- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
3622 lines
150 KiB
Text
3622 lines
150 KiB
Text
|
|
-- *****************************************************************************
|
|
-- Juniper-System-MIB
|
|
--
|
|
-- Juniper Networks Enterprise MIB
|
|
-- E-series System MIB
|
|
--
|
|
-- Copyright (c) 2002-2008 Juniper Networks, Inc. All Rights Reserved.
|
|
-- *****************************************************************************
|
|
|
|
Juniper-System-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32,
|
|
Gauge32, TimeTicks
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, DisplayString, TruthValue, DateAndTime
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
PhysicalIndex, entPhysicalDescr
|
|
FROM ENTITY-MIB
|
|
KBytes
|
|
FROM HOST-RESOURCES-MIB
|
|
InterfaceIndexOrZero
|
|
FROM IF-MIB
|
|
juniMibs
|
|
FROM Juniper-MIBs
|
|
JuniEnable, JuniTimeFilter
|
|
FROM Juniper-TC;
|
|
|
|
juniSystemMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200806111101Z" -- 11-Jun-08 07:01 AM EDT
|
|
ORGANIZATION "Juniper Networks, Inc."
|
|
CONTACT-INFO
|
|
" Juniper Networks, Inc.
|
|
Postal: 10 Technology Park Drive
|
|
Westford, MA 01886-3146
|
|
USA
|
|
Tel: +1 978 589 5800
|
|
Email: mib@Juniper.net"
|
|
DESCRIPTION
|
|
"The MIB objects for managing a Juniper E-series (JUNOSe) system. This
|
|
MIB complements the ENTITY-MIB.entPhysicalTable by providing the
|
|
system's physical information in a format that is more user friendly and
|
|
provides additional elements not found in the Entity MIB, including
|
|
state information, parameters for configuring the system and additional
|
|
notifications.
|
|
|
|
There are two families of E-series hardware systems supported by this
|
|
MIB:
|
|
ERX - first generation E-series systems
|
|
ES2 - second generation E-series systems "
|
|
-- Revision History
|
|
REVISION "200806111101Z" -- 11-Jun-08 07:01 AM EDT - JUNOSe 10.0
|
|
DESCRIPTION
|
|
"Added es2Lm10s support."
|
|
REVISION "200805051241Z" -- 05-May-08 08:41 AM EDT - JUNOSe 9.2
|
|
DESCRIPTION
|
|
"Add ISSU Support for ERX-1440."
|
|
REVISION "200705071012Z" -- 07-May-07 06:12 AM EDT - JUNOSe 9.0
|
|
DESCRIPTION
|
|
"Add ISSU support."
|
|
REVISION "200612182125Z" -- 18-Dec-06 04:25 PM EST - JUNOSe 8.3
|
|
DESCRIPTION
|
|
"Add LM10 Access Support."
|
|
REVISION "200611240913Z" -- 24-Nov-06 04:13 AM EST - JUNOSe 8.2
|
|
DESCRIPTION
|
|
"Add suppot for ES2 primary modules SRP-120 and SFM-120 for E120."
|
|
REVISION "200605180831Z" -- 18-May-06 02:01 PM EST - JUNOSe 8.0
|
|
DESCRIPTION
|
|
"Add last 5 seconds, 1 minute and 5 minutes avergae CPU utilzation
|
|
support."
|
|
REVISION "200601061817Z" -- 06-Jan-06 01:17 PM EST - JUNOSe main
|
|
DESCRIPTION
|
|
"Add LM10 Access Support."
|
|
REVISION "200512160721Z" -- 16-Dec-05 12:51 PM EST - JUNOSe main
|
|
DESCRIPTION
|
|
"Changed maximum value of juniSystemHighMemUtilThreshold from 100 to 99
|
|
and maximum value of juniSystemAbatedMemUtilThreshold from 99 to 98."
|
|
REVISION "200511182230Z" -- 18-Nov-05 05:30 PM EST - JUNOSe 7.3
|
|
DESCRIPTION
|
|
"Add CPU utilization statitics table support."
|
|
REVISION "200509151414Z" -- 15-Sep-05 10:14 AM EDT - JUNOSe 7.2
|
|
DESCRIPTION
|
|
"Add LM10 Uplink Support."
|
|
REVISION "200508191748Z" -- 29-Jul-05 01:48 PM EDT - JUNOSe main
|
|
DESCRIPTION
|
|
"Add Ge8 support."
|
|
REVISION "200507291748Z" -- 29-Jul-05 01:48 PM EDT - JUNOSe 7.0.1
|
|
DESCRIPTION
|
|
"conform to REX Naming Document, renamed various ES2 module types
|
|
and deleted ones that didn't belong."
|
|
REVISION "200505181810Z" -- 18-May-05 02:10 PM EDT - JUNOSe 7.0.0
|
|
DESCRIPTION
|
|
"Updated JuniSystemModuleType TC and created JuniSystemSlotLevel TC."
|
|
REVISION "200505041810Z" -- 04-May-05 02:10 PM EDT - JUNOSe 7.0.0
|
|
DESCRIPTION
|
|
"Added GE-HDE support."
|
|
REVISION "200501311813Z" -- 31-Jan-05 02:13 PM EDT - JUNOSe 5.1.5
|
|
DESCRIPTION
|
|
"Added KByte memory capacity object to notification."
|
|
REVISION "200412311013Z" -- 31-Dec-04 05:13 AM EST - JUNOSe main
|
|
DESCRIPTION
|
|
"Updated for second generation E-series router."
|
|
|
|
REVISION "200412291010Z" -- 29-Dec-04 05:10 AM EST - JUNOSe 6.1
|
|
DESCRIPTION
|
|
"Updated SystemTimingSelector TC and related timing objects."
|
|
REVISION "200405251813Z" -- 25-May-04 02:13 PM EDT - JUNOSe 6.1
|
|
DESCRIPTION
|
|
"Added support for the Fe8 FX IOA."
|
|
REVISION "200401072246Z" -- 07-Jan-04 05:46 PM EST - JUNOSe 6.0
|
|
DESCRIPTION
|
|
"Added support for the second generation E-series hardware
|
|
architecture."
|
|
REVISION "200311242059Z" -- 24-Nov-03 03:59 PM EST - JUNOSe 5.3
|
|
DESCRIPTION
|
|
"Added Hybrid Primary Module and Hybrid IOA modules.
|
|
Added GE2 Primary Module and GE2 IOA module."
|
|
REVISION "200311241939Z" -- 24-Nov-03 02:39 PM EST - JUNOSe 5.2
|
|
DESCRIPTION
|
|
"Added resource utilization notification enable/disable.
|
|
Added KByte memory capacilty object."
|
|
REVISION "200307221410Z" -- 22-Jul-03 10:10 AM EDT - JUNOSe 5.1
|
|
DESCRIPTION
|
|
"Added ERX-310 support."
|
|
REVISION "200301272122Z" -- 27-Jan-03 04:22 PM EST - JUNOSe 5.0
|
|
DESCRIPTION
|
|
"Replaced Unisphere names with Juniper names.
|
|
Added resource utilization notification support."
|
|
REVISION "200210172101Z" -- 17-Oct-02 05:01 PM EDT - JUNOSe 4.1
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { juniMibs 2 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Textual conventions
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
JuniSystemModuleType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 'personality' type of a module found in an E-series system. Some
|
|
primary modules (e.g., line cards) have only one personality; that is
|
|
they only accept one personality of other level modules (e.g. I/O
|
|
adapters) in the same slot and are always configured in the same way.
|
|
Other modules are multi-personality and will behave differently
|
|
depending on the other level modules they are operating with, and
|
|
therefore cannot be configured without knowing the other level module
|
|
type(s). Type values in this table include both. Types that are
|
|
multi-personality are noted by [MP] and types that are personality-only
|
|
are noted by [PO]. Use the ENTITY-MIB to deretmine the actual hardware
|
|
type of a module with personality-only type.
|
|
|
|
unknown Unknown module type
|
|
ERX primary modules:
|
|
erxSrp ERX Switch/Route Processor
|
|
erxCt3 ERX 3 port Channelized T3
|
|
erxOc3 ERX 2 port OC3 SONET/SDH
|
|
erxUt3Atm ERX 3 port Unchannelized T3 ATM
|
|
erxUt3Frame ERX 3 port Unchannelized T3 Frame
|
|
erxUe3Atm ERX 3 port Unchannelized E3 ATM
|
|
erxUe3Frame ERX 3 port Uncahnnelized E3 Frame
|
|
erxCe1 ERX 20 port Channelized E1
|
|
erxCt1 ERX 24 port Channelized T1
|
|
erxDpfe ERX 2 port Fast Ethernet
|
|
erxOc12Pos ERX 1 port OC12 POS
|
|
erxOc12Atm ERX 1 port OC12 ATM
|
|
erxOc3Pos ERX 4 port OC3 POS
|
|
erxOc3Atm ERX 4 port OC3 ATM
|
|
erxGe ERX 1 port Gigabit Ethernet [PO]
|
|
erxFe8 ERX 8 port Fast Ethernet [PO]
|
|
erxOc3oc12Pos ERX OC3/OC12 POS [MP]
|
|
erxOc3oc12Atm ERX OC3/OC12 ATM [MP]
|
|
erxCoc3oc12 ERX Channelized OC3/OC12 [MP]
|
|
erxCoc3 ERX 4 port Channelized OC3 [PO]
|
|
erxCoc12 ERX 1 port Channelized OC12 [PO]
|
|
erxOc12Server ERX 1 port OC12 Tunnel Server
|
|
erxHssi ERX 3 port High Speed Serial Interface
|
|
erxGeFe ERX Gigabit Ethernet / Fast Ethernet [MP]
|
|
erxCt3P12 ERX 12 port Channelized T3
|
|
erxV35 ERX 16 port X.21/V.35
|
|
erxUt3f12 ERX 12 port Unchannelized T3 Frame [PO]
|
|
erxUe3f12 ERX 12 port Unchannelized E3 Frame [PO]
|
|
erxCoc12F3 ERX 1 port OC12 channelized to T3/E3 [PO]
|
|
erxCoc3F3 ERX 4 port OC3 channelized to T3/E3 [PO]
|
|
erxCocxF3 ERX OC3/OC12 channelized to T3/E3 [MP]
|
|
erxVts ERX Virtual Tunnel Server
|
|
erxOc48 ERX 1 port OC48 SONET/SDH
|
|
erxUt3Atm4 ERX 4 port Unchannelized T3/E3 ATM [PO]
|
|
erxHybrid ERX ATM / POS / Gigabit Ethernet Hybrid [MP]
|
|
erxOc3AtmGe ERX 2 port OC3 ATM 1 port Gigabit Ethernet [PO]
|
|
erxOc3AtmPos ERX 2 port OC3 ATM 2 port OC3 POS [PO]
|
|
erxGe2 ERX 2 port Gigabit Ethernet
|
|
erxGeHde ERX 2/8 port Gigabit Ethernet
|
|
ERX I/O adapter (IOA) modules:
|
|
erxSrpIoa ERX Switch/Route Processor IOA
|
|
erxCt1Ioa ERX 24 port channelized T1/J1 IOA
|
|
erxCe1Ioa ERX 20 port channelized E1 IOA
|
|
erxCe1TIoa ERX 20 port channelized E1 Telco IOA
|
|
erxCt3Ioa ERX 3 port channelized T3/E3 IOA
|
|
erxE3Ioa ERX 3 port E3 IOA
|
|
erxOc3Mm2Ioa ERX 2 port OC3 multi-mode IOA
|
|
erxOc3Sm2Ioa ERX 2 port OC3 single-mode IOA
|
|
erxOc3Mm4Ioa ERX 4 port OC3 multi-mode IOA
|
|
erxOc3SmIr4Ioa ERX 4 port OC3 single-mode
|
|
intermediate-reach IOA
|
|
erxOc3SmLr4Ioa ERX 4 port OC3 single-mode long-reach IOA
|
|
erxCOc3Mm4Ioa ERX 4 port channelized OC3 multi-mode IOA
|
|
erxCOc3SmIr4Ioa ERX 4 port channelized OC3 single-mode
|
|
intermediate-reach IOA
|
|
erxCOc3SmLr4Ioa ERX 4 port channelized OC3 single-mode
|
|
long-reach IOA
|
|
erxOc12Mm1Ioa ERX 1 port OC12 multi-mode IOA
|
|
erxOc12SmIr1Ioa ERX 1 port OC12 single-mode
|
|
intermediate-reach IOA
|
|
erxOc12SmLr1Ioa ERX 1 port OC12 single-mode long-reach IOA
|
|
erxCOc12Mm1Ioa ERX 1 port channelized OC12 multi-mode IOA
|
|
erxCOc12SmIr1Ioa ERX 1 port channelized OC12 single-mode
|
|
intermediate-reach IOA
|
|
erxCOc12SmLr1Ioa ERX 1 port channelized OC12 single-mode
|
|
long-reach IOA
|
|
erxFe2Ioa ERX 2 port 10/100 Fast Ethernet IOA
|
|
erxFe8Ioa ERX 8 port 10/100 Fast Ethernet IOA
|
|
erxGeMm1Ioa ERX 1 port Gigabit Ethernet multi-mode IOA
|
|
erxGeSm1Ioa ERX 1 port Gigabit Ethernet single-mode
|
|
IOA
|
|
erxHssiIoa ERX 3 port High Speed Serial Interface IOA
|
|
erxCt3P12Ioa ERX 12 port channelized and unchannelized
|
|
T3 IOA
|
|
erxV35Ioa ERX 16 port X2.1/V3.5 IOA
|
|
erxGeSfpIoa ERX 1 port Gigabit Ethernet SFP IOA
|
|
erxUe3P12Ioa ERX 12 port unchannelized E3 IOA
|
|
erxT3Atm4Ioa ERX 4 port T3 ATM IOA
|
|
erxCOc12Mm1ApsIoa ERX 1 port channelized OC12 multi-mode APS
|
|
(1+1) IOA
|
|
erxCOc12SmIr1ApsIoa ERX 1 port channelized OC12 single-mode
|
|
intermediate-reach APS (1+1) IOA
|
|
erxCOc12SmLr1ApsIoa ERX 1 port channelized OC12 single-mode
|
|
long-reach APS (1+1) IOA
|
|
erxOc12Mm1ApsIoa ERX 1 port OC12 multi-mode APS (1+1) IOA
|
|
erxOc12SmIr1ApsIoa ERX 1 port OC12 single-mode
|
|
intermediate-reach APS (1+1) IOA
|
|
erxOc12SmLr1ApsIoa ERX 1 port OC12 single-mode long-reach APS
|
|
(1+1) IOA
|
|
erxCOc12AtmPosMm1Ioa ERX 1 port channelized OC12 multi-mode
|
|
ATM/POS IOA
|
|
erxCOc12AtmPosSmIr1Ioa ERX 1 port channelized OC12 single-mode
|
|
intermediate-reach ATM/POS IOA
|
|
erxCOc12AtmPosSmLr1Ioa ERX 1 port channelized OC12 single-mode
|
|
long-reach ATM/POS IOA
|
|
erxCOc12AtmPosMm1ApsIoa ERX 1 port channelized OC12 multi-mode
|
|
ATM/POS APS (1+1) IOA
|
|
erxCOc12AtmPosSmIr1ApsIoa ERX 1 port channelized OC12 single-mode
|
|
intermediate-reach ATM/POS APS (1+1) IOA
|
|
erxCOc12AtmPosSmLr1ApsIoa ERX 1 port channelized OC12 single-mode
|
|
long-reach ATM/POS APS (1+1) IOA
|
|
erxT1E1RedundantIoa ERX T1/E1 redundant midplane spare IOA
|
|
erxT3E3RedundantIoa ERX T3/E3 redundant midplane spare IOA
|
|
erxCt3RedundantIoa ERX channelized T3 redundant midplane
|
|
spare IOA
|
|
erxOcxRedundantIoa ERX OC3/OC12 redundant midplane spare IOA
|
|
erxCOcxRedundantIoa ERX channelized OC3/OC12 redundant
|
|
midplane spare IOA
|
|
erxOc3Mm4ApsIoa ERX 4 port OC3 multi-mode APS (1+1) IOA
|
|
erxOc3SmIr4ApsIoa ERX 4 port OC3 single-mode
|
|
intermediate-reach APS (1+1) IOA
|
|
erxOc3SmLr4ApsIoa ERX 4 port OC3 single-mode long-reach APS
|
|
(1+1) IOA
|
|
erxOc48Ioa ERX 1 port OC48/STM16 IOA
|
|
erxOc3Atm2Ge1Ioa ERX 2 port OC3 ATM 1 port GE IOA
|
|
erxOc3Atm2Pos2Ioa ERX 2 port OC3 ATM 2 port OC3 POS IOA
|
|
erxGe2Ioa ERX 2 port Gigabit Ethernet IOA
|
|
erxFe8FxIoa ERX 8 port 100 Fast Ethernet SFP IOA
|
|
erxGe8Ioa ERX 8 port Gigabit Ethernet IOA
|
|
ES2 primary modules:
|
|
e320Srp100 ES2 100Gb System Route Processor with integrated
|
|
fabric slice
|
|
e320Sfm100 ES2 100Gb Switch Fabric Slice
|
|
es2Lm4 ES2 4Gb (series 1) Line Module(LM).
