- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
138 lines
3.5 KiB
Text
138 lines
3.5 KiB
Text
NBS-FEC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
|
|
nbs
|
|
FROM NBS-MIB;
|
|
|
|
nbsFecMib MODULE-IDENTITY
|
|
LAST-UPDATED "201504290000Z" -- April 29, 2015
|
|
ORGANIZATION "NBS"
|
|
CONTACT-INFO
|
|
"For technical support, please contact your service channel"
|
|
DESCRIPTION
|
|
"Forward Error Correction"
|
|
::= { nbs 232 }
|
|
|
|
-- *******************************************************************
|
|
-- NBS-FEC-MIB textual conventions
|
|
-- *******************************************************************
|
|
|
|
NbsFecCode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Particular FEC Algorithm/Code"
|
|
SYNTAX INTEGER {
|
|
notSupported (0),
|
|
noFec (1),
|
|
zero (2),
|
|
gfec (3),
|
|
ufec7 (4),
|
|
ufec10 (5),
|
|
ufec25 (6),
|
|
hgfec7 (7),
|
|
sdfec0 (8),
|
|
sdfec1 (9),
|
|
sdfec2 (10),
|
|
sdfec3 (11),
|
|
g975i4 (12),
|
|
g975i7 (13),
|
|
xfec7 (14),
|
|
sdfec15 (15)
|
|
}
|
|
|
|
-- *******************************************************************
|
|
-- NBS-FEC-MIB groups
|
|
-- *******************************************************************
|
|
|
|
nbsFecCfgGrp OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FEC configuration"
|
|
::= { nbsFecMib 1 }
|
|
|
|
|
|
-- *******************************************************************
|
|
--
|
|
-- the nbsFecCfgGrp
|
|
--
|
|
-- *******************************************************************
|
|
|
|
|
|
nbsFecCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NbsFecCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FEC settings for all supported ports"
|
|
::= { nbsFecCfgGrp 1 }
|
|
|
|
nbsFecCfgEntry OBJECT-TYPE
|
|
SYNTAX NbsFecCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FEC settings for an individual port"
|
|
INDEX { nbsFecCfgIfIndex }
|
|
::= { nbsFecCfgTable 1 }
|
|
|
|
NbsFecCfgEntry ::= SEQUENCE {
|
|
nbsFecCfgIfIndex InterfaceIndex,
|
|
nbsFecCfgCodeCaps OCTET STRING,
|
|
nbsFecCfgCodeAdmin NbsFecCode,
|
|
nbsFecCfgCodeOper NbsFecCode
|
|
}
|
|
|
|
nbsFecCfgIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The mib2 ifIndex"
|
|
::= { nbsFecCfgEntry 1 }
|
|
|
|
nbsFecCfgCodeCaps OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(3))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This bitmask indicates which FEC codes this port can
|
|
support.
|
|
|
|
Bit 0 is reserved.
|
|
|
|
Subsequent bits refer to the NbsFecCode enumerated list. Bit 1
|
|
corresponds to none(1), Bit 2 to zero(2) enumeration,
|
|
and so on. A bit is set (1) if that code is appropriate
|
|
for this module, cleared (0) if unavailable.
|
|
|
|
OCTET STRING bitmasks count the leftmost bit (MSB) as 0."
|
|
::= { nbsFecCfgEntry 2 }
|
|
|
|
nbsFecCfgCodeAdmin OBJECT-TYPE
|
|
SYNTAX NbsFecCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administratively desired Forward Error Correction code"
|
|
::= { nbsFecCfgEntry 3 }
|
|
|
|
|
|
nbsFecCfgCodeOper OBJECT-TYPE
|
|
SYNTAX NbsFecCode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operationally active Forward Error Correction code"
|
|
::= { nbsFecCfgEntry 4}
|
|
|
|
|
|
END
|