- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
628 lines
21 KiB
Text
628 lines
21 KiB
Text
ETHER-WIS DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Gauge32, transmission
|
|
FROM SNMPv2-SMI
|
|
ifIndex
|
|
FROM IF-MIB
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
sonetMediumStuff2, sonetSectionStuff2,
|
|
sonetLineStuff2, sonetFarEndLineStuff2,
|
|
sonetPathStuff2, sonetFarEndPathStuff2,
|
|
sonetMediumType, sonetMediumLineCoding,
|
|
sonetMediumLineType, sonetMediumCircuitIdentifier,
|
|
sonetMediumLoopbackConfig, sonetSESthresholdSet,
|
|
sonetPathCurrentWidth
|
|
FROM SONET-MIB;
|
|
|
|
etherWisMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200309190000Z" -- September 19, 2003
|
|
ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
|
|
Working Group"
|
|
CONTACT-INFO
|
|
"WG charter:
|
|
http://www.ietf.org/html.charters/hubmib-charter.html
|
|
|
|
Mailing Lists:
|
|
General Discussion: hubmib@ietf.org <mailto:hubmib@ietf.org>
|
|
To Subscribe: hubmib-request@ietf.org <mailto:hubmib-request@ietf.org>
|
|
In Body: subscribe your_email_address
|
|
|
|
Chair: Dan Romascanu
|
|
Postal: Avaya Inc.
|
|
Atidim Technology Park, Bldg. 3
|
|
Tel Aviv 61131
|
|
Israel
|
|
Tel: +972 3 645 8414
|
|
E-mail: dromasca@avaya.com <mailto:dromasca@avaya.com>
|
|
|
|
Editor: C. M. Heard
|
|
Postal: 600 Rainbow Dr. #141
|
|
Mountain View, CA 94041-2542
|
|
USA
|
|
Tel: +1 650-964-8391
|
|
E-mail: heard@pobox.com <mailto:heard@pobox.com>"
|
|
|
|
DESCRIPTION
|
|
"The objects in this MIB module are used in conjunction
|
|
with objects in the SONET-MIB and the MAU-MIB to manage
|
|
the Ethernet WAN Interface Sublayer (WIS).
|
|
|
|
The following reference is used throughout this MIB module:
|
|
|
|
[IEEE 802.3 Std] refers to:
|
|
IEEE Std 802.3, 2000 Edition: 'IEEE Standard for
|
|
Information technology - Telecommunications and
|
|
information exchange between systems - Local and
|
|
metropolitan area networks - Specific requirements -
|
|
Part 3: Carrier sense multiple access with collision
|
|
detection (CSMA/CD) access method and physical layer
|
|
specifications', as amended by IEEE Std 802.3ae-2002,
|
|
'IEEE Standard for Carrier Sense Multiple Access with
|
|
Collision Detection (CSMA/CD) Access Method and
|
|
Physical Layer Specifications - Media Access Control
|
|
(MAC) Parameters, Physical Layer and Management
|
|
Parameters for 10 Gb/s Operation', 30 August 2002.
|
|
|
|
Of particular interest are Clause 50, 'WAN Interface
|
|
Sublayer (WIS), type 10GBASE-W', Clause 30, '10Mb/s,
|
|
100Mb/s, 1000Mb/s, and 10Gb/s MAC Control, and Link
|
|
Aggregation Management', and Clause 45, 'Management
|
|
Data Input/Output (MDIO) Interface'.
|
|
|
|
Copyright (C) The Internet Society (2003). This version
|
|
of this MIB module is part of RFC 3637 </rfcs/rfc3637.html>; see the RFC
|
|
itself for full legal notices."
|
|
|
|
REVISION "200309190000Z" -- September 19, 2003
|
|
DESCRIPTION "Initial version, published as RFC 3637 </rfcs/rfc3637.html>."
|
|
|
|
::= { transmission 134 }
|
|
|
|
-- The main sections of the module
|
|
|
|
etherWisObjects OBJECT IDENTIFIER ::= { etherWisMIB 1 }
|
|
|
|
etherWisObjectsPath OBJECT IDENTIFIER ::= { etherWisMIB 2 }
|
|
|
|
etherWisConformance OBJECT IDENTIFIER ::= { etherWisMIB 3 }
|
|
|
|
-- groups in the Ethernet WIS MIB module
|
|
|
|
etherWisDevice OBJECT IDENTIFIER ::= { etherWisObjects 1 }
|
|
|
|
etherWisSection OBJECT IDENTIFIER ::= { etherWisObjects 2 }
|
|
|
|
etherWisPath OBJECT IDENTIFIER ::= { etherWisObjectsPath 1 }
|
|
|
|
etherWisFarEndPath OBJECT IDENTIFIER ::= { etherWisObjectsPath 2 }
|
|
|
|
-- The Device group
|
|
|
|
-- These objects provide WIS extensions to
|
|
-- the SONET-MIB Medium Group.