|
|
es2Lm10Uplink ES2 10Gb (series 2) Uplink Line Module(LM).
|
|
es2Lm10 ES2 10Gb (series 3) Line Module(LM).
|
|
e320Srp320 ES2 320Gb System Route Processor with integrated
|
|
fabric slice
|
|
e320Sfm320 ES2 320Gb Switch Fabric Slice
|
|
es2Lm10s ES2 10Gb (series 4) Line Module(LM).
|
|
ES2 I/O adapter (IOA) modules:
|
|
e320SrpIoa ES2 system resource processor IOA
|
|
es2Ge4S1Ioa ES2 4 port Gigabit Ethernet S1 IOA
|
|
es2Oc48Stm16PosS1Ioa ES2 OC48/STM16 POS S1 IOA
|
|
es2ServiceS1Ioa ES2 Service S1 IOA
|
|
es2Oc3Stm1x8AtmS1Ioa ES2 OC3/STM1-8 ATM S1 IOA
|
|
es2RedundancyS1Ioa ES2 Redundancy S1 IOA
|
|
es2Oc12Stm4x2PosS1Ioa ES2 OC12/STM4-2 POS S1 IOA
|
|
es2Oc12Stm4x2AtmS1Ioa ES2 OC12/STM4-2 ATM S1 IOA
|
|
es2dash10GeS1Ioa ES2 10GE-1 SR S1 IOA
|
|
es2Ge8S1Ioa ES2 8 port Gigabit Ethernet S1 IOA
|
|
es2dash10GePrS2Ioa ES2 10GE-1 Port Redundancy S2 IOA
|
|
es2Ge20S2Ioa ES2 20 port Gigabit Ethernet S2 IOA
|
|
ES2 primary modules for E120:
|
|
e120Srp120 ES2 120Gb System Route Processor with integrated
|
|
fabric slice
|
|
e120Sfm120 ES2 120Gb Switch Fabric Slice"
|
|
|
|
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
-- ERX primary module types
|
|
erxSrp(1),
|
|
erxCt3(2),
|
|
erxOc3(3),
|
|
erxUt3Atm(4),
|
|
erxUt3Frame(5),
|
|
erxUe3Atm(6),
|
|
erxUe3Frame(7),
|
|
erxCe1(8),
|
|
erxCt1(9),
|
|
erxDpfe(10),
|
|
erxOc12Pos(11),
|
|
erxOc12Atm(12),
|
|
erxOc3Pos(13),
|
|
erxOc3Atm(14),
|
|
erxGe(15),
|
|
erxFe8(16),
|
|
erxOc3oc12Pos(17),
|
|
erxOc3oc12Atm(18),
|
|
erxCoc3oc12(19),
|
|
erxCoc3(20),
|
|
erxCoc12(21),
|
|
erxOc12Server(22),
|
|
erxHssi(23),
|
|
erxGeFe(24),
|
|
erxCt3P12(25),
|
|
erxV35(26),
|
|
erxUt3f12(27),
|
|
erxUe3f12(28),
|
|
erxCoc12F3(29),
|
|
erxCoc3F3(30),
|
|
erxCocxF3(31),
|
|
erxVts(32),
|
|
erxOc48(33),
|
|
erxUt3Atm4(34),
|
|
erxHybrid(35),
|
|
erxOc3AtmGe(36),
|
|
erxOc3AtmPos(37),
|
|
erxGe2(38),
|
|
erxGeHde(39),
|
|
-- ERX I/O adapter (IOA) module types
|
|
erxSrpIoa(1024),
|
|
erxCt1Ioa(1025),
|
|
erxCe1Ioa(1026),
|
|
erxCe1TIoa(1027),
|
|
erxCt3Ioa(1028),
|
|
erxE3Ioa(1029),
|
|
erxOc3Mm2Ioa(1030),
|
|
erxOc3Sm2Ioa(1031),
|
|
erxOc3Mm4Ioa(1032),
|
|
erxOc3SmIr4Ioa(1033),
|
|
erxOc3SmLr4Ioa(1034),
|
|
erxCOc3Mm4Ioa(1035),
|
|
erxCOc3SmIr4Ioa(1036),
|
|
erxCOc3SmLr4Ioa(1037),
|
|
erxOc12Mm1Ioa(1038),
|
|
erxOc12SmIr1Ioa(1039),
|
|
erxOc12SmLr1Ioa(1040),
|
|
erxCOc12Mm1Ioa(1041),
|
|
erxCOc12SmIr1Ioa(1042),
|
|
erxCOc12SmLr1Ioa(1043),
|
|
erxFe2Ioa(1044),
|
|
erxFe8Ioa(1045),
|
|
erxGeMm1Ioa(1046),
|
|
erxGeSm1Ioa(1047),
|
|
erxHssiIoa(1048),
|
|
erxCt3P12Ioa(1049),
|
|
erxV35Ioa(1050),
|
|
erxGeSfpIoa(1051),
|
|
erxUe3P12Ioa(1052),
|
|
erxT3Atm4Ioa(1053),
|
|
erxCOc12Mm1ApsIoa(1054),
|
|
erxCOc12SmIr1ApsIoa(1055),
|
|
erxCOc12SmLr1ApsIoa(1056),
|
|
erxOc12Mm1ApsIoa(1057),
|
|
erxOc12SmIr1ApsIoa(1058),
|
|
erxOc12SmLr1ApsIoa(1059),
|
|
erxCOc12AtmPosMm1Ioa(1060),
|
|
erxCOc12AtmPosSmIr1Ioa(1061),
|
|
erxCOc12AtmPosSmLr1Ioa(1062),
|
|
erxCOc12AtmPosMm1ApsIoa(1063),
|
|
erxCOc12AtmPosSmIr1ApsIoa(1064),
|
|
erxCOc12AtmPosSmLr1ApsIoa(1065),
|
|
erxT1E1RedundantIoa(1066),
|
|
erxT3E3RedundantIoa(1067),
|
|
erxCt3RedundantIoa(1068),
|
|
erxOcxRedundantIoa(1069),
|
|
erxCOcxRedundantIoa(1070),
|
|
erxOc3Mm4ApsIoa(1071),
|
|
erxOc3SmIr4ApsIoa(1072),
|
|
erxOc3SmLr4ApsIoa(1073),
|
|
erxOc48Ioa(1074),
|
|
erxOc3Atm2Ge1Ioa(1075),
|
|
erxOc3Atm2Pos2Ioa(1076),
|
|
erxGe2Ioa(1077),
|
|
erxFe8FxIoa(1078),
|
|
erxGe8Ioa(1079),
|
|
-- ES2 primary module types
|
|
e320Srp100(2048),
|
|
e320Sfm100(2049),
|
|
es2Lm4(2050),
|
|
es2Lm10Uplink(2051),
|
|
es2Lm10(2052),
|
|
e320Srp320(2053),
|
|
e320Sfm320(2054),
|
|
es2Lm10s(2055),
|
|
-- ES2 I/O adapter (IOA) module types
|
|
e320SrpIoa(3072),
|
|
es2Ge4S1Ioa(3073),
|
|
es2Oc48Stm16PosS1Ioa(3074),
|
|
es2ServiceS1Ioa(3075),
|
|
es2Oc3Stm1x8AtmS1Ioa(3076),
|
|
es2RedundancyS1Ioa(3077),
|
|
es2Oc12Stm4x2PosS1Ioa(3078),
|
|
es2Oc12Stm4x2AtmS1Ioa(3079),
|
|
es2dash10GeS1Ioa(3080),
|
|
es2Ge8S1Ioa(3081),
|
|
es2dash10GePrS2Ioa(3082),
|
|
es2Ge20S2Ioa(3083) ,
|
|
-- ES2 primary module types for E120
|
|
e120Srp120(4096),
|
|
e120Sfm120(4097) }
|
|
|
|
JuniSystemSlotLevel ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The relative position of a module or sub-module 'container' within a
|
|
slot. The upper limit of valid values is juniSystemMaxModulesPerSlot.
|
|
A module or sub-module in the lowest numbered level for a particular
|
|
slot is considered to be the 'primary' module for that slot.
|
|
|
|
For the first generation E-series (ERX) platform family:
|
|
level 1 - SRP or line card module
|
|
level 2 - I/O adapter module
|
|
|
|
For the second generation E-series platform family:
|
|
level 1 - Forwarding module or SRP sub-module
|
|
level 2 - Switch fabric slice (SFS) sub-module or module
|
|
level 3 - Bay 0 I/O adapter
|
|
level 4 - Bay 1 I/O adapter "
|
|
|
|
SYNTAX Integer32 (1..4)
|
|
|
|
JuniSystemSlotType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of 'container' for holding a module or sub-module found in an
|
|
E-series chassis.
|
|
|
|
The slot type may be for a 'sub-module' where there are multiple logical
|
|
functions on a single hardware module. For example, the second
|
|
generation SRP hardware module (slot 6 or 7 on an E320) contains both a
|
|
System Resource Processor (SRP) sub-module (level 1 position) and a
|
|
Switch Fabric Slice (SFS) sub-module (level 2 position).
|
|
|
|
noSlot The slot does not exist
|
|
ERX system slot types:
|
|
erxSrpSlot ERX switch/route processor module slot
|
|
erxLcmSlot ERX line card module slot
|
|
erxSrpIoaSlot ERX switch/route processor I/O adapter slot
|
|
erxLcIoaSlot ERX line card I/O adapter slot
|
|
Second generation E-series (ES2) system slot types:
|
|
es2SrpSlot ES2 system resource processor sub-module slot
|
|
es2SfsSlot ES2 switch fabric module or sub-module slot
|
|
es2FmSlot ES2 forwarding module slot
|
|
es2SrpIoaSlot ES2 system resource processor I/O adapter slot
|
|
es2FIoaSlot ES2 forwarding I/O adapter slot "
|
|
SYNTAX INTEGER {
|
|
noSlot(0),
|
|
-- ERX system slot types
|
|
erxSrpSlot(1),
|
|
erxLcmSlot(2),
|
|
erxSrpIoaSlot(3),
|
|
erxLcIoaSlot(4),
|
|
-- ES2 system slot types
|
|
es2SrpSlot(16),
|
|
es2SfsSlot(17),
|
|
es2FmSlot(18),
|
|
es2SrpIoaSlot(19),
|
|
es2FIoaSlot(20) }
|
|
|
|
JuniSystemTimingSelector ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system timing selector.
|
|
primary - the primary timing selector
|
|
secondary - the secondary timing selector
|
|
tertiary - the tertiary timing selector
|
|
error - the error in timing selector"
|
|
SYNTAX INTEGER {
|
|
primary(1),
|
|
secondary(2),
|
|
tertiary(3),
|
|
error(4)}
|
|
|
|
JuniSystemLocationType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The location information class that is used to understand the encoding
|
|
of the associated location instance information. An object with this
|
|
syntax is always paired with an object that uses the JuniSystemLocation
|
|
syntax.
|
|
system - all resources on the system
|
|
slot - all resources associated with a particular slot "
|
|
SYNTAX INTEGER {
|
|
system(1),
|
|
slot(2) }
|
|
|
|
JuniSystemLocation ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The location instance information that is encoded according to the
|
|
rules for the associated location information class. An object with
|
|
this syntax is always paired with an object that uses the
|
|
JuniSystemLocationType syntax.
|
|
system - a zero length string: { ''H }
|
|
slot - a single octet (see juniSystemSlotNumber) "
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
|
|
JuniSystemTaskName ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "100a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the task. Represents textual information taken from the
|
|
NVT ASCII character set. The character repertoire of the string is
|
|
restricted to printable, non-whitespace characters (codes 33 through
|
|
126)."
|
|
REFERENCE
|
|
"RFC 854: NVT ASCII character set."
|
|
SYNTAX OCTET STRING (SIZE(1..100))
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- MIB Structure
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemTrap OBJECT IDENTIFIER ::= { juniSystemMIB 0 }
|
|
juniSystemObjects OBJECT IDENTIFIER ::= { juniSystemMIB 1 }
|
|
juniSystemConformance OBJECT IDENTIFIER ::= { juniSystemMIB 2 }
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Managed objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemGeneral OBJECT IDENTIFIER ::= { juniSystemObjects 1 }
|
|
juniSystemSubsystem OBJECT IDENTIFIER ::= { juniSystemObjects 2 }
|
|
juniSystemModule OBJECT IDENTIFIER ::= { juniSystemObjects 3 }
|
|
juniSystemPort OBJECT IDENTIFIER ::= { juniSystemObjects 4 }
|
|
juniSystemTiming OBJECT IDENTIFIER ::= { juniSystemObjects 5 }
|
|
juniSystemFabric OBJECT IDENTIFIER ::= { juniSystemObjects 6 }
|
|
juniSystemNvs OBJECT IDENTIFIER ::= { juniSystemObjects 7 }
|
|
juniSystemPower OBJECT IDENTIFIER ::= { juniSystemObjects 8 }
|
|
juniSystemTemperature OBJECT IDENTIFIER ::= { juniSystemObjects 9 }
|
|
juniSystemUtilization OBJECT IDENTIFIER ::= { juniSystemObjects 10 }
|
|
juniSystemIssu OBJECT IDENTIFIER ::= { juniSystemObjects 11 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- General operational software system objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version identification of currently executing system-wide operational
|
|
software."
|
|
::= { juniSystemGeneral 1 }
|
|
|
|
juniSystemSwBuildDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Build date of currently executing system-wide operational software
|
|
version."
|
|
::= { juniSystemGeneral 2 }
|
|
|
|
juniSystemMemUtilPct OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Percentage of memory utilization on the primary system processor. A
|
|
value of -1 indicates the utilization is unknown."
|
|
::= { juniSystemGeneral 3 }
|
|
|
|
juniSystemMemCapacity OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total memory capacity in bytes of the primary system processor. If
|
|
the memory capacity is greater than 2147483647, a -1 value is returned,
|
|
and the actual memory capacity (in number of bytes divided by 1024) is
|
|
returned in juniSystemMemKBytesCapacity."
|
|
::= { juniSystemGeneral 4 }
|
|
|
|
juniSystemMemKBytesCapacity OBJECT-TYPE
|
|
SYNTAX KBytes
|
|
UNITS "KBytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total memory capacity in kilo-bytes (1024 bytes) of the primary
|
|
system processor."
|
|
::= { juniSystemGeneral 23 }
|
|
|
|
juniSystemHighMemUtilThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (1..99)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of memory utilization in the primary system processor, where,
|
|
if reached for the first time after a high memory threshold reset, a
|
|
high memory utilization event notification will be sent to the
|
|
management entity on this system. A high memory threshold reset occurs
|
|
when the system is initialized (booted) or the memory utilization falls
|
|
below the value in juniSystemAbatedMemUtilThreshold.
|
|
|
|
The value of this object must always be greater than the value of
|
|
juniSystemAbatedMemUtilThreshold."
|
|
DEFVAL { 85 }
|
|
::= { juniSystemGeneral 5 }
|
|
|
|
juniSystemAbatedMemUtilThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..98)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of memory utilization in the primary system processor that is
|
|
used to determine when to send an abated memory utilization event
|
|
notification to the management entity on this system. The abated memory
|
|
utilization event occurs if a high memory threshold reset has not
|
|
occurred since the last high memory threshold event, and then the memory
|
|
utilization falls to or below the value of this object. The abated
|
|
memory utilization event then triggers a high memory threshold reset.
