- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
973 lines
No EOL
31 KiB
Text
973 lines
No EOL
31 KiB
Text
-- ***********************************************************************************************
|
|
-- TN-PTP-MIB.smi: Transition Networks Enterprise MIB for TN device SyncE feature
|
|
--
|
|
-- Copyright (c) 2013 by Transition Networks, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- ***********************************************************************************************
|
|
--
|
|
|
|
TN-PTP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
TruthValue, RowStatus
|
|
FROM SNMPv2-TC
|
|
MODULE-IDENTITY,
|
|
OBJECT-IDENTITY,
|
|
InetAddressType, InetAddress
|
|
FROM INET-ADDRESS-MIB
|
|
entPhysicalIndex FROM ENTITY-MIB
|
|
tnProducts FROM TRANSITION-SMI;
|
|
|
|
tnPtpMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201311110000Z"
|
|
ORGANIZATION "Transition Networks, Inc."
|
|
CONTACT-INFO
|
|
" Transition Networks
|
|
Technical Support
|
|
10900 Red Circle Drive
|
|
Minnetonka, MN 55343 USA
|
|
Tel: +1-800-526-9267
|
|
|
|
E-mail: techsupport@transition.com"
|
|
|
|
DESCRIPTION
|
|
"The mib provides functionalities for managing PTP."
|
|
|
|
REVISION "201311110000Z"
|
|
DESCRIPTION
|
|
"Initial Revision of this module"
|
|
::= { tnProducts 123 }
|
|
|
|
tnPtp OBJECT IDENTIFIER ::= { tnPtpMIB 1 }
|
|
--
|
|
-- PTP Clock Modes
|
|
--
|
|
tnPtpClkModesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnPtpClkModesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of SyncE External I/O"
|
|
::= { tnPtp 1 }
|
|
|
|
tnPtpClkModesEntry OBJECT-TYPE
|
|
SYNTAX TnPtpClkModesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table,tnPtpClkModesTable"
|
|
INDEX { entPhysicalIndex }
|
|
::= { tnPtpClkModesTable 1 }
|
|
|
|
TnPtpClkModesEntry ::= SEQUENCE
|
|
{
|
|
tnPtpInState INTEGER,
|
|
tnPtpOutState INTEGER,
|
|
tnPtpInFreq INTEGER,
|
|
tnPtpOutFreq INTEGER,
|
|
tnPtpImpedance INTEGER,
|
|
tnPtpActualInFreq INTEGER,
|
|
tnPtpActualOutFreq INTEGER
|
|
}
|
|
|
|
tnPtpInState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "IEEE 1588 Input State."
|
|
::= { tnPtpClkModesEntry 1 }
|
|
|
|
tnPtpOutState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "IEEE 1588 Output State."
|
|
::= { tnPtpClkModesEntry 2 }
|
|
|
|
tnPtpInFreq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
onePps(0),
|
|
f8kHz(1),
|
|
f64kHz(2),
|
|
f1544kHz(3),
|
|
f2048kHz(4),
|
|
f10000kHz(5),
|
|
f19440kHz(6),
|
|
f25Mhz(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Clock frequency 1 PPS or
|
|
8k-25Mhz table of values."
|
|
::= { tnPtpClkModesEntry 3 }
|
|
|
|
tnPtpOutFreq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The following values are possible:
|
|
Editable value with the possible range of values are 1 - 25000000 (1 - 25MHz)."
|
|
::= { tnPtpClkModesEntry 4 }
|
|
|
|
tnPtpImpedance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
imp50(1),
|
|
imp75(2),
|
|
hi-Z(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Select the impedance termination of the input clock.
|
|
The following values are possible:
|
|
1. 50 : 50 ohm impedance.
|
|
2. 75 : 75 ohm impedance.
|
|
3. Hi-Z : no impedance termination driven, tri-stated or floating."
|
|
::= { tnPtpClkModesEntry 5 }
|
|
|
|
tnPtpActualInFreq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The actual input frequency in Hz."