|
|
|
|
etherWisDeviceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EtherWisDeviceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for Ethernet WIS devices"
|
|
::= { etherWisDevice 1 }
|
|
|
|
etherWisDeviceEntry OBJECT-TYPE
|
|
SYNTAX EtherWisDeviceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Ethernet WIS device table. For each
|
|
instance of this object there MUST be a corresponding
|
|
instance of sonetMediumEntry."
|
|
INDEX { ifIndex }
|
|
::= { etherWisDeviceTable 1 }
|
|
|
|
EtherWisDeviceEntry ::=
|
|
SEQUENCE {
|
|
etherWisDeviceTxTestPatternMode INTEGER,
|
|
etherWisDeviceRxTestPatternMode INTEGER,
|
|
etherWisDeviceRxTestPatternErrors Gauge32
|
|
}
|
|
|
|
etherWisDeviceTxTestPatternMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
squareWave(2),
|
|
prbs31(3),
|
|
mixedFrequency(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable controls the transmit test pattern mode.
|
|
The value none(1) puts the the WIS transmit path into
|
|
the normal operating mode. The value squareWave(2) puts
|
|
the WIS transmit path into the square wave test pattern
|
|
mode described in [IEEE 802.3 Std.] subclause 50.3.8.1.
|
|
The value prbs31(3) puts the WIS transmit path into the
|
|
PRBS31 test pattern mode described in [IEEE 802.3 Std.]
|
|
subclause 50.3.8.2. The value mixedFrequency(4) puts the
|
|
WIS transmit path into the mixed frequency test pattern
|
|
mode described in [IEEE 802.3 Std.] subclause 50.3.8.3.
|
|
Any attempt to set this object to a value other than
|
|
none(1) when the corresponding instance of ifAdminStatus
|
|
has the value up(1) MUST be rejected with the error
|
|
inconsistentValue, and any attempt to set the corresponding
|
|
instance of ifAdminStatus to the value up(1) when an
|
|
instance of this object has a value other than none(1)
|
|
MUST be rejected with the error inconsistentValue."
|
|
REFERENCE
|
|
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
|
|
checker, 45.2.2.6, 10G WIS control 2 register (2.7), and
|
|
45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
|
|
::= { etherWisDeviceEntry 1 }
|
|
|
|
etherWisDeviceRxTestPatternMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
prbs31(3),
|
|
mixedFrequency(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"This variable controls the receive test pattern mode.
|
|
The value none(1) puts the the WIS receive path into the
|
|
normal operating mode. The value prbs31(3) puts the WIS
|
|
receive path into the PRBS31 test pattern mode described
|
|
in [IEEE 802.3 Std.] subclause 50.3.8.2. The value
|
|
mixedFrequency(4) puts the WIS receive path into the mixed
|
|
frequency test pattern mode described in [IEEE 802.3 Std.]
|
|
subclause 50.3.8.3. Any attempt to set this object to a
|
|
value other than none(1) when the corresponding instance
|
|
of ifAdminStatus has the value up(1) MUST be rejected with
|
|
the error inconsistentValue, and any attempt to set the
|
|
corresponding instance of ifAdminStatus to the value up(1)
|
|
when an instance of this object has a value other than
|
|
none(1) MUST be rejected with the error inconsistentValue."
|
|
REFERENCE
|
|
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
|
|
checker, 45.2.2.6, 10G WIS control 2 register (2.7), and
|
|
45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
|
|
::= { etherWisDeviceEntry 2 }
|
|
|
|
etherWisDeviceRxTestPatternErrors OBJECT-TYPE
|
|
SYNTAX Gauge32 ( 0..65535 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object counts the number of errors detected when the
|
|
WIS receive path is operating in the PRBS31 test pattern
|
|
mode. It is reset to zero when the WIS receive path
|
|
initially enters that mode, and it increments each time
|
|
the PRBS pattern checker detects an error as described in
|
|
[IEEE 802.3 Std.] subclause 50.3.8.2 unless its value is
|
|
65535, in which case it remains unchanged. This object is
|
|
writeable so that it may be reset upon explicit request
|
|
of a command generator application while the WIS receive
|
|
path continues to operate in PRBS31 test pattern mode."
