- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
4533 lines
152 KiB
Text
4533 lines
152 KiB
Text
-- EDS MIB file for all products
|
|
-- Larry Wood 12/15/11 v1.2
|
|
-- Added device types EDS0070, 71, 80, 82, 83, 85, 90, 91, 92
|
|
-- Removed range value in text for TrapHighThreshold, TrapLowThreshold and TrapHysteresis
|
|
--
|
|
-- Larry Wood 12/28/11 v1.3
|
|
-- Updated device types EDS0090, 91, 92
|
|
--
|
|
|
|
-- Larry Wood 4/9/12 v1.5
|
|
-- Added nodes for Wireless Trap table
|
|
--
|
|
-- Larry Wood 6/26/12 v1.6
|
|
-- Added DS28EA00
|
|
|
|
--
|
|
|
|
-- Larry Wood 8/20/12 v1.7
|
|
-- Added EDS0050
|
|
--
|
|
-- Larry Wood 11/29/12 v1.8
|
|
-- Added EDS2030
|
|
--
|
|
EDS-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
enterprises
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
DisplayString
|
|
FROM RFC1213-MIB;
|
|
|
|
|
|
--Embedded Data Systems, Inc. enterprise OID
|
|
edsMain OBJECT IDENTIFIER ::= { enterprises 31440 }
|
|
|
|
--Enterprise company branch.
|
|
edsEnterprise OBJECT IDENTIFIER ::= { edsMain 1 }
|
|
|
|
eCompanyName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Company owner of this enterprise number"
|
|
::= { edsEnterprise 1 }
|
|
|
|
eProductName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Name of this product"
|
|
::= { edsEnterprise 2 }
|
|
|
|
eMIBVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Version of the MIB file in the product"
|
|
::= { edsEnterprise 3 }
|
|
|
|
eFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Firmware version"
|
|
::= { edsEnterprise 4 }
|
|
|
|
eFirmwareDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Date of firmware"
|
|
::= { edsEnterprise 5 }
|
|
|
|
--device trap table
|
|
dTrap OBJECT IDENTIFIER ::= { edsMain 2 }
|
|
dTrapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF dTrapEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
::= { dTrap 1 }
|
|
|
|
dTrapEntry OBJECT-TYPE
|
|
SYNTAX dTrapEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
INDEX {
|
|
dTrapIndex
|
|
}
|
|
::= { dTrapTable 1 }
|
|
|
|
dTrapEntry ::= SEQUENCE {
|
|
dTrapIndex
|
|
INTEGER,
|
|
dTrapEnable
|
|
INTEGER,
|
|
dTrapIP
|
|
IpAddress,
|
|
dTrapCommunity
|
|
INTEGER
|
|
}
|
|
|
|
dTrapIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index of table."
|
|
::= { dTrapEntry 1 }
|
|
|
|
dTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Zero disables the trap, one enables it."
|
|
::= { dTrapEntry 2 }
|
|
|
|
dTrapIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Address to send trap to."
|
|
::= { dTrapEntry 3 }
|
|
|
|
dTrapCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Community string to send with trap message."
|
|
::= { dTrapEntry 4 }
|
|
|
|
|
|
--dTrapDeviceTable
|
|
dTrapDeviceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF dTrapDeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
::= { dTrap 2 }
|
|
|
|
dTrapDeviceEntry OBJECT-TYPE
|
|
SYNTAX dTrapDeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
INDEX {
|
|
dTrapDeviceIndex
|
|
}
|
|
::= { dTrapDeviceTable 1 }
|
|
|
|
dTrapDeviceEntry ::= SEQUENCE {
|
|
dTrapDeviceIndex
|
|
INTEGER,
|
|
dTrapDeviceEnable
|
|
INTEGER,
|
|
dTrapDeviceSendPointer
|
|
INTEGER,
|
|
dTrapDeviceROM
|
|
OCTET STRING,
|
|
dTrapDeviceVariable
|
|
INTEGER,
|
|
dTrapDeviceHighThreshold
|
|
DisplayString,
|
|
dTrapDeviceLowThreshold
|
|
DisplayString,
|
|
dTrapDeviceHysteresis
|
|
DisplayString
|
|
}
|
|
|
|
dTrapDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index of table. Traps are sent with this OID followed by the index
|
|
number of the table entry that generated the trap. For example, if
|
|
the values at index 5 of this table generated a trap, the name of the
|
|
trap would be .iso.org.dod.internet.private.enterprises.edsMain.dTrap.
|
|
dTrapDeviceTable.dTrapDeviceEntry.dTrapDeviceIndex.5. The numeric
|
|
value is 1.3.6.1.4.1.31440.2.2.1.1.5. An integer value is sent with the
|
|
trap, which indicates what state change caused the trap. Using the
|
|
dTrapDeviceHighThreshold, dTrapDeviceLowThreshold and
|
|
dTrapDeviceHysteresis values, 3 windows are created. Transitions between
|
|
these windows generates a trap. The integer value indicates which
|
|
transition caused the trap as follows:
|
|
1 -> middle to high window transition
|
|
2 -> high to middle window transition
|
|
3 -> middle to low window transition
|
|
4 -> low to middle window transition
|
|
|
|
Note the following when programming traps:
|
|
1) Programming the HighThreshold lower than the LowThreshold is
|
|
invalid and will disable trap generation.
|
|
2) dTrapDeviceHysteresis values are not checked for validity, use them
|
|
with caution.
|
|
3) A trap must be enabled to be sent.
|
|
4) The dTrapDeviceROM must be set to an active device or a trap
|
|
will not be sent.
|
|
5) The health of the 1-wire device must be greater than 0 or no trap will
|
|
be sent.
|
|
6) The dTrapDeviceVariable must be valid. For exmaple, the DS18S20 has 3
|
|
variables as follows: Temperature, UserByte1 and UserByte2. These are
|
|
numbered 0, 1 and 2 respectively. A setting of 3 or above is invalid.
|
|
7) The dTrapTable must be programmed correctly for traps to be sent.
|
|
The respective table entry must be enabled and have a valid IP address.
|
|
Community strings are not used by the SNMP server."
|
|
|
|
|
|
::= { dTrapDeviceEntry 1 }
|
|
|
|
dTrapDeviceEnable OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Zero disables the trap, one enables it."
|
|
::= { dTrapDeviceEntry 2 }
|
|
|
|
dTrapDeviceSendPointer OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Indicates which entry in the Trap Table to use to determine where
|
|
to send the trap. The Trap Table contains the destination IP address."
|
|
::= { dTrapDeviceEntry 3 }
|
|
|
|
dTrapDeviceROM OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Device ROM code to base sending trap message on."
|
|
::= { dTrapDeviceEntry 4 }
|
|
|
|
dTrapDeviceVariable OBJECT-TYPE
|
|
SYNTAX INTEGER (0..99)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Number of the variable to reference, as listed in the Devices section
|
|
of this MIB. For example, the DS2406 has 9 items, which would be numbered 0 - 8.
|
|
So if dTrapDeviceVariable were set to 0 it would refer to owDS2406PIOAFlipFlop,
|
|
if it were set to 3 it would refer to owDS2406PIOBLevel."
|
|
::= { dTrapDeviceEntry 5 }
|
|
|
|
dTrapDeviceHighThreshold OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "A trap will be generated when the variable is greater than this value or
|
|
it is less than or equal to this value - dTrapDeviceHysteresis. This number
|
|
may be positive or negative and may contain a decimal point."
|
|
::= { dTrapDeviceEntry 6 }
|
|
|
|
dTrapDeviceLowThreshold OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "A trap will be generated when the variable is less than this value or
|
|
it is greater than or equal to this value + dTrapDeviceHysteresis. This number
|
|
may be positive or negative and may contain a decimal point."
|
|
::= { dTrapDeviceEntry 7 }
|
|
|
|
dTrapDeviceHysteresis OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This value is used to limit repeated trap sends due to a value hovering around
|
|
a threshold. If it is not used it should be set to zero. This number may be positive
|
|
or negative and may contain a decimal point."
|
|
::= { dTrapDeviceEntry 8 }
|
|
|
|
|
|
|
|
--1-wire devices branch.
