- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
102 lines
2.6 KiB
Text
102 lines
2.6 KiB
Text
-- This module defines enterprise MIBs for time and NTP setting
|
|
--
|
|
-- Copyright (c) 1999-2004, Juniper Networks, Inc.
|
|
-- All rights reserved.
|
|
|
|
NETSCREEN-SET-SYSTIME-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
netscreenSetting, netscreenSettingMibModule
|
|
FROM NETSCREEN-SMI
|
|
Integer32, IpAddress, MODULE-IDENTITY, OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
;
|
|
|
|
netscreenSetSystimeMibModule MODULE-IDENTITY
|
|
LAST-UPDATED "200405032022Z" -- May 03, 2004
|
|
ORGANIZATION
|
|
"Juniper Networks, Inc."
|
|
CONTACT-INFO
|
|
"Customer Support
|
|
|
|
1194 North Mathilda Avenue
|
|
Sunnyvale, California 94089-1206
|
|
USA
|
|
|
|
Tel: 1-800-638-8296
|
|
E-mail: customerservice@juniper.net
|
|
HTTP://www.juniper.net"
|
|
DESCRIPTION
|
|
"This module defines the object that are used to monitor
|
|
NTP setting"
|
|
REVISION "200405030000Z" -- May 03, 2004
|
|
DESCRIPTION
|
|
"Modified copyright and contact information"
|
|
REVISION "200403030000Z" -- March 03, 2004
|
|
DESCRIPTION
|
|
"Converted to SMIv2 by Longview Software"
|
|
REVISION "200311120000Z" -- November 12, 2003
|
|
DESCRIPTION
|
|
"Correct wrong title"
|
|
REVISION "200109280000Z" -- September 28, 2001
|
|
DESCRIPTION
|
|
"No Comment"
|
|
REVISION "200105270000Z" -- May 27, 2001
|
|
DESCRIPTION
|
|
"Creation Date"
|
|
::= { netscreenSettingMibModule 6 }
|
|
|
|
nsSetSysTime OBJECT IDENTIFIER ::= { netscreenSetting 6 }
|
|
|
|
nsSetSysTimeGmtOffset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"GMT time offset of system time"
|
|
::= { nsSetSysTime 1 }
|
|
|
|
nsSetSysTimeDaySaving OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"enable daylight time saving method."
|
|
::= { nsSetSysTime 2 }
|
|
|
|
nsSetSysTimeNTP OBJECT IDENTIFIER ::= { nsSetSysTime 3 }
|
|
|
|
nsSetNtpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable Network Time Protocol"
|
|
::= { nsSetSysTimeNTP 1 }
|
|
|
|
nsSetNtpServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network Time Server ip"
|
|
::= { nsSetSysTimeNTP 2 }
|
|
|
|
nsSetNtpUpdateInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If NetScreen device use NTP to get system time. This object
|
|
indicate the update system clock time interval."
|
|
::= { nsSetSysTimeNTP 3 }
|
|
|
|
END
|
|
|
|
|