|
|
REFERENCE
|
|
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
|
|
checker, 45.2.2.7.2, PRBS31 pattern testing ability
|
|
(2.8.1), and 45.2.2.8, 10G WIS test pattern error counter
|
|
register (2.9)."
|
|
::= { etherWisDeviceEntry 3 }
|
|
|
|
-- The Section group
|
|
|
|
-- These objects provide WIS extensions to
|
|
-- the SONET-MIB Section Group.
|
|
|
|
etherWisSectionCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EtherWisSectionCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for the current state of Ethernet WIS sections."
|
|
::= { etherWisSection 1 }
|
|
|
|
etherWisSectionCurrentEntry OBJECT-TYPE
|
|
SYNTAX EtherWisSectionCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the etherWisSectionCurrentTable. For each
|
|
instance of this object there MUST be a corresponding
|
|
instance of sonetSectionCurrentEntry."
|
|
INDEX { ifIndex }
|
|
::= { etherWisSectionCurrentTable 1 }
|
|
|
|
EtherWisSectionCurrentEntry ::=
|
|
SEQUENCE {
|
|
etherWisSectionCurrentJ0Transmitted OCTET STRING,
|
|
etherWisSectionCurrentJ0Received OCTET STRING
|
|
}
|
|
|
|
etherWisSectionCurrentJ0Transmitted OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the 16-octet section trace message that
|
|
is transmitted in the J0 byte. The value SHOULD
|
|
be '89'h followed by fifteen octets of '00'h
|
|
(or some cyclic shift thereof) when the section
|
|
trace function is not used, and the implementation
|
|
SHOULD use that value (or a cyclic shift thereof)
|
|
as a default if no other value has been set."
|
|
REFERENCE
|
|
"[IEEE 802.3 Std.], 30.8.1.1.8, aJ0ValueTX."
|
|
::= { etherWisSectionCurrentEntry 1 }
|
|
|
|
etherWisSectionCurrentJ0Received OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the 16-octet section trace message that
|
|
was most recently received in the J0 byte."
|
|
REFERENCE
|
|
"[IEEE 802.3 Std.], 30.8.1.1.9, aJ0ValueRX."
|
|
::= { etherWisSectionCurrentEntry 2 }
|
|
|
|
-- The Path group
|
|
|
|
-- These objects provide WIS extensions to
|
|
-- the SONET-MIB Path Group.
|
|
|
|
etherWisPathCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EtherWisPathCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for the current state of Ethernet WIS paths."
|
|
::= { etherWisPath 1 }
|
|
|
|
etherWisPathCurrentEntry OBJECT-TYPE
|
|
SYNTAX EtherWisPathCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the etherWisPathCurrentTable. For each
|
|
instance of this object there MUST be a corresponding
|
|
instance of sonetPathCurrentEntry."
|
|
INDEX { ifIndex }
|
|
::= { etherWisPathCurrentTable 1 }
|
|
|
|
EtherWisPathCurrentEntry ::=
|
|
SEQUENCE {
|
|
etherWisPathCurrentStatus BITS,
|
|
etherWisPathCurrentJ1Transmitted OCTET STRING,
|
|
etherWisPathCurrentJ1Received OCTET STRING
|
|
}
|
|
|
|
etherWisPathCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
etherWisPathLOP(0),
|
|
etherWisPathAIS(1),
|
|
etherWisPathPLM(2),
|
|
etherWisPathLCD(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the current status of the
|
|
path payload with a bit map that can indicate multiple
|
|
defects at once. The bit positions are assigned as
|
|
follows:
|
|
|
|
etherWisPathLOP(0)
|
|
This bit is set to indicate that an
|
|
LOP-P (Loss of Pointer - Path) defect
|
|
is being experienced. Note: when this
|
|
bit is set, sonetPathSTSLOP MUST be set
|
|
in the corresponding instance of
|
|
sonetPathCurrentStatus.
|
|
|
|
etherWisPathAIS(1)
|
|
This bit is set to indicate that an
|
|
AIS-P (Alarm Indication Signal - Path)
|
|
defect is being experienced. Note: when
|
|
this bit is set, sonetPathSTSAIS MUST be
|
|
set in the corresponding instance of
|
|
sonetPathCurrentStatus.