|
|
owDevices OBJECT IDENTIFIER ::= { edsMain 10 }
|
|
|
|
--Device type table (conceptual).
|
|
owDeviceTypes OBJECT IDENTIFIER ::= { owDevices 1 }
|
|
|
|
owNone OBJECT IDENTIFIER ::= { owDeviceTypes 0 }
|
|
owUnknown OBJECT IDENTIFIER ::= { owDeviceTypes 1 }
|
|
owDS2406 OBJECT IDENTIFIER ::= { owDeviceTypes 2 }
|
|
owDS18B20 OBJECT IDENTIFIER ::= { owDeviceTypes 3 }
|
|
owDS18S20 OBJECT IDENTIFIER ::= { owDeviceTypes 4 }
|
|
owDS2438 OBJECT IDENTIFIER ::= { owDeviceTypes 5 }
|
|
owDS2423 OBJECT IDENTIFIER ::= { owDeviceTypes 6 }
|
|
owDS2408 OBJECT IDENTIFIER ::= { owDeviceTypes 7 }
|
|
owDS2450 OBJECT IDENTIFIER ::= { owDeviceTypes 8 }
|
|
owEDS0064 OBJECT IDENTIFIER ::= { owDeviceTypes 9 }
|
|
owEDS0065 OBJECT IDENTIFIER ::= { owDeviceTypes 10 }
|
|
owEDS0066 OBJECT IDENTIFIER ::= { owDeviceTypes 11 }
|
|
owEDS0067 OBJECT IDENTIFIER ::= { owDeviceTypes 12 }
|
|
owEDS0068 OBJECT IDENTIFIER ::= { owDeviceTypes 13 }
|
|
owEDS0069 OBJECT IDENTIFIER ::= { owDeviceTypes 14 }
|
|
owEDS0070 OBJECT IDENTIFIER ::= { owDeviceTypes 15 }
|
|
owEDS0071 OBJECT IDENTIFIER ::= { owDeviceTypes 16 }
|
|
owEDS0080 OBJECT IDENTIFIER ::= { owDeviceTypes 17 }
|
|
owEDS0082 OBJECT IDENTIFIER ::= { owDeviceTypes 18 }
|
|
owEDS0083 OBJECT IDENTIFIER ::= { owDeviceTypes 19 }
|
|
owEDS0085 OBJECT IDENTIFIER ::= { owDeviceTypes 20 }
|
|
owEDS0090 OBJECT IDENTIFIER ::= { owDeviceTypes 21 }
|
|
owEDS0091 OBJECT IDENTIFIER ::= { owDeviceTypes 22 }
|
|
owEDS0092 OBJECT IDENTIFIER ::= { owDeviceTypes 23 }
|
|
owDS28EA00 OBJECT IDENTIFIER ::= { owDeviceTypes 24 }
|
|
owEDS0050 OBJECT IDENTIFIER ::= { owDeviceTypes 25 }
|
|
|
|
owDeviceInfo OBJECT IDENTIFIER ::= { owDevices 2 }
|
|
|
|
owDeviceNumActive OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number of currently active 1-wire devices. A device
|
|
is active if it's health is non-zero."
|
|
::= { owDeviceInfo 1 }
|
|
|
|
owDeviceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OwDeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
::= { owDevices 3 }
|
|
|
|
owDeviceEntry OBJECT-TYPE
|
|
SYNTAX OwDeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owDeviceTable 1 }
|
|
|
|
OwDeviceEntry ::= SEQUENCE {
|
|
owDeviceIndex
|
|
INTEGER,
|
|
owDeviceType
|
|
INTEGER,
|
|
owDeviceName
|
|
DisplayString,
|
|
owDeviceDescription
|
|
DisplayString,
|
|
owDeviceFamily
|
|
INTEGER,
|
|
owDeviceROM
|
|
OCTET STRING,
|
|
owDeviceHealth
|
|
INTEGER
|
|
}
|
|
|
|
owDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index of table."
|
|
::= { owDeviceEntry 1 }
|
|
|
|
owDeviceType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "An indication of the device type. This is the
|
|
last OID number to the owDeviceTypes group pointing
|
|
to the name of the device. The corresponding
|
|
device table will contain the specific information
|
|
from the device. For example: if this entry is
|
|
2 (owDS2406) then the table owDS2406Table, at
|
|
the appropriate index, will contain the data
|
|
from the device."
|
|
::= { owDeviceEntry 2 }
|
|
|
|
owDeviceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Text description of the device."
|
|
::= { owDeviceEntry 3 }
|
|
|
|
owDeviceDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Text description of the device."
|
|
::= { owDeviceEntry 4 }
|
|
|
|
owDeviceFamily OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Family number as read from 1-wire device."
|
|
::= { owDeviceEntry 5 }
|
|
|
|
owDeviceROM OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Entire ROM code as read from 1-wire device (includes
|
|
family number and CRC). Always 16 bytes long."
|
|
::= { owDeviceEntry 6 }
|
|
|
|
owDeviceHealth OBJECT-TYPE
|
|
SYNTAX INTEGER (0..8)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Health of device. Ranges between 0 and 8 where
|
|
0 worst case and 8 is best case. Incremented
|
|
every time device responds to a search, decremented
|
|
if it does not respond."
|
|
::= { owDeviceEntry 7 }
|
|
|
|
owDS2406Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OwDS2406Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for DS2406 (dual addressable switch plus
|
|
1K bit memory)."
|
|
::= { owDevices 4 }
|
|
|
|
owDS2406Entry OBJECT-TYPE
|
|
SYNTAX OwDS2406Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owDS2406Table 1 }
|
|
|
|
OwDS2406Entry ::= SEQUENCE {
|
|
owDS2406PIOALevel
|
|
INTEGER,
|
|
owDS2406PIOBLevel
|
|
INTEGER,
|
|
owDS2406PIOAFlipFlop
|
|
INTEGER,
|
|
owDS2406PIOBFlipFlop
|
|
INTEGER,
|
|
owDS2406PIOAActivityLatch
|
|
INTEGER,
|
|
owDS2406PIOBActivityLatch
|
|
INTEGER,
|
|
owDS2406NumChnls
|
|
INTEGER,
|
|
owDS2406PwrSupply
|
|
INTEGER,
|
|
owDS2406ActivityLatchReset
|
|
INTEGER
|
|
}
|
|
|
|
owDS2406PIOALevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "PIO-A logic level on pin. If PIO-A flip flop is
|
|
low, this input will always read low."
|
|
::= { owDS2406Entry 1 }
|
|
|
|
owDS2406PIOBLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "PIO-B logic level on pin. If PIO-B flip flop is
|
|
low, this input will always read low."
|
|
::= { owDS2406Entry 2 }
|
|
|
|
owDS2406PIOAFlipFlop OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "DS2406 PIO-A Flip Flop. Sets output state of the
|
|
FF. The output is open collector, so the FF must
|
|
be high (1) to be able to read a pin state of
|
|
low (0)."
|
|
::= { owDS2406Entry 3 }
|
|
|
|
owDS2406PIOBFlipFlop OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "DS2406 PIO-B Flip Flop. Sets output state of the
|
|
FF. The output is open collector, so the FF must
|
|
be high (1) to be able to read a pin state of
|
|
low (0)."
|
|
::= { owDS2406Entry 4 }
|
|
|
|
owDS2406PIOAActivityLatch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noActivity( 0 ),
|
|
yesActivity( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "High (1) if the pin state had activity. Reset
|
|
by writing to activity latch reset."
|
|
::= { owDS2406Entry 5 }
|
|
|
|
owDS2406PIOBActivityLatch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noActivity( 0 ),
|
|
yesActivity( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "High (1) if the pin state had activity. Reset
|
|
by writing to activity latch reset."
|
|
::= { owDS2406Entry 6 }
|
|
|
|
owDS2406NumChnls OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pioAonly( 0 ),
|
|
pioAandB( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number of PIO channels the device supports. PIO-A
|
|
only is 0, PIO-A and PIO-B is 1."
|
|
::= { owDS2406Entry 7 }
|
|
|
|
owDS2406PwrSupply OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pwrParasite( 0 ),
|
|
pwrExternal( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Source of power for device. 0 is parasite powered,
|
|
1 is externally powered."
