- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
510 lines
16 KiB
Text
510 lines
16 KiB
Text
--
|
|
-- Accedian Enterprise Specific MIB: Structure of Management Information
|
|
--
|
|
-- Copyright (c) 2005-2011, Accedian Networks, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- The contents of this document are subject to change without notice.
|
|
--
|
|
|
|
|
|
ACD-ALARM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DisplayString, TruthValue, DateAndTime
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
sysName
|
|
FROM SNMPv2-MIB
|
|
acdMibs
|
|
FROM ACCEDIAN-SMI;
|
|
|
|
acdAlarm MODULE-IDENTITY
|
|
|
|
LAST-UPDATED "201110100100Z"
|
|
ORGANIZATION "Accedian Networks, Inc."
|
|
CONTACT-INFO
|
|
"Accedian Technical Assistance Center
|
|
Accedian Networks, Inc.
|
|
4878 Levy, suite 202
|
|
Saint-Laurent, Quebec Canada H4R 2P1
|
|
E-mail: support@accedian.com"
|
|
DESCRIPTION
|
|
"The alarm Table for this Accedian Networks device."
|
|
|
|
REVISION "201110100100Z" -- 10 October 2011
|
|
DESCRIPTION
|
|
"Add acdAlarmCfgTableLastChangeTid and
|
|
acdAlarmStatusTableLastChangeTid."
|
|
|
|
REVISION "201011100100Z" -- 10 November 2010
|
|
DESCRIPTION
|
|
"Fix compliance section."
|
|
|
|
REVISION "200902040100Z" -- 4 Feb 2009
|
|
DESCRIPTION
|
|
"Add new fields in acdAlarmCfgEntry, acdAlarmActiveState and
|
|
acdAlarmClearState."
|
|
|
|
REVISION "200802010100Z" -- 1 Feb 2008
|
|
DESCRIPTION
|
|
"Add UNITS clause to object, where appropriate."
|
|
|
|
REVISION "200705220100Z" -- 22 May 2007
|
|
DESCRIPTION
|
|
"Add acdAlarmCfgNumber object to Alarm traps."
|
|
|
|
REVISION "200612190100Z" -- 19 Dec 2006
|
|
DESCRIPTION
|
|
"Add 802.3AH notification enable and msg field in status table."
|
|
|
|
REVISION "200608060100Z" -- 6 Aug 2006
|
|
DESCRIPTION
|
|
"Initial version of MIB module ACD-ALARM-MIB."
|
|
|
|
::= { acdMibs 1 }
|
|
|
|
acdAlarmMIBObjects OBJECT IDENTIFIER ::= { acdAlarm 15 }
|
|
acdAlarmConfig OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 1 }
|
|
acdAlarmStatus OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 2 }
|
|
acdAlarmConformance OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 3 }
|
|
|
|
acdAlarmTableTid OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 4 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- Alarm General configuration
|
|
---------------------------------------------------------------------------
|
|
acdAlarmGenThreshOn OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..50000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value represents the Alarm On Hysteris. This is the time since the
|
|
detection of the On event inside the system versus the report. This is
|
|
to avoid storm of notifications."
|
|
::= { acdAlarm 1 }
|
|
|
|
acdAlarmGenThreshOff OBJECT-TYPE
|
|
SYNTAX Unsigned32 (500..50000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value represents the Alarm Off Hysteris. This is the time since the
|
|
detection of the Off event inside the system versus the report. This is
|
|
to avoid storm of notifications."
|
|
::= { acdAlarm 2 }
|
|
|
|
acdAlarmGenLedEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to Enable the alarms reporting through the LEDs."
|
|
::= { acdAlarm 3 }
|
|
|
|
acdAlarmGenSyslogEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to Enable the alarms reporting through the syslog system."
|
|
::= { acdAlarm 4 }
|
|
|
|
acdAlarmGenSNMPEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to Enable the alarms reporting through the SNMP agent."
|
|
::= { acdAlarm 5 }
|
|
|
|
acdAlarmGen8023AHEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to Enable the alarms reporting through the 802.3AH protocol."
|
|
::= { acdAlarm 6 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- The Alarm configuration table
|
|
-- This table contains the configuration for each alarm.
|
|
---------------------------------------------------------------------------
|
|
|
|
acdAlarmCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcdAlarmCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of all alarms."
|
|
::= { acdAlarm 10 }
|
|
|
|
acdAlarmCfgEntry OBJECT-TYPE
|
|
SYNTAX AcdAlarmCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An alarm is an exceptional event that requires user notificaton."
