- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
1663 lines
49 KiB
Text
1663 lines
49 KiB
Text
PT-RADIOLINK-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,OBJECT-TYPE,Counter32, Integer32, IpAddress FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
|
|
InetAddressIPv6 FROM INET-ADDRESS-MIB
|
|
ifEntry FROM IF-MIB
|
|
pt FROM PT-MIB;
|
|
|
|
|
|
ptRadioLink MODULE-IDENTITY
|
|
LAST-UPDATED "201712011600Z"
|
|
ORGANIZATION "Ericsson"
|
|
CONTACT-INFO
|
|
"Anders Ekvall
|
|
Postal: Ericsson AB,
|
|
E-Mail: anders.ekvall@ericsson.com"
|
|
|
|
DESCRIPTION
|
|
"This is the MIB for Radio Link specifics in PT"
|
|
|
|
REVISION "201712011600Z"
|
|
DESCRIPTION
|
|
"Added plcAdminStatus and plcOperStatus."
|
|
|
|
REVISION "201704051000Z"
|
|
DESCRIPTION
|
|
"Added channelSpacing enums."
|
|
|
|
REVISION "201701181000Z"
|
|
DESCRIPTION
|
|
"Added mlhcAdminStatus, mlhcOperStatus and mlhcMplsConfig."
|
|
|
|
REVISION "201612061400Z"
|
|
DESCRIPTION
|
|
"Added more MOs in ctTable and rltTable. Added G.826 tables."
|
|
|
|
REVISION "201605221030Z"
|
|
DESCRIPTION
|
|
"The initial version of this MIB module
|
|
with OID for MINI-LINK."
|
|
|
|
|
|
::= { pt 7 }
|
|
|
|
ptRadioLinkConformance OBJECT IDENTIFIER ::= { ptRadioLink 2 }
|
|
ctPerformance OBJECT IDENTIFIER ::= { ptRadioLink 4 }
|
|
|
|
---
|
|
--- Textual conventions
|
|
---
|
|
AcmTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer which indicates the ACM."
|
|
SYNTAX INTEGER
|
|
{
|
|
acmHalfBpsk(1),
|
|
acmHalfBpskLight(2),
|
|
acmHalfBpskStrong(3),
|
|
acmBpsk(4),
|
|
acmBpskLight(5),
|
|
acmBpskStrong(6),
|
|
acm4Qam(7),
|
|
acm4QamLight(8),
|
|
acm4QamStrong(9),
|
|
acm16Qam(10),
|
|
acm16QamLight(11),
|
|
acm16QamStrong(12),
|
|
acm32Qam(13),
|
|
acm32QamLight(14),
|
|
acm32QamStrong(15),
|
|
acm64Qam(16),
|
|
acm64QamLight(17),
|
|
acm64QamStrong(18),
|
|
acm128Qam(19),
|
|
acm128QamLight(20),
|
|
acm128QamStrong(21),
|
|
acm256Qam(22),
|
|
acm256QamLight(23),
|
|
acm256QamStrong(24),
|
|
acm512Qam(25),
|
|
acm512QamLight(26),
|
|
acm512QamStrong(27),
|
|
acm1024Qam(28),
|
|
acm1024QamLight(29),
|
|
acm1024QamStrong(30),
|
|
acm2048Qam(31),
|
|
acm2048QamLight(32),
|
|
acm2048QamStrong(33),
|
|
acm4096Qam(34),
|
|
acm4096QamLight(35),
|
|
acm4096QamStrong(36)
|
|
}
|
|
|
|
|
|
EnableStatusTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer which indicates the enabled status."
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2),
|
|
unknown(3)
|
|
}
|
|
|
|
XpicMimoTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer which indicates the XPIC or MIMO status."
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(1),
|
|
locked(2),
|
|
unlocked(3),
|
|
unknown(4)
|
|
}
|
|
|
|
---
|
|
---The definition of ctTable
|
|
---
|
|
ctTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of CT Table entries."
|
|
::= { ptRadioLink 1 }
|
|
|
|
ctEntry OBJECT-TYPE
|
|
SYNTAX CtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry of CT application."