|
|
::= { owDS2406Entry 8 }
|
|
|
|
owDS2406ActivityLatchReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noReset( 0 ),
|
|
yesReset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity latch reset is used to reset both PIO-A
|
|
and PIO-B activity latch. Send 1 to reset the
|
|
latch. Always reads 0."
|
|
::= { owDS2406Entry 9 }
|
|
|
|
owDS18B20Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OwDS18B20Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for DS18B20 (programmable resolution 1-wire
|
|
digital thermometer)."
|
|
::= { owDevices 5 }
|
|
|
|
owDS18B20Entry OBJECT-TYPE
|
|
SYNTAX OwDS18B20Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owDS18B20Table 1 }
|
|
|
|
OwDS18B20Entry ::= SEQUENCE {
|
|
owDS18B20Temperature
|
|
DisplayString,
|
|
owDS18B20UserByte1
|
|
INTEGER,
|
|
owDS18B20UserByte2
|
|
INTEGER,
|
|
owDS18B20Resolution
|
|
INTEGER,
|
|
owDS18B20PwrSupply
|
|
INTEGER
|
|
}
|
|
|
|
owDS18B20Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Current temperature from device, desplayed as
|
|
a string with decimal point. Required since MIB's
|
|
cannot contain floating point numbers."
|
|
::= { owDS18B20Entry 1 }
|
|
|
|
owDS18B20UserByte1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "User byte 1 as read from EEPROM."
|
|
::= { owDS18B20Entry 2 }
|
|
|
|
owDS18B20UserByte2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "User byte 2 as read from EEPROM."
|
|
::= { owDS18B20Entry 3 }
|
|
|
|
owDS18B20Resolution OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nineBits( 9 ),
|
|
tenBits( 10 ),
|
|
elevenBits( 11 ),
|
|
twelveBits( 12 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Resolution of temperature reading, can be 9, 10,
|
|
11 or 12 bits. Default is 12 bits. 0 is 9 bits,
|
|
1 is 10 bits, 2 is 11 bits and 3 is 12 bits."
|
|
::= { owDS18B20Entry 4 }
|
|
|
|
owDS18B20PwrSupply OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
parasitePower( 0 ),
|
|
externalPower( 255 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Power source. Parasite or external. Zero is parasite."
|
|
::= { owDS18B20Entry 5 }
|
|
|
|
owDS18S20Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OwDS18S20Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for DS18S20 device data."
|
|
::= { owDevices 6 }
|
|
|
|
owDS18S20Entry OBJECT-TYPE
|
|
SYNTAX OwDS18S20Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owDS18S20Table 1 }
|
|
|
|
OwDS18S20Entry ::= SEQUENCE {
|
|
owDS18S20Temperature
|
|
DisplayString,
|
|
owDS18S20UserByte1
|
|
INTEGER,
|
|
owDS18S20UserByte2
|
|
INTEGER
|
|
}
|
|
|
|
owDS18S20Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Latest temperature reading, in degrees centigrade."
|
|
::= { owDS18S20Entry 1 }
|
|
|
|
owDS18S20UserByte1 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "User byte from device EEPROM."
|
|
::= { owDS18S20Entry 2 }
|
|
|
|
owDS18S20UserByte2 OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "User byte from device EEPROM."
|
|
::= { owDS18S20Entry 3 }
|
|
|
|
|
|
-- DS2423 TABLE
|
|
|
|
owDS2423Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OwDS2423Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for DS2423 device data."
|
|
::= { owDevices 7 }
|
|
|
|
owDS2423Entry OBJECT-TYPE
|
|
SYNTAX OwDS2423Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owDS2423Table 1 }
|
|
|
|
OwDS2423Entry ::= SEQUENCE {
|
|
owDS2423CounterA
|
|
COUNTER32,
|
|
owDS2423CounterB
|
|
COUNTER32
|
|
}
|
|
|
|
owDS2423CounterA OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter A value."
|
|
::= { owDS2423Entry 1 }
|
|
|
|
owDS2423CounterB OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter B value."
|
|
::= { owDS2423Entry 2 }
|
|
|
|
|
|
-- DS2438 TABLE
|
|
|
|
owDS2438Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OwDS2438Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for DS2438 device data."
|
|
::= { owDevices 8 }
|
|
|
|
owDS2438Entry OBJECT-TYPE
|
|
SYNTAX OwDS2438Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owDS2438Table 1 }
|
|
|
|
OwDS2438Entry ::= SEQUENCE {
|
|
owDS2438Temperature
|
|
DisplayString,
|
|
owDS2438SupplyVoltage
|
|
DisplayString,
|
|
owDS2438Current
|
|
DisplayString,
|
|
owDS2438PinVoltage
|
|
DisplayString,
|
|
owDS2438Humidity
|
|
DisplayString
|
|
}
|
|
|
|
owDS2438Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { owDS2438Entry 1 }
|
|
|
|
owDS2438SupplyVoltage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Voltage of the power supply."
|
|
::= { owDS2438Entry 2 }
|
|
|
|
owDS2438PinVoltage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Voltage at Pin Vad (pin 4)."
|
|
::= { owDS2438Entry 3 }
|
|
|
|
owDS2438Current OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Voltage between the current pins."
|
|
::= { owDS2438Entry 4 }
|
|
|
|
owDS2438Humidity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Calculated humidity."
|
|
::= { owDS2438Entry 5 }
|
|
|
|
-- DS2408 TABLE
|
|
|
|
owDS2408Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OwDS2408Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for DS2408 (8-channel addressable switch)."
|
|
::= { owDevices 9 }
|
|
|
|
owDS2408Entry OBJECT-TYPE
|
|
SYNTAX owDS2408Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owDS2408Table 1 }
|
|
|
|
owDS2408Entry ::= SEQUENCE {
|
|
owDS2408PIOLogicState
|
|
INTEGER,
|
|
owDS2408PIOOutputLatchState
|
|
INTEGER,
|
|
owDS2408PIOActivityLatchState
|
|
INTEGER,
|
|
owDS2408RSTZConfiguration
|
|
INTEGER,
|
|
owDS2408PowerOnResetLatch
|
|
INTEGER,
|
|
owDS2408VCCPowerStatus
|
|
INTEGER
|
|
}
|
|
|
|
owDS2408PIOLogicState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Logic level on the 8 IO pins."
|
|
::= { owDS2408Entry 1 }
|
|
|
|
owDS2408PIOOutputLatchState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output latch states. Sets output state of the
|
|
FFs. The output is open collector, so the FF must
|
|
be high (1) to be able to read a pin state of
|
|
low (0)."
|
|
::= { owDS2408Entry 2 }
|
|
|
|
owDS2408PIOActivityLatchState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 255 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "High (1) if the pin state had activity. Reset
|
|
by writing to activity latch reset."
|
|
::= { owDS2408Entry 3 }
|
|
|
|
owDS2408RSTZConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Configures the RSTZ pin as a /RSTZ input (set to 0)
|
|
or a /STRB output (set to 1)."
|
|
::= { owDS2408Entry 4 }
|
|
|
|
owDS2408PowerOnResetLatch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Set high (1) with a power on reset. Reset
|
|
by writing to a 0."
|
|
::= { owDS2408Entry 5 }
|
|
|
|
owDS2408VCCPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "High (1) if the VCC pin is connected to power,
|
|
low (0) otherwise."
|
|
::= { owDS2408Entry 6 }
|
|
|
|
|
|
-- DS2450 TABLE
|
|
|
|
owDS2450Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OwDS2450Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for DS2450 (8-channel addressable switch)."
