-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-ALARM-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-ALARM-MIB DEFINITIONS ::= BEGIN
IMPORTS
software
FROM PRVT-SWITCH-MIB
Counter32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
Unsigned32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC;
prvtAlarmMIB MODULE-IDENTITY
LAST-UPDATED "201303250000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"Information for current snmp allarms"
REVISION "201303250000Z"
DESCRIPTION
"Initial implementation."
::= { software 4 }
prvtAlarmMIBObjects OBJECT IDENTIFIER
::= { prvtAlarmMIB 1 }
prvtUpdatedCurrentAlarmCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last updated alarm counter"
::= { prvtAlarmMIBObjects 1 }
prvtAlarmCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtAlarmCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains current alarms."
::= { prvtAlarmMIBObjects 2 }
prvtAlarmCurrentEntry OBJECT-TYPE
SYNTAX PrvtAlarmCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in prvtAlarmCurrentTable containing the info of a
current RAISED trap."
INDEX { prvtAlarmCurrentCounter }
::= { prvtAlarmCurrentTable 1 }
PrvtAlarmCurrentEntry ::= SEQUENCE {
prvtAlarmCurrentCounter Counter32,
prvtAlarmCurrentRaisedTime Unsigned32,
prvtAlarmCurrentSeverity INTEGER,
prvtAlarmCurrentDescription OCTET STRING
}
prvtAlarmCurrentCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A running counter of open alarms, the counter
is incremented on every new alarm. It is cleared after reset."
::= { prvtAlarmCurrentEntry 1 }
prvtAlarmCurrentRaisedTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The raised time of this alarm.
Time in seconds since January 1, 1970 00:00 UTC."
::= { prvtAlarmCurrentEntry 2 }
prvtAlarmCurrentSeverity OBJECT-TYPE
SYNTAX INTEGER { clear(0), event(1), warning(2), minor(3),
major(4), critical(5), unknown(99) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current alarm severity"
::= { prvtAlarmCurrentEntry 3 }
prvtAlarmCurrentDescription OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm description."
::= { prvtAlarmCurrentEntry 4 }
END -- end of module PRVT-ALARM-MIB.