-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-ROUTE-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-ROUTE-MIB DEFINITIONS ::= BEGIN
IMPORTS
Ipv6Address
FROM IPV6-TC
routingProtocols
FROM PRVT-SWITCH-MIB
IpAddress, MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
RowStatus, TEXTUAL-CONVENTION, TruthValue
FROM SNMPv2-TC;
prvtRouteMIB MODULE-IDENTITY
LAST-UPDATED "200901270000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"Mib containing information about
dynamic and configurable routes in the system."
REVISION "200901270000Z"
DESCRIPTION
"Initial version"
::= { routingProtocols 3 }
NetPrefix ::= TEXTUAL-CONVENTION
DISPLAY-HINT "1d.1d.1d.1d/1d"
STATUS current
DESCRIPTION
"Prefix"
SYNTAX OCTET STRING
prvtRouteMIBObjects OBJECT IDENTIFIER
::= { prvtRouteMIB 1 }
prvtDynamicRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtDynamicRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"System dynamic routes."
::= { prvtRouteMIBObjects 1 }
prvtDynamicRouteEntry OBJECT-TYPE
SYNTAX PrvtDynamicRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row represents a routing entry."
INDEX { prvtDynamicRoutePrefix, prvtDynamicRouteNextHop,
prvtDynamicRouteType, prvtDynamicRouteDistance }
::= { prvtDynamicRouteTable 1 }
PrvtDynamicRouteEntry ::= SEQUENCE {
prvtDynamicRoutePrefix OCTET STRING,
prvtDynamicRouteNextHop IpAddress,
prvtDynamicRouteType INTEGER,
prvtDynamicRouteDistance Unsigned32,
prvtDynamicRouteFlags BITS,
prvtDynamicRouteNextHopType INTEGER,
prvtDynamicRouteNextHopFlags BITS,
prvtDynamicRouteMetrics Unsigned32,
prvtDynamicRouteUptime OCTET STRING,
prvtDynamicRouteIfName OCTET STRING
}
prvtDynamicRoutePrefix OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(5))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Dynamic route prefix."
::= { prvtDynamicRouteEntry 1 }
prvtDynamicRouteNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Dynamic route next hop."
::= { prvtDynamicRouteEntry 2 }
prvtDynamicRouteType OBJECT-TYPE
SYNTAX INTEGER { system(1), kernel(2), connect(3), static(4),
rip(5), ripng(6), ospf(7), ospf6(8), bgp(9), fib(10),
vrrp(11), irdp(12), dhcp(13), pimd(14), isis1(15),
isis2(16), bfd(17), test(18), max(19) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Dynamic route type."
::= { prvtDynamicRouteEntry 3 }
prvtDynamicRouteDistance OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Dynamic route distance."
::= { prvtDynamicRouteEntry 4 }
prvtDynamicRouteFlags OBJECT-TYPE
SYNTAX BITS { internal(0), selfroute(1), blackhole(2), ibgp(3),
selected(4), changed(5), static(6), deleted(7),
staticarp(8), mplsIngress(9), mplsEgress(10),
outband(11), selfIp(12), vrrpIp(13) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dynamic route flags."
::= { prvtDynamicRouteEntry 5 }
prvtDynamicRouteNextHopType OBJECT-TYPE
SYNTAX INTEGER { ifindex(1), ifname(2), ipv4(3), ipv4Ifindex(4),
ipv4Ifname(5), ipv6(6), ipv6Ifindex(7),
ipv6Ifname(8) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dynamic route hop type."
::= { prvtDynamicRouteEntry 6 }
prvtDynamicRouteNextHopFlags OBJECT-TYPE
SYNTAX BITS { active(0), fib(1), recursive(2), notready(3),
outband(4), fibsetOutband(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dynamic route hop flags."
::= { prvtDynamicRouteEntry 7 }
prvtDynamicRouteMetrics OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dynamic route metrics."
::= { prvtDynamicRouteEntry 8 }
prvtDynamicRouteUptime OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A length of time.
Duration values are in the ISO 8601 duration format, where
P represents 'Period',
nY represents the number of years,
nM the number of months,
nD the number of days,
T is the date/time separator,
nH the number of hours,
nM the number of minutes,
nS the number of seconds.
So P2DT23H32M51S means 'A period of 2 days, 23 hours, 32 minutes, and 51 seconds'.