|
|
::= { owDevices 10 }
|
|
|
|
owDS2450Entry OBJECT-TYPE
|
|
SYNTAX owDS2450Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owDS2450Table 1 }
|
|
|
|
owDS2450Entry ::= SEQUENCE {
|
|
owDS2450ChannelAConversionValue
|
|
DisplayString,
|
|
owDS2450ChannelAConversionResolution
|
|
INTEGER,
|
|
owDS2450ChannelAConversionRange
|
|
INTEGER,
|
|
owDS2450ChannelAOutputEnable
|
|
INTEGER,
|
|
owDS2450ChannelAOutputControl
|
|
INTEGER,
|
|
owDS2450ChannelBConversionValue
|
|
DisplayString,
|
|
owDS2450ChannelBConversionResolution
|
|
INTEGER,
|
|
owDS2450ChannelBConversionRange
|
|
INTEGER,
|
|
owDS2450ChannelBOutputEnable
|
|
INTEGER,
|
|
owDS2450ChannelBOutputControl
|
|
INTEGER,
|
|
owDS2450ChannelCConversionValue
|
|
DisplayString,
|
|
owDS2450ChannelCConversionResolution
|
|
INTEGER,
|
|
owDS2450ChannelCConversionRange
|
|
INTEGER,
|
|
owDS2450ChannelCOutputEnable
|
|
INTEGER,
|
|
owDS2450ChannelCOutputControl
|
|
INTEGER,
|
|
owDS2450ChannelDConversionValue
|
|
DisplayString,
|
|
owDS2450ChannelDConversionResolution
|
|
INTEGER,
|
|
owDS2450ChannelDConversionRange
|
|
INTEGER,
|
|
owDS2450ChannelDOutputEnable
|
|
INTEGER,
|
|
owDS2450ChannelDOutputControl
|
|
INTEGER,
|
|
owDS2450PowerOnReset
|
|
INTEGER,
|
|
owDS2450VCCControl
|
|
INTEGER
|
|
}
|
|
|
|
owDS2450ChannelAConversionValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Conversion value of the channel, in volts."
|
|
::= { owDS2450Entry 1 }
|
|
|
|
owDS2450ChannelAConversionResolution OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Conversion resolution of the channel. Can be set
|
|
between 1 and 16."
|
|
::= { owDS2450Entry 2 }
|
|
|
|
owDS2450ChannelAConversionRange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "If high (1), the maximum voltage that can be
|
|
measured is 5.10, low (0) sets the maximum voltage
|
|
to 2.55."
|
|
::= { owDS2450Entry 3 }
|
|
|
|
owDS2450ChannelAOutputEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "A setting of 1 enables the output transistor, use
|
|
ChannelXOutputControl to turn the transistor on / off."
|
|
::= { owDS2450Entry 4 }
|
|
|
|
owDS2450ChannelAOutputControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Set to low (0) to turn on the output transistor. Has
|
|
no effect if ChannelXOutputEnable is low (0)."
|
|
::= { owDS2450Entry 5 }
|
|
|
|
owDS2450ChannelBConversionValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Conversion value of the channel, in volts."
|
|
::= { owDS2450Entry 6 }
|
|
|
|
owDS2450ChannelBConversionResolution OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Conversion resolution of the channel. Can be set
|
|
between 1 and 16."
|
|
::= { owDS2450Entry 7 }
|
|
|
|
owDS2450ChannelBConversionRange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "If high (1), the maximum voltage that can be
|
|
measured is 5.10, low (0) sets the maximum voltage
|
|
to 2.55."
|
|
::= { owDS2450Entry 8 }
|
|
|
|
owDS2450ChannelBOutputEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "A setting of 1 enables the output transistor, use
|
|
ChannelXOutputControl to turn the transistor on / off."
|
|
::= { owDS2450Entry 9 }
|
|
|
|
owDS2450ChannelBOutputControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Set to low (0) to turn on the output transistor. Has
|
|
no effect if ChannelXOutputEnable is low (0)."
|
|
::= { owDS2450Entry 10 }
|
|
|
|
owDS2450ChannelCConversionValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Conversion value of the channel, in volts."
|
|
::= { owDS2450Entry 11 }
|
|
|
|
owDS2450ChannelCConversionResolution OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Conversion resolution of the channel. Can be set
|
|
between 1 and 16."
|
|
::= { owDS2450Entry 12 }
|
|
|
|
owDS2450ChannelCConversionRange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "If high (1), the maximum voltage that can be
|
|
measured is 5.10, low (0) sets the maximum voltage
|
|
to 2.55."
|
|
::= { owDS2450Entry 13 }
|
|
|
|
owDS2450ChannelCOutputEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "A setting of 1 enables the output transistor, use
|
|
ChannelXOutputControl to turn the transistor on / off."
|
|
::= { owDS2450Entry 14 }
|
|
|
|
owDS2450ChannelCOutputControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Set to low (0) to turn on the output transistor. Has
|
|
no effect if ChannelXOutputEnable is low (0)."
|
|
::= { owDS2450Entry 15 }
|
|
|
|
owDS2450ChannelDConversionValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Conversion value of the channel, in volts."
|
|
::= { owDS2450Entry 16 }
|
|
|
|
owDS2450ChannelDConversionResolution OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Conversion resolution of the channel. Can be set
|
|
between 1 and 16."
|
|
::= { owDS2450Entry 17 }
|
|
|
|
owDS2450ChannelDConversionRange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "If high (1), the maximum voltage that can be
|
|
measured is 5.10, low (0) sets the maximum voltage
|
|
to 2.55."
|
|
::= { owDS2450Entry 18 }
|
|
|
|
owDS2450ChannelDOutputEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "A setting of 1 enables the output transistor, use
|
|
ChannelXOutputControl to turn the transistor on / off."
|
|
::= { owDS2450Entry 19 }
|
|
|
|
owDS2450ChannelDOutputControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Set to low (0) to turn on the output transistor. Has
|
|
no effect if ChannelXOutputEnable is low (0)."
|
|
::= { owDS2450Entry 20 }
|
|
|
|
owDS2450PowerOnReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Set high (1) with a power on reset. Reset
|
|
by writing any value."
|
|
::= { owDS2450Entry 21 }
|
|
|
|
owDS2450VCCControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Set high (1) if the VCC pin is connected to power,
|
|
set low (0) otherwise."
|
|
::= { owDS2450Entry 22 }
|
|
|
|
-- EDS0064 TABLE
|
|
|
|
owEDS0064Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0064Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0064 device data (temperature)"
|
|
::= { owDevices 11 }
|
|
|
|
owEDS0064Entry OBJECT-TYPE
|
|
SYNTAX owEDS0064Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0064Table 1 }
|
|
|
|
owEDS0064Entry ::= SEQUENCE {
|
|
owEDS0064Temperature
|
|
DisplayString,
|
|
owEDS0064Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0064Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { owEDS0064Entry 1 }
|
|
|
|
owEDS0064Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0064Entry 2 }
|
|
|
|
-- EDS0065 TABLE
|
|
|
|
owEDS0065Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0065Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0065 device data (temperature and humiditiy)."
|
|
::= { owDevices 12 }
|
|
|
|
owEDS0065Entry OBJECT-TYPE
|
|
SYNTAX owEDS0065Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0065Table 1 }
|
|
|
|
owEDS0065Entry ::= SEQUENCE {
|
|
owEDS0065Temperature
|
|
DisplayString,
|
|
owEDS0065Humidity
|
|
DisplayString,
|
|
owEDS0065DewPoint
|
|
DisplayString,
|
|
owEDS0065Humidex
|
|
DisplayString,
|
|
owEDS0065HeatIndex
|
|
DisplayString,
|
|
owEDS0065Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0065Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { owEDS0065Entry 1 }
|
|
|
|
owEDS0065Humidity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Humidity."
|
|
::= { owEDS0065Entry 2 }
|
|
|
|
owEDS0065DewPoint OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "DewPoint."
|
|
::= { owEDS0065Entry 3 }
|
|
|
|
owEDS0065Humidex OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Humidex."
|
|
::= { owEDS0065Entry 4 }
|
|
|
|
owEDS0065HeatIndex OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Heat Index."
|
|
::= { owEDS0065Entry 5 }
|
|
|
|
owEDS0065Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0065Entry 6 }
|
|
|
|
-- EDS0066 TABLE
|
|
|
|
owEDS0066Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0066Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0001 device data (temperature and barometric pressure)."
|
|
::= { owDevices 13 }
|
|
|
|
owEDS0066Entry OBJECT-TYPE
|
|
SYNTAX owEDS0066Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0066Table 1 }
|
|
|
|
owEDS0066Entry ::= SEQUENCE {
|
|
owEDS0066Temperature
|
|
DisplayString,
|
|
owEDS0066BarometricPressureMb
|
|
DisplayString,
|
|
owEDS0066BarometricPressureHg
|
|
DisplayString,
|
|
owEDS0066Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0066Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { owEDS0066Entry 1 }
|
|
|
|
owEDS0066BarometricPressureMb OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Barometric Pressure in Millibars."