|
|
AUGMENTS { ifEntry }
|
|
::= { ctTable 1 }
|
|
|
|
CtEntry ::=
|
|
SEQUENCE {
|
|
actualInputPower OCTET STRING,
|
|
actualOutputPower OCTET STRING,
|
|
actualRxAcm OCTET STRING,
|
|
actualTxAcm OCTET STRING,
|
|
ctDistinguishedName OCTET STRING,
|
|
description OCTET STRING,
|
|
carrierId INTEGER,
|
|
ctStatus INTEGER,
|
|
frameId Integer32,
|
|
txFrequency Integer32,
|
|
minTxFrequency Integer32,
|
|
maxTxFrequency Integer32,
|
|
rxFrequency Integer32,
|
|
minRxFrequency Integer32,
|
|
maxRxFrequency Integer32,
|
|
frequencyStepSize Integer32,
|
|
duplexDistance Integer32,
|
|
duplexType INTEGER,
|
|
duplexConfig EnableStatusTC,
|
|
autoFreqSelection INTEGER,
|
|
autoFreqSelectedChannel Integer32,
|
|
autoFreqSelectionStatus INTEGER,
|
|
channelSpacing INTEGER,
|
|
polarization INTEGER,
|
|
txOperStatus INTEGER,
|
|
txAdminStatus INTEGER,
|
|
selectedOutputPowerType INTEGER,
|
|
availableOutputPowerType INTEGER,
|
|
selectedMinOutputPower Integer32,
|
|
selectedMaxOutputPower Integer32,
|
|
availableMinOutputPower Integer32,
|
|
availableMaxOutputPower Integer32,
|
|
referenceSec INTEGER,
|
|
targetInputPowerFarEnd Integer32,
|
|
berAlarmThreshold INTEGER,
|
|
inputPowerAlarmThreshold Integer32,
|
|
plannedAlignmentInputPower Integer32,
|
|
atpcFallback EnableStatusTC,
|
|
atpcFallbackTimer Integer32,
|
|
atpcFallbackOutputPower Integer32,
|
|
xpicStatus XpicMimoTC,
|
|
mimoStatus XpicMimoTC,
|
|
actualSnir OCTET STRING,
|
|
actualXpi OCTET STRING,
|
|
actualSi OCTET STRING,
|
|
actualTxCapacity Integer32,
|
|
licensedCapacity Integer32,
|
|
availableMinCapacity Integer32,
|
|
availableMaxCapacity Integer32,
|
|
selectedMinCapacity Integer32,
|
|
selectedMaxCapacity Integer32,
|
|
wantedLicensedCapacity Integer32,
|
|
availableMinAcm AcmTC,
|
|
availableMaxAcm AcmTC,
|
|
selectedMinAcm AcmTC,
|
|
selectedMaxAcm AcmTC,
|
|
actualRxAcmTC AcmTC,
|
|
actualTxAcmTC AcmTC,
|
|
alignmentMode EnableStatusTC,
|
|
rfLoop EnableStatusTC
|
|
}
|
|
|
|
actualInputPower OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual input power of the CT in dBm"
|
|
::= { ctEntry 1 }
|
|
|
|
actualOutputPower OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual output power of the CT in dBm"
|
|
::= { ctEntry 2 }
|
|
|
|
actualRxAcm OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual rx modulation and coding"
|
|
::= { ctEntry 3 }
|
|
|
|
actualTxAcm OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual tx modulation and coding"
|
|
::= { ctEntry 4 }
|
|
|
|
ctDistinguishedName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique id/name of the carrier termination, according to FDN (rack/slot/port/class)"
|
|
::= { ctEntry 5 }
|
|
|
|
description OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User description of the carrior termination."
|
|
::= { ctEntry 6 }
|
|
|
|
carrierId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
a(1),
|
|
b(2),
|
|
c(3),
|
|
d(4),
|
|
unknown(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of the carrier. (A, B, C, D)
|
|
Used in XPIC & MIMO configurations to check that the carrier termination is connected to the correct far end carrier termination.
|
|
Should be the same id on both sides of the hop. Defaulted when not MIMO or XPIC.
|
|
Sometimes also referred to as preamble"
|
|
::= { ctEntry 7 }
|
|
|
|
ctStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
down(1),
|
|
up(2),
|
|
na(3),
|
|
unknown(4),
|
|
degraded(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the carrier termination, hop"
|
|
::= { ctEntry 8}
|
|
|
|
frameId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for the radio frame to be used.
|
|
Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
|
|
::= { ctEntry 9}
|
|
|
|
txFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selected frequency on the transmitter (kHz).
|
|
Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
|
|
::= { ctEntry 10}
|
|
|
|
minTxFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum Tx frequency possible to use, given by the selected frame-id"
|
|
::= { ctEntry 11}
|
|
|
|
maxTxFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum Tx frequency possible to use, given by the selected frame-id"
|
|
::= { ctEntry 12}
|
|
|
|
rxFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selected frequency on the receiver (kHz).