|
|
::= { tnPtpClkModesEntry 6 }
|
|
|
|
tnPtpActualOutFreq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The actual output frequency in Hz. If output state is disabled set to 0"
|
|
::= { tnPtpClkModesEntry 7 }
|
|
|
|
--
|
|
-- PTP Add New Clk Configuration
|
|
--
|
|
tnPtpCreateClkConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnPtpCreateClkConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of PTP ClkInstance"
|
|
::= { tnPtp 2 }
|
|
|
|
tnPtpCreateClkConfEntry OBJECT-TYPE
|
|
SYNTAX TnPtpCreateClkConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table,tnPtpCreateClkConfTable"
|
|
INDEX { tnPtpCreateClkConfIndex }
|
|
::= { tnPtpCreateClkConfTable 1 }
|
|
|
|
|
|
TnPtpCreateClkConfEntry ::= SEQUENCE
|
|
{
|
|
tnPtpCreateClkConfIndex INTEGER,
|
|
tnPtpDeviceType INTEGER,
|
|
tnPtpTwoStepFlag TruthValue,
|
|
tnPtpClockId OCTET STRING,
|
|
tnPtpOneWay TruthValue,
|
|
tnPtpProtocol INTEGER,
|
|
tnPtpVLANTag TruthValue,
|
|
tnPtpVID INTEGER,
|
|
tnPtpPCP INTEGER,
|
|
tnPtpClkConfRowStatus RowStatus
|
|
}
|
|
|
|
tnPtpCreateClkConfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Index of ptp clocks."
|
|
::= { tnPtpCreateClkConfEntry 1 }
|
|
|
|
tnPtpDeviceType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inactive(0),
|
|
ordBound(1),
|
|
p2pTransp(2),
|
|
e2eTransp(3),
|
|
masterOnly(4),
|
|
slaveOnly(5)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Indicates the Type of the Clock Instance. There are five Device Types.
|
|
1. Ord-Bound - clock's Device Type is Ordinary-Boundary Clock.
|
|
2. P2p Transp - clock's Device Type is Peer to Peer Transparent Clock.
|
|
3. E2e Transp - clock's Device Type is End to End Transparent Clock.
|
|
4. Master Only - clock's Device Type is Master Only.
|
|
5. Slave Only - clock's Device Type is Slave Only."
|
|
::= { tnPtpCreateClkConfEntry 2 }
|
|
|
|
tnPtpTwoStepFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Static member: defined by the system, true if two-step Sync events and Pdelay_Resp events are used."
|
|
::= { tnPtpCreateClkConfEntry 3 }
|
|
|
|
tnPtpClockId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique clock identifier."
|
|
::= { tnPtpCreateClkConfEntry 4 }
|
|
|
|
tnPtpOneWay OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "If true, one-way measurements are used. This parameter applies only to a slave. In one-way mode no delay
|
|
measurements are performed, i.e. this is applicable only if frequency synchronization is needed. The master always responds to delay requests.."
|
|
::= { tnPtpCreateClkConfEntry 5 }
|
|
|
|
tnPtpProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ethernet(0),
|
|
ipv4multi(1),
|
|
ipv4uni(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Transport protocol used by the PTP protocol engine
|
|
ethernet PTP over Ethernet multicast
|
|
ip4multi PTP over IPv4 multicast
|
|
ip4uni PTP over IPv4 unicast
|
|
Note : IPv4 unicast protocol only works in Master only and Slave only clocks
|
|
See parameter Device Type
|
|
In a unicast Slave only clock you also need configure which master clocks
|
|
to request Announce and Sync messages from. See: Unicast Slave Configuration."
|
|
::= { tnPtpCreateClkConfEntry 6 }
|
|
|
|
tnPtpVLANTag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Enables the VLAN tagging for the PTP frames.
|
|
Note: Packets are only tagged if the port is configured for vlan tagging. i.e:
|
|
Port Type != Unaware and PortVLAN mode == None, and the port is member of the VLAN."
|
|
::= { tnPtpCreateClkConfEntry 7 }
|
|
|
|
tnPtpVID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "VLAN Identifier used for tagging the PTP frames."
|
|
::= { tnPtpCreateClkConfEntry 8 }
|
|
|
|
tnPtpPCP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Priority Code Point value used for PTP frames."