|
|
|
|
etherWisPathPLM(1)
|
|
This bit is set to indicate that a
|
|
PLM-P (Payload Label Mismatch - Path)
|
|
defect is being experienced. Note: when
|
|
this bit is set, sonetPathSignalLabelMismatch
|
|
MUST be set in the corresponding instance of
|
|
sonetPathCurrentStatus.
|
|
|
|
etherWisPathLCD(3)
|
|
This bit is set to indicate that an
|
|
LCD-P (Loss of Codegroup Delination - Path)
|
|
defect is being experienced. Since this
|
|
defect is detected by the PCS and not by
|
|
the path layer itself, there is no
|
|
corresponding bit in sonetPathCurrentStatus."
|
|
REFERENCE
|
|
"[IEEE 802.3 Std.], 30.8.1.1.18, aPathStatus."
|
|
::= { etherWisPathCurrentEntry 1 }
|
|
|
|
etherWisPathCurrentJ1Transmitted OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the 16-octet path trace message that
|
|
is transmitted in the J1 byte. The value SHOULD
|
|
be '89'h followed by fifteen octets of '00'h
|
|
(or some cyclic shift thereof) when the path
|
|
trace function is not used, and the implementation
|
|
SHOULD use that value (or a cyclic shift thereof)
|
|
as a default if no other value has been set."
|
|
REFERENCE
|
|
"[IEEE 802.3 Std.], 30.8.1.1.23, aJ1ValueTX."
|
|
::= { etherWisPathCurrentEntry 2 }
|
|
|
|
etherWisPathCurrentJ1Received OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the 16-octet path trace message that
|
|
was most recently received in the J1 byte."
|
|
REFERENCE
|
|
"[IEEE 802.3 Std.], 30.8.1.1.24, aJ1ValueRX."
|
|
::= { etherWisPathCurrentEntry 3 }
|
|
|
|
-- The Far End Path group
|
|
|
|
-- These objects provide WIS extensions to
|
|
-- the SONET-MIB Far End Path Group.
|
|
|
|
etherWisFarEndPathCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EtherWisFarEndPathCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table for the current far-end state of Ethernet WIS
|
|
paths."
|
|
::= { etherWisFarEndPath 1 }
|
|
|
|
etherWisFarEndPathCurrentEntry OBJECT-TYPE
|
|
SYNTAX EtherWisFarEndPathCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the etherWisFarEndPathCurrentTable. For each
|
|
instance of this object there MUST be a corresponding
|
|
instance of sonetFarEndPathCurrentEntry."
|
|
INDEX { ifIndex }
|
|
::= { etherWisFarEndPathCurrentTable 1 }
|
|
|
|
EtherWisFarEndPathCurrentEntry ::=
|
|
SEQUENCE {
|
|
etherWisFarEndPathCurrentStatus BITS
|
|
}
|
|
|
|
etherWisFarEndPathCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
etherWisFarEndPayloadDefect(0),
|
|
etherWisFarEndServerDefect(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the current status at the
|
|
far end of the path using a bit map that can indicate
|
|
multiple defects at once. The bit positions are
|
|
assigned as follows:
|
|
|
|
etherWisFarEndPayloadDefect(0)
|
|
A far end payload defect (i.e., far end
|
|
PLM-P or LCD-P) is currently being signaled
|
|
in G1 bits 5-7.
|
|
|
|
etherWisFarEndServerDefect(1)
|
|
A far end server defect (i.e., far end
|
|
LOP-P or AIS-P) is currently being signaled
|
|
in G1 bits 5-7. Note: when this bit is set,
|
|
sonetPathSTSRDI MUST be set in the corresponding
|
|
instance of sonetPathCurrentStatus."
|
|
REFERENCE
|
|
"[IEEE 802.3 Std.], 30.8.1.1.25, aFarEndPathStatus."
|
|
::= { etherWisFarEndPathCurrentEntry 1 }
|
|
|
|
--
|
|
-- Conformance Statements
|
|
--
|
|
|
|
etherWisGroups OBJECT IDENTIFIER ::= { etherWisConformance 1 }
|
|
|
|
etherWisCompliances OBJECT IDENTIFIER ::= { etherWisConformance 2 }
|
|
|
|
-- Object Groups
|
|
|
|
etherWisDeviceGroupBasic OBJECT-GROUP
|
|
OBJECTS {
|
|
etherWisDeviceTxTestPatternMode,
|
|
etherWisDeviceRxTestPatternMode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that support test
|
|
features required of all WIS devices."