|
|
::= { owEDS0066Entry 2 }
|
|
|
|
owEDS0066BarometricPressureHg OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Barometric Pressure in Inches of Mercury."
|
|
::= { owEDS0066Entry 3 }
|
|
|
|
owEDS0066Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0066Entry 4 }
|
|
|
|
-- EDS0067 TABLE
|
|
|
|
owEDS0067Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0067Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0067 device data (temperature and light)."
|
|
::= { owDevices 14 }
|
|
|
|
owEDS0067Entry OBJECT-TYPE
|
|
SYNTAX owEDS0067Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0067Table 1 }
|
|
|
|
owEDS0067Entry ::= SEQUENCE {
|
|
owEDS0067Temperature
|
|
DisplayString,
|
|
owEDS0067Light,
|
|
DisplayString,
|
|
owEDS0067Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0067Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { owEDS0067Entry 1 }
|
|
|
|
owEDS0067Light OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Light."
|
|
::= { owEDS0067Entry 2 }
|
|
|
|
owEDS0067Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0067Entry 3 }
|
|
|
|
-- EDS0068 TABLE
|
|
|
|
owEDS0068Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0068Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0068 device data (temperature, humidity, barometric pressure and light)."
|
|
::= { owDevices 15 }
|
|
|
|
owEDS0068Entry OBJECT-TYPE
|
|
SYNTAX owEDS0068Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0068Table 1 }
|
|
|
|
owEDS0068Entry ::= SEQUENCE {
|
|
owEDS0068Temperature
|
|
DisplayString,
|
|
owEDS0068Humidity
|
|
DisplayString,
|
|
owEDS0068DewPoint
|
|
DisplayString,
|
|
owEDS0068Humidex
|
|
DisplayString,
|
|
owEDS0068HeatIndex
|
|
DisplayString,
|
|
owEDS0068BarometricPressureMb
|
|
DisplayString,
|
|
owEDS0068BarometricPressureHg
|
|
DisplayString,
|
|
owEDS0068Light,
|
|
DisplayString,
|
|
owEDS0068Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0068Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { owEDS0068Entry 1 }
|
|
|
|
owEDS0068Humidity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Humidity."
|
|
::= { owEDS0068Entry 2 }
|
|
|
|
owEDS0068DewPoint OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "DewPoint."
|
|
::= { owEDS0068Entry 3 }
|
|
|
|
owEDS0068Humidex OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Humidex."
|
|
::= { owEDS0068Entry 4 }
|
|
|
|
owEDS0068HeatIndex OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Heat Index."
|
|
::= { owEDS0068Entry 5 }
|
|
|
|
owEDS0068BarometricPressureMb OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Barometric Pressure in Millibars."
|
|
::= { owEDS0068Entry 6 }
|
|
|
|
owEDS0068BarometricPressureHg OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Barometric Pressure in Inches of Mercury."
|
|
::= { owEDS0068Entry 7 }
|
|
|
|
owEDS0068Light OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Light."
|
|
::= { owEDS0068Entry 8 }
|
|
|
|
owEDS0068Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0068Entry 9 }
|
|
|
|
-- EDS0069 TABLE - motion
|
|
|
|
owEDS0069Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0069Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0069 device data (temperature and motion)."
|
|
::= { owDevices 16 }
|
|
|
|
owEDS0069Entry OBJECT-TYPE
|
|
SYNTAX owEDS0069Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0069Table 1 }
|
|
|
|
owEDS0069Entry ::= SEQUENCE {
|
|
owEDS0069Temperature
|
|
DisplayString,
|
|
owEDS0069Motion
|
|
DisplayString,
|
|
owEDS0069Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0069Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { owEDS0069Entry 1 }
|
|
|
|
owEDS0069Motion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Motion counter."
|
|
::= { owEDS0069Entry 2 }
|
|
|
|
owEDS0069Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0069Entry 3 }
|
|
|
|
-- EDS0070 TABLE - vibration
|
|
|
|
owEDS0070Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0070Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0070 device data (vibration)."
|
|
::= { owDevices 17 }
|
|
|
|
owEDS0070Entry OBJECT-TYPE
|
|
SYNTAX owEDS0070Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0070Table 1 }
|
|
|
|
owEDS0070Entry ::= SEQUENCE {
|
|
owEDS0070VibrationInstant
|
|
INTEGER,
|
|
owEDS0070VibrationPeak
|
|
INTEGER,
|
|
owEDS0070VibrationMax
|
|
INTEGER,
|
|
owEDS0070VibrationMin
|
|
INTEGER,
|
|
owEDS0070Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0070VibrationInstant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 65535 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Vibration, instant value."
|
|
::= { owEDS0070Entry 1 }
|
|
|
|
owEDS0070VibrationPeak OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 65535 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Vibration, instant value."
|
|
::= { owEDS0070Entry 2 }
|
|
|
|
owEDS0070VibrationMax OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 65535 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Vibration, instant value."
|
|
::= { owEDS0070Entry 3 }
|
|
|
|
owEDS0070VibrationMin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 65535 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Vibration, instant value."
|
|
::= { owEDS0070Entry 4 }
|
|
|
|
owEDS0070Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0070Entry 5 }
|
|
|
|
-- EDS0071 TABLE - RTD 4-wire
|
|
|
|
owEDS0071Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0071Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0071 device data (RTD 4-wire)."
|
|
::= { owDevices 18 }
|
|
|
|
owEDS0071Entry OBJECT-TYPE
|
|
SYNTAX owEDS0071Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0071Table 1 }
|
|
|
|
owEDS0071Entry ::= SEQUENCE {
|
|
owEDS0071Temperature
|
|
DisplayString,
|
|
owEDS0071Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0071Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { owEDS0071Entry 1 }
|
|
|
|
owEDS0071Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0071Entry 2 }
|
|
|
|
-- EDS0080 TABLE - octal 4-20ma
|
|
|
|
owEDS0080Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0080Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0080 device data (octal 4-20ma)."
|
|
::= { owDevices 19 }
|
|
|
|
owEDS0080Entry OBJECT-TYPE
|
|
SYNTAX owEDS0080Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0080Table 1 }
|
|
|
|
owEDS0080Entry ::= SEQUENCE {
|
|
owEDS0080Input1
|
|
DisplayString,
|
|
owEDS0080Input2
|
|
DisplayString,
|
|
owEDS0080Input3
|
|
DisplayString,
|
|
owEDS0080Input4
|
|
DisplayString,
|
|
owEDS0080Input5
|
|
DisplayString,
|
|
owEDS0080Input6
|
|
DisplayString,
|
|
owEDS0080Input7
|
|
DisplayString,
|
|
owEDS0080Input8
|
|
DisplayString,
|
|
owEDS0080Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0080Input1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1."
|
|
::= { owEDS0080Entry 1 }
|
|
|
|
owEDS0080Input2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 2."
|
|
::= { owEDS0080Entry 2 }
|
|
|
|
owEDS0080Input3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 3."
|
|
::= { owEDS0080Entry 3 }
|
|
|
|
owEDS0080Input4 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 4."
|
|
::= { owEDS0080Entry 4 }
|
|
|
|
owEDS0080Input5 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 5."
|
|
::= { owEDS0080Entry 5 }
|
|
|
|
owEDS0080Input6 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 6."
|
|
::= { owEDS0080Entry 6 }
|
|
|
|
owEDS0080Input7 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 7."
|
|
::= { owEDS0080Entry 7 }
|
|
|
|
owEDS0080Input8 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 8."
|
|
::= { owEDS0080Entry 8 }
|
|
|
|
owEDS0080Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0080Entry 9 }
|
|
|
|
-- EDS0082 TABLE - octal 0-10v
|
|
|
|
owEDS0082Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0082Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0082 device data (octal 0-10v)."