|
|
::= { tnPtpCreateClkConfEntry 9 }
|
|
|
|
tnPtpClkConfRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the row.
|
|
|
|
The writable columns in a row cannot be changed if the row
|
|
is active. All columns must have a valid value before a row
|
|
can be activated."
|
|
::= { tnPtpCreateClkConfEntry 10 }
|
|
|
|
--
|
|
-- PTP Clk Configuration 0
|
|
--
|
|
tnPtpClkConf0Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnPtpClkConf0Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of PTP ClkInstance"
|
|
::= { tnPtp 3 }
|
|
|
|
tnPtpClkConf0Entry OBJECT-TYPE
|
|
SYNTAX TnPtpClkConf0Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table,tnPtpClkConf0Table"
|
|
INDEX { tnPtpClkConf0Index }
|
|
::= { tnPtpClkConf0Table 1 }
|
|
|
|
|
|
TnPtpClkConf0Entry ::= SEQUENCE
|
|
{
|
|
tnPtpClkConf0Index INTEGER,
|
|
|
|
tnPtpDefaultDom INTEGER,
|
|
tnPtpDefaultClockQuality OCTET STRING,
|
|
tnPtpDefaultPri1 INTEGER,
|
|
tnPtpDefaultPri2 INTEGER,
|
|
|
|
tnPtpTime OCTET STRING,
|
|
tnPtpAdjustMethod INTEGER,
|
|
tnPtpSynce INTEGER,
|
|
}
|
|
|
|
tnPtpClkConf0Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..CLOCK_INST_MAX]."
|
|
::= { tnPtpClkConf0Entry 1 }
|
|
|
|
tnPtpDefaultDom OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Clock domain [0..127]."
|
|
::= { tnPtpClkConf0Entry 2 }
|
|
|
|
tnPtpDefaultClockQuality OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clock quality is determined by the system, and holds 3 parts: Clock Class, Clock Accuracy and OffsetScaledLog Variance as defined in IEEE1588.
|
|
The Clock Accuracy values are defined in IEEE1588 table 6 (Currently the clock Accuracy is set to 'Unknown' as default)."
|
|
::= { tnPtpClkConf0Entry 3 }
|
|
|
|
tnPtpDefaultPri1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Clock priority 1 [0..255] used by the BMC master select algorithm."
|
|
::= { tnPtpClkConf0Entry 4 }
|
|
|
|
tnPtpDefaultPri2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Clock priority 2 [0..255] used by the BMC master select algorithm."
|
|
::= { tnPtpClkConf0Entry 5 }
|
|
|
|
tnPtpTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the actual PTP time with nanosecond resolution."
|
|
::= { tnPtpClkConf0Entry 6 }
|
|
|
|
tnPtpAdjustMethod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
internal(1),
|
|
vcxo(2),
|
|
software(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Shows the actual clock adjustment method. The method depends on the available hardware."
|
|
::= { tnPtpClkConf0Entry 7 }
|
|
|
|
tnPtpSynce OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
doNothing(1),
|
|
sync(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Activate to synchronize the System Clock to PTP Time."
|
|
::= { tnPtpClkConf0Entry 8 }
|
|
|
|
--
|
|
-- PTP Clk Configuration 1
|
|
--
|
|
tnPtpClkConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnPtpClkConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of PTP ClkInstance"
|
|
::= { tnPtp 4 }
|
|
|
|
tnPtpClkConfEntry OBJECT-TYPE
|
|
SYNTAX TnPtpClkConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table,tnPtpClkConfTable"
|
|
INDEX { tnPtpClkConfIndex }
|
|
::= { tnPtpClkConfTable 1 }
|
|
|
|
|
|
TnPtpClkConfEntry ::= SEQUENCE
|
|
{
|
|
tnPtpClkConfIndex INTEGER,
|
|
|
|
tnPtpStpRm INTEGER,
|
|
tnPtpOffset OCTET STRING,
|
|
tnPtpPathDelay OCTET STRING,
|
|
tnPtpDelayFilter INTEGER,
|
|
tnPtpFilterPeriod INTEGER,
|
|
tnPtpFilterDist INTEGER,
|
|
|
|
tnPtpParentPortId OCTET STRING,
|
|
tnPtpParentPort INTEGER,
|
|
tnPtpParentPStat TruthValue,
|
|
tnPtpParentVar INTEGER,
|
|
tnPtpParentChgRate INTEGER,
|
|
tnPtpParentGMId OCTET STRING,
|
|
tnPtpParentGMQual OCTET STRING,
|
|
tnPtpParentPri1 INTEGER,
|
|
tnPtpParentPri2 INTEGER
|
|
}
|
|
|
|
tnPtpClkConfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..CLOCK_INST_MAX]."