|
|
|
|
The value of this object must always be less than the value of
|
|
juniSystemHighMemUtilThreshold."
|
|
DEFVAL { 75 }
|
|
::= { juniSystemGeneral 6 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- General software system reload configuration objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemBootConfigControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
file(0),
|
|
fileOnce(1),
|
|
factoryDefaults(2),
|
|
runningConfiguration(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System boot configuration control:
|
|
file - On a system reboot use the configuration
|
|
settings specified by the
|
|
juniSystemBootConfigFile. The
|
|
juniSystemBootConfigControl and
|
|
juniSystemBootConfigFile must be specified
|
|
together in the same set request PDU.
|
|
fileOnce - On the next system reboot use the
|
|
configuration settings specified by the
|
|
juniSystemBootConfigFile. Do not continue
|
|
to use this file after using it once; on
|
|
subsequent reboots use the running
|
|
configuration. The
|
|
juniSystemBootConfigControl and
|
|
juniSystemBootConfigFile must be specified
|
|
together in the same set request PDU.
|
|
factoryDefaults - On the next system reboot use the factory
|
|
default settings. On subsequent reboots use
|
|
the running configuration.
|
|
runningConfiguration - On a system reboot use the current
|
|
configuration settings."
|
|
::= { juniSystemGeneral 7 }
|
|
|
|
juniSystemBootBackupConfigControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
file(0),
|
|
factoryDefaults(1),
|
|
none(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System boot backup configuration control is used to determine the
|
|
configuration to be used when the boot logic chooses backup mode:
|
|
file - On a system reboot in backup mode use the
|
|
configuration settings specified by the
|
|
juniSystemBootBackupConfigFile. If this option
|
|
is specified, juniSystemBootBackupConfigFile,
|
|
juniSystemBootBackupReleaseFile and this object
|
|
must be specified together in the same set
|
|
request PDU.
|
|
factoryDefaults - On a system reboot in backup mode use the
|
|
factory default configuration settings. If this
|
|
option is specified,
|
|
juniSystemBootBackupReleaseFile and this object
|
|
must be specified together in the same set
|
|
request PDU.
|
|
none - Disallow the boot logic from using the backup
|
|
release file and configuration (i.e., disable
|
|
backup mode)."
|
|
::= { juniSystemGeneral 8 }
|
|
|
|
juniSystemBootForceBackupControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System boot force backup control:
|
|
off - On the next system reboot do not force the boot logic to
|
|
choose backup mode.
|
|
on - On the next system reboot force the boot logic to choose
|
|
backup mode.
|
|
|
|
Attempting to set this object to on(1) while the
|
|
juniSystemBootBackupConfigControl is set to none(2) will result in an
|
|
error."
|
|
::= { juniSystemGeneral 9 }
|
|
|
|
juniSystemBootAutoRevertControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
default(0),
|
|
never(1),
|
|
set(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system boot auto-revert control is used to determine when the boot
|
|
logic should choose backup mode based of the reboot history:
|
|
default - Use the default auto-revert tolerances: 3 reboots in 30
|
|
minutes.
|
|
never - Never auto-revert to backup mode.
|
|
set - Use the auto-revert tolerances specified by
|
|
juniSystemBootAutoRevertCountTolerance and
|
|
juniSystemBootAutoRevertTimeTolerance, which must be
|
|
specified in the same PDU as this object when this value
|
|
is specified."
|
|
::= { juniSystemGeneral 10 }
|
|
|
|
juniSystemBootAutoRevertCountTolerance OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..4294967294)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The auto-revert reboot count tolerance, used in conjunction with the
|
|
value of juniSystemBootAutoRevertTimeTolerance when
|
|
juniSystemBootAutoRevertControl is set to set(2) in the same PDU. For
|
|
example, if this object is set to 4 and
|
|
juniSystemBootAutoRevertTimeTolerance is set to 1200, then the boot
|
|
logic will choose backup mode if 4 system reboots occur within 20
|
|
minutes. This object cannot be set to zero, but may contain a zero
|
|
value when juniSystemBootAutoRevertControl is set to never(1)."
|
|
::= { juniSystemGeneral 11 }
|
|
|
|
juniSystemBootAutoRevertTimeTolerance OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..4294967294)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The auto-revert reboot time tolerance, used in conjunction with the
|
|
value of juniSystemBootAutoRevertCountTolerance when
|
|
juniSystemBootAutoRevertControl is set to set(2) in the same PDU. This
|
|
object cannot be set to zero, but will contain a zero value when
|
|
juniSystemBootAutoRevertControl is set to never(1)."
|
|
::= { juniSystemGeneral 12 }
|
|
|
|
juniSystemBootReleaseFile OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system-wide boot release file name, with extension '.rel'. On a
|
|
set operation, if there is no file found with the name specified, then
|
|
an error is returned."
|
|
::= { juniSystemGeneral 13 }
|
|
|
|
juniSystemBootConfigFile OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system-wide boot configuration file name. This object and the
|
|
juniSystemBootConfigControl object set to file(0) or fileOnce(1) must be
|
|
specified together in the same set request PDU. If
|
|
juniSystemBootConfigControl is file(0), only file names with extension
|
|
'.cnf' are allowed. If juniSystemBootConfigControl is fileOnce(1), only
|
|
file names with extensions '.cnf' or '.scr' are allowed. On a set
|
|
operation, if the extension is not appropriate or there is no file found
|
|
with the name specified, then an error is returned. If
|
|
juniSystemBootConfigControl is not set to file(0) or fileOnce(1) then a
|
|
get operation for this object will return a zero-length string."
|
|
DEFVAL { "" }
|
|
::= { juniSystemGeneral 14 }
|
|
|
|
juniSystemBootBackupReleaseFile OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system-wide backup boot release file name, with extension '.rel'.
|
|
A zero-length string indicates that there is no backup release file so
|
|
the primary release file (juniSystemBootReleaseFile) will be used. On a
|
|
set operation if there is no file found with the name specified, then an
|
|
error is returned. The juniSystemBootBackupConfigControl object with a
|
|
valid value other than none(2) must be specified together with this
|
|
object in the same set request PDU, and if the
|
|
juniSystemBootBackupConfigControl is set to file(0) then a valid
|
|
juniSystemBootBackupConfigFile must also be included in the set request
|
|
PDU."
|
|
DEFVAL { "" }
|
|
::= { juniSystemGeneral 15 }
|
|
|
|
juniSystemBootBackupConfigFile OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system-wide backup boot configuration file name, with extension
|
|
'.cnf'. The juniSystemBootBackupReleaseFile object, the
|
|
juniSystemBootBackupConfigControl object set to file(0), and this object
|
|
must be specified together in the same set request PDU. On a set
|
|
operation, if there is no file found with the name specified, then an
|
|
error is returned. If juniSystemBootBackupConfigControl is not set to
|
|
file(0) then a get operation for this object will return a zero-length
|
|
string."
|
|
DEFVAL { "" }
|
|
::= { juniSystemGeneral 16 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- System-wide module redundancy control objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemRedundancyRevertControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
immediate(1),
|
|
timeOfDay(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Global control for reverting primary modules back from their active
|
|
redundant spare modules:
|
|
off - Disable global reverts of redundant modules.
|
|
immediate - All redundant module pairs are to revert as soon as the
|
|
primary module is ready to enter the online state.
|
|
timeOfDay - All redundant module pairs are to revert at the time
|
|
specified by juniSystemRevertTimeOfDay, relative to
|
|
midnight based on the system clock time. This object
|
|
must be set concurrently with juniSystemRevertTimeOfDay
|
|
when this value is specified.
|
|
|
|
Note that this only applies to modules that have
|
|
juniSystemModuleRedundancySupport set to true(1)."
|
|
::= { juniSystemGeneral 17 }
|
|
|
|
juniSystemRedundancyRevertTimeOfDay OBJECT-TYPE
|
|
SYNTAX Integer32 (0..86399)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of seconds past midnight local time on any given day at
|
|
which time redundant slot reverts are allowed to occur. This object
|
|
must be set concurrently with juniSystemRevertControl { timeOfDay }."
|
|
::= { juniSystemGeneral 18 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Subsystem objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemSubsystemTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemSubsystemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of subsystems. A subsystem supports a 'family' of module types;
|
|
that is, each module type is supported by a particular software
|
|
subsystem. For example, the ERX channelized T1 line card (CT1-FULL) is
|
|
supported by the 'ct1' subsystem."
|
|
::= { juniSystemSubsystem 1 }
|
|
|
|
juniSystemSubsystemEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemSubsystemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry containing information pertaining to a subsystem.
|
|
Subsystem information takes precedence over system-wide information, but
|
|
not over individual module information."
|
|
INDEX { juniSystemSubsystemIndex }
|
|
::= { juniSystemSubsystemTable 1 }
|
|
|
|
JuniSystemSubsystemEntry ::= SEQUENCE {
|
|
juniSystemSubsystemIndex Integer32,
|
|
juniSystemSubsystemName DisplayString,
|
|
juniSystemSubsystemBootReleaseFile DisplayString,
|
|
juniSystemSubsystemBootBackupReleaseFile DisplayString }
|
|
|
|
juniSystemSubsystemIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Arbitrary subsystem identification number."
|
|
::= { juniSystemSubsystemEntry 1 }
|
|
|
|
juniSystemSubsystemName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the subsystem."
|
|
::= { juniSystemSubsystemEntry 2 }
|
|
|
|
juniSystemSubsystemBootReleaseFile OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The boot release file name for this subsystem, with extension '.rel'.
|
|
If a file name is specified (a non-zero-length string), then this
|
|
release file takes precedence over the system-wide boot release file
|
|
(juniSystemBootReleaseFile) just for modules of the type specified by
|
|
the subsystem name. On a set operation, if there is no file that
|
|
matches the name specified, then an inconsistentValue error will be
|
|
returned. Setting this object to a zero-length string deconfigures the
|
|
subsystem-specific backup release file."
|
|
DEFVAL { "" }
|
|
::= { juniSystemSubsystemEntry 3 }
|
|
|
|
juniSystemSubsystemBootBackupReleaseFile OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The backup boot release file name for this subsystem, with extension
|
|
'.rel'. If a file name is specified (a non-zero-length string), then
|
|
this release file takes precedence over the system-wide boot backup
|
|
release file (juniSystemBootBackupReleaseFile) just for modules of the
|
|
type specified by the subsystem name. This object cannot be set unless
|
|
the system has a backup file, which means that
|
|
juniSystemBootBackupReleaseFile must contain a file name (a
|
|
non-zero-length string). On a set operation, if there is no file that
|
|
matches the name specified, then an inconsistentValue error will be
|
|
returned. Setting this object to a zero-length string deconfigures the
|
|
subsystem-specific backup release file."
|
|
DEFVAL { "" }
|
|
::= { juniSystemSubsystemEntry 4 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Module Slot objects
|
|
-- A slot represents a position in a chassis that contains one or more phisical
|
|
-- modules (printed circuit boards) and/or sub-modules that operate together as
|
|
-- a functional unit.
|
|
-- A sub-module is a functionally independent portion of a physical module.
|
|
-- One physical module may contain more than one sub-module.
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemMaxSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest number assigned to a slot in the system. In a particular
|
|
hardware model, module slots have fixed numbers assigned to them, even
|
|
though in some instances there may be no actual slots associated with a
|
|
particular number. In all cases there is a maximum slot number that
|
|
will never be exceeded:
|
|
2 for ERX-3xx models
|
|
6 for ERX-7xx models
|
|
13 for ERX-14xx models
|
|
16 for E320 models
|
|
|
|
Note that slot numbers are zero-based."
|
|
::= { juniSystemModule 1 }
|
|
|
|
juniSystemMaxModulesPerSlot OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of modules and sub-modules (different levels) that
|
|
can be associated with a slot number in the system. This value is
|
|
constant for a particular hardware platform family. The number of
|
|
levels is 2 for a first generation E-series (ERX) platform and is 4 for
|
|
a second generation E-series platform.
|
|
|
|
For the first generation E-series (ERX) platform family:
|
|
level 1 - SRP or line card module
|
|
level 2 - I/O adapter module
|
|
|
|
For the second generation E-series platform family:
|
|
level 1 - Forwarding module or SRP sub-module
|
|
level 2 - Switch fabric slice (SFS) sub-module or module
|
|
level 3 - Bay 0 I/O adapter
|
|
level 4 - Bay 1 I/O adapter "
|
|
::= { juniSystemModule 2 }
|
|
|
|
juniSystemSlotTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of system module slot physical container configuration
|
|
information."
|
|
::= { juniSystemModule 3 }
|
|
|
|
juniSystemSlotEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry describing the physical status of a system module slot
|
|
container, which is designated by its slot and level positions. There
|
|
is an entry in this table for all index pairs from { 0, 1 } to the
|
|
maximum for each index, { juniSystemMaxSlotNumber,
|
|
juniSystemMaxModulesPerSlot }, even if there is no corresponding module
|
|
slot container in the system. A request for an index value outside this
|
|
range will result in a 'no such' response."
|
|
INDEX { juniSystemSlotNumber,
|
|
juniSystemSlotLevel }
|
|
::= { juniSystemSlotTable 1 }
|
|
|
|
JuniSystemSlotEntry ::= SEQUENCE {
|
|
juniSystemSlotNumber Integer32,
|
|
juniSystemSlotLevel JuniSystemSlotLevel,
|
|
juniSystemSlotStatus INTEGER,
|
|
juniSystemSlotType JuniSystemSlotType }
|
|
|
|
juniSystemSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot number. The actual upper limit of valid values is
|
|
juniSystemMaxSlotNumber. Note that slot numbers are zero-based."
|
|
::= { juniSystemSlotEntry 1 }
|
|
|
|
juniSystemSlotLevel OBJECT-TYPE
|
|
SYNTAX JuniSystemSlotLevel
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The relative position of a module or sub-module 'container' within a
|
|
slot."
|
|
::= { juniSystemSlotEntry 2 }
|
|
|
|
juniSystemSlotStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
noSlotContainer(1),
|
|
empty(2),
|
|
moduleNotPresent(3),
|
|
modulePresent(4) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the module slot container.
|
|
unknown - The existence of a container cannot be
|
|
determined
|
|
noSlotContainer - The physical container does not exist
|
|
empty - No module is present and no configuration
|
|
information is available for this container
|
|
moduleNotPresent - A module is configured but it is not currently
|
|
in its container
|
|
modulePresent - A module is inserted in the container "
|
|
::= { juniSystemSlotEntry 3 }
|
|
|
|
juniSystemSlotType OBJECT-TYPE
|
|
SYNTAX JuniSystemSlotType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The category of modules that can be configured for the container."
|
|
::= { juniSystemSlotEntry 4 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Module Status objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemModuleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemModuleEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of system module and sub-module information. In this table, a
|
|
module refers to a physical module (board) or a sub-module.
|
|
|
|
A physical board may contain a single module or multiple sub-modules.
|
|
For example, an ERX line card is a single module and appears as single
|
|
entry in this table. An I/O adapter is a module that doesn't provide
|
|
any operaitonal state information and it also appears as a single entry
|
|
in this table. A second generation E-series SRP/SFS hardware module
|
|
contains two sub-modules, each with its own operational state
|
|
information: a System Resource Processor (SRP) sub-module and a Switch
|
|
Fabric Slice (SFS) sub-module, which appear as two separate entries in
|
|
this table, one for each sub-module."
|
|
::= { juniSystemModule 4 }
|
|
|
|
juniSystemModuleEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemModuleEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry that provides information about a specific system module
|
|
or sub-module in a particular module location. There are only entries
|
|
in this table for module locations that report a juniSystemSlotStatus of
|
|
moduleNotPresent(3) or modulePresent(4)."