|
|
::= { owDevices 20 }
|
|
|
|
owEDS0082Entry OBJECT-TYPE
|
|
SYNTAX owEDS0082Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0082Table 1 }
|
|
|
|
owEDS0082Entry ::= SEQUENCE {
|
|
owEDS0082Input1
|
|
DisplayString,
|
|
owEDS0082Input2
|
|
DisplayString,
|
|
owEDS0082Input3
|
|
DisplayString,
|
|
owEDS0082Input4
|
|
DisplayString,
|
|
owEDS0082Input5
|
|
DisplayString,
|
|
owEDS0082Input6
|
|
DisplayString,
|
|
owEDS0082Input7
|
|
DisplayString,
|
|
owEDS0082Input8
|
|
DisplayString,
|
|
owEDS0082Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0082Input1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1."
|
|
::= { owEDS0082Entry 1 }
|
|
|
|
owEDS0082Input2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 2."
|
|
::= { owEDS0082Entry 2 }
|
|
|
|
owEDS0082Input3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 3."
|
|
::= { owEDS0082Entry 3 }
|
|
|
|
owEDS0082Input4 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 4."
|
|
::= { owEDS0082Entry 4 }
|
|
|
|
owEDS0082Input5 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 5."
|
|
::= { owEDS0082Entry 5 }
|
|
|
|
owEDS0082Input6 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 6."
|
|
::= { owEDS0082Entry 6 }
|
|
|
|
owEDS0082Input7 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 7."
|
|
::= { owEDS0082Entry 7 }
|
|
|
|
owEDS0082Input8 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 8."
|
|
::= { owEDS0082Entry 8 }
|
|
|
|
owEDS0082Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0082Entry 9 }
|
|
|
|
-- EDS0083 TABLE - quad 4-20ma
|
|
|
|
owEDS0083Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0083Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0083 device data (quad 4-20ma)."
|
|
::= { owDevices 21 }
|
|
|
|
owEDS0083Entry OBJECT-TYPE
|
|
SYNTAX owEDS0083Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0083Table 1 }
|
|
|
|
owEDS0083Entry ::= SEQUENCE {
|
|
owEDS0083Input1
|
|
DisplayString,
|
|
owEDS0083Input2
|
|
DisplayString,
|
|
owEDS0083Input3
|
|
DisplayString,
|
|
owEDS0083Input4
|
|
DisplayString,
|
|
owEDS0083Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0083Input1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1."
|
|
::= { owEDS0083Entry 1 }
|
|
|
|
owEDS0083Input2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 2."
|
|
::= { owEDS0083Entry 2 }
|
|
|
|
owEDS0083Input3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 3."
|
|
::= { owEDS0083Entry 3 }
|
|
|
|
owEDS0083Input4 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 4."
|
|
::= { owEDS0083Entry 4 }
|
|
|
|
owEDS0083Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0083Entry 5 }
|
|
|
|
-- EDS0085 TABLE - quad 0-10v
|
|
|
|
owEDS0085Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0085Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0085 device data (quad 0-10v)."
|
|
::= { owDevices 22 }
|
|
|
|
owEDS0085Entry OBJECT-TYPE
|
|
SYNTAX owEDS0085Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0085Table 1 }
|
|
|
|
owEDS0085Entry ::= SEQUENCE {
|
|
owEDS0085Input1
|
|
DisplayString,
|
|
owEDS0085Input2
|
|
DisplayString,
|
|
owEDS0085Input3
|
|
DisplayString,
|
|
owEDS0085Input4
|
|
DisplayString,
|
|
owEDS0085Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0085Input1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1."
|
|
::= { owEDS0085Entry 1 }
|
|
|
|
owEDS0085Input2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 2."
|
|
::= { owEDS0085Entry 2 }
|
|
|
|
owEDS0085Input3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 3."
|
|
::= { owEDS0085Entry 3 }
|
|
|
|
owEDS0085Input4 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 4."
|
|
::= { owEDS0085Entry 4 }
|
|
|
|
owEDS0085Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0085Entry 5 }
|
|
|
|
-- EDS0090 TABLE - octal discrete IO
|
|
|
|
owEDS0090Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0090Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0090 device data (octal discrete IO)."
|
|
::= { owDevices 23 }
|
|
|
|
owEDS0090Entry OBJECT-TYPE
|
|
SYNTAX owEDS0090Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0090Table 1 }
|
|
|
|
owEDS0090Entry ::= SEQUENCE {
|
|
owEDS0090Input1
|
|
INTEGER,
|
|
owEDS0090Input2
|
|
INTEGER,
|
|
owEDS0090Input3
|
|
INTEGER,
|
|
owEDS0090Input4
|
|
INTEGER,
|
|
owEDS0090Input5
|
|
INTEGER,
|
|
owEDS0090Input6
|
|
INTEGER,
|
|
owEDS0090Input7
|
|
INTEGER,
|
|
owEDS0090Input8
|
|
INTEGER,
|
|
owEDS0090ActivityLatch1
|
|
INTEGER,
|
|
owEDS0090ActivityLatch2
|
|
INTEGER,
|
|
owEDS0090ActivityLatch3
|
|
INTEGER,
|
|
owEDS0090ActivityLatch4
|
|
INTEGER,
|
|
owEDS0090ActivityLatch5
|
|
INTEGER,
|
|
owEDS0090ActivityLatch6
|
|
INTEGER,
|
|
owEDS0090ActivityLatch7
|
|
INTEGER,
|
|
owEDS0090ActivityLatch8
|
|
INTEGER,
|
|
owEDS0090PulseCounter1
|
|
COUNTER32,
|
|
owEDS0090PulseCounter2
|
|
COUNTER32,
|
|
owEDS0090PulseCounter3
|
|
COUNTER32,
|
|
owEDS0090PulseCounter4
|
|
COUNTER32,
|
|
owEDS0090PulseCounter5
|
|
COUNTER32,
|
|
owEDS0090PulseCounter6
|
|
COUNTER32,
|
|
owEDS0090PulseCounter7
|
|
COUNTER32,
|
|
owEDS0090PulseCounter8
|
|
COUNTER32,
|
|
owEDS0090Output1
|
|
INTEGER,
|
|
owEDS0090Output2
|
|
INTEGER,
|
|
owEDS0090Output3
|
|
INTEGER,
|
|
owEDS0090Output4
|
|
INTEGER,
|
|
owEDS0090Output5
|
|
INTEGER,
|
|
owEDS0090Output6
|
|
INTEGER,
|
|
owEDS0090Output7
|
|
INTEGER,
|
|
owEDS0090Output8
|
|
INTEGER,
|
|
owEDS0090PullDown1
|
|
INTEGER,
|
|
owEDS0090PullDown2
|
|
INTEGER,
|
|
owEDS0090PullDown3
|
|
INTEGER,
|
|
owEDS0090PullDown4
|
|
INTEGER,
|
|
owEDS0090PullDown5
|
|
INTEGER,
|
|
owEDS0090PullDown6
|
|
INTEGER,
|
|
owEDS0090PullDown7
|
|
INTEGER,
|
|
owEDS0090PullDown8
|
|
INTEGER,
|
|
owEDS0090ActivityLatchReset1
|
|
INTEGER,
|
|
owEDS0090ActivityLatchReset2
|
|
INTEGER,
|
|
owEDS0090ActivityLatchReset3
|
|
INTEGER,
|
|
owEDS0090ActivityLatchReset4
|
|
INTEGER,
|
|
owEDS0090ActivityLatchReset5
|
|
INTEGER,
|
|
owEDS0090ActivityLatchReset6
|
|
INTEGER,
|
|
owEDS0090ActivityLatchReset7
|
|
INTEGER,
|
|
owEDS0090ActivityLatchReset8
|
|
INTEGER,
|
|
owEDS0090PulseCounterReset1
|
|
INTEGER,
|
|
owEDS0090PulseCounterReset2
|
|
INTEGER,
|
|
owEDS0090PulseCounterReset3
|
|
INTEGER,
|
|
owEDS0090PulseCounterReset4
|
|
INTEGER,
|
|
owEDS0090PulseCounterReset5
|
|
INTEGER,
|
|
owEDS0090PulseCounterReset6
|
|
INTEGER,
|
|
owEDS0090PulseCounterReset7
|
|
INTEGER,
|
|
owEDS0090PulseCounterReset8
|
|
INTEGER,
|
|
|
|
owEDS0090Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0090Input1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1."
|
|
::= { owEDS0090Entry 1 }
|
|
|
|
owEDS0090Input2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 2."