|
|
::= { tnPtpClkConfEntry 1 }
|
|
|
|
tnPtpStpRm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Steps Removed : It is the number of PTP clocks traversed from the grandmaster to the local slave clock."
|
|
::= { tnPtpClkConfEntry 2 }
|
|
|
|
tnPtpOffset OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time difference between the master clock and the local slave clock, measured in ns."
|
|
::= { tnPtpClkConfEntry 3 }
|
|
|
|
tnPtpPathDelay OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The mean propagation time for the link between the master and the local slave."
|
|
::= { tnPtpClkConfEntry 4 }
|
|
|
|
tnPtpDelayFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The default delay filter is a low pass filter, with a time constant of 2**DelayFilter*DelayRequestRate.
|
|
The value must be in the range of 1..6."
|
|
::= { tnPtpClkConfEntry 5 }
|
|
|
|
tnPtpFilterPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The default offset filter uses a minimum delay filter method
|
|
i.e. The minimum measured offset during Period samples is used in the calculation.
|
|
The value must be in the range of 1..1000."
|
|
::= { tnPtpClkConfEntry 6 }
|
|
|
|
tnPtpFilterDist OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The distance between two calculations is Dist periods.
|
|
Note: In configurations with Timestamp enabled PHYs, the period is automatically increased, if (period*dist < SyncPackets pr sec/4),
|
|
i.e. max 4 adjustments are made pr sec.
|
|
If Dist is 1 the offset is averaged over the Period,
|
|
If Dist is >1 the offset is calculated using 'min' offset.
|
|
The value must be in the range of 1..10"
|
|
::= { tnPtpClkConfEntry 7 }
|
|
|
|
tnPtpParentPortId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Clock identity for the parent clock, if the local clock is not a slave, the value is the clocks own id."
|
|
::= { tnPtpClkConfEntry 8 }
|
|
|
|
tnPtpParentPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port Id for the parent master port."
|
|
::= { tnPtpClkConfEntry 9 }
|
|
|
|
tnPtpParentPStat OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Parents Stats (always false)."
|
|
::= { tnPtpClkConfEntry 10 }
|
|
|
|
tnPtpParentVar OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is observed parent offset scaled log variance."
|
|
::= { tnPtpClkConfEntry 11 }
|
|
|
|
tnPtpParentChgRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Observed Parent Clock Phase Change Rate. i.e. the slave clocks rate offset compared to the master. (unit = ns per s)."
|
|
::= { tnPtpClkConfEntry 12 }
|
|
|
|
tnPtpParentGMId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Clock identity for the grand master clock, if the local clock is not a slave, the value is the clocks own id."
|
|
::= { tnPtpClkConfEntry 13 }
|
|
|
|
tnPtpParentGMQual OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The clock quality announced by the grand master."
|
|
::= { tnPtpClkConfEntry 14 }
|
|
|
|
tnPtpParentPri1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Clock priority 1 announced by the grand master."
|
|
::= { tnPtpClkConfEntry 15 }
|
|
|
|
tnPtpParentPri2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Clock priority 2 announced by the grand master."