|
|
INDEX { juniSystemSlotNumber,
|
|
juniSystemSlotLevel }
|
|
::= { juniSystemModuleTable 1 }
|
|
|
|
JuniSystemModuleEntry ::= SEQUENCE {
|
|
juniSystemModuleOperStatus INTEGER,
|
|
juniSystemModuleDisableReason INTEGER,
|
|
juniSystemModuleLastChange TimeTicks,
|
|
juniSystemModuleCurrentType JuniSystemModuleType,
|
|
juniSystemModuleExpectedType JuniSystemModuleType,
|
|
juniSystemModuleDescr DisplayString,
|
|
juniSystemModuleSlotSpan Integer32,
|
|
juniSystemModulePortCount Integer32,
|
|
juniSystemModuleSerialNumber DisplayString,
|
|
juniSystemModuleAssemblyPartNumber DisplayString,
|
|
juniSystemModuleAssemblyRev DisplayString,
|
|
juniSystemModulePhysicalIndex PhysicalIndex,
|
|
juniSystemModuleSoftwareSupport TruthValue,
|
|
juniSystemModuleRedundancySupport TruthValue,
|
|
juniSystemModuleLevelSpan Integer32 }
|
|
|
|
juniSystemModuleOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
notPresent(1),
|
|
disabled(2),
|
|
hardwareError(3),
|
|
booting(4),
|
|
initializing(5),
|
|
online(6),
|
|
standby(7),
|
|
inactive(8),
|
|
notResponding(9) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operational status of the module (or sub-module):
|
|
unknown - The status of the module cannot be determined
|
|
notPresent - No hardware is currently present but there was a
|
|
module previously configured in this position (see
|
|
juniSystemModuleExpectedType);
|
|
juniSystemModuleCurrentType is unknown(0)
|
|
disabled - Disable for the reason specified in
|
|
juniSystemModuleDisableReason
|
|
hardwareError - Not operational due to a hardware failure
|
|
booting - In the process of booting
|
|
initializing - In the process of initialing
|
|
online - Fully operational
|
|
standby - In redundant standby mode
|
|
inactive - In redundant inactive mode
|
|
notResponding - Unable to communicate with the rest of the system "
|
|
::= { juniSystemModuleEntry 1 }
|
|
|
|
juniSystemModuleDisableReason OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
unknown(1),
|
|
assessing(2),
|
|
admin(3),
|
|
typeMismatch(4),
|
|
fabricLimit(5),
|
|
imageError(6) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the condition causing the module (or sub-module) to be
|
|
disabled:
|
|
none - Value when the module is not disabled
|
|
unknown - Unknown reason for disablement
|
|
assessing - The module content is being assessed (transient
|
|
initialization state)
|
|
admin - The module is administratively disabled
|
|
typeMismatch - The current module personality conflicts with
|
|
configuration associated with a different (expected)
|
|
module personality that previously occupied the slot
|
|
fabricLimit - Module resource requirements exceed available fabric
|
|
capacity
|
|
imageError - Software image for the module is missing or invalid"
|
|
::= { juniSystemModuleEntry 2 }
|
|
|
|
juniSystemModuleLastChange OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the value of juniSystemModuleOperStatus
|
|
last changed."
|
|
::= { juniSystemModuleEntry 3 }
|
|
|
|
juniSystemModuleCurrentType OBJECT-TYPE
|
|
SYNTAX JuniSystemModuleType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The personality of this module based on the combination of modules that
|
|
are currently inserted in the slot. This could be different from the
|
|
personality reported in juniSystemModuleExpectedType, in which case it
|
|
may be necessary to set juniSystemModuleControl for the module in the
|
|
primary level to 'flush' before the set of modules in this slot can be
|
|
made operational."
|
|
::= { juniSystemModuleEntry 4 }
|
|
|
|
juniSystemModuleExpectedType OBJECT-TYPE
|
|
SYNTAX JuniSystemModuleType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The personality for this module position based on the combination of
|
|
modules that were inserted in this slot when it was last configured.
|
|
The value of this object will be different than the value of
|
|
juniSystemModuleCurrentType when the value of juniSystemModuleOperStatus
|
|
is disabled(2) and the value of juniSystemModuleDisableReason is
|
|
typeMismatch(4). After one or more modules is removed from a slot,
|
|
configuration information associated with the slot (its 'personality')
|
|
may persist, inhibiting the operation of a different combination of
|
|
modules in the slot (when new modules are inserted) until
|
|
juniSystemModuleControl for the slot's primary module is set to
|
|
flush(1)."
|
|
::= { juniSystemModuleEntry 5 }
|
|
|
|
juniSystemModuleDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual description of the expected module in this slot."
|
|
::= { juniSystemModuleEntry 6 }
|
|
|
|
juniSystemModuleSlotSpan OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of slot positions that the expected module spans. Most
|
|
modules are only one slot wide, but some require extra space or
|
|
backplane resources. These modules are identified as being in the lower
|
|
numbered slot and spanning across the higher numbered slot(s)."
|
|
::= { juniSystemModuleEntry 7 }
|
|
|
|
juniSystemModulePortCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of physical ports supported by the expected module type in
|
|
this slot."
|
|
::= { juniSystemModuleEntry 8 }
|
|
|
|
juniSystemModuleSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The serial number of the expected module in this slot. The serial
|
|
number of the current module may be found in this module's
|
|
entPhysicalSerialNum. A serial number is for a hardware board, so if
|
|
there is more than one sub-module on a board, their serial numbers will
|
|
all be the same."
|
|
DEFVAL { "" }
|
|
::= { juniSystemModuleEntry 9 }
|
|
|
|
juniSystemModuleAssemblyPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The part number of the expected module in this slot. The part number
|
|
of the current module may be found in this module's
|
|
entPhysicalModelName. A part number is for a hardware board, so if
|
|
there is more than one sub-module on a board, their part numbers will
|
|
all be the same."
|
|
DEFVAL { "" }
|
|
::= { juniSystemModuleEntry 10 }
|
|
|
|
juniSystemModuleAssemblyRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..3))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The revision level of the expected module in this slot. The revision
|
|
level of the current module may be found in this module's
|
|
entPhysicalHardwareRev. A revision level is for a hardware board, so if
|
|
there is more than one sub-module on a board, their revision levels will
|
|
all be the same."
|
|
DEFVAL { "" }
|
|
::= { juniSystemModuleEntry 11 }
|
|
|
|
juniSystemModulePhysicalIndex OBJECT-TYPE
|
|
SYNTAX PhysicalIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entPhysicalIndex value assigned to the module. The
|
|
ENTITY-MIB.entPhysicalTable contains additional information about this
|
|
module that can be retrieved using this index. An entPhysicalIndex is
|
|
for a hardware board, so if there is more than one sub-module on a
|
|
board, their entPhysicalIndex values will all be the same."
|
|
::= { juniSystemModuleEntry 12 }
|
|
|
|
juniSystemModuleSoftwareSupport OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indicator as to whether this module or sub-module has operational
|
|
state information that can be managed. If the value of this object is
|
|
true(1), then there is an entry for this module or sub-module in the
|
|
juniSystemModuleSoftwareTable."
|
|
::= { juniSystemModuleEntry 13 }
|
|
|
|
juniSystemModuleRedundancySupport OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indicator as to whether this module or sub-module is part of a
|
|
redundancy group. If the value of this object is true(1), then there is
|
|
an entry for this module or sub-module in the
|
|
juniSystemModuleRedundancyTable."
|
|
::= { juniSystemModuleEntry 14 }
|
|
|
|
juniSystemModuleLevelSpan OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of level positions that the expected module spans. Most
|
|
modules are only one level 'high', but some require extra space or
|
|
backplane resources. These modules are identified as being in the lower
|
|
numbered level and spanning across the higher numbered level(s)."
|
|
::= { juniSystemModuleEntry 15 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Module Software objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemModuleSoftwareTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemModuleSoftwareEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of system module software information. This includes the
|
|
version of the software running on the particular module, the running
|
|
software's use of the modules resources and the modules operational
|
|
state.
|
|
|
|
Some module types don't contain loadable software (they execute
|
|
'firmware') but include support for some of the objects in this table.
|
|
For example, the E320 SFS (es2Sfs) modules only support
|
|
juniSystemModuleAdminStatus and juniSystemModuleControl. Appropriate
|
|
'default' values are returned for the other objects.
|
|
|
|
Some module types don't contain any software related information (e.g.,
|
|
ERX I/O adapters do not) in which case their value of
|
|
juniSystemModuleSoftwareSupport will be false and there will not be a
|
|
corresponding entry in this table."
|
|
::= { juniSystemModule 5 }
|
|
|
|
juniSystemModuleSoftwareEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemModuleSoftwareEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry that provides software information about a specific
|
|
system module in a particular slot location."
|
|
INDEX { juniSystemSlotNumber,
|
|
juniSystemSlotLevel }
|
|
::= { juniSystemModuleSoftwareTable 1 }
|
|
|
|
JuniSystemModuleSoftwareEntry ::= SEQUENCE {
|
|
juniSystemModuleSoftwareVersion DisplayString,
|
|
juniSystemModuleCpuUtilPct Integer32,
|
|
juniSystemModuleMemUtilPct Integer32,
|
|
juniSystemModuleAdminStatus JuniEnable,
|
|
juniSystemModuleControl INTEGER,
|
|
juniSystemModuleBootReleaseFile DisplayString,
|
|
juniSystemModuleBootBackupReleaseFile DisplayString,
|
|
juniSystemModuleCpuFiveSecUtilPct Integer32,
|
|
juniSystemModuleCpuOneMinAvgPct Integer32,
|
|
juniSystemModuleCpuFiveMinAvgPct Integer32 }
|
|
|
|
juniSystemModuleSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version identification of the currently executing operational software
|
|
on this module. If the module is in a state where the software version
|
|
is not known (e.g., module type mismatch), then the value of this object
|
|
will be a zero-length string."
|
|
::= { juniSystemModuleSoftwareEntry 2 }
|
|
|
|
juniSystemModuleCpuUtilPct OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Last available module CPU utilization percentage. A value of -1
|
|
indicates the utilization is unknown. This value is calculated over
|
|
a 5 second period."
|
|
::= { juniSystemModuleSoftwareEntry 3 }
|
|
|
|
juniSystemModuleMemUtilPct OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Percentage of module memory utilization. A value of -1 indicates the
|
|
utilization is unknown."
|
|
::= { juniSystemModuleSoftwareEntry 4 }
|
|
|
|
juniSystemModuleAdminStatus OBJECT-TYPE
|
|
SYNTAX JuniEnable
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides administrative control to enable/disable the module. This
|
|
object is read-only for certain types of modules."
|
|
::= { juniSystemModuleSoftwareEntry 5 }
|
|
|
|
juniSystemModuleControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation(0),
|
|
flush(1),
|
|
reset(2),
|
|
resetBackup(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrative control of this slot:
|
|
noOperation - Setting this value has no effect.
|
|
flush - Flushes the configuration associated with a module
|
|
type that previously occupied this slot. Used to
|
|
explicitly confirm that the slot is now empty, or
|
|
contains a different card type. The module must be
|
|
disabled when this value is asserted. See the
|
|
description for juniSystemModuleDisableReason.
|
|
reset - Resets the module.
|
|
resetBackup - Resets the module using the backup release file.
|
|
|
|
Get operations on this variable always return noOperation. Module types
|
|
that do not support these operations simply ignore them."
|
|
::= { juniSystemModuleSoftwareEntry 6 }
|
|
|
|
juniSystemModuleBootReleaseFile OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The boot release file name for this slot, with extension '.rel'. If a
|
|
file name is specified (not a zero-length string), then this release
|
|
file takes precedence over the subsystem boot release file
|
|
(juniSystemSubsystemBootReleaseFile) and the system-wide boot release
|
|
file (juniSystemBootReleaseFile) for just the module in this slot.
|
|
|
|
Some module types (e.g., ERX SRP modules) don't allow this object to be
|
|
set. On a set operation, if there is no file that matches the name
|
|
specified, then an inconsistentValue error will be returned. Setting
|
|
this object to a zero-length string deconfigures the slot-specific
|
|
primary release file."
|
|
DEFVAL { "" }
|
|
::= { juniSystemModuleSoftwareEntry 7 }
|
|
|
|
juniSystemModuleBootBackupReleaseFile OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The backup boot release file name for this slot, with extension '.rel'.
|
|
If a file name is specified (a non-zero-length string), then this
|
|
release file takes precedence over the subsystem boot backup release
|
|
file (juniSystemSubsystemBootBackupReleaseFile) and the system-wide boot
|
|
backup release file (juniSystemBootBackupReleaseFile) for just the
|
|
module in this slot.
|
|
|
|
This object cannot be set unless the system has a backup file, which
|
|
mean that juniSystemBootBackupReleaseFile must contain a file name (a
|
|
non-zero-length string). Some module types (e.g., ERX SRP modules)
|
|
don't allow this object to be set. On a set operation, if there is no
|
|
file that matches the name specified, then an inconsistentValue error
|
|
will be returned. Setting this object to a zero-length string
|
|
deconfigures the slot-specific backup release file."
|
|
DEFVAL { "" }
|
|
::= { juniSystemModuleSoftwareEntry 8 }
|
|
|
|
juniSystemModuleCpuFiveSecUtilPct OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Percentage of average CPU utilization for the last five sec for this
|
|
module. A value of -1 indicates the utilization is unknown."
|
|
::= { juniSystemModuleSoftwareEntry 9 }
|
|
|
|
juniSystemModuleCpuOneMinAvgPct OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Percentage of average CPU utilization for the last one minute for this
|
|
module. A value of -1 indicates the utilization is unknown."
|
|
::= { juniSystemModuleSoftwareEntry 10 }
|
|
|
|
juniSystemModuleCpuFiveMinAvgPct OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Percentage of average CPU utilization for the last five minutes for
|
|
this module. A value of -1 indicates the utilization is unknown."
|
|
::= { juniSystemModuleSoftwareEntry 11 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Module Redundancy objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemModuleRedundancyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemModuleRedundancyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of system module redundancy information. Note that modules
|
|
that do not support redundancy information will not appear in this
|
|
table."
|
|
::= { juniSystemModule 6 }
|
|
|
|
juniSystemModuleRedundancyEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemModuleRedundancyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry that provides information about a specific system module
|
|
in a particular slot location."
|
|
INDEX { juniSystemSlotNumber,
|
|
juniSystemSlotLevel }
|
|
::= { juniSystemModuleRedundancyTable 1 }
|
|
|
|
JuniSystemModuleRedundancyEntry ::= SEQUENCE {
|
|
juniSystemModuleRedundancyGroupId Unsigned32,
|
|
juniSystemModuleRedundancySpare TruthValue,
|
|
juniSystemModuleRedundancyAssociatedSlot Integer32,
|
|
juniSystemModuleRedundancyLockout JuniEnable,
|
|
juniSystemModuleRedundancyRevertControl INTEGER,
|
|
juniSystemModuleRedundancyRevertTime DateAndTime }
|
|
|
|
juniSystemModuleRedundancyGroupId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the redundancy group as derived from hardware settings."
|
|
::= { juniSystemModuleRedundancyEntry 1 }
|
|
|
|
juniSystemModuleRedundancySpare OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True only if this module is a spare redundant module."
|
|
::= { juniSystemModuleRedundancyEntry 2 }
|
|
|
|
juniSystemModuleRedundancyAssociatedSlot OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If this module is a primary redundant module, then the module at the
|
|
same slot level with the slot number identified by this variable is the
|
|
spare module that serves as this module's backup.
|
|
|
|
If this module is an active spare redundant module, then the module in
|
|
the slot identified by this variable is the primary module for which
|
|
this module is the spare.
|
|
|
|
If this module is an inactive spare redundant module, then the value of
|
|
this object is the slot number of the spare itself (the same value as
|
|
the first index)."
|
|
::= { juniSystemModuleRedundancyEntry 3 }
|
|
|
|
juniSystemModuleRedundancyLockout OBJECT-TYPE
|
|
SYNTAX JuniEnable
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides administrative control to enable/disable redundancy protection
|
|
for the module in this slot."
|
|
::= { juniSystemModuleRedundancyEntry 4 }
|
|
|
|
juniSystemModuleRedundancyRevertControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
immediate(1),
|
|
timeAndDate(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Per-module control for reverting a primary module back from its active
|
|
redundant spare module:
|
|
off - Disable reverting to the primary module.
|
|
immediate - Revert as soon as this primary module is ready to
|
|
enter the online state.
|
|
timeAndDate - Revert to this primary module at time specified by
|
|
juniSystemModuleRedundancyRevertTime, provided it is
|
|
in the inactive state.
|
|
|
|
This control only applies to primary modules; spare modules can only be
|
|
set to off(0)."