|
|
::= { owEDS0090Entry 2 }
|
|
|
|
owEDS0090Input3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 3."
|
|
::= { owEDS0090Entry 3 }
|
|
|
|
owEDS0090Input4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 4."
|
|
::= { owEDS0090Entry 4 }
|
|
|
|
owEDS0090Input5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 5."
|
|
::= { owEDS0090Entry 5 }
|
|
|
|
owEDS0090Input6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 6."
|
|
::= { owEDS0090Entry 6 }
|
|
|
|
owEDS0090Input7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 7."
|
|
::= { owEDS0090Entry 7 }
|
|
|
|
owEDS0090Input8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 8."
|
|
::= { owEDS0090Entry 8 }
|
|
|
|
owEDS0090ActivityLatch1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 1."
|
|
::= { owEDS0090Entry 9 }
|
|
|
|
owEDS0090ActivityLatch2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 2."
|
|
::= { owEDS0090Entry 10 }
|
|
|
|
owEDS0090ActivityLatch3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 3."
|
|
::= { owEDS0090Entry 11 }
|
|
|
|
owEDS0090ActivityLatch4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 4."
|
|
::= { owEDS0090Entry 12 }
|
|
|
|
owEDS0090ActivityLatch5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 5."
|
|
::= { owEDS0090Entry 13 }
|
|
|
|
owEDS0090ActivityLatch6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 6."
|
|
::= { owEDS0090Entry 14 }
|
|
|
|
owEDS0090ActivityLatch7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 7."
|
|
::= { owEDS0090Entry 15 }
|
|
|
|
owEDS0090ActivityLatch8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 8."
|
|
::= { owEDS0090Entry 16 }
|
|
|
|
owEDS0090PulseCounter1 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 1."
|
|
::= { owEDS0090Entry 17 }
|
|
|
|
owEDS0090PulseCounter2 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 2."
|
|
::= { owEDS0090Entry 18 }
|
|
|
|
owEDS0090PulseCounter3 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 3."
|
|
::= { owEDS0090Entry 19 }
|
|
|
|
owEDS0090PulseCounter4 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 4."
|
|
::= { owEDS0090Entry 20 }
|
|
|
|
owEDS0090PulseCounter5 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 5."
|
|
::= { owEDS0090Entry 21 }
|
|
|
|
owEDS0090PulseCounter6 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 6."
|
|
::= { owEDS0090Entry 22 }
|
|
|
|
owEDS0090PulseCounter7 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 7."
|
|
::= { owEDS0090Entry 23 }
|
|
|
|
owEDS0090PulseCounter8 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 8."
|
|
::= { owEDS0090Entry 24 }
|
|
|
|
owEDS0090Output1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 1."
|
|
::= { owEDS0090Entry 25 }
|
|
|
|
owEDS0090Output2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 2."
|
|
::= { owEDS0090Entry 26 }
|
|
|
|
owEDS0090Output3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 3."
|
|
::= { owEDS0090Entry 27 }
|
|
|
|
owEDS0090Output4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 4."
|
|
::= { owEDS0090Entry 28 }
|
|
|
|
owEDS0090Output5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 5."
|
|
::= { owEDS0090Entry 29 }
|
|
|
|
owEDS0090Output6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 6."
|
|
::= { owEDS0090Entry 30 }
|
|
|
|
owEDS0090Output7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 7."
|
|
::= { owEDS0090Entry 31 }
|
|
|
|
owEDS0090Output8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 8."
|
|
::= { owEDS0090Entry 32 }
|
|
|
|
owEDS0090PullDown1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "PullDown 1."
|
|
::= { owEDS0090Entry 33 }
|
|
|
|
owEDS0090PullDown2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "PullDown 1."
|
|
::= { owEDS0090Entry 34 }
|
|
|
|
owEDS0090PullDown3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "PullDown 1."
|
|
::= { owEDS0090Entry 35 }
|
|
|
|
owEDS0090PullDown4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "PullDown 1."
|
|
::= { owEDS0090Entry 36 }
|
|
|
|
owEDS0090PullDown5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "PullDown 1."
|
|
::= { owEDS0090Entry 37 }
|
|
|
|
owEDS0090PullDown6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "PullDown 1."
|
|
::= { owEDS0090Entry 38 }
|
|
|
|
owEDS0090PullDown7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "PullDown 1."
|
|
::= { owEDS0090Entry 39 }
|
|
|
|
owEDS0090PullDown8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "PullDown 1."
|
|
::= { owEDS0090Entry 40 }
|
|
|
|
owEDS0090ActivityLatchReset1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 1."
|
|
::= { owEDS0090Entry 41 }
|
|
|
|
owEDS0090ActivityLatchReset2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 2."
|
|
::= { owEDS0090Entry 42 }
|
|
|
|
owEDS0090ActivityLatchReset3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 3."
|
|
::= { owEDS0090Entry 43 }
|
|
|
|
owEDS0090ActivityLatchReset4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 4."
|
|
::= { owEDS0090Entry 44 }
|
|
|
|
owEDS0090ActivityLatchReset5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 5."
|
|
::= { owEDS0090Entry 45 }
|
|
|
|
owEDS0090ActivityLatchReset6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 6."
|
|
::= { owEDS0090Entry 46 }
|
|
|
|
owEDS0090ActivityLatchReset7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 7."
|
|
::= { owEDS0090Entry 47 }
|
|
|
|
owEDS0090ActivityLatchReset8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 8."
|
|
::= { owEDS0090Entry 48 }
|
|
|
|
owEDS0090PulseCounterReset1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 1."
|
|
::= { owEDS0090Entry 49 }
|
|
|
|
owEDS0090PulseCounterReset2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 2."
|
|
::= { owEDS0090Entry 50 }
|
|
|
|
owEDS0090PulseCounterReset3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 3."
|
|
::= { owEDS0090Entry 51 }
|
|
|
|
owEDS0090PulseCounterReset4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 4."
|
|
::= { owEDS0090Entry 52 }
|
|
|
|
owEDS0090PulseCounterReset5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 5."
|
|
::= { owEDS0090Entry 53 }
|
|
|
|
owEDS0090PulseCounterReset6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 6."
|
|
::= { owEDS0090Entry 54 }
|
|
|
|
owEDS0090PulseCounterReset7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 7."
|
|
::= { owEDS0090Entry 55 }
|
|
|
|
owEDS0090PulseCounterReset8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 8."
|
|
::= { owEDS0090Entry 56 }
|
|
|
|
owEDS0090Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0090Entry 57 }
|
|
|
|
|
|
-- EDS0091 TABLE - quad opto
|
|
|
|
owEDS0091Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0091Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0091 device data (quad opto input)."
|
|
::= { owDevices 24 }
|
|
|
|
owEDS0091Entry OBJECT-TYPE
|
|
SYNTAX owEDS0091Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0091Table 1 }
|
|
|
|
owEDS0091Entry ::= SEQUENCE {
|
|
owEDS0091Input1
|
|
INTEGER,
|
|
owEDS0091Input2
|
|
INTEGER,
|
|
owEDS0091Input3
|
|
INTEGER,
|
|
owEDS0091Input4
|
|
INTEGER,
|
|
owEDS0091ActivityLatch1
|
|
INTEGER,
|
|
owEDS0091ActivityLatch2
|
|
INTEGER,
|
|
owEDS0091ActivityLatch3
|
|
INTEGER,
|
|
owEDS0091ActivityLatch4
|
|
INTEGER,
|
|
owEDS0091PulseCounter1
|
|
COUNTER32,
|
|
owEDS0091PulseCounter2
|
|
COUNTER32,
|
|
owEDS0091PulseCounter3
|
|
COUNTER32,
|
|
owEDS0091PulseCounter4
|
|
COUNTER32,
|
|
owEDS0091PulseCounterReset1
|
|
INTEGER,
|
|
owEDS0091PulseCounterReset2
|
|
INTEGER,
|
|
owEDS0091PulseCounterReset3
|
|
INTEGER,
|
|
owEDS0091PulseCounterReset4
|
|
INTEGER,
|
|
owEDS0091ActivityLatchReset1
|
|
INTEGER,
|
|
owEDS0091ActivityLatchReset2
|
|
INTEGER,
|
|
owEDS0091ActivityLatchReset3
|
|
INTEGER,
|
|
owEDS0091ActivityLatchReset4
|
|
INTEGER,
|
|
owEDS0091Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0091Input1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1."