|
|
::= { tnPtpClkConfEntry 16 }
|
|
|
|
--
|
|
-- PTP Clk Configuration 2
|
|
--
|
|
tnPtpClkConf2Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnPtpClkConf2Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table 2 of PTP ClkInstance"
|
|
::= { tnPtp 5 }
|
|
|
|
tnPtpClkConf2Entry OBJECT-TYPE
|
|
SYNTAX TnPtpClkConf2Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table,tnPtpClkConf2Table"
|
|
INDEX { tnPtpClkConfIndex2 }
|
|
::= { tnPtpClkConf2Table 1 }
|
|
|
|
|
|
TnPtpClkConf2Entry ::= SEQUENCE
|
|
{
|
|
tnPtpClkConfIndex2 INTEGER,
|
|
|
|
tnPtpUtcOffset INTEGER,
|
|
tnPtpValid TruthValue,
|
|
tnPtpLeap59 TruthValue,
|
|
tnPtpLeap61 TruthValue,
|
|
tnPtpTimeTrac TruthValue,
|
|
tnPtpFreqTrac TruthValue,
|
|
tnPtpTimeScale TruthValue,
|
|
tnPtpTimeSource INTEGER,
|
|
|
|
tnPtpDisplay TruthValue,
|
|
tnPtpPEnable TruthValue,
|
|
tnPtpIEnable TruthValue,
|
|
tnPtpDEnable TruthValue,
|
|
tnPtpPConstant INTEGER,
|
|
tnPtpIConstant INTEGER,
|
|
tnPtpDConstant INTEGER,
|
|
tnPtpServoDelayFilter INTEGER
|
|
}
|
|
|
|
tnPtpClkConfIndex2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..CLOCK_INST_MAX]."
|
|
::= { tnPtpClkConf2Entry 1 }
|
|
|
|
tnPtpUtcOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Unicast Offset must be an integer value between 0 and 10000."
|
|
::= { tnPtpClkConf2Entry 2 }
|
|
|
|
tnPtpValid OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Valid."
|
|
::= { tnPtpClkConf2Entry 3 }
|
|
|
|
tnPtpLeap59 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Leap 59."
|
|
::= { tnPtpClkConf2Entry 4 }
|
|
|
|
tnPtpLeap61 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Leap 61."
|
|
::= { tnPtpClkConf2Entry 5 }
|
|
|
|
tnPtpTimeTrac OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Time Trac."
|
|
::= { tnPtpClkConf2Entry 6 }
|
|
|
|
tnPtpFreqTrac OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Freq Trac."
|
|
::= { tnPtpClkConf2Entry 7 }
|
|
|
|
tnPtpTimeScale OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Time Scale."
|
|
::= { tnPtpClkConf2Entry 8 }
|
|
|
|
tnPtpTimeSource OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Time Source. Value of 0-255"
|
|
::= { tnPtpClkConf2Entry 9 }
|
|
|
|
tnPtpDisplay OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "If true then Offset From Master, MeanPathDelay and clockAdjustment are logged on the debug terminal."
|
|
::= { tnPtpClkConf2Entry 10 }
|
|
|
|
tnPtpPEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "If true the P part of the algorithm is included."
|
|
::= { tnPtpClkConf2Entry 11 }
|
|
|
|
tnPtpIEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "If true the I part of the algorithm is included."
|
|
::= { tnPtpClkConf2Entry 12 }
|
|
|
|
tnPtpDEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "If true the D part of the algorithm is included."
|
|
::= { tnPtpClkConf2Entry 13 }
|
|
|
|
tnPtpPConstant OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The default clock servo uses a PID regulator to calculate the current clock rate. i.e.
|
|
clockAdjustment = OffsetFromMaster/ P constant + Integral(OffsetFromMaster)/ I constant +
|
|
Differential OffsetFromMaster)/ D constant [1..1000]."
|
|
::= { tnPtpClkConf2Entry 14 }
|
|
|
|
tnPtpIConstant OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The default clock servo uses a PID regulator to calculate the current clock rate. i.e.
|
|
clockAdjustment = OffsetFromMaster/ P constant + Integral(OffsetFromMaster)/ I constant +
|
|
Differential OffsetFromMaster)/ D constant [1..10000]."
|
|
::= { tnPtpClkConf2Entry 15 }
|
|
|
|
tnPtpDConstant OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The default clock servo uses a PID regulator to calculate the current clock rate. i.e.