|
|
::= { juniSystemModuleRedundancyEntry 5 }
|
|
|
|
juniSystemModuleRedundancyRevertTime OBJECT-TYPE
|
|
SYNTAX DateAndTime (SIZE(8))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time associated with the timeAndDate (delayed) revert
|
|
operation. Only the local format for DateAndTime is supported. On a
|
|
set operation, if the time specified is prior to the current time, then
|
|
an inconsistent value error is returned.This object must be set concurrently
|
|
with juniSystemModuleRedundancyRevertControl { timeAndDate(2) }."
|
|
::= { juniSystemModuleRedundancyEntry 6 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- I/O Port objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of system physical I/O ports. The information in this table
|
|
reflects the ports for the expected module type in each slot; in event
|
|
of a module mismatch, this table permits navigation of the existing
|
|
configuration of the expected module type."
|
|
::= { juniSystemPort 1 }
|
|
|
|
juniSystemPortEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry describing a physical port of the system."
|
|
INDEX { juniSystemSlotNumber,
|
|
juniSystemSlotLevel,
|
|
juniSystemPortNumber }
|
|
::= { juniSystemPortTable 1 }
|
|
|
|
JuniSystemPortEntry ::= SEQUENCE {
|
|
juniSystemPortNumber Integer32,
|
|
juniSystemPortIfIndex InterfaceIndexOrZero,
|
|
juniSystemPortPhysicalIndex PhysicalIndex }
|
|
|
|
juniSystemPortNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port number of this physical port, relative to the slot in which it
|
|
resides. Each physical port is uniquely distinguished by its slot
|
|
number, slot level and port number. Port numbers are zero-based."
|
|
::= { juniSystemPortEntry 1 }
|
|
|
|
juniSystemPortIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the Interfaces MIB ifTable entry corresponding to this
|
|
physical port; if zero, the ifIndex is unknown or does not exist."
|
|
::= { juniSystemPortEntry 2 }
|
|
|
|
juniSystemPortPhysicalIndex OBJECT-TYPE
|
|
SYNTAX PhysicalIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entPhysicalIndex value assigned to this port. This index may be
|
|
use to retrieve other information about the port, such as description
|
|
and type, from the ENTITY-MIB.entPhysicalTable."
|
|
::= { juniSystemPortEntry 3 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Timing objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemAdminTimingSource OBJECT-TYPE
|
|
SYNTAX JuniSystemTimingSelector
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative timing source for the system. This variable is used
|
|
to select the desired timing source to be either primary, secondary or
|
|
tertiary. Setting this variable will cause the system to change to the
|
|
specified timing source, provided it is currently available. Setting
|
|
this value to error(4) is not allowed.
|
|
|
|
The system periodically monitors the status of the three timing sources.
|
|
If the systems current timing source fails, the system will
|
|
automatically downgrade to the next timing source. If the system is
|
|
configured to automatically upgrade (juniSystemTimingAutoUpgrade is set
|
|
to enable(1)) the system will switch back to the timing source indicated
|
|
by this variable when it becomes available.
|
|
|
|
A timing source failure can be detected by comparing the operational and
|
|
administrative timing sources. If they are not equal, the system has
|
|
swapped timing sources because the administratively set timing source is
|
|
in the error state."
|
|
::= { juniSystemTiming 1 }
|
|
|
|
juniSystemOperTimingSource OBJECT-TYPE
|
|
SYNTAX JuniSystemTimingSelector
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operational timing source for the system. The system periodically
|
|
monitors the status of three timing sources, primary, secondary and
|
|
tertiary. If the systems current timing source fails, the system will
|
|
automatically downgrade to the next timing source. If the system is
|
|
configured to automatically upgrade (juniSystemTimingAutoUpgrade is set
|
|
to enable(1)) the system will switch back to the higher timing source
|
|
when it becomes available."
|
|
::= { juniSystemTiming 2 }
|
|
|
|
juniSystemTimingAutoUpgrade OBJECT-TYPE
|
|
SYNTAX JuniEnable
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls the automatic timing selector upgrade. Setting
|
|
this object to disable(0) will prevent automatic upgrade to the next
|
|
highest timing selector. Setting this object to enable(1) will enable
|
|
the automatic upgrade of timing selectors."
|
|
DEFVAL { enable }
|
|
::= { juniSystemTiming 3 }
|
|
|
|
juniSystemTimingSelectorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemTimingSelectorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of system timing selectors. This table only contains entries for
|
|
the primary, secondary and tertiary selecors."
|
|
::= { juniSystemTiming 4 }
|
|
|
|
juniSystemTimingSelectorEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemTimingSelectorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry describing a system timing selector."
|
|
INDEX { juniSystemTimingSelectorIndex }
|
|
::= { juniSystemTimingSelectorTable 1 }
|
|
|
|
JuniSystemTimingSelectorEntry ::= SEQUENCE {
|
|
juniSystemTimingSelectorIndex JuniSystemTimingSelector,
|
|
juniSystemTimingSourceType INTEGER,
|
|
juniSystemTimingSourceIfIndex InterfaceIndexOrZero,
|
|
juniSystemTimingSourceLine INTEGER,
|
|
juniSystemTimingWorkingStatus INTEGER,
|
|
juniSystemTimingProtectedStatus INTEGER }
|
|
|
|
juniSystemTimingSelectorIndex OBJECT-TYPE
|
|
SYNTAX JuniSystemTimingSelector
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system timing selector index associated with this entry. There are
|
|
valid indexes for selector types primary(1), secondary(2), tertiary(3)."
|
|
::= { juniSystemTimingSelectorEntry 1 }
|
|
|
|
juniSystemTimingSourceType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
timingInterfaceIfIndex(1),
|
|
timingInternal(2),
|
|
timingLine(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system timing source type for this entry. This object must be set
|
|
to timingInterfaceIfIndex(1) when setting the
|
|
juniSystemTimingSourceIfIndex object or timingLine(3) when setting the
|
|
juniSystemTimingSourceLine object. Also, if the value of this object is
|
|
set to timingInternal(2), no other objects should be set, otherwise the
|
|
agent will return an error."
|
|
::= { juniSystemTimingSelectorEntry 2 }
|
|
|
|
juniSystemTimingSourceIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the interface selected as the system timing source. If
|
|
the juniSystemTimingSourceType object is not timingInterfaceIfIndex(1),
|
|
then reading this object will return a zero value. The agent will not
|
|
accept a set to this object unless the juniSystemTimingSourceType object
|
|
is set to timingInterfaceIfIndex(1)."
|
|
DEFVAL { 0 }
|
|
::= { juniSystemTimingSelectorEntry 3 }
|
|
|
|
juniSystemTimingSourceLine OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
timingSourceLineUndefined(0),
|
|
timingSourceLineE1PortA(1),
|
|
timingSourceLineE1PortB(2),
|
|
timingSourceLineT1PortA(3),
|
|
timingSourceLineT1PortB(4) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The line type timing source for this entry. If the
|
|
juniSystemTimingSourceType object is not timingLine(3), then reading
|
|
this object will return timingSourceLineUndefined(0). The agent will
|
|
not accept a set to this object unless the juniSystemTimingSourceType
|
|
object is set to timingLine(3). Attempting to set this object to
|
|
timingSourceLineUndefined(0) will always return an inconsistantValue
|
|
error. Attempting to set this object to a value that is not supported
|
|
on the type of system running the agent will result in an
|
|
inconsistantValue error."
|
|
DEFVAL { timingSourceLineUndefined }
|
|
::= { juniSystemTimingSelectorEntry 4 }
|
|
|
|
juniSystemTimingWorkingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
timingStatusOk(1),
|
|
timingStatusError(2),
|
|
timingStatusUnknown(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status associated with the working (normal) source of this system
|
|
timing working selector."
|
|
::= { juniSystemTimingSelectorEntry 5 }
|
|
|
|
juniSystemTimingProtectedStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
timingStatusOk(1),
|
|
timingStatusError(2),
|
|
timingStatusUnknown(3),
|
|
sourceNotProtected(4) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status associated with the protected (backup) source of this system
|
|
timing selector. If the system doesn't support protected timing
|
|
sources, then sourceNotProtected(4) will be returned."
|
|
::= { juniSystemTimingSelectorEntry 6 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Fabric objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemFabricSpeed OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "gigabits per second"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The speed of switching fabric, in gigabits per second."
|
|
::= { juniSystemFabric 1 }
|
|
|
|
juniSystemFabricRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fabric revision number. If unknown, a zero-length string is
|
|
reported."
|
|
::= { juniSystemFabric 2 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Non-Volatile Storage status objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemNvsCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of non-volatile storage (NVS) 'flash' cards in the system."
|
|
::= { juniSystemNvs 1 }
|
|
|
|
juniSystemNvsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemNvsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of NVS status information."
|
|
::= { juniSystemNvs 2 }
|
|
|
|
juniSystemNvsEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemNvsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry that provides the status information for a NVS flash
|
|
card."
|
|
INDEX { juniSystemNvsIndex }
|
|
::= { juniSystemNvsTable 1 }
|
|
|
|
JuniSystemNvsEntry ::= SEQUENCE {
|
|
juniSystemNvsIndex Integer32,
|
|
juniSystemNvsStatus INTEGER,
|
|
juniSystemNvsCapacity Unsigned32,
|
|
juniSystemNvsUtilPct Integer32,
|
|
juniSystemNvsPhysicalIndex PhysicalIndex }
|
|
|
|
juniSystemNvsIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index number of the NVS flash card. There is an entry in this
|
|
table for all values of this index in the range of 1 to the value of
|
|
juniSystemNvsCount."
|
|
::= { juniSystemNvsEntry 1 }
|
|
|
|
juniSystemNvsStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent(0),
|
|
writeProtected(1),
|
|
volumeError(2),
|
|
nearCapacity(3),
|
|
ok(4),
|
|
noConfigSpace(5) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of non-volatile storage (NVS):
|
|
notPresent - The SRP or the flash card is not accessible.
|
|
writeProtected - NVS is write-protected.
|
|
volumeError - Status poll of NVS failed.
|
|
nearCapacity - Utilization exceeds 85% of NVS capacity.
|
|
ok - NVS is fully operational with ample capacity.
|
|
noConfigSpace - Utilization exceeds the ability to save the
|
|
running configuration."
|
|
::= { juniSystemNvsEntry 2 }
|
|
|
|
juniSystemNvsCapacity OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "megabytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The capacity of NVS storage in megabytes."
|
|
::= { juniSystemNvsEntry 3 }
|
|
|
|
juniSystemNvsUtilPct OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of NVS storage used. A value of -1 indicates NVS
|
|
utilization is unknown."
|
|
::= { juniSystemNvsEntry 4 }
|
|
|
|
juniSystemNvsPhysicalIndex OBJECT-TYPE
|
|
SYNTAX PhysicalIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entPhysicalIndex value assigned to this NVS flash card. This index
|
|
may be use to retrieve other information about the NVS flash card, such
|
|
as description and type, from the ENTITY-MIB.entPhysicalTable."
|
|
::= { juniSystemNvsEntry 5 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Power element objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemPowerCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of power elements in the system."
|
|
::= { juniSystemPower 1 }
|
|
|
|
juniSystemPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of status variables for the system power elements."
|
|
::= { juniSystemPower 2 }
|
|
|
|
juniSystemPowerEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry describing status of a system power element."
|
|
INDEX { juniSystemPowerIndex }
|
|
::= { juniSystemPowerTable 1 }
|
|
|
|
JuniSystemPowerEntry ::= SEQUENCE {
|
|
juniSystemPowerIndex Integer32,
|
|
juniSystemPowerStatus INTEGER,
|
|
juniSystemPowerPhysicalIndex PhysicalIndex }
|
|
|
|
juniSystemPowerIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index number of the power element. There is an entry in this table
|
|
for all values of this index in the range of 1 to the value of
|
|
juniSystemPowerCount."
|
|
::= { juniSystemPowerEntry 1 }
|
|
|
|
juniSystemPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent(0),
|
|
inactive(1),
|
|
good(2),
|
|
failed(3),
|
|
sensorFailed(4),
|
|
unknown(5) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the power element:
|
|
notPresent - The power element is removed from the chassis.
|
|
inactive - No power is available from this element.
|
|
good - Power is available from this element.
|
|
failed - The power element is not working.
|
|
sensorFailed - The power element sensor has failed.
|
|
unknown - The status of the power element is not availiable."
|
|
::= { juniSystemPowerEntry 2 }
|
|
|
|
juniSystemPowerPhysicalIndex OBJECT-TYPE
|
|
SYNTAX PhysicalIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entPhysicalIndex value assigned to this power element. This index
|
|
may be use to retrieve other information about the power element, such
|
|
as description and type, from the ENTITY-MIB.entPhysicalTable."
|
|
::= { juniSystemPowerEntry 3 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Temperature control (fan subsystem) objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemFanCount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of fan subsystems that may be present in the system.
|
|
This is a fixed number for each product type."
|
|
::= { juniSystemTemperature 1 }
|
|
|
|
juniSystemFanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of status of the system's fan subsystems."
|
|
::= { juniSystemTemperature 2 }
|
|
|
|
juniSystemFanEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry describing status of a fan subsystem."
|
|
INDEX { juniSystemFanIndex }
|
|
::= { juniSystemFanTable 1 }
|
|
|
|
JuniSystemFanEntry ::= SEQUENCE {
|
|
juniSystemFanIndex Integer32,
|
|
juniSystemFanStatus INTEGER,
|
|
juniSystemFanPhysicalIndex PhysicalIndex }
|
|
|
|
juniSystemFanIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index number of the fan subsystem. This is a number in the range
|
|
of 1 to the value of juniSystemFanCount."
|
|
::= { juniSystemFanEntry 1 }
|
|
|
|
juniSystemFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
failed(0),
|
|
ok(1),
|
|
warning(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of fan subsystem.
|
|
failed - The fan subsystem has a critical failure, or has been
|
|
removed, and is now non-operational.
|
|
ok - All components are operational.
|
|
warning - The fan subsystem has a non-critical failure."
|
|
::= { juniSystemFanEntry 2 }
|
|
|
|
juniSystemFanPhysicalIndex OBJECT-TYPE
|
|
SYNTAX PhysicalIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entPhysicalIndex value assigned to this fan subsystem. This index
|
|
may be use to retrieve other information about the fan subsystem, such
|
|
as description and type, from the ENTITY-MIB.entPhysicalTable."
|
|
::= { juniSystemFanEntry 3 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Temperature sensor objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemTempCount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of possible temperature sensors in the system."
|
|
::= { juniSystemTemperature 3 }
|
|
|
|
juniSystemTempTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemTempEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of status of the system's temperature sensors."
|
|
::= { juniSystemTemperature 4 }
|
|
|
|
juniSystemTempEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemTempEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry describing status of a temperature sensor. Sensors are
|
|
located throughout the system. The ENTITY_MIB.entPhysicalTable provides
|
|
detailed information about the location of each sensor. The index for a
|
|
table entry is fixed based on a product-specific algorithm that uses the
|
|
maximum number of sensors that may be on any module type associated with
|
|
each of the available slots. This means that entries for sensors
|
|
associated with empty slots and the 'extra' sensors on modules that have
|
|
less than the maximum number of sensors for the slot type will have a
|
|
notPresent status."
|
|
INDEX { juniSystemTempIndex }
|
|
::= { juniSystemTempTable 1 }
|
|
|
|
JuniSystemTempEntry ::= SEQUENCE {
|
|
juniSystemTempIndex Integer32,
|
|
juniSystemTempStatus INTEGER,
|
|
juniSystemTempValue Integer32,
|
|
juniSystemTempPhysicalIndex Integer32 }
|
|
|
|
juniSystemTempIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An arbitrary number to uniquely identify the temperature sensor."
|
|
::= { juniSystemTempEntry 1 }
|
|
|
|
juniSystemTempStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
failed(1),
|
|
tooLow(2),
|
|
nominal(3),
|
|
tooHigh(4),
|
|
tooLowWarning(5),
|
|
tooHighWarning(6) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of a temperature sensor:
|
|
unknown - sensor is not present or is not accessible
|
|
failed - sensor is broken
|
|
tooLow - temperature is below nominal range
|
|
nominal - temperature is within nominal range
|
|
tooHigh - temperature is above nominal range
|
|
tooLowWarning - temperature is near the nominal lower limit
|
|
tooHighWarning - temperature is near the nominal upper limit "
|
|
::= { juniSystemTempEntry 2 }
|
|
|
|
juniSystemTempValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature measured by this sensor in degrees Celsius. This
|
|
measurement is valid only if the value of the corresponding
|
|
juniSystemTempStatus is tooLow, nominal or tooHigh."