|
|
::= { etherWisGroups 1 }
|
|
|
|
etherWisDeviceGroupExtra OBJECT-GROUP
|
|
OBJECTS {
|
|
etherWisDeviceRxTestPatternErrors
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that support
|
|
optional WIS device test features."
|
|
::= { etherWisGroups 2 }
|
|
|
|
etherWisSectionGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
etherWisSectionCurrentJ0Transmitted,
|
|
etherWisSectionCurrentJ0Received
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that provide
|
|
required information about a WIS section."
|
|
::= { etherWisGroups 3 }
|
|
|
|
etherWisPathGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
etherWisPathCurrentStatus,
|
|
etherWisPathCurrentJ1Transmitted,
|
|
etherWisPathCurrentJ1Received
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that provide
|
|
required information about a WIS path."
|
|
::= { etherWisGroups 4 }
|
|
|
|
etherWisFarEndPathGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
etherWisFarEndPathCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that provide required
|
|
information about the far end of a WIS path."
|
|
::= { etherWisGroups 5 }
|
|
|
|
-- Compliance Statements
|
|
|
|
etherWisCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for interfaces that include
|
|
the Ethernet WIS. Compliance with the following
|
|
external compliance statements is prerequisite:
|
|
|
|
MIB Module Compliance Statement
|
|
---------- --------------------
|
|
IF-MIB ifCompliance3
|
|
IF-INVERTED-STACK-MIB ifInvCompliance
|
|
EtherLike-MIB dot3Compliance2
|
|
MAU-MIB mauModIfCompl3"
|
|
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
etherWisDeviceGroupBasic,
|
|
etherWisSectionGroup,
|
|
etherWisPathGroup,
|
|
etherWisFarEndPathGroup
|
|
}
|
|
|
|
OBJECT etherWisDeviceTxTestPatternMode
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
squareWave(2),
|
|
mixedFrequency(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support for values other than none(1),
|
|
squareWave(2), and mixedFrequency(4)
|
|
is not required."
|
|
|
|
OBJECT etherWisDeviceRxTestPatternMode
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
mixedFrequency(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support for values other than none(1)
|
|
and mixedFrequency(4) is not required."
|
|
|
|
GROUP etherWisDeviceGroupExtra
|
|
DESCRIPTION
|
|
"Implementation of this group, along with support for
|
|
the value prbs31(3) for etherWisDeviceTxTestPatternMode
|
|
and etherWisDeviceRxTestPatternMode, is necessary if the
|
|
optional PRBS31 test pattern mode is to be supported."
|
|
|
|
OBJECT etherWisDeviceRxTestPatternErrors
|
|
WRITE-SYNTAX Gauge32 ( 0 )
|
|
DESCRIPTION
|
|
"An implementation is not required to
|
|
allow values other than zero to be
|
|
written to this object."
|
|
|
|
MODULE SONET-MIB
|
|
MANDATORY-GROUPS {
|
|
sonetMediumStuff2,
|
|
sonetSectionStuff2,
|
|
sonetLineStuff2,
|
|
sonetFarEndLineStuff2,
|
|
sonetPathStuff2,
|
|
sonetFarEndPathStuff2
|
|
}
|
|
|
|
OBJECT sonetMediumType
|
|
SYNTAX INTEGER {
|
|
sonet(1)
|
|
}
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required, nor is support
|
|
for any value other than sonet(1)."
|
|
|
|
OBJECT sonetMediumLineCoding
|
|
SYNTAX INTEGER {
|
|
sonetMediumNRZ(4)
|
|
}
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required, nor is support
|
|
for any value other than sonetMediumNRZ(4)."
|
|
|
|
OBJECT sonetMediumLineType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT sonetMediumCircuitIdentifier
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT sonetMediumLoopbackConfig
|
|
SYNTAX BITS {
|
|
sonetNoLoop(0),
|
|
sonetFacilityLoop(1)
|
|
}
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required, nor is support for values
|
|
other than sonetNoLoop(0) and sonetFacilityLoop(1)."
|
|
|
|
OBJECT sonetSESthresholdSet
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required, and only one
|
|
of the enumerated values need be supported."
|
|
|
|
OBJECT sonetPathCurrentWidth
|
|
SYNTAX INTEGER {
|
|
sts192cSTM64(6)
|
|
}
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required, nor is support
|
|
for any value other than sts192cSTM64(6)."
|
|
|
|
::= { etherWisCompliances 1 }
|
|
|
|
END
|