|
|
INDEX { acdAlarmCfgID }
|
|
::= { acdAlarmCfgTable 1 }
|
|
|
|
AcdAlarmCfgEntry ::= SEQUENCE {
|
|
acdAlarmCfgID Unsigned32,
|
|
acdAlarmCfgNumber Unsigned32,
|
|
acdAlarmCfgDesc DisplayString,
|
|
acdAlarmCfgEnable TruthValue,
|
|
acdAlarmCfgSeverity INTEGER,
|
|
acdAlarmCfgServiceAffecting TruthValue,
|
|
acdAlarmCfgExtNumber DisplayString,
|
|
acdAlarmCfgConditionType DisplayString,
|
|
acdAlarmCfgAMOType DisplayString
|
|
|
|
}
|
|
|
|
acdAlarmCfgID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique value for each alarm. Its value ranges from 1 to
|
|
MAXINT (4 bytes). "
|
|
::= { acdAlarmCfgEntry 1 }
|
|
|
|
acdAlarmCfgNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique number that identifies this alarm. Assigned by the unit. The
|
|
alarm identifier is compose of 3 fields, the module number, the instance
|
|
number and the error number. The alarm number looks like this:
|
|
A.BBB.CC and is expressed in decimal, A is the module number, BBB is
|
|
the instance number (1-999) and CC is the error number (1-99). A module
|
|
number is assigned for each source of alarm in the system. For example
|
|
the port module is set to 1, the SFP module is set to 2, the PAA is set
|
|
to 3 and the environmental is set to 8."
|
|
::= { acdAlarmCfgEntry 2 }
|
|
|
|
acdAlarmCfgDesc OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This string is to describe the alarm in a readable way, e.g.:
|
|
+5Vdc Power supply fail."
|
|
::= { acdAlarmCfgEntry 3 }
|
|
|
|
acdAlarmCfgEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to indicate if the alarm is reported or not."
|
|
::= { acdAlarmCfgEntry 4 }
|
|
|
|
acdAlarmCfgSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
info(0),
|
|
minor(1),
|
|
major(2),
|
|
critical(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Accedian Networks classifies alarms into four severity types. These types
|
|
and their associated decimal codes are, informational(0), minor(1),
|
|
major(2) and critical(3)."
|
|
::= { acdAlarmCfgEntry 5 }
|
|
|
|
acdAlarmCfgServiceAffecting OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to indicate if the alarm is service affecting or not. This
|
|
value depends on the utilization of the box. For instance in an
|
|
application where the monitoring of the traffic is mandatory the link
|
|
down event on the monitor port is service affecting."
|
|
::= { acdAlarmCfgEntry 6 }
|
|
|
|
acdAlarmCfgExtNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique number that identifies this alarm. Assigned by the unit. The
|
|
alarm identifier is compose of 3 fields, the module number, the instance
|
|
number and the error number. The alarm number looks like this:
|
|
A.B.C and is expressed in decimal, A is the module number, B is
|
|
the instance number and C is the error number. A module number is
|
|
assigned for each source of alarm in the system (see Accedian
|
|
documentation for more detail)."
|
|
::= { acdAlarmCfgEntry 7 }
|
|
|
|
acdAlarmCfgConditionType OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the type of alarm condition."
|
|
::= { acdAlarmCfgEntry 8 }
|
|
|
|
acdAlarmCfgAMOType OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the Alarm Maintenance Object."
|
|
::= { acdAlarmCfgEntry 9 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- The Alarms Status table
|
|
-- This table contains the status of all alarms.
|
|
---------------------------------------------------------------------------
|
|
|
|
acdAlarmStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcdAlarmStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of all alarms"
|
|
::= { acdAlarm 11 }
|
|
|
|
acdAlarmStatusEntry OBJECT-TYPE
|
|
SYNTAX AcdAlarmStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An alarm is an exceptional event that requires user notificaton."
|
|
INDEX { acdAlarmStatusID }
|
|
::= { acdAlarmStatusTable 1 }
|
|
|
|
AcdAlarmStatusEntry ::= SEQUENCE {
|
|
acdAlarmStatusID Unsigned32,
|
|
acdAlarmStatusNumber Unsigned32,
|
|
acdAlarmStatusOn TruthValue,
|
|
acdAlarmStatusLastChange DateAndTime,
|
|
acdAlarmStatusMsg DisplayString
|
|
}
|
|
|
|
acdAlarmStatusID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique value for each alarm. Its value ranges from 1 to
|
|
MAXINT (4 bytes). "
|
|
::= { acdAlarmStatusEntry 1 }
|
|
|
|
acdAlarmStatusNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique number that identifies this alarm. Assigned by the unit. The
|
|
alarm identifier is compose of 3 fields, the module number, the instance
|
|
number and the error number. The alarm number looks like this:
|
|
AAA.BBB.CC and is expressed in decimal, AAA is the module number, BBB is
|
|
the instance number (1-999) and CC is the error number (1-99). A module
|
|
number is assigned for each source of alarm in the system. For example
|
|
the port module is set to 1, the SFP module is set to 2, the PAA is set
|
|
to 3 and the environmental is set to 8."
|
|
::= { acdAlarmStatusEntry 2 }
|
|
|
|
acdAlarmStatusOn OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is to indicate if the alarm is On or Off."
|
|
::= { acdAlarmStatusEntry 3 }
|
|
|
|
acdAlarmStatusLastChange OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the time of the last change for this alarm. A value of zero
|
|
means that nothing happened to this alarm since the last reboot."
|
|
::= { acdAlarmStatusEntry 4 }
|
|
|
|
acdAlarmStatusMsg OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This string is to add information why the alarm is reported."