|
|
::= { juniSystemTempEntry 3 }
|
|
|
|
juniSystemTempPhysicalIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entPhysicalIndex value assigned to this temperature sensor. If the
|
|
temperature sensor is not present this object will return a value of 0.
|
|
For non-zero values this index may be used to retrieve other information
|
|
about the temperature sensor from the ENTITY-MIB.entPhysicalTable, such
|
|
as description and location."
|
|
::= { juniSystemTempEntry 4 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Thermal protection objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemTempProtectionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
monitoring(1),
|
|
inHoldOff(2),
|
|
activatedHoldOffExpired(3),
|
|
activatedTempTooHigh(4) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Thermal Protection status:
|
|
off - No thermal protection.
|
|
monitoring - Monitoring.
|
|
inHoldOff - Hold off time has begun.
|
|
activatedHoldOffExpired - Hold off time has expired; the system
|
|
is in thermal protection mode.
|
|
activatedTempTooHigh - The temperature is too high, the system
|
|
is in thermal protection mode."
|
|
::= { juniSystemTemperature 5 }
|
|
|
|
juniSystemTempProtectionHoldOffTime OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1200)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time, in seconds, before the system enters Thermal Protection mode
|
|
after a critical thermal failure is detected."
|
|
DEFVAL { 150 }
|
|
::= { juniSystemTemperature 6 }
|
|
|
|
juniSystemTempProtectionHoldOffTimeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1200)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time remaining, in seconds, before the system enters Thermal
|
|
Protection mode while the ThermalProtectionStatus is set to inHoldOff.
|
|
The value decrements every second until it reaches zero, and the status
|
|
changes to activatedHoldOffExpired. When ThermalProtectionStatus is not
|
|
inHoldOff or activatedHoldOffExpired, the value is set to the hold off
|
|
time."
|
|
DEFVAL { 150 }
|
|
::= { juniSystemTemperature 7 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Resource utilization objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
--
|
|
-- Resource utilization status table
|
|
--
|
|
juniSystemUtilizationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemUtilizationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of status of the utilization of system resources. It is an
|
|
implementation option as to which resources (if any) are supported in
|
|
this table. It is also an implementation option as to whether the
|
|
threshold objects are supported for a particular instance."
|
|
::= { juniSystemUtilization 1 }
|
|
|
|
juniSystemUtilizationEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemUtilizationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry describing the status of the utilization of a system
|
|
resource."
|
|
INDEX { juniSystemUtilizationResourceType,
|
|
juniSystemUtilizationResourceSubType,
|
|
juniSystemUtilizationLocationType,
|
|
juniSystemUtilizationLocation }
|
|
::= { juniSystemUtilizationTable 1 }
|
|
|
|
JuniSystemUtilizationEntry ::= SEQUENCE {
|
|
juniSystemUtilizationResourceType INTEGER,
|
|
juniSystemUtilizationResourceSubType Integer32,
|
|
juniSystemUtilizationLocationType JuniSystemLocationType,
|
|
juniSystemUtilizationLocation JuniSystemLocation,
|
|
juniSystemUtilizationMaxCapacity Gauge32,
|
|
juniSystemUtilizationCurrentValue Gauge32,
|
|
juniSystemUtilizationThresholdRising Gauge32,
|
|
juniSystemUtilizationThresholdFalling Gauge32,
|
|
juniSystemUtilizationHoldDownTime Gauge32 }
|
|
|
|
juniSystemUtilizationResourceType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
interface(1),
|
|
memory(2) }
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This index identifies a type of enumerated value that is used for the
|
|
juniSystemUtilizationResourceSubType. See the DESCRIPTION for
|
|
juniSystemUtilizationResourceSubType for the mapping of Type to SubType
|
|
enumeration and the corresponding units of measure used for each type of
|
|
resource."
|
|
::= { juniSystemUtilizationEntry 1 }
|
|
|
|
juniSystemUtilizationResourceSubType OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This index uses an enumerated value that is different for each value of
|
|
juniSystemUtilizationResourceType. The following table shows the
|
|
mapping of Type to SubType enumeration and the corresponding units of
|
|
measure used for each type of resource.
|
|
|
|
Type SubType Units
|
|
-----------+-------------------------------+----------------------------
|
|
interface Juniper-UNI-IF-MIB.juniIfType number of interfaces
|
|
memory SNMPv2-TC.StorageType HOST-RESOURCES-MIB.KBytes "
|
|
::= { juniSystemUtilizationEntry 2 }
|
|
|
|
juniSystemUtilizationLocationType OBJECT-TYPE
|
|
SYNTAX JuniSystemLocationType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This index element identifies the format of the location information so
|
|
that the juniSystemUtilizationLocation index element can be properly
|
|
interpreted."
|
|
::= { juniSystemUtilizationEntry 3 }
|
|
|
|
juniSystemUtilizationLocation OBJECT-TYPE
|
|
SYNTAX JuniSystemLocation
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This index is used to specify the resource instance based on its
|
|
location. Its value is interpreted based on the location type
|
|
identified by the juniSystemUtilizationLocationType index element."
|
|
::= { juniSystemUtilizationEntry 4 }
|
|
|
|
juniSystemUtilizationMaxCapacity OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of units of the resource the system can support.
|
|
|
|
See the DESCRIPTION of juniSystemUtilizationResourceSubType for what
|
|
constitutes a unit of value for this object.
|
|
|
|
Note that for some resources this value may not always be achievable due
|
|
to other resource constraints."
|
|
::= { juniSystemUtilizationEntry 5 }
|
|
|
|
juniSystemUtilizationCurrentValue OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current number of units of the resource in the system.
|
|
|
|
See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
|
|
constitutes a unit of value for this object.
|
|
|
|
Note that some resource types may have instances that do not consume any
|
|
limited resources and therefore are not included in this count (e.g. IP
|
|
loopback interfaces do not consume routing resources and therefore don't
|
|
have a capacity limit, whereas 'external' IP interfaces do)."
|
|
::= { juniSystemUtilizationEntry 6 }
|
|
|
|
juniSystemUtilizationThresholdRising OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The threshold value (risingVal), which, in conjunction with
|
|
juniSystemUtilizationHoldDownTime (holdTime) and
|
|
juniSystemUtilizationThresholdFalling (fallingVal), is used to decide
|
|
when to trigger an event indicating that the resource utilization,
|
|
juniSystemUtilizationCurrentValue (currentVal), is approaching or has
|
|
reached its maximum capacity, juniSystemUtilizationMaxCapacity (maxVal).
|
|
|
|
See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
|
|
constitutes a unit of value for this object.
|
|
|
|
The value of fallingVal must be less than the value of this object.
|
|
|
|
This object provides one element in the formula used to determine when
|
|
to send a utilization notification. If the currentVal rises to equal
|
|
the risingVal and no other utilization event (either rising or falling)
|
|
has been triggered within the holdTime, or if the holdTime for a falling
|
|
threshold notification expires and the currentVal is at or above the
|
|
risingVal, then and only then is a rising threshold utilization
|
|
notification sent.
|
|
|
|
The following pseudo-code states the algorithm more precisely.
|
|
|
|
When the resource is created or initialized ( currentVal == 0 ):
|
|
lastTrapType = none;
|
|
lastTrapTime = 0;
|
|
|
|
When currentVal increments (increases):
|
|
if ( currentVal == risingVal &&
|
|
lastTrapTime + holdTime <= currentTime ) {
|
|
triggerUtilizationTrapRising();
|
|
lastTrapType = rising;
|
|
lastTrapTime = currentTime; }
|
|
|
|
When currentVal decrements (decreases):
|
|
if ( currentVal == fallingVal &&
|
|
lastTrapTime + holdTime <= currentTime ) {
|
|
triggerUtilizationTrapFalling();
|
|
lastTrapType = falling;
|
|
lastTrapTime = currentTime; }
|
|
|
|
When the rising threshold value is modified:
|
|
if ( currentVal < oldRisingVal &&
|
|
currentVal >= newRisingVal &&
|
|
lastTrapTime + holdTime <= currentTime )
|
|
triggerUtilizationTrapRising();
|
|
lastTrapType = rising;
|
|
lastTrapTime = currentTime; }
|
|
|
|
When the falling threshold value is modified:
|
|
if ( currentVal > oldFallingVal &&
|
|
currentVal <= newFallingVal &&
|
|
lastTrapTime + holdTime <= currentTime )
|
|
triggerUtilizationTrapFalling();
|
|
lastTrapType = falling;
|
|
lastTrapTime = currentTime; }
|
|
|
|
When a hold-down time expires (lastTrapTime + holdTime == currentTime):
|
|
switch ( lastTrapType ) {
|
|
case rising:
|
|
if ( currentVal <= fallingVal ) {
|
|
triggerUtilizationTrapFalling();
|
|
lastTrapType = falling;
|
|
lastTrapTime = currentTime; }
|
|
else {
|
|
lastTrapType = none; }
|
|
break;
|
|
case falling:
|
|
if ( currentVal >= risingVal ) {
|
|
triggerUtilizationTrapRising();
|
|
lastTrapType = rising;
|
|
lastTrapTime = currentTime; }
|
|
else {
|
|
lastTrapType = none; }
|
|
break; } "
|
|
::= { juniSystemUtilizationEntry 7 }
|
|
|
|
juniSystemUtilizationThresholdFalling OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The threshold value (fallingVal), which, in conjunction with
|
|
juniSystemUtilizationHoldDownTime (holdTime) and
|
|
juniSystemUtilizationThresholdRising (risingVal), is used to decide when
|
|
to trigger an event indicating that the resource utilization,
|
|
juniSystemUtilizationCurrentValue (currentVal), has fallen to or below
|
|
this level after having exceeded this value.
|
|
|
|
See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
|
|
constitutes a unit of value for this object.
|
|
|
|
The value of this object must be less than the value of risingVal.
|
|
|
|
This object provides one element in the formula used to determine when
|
|
to send a utilization notification. If the currentVal falls to equal
|
|
the fallingVal and no other utilization event (either rising or falling)
|
|
has been triggered within the holdTime, or if the holdTime for a rising
|
|
threshold notification expires and the currentVal is at or below the
|
|
fallingVal, then and only then is a falling threshold utilization
|
|
notification sent.
|
|
|
|
The pseudo-code in the juniSystemUtilizationThresholdRising DESCRIPTION
|
|
states the algorithm more precisely."
|
|
::= { juniSystemUtilizationEntry 8 }
|
|
|
|
juniSystemUtilizationHoldDownTime OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hold-down time (holdTime) used in conjunction with
|
|
juniSystemUtilizationThresholdRising (risingVal) and
|
|
juniSystemUtilizationThresholdFalling (fallingVal) to decide when to
|
|
trigger an event indicating that the resource utilization,
|
|
juniSystemUtilizationCurrentValue (currentVal), has reached or surpassed
|
|
one of the thresholds.
|
|
|
|
This object provides one element in the formula used to determine when
|
|
to send a utilization notification. If the resource utilization
|
|
increases to the rising threshold value but a prior rising or falling
|
|
utilization event has been triggered within this hold-down time then no
|
|
rising threshold utilization notification may be sent at that time. If
|
|
the resource utilization decreases to the falling threshold value but a
|
|
prior rising or falling utilization event has been triggered within this
|
|
hold-down time then no falling threshold utilization notification may be
|
|
sent at that time. However, if the end of a hold-down period for a
|
|
rising threshold utilization notification is reached and the current
|
|
value is at or below the falling threshold value, then a falling
|
|
threshold notification is sent and the hold-down timer is restarted.
|
|
Likewise, if the end of a hold-down period for a falling threshold
|
|
utilization notification is reached and the current value is at or above
|
|
the rising threshold value, then a rising threshold notification is sent
|
|
and the hold-down timer is restarted.
|
|
|
|
The pseudo-code in the juniSystemUtilizationThresholdRising DESCRIPTION
|
|
states the algorithm more precisely."
|
|
::= { juniSystemUtilizationEntry 9 }
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Task profiling (process cpu utilization) objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemCpuUtilizationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemCpuUtilizationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of status of the cpu utilization by various tasks."
|
|
::= { juniSystemUtilization 2 }
|
|
|
|
juniSystemCpuUtilizationEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemCpuUtilizationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry describing cpu utilization of a particular task."
|
|
INDEX { juniSystemCpuUtilizationTimeMark,
|
|
juniSystemCpuUtilizationTaskName }
|
|
::= { juniSystemCpuUtilizationTable 1 }
|
|
|
|
JuniSystemCpuUtilizationEntry ::= SEQUENCE {
|
|
juniSystemCpuUtilizationTimeMark JuniTimeFilter,
|
|
juniSystemCpuUtilizationTaskName JuniSystemTaskName,
|
|
juniSystemCpuUtilizationInvoked Integer32,
|
|
juniSystemCpuUtilizationInvokationPerSec Integer32,
|
|
juniSystemCpuUtilizationTotalRunningTime Integer32,
|
|
juniSystemCpuUtilizationPercentageRunningTime Integer32,
|
|
juniSystemCpuUtilizationAverageTimePerInvokation Integer32,
|
|
juniSystemCpuUtilizationFiveSecondUtilization Integer32,
|
|
juniSystemCpuUtilizationOneMinuteUtilization Integer32,
|
|
juniSystemCpuUtilizationFiveMinuteUtilization Integer32,
|
|
juniSystemCpuUtilizationNumberOfInstances Integer32 }
|
|
|
|
juniSystemCpuUtilizationTimeMark OBJECT-TYPE
|
|
SYNTAX JuniTimeFilter
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A TimeFilter for this task profile entry. Allows GetNext and GetBulk
|
|
to find task profile rows which have changed since a specified
|
|
value of sysUptime."
|
|
REFERENCE
|
|
"Refer to RFC 2021 for the definition of the TimeFilter, its usage and
|
|
implementation notes."
|
|
::= { juniSystemCpuUtilizationEntry 1 }
|
|
|
|
juniSystemCpuUtilizationTaskName OBJECT-TYPE
|
|
SYNTAX JuniSystemTaskName
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Task name associated with this task profile entry."
|
|
::= { juniSystemCpuUtilizationEntry 2 }
|
|
|
|
juniSystemCpuUtilizationInvoked OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times task associated with this task profile
|
|
entry being invoked."
|
|
::= { juniSystemCpuUtilizationEntry 3 }
|
|
|
|
juniSystemCpuUtilizationInvokationPerSec OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Rate of invokation for the task associated with this task
|
|
profile entry."
|
|
::= { juniSystemCpuUtilizationEntry 4 }
|
|
|
|
juniSystemCpuUtilizationTotalRunningTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milli Seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total running time for the task associated with this task
|
|
profile entry."
|
|
::= { juniSystemCpuUtilizationEntry 5 }
|
|
|
|
juniSystemCpuUtilizationPercentageRunningTime OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Percentage running time for the task associated with this task
|
|
profile entry."
|
|
::= { juniSystemCpuUtilizationEntry 6 }
|
|
|
|
juniSystemCpuUtilizationAverageTimePerInvokation OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "micro Seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average running time per invokation for the task associated
|
|
with this task profile entry."
|
|
::= { juniSystemCpuUtilizationEntry 7 }
|
|
|
|
juniSystemCpuUtilizationFiveSecondUtilization OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Utilization in terms of percentage during the five seconds measurement
|
|
interval for the task associated with this task profile entry."
|
|
::= { juniSystemCpuUtilizationEntry 8 }
|
|
|
|
juniSystemCpuUtilizationOneMinuteUtilization OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Utilization in terms of percentage during the one minute measurement
|
|
interval for the task associated with this task profile entry."
|
|
::= { juniSystemCpuUtilizationEntry 9 }
|
|
|
|
juniSystemCpuUtilizationFiveMinuteUtilization OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Utilization in terms of percentage during the five minutes measurement
|
|
interval for the task associated with this task profile entry."
|
|
::= { juniSystemCpuUtilizationEntry 10 }
|
|
|
|
juniSystemCpuUtilizationNumberOfInstances OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of instances consolidated for CPU utilization calculation in this
|
|
task profile entry."