|
|
Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
|
|
::= { ctEntry 13}
|
|
|
|
minRxFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum Rx frequency possible to use, given by the selected frame-id"
|
|
::= { ctEntry 14}
|
|
|
|
maxRxFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum Rx frequency possible to use, given by the selected frame-id"
|
|
::= { ctEntry 15}
|
|
|
|
frequencyStepSize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frequency step size in kHz"
|
|
::= { ctEntry 16}
|
|
|
|
duplexDistance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Distance between Tx and Rx frequencies (kHz)"
|
|
::= { ctEntry 17}
|
|
|
|
duplexType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
variable(1),
|
|
fixed(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The duplex type is given by the equipment (Fixed,Variable)"
|
|
::= { ctEntry 18}
|
|
|
|
|
|
duplexConfig OBJECT-TYPE
|
|
SYNTAX EnableStatusTC
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling or disabling configuration of Rx freq using duplex distance"
|
|
::= { ctEntry 19}
|
|
|
|
autoFreqSelection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(1),
|
|
master(2),
|
|
slave(3),
|
|
unknown(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic frequency selection mode"
|
|
::= { ctEntry 20}
|
|
|
|
autoFreqSelectedChannel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic frequency selected channel"
|
|
::= { ctEntry 21}
|
|
|
|
autoFreqSelectionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
idle(1),
|
|
searchingForSlave(2),
|
|
requestingInfoFromSlave(3),
|
|
waitingForMaster(4),
|
|
waitingForChannelInfoRequest(5),
|
|
inProgress(6),
|
|
initializing(7),
|
|
finished(8),
|
|
failed(9),
|
|
unknown(10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic frequency status"
|
|
::= { ctEntry 22}
|
|
|
|
channelSpacing OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
cs7MHz(1),
|
|
cs10MHz(2),
|
|
cs14MHz(3),
|
|
cs20MHz(4),
|
|
cs28MHz(5),
|
|
cs30MHz(6),
|
|
cs40MHz(7),
|
|
cs50MHz(8),
|
|
cs56MHz(9),
|
|
cs250MHz(10),
|
|
cs60MHz(11),
|
|
cs500MHz(12),
|
|
cs750MHz(13),
|
|
cs100MHz(14),
|
|
cs150MHz(15),
|
|
cs200MHz(16),
|
|
cs125MHz(17),
|
|
cs80MHz(18),
|
|
cs112MHz(19),
|
|
cs1000MHz(20),
|
|
cs1250MHz(21),
|
|
cs1500MHz(22),
|
|
cs62p5MHz(23),
|
|
cs2000MHz(24),
|
|
unknown(25)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Channel spacing"
|
|
::= { ctEntry 23}
|
|
|
|
polarization OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSpecified(1),
|
|
horizontal(2),
|
|
vertical(3),
|
|
unknown(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Antenna polarization"
|
|
::= { ctEntry 24}
|
|
|
|
txOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
off(2),
|
|
on(3),
|
|
standby(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operative status of the transmitter"
|
|
::= { ctEntry 25}
|
|
|
|
txAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(1),
|
|
on(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrative status of the transmitter"
|
|
::= { ctEntry 26}
|
|
|
|
selectedOutputPowerType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
standard(1),
|
|
high(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selected output power type"
|
|
::= { ctEntry 27}
|
|
|
|
availableOutputPowerType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
standard(1),
|
|
high(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Available output power type"
|
|
::= { ctEntry 28}
|
|
|
|
selectedMinOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selected min output power.
|
|
Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode."
|
|
::= { ctEntry 29}
|
|
|
|
selectedMaxOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selected max output power.
|
|
Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode."
|
|
::= { ctEntry 30}
|
|
|
|
|
|
availableMinOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum output power supported (dBm).
|
|
The system shows a value if the equipment is available and a frame id has been selected."
|
|
::= { ctEntry 31}
|
|
|
|
availableMaxOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum output power supported (dBm).
|
|
The system shows a value if the equipment is available and a frame id has been selected."
|
|
::= { ctEntry 32}
|
|
|
|
referenceSec OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noAvailable(1),
|
|
sec2(2),
|
|
sec4L(4),
|
|
sec4H(5),
|
|
sec5B(7),
|
|
sec6B(9),
|
|
sec5LB(10),
|
|
sec5HB(11),
|
|
sec6LB(12),
|
|
sec6HB(13),
|
|
sec7B(14),
|
|
unknown(15)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each modulation is compliant to a Reference Spectrum Efficiency Class (RSEC).
|
|
When running Adaptive Coding/Modulation, one SEC has to be selected for all the coding/modulations between selectedMinACM and selectedMaxACM.
|
|
This parameter is called Reference SEC. This setting will affect availableMaxOutputPower, in order to fulfill spectrum requirements.
|
|
Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination."