|
|
clockAdjustment = OffsetFromMaster/ P constant + Integral(OffsetFromMaster)/ I constant +
|
|
Differential OffsetFromMaster)/ D constant [1..10000]."
|
|
::= { tnPtpClkConf2Entry 16 }
|
|
|
|
tnPtpServoDelayFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The default delay filter is a low pass filter, with a time constant of 2**DelayFilter*DelayRequestRate.
|
|
This is for the custom filter."
|
|
::= { tnPtpClkConf2Entry 17 }
|
|
|
|
--
|
|
-- PTP Unicast Slave Config
|
|
--
|
|
tnPtpUnicastSlaveTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnPtpUnicastSlaveEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of PTP Unicast Slave"
|
|
::= { tnPtp 6 }
|
|
|
|
tnPtpUnicastSlaveEntry OBJECT-TYPE
|
|
SYNTAX TnPtpUnicastSlaveEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table,tnPtpUnicastSlaveTable"
|
|
INDEX { tnPtpUnicastInstIndex, tnPtpUnicastSlaveIndex }
|
|
::= { tnPtpUnicastSlaveTable 1 }
|
|
|
|
|
|
TnPtpUnicastSlaveEntry ::= SEQUENCE
|
|
{
|
|
tnPtpUnicastInstIndex INTEGER,
|
|
tnPtpUnicastSlaveIndex INTEGER,
|
|
tnPtpUnicastDuration INTEGER,
|
|
tnPtpIPAddress InetAddress,
|
|
tnPtpGrant INTEGER,
|
|
tnPtpCommState INTEGER
|
|
}
|
|
|
|
tnPtpUnicastInstIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..3]."
|
|
::= { tnPtpUnicastSlaveEntry 1 }
|
|
|
|
tnPtpUnicastSlaveIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Indicates the Instance of a particular Unicast Slave [0..4]."
|
|
::= { tnPtpUnicastSlaveEntry 2 }
|
|
|
|
tnPtpUnicastDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The number of seconds a master is requested to send Announce/Sync messages.
|
|
The request is repeated from the slave each Duration/4 seconds. [10..1000]."
|
|
::= { tnPtpUnicastSlaveEntry 3 }
|
|
|
|
tnPtpIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "IPv4 Address of the Master clock."
|
|
::= { tnPtpUnicastSlaveEntry 4 }
|
|
|
|
tnPtpGrant OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The granted repetition period for the sync message."
|
|
::= { tnPtpUnicastSlaveEntry 5 }
|
|
|
|
tnPtpCommState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
idle(1),
|
|
init(2),
|
|
conn(3),
|
|
sell(4),
|
|
sync(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " The state of the communication with the master, possible values are:
|
|
IDLE : The entry is not in use.
|
|
INIT : Announce is sent to the master (Waiting for a response).
|
|
CONN : The master has responded.
|
|
SELL : The assigned master is selected as current master.
|
|
SYNC : The master is sending Sync messages."
|
|
::= { tnPtpUnicastSlaveEntry 6 }
|
|
|
|
--
|
|
-- PTP Clock Port Data Set Configuration
|
|
--
|
|
tnPtpPortConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnPtpPortConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of PTP Clock Port Data Set Configuration"
|
|
::= { tnPtp 7 }
|
|
|
|
tnPtpPortConfEntry OBJECT-TYPE
|
|
SYNTAX TnPtpPortConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table,tnPtpPortConfTable"
|
|
INDEX { tnPtpPortConfInstIndex, tnPtpPortConfIndex }
|
|
::= { tnPtpPortConfTable 1 }
|
|
|
|
|
|
TnPtpPortConfEntry ::= SEQUENCE
|
|
{
|
|
tnPtpPortConfInstIndex INTEGER,
|
|
tnPtpPortConfIndex INTEGER,
|
|
tnPtpStat OCTET STRING,
|
|
tnPtpMDR INTEGER,
|
|
tnPtpMeanPath OCTET STRING,
|
|
tnPtpAnv INTEGER,
|
|
tnPtpATO INTEGER,
|
|
tnPtpSyv INTEGER,
|
|
tnPtpSyncIntErr TruthValue,
|
|
tnPtpDim INTEGER,
|
|
tnPtpMPR INTEGER,
|
|
tnPtpDelayAsym INTEGER,
|
|
tnPtpIngerssLat INTEGER,
|
|
tnPtpEgressLat INTEGER,
|
|
tnPtpVersion INTEGER,
|
|
tnPtpPortConfRowStatus RowStatus
|
|
}
|
|
|
|
tnPtpPortConfInstIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..3]."