|
|
::= { juniSystemCpuUtilizationEntry 11 }
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- ISSU objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemIssuState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
idle(1),
|
|
initializing(2),
|
|
initialized(3),
|
|
upgrading(4),
|
|
stopping(5) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of the system with respect to ISSU upgrade:
|
|
idle - ISSU is currently idle
|
|
initializing - ISSU initialization is in-progress
|
|
initialized - ISSU has successfully initialized
|
|
upgrading - ISSU is currently upgrading to the new armed release
|
|
stopping - ISSU is currently in the process of stopping
|
|
|
|
This object is supported on the second generation E-series
|
|
platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
|
|
releases. This object is also supported on ERX-1440 in JUNOSe 9.2
|
|
and subsequent system releases."
|
|
::= { juniSystemIssu 1 }
|
|
|
|
juniSystemIssuRunningReleaseFile OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The currently running release file name, with extension '.rel'.
|
|
The system was booted last time with this release file.
|
|
|
|
This object is supported on the second generation E-series
|
|
platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
|
|
releases. This object is also supported on ERX-1440 in JUNOSe 9.2
|
|
and subsequent system releases."
|
|
::= { juniSystemIssu 2 }
|
|
|
|
juniSystemIssuArmedReleaseFile OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The currently armed release file name, with extension '.rel'.
|
|
The system will be booted with this release file, after ISSU (if
|
|
it is not aborted).
|
|
|
|
This object is supported on the second generation E-series
|
|
platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
|
|
releases. This object is also supported on ERX-1440 in JUNOSe 9.2
|
|
and subsequent system releases."
|
|
::= { juniSystemIssu 3 }
|
|
|
|
juniSystemIssuStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
warning(2),
|
|
error(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the system with respect to ISSU upgrade.
|
|
ok - no error or warning found
|
|
warning - at least one upgrade warning found, upgrade is possible
|
|
error - at least one upgrade error found, upgrade is not possible
|
|
|
|
This object is supported on the second generation E-series
|
|
platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
|
|
releases. This object is also supported on ERX-1440 in JUNOSe 9.2
|
|
and subsequent system releases."
|
|
::= { juniSystemIssu 4 }
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- ISSU upgrade Criteria
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemIssuCriteriaTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniSystemIssuCriteriaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Table of criteria for an ISSU initialization.
|
|
|
|
This table will be empty for unsupported platforms. These objects
|
|
are supported on the second generation E-series platform
|
|
family (E320 & E120) in JUNOSe 9.0 and subsequent system releases.
|
|
This object is also supported on ERX-1440 in JUNOSe 9.2 and
|
|
subsequent system releases."
|
|
::= { juniSystemIssu 5 }
|
|
|
|
juniSystemIssuCriteriaEntry OBJECT-TYPE
|
|
SYNTAX JuniSystemIssuCriteriaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table entry describing the criteria for an ISSU initialization."
|
|
INDEX { juniSystemIssuCriteriaIndex }
|
|
::= { juniSystemIssuCriteriaTable 1 }
|
|
|
|
JuniSystemIssuCriteriaEntry ::= SEQUENCE {
|
|
juniSystemIssuCriteriaIndex Integer32,
|
|
juniSystemIssuCriteriaDescription DisplayString,
|
|
juniSystemIssuCriteriaStatus INTEGER }
|
|
|
|
juniSystemIssuCriteriaIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index associated with an entry of the system ISSU Criteria Table."
|
|
::= { juniSystemIssuCriteriaEntry 1 }
|
|
|
|
juniSystemIssuCriteriaDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"To initialize ISSU, few criteria need to be met. If these criteria
|
|
were not met, ISSU cannot be initialized. This object provides the
|
|
criteria details."
|
|
::= { juniSystemIssuCriteriaEntry 2 }
|
|
|
|
juniSystemIssuCriteriaStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes(1),
|
|
no(2),
|
|
conditional(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"To initialize ISSU, few criteria need to be met. If these criteria
|
|
were not met, ISSU cannot be initialized. This object indicates
|
|
whether a criteria has met. It will be conditional when that the
|
|
user can choose to accept the consequences of proceeding with ISSU
|
|
with non-ideal operating conditions."
|
|
::= { juniSystemIssuCriteriaEntry 3 }
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Notification control objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemMemUtilTrapEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the sending of primary system processor memory utilization
|
|
events. Setting the value of this object to true(1) will cause system
|
|
memory utilization event notifications, if they occur, to be sent to the
|
|
management entity on this system. Setting the value of this object to
|
|
false(2) will disable memory utilization event notifications."
|
|
DEFVAL { false }
|
|
::= { juniSystemGeneral 19 }
|
|
|
|
juniSystemReloadSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In a juniSystemReloadCommand notification, this object indicates the
|
|
number of the slot that is being reloaded. Note that slot numbers are
|
|
zero-based."
|
|
::= { juniSystemGeneral 20 }
|
|
|
|
juniSystemUtilizationThresholdDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rising(1),
|
|
falling(2) }
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of resource utilization notification being sent. See the
|
|
DESCRIPTIONs for the juniSystemUtilizationTable elements for details on
|
|
what conditions trigger a resource utilization notification."
|
|
::= { juniSystemGeneral 21 }
|
|
|
|
juniSystemUtilizationTrapEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the sending of system resource utilization threshold
|
|
notifications. Setting the value of this object to true(1) will allow
|
|
resource utilization threshold event notifications, if they occur, to be
|
|
sent to the management entity on this system. Setting the value of this
|
|
object to false(2) will disable resource utilization threshold
|
|
utilization event notifications."
|
|
DEFVAL { true }
|
|
::= { juniSystemGeneral 22 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Notifications
|
|
--
|
|
-- The juniSystemTrap OBJECT IDENTIFIER is used to define SNMPv2 notifications
|
|
-- that may be translated into SNMPv1 traps.
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemHighMemUtil NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
juniSystemMemCapacity,
|
|
juniSystemMemUtilPct,
|
|
juniSystemAbatedMemUtilThreshold,
|
|
juniSystemHighMemUtilThreshold,
|
|
juniSystemMemKBytesCapacity }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Report system memory utilization has met the conditions of
|
|
juniSystemHighMemUtilThreshold. If the memory capacity is greater than
|
|
2147483647, a -1 value is returned in juniSystemMemCapacity, and the
|
|
actual memory capacity in units of 1024 bytes is returned in
|
|
juniSystemMemKBytesCapacity."
|
|
::= { juniSystemTrap 1 }
|
|
|
|
juniSystemAbatedMemUtil NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
juniSystemMemCapacity,
|
|
juniSystemMemUtilPct,
|
|
juniSystemAbatedMemUtilThreshold,
|
|
juniSystemHighMemUtilThreshold,
|
|
juniSystemMemKBytesCapacity }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports system memory utilization has met the conditions of
|
|
juniSystemAbatedMemUtilThreshold. If the memory capacity is greater
|
|
than 2147483647, a -1 value is returned in juniSystemMemCapacity, and
|
|
the actual memory capacity in units of 1024 bytes is returned in
|
|
juniSystemMemKBytesCapacity."
|
|
::= { juniSystemTrap 2 }
|
|
|
|
juniSystemModuleOperStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
juniSystemModuleCurrentType,
|
|
juniSystemModuleAdminStatus,
|
|
juniSystemModuleOperStatus,
|
|
juniSystemModuleDisableReason,
|
|
juniSystemModuleDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports a status change for a module. This trap is generated on a
|
|
transition into a stable state (online or disabled) or on a transition
|
|
out of online. If redundancy is supported for the module
|
|
(juniSystemModuleRedundancySupported is true(1)), then the
|
|
juniSystemModuleSpareServer and juniSystemModuleAssociatedSlot objects
|
|
are also included in the notification."
|
|
::= { juniSystemTrap 3 }
|
|
|
|
juniSystemPowerStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
entPhysicalDescr,
|
|
juniSystemPowerStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports a change in the status of a power element."
|
|
::= { juniSystemTrap 4 }
|
|
|
|
juniSystemFanStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
entPhysicalDescr,
|
|
juniSystemFanStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports a transition between the three states of the fan subsystem.
|
|
When the fan subsystem transitions to the failed state the Thermal
|
|
Protection hold off time begins."
|
|
::= { juniSystemTrap 5 }
|
|
|
|
juniSystemTempStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
juniSystemTempStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports a change in the temperature status. When the status
|
|
transitions to the tooHigh state the system enters Thermal Protection
|
|
mode."
|
|
::= { juniSystemTrap 6 }
|
|
|
|
juniSystemTempProtectionStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
juniSystemTempProtectionStatus,
|
|
juniSystemTempProtectionHoldOffTimeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification about changes in the state of Thermal Protection. This
|
|
notification is sent when the tempProtectionStatus changes. It is also
|
|
sent when the holdOffTimeRemaining is 50% of the holdOffTime."
|
|
::= { juniSystemTrap 7 }
|
|
|
|
juniSystemReloadCommand NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification indicating that a slot or the entire system is about to
|
|
restart due to a system console reload command. If the reload is only
|
|
on an individual slot then the following object is included in the
|
|
notification:
|
|
juniSystemReloadSlotNumber "
|
|
::= { juniSystemTrap 8 }
|
|
|
|
juniSystemUtilizationThreshold NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
juniSystemUtilizationThresholdDirection,
|
|
juniSystemUtilizationMaxCapacity,
|
|
juniSystemUtilizationCurrentValue,
|
|
juniSystemUtilizationThresholdRising,
|
|
juniSystemUtilizationThresholdFalling,
|
|
juniSystemUtilizationHoldDownTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification indicating that a system resource's utilization has met
|
|
the conditions of juniSystemUtilizationThresholdDirection. See the
|
|
DESCRIPTIONs for the juniSystemUtilizationTable elements for details on
|
|
what conditions trigger a resource utilization notification."
|
|
::= { juniSystemTrap 9 }
|
|
|
|
juniSystemIssuStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
juniSystemIssuState }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification about changes in the status, in case of ISSU upgrade.
|
|
This notification is sent when the juniSystemIssuState changes. The
|
|
trap parameter will indicate the current value of the
|
|
juniSystemIssuState.
|
|
|
|
This notification is supported on the second generation E-series
|
|
platform family (E320 & E120) from 9.0 release onwards. This
|
|
object is also supported on ERX-1440 in JUNOSe 9.2 and
|
|
subsequent system releases."
|
|
::= { juniSystemTrap 10 }
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Conformance information
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniSystemCompliances OBJECT IDENTIFIER ::= { juniSystemConformance 1 }
|
|
juniSystemGroups OBJECT IDENTIFIER ::= { juniSystemConformance 2 }
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
juniSystemCompliance MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities that implement the Juniper
|
|
E-series System MIB. This statement became obsolete when system
|
|
resource utilization support was added."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniSystemGeneralGroup,
|
|
juniSystemSubsystemGroup,
|
|
juniSystemModuleGroup,
|
|
juniSystemPortGroup,
|
|
juniSystemTimingGroup,
|
|
juniSystemFabricGroup,
|
|
juniSystemNvsGroup,
|
|
juniSystemPowerGroup,
|
|
juniSystemTemperatureGroup,
|
|
juniSystemNotificationObjectsGroup,
|
|
juniSystemNotificationGroup }
|
|
::= { juniSystemCompliances 1 } -- JUNOSe 4.1
|
|
|
|
juniSystemCompliance2 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities that implement the Juniper
|
|
E-series System MIB. This statement became obsolete when the system
|
|
resource utilization trap enabled and the KByte memory capacilty objects
|
|
were added."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniSystemGeneralGroup,
|
|
juniSystemSubsystemGroup,
|
|
juniSystemModuleGroup,
|
|
juniSystemPortGroup,
|
|
juniSystemTimingGroup,
|
|
juniSystemFabricGroup,
|
|
juniSystemNvsGroup,
|
|
juniSystemPowerGroup,
|
|
juniSystemTemperatureGroup,
|
|
juniSystemUtilizationGroup,
|
|
juniSystemNotificationObjectsGroup,
|
|
juniSystemNotificationGroup2 }
|
|
OBJECT juniSystemUtilizationMaxCapacity
|
|
MIN-ACCESS accessible-for-notify
|
|
DESCRIPTION
|
|
"This object is only required to be included in the
|
|
juniSystemUtilizationThreshold notifications."
|
|
OBJECT juniSystemUtilizationCurrentValue
|
|
MIN-ACCESS accessible-for-notify
|
|
DESCRIPTION
|
|
"This object is only required to be included in the
|
|
juniSystemUtilizationThreshold notifications."
|
|
OBJECT juniSystemUtilizationThresholdRising
|
|
MIN-ACCESS accessible-for-notify
|
|
DESCRIPTION
|
|
"This object may have a fixed value in a particular
|
|
implementation and is therefore only required to be included
|
|
in the juniSystemUtilizationThreshold notifications."
|
|
OBJECT juniSystemUtilizationThresholdFalling
|
|
MIN-ACCESS accessible-for-notify
|
|
DESCRIPTION
|
|
"This object may have a fixed value in a particular
|
|
implementation and is therefore only required to be included
|
|
in the juniSystemUtilizationThreshold notifications."
|
|
OBJECT juniSystemUtilizationHoldDownTime
|
|
MIN-ACCESS accessible-for-notify
|
|
DESCRIPTION
|
|
"This object may have a fixed value in a particular
|
|
implementation and is therefore only required to be included
|
|
in the juniSystemUtilizationThreshold notifications."
|
|
::= { juniSystemCompliances 2 } -- JUNOSe 5.0
|
|
|
|
juniSystemCompliance3 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities that implement the Juniper
|
|
E-series System MIB. This statement became obsolete when the module
|
|
level span object was added."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniSystemGeneralGroup2,
|
|
juniSystemSubsystemGroup,
|
|
juniSystemModuleGroup,
|
|
juniSystemPortGroup,
|
|
juniSystemTimingGroup,
|
|
juniSystemFabricGroup,
|
|
juniSystemNvsGroup,
|
|
juniSystemPowerGroup,
|
|
juniSystemTemperatureGroup,
|
|
juniSystemUtilizationGroup,
|
|
juniSystemNotificationObjectsGroup,
|
|
juniSystemNotificationGroup2 }
|
|
::= { juniSystemCompliances 3 } -- JUNOSe 5.2
|
|
|
|
juniSystemCompliance4 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities that implement the Juniper
|
|
E-series System MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniSystemGeneralGroup2,
|
|
juniSystemSubsystemGroup,
|
|
juniSystemModuleGroup2,
|
|
juniSystemPortGroup,
|
|
juniSystemTimingGroup,
|
|
juniSystemFabricGroup,
|
|
juniSystemNvsGroup,
|
|
juniSystemPowerGroup,
|
|
juniSystemTemperatureGroup,
|
|
juniSystemUtilizationGroup,
|
|
juniSystemNotificationObjectsGroup,
|
|
juniSystemNotificationGroup2 }
|
|
::= { juniSystemCompliances 4 } -- JUNOSe 6.0
|
|
|
|
juniSystemCompliance5 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities that implement the Juniper
|
|
E-series System MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniSystemGeneralGroup2,
|
|
juniSystemSubsystemGroup,
|
|
juniSystemModuleGroup2,
|
|
juniSystemPortGroup,
|
|
juniSystemTimingGroup,
|
|
juniSystemFabricGroup,
|
|
juniSystemNvsGroup,
|
|
juniSystemPowerGroup,
|
|
juniSystemTemperatureGroup,
|
|
juniSystemUtilizationGroup2,
|
|
juniSystemNotificationObjectsGroup,
|
|
juniSystemNotificationGroup2 }
|
|
::= { juniSystemCompliances 5 } -- JUNOSe 7.3
|
|
|
|
juniSystemCompliance6 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for entities that implement the Juniper
|
|
E-series System MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniSystemGeneralGroup2,
|
|
juniSystemSubsystemGroup,
|
|
juniSystemModuleGroup3,
|
|
juniSystemPortGroup,
|
|
juniSystemTimingGroup,
|
|
juniSystemFabricGroup,
|
|
juniSystemNvsGroup,
|
|
juniSystemPowerGroup,
|
|
juniSystemTemperatureGroup,
|
|
juniSystemUtilizationGroup2,
|
|
juniSystemNotificationObjectsGroup,
|
|
juniSystemNotificationGroup2 }
|
|
::= { juniSystemCompliances 6 } -- JUNOSe 8.0
|
|
|
|
juniSystemCompliance7 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities that implement the Juniper
|
|
E-series System MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniSystemGeneralGroup2,
|
|
juniSystemSubsystemGroup,
|
|
juniSystemModuleGroup3,
|
|
juniSystemPortGroup,
|
|
juniSystemTimingGroup,
|
|
juniSystemFabricGroup,
|
|
juniSystemNvsGroup,
|
|
juniSystemPowerGroup,
|
|
juniSystemTemperatureGroup,
|
|
juniSystemUtilizationGroup2,
|
|
juniSystemNotificationObjectsGroup,
|
|
juniSystemIssuGroup,
|
|
juniSystemNotificationGroup3 }
|
|
::= { juniSystemCompliances 7 } -- JUNOSe 9.0
|
|
--
|
|
-- units of conformance
|
|
--
|
|
juniSystemGeneralGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemSwVersion,
|
|
juniSystemSwBuildDate,
|
|
juniSystemMemUtilPct,
|
|
juniSystemMemCapacity,
|
|
juniSystemHighMemUtilThreshold,
|
|
juniSystemAbatedMemUtilThreshold,
|
|
juniSystemMemUtilTrapEnable,
|
|
|
|
juniSystemBootConfigControl,
|
|
juniSystemBootBackupConfigControl,
|
|
juniSystemBootForceBackupControl,
|
|
juniSystemBootAutoRevertControl,
|
|
juniSystemBootAutoRevertCountTolerance,
|
|
juniSystemBootAutoRevertTimeTolerance,
|
|
juniSystemBootReleaseFile,
|
|
juniSystemBootConfigFile,
|
|
juniSystemBootBackupReleaseFile,
|
|
juniSystemBootBackupConfigFile,
|
|
|
|
juniSystemRedundancyRevertControl,
|
|
juniSystemRedundancyRevertTimeOfDay }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of management objects providing system-wide
|
|
software status and control information in a Juniper E-series product.