|
|
::= { acdAlarmStatusEntry 5 }
|
|
|
|
-- Accedian Alarm Traps
|
|
---------------------------------------------------------------------------
|
|
-- DESCRIPTION "Definition point for Accedian Alarm notifications."
|
|
---------------------------------------------------------------------------
|
|
|
|
acdAlarmV2 OBJECT IDENTIFIER ::= { acdAlarm 12 }
|
|
|
|
acdAlarmActiveState NOTIFICATION-TYPE
|
|
OBJECTS { acdAlarmCfgID,
|
|
acdAlarmCfgNumber,
|
|
acdAlarmCfgSeverity,
|
|
acdAlarmCfgServiceAffecting,
|
|
acdAlarmCfgDesc,
|
|
acdAlarmStatusLastChange,
|
|
acdAlarmCfgExtNumber,
|
|
acdAlarmCfgConditionType,
|
|
acdAlarmCfgAMOType,
|
|
sysName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP trap that is generated when an alarm
|
|
entry crosses its rising threshold and generates
|
|
an event that is configured for sending SNMP
|
|
traps."
|
|
|
|
::= { acdAlarmV2 1 }
|
|
|
|
acdAlarmClearState NOTIFICATION-TYPE
|
|
OBJECTS { acdAlarmCfgID,
|
|
acdAlarmCfgNumber,
|
|
acdAlarmCfgSeverity,
|
|
acdAlarmCfgServiceAffecting,
|
|
acdAlarmCfgDesc,
|
|
acdAlarmStatusLastChange,
|
|
acdAlarmCfgExtNumber,
|
|
acdAlarmCfgConditionType,
|
|
acdAlarmCfgAMOType,
|
|
sysName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP trap that is generated when an alarm
|
|
entry crosses its falling threshold and generates
|
|
an event that is configured for sending SNMP
|
|
traps."
|
|
|
|
::= { acdAlarmV2 2 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- Transaction ID Information
|
|
---------------------------------------------------------------------------
|
|
|
|
acdAlarmCfgTableLastChangeTid OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the transaction ID of the last change of the acdAlarmCfgTable
|
|
table. If this value is different since the last read this is indicate
|
|
a table change."
|
|
::= { acdAlarmTableTid 1 }
|
|
|
|
acdAlarmStatusTableLastChangeTid OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the transaction ID of the last change of the acdAlarmStatusTable
|
|
table. If this value is different since the last read this is indicate
|
|
a table change."
|
|
::= { acdAlarmTableTid 2 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- ACD-ALARM-MIB Module - Conformance Information
|
|
---------------------------------------------------------------------------
|
|
|
|
acdAlarmCompliances OBJECT IDENTIFIER ::= { acdAlarmConformance 1 }
|
|
acdAlarmGroups OBJECT IDENTIFIER ::= { acdAlarmConformance 2 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- Units of conformance
|
|
---------------------------------------------------------------------------
|
|
|
|
acdAlarmGenGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
acdAlarmGenThreshOn,
|
|
acdAlarmGenThreshOff,
|
|
acdAlarmGenLedEnable,
|
|
acdAlarmGenSyslogEnable,
|
|
acdAlarmGenSNMPEnable,
|
|
acdAlarmGen8023AHEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
::= { acdAlarmGroups 1 }
|
|
|
|
acdAlarmCfgGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
acdAlarmCfgID,
|
|
acdAlarmCfgNumber,
|
|
acdAlarmCfgDesc,
|
|
acdAlarmCfgEnable,
|
|
acdAlarmCfgSeverity,
|
|
acdAlarmCfgServiceAffecting,
|
|
acdAlarmCfgExtNumber,
|
|
acdAlarmCfgConditionType,
|
|
acdAlarmCfgAMOType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
::= { acdAlarmGroups 2 }
|
|
|
|
acdAlarmStatusGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
acdAlarmStatusID,
|
|
acdAlarmStatusNumber,
|
|
acdAlarmStatusOn,
|
|
acdAlarmStatusLastChange,
|
|
acdAlarmStatusMsg
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
::= { acdAlarmGroups 3 }
|
|
|
|
acdAlarmNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
acdAlarmActiveState,
|
|
acdAlarmClearState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects for the Notifications group."
|
|
::= { acdAlarmGroups 4 }
|
|
|
|
acdAlarmTidGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
acdAlarmCfgTableLastChangeTid,
|
|
acdAlarmStatusTableLastChangeTid
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of scalars to monitior changes in tables."
|
|
::= { acdAlarmGroups 5 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- MIB Module Compliance statements
|
|
---------------------------------------------------------------------------
|
|
acdAlarmCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for support of the ACD-ALARM-MIB module."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
acdAlarmGenGroup,
|
|
acdAlarmCfgGroup,
|
|
acdAlarmStatusGroup,
|
|
acdAlarmNotificationsGroup,
|
|
acdAlarmTidGroup
|
|
}
|
|
|
|
::= { acdAlarmCompliances 1 }
|
|
|
|
END
|