|
|
::= { tnPtpPortConfEntry 1 }
|
|
|
|
tnPtpPortConfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Static member port Identity : Port number [1..max port no]."
|
|
::= { tnPtpPortConfEntry 2 }
|
|
|
|
tnPtpStat OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Dynamic member portState: Current state of the port."
|
|
::= { tnPtpPortConfEntry 3 }
|
|
|
|
tnPtpMDR OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Dynamic member log Min Delay Req Interval: The delay request interval announced by the master."
|
|
::= { tnPtpPortConfEntry 4 }
|
|
|
|
tnPtpMeanPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The path delay measured by the port in P2P mode. In E2E mode this value is 0."
|
|
::= { tnPtpPortConfEntry 5 }
|
|
|
|
tnPtpAnv OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The interval for issuing announce messages in master state. [-3..4]"
|
|
::= { tnPtpPortConfEntry 6 }
|
|
|
|
tnPtpATO OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The timeout for receiving announce messages on the port. [-1..10]"
|
|
::= { tnPtpPortConfEntry 7 }
|
|
|
|
tnPtpSyv OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The interval for issuing sync messages in master. [-7..4]"
|
|
::= { tnPtpPortConfEntry 8 }
|
|
|
|
tnPtpSyncIntErr OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Synce Interval Error truth value"
|
|
::= { tnPtpPortConfEntry 9 }
|
|
|
|
tnPtpDim OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
e2e(1),
|
|
p2p(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Configurable member delayMechanism: The delay mechanism used for the port:
|
|
e2e End to end delay measurement
|
|
p2p Peer to peer delay measurement.
|
|
Can be defined per port in an Ordinary/Boundary clock.
|
|
In a transparent clock all ports use the same delay mechanism, determined by the clock type."
|
|
::= { tnPtpPortConfEntry 10 }
|
|
|
|
tnPtpMPR OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The interval for issuing Delay_Req messages for the port in E2e mode.
|
|
This value is announced from the master to the slave in an announce message. The value is reflected in the MDR field in the Slave
|
|
The interval for issuing Pdelay_Req messages for the port in P2P mode
|
|
Note: The interpretation of this parameter has changed from release 2.40.
|
|
In earlier versions the value was interpreted relative to the Sync interval, this was a violation of the standard, so now the value is interpreted as an interval.
|
|
I.e. MPR = 0 =>1 Delay_Req pr sec, independent of the Sync rate. [-7..5]"
|
|
::= { tnPtpPortConfEntry 11 }
|
|
|
|
tnPtpDelayAsym OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "If the transmission delay for a link in not symmetric, the asymmetry can be configured here,
|
|
see IEEE 1588 Section 7.4.2 Communication path asymmetry. [-100000..100000]"
|
|
::= { tnPtpPortConfEntry 12 }
|
|
|
|
tnPtpIngerssLat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Ingress latency measured in ns, as defined in IEEE 1588 Section 7.3.4.2. [-100000..100000]"
|
|
::= { tnPtpPortConfEntry 13 }
|
|
|
|
tnPtpEgressLat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Egress latency measured in ns, as defined in IEEE 1588 Section 7.3.4.2. [-100000..100000]"
|
|
::= { tnPtpPortConfEntry 14 }
|
|
|
|
tnPtpVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The current implementation only supports PTP version 2."
|
|
::= { tnPtpPortConfEntry 15 }
|
|
|
|
tnPtpPortConfRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the row.
|
|
|
|
The writable columns in a row cannot be changed if the row
|
|
is active. All columns must have a valid value before a row
|
|
can be activated.
|
|
"
|
|
::= { tnPtpPortConfEntry 16 }
|
|
END |