|
|
::= { ctEntry 33}
|
|
|
|
targetInputPowerFarEnd OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The wanted input power at far end (dBm), when running ATPC"
|
|
::= { ctEntry 34}
|
|
|
|
berAlarmThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
tenExpMinus6(1),
|
|
tenExpMinus3(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Threshold for the BER alarm"
|
|
::= { ctEntry 35}
|
|
|
|
inputPowerAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Threshold for the input power alarm"
|
|
::= { ctEntry 36}
|
|
|
|
plannedAlignmentInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The planned received input power (dBm) dependent upon selected minimum ACM and corresponding output power.
|
|
Used when doing alignment"
|
|
::= { ctEntry 37}
|
|
|
|
atpcFallback OBJECT-TYPE
|
|
SYNTAX EnableStatusTC
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable or disable the output power fall back function"
|
|
::= { ctEntry 38}
|
|
|
|
atpcFallbackTimer OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the timer for output power fall back (# of seconds)"
|
|
::= { ctEntry 39}
|
|
|
|
atpcFallbackOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATPC fallback output power"
|
|
::= { ctEntry 40}
|
|
|
|
xpicStatus OBJECT-TYPE
|
|
SYNTAX XpicMimoTC
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the XPIC function."
|
|
::= { ctEntry 41}
|
|
|
|
mimoStatus OBJECT-TYPE
|
|
SYNTAX XpicMimoTC
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the MIMO function."
|
|
::= { ctEntry 42}
|
|
|
|
actualSnir OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual signal to noise plus interference ratio (dB)."
|
|
::= { ctEntry 43}
|
|
|
|
actualXpi OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The carrier to cross-polar interference level (dBc)."
|
|
::= { ctEntry 44}
|
|
|
|
actualSi OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Spatial interference between the CTs when MIMO is configured."
|
|
::= { ctEntry 45}
|
|
|
|
actualTxCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual capacity supported by the carrier termination."
|
|
::= { ctEntry 46}
|
|
|
|
licensedCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wanted or installed license for the capacity allowed for the carrier termination."
|
|
::= { ctEntry 47}
|
|
|
|
availableMinCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum capacity possible to use. Given by the selected frame-id (kbit/s)"
|
|
::= { ctEntry 48}
|
|
|
|
availableMaxCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum capacity possible to use. Given by the selected frame-id (kbit/s)"
|
|
::= { ctEntry 49}
|
|
|
|
selectedMinCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selected minimum capacity, derived from selected minimum ACM (kbit/s)"
|
|
::= { ctEntry 50}
|
|
|
|
selectedMaxCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selected maximum capacity, derived from selected maximum ACM (kbit/s)"
|
|
::= { ctEntry 51}
|
|
|
|
wantedLicensedCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wanted licensed capacity and creation of LRF for the carrier termination (kbit/s)"
|
|
::= { ctEntry 52}
|
|
|
|
availableMinAcm OBJECT-TYPE
|
|
SYNTAX AcmTC
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum ACM possible to use, given by the selected frame id."
|
|
::= { ctEntry 53}
|
|
|
|
availableMaxAcm OBJECT-TYPE
|
|
SYNTAX AcmTC
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum ACM possible to use, given by the selected frame id"
|
|
::= { ctEntry 54}
|
|
|
|
selectedMinAcm OBJECT-TYPE
|
|
SYNTAX AcmTC
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selected minimum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed"
|
|
::= { ctEntry 55}
|
|
|
|
selectedMaxAcm OBJECT-TYPE
|
|
SYNTAX AcmTC
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selected maximum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed"
|
|
::= { ctEntry 56}
|
|
|
|
actualRxAcmTC OBJECT-TYPE
|
|
SYNTAX AcmTC
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual rx modulation and coding"
|
|
::= { ctEntry 57}
|
|
|
|
actualTxAcmTC OBJECT-TYPE
|
|
SYNTAX AcmTC
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual tx modulation and coding"
|
|
::= { ctEntry 58}
|
|
|
|
alignmentMode OBJECT-TYPE
|
|
SYNTAX EnableStatusTC
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable or disable the alignment mode"
|
|
::= { ctEntry 59}
|
|
|
|
rfLoop OBJECT-TYPE
|
|
SYNTAX EnableStatusTC
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable or disable the rf loop"
|
|
::= { ctEntry 60}
|
|
|
|
|
|
---
|
|
---The definition of rltTable
|
|
---
|
|
rltTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of RLT Table entries."
|
|
::= { ptRadioLink 3 }
|
|
|
|
rltEntry OBJECT-TYPE
|
|
SYNTAX RltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry of RLT application."