|
|
::= { owEDS0091Entry 1 }
|
|
|
|
owEDS0091Input2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 2."
|
|
::= { owEDS0091Entry 2 }
|
|
|
|
owEDS0091Input3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 3."
|
|
::= { owEDS0091Entry 3 }
|
|
|
|
owEDS0091Input4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 4."
|
|
::= { owEDS0091Entry 4 }
|
|
|
|
owEDS0091ActivityLatch1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 1."
|
|
::= { owEDS0091Entry 5 }
|
|
|
|
owEDS0091ActivityLatch2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 2."
|
|
::= { owEDS0091Entry 6 }
|
|
|
|
owEDS0091ActivityLatch3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 3."
|
|
::= { owEDS0091Entry 7 }
|
|
|
|
owEDS0091ActivityLatch4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch 4."
|
|
::= { owEDS0091Entry 8 }
|
|
|
|
owEDS0091PulseCounter1 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 1."
|
|
::= { owEDS0091Entry 9 }
|
|
|
|
owEDS0091PulseCounter2 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 1."
|
|
::= { owEDS0091Entry 10 }
|
|
|
|
owEDS0091PulseCounter3 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 1."
|
|
::= { owEDS0091Entry 11 }
|
|
|
|
owEDS0091PulseCounter4 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter 1."
|
|
::= { owEDS0091Entry 12 }
|
|
|
|
owEDS0091PulseCounterReset1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 1."
|
|
::= { owEDS0091Entry 13 }
|
|
|
|
owEDS0091PulseCounterReset2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 2."
|
|
::= { owEDS0091Entry 14 }
|
|
|
|
owEDS0091PulseCounterReset3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 3."
|
|
::= { owEDS0091Entry 15 }
|
|
|
|
owEDS0091PulseCounterReset4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 4."
|
|
::= { owEDS0091Entry 16 }
|
|
|
|
owEDS0091ActivityLatchReset1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 1."
|
|
::= { owEDS0091Entry 17 }
|
|
|
|
owEDS0091ActivityLatchReset2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 2."
|
|
::= { owEDS0091Entry 18 }
|
|
|
|
owEDS0091ActivityLatchReset3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 3."
|
|
::= { owEDS0091Entry 19 }
|
|
|
|
owEDS0091ActivityLatchReset4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 4."
|
|
::= { owEDS0091Entry 20 }
|
|
|
|
|
|
owEDS0091Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0091Entry 21 }
|
|
|
|
-- EDS0092 TABLE - quad relay
|
|
|
|
owEDS0092Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF owEDS0092Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0092 device data (quad relay output)."
|
|
::= { owDevices 25 }
|
|
|
|
owEDS0092Entry OBJECT-TYPE
|
|
SYNTAX owEDS0092Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0092Table 1 }
|
|
|
|
owEDS0092Entry ::= SEQUENCE {
|
|
owEDS0092Output1
|
|
DisplayString,
|
|
owEDS0092Output2
|
|
DisplayString,
|
|
owEDS0092Output3
|
|
DisplayString,
|
|
owEDS0092Output4
|
|
DisplayString,
|
|
owEDS0092Counter
|
|
COUNTER32
|
|
}
|
|
|
|
owEDS0092Output1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 1."
|
|
::= { owEDS0092Entry 1 }
|
|
|
|
owEDS0092Output2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 2."
|
|
::= { owEDS0092Entry 2 }
|
|
|
|
owEDS0092Output3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 3."
|
|
::= { owEDS0092Entry 3 }
|
|
|
|
owEDS0092Output4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 4."
|
|
::= { owEDS0092Entry 4 }
|
|
|
|
owEDS0092Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0092Entry 5 }
|
|
|
|
|
|
|
|
-- DS28EA00 TABLE - Temp with PIO
|
|
|
|
owDS28EA00Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OwDS28EA00Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for DS28EA00 (1-wire
|
|
digital thermometer with PIO)."
|
|
::= { owDevices 26 }
|
|
|
|
owDS28EA00Entry OBJECT-TYPE
|
|
SYNTAX OwDS28EA00Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owDS28EA00Table 1 }
|
|
|
|
OwDS28EA00Entry ::= SEQUENCE {
|
|
owDS28EA00Temperature
|
|
DisplayString,
|
|
owDS28EA00UserByte1
|
|
INTEGER,
|
|
owDS28EA00UserByte2
|
|
INTEGER,
|
|
owDS28EA00PIOALevel
|
|
INTEGER,
|
|
owDS28EA00PIOBLevel
|
|
INTEGER,
|
|
owDS28EA00PIOAFlipFlop
|
|
INTEGER,
|
|
owDS28EA00PIOBFlipFlop
|
|
INTEGER,
|
|
}
|
|
|
|
owDS28EA00Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Current temperature from device, displayed as
|
|
a string with decimal point. Required since MIB's
|
|
cannot contain floating point numbers."
|
|
::= { owDS28EA00Entry 1 }
|
|
|
|
owDS28EA00UserByte1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "User byte 1 as read from EEPROM."
|
|
::= { owDS28EA00Entry 2 }
|
|
|
|
owDS28EA00UserByte2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "User byte 2 as read from EEPROM."
|
|
::= { owDS28EA00Entry 3 }
|
|
|
|
owDS28EA00PIOALevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "PIO-A logic level on pin. If PIO-A flip flop is
|
|
low, this input will always read low."
|
|
::= { owDS28EA00Entry 4 }
|
|
|
|
owDS28EA00PIOBLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "PIO-B logic level on pin. If PIO-B flip flop is
|
|
low, this input will always read low."
|
|
::= { owDS28EA00Entry 5 }
|
|
|
|
owDS28EA00PIOAFlipFlop OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "PIO-A Flip Flop. Sets output state of the
|
|
FF. The output is open collector, so the FF must
|
|
be high (1) to be able to read a pin state of
|
|
low (0)."
|
|
::= { owDS28EA00Entry 6 }
|
|
|
|
owDS28EA00PIOBFlipFlop OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "PIO-B Flip Flop. Sets output state of the
|
|
FF. The output is open collector, so the FF must
|
|
be high (1) to be able to read a pin state of
|
|
low (0)."
|
|
::= { owDS28EA00Entry 7 }
|
|
|
|
|
|
-- EDS0050 TABLE - Temp with PIO
|
|
|
|
owEDS0050Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OwEDS0050Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS0050 (Temp,
|
|
2 discrete, 1 analog (0-10v))."
|
|
::= { owDevices 27 }
|
|
|
|
owEDS0050Entry OBJECT-TYPE
|
|
SYNTAX OwEDS0050Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
INDEX {
|
|
owDeviceIndex
|
|
}
|
|
::= { owEDS0050Table 1 }
|
|
|
|
OwEDS0050Entry ::= SEQUENCE {
|
|
owEDS0050Temperature
|
|
DisplayString,
|
|
owEDS0050InputVoltage
|
|
DisplayString,
|
|
owEDS0050Input1
|
|
INTEGER,
|
|
|
|
owEDS0050Input2
|
|
|
|
INTEGER,
|
|
|
|
owEDS0050ActivityLatch1
|
|
INTEGER,
|
|
|
|
owEDS0050ActivityLatch2
|
|
|
|
INTEGER,
|
|
|
|
owEDS0050PulseCounter1
|
|
|
|
COUNTER32,
|
|
owEDS0050PulseCounter2
|
|
COUNTER32,
|
|
owEDS0050Output1
|
|
INTEGER,
|
|
owEDS0050Output2
|
|
INTEGER,
|
|
owEDS0050ActivityLatchReset1
|
|
INTEGER,
|
|
owEDS0050ActivityLatchReset2
|
|
INTEGER,
|
|
owEDS0050PulseCounterReset1
|
|
INTEGER,
|
|
owEDS0050PulseCounterReset2
|
|
INTEGER,
|
|
owEDS0050Counter
|
|
COUNTER32,
|
|
}
|
|
|
|
owEDS0050Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Current temperature from device, displayed as
|
|
a string with decimal point. Required since MIB's
|
|