PnYnMnDTnH nMnS (e.g., P2DT23H32M51S)
We use the duration data type to convey values like
the time left until a listing ends.
For ended listings, the time left is PT0S (zero seconds).
xs:duration is part of the XML schema namespace defined as:
xmlns:xs='http://www.w3.org/2001/XMLSchema' "
::= { prvtDynamicRouteEntry 9 }
prvtDynamicRouteIfName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dynamic route name."
::= { prvtDynamicRouteEntry 10 }
prvtCfgRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfgRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with configurable routes. To create entry in
this table use prvtCfgRouteRowStatus with
createAndGo(4) or createAndWait(5).
For example static route :
static-route 88.65.85.4/32 43.13.15.18 3
will be represented as :
prvtCfgRouteRowStatus.88.65.85.4.32.43.13.15.18.3"
::= { prvtRouteMIBObjects 2 }
prvtCfgRouteEntry OBJECT-TYPE
SYNTAX PrvtCfgRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row represents a routing entry."
INDEX { prvtCfgRoutePrefix, prvtCfgRouteNextHop,
prvtCfgRouteDistance }
::= { prvtCfgRouteTable 1 }
PrvtCfgRouteEntry ::= SEQUENCE {
prvtCfgRoutePrefix OCTET STRING,
prvtCfgRouteNextHop IpAddress,
prvtCfgRouteDistance Unsigned32,
prvtCfgRouteRowStatus RowStatus
}
prvtCfgRoutePrefix OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(5))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Route prefix."
::= { prvtCfgRouteEntry 1 }
prvtCfgRouteNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Route next hop."
::= { prvtCfgRouteEntry 2 }
prvtCfgRouteDistance OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Route distance."
::= { prvtCfgRouteEntry 3 }
prvtCfgRouteRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Create static route."
::= { prvtCfgRouteEntry 4 }
prvtCfgIPv6RouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfgIPv6RouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with configurable routes. To create entry in
this table use prvtCfgIPv6RouteRowStatus with
createAndGo(4) or createAndWait(5).
For example static route :
router static-ipv6-route ::/0 2001:fd8::7 10
will be represented as :
prvtCfgIPv6RouteRowStatus.4.58.58.47.48.32.1.15.216.0.0.0.0.0.0.0.0.0.0.0.7.10
or
1.3.6.1.4.1.738.10.6.4.3.1.3.1.4 --> prvtCfgIPv6RouteRowStatus OID
v --> Value --> createAndGo(4)
prvtCfgIPv6RouteRowStatus <--|v : : / 0 2001:0f d8: 00: 00: 00: 00: 00: 07|10
1.3.6.1.4.1.738.10.6.4.3.1.3.1.4.4.58.58.47.48.32.1.15.216.0.0.0.0.0.0.0.0.0.0.0.7.10"
::= { prvtRouteMIBObjects 3 }
prvtCfgIPv6RouteEntry OBJECT-TYPE
SYNTAX PrvtCfgIPv6RouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row represents a IPv6 routing entry."
INDEX { prvtCfgIPv6RoutePrefix, prvtCfgIPv6RouteNextHop,
prvtCfgIPv6RouteDistance }
::= { prvtCfgIPv6RouteTable 1 }
PrvtCfgIPv6RouteEntry ::= SEQUENCE {
prvtCfgIPv6RoutePrefix OCTET STRING,
prvtCfgIPv6RouteNextHop Ipv6Address,
prvtCfgIPv6RouteDistance Unsigned32,
prvtCfgIPv6RouteRowStatus RowStatus
}
prvtCfgIPv6RoutePrefix OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IPv6 route prefix."
::= { prvtCfgIPv6RouteEntry 1 }
prvtCfgIPv6RouteNextHop OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IPv6 route next hop."
::= { prvtCfgIPv6RouteEntry 2 }
prvtCfgIPv6RouteDistance OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IPv6 route distance."
::= { prvtCfgIPv6RouteEntry 3 }
prvtCfgIPv6RouteRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Create static IPv6 route."
::= { prvtCfgIPv6RouteEntry 4 }
prvtGlobalIPv6Forwarding OBJECT-TYPE
SYNTAX INTEGER { host(1), router(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure IPv6 behavior."
::= { prvtRouteMIBObjects 4 }
prvtGlobalIPv6Disable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure IPv6 behavior."
::= { prvtRouteMIBObjects 5 }