|
|
AUGMENTS { ifEntry }
|
|
::= { rltTable 1 }
|
|
|
|
RltEntry ::=
|
|
SEQUENCE {
|
|
rltDistinguishedName OCTET STRING,
|
|
neIpAddress IpAddress,
|
|
neIpv6Address InetAddressIPv6,
|
|
neName OCTET STRING,
|
|
neType INTEGER,
|
|
id OCTET STRING,
|
|
rltStatus INTEGER,
|
|
mode INTEGER,
|
|
actualTxTotalCapacity Integer32,
|
|
limitedTotalCapacity Integer32,
|
|
protectionStatus INTEGER,
|
|
revertiveWaitToRestore Integer32,
|
|
revertivePreferredTx INTEGER,
|
|
protectionSwitchMode INTEGER,
|
|
fadeNotificationTimer Integer32,
|
|
expectedFarEndId OCTET STRING,
|
|
farEndIdCheck INTEGER,
|
|
cpriMode INTEGER,
|
|
cpriStatus INTEGER,
|
|
manualSwitch INTEGER,
|
|
mlhcOperStatus INTEGER,
|
|
mlhcAdminStatus INTEGER,
|
|
mlhcMplsConfig INTEGER,
|
|
plcOperStatus INTEGER,
|
|
plcAdminStatus INTEGER
|
|
}
|
|
|
|
rltDistinguishedName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique id/name of the radio link termination, according to FDN (rack/slot/port/class)"
|
|
::= { rltEntry 1 }
|
|
|
|
neIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NE IP address"
|
|
::= { rltEntry 2 }
|
|
|
|
neIpv6Address OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NE IP V6 address"
|
|
::= { rltEntry 3 }
|
|
|
|
neName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NE Name"
|
|
::= { rltEntry 4 }
|
|
|
|
neType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
mle(2),
|
|
xfMle(3),
|
|
tn(4),
|
|
cn(5),
|
|
pt(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NE Type"
|
|
::= { rltEntry 5 }
|
|
|
|
id OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User defined id of the radio link terminal"
|
|
::= { rltEntry 6}
|
|
|
|
rltStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
down(1),
|
|
up(2),
|
|
na(3),
|
|
unknown(4),
|
|
degraded(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the radio link terminal"
|
|
::= { rltEntry 7}
|
|
|
|
mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
mode1plus0(1),
|
|
mode1plus1CSB(2),
|
|
mode1plus1RLP(3),
|
|
mode2plus0RLB(4),
|
|
mode2plus1CSB(5),
|
|
mode2plus1RLP(6),
|
|
mode2plus2CSB(7),
|
|
mode2plus2RLP(8),
|
|
mode3plus0RLB(9),
|
|
mode4plus0RLB(10),
|
|
notAvailable11(11),
|
|
notAvailable12(12),
|
|
notAvailable13(13),
|
|
notAvailable14(14),
|
|
mode3plus1RLP(15),
|
|
mode3plus2RLP(16),
|
|
mode3plus3RLP(17),
|
|
mode4plus1RLP(18),
|
|
mode4plus2RLP(19),
|
|
mode4plus3RLP(20),
|
|
mode4plus4RLP(21),
|
|
notAvailable22(22),
|
|
notAvailable23(23),
|
|
notAvailable24(24),
|
|
notAvailable25(25),
|
|
notAvailable26(26),
|
|
notAvailable27(27),
|
|
mode3plus1CSB(28),
|
|
mode3plus2CSB(29),
|
|
mode3plus3CSB(30),
|
|
mode4plus1CSB(31),
|
|
mode4plus2CSB(32),
|
|
mode4plus3CSB(33),
|
|
mode4plus4CSB(34),
|
|
unknown(35)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the radio link terminal"
|
|
::= { rltEntry 8}
|
|
|
|
actualTxTotalCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual aggregated total (packet + TDM) transmitter capacity for the radio link termination.
|
|
Limited by licenses & configuration (=nearEndLimitedCapacity) and depending on actual modulation/coding used at the moment."
|
|
::= { rltEntry 9 }
|
|
|
|
limitedTotalCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum total capacity allowed by the current configuration and installed licenses.
|
|
Aggregated from the constituent carrier termination values."
|
|
::= { rltEntry 10 }
|
|
|
|
|
|
protectionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unprotected(1),
|
|
protected(2),
|
|
unableToProtect(3),
|
|
unknown(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of a protected node."
|
|
::= { rltEntry 11}
|
|
|
|
revertiveWaitToRestore OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time, in number of seconds, to wait before switching back to the preferred Tx."
|
|
::= { rltEntry 12}
|
|
|
|
revertivePreferredTx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ct11(1),
|
|
ct12(2),
|
|
ct21(3),
|
|
ct22(4),
|
|
notApplicable(5),
|
|
unknown(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The preferred carrier termination transmitter."