|
|
This group became obsolete when the system resource utilization
|
|
threshold trap enable/disable and the KByte memory capacilty objects
|
|
were added."
|
|
::= { juniSystemGroups 1 } -- JUNOSe 4.1
|
|
|
|
juniSystemSubsystemGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemSubsystemName,
|
|
juniSystemSubsystemBootReleaseFile,
|
|
juniSystemSubsystemBootBackupReleaseFile }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects providing subsystem software control
|
|
information in a Juniper E-series product."
|
|
::= { juniSystemGroups 2 } -- JUNOSe 4.1
|
|
|
|
juniSystemModuleGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemMaxSlotNumber,
|
|
juniSystemMaxModulesPerSlot,
|
|
|
|
juniSystemSlotStatus,
|
|
juniSystemSlotType,
|
|
|
|
juniSystemModuleOperStatus,
|
|
juniSystemModuleDisableReason,
|
|
juniSystemModuleLastChange,
|
|
juniSystemModuleCurrentType,
|
|
juniSystemModuleExpectedType,
|
|
juniSystemModuleDescr,
|
|
juniSystemModuleSlotSpan,
|
|
juniSystemModulePortCount,
|
|
juniSystemModuleSerialNumber,
|
|
juniSystemModuleAssemblyPartNumber,
|
|
juniSystemModuleAssemblyRev,
|
|
juniSystemModulePhysicalIndex,
|
|
juniSystemModuleSoftwareSupport,
|
|
juniSystemModuleRedundancySupport,
|
|
|
|
juniSystemModuleSoftwareVersion,
|
|
juniSystemModuleCpuUtilPct,
|
|
juniSystemModuleMemUtilPct,
|
|
juniSystemModuleAdminStatus,
|
|
juniSystemModuleControl,
|
|
juniSystemModuleBootReleaseFile,
|
|
juniSystemModuleBootBackupReleaseFile,
|
|
|
|
juniSystemModuleRedundancyGroupId,
|
|
juniSystemModuleRedundancySpare,
|
|
juniSystemModuleRedundancyAssociatedSlot,
|
|
juniSystemModuleRedundancyLockout,
|
|
juniSystemModuleRedundancyRevertControl,
|
|
juniSystemModuleRedundancyRevertTime }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of management objects that provide system module
|
|
information in a Juniper E-series product. This group became obsolete
|
|
when the module level span object was added."
|
|
::= { juniSystemGroups 3 } -- JUNOSe 4.1
|
|
|
|
juniSystemPortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemPortPhysicalIndex,
|
|
juniSystemPortIfIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects providing physical I/O port
|
|
information in a Juniper E-series product."
|
|
::= { juniSystemGroups 4 } -- JUNOSe 4.1
|
|
|
|
juniSystemTimingGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemAdminTimingSource,
|
|
juniSystemOperTimingSource,
|
|
juniSystemTimingAutoUpgrade,
|
|
|
|
juniSystemTimingSourceType,
|
|
juniSystemTimingSourceIfIndex,
|
|
juniSystemTimingSourceLine,
|
|
juniSystemTimingWorkingStatus,
|
|
juniSystemTimingProtectedStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects providing system timing source
|
|
information in a Juniper E-series product."
|
|
::= { juniSystemGroups 5 } -- JUNOSe 4.1
|
|
|
|
juniSystemFabricGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemFabricSpeed,
|
|
juniSystemFabricRev }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects providing system fabric information
|
|
in a Juniper E-series product."
|
|
::= { juniSystemGroups 6 } -- JUNOSe 4.1
|
|
|
|
juniSystemNvsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemNvsCount,
|
|
|
|
juniSystemNvsPhysicalIndex,
|
|
juniSystemNvsStatus,
|
|
juniSystemNvsCapacity,
|
|
juniSystemNvsUtilPct }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects providing system non-volatile
|
|
storage (NVS) information in a Juniper E-series product."
|
|
::= { juniSystemGroups 7 } -- JUNOSe 4.1
|
|
|
|
juniSystemPowerGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemPowerCount,
|
|
|
|
juniSystemPowerPhysicalIndex,
|
|
juniSystemPowerStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects providing system power element
|
|
information in a Juniper E-series product."
|
|
::= { juniSystemGroups 8 } -- JUNOSe 4.1
|
|
|
|
juniSystemTemperatureGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemFanCount,
|
|
|
|
juniSystemFanPhysicalIndex,
|
|
juniSystemFanStatus,
|
|
|
|
juniSystemTempCount,
|
|
|
|
juniSystemTempStatus,
|
|
juniSystemTempValue,
|
|
juniSystemTempPhysicalIndex,
|
|
|
|
juniSystemTempProtectionStatus,
|
|
juniSystemTempProtectionHoldOffTime,
|
|
juniSystemTempProtectionHoldOffTimeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects providing system temperature control
|
|
information in a Juniper E-series product."
|
|
::= { juniSystemGroups 9 } -- JUNOSe 4.1
|
|
|
|
juniSystemNotificationObjectsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemReloadSlotNumber }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects providing system information for
|
|
notification in a Juniper E-series product."
|
|
::= { juniSystemGroups 10 } -- JUNOSe 4.1
|
|
|
|
juniSystemNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
juniSystemHighMemUtil,
|
|
juniSystemAbatedMemUtil,
|
|
juniSystemModuleOperStatusChange,
|
|
juniSystemPowerStatusChange,
|
|
juniSystemFanStatusChange,
|
|
juniSystemTempStatusChange,
|
|
juniSystemTempProtectionStatusChange,
|
|
juniSystemReloadCommand }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of notifications for system events in a Juniper
|
|
E-series product. This group became obsolete when the system resource
|
|
utilization notification was added."
|
|
::= { juniSystemGroups 11 } -- JUNOSe 4.1
|
|
|
|
juniSystemUtilizationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemUtilizationMaxCapacity,
|
|
juniSystemUtilizationCurrentValue,
|
|
juniSystemUtilizationThresholdRising,
|
|
juniSystemUtilizationThresholdFalling,
|
|
juniSystemUtilizationHoldDownTime,
|
|
juniSystemUtilizationThresholdDirection }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of management objects providing system resource
|
|
utilization information and notification control for a Juniper E-series
|
|
product."
|
|
::= { juniSystemGroups 12 } -- JUNOSe 5.0
|
|
|
|
juniSystemNotificationGroup2 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
juniSystemHighMemUtil,
|
|
juniSystemAbatedMemUtil,
|
|
juniSystemModuleOperStatusChange,
|
|
juniSystemPowerStatusChange,
|
|
juniSystemFanStatusChange,
|
|
juniSystemTempStatusChange,
|
|
juniSystemTempProtectionStatusChange,
|
|
juniSystemReloadCommand,
|
|
juniSystemUtilizationThreshold }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"A collection of notifications for system events in a Juniper E-series
|
|
product."
|
|
::= { juniSystemGroups 13 } -- JUNOSe 5.0
|
|
|
|
juniSystemGeneralGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemSwVersion,
|
|
juniSystemSwBuildDate,
|
|
juniSystemMemUtilPct,
|
|
juniSystemMemCapacity,
|
|
juniSystemMemKBytesCapacity,
|
|
juniSystemHighMemUtilThreshold,
|
|
juniSystemAbatedMemUtilThreshold,
|
|
juniSystemMemUtilTrapEnable,
|
|
juniSystemUtilizationTrapEnable,
|
|
|
|
juniSystemBootConfigControl,
|
|
juniSystemBootBackupConfigControl,
|
|
juniSystemBootForceBackupControl,
|
|
juniSystemBootAutoRevertControl,
|
|
juniSystemBootAutoRevertCountTolerance,
|
|
juniSystemBootAutoRevertTimeTolerance,
|
|
juniSystemBootReleaseFile,
|
|
juniSystemBootConfigFile,
|
|
juniSystemBootBackupReleaseFile,
|
|
juniSystemBootBackupConfigFile,
|
|
|
|
juniSystemRedundancyRevertControl,
|
|
juniSystemRedundancyRevertTimeOfDay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects providing system-wide software
|
|
status and control information in a Juniper E-series product."
|
|
::= { juniSystemGroups 14 } -- JUNOSe 5.2
|
|
|
|
juniSystemModuleGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemMaxSlotNumber,
|
|
juniSystemMaxModulesPerSlot,
|
|
|
|
juniSystemSlotStatus,
|
|
juniSystemSlotType,
|
|
|
|
juniSystemModuleOperStatus,
|
|
juniSystemModuleDisableReason,
|
|
juniSystemModuleLastChange,
|
|
juniSystemModuleCurrentType,
|
|
juniSystemModuleExpectedType,
|
|
juniSystemModuleDescr,
|
|
juniSystemModuleSlotSpan,
|
|
juniSystemModulePortCount,
|
|
juniSystemModuleSerialNumber,
|
|
juniSystemModuleAssemblyPartNumber,
|
|
juniSystemModuleAssemblyRev,
|
|
juniSystemModulePhysicalIndex,
|
|
juniSystemModuleSoftwareSupport,
|
|
juniSystemModuleRedundancySupport,
|
|
juniSystemModuleLevelSpan,
|
|
|
|
juniSystemModuleSoftwareVersion,
|
|
juniSystemModuleCpuUtilPct,
|
|
juniSystemModuleMemUtilPct,
|
|
juniSystemModuleAdminStatus,
|
|
juniSystemModuleControl,
|
|
juniSystemModuleBootReleaseFile,
|
|
juniSystemModuleBootBackupReleaseFile,
|
|
|
|
juniSystemModuleRedundancyGroupId,
|
|
juniSystemModuleRedundancySpare,
|
|
juniSystemModuleRedundancyAssociatedSlot,
|
|
juniSystemModuleRedundancyLockout,
|
|
juniSystemModuleRedundancyRevertControl,
|
|
juniSystemModuleRedundancyRevertTime }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"A collection of management objects that provide system module
|
|
information in a Juniper E-series product."
|
|
::= { juniSystemGroups 15 } -- JUNOSe 6.0
|
|
|
|
juniSystemUtilizationGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemUtilizationMaxCapacity,
|
|
juniSystemUtilizationCurrentValue,
|
|
juniSystemUtilizationThresholdRising,
|
|
juniSystemUtilizationThresholdFalling,
|
|
juniSystemUtilizationHoldDownTime,
|
|
juniSystemUtilizationThresholdDirection,
|
|
juniSystemCpuUtilizationTaskName,
|
|
juniSystemCpuUtilizationInvoked,
|
|
juniSystemCpuUtilizationInvokationPerSec,
|
|
juniSystemCpuUtilizationTotalRunningTime,
|
|
juniSystemCpuUtilizationPercentageRunningTime,
|
|
juniSystemCpuUtilizationAverageTimePerInvokation,
|
|
juniSystemCpuUtilizationFiveSecondUtilization,
|
|
juniSystemCpuUtilizationOneMinuteUtilization,
|
|
juniSystemCpuUtilizationFiveMinuteUtilization,
|
|
juniSystemCpuUtilizationNumberOfInstances }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects providing system resource
|
|
utilization information and notification control for a Juniper E-series
|
|
product."
|
|
::= { juniSystemGroups 16 } -- JUNOSe 7.3
|
|
|
|
juniSystemModuleGroup3 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemMaxSlotNumber,
|
|
juniSystemMaxModulesPerSlot,
|
|
|
|
juniSystemSlotStatus,
|
|
juniSystemSlotType,
|
|
|
|
juniSystemModuleOperStatus,
|
|
juniSystemModuleDisableReason,
|
|
juniSystemModuleLastChange,
|
|
juniSystemModuleCurrentType,
|
|
juniSystemModuleExpectedType,
|
|
juniSystemModuleDescr,
|
|
juniSystemModuleSlotSpan,
|
|
juniSystemModulePortCount,
|
|
juniSystemModuleSerialNumber,
|
|
juniSystemModuleAssemblyPartNumber,
|
|
juniSystemModuleAssemblyRev,
|
|
juniSystemModulePhysicalIndex,
|
|
juniSystemModuleSoftwareSupport,
|
|
juniSystemModuleRedundancySupport,
|
|
juniSystemModuleLevelSpan,
|
|
|
|
juniSystemModuleSoftwareVersion,
|
|
juniSystemModuleCpuUtilPct,
|
|
juniSystemModuleMemUtilPct,
|
|
juniSystemModuleAdminStatus,
|
|
juniSystemModuleControl,
|
|
juniSystemModuleBootReleaseFile,
|
|
juniSystemModuleBootBackupReleaseFile,
|
|
juniSystemModuleCpuFiveSecUtilPct,
|
|
juniSystemModuleCpuOneMinAvgPct,
|
|
juniSystemModuleCpuFiveMinAvgPct,
|
|
|
|
juniSystemModuleRedundancyGroupId,
|
|
juniSystemModuleRedundancySpare,
|
|
juniSystemModuleRedundancyAssociatedSlot,
|
|
juniSystemModuleRedundancyLockout,
|
|
juniSystemModuleRedundancyRevertControl,
|
|
juniSystemModuleRedundancyRevertTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects that provide system module
|
|
information in a Juniper E-series product."
|
|
::= { juniSystemGroups 17 } -- JUNOSe 8.0
|
|
|
|
juniSystemIssuGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniSystemIssuState,
|
|
juniSystemIssuArmedReleaseFile,
|
|
juniSystemIssuRunningReleaseFile,
|
|
juniSystemIssuStatus,
|
|
|
|
juniSystemIssuCriteriaDescription,
|
|
juniSystemIssuCriteriaStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of management objects that provide ISSU related
|
|
information in a Juniper E-series product."
|
|
::= { juniSystemGroups 18 } -- JUNOSe 9.0
|
|
|
|
juniSystemNotificationGroup3 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
juniSystemHighMemUtil,
|
|
juniSystemAbatedMemUtil,
|
|
juniSystemModuleOperStatusChange,
|
|
juniSystemPowerStatusChange,
|
|
juniSystemFanStatusChange,
|
|
juniSystemTempStatusChange,
|
|
juniSystemTempProtectionStatusChange,
|
|
juniSystemReloadCommand,
|
|
juniSystemUtilizationThreshold,
|
|
juniSystemIssuStateChange }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of notifications for system events in a Juniper E-series
|
|
product."
|
|
::= { juniSystemGroups 19 } -- JUNOSe 9.0
|
|
|
|