- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
169 lines
6 KiB
Text
169 lines
6 KiB
Text
-- *********************************************************************
|
|
-- **
|
|
-- ** BATM Advanced Communications.
|
|
-- **
|
|
-- *********************************************************************
|
|
-- ** Filename: PRVT-UPS-MIB.mib
|
|
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
|
|
-- ** Purpose: Private MIB
|
|
-- *********************************************************************
|
|
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
|
|
-- WARNING:
|
|
--
|
|
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
|
|
--
|
|
-- This file is the property of BATM Advanced Communications and contains
|
|
-- proprietary and confidential information. This file is made
|
|
-- available to authorized BATM customers on the express
|
|
-- condition that neither it, nor any of the information contained
|
|
-- therein, shall be disclosed to third parties or be used for any
|
|
-- purpose other than to replace, modify or upgrade firmware and/or
|
|
-- software components of BATM manufactured equipment within the
|
|
-- authorized customer's network, and that such transfer be
|
|
-- completed in accordance with the instructions provided by
|
|
-- BATM. Any other use is strictly prohibited.
|
|
--
|
|
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
|
|
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
|
|
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
|
|
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
|
|
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
|
|
--
|
|
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
|
|
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
|
|
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
|
|
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
|
|
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
|
|
--
|
|
-- ----------------------------------------------------------------------------
|
|
--
|
|
PRVT-UPS-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
NOTIFICATION-GROUP FROM SNMPv2-CONF
|
|
|
|
|
|
switch
|
|
FROM PRVT-SWITCH-MIB;
|
|
|
|
|
|
prvtUPSMib MODULE-IDENTITY
|
|
LAST-UPDATED "200801010000Z"
|
|
ORGANIZATION "BATM Advanced Communication"
|
|
CONTACT-INFO
|
|
|
|
"BATM/Telco Systems Support team
|
|
Email:
|
|
For North America: techsupport@telco.com
|
|
For North Europe: support@batm.de, info@batm.de
|
|
For the rest of the world: techsupport@telco.com"
|
|
|
|
DESCRIPTION
|
|
"MIB module for monitoring the UPS connected to switch or ipSwitch"
|
|
|
|
-- revision history
|
|
REVISION "200801010000Z"
|
|
DESCRIPTION
|
|
"Removed redefined OIDs in private vendor extension definitions."
|
|
REVISION "200502160000Z"
|
|
DESCRIPTION
|
|
"Fixed spelling errors and changed the contact info."
|
|
|
|
REVISION "200305080000Z"
|
|
DESCRIPTION
|
|
"Move to SMI-V2."
|
|
|
|
REVISION "200201280000Z"
|
|
DESCRIPTION
|
|
"Initial version."
|
|
::= { switch 103 }
|
|
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- UPS parameters
|
|
-- -----------------------------------------------------------------------------
|
|
prvtUPSNotifications OBJECT IDENTIFIER ::= { prvtUPSMib 0 }
|
|
upsStatus OBJECT IDENTIFIER ::= { prvtUPSMib 1 }
|
|
prvtUPSConformance OBJECT IDENTIFIER ::= { prvtUPSMib 2 }
|
|
|
|
upsConnectedStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
connected(1),
|
|
disconnected(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates, if a UPS is connected to the device."
|
|
::= { upsStatus 1 }
|
|
|
|
upsLinePowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
fromExternalConnection(2),
|
|
fromInternalBattery(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the external AD power line status:
|
|
the UPS is supplying the power from the internal battery
|
|
or from an external AC power connection."
|
|
::= { upsStatus 2 }
|
|
|
|
upsBatteryStorageStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
moreThan30Minutes(2),
|
|
lessThan30Minutes(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows the estimated time left until the UPS battery
|
|
will discharge to the level at which the UPS must shutdown."
|
|
::= { upsStatus 3 }
|
|
|
|
upsInternalStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
ok(2),
|
|
failure(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows if the UPS has some kind of an internal
|
|
failure."
|
|
::= { upsStatus 4 }
|
|
|
|
-- Traps for use by prvtUPSMib
|
|
|
|
upsStatusChange NOTIFICATION-TYPE
|
|
OBJECTS { upsConnectedStatus,upsLinePowerStatus,
|
|
upsBatteryStorageStatus,upsInternalStatus}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsStatusChange trap indicates that the sending
|
|
agent monitor detected a change in the status of the external
|
|
UPS, connected to the device."
|
|
::= {prvtUPSNotifications 1}
|
|
|
|
-- *******************************************************************
|
|
-- Conformance Information
|
|
-- *******************************************************************
|
|
|
|
prvtUPSMIBGroups OBJECT IDENTIFIER ::= { prvtUPSConformance 2 }
|
|
|
|
|
|
prvtUPSNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
upsStatusChange
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Private Notification Group."
|
|
::= { prvtUPSMIBGroups 3 }
|
|
|
|
END
|