|
|
::= { rltEntry 13}
|
|
|
|
|
|
|
|
protectionSwitchMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
auto(1),
|
|
manual(2),
|
|
autoAndRevertive(3),
|
|
unknown(4),
|
|
notApplicable(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
".The mode in which the switching mechanism is configured"
|
|
::= { rltEntry 14}
|
|
|
|
|
|
fadeNotificationTimer OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification is sent if fading is longer than this timer, applicable for protection."
|
|
::= { rltEntry 15}
|
|
|
|
expectedFarEndId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Expected id of far-end terminal"
|
|
::= { rltEntry 16 }
|
|
|
|
farEndIdCheck OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling of far end id check."
|
|
::= { rltEntry 17}
|
|
|
|
cpriMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
master(1),
|
|
slave(2),
|
|
notApplicable(3),
|
|
unknown(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set the mode of the CPRI front-haul product."
|
|
::= { rltEntry 18}
|
|
|
|
cpriStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
idle(1),
|
|
waitingOnRtcSync(2),
|
|
waitingOnCpri(3),
|
|
waitingOnRxRequest(4),
|
|
waitingOnTxRequest(5),
|
|
inSync(6),
|
|
unknown(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the CPRI front-haul product."
|
|
::= { rltEntry 19}
|
|
|
|
manualSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ct11(1),
|
|
ct12(2),
|
|
ct21(3),
|
|
ct22(4),
|
|
notApplicable(5),
|
|
unknown(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual switch of protected carrier termination transmitter."
|
|
::= { rltEntry 20}
|
|
|
|
mlhcOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operative status of multi layer header compression."
|
|
::= { rltEntry 21}
|
|
|
|
mlhcAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(1),
|
|
on(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrative status of multi layer header compression."
|
|
::= { rltEntry 22}
|
|
|
|
mlhcMplsConfig OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
controlWord(1),
|
|
l2(2),
|
|
l3(3),
|
|
mplsOnly(4),
|
|
unknown(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MLHC/MPLS configuration."
|
|
::= { rltEntry 23}
|
|
|
|
plcOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operative status of payload compression."
|
|
::= { rltEntry 24}
|
|
|
|
plcAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(1),
|
|
on(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrative status of payload compression."
|
|
::= { rltEntry 25}
|
|
---
|
|
---The definition of ct826ContinuousTable
|
|
---
|
|
ctG826ContinuousTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtG826ContinuousEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of CT G826 Performance Continuous counters entries.
|
|
The counters are reset by ctG826Reset"
|
|
::= { ctPerformance 1 }
|
|
|
|
ctG826ContinuousEntry OBJECT-TYPE
|
|
SYNTAX CtG826ContinuousEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry of CT G826 Performance Continuous counters."
|
|
AUGMENTS { ifEntry }
|
|
::= { ctG826ContinuousTable 1 }
|
|
|
|
CtG826ContinuousEntry ::=
|
|
SEQUENCE {
|
|
ctG826TimeElapsed Counter32,
|
|
ctBBE Counter32,
|
|
ctBBER OCTET STRING,
|
|
ctES Counter32,
|
|
ctESR OCTET STRING,
|
|
ctSES Counter32,
|
|
ctSESR OCTET STRING,
|
|
ctBB OCTET STRING,
|
|
ctUAS Counter32,
|
|
ctG826Reset INTEGER
|
|
}
|
|
|
|
ctG826TimeElapsed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time elapsed in seconds since last PMReset"
|
|
::= { ctG826ContinuousEntry 1 }
|
|
|
|
ctBBE OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Background Block Errors"
|
|
::= { ctG826ContinuousEntry 2 }
|
|
|
|
ctBBER OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Background Block Errors Ratio"
|
|
::= { ctG826ContinuousEntry 3 }
|
|
|
|
ctES OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error seconds"
|
|
::= { ctG826ContinuousEntry 4 }
|
|
|
|
ctESR OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error seconds Ratio"
|
|
::= { ctG826ContinuousEntry 5 }
|
|
|
|
ctSES OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severely error seconds"
|
|
::= { ctG826ContinuousEntry 6 }
|
|
|
|
ctSESR OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severely error seconds Ratio"
|
|
::= { ctG826ContinuousEntry 7 }
|
|
|
|
ctBB OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Background blocks"
|
|
::= { ctG826ContinuousEntry 8 }
|
|
|
|
ctUAS OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unavailable seconds "
|
|
::= { ctG826ContinuousEntry 9 }
|
|
|
|
ctG826Reset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
noReset(2),
|
|
reset(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset the continuous PM counters"
|
|
::= { ctG826ContinuousEntry 10 }
|
|
|
|
|
|
---
|
|
---The definition of ctG826Current15mTable
|
|
---
|
|
ctG826Current15mTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtG826Current15mEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of CT Performance G826 15 m current counters Table entries."
