|
swPowerID,
|
|
swPowerStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power Failure notification. The notification is issued
|
|
when the swPowerStatus changes in the following cases:
|
|
lowVoltage -> fail.
|
|
overCurrent -> fail.
|
|
working -> fail.
|
|
connect -> fail.
|
|
disconnect -> fail."
|
|
::= { swEquipPowerNotifyPerfix 2 }
|
|
|
|
swPowerRecover NOTIFICATION-TYPE
|
|
OBJECTS {swPowerUnitIndex,
|
|
swPowerID,
|
|
swPowerStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power Recover notification. The notification is issued
|
|
when the swPowerStatus changes in the following cases:
|
|
fail -> lowVoltage.
|
|
fail -> overCurrent.
|
|
fail -> working."
|
|
::= { swEquipPowerNotifyPerfix 3 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipFanNotifyPrefix OBJECT IDENTIFIER ::= { swEquipFanNotification 0 }
|
|
|
|
swFanFailure NOTIFICATION-TYPE
|
|
OBJECTS { swFanUnitIndex,
|
|
swFanID
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan Failure notification."
|
|
::= { swEquipFanNotifyPrefix 1 }
|
|
|
|
swFanRecover NOTIFICATION-TYPE
|
|
OBJECTS { swFanUnitIndex,
|
|
swFanID
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fan Recover notification."
|
|
::= { swEquipFanNotifyPrefix 2 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipTemperatureNotifyPrefix OBJECT IDENTIFIER ::= { swEquipTemperatureNotification 0 }
|
|
|
|
swHighTemperature NOTIFICATION-TYPE
|
|
OBJECTS { swTemperatureUnitIndex,
|
|
swTemperSensorID,
|
|
swTemperatureCurrent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High Temperature notification."
|
|
::= { swEquipTemperatureNotifyPrefix 1 }
|
|
|
|
swHighTemperatureRecover NOTIFICATION-TYPE
|
|
OBJECTS { swTemperatureUnitIndex,
|
|
swTemperSensorID,
|
|
swTemperatureCurrent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High Temperature notification."
|
|
::= { swEquipTemperatureNotifyPrefix 2 }
|
|
|
|
swLowTemperature NOTIFICATION-TYPE
|
|
OBJECTS { swTemperatureUnitIndex,
|
|
swTemperSensorID,
|
|
swTemperatureCurrent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low Temperature notification."
|
|
::= { swEquipTemperatureNotifyPrefix 3 }
|
|
|
|
swLowTemperatureRecover NOTIFICATION-TYPE
|
|
OBJECTS { swTemperatureUnitIndex,
|
|
swTemperSensorID,
|
|
swTemperatureCurrent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low Temperature notification."
|
|
::= { swEquipTemperatureNotifyPrefix 4 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
swEquipExternalAlarmNotifyPrefix OBJECT IDENTIFIER ::= { swEquipExternalAlarmNotification 0 }
|
|
|
|
swExternalAlarm NOTIFICATION-TYPE
|
|
OBJECTS { swExternalAlarmChannel,
|
|
swExternalAlarmMessage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The notice of an Alarm in the specified channel."
|
|
|
|
::= { swEquipExternalAlarmNotifyPrefix 1 }
|
|
|
|
swExternalAlarmStacking NOTIFICATION-TYPE
|
|
OBJECTS { swExternalAlarmStackingUnitIndex,
|
|
swExternalAlarmStackingChannel,
|
|
swExternalAlarmStackingMessage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The notice of an Alarm in the specified channel."
|
|
::= { swEquipExternalAlarmNotifyPrefix 2 }
|
|
--- -----------------------------------------------------------------------------
|
|
swNotificationBindings OBJECT IDENTIFIER ::= { swEquipmentNotify 3 }
|
|
|
|
|
|
--- -----------------------------------------------------------------------------
|
|
swEquipTemperNotifyBindings OBJECT IDENTIFIER ::= { swNotificationBindings 1 }
|
|
|
|
swTemperSensorID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the ID of the temperature sensor in the unit."
|
|
::= { swEquipTemperNotifyBindings 1 }
|
|
|
|
swEquipUnitNotifyBindings OBJECT IDENTIFIER ::= { swNotificationBindings 2 }
|
|
|
|
swStackTopologyType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
chain(1),
|
|
ring(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the MAC address of the switch."
|
|
::= { swEquipUnitNotifyBindings 1 }
|
|
|
|
swStackRoleChangeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
backup-to-master(1),
|
|
slave-to-master(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the role information of the switch."
|
|
::= { swEquipUnitNotifyBindings 2 }
|
|
|
|
|
|
END
|