|
|
::= { ctPerformance 2 }
|
|
|
|
ctG826Current15mEntry OBJECT-TYPE
|
|
SYNTAX CtG826Current15mEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry of CT Performance G826 15 m current Table counters."
|
|
AUGMENTS { ifEntry }
|
|
::= { ctG826Current15mTable 1 }
|
|
|
|
CtG826Current15mEntry ::=
|
|
SEQUENCE {
|
|
ctG826Current15mTimeElapsed Counter32,
|
|
ctCurrent15mBBE Counter32,
|
|
ctCurrent15mBBER OCTET STRING,
|
|
ctCurrent15mES Counter32,
|
|
ctCurrent15mESR OCTET STRING,
|
|
ctCurrent15mSES Counter32,
|
|
ctCurrent15mSESR OCTET STRING,
|
|
ctCurrent15mBB Counter32,
|
|
ctCurrent15mUAS Counter32
|
|
}
|
|
|
|
ctG826Current15mTimeElapsed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time elapsed in seconds since last PMReset"
|
|
::= { ctG826Current15mEntry 1 }
|
|
|
|
ctCurrent15mBBE OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Background Block Errors"
|
|
::= { ctG826Current15mEntry 2 }
|
|
|
|
ctCurrent15mBBER OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Background Block Errors Ratio"
|
|
::= { ctG826Current15mEntry 3 }
|
|
|
|
ctCurrent15mES OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error seconds"
|
|
::= { ctG826Current15mEntry 4 }
|
|
|
|
ctCurrent15mESR OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error seconds Ratio"
|
|
::= { ctG826Current15mEntry 5 }
|
|
|
|
ctCurrent15mSES OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severely error seconds"
|
|
::= { ctG826Current15mEntry 6 }
|
|
|
|
ctCurrent15mSESR OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severely error seconds Ratio"
|
|
::= { ctG826Current15mEntry 7 }
|
|
|
|
ctCurrent15mBB OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Background blocks"
|
|
::= { ctG826Current15mEntry 8 }
|
|
|
|
ctCurrent15mUAS OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unavailable seconds "
|
|
::= { ctG826Current15mEntry 9 }
|
|
|
|
---
|
|
---The definition of ctG826Current24hTable
|
|
---
|
|
ctG826Current24hTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtG826Current24hEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of CT Performance G826 Current 24h counters entries."
|
|
::= { ctPerformance 3 }
|
|
|
|
ctG826Current24hEntry OBJECT-TYPE
|
|
SYNTAX CtG826Current24hEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry of CT Performance G826 Current 24 h counters."
|
|
AUGMENTS { ifEntry }
|
|
::= { ctG826Current24hTable 1 }
|
|
|
|
CtG826Current24hEntry ::=
|
|
SEQUENCE {
|
|
ctG826Current24hTimeElapsed Counter32,
|
|
ctCurrent24hBBE Counter32,
|
|
ctCurrent24hBBER OCTET STRING,
|
|
ctCurrent24hES Counter32,
|
|
ctCurrent24hESR OCTET STRING,
|
|
ctCurrent24hSES Counter32,
|
|
ctCurrent24hSESR OCTET STRING,
|
|
ctCurrent24hBB Counter32,
|
|
ctCurrent24hUAS Counter32
|
|
}
|
|
|
|
ctG826Current24hTimeElapsed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time elapsed in seconds since last PMReset"
|
|
::= { ctG826Current24hEntry 1 }
|
|
|
|
ctCurrent24hBBE OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Background Block Errors"
|
|
::= { ctG826Current24hEntry 2 }
|
|
|
|
ctCurrent24hBBER OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Background Block Errors Ratio"
|
|
::= { ctG826Current24hEntry 3 }
|
|
|
|
ctCurrent24hES OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error seconds"
|
|
::= { ctG826Current24hEntry 4 }
|
|
|
|
ctCurrent24hESR OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error seconds Ratio"
|
|
::= { ctG826Current24hEntry 5 }
|
|
|
|
ctCurrent24hSES OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severely error seconds"
|
|
::= { ctG826Current24hEntry 6 }
|
|
|
|
ctCurrent24hSESR OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severely error seconds Ratio"
|
|
::= { ctG826Current24hEntry 7 }
|
|
|
|
ctCurrent24hBB OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Background blocks"
|
|
::= { ctG826Current24hEntry 8 }
|
|
|
|
ctCurrent24hUAS OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unavailable seconds "
|
|
::= { ctG826Current24hEntry 9 }
|
|
|
|
--
|
|
-- Conformance
|
|
--
|
|
|
|
ptRadioLinkCompliances OBJECT IDENTIFIER ::= { ptRadioLinkConformance 1 }
|
|
ptRadioLinkGroups OBJECT IDENTIFIER ::= { ptRadioLinkConformance 2 }
|
|
|
|
ptRadioLinkFullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for SNMP entities which implement everything."
|
|
MODULE -- This Module
|
|
MANDATORY-GROUPS { ptRadioLinkCompleteGroup}
|
|
::= { ptRadioLinkCompliances 1 }
|
|
|
|
ptRadioLinkCompleteGroup OBJECT-GROUP
|
|
OBJECTS
|
|
{
|
|
actualInputPower,
|
|
actualOutputPower,
|
|
actualRxAcm,
|
|
actualRxAcmTC,
|
|
actualSi,
|
|
actualSnir,
|
|
actualTxAcm,
|
|
actualTxAcmTC,
|
|
actualTxCapacity,
|
|
actualTxTotalCapacity,
|
|
actualXpi,
|
|
alignmentMode,
|
|
atpcFallback,
|
|
atpcFallbackTimer,
|
|
atpcFallbackOutputPower,
|
|
autoFreqSelectedChannel,
|
|
autoFreqSelection,
|
|
autoFreqSelectionStatus,
|
|
availableMaxAcm,
|
|
availableMaxCapacity,
|
|
availableMaxOutputPower,
|
|
availableMinAcm,
|
|
availableMinCapacity,
|
|
availableMinOutputPower,
|
|
availableOutputPowerType,
|
|
berAlarmThreshold,
|
|
carrierId,
|
|
channelSpacing,
|
|
cpriMode,
|
|
cpriStatus,
|
|
ctDistinguishedName,
|
|
ctCurrent15mBB,
|
|
ctCurrent15mBBE,
|
|
ctCurrent15mBBER,
|
|
ctCurrent15mES,
|
|
ctCurrent15mESR,
|
|
ctCurrent15mSES,
|
|
ctCurrent15mSESR,
|
|
ctCurrent15mUAS,
|
|
ctG826Current15mTimeElapsed,
|
|
ctCurrent24hBB,
|
|
ctCurrent24hBBE,
|
|
ctCurrent24hBBER,
|
|
ctCurrent24hES,
|
|
ctCurrent24hESR,
|
|
ctCurrent24hSES,
|
|
ctCurrent24hSESR,
|
|
ctCurrent24hUAS,
|
|
ctG826Current24hTimeElapsed,
|
|
ctBB,
|
|
ctBBE,
|
|
ctBBER,
|
|
ctES,
|
|
ctESR,
|
|
ctG826Reset,
|
|
ctSES,
|
|
ctSESR,
|
|
ctG826TimeElapsed,
|
|
ctUAS,
|
|
ctStatus,
|
|
description,
|
|
duplexConfig,
|
|
duplexDistance,
|
|
duplexType,
|
|
expectedFarEndId,
|
|
fadeNotificationTimer,
|
|
farEndIdCheck,
|
|
frameId,
|
|
frequencyStepSize,
|
|
id,
|
|
inputPowerAlarmThreshold,
|
|
licensedCapacity,
|
|
limitedTotalCapacity,
|
|
manualSwitch,
|
|
maxRxFrequency,
|
|
maxTxFrequency,
|
|
mimoStatus,
|
|
minRxFrequency,
|
|
minTxFrequency,
|
|
mlhcAdminStatus,
|
|
mlhcMplsConfig,
|
|
mlhcOperStatus,
|
|
plcAdminStatus,
|
|
plcOperStatus,
|
|
mode,
|
|
neIpAddress,
|
|
neIpv6Address,
|
|
neName,
|
|
neType,
|
|
plannedAlignmentInputPower,
|
|
polarization,
|
|
protectionStatus,
|
|
protectionSwitchMode,
|
|
referenceSec,
|
|
revertivePreferredTx,
|
|
revertiveWaitToRestore,
|
|
rfLoop,
|
|
rltDistinguishedName,
|
|
rltStatus,
|
|
rxFrequency,
|
|
selectedMaxAcm,
|
|
selectedMaxCapacity,
|
|
selectedMaxOutputPower,
|
|
selectedMinAcm,
|
|
selectedMinCapacity,
|
|
selectedMinOutputPower,
|
|
selectedOutputPowerType,
|
|
targetInputPowerFarEnd,
|
|
txAdminStatus,
|
|
txFrequency,
|
|
txOperStatus,
|
|
wantedLicensedCapacity,
|
|
xpicStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of all current objects in this MIB module."
|
|
::= { ptRadioLinkGroups 1 }
|
|
|
|
|
|
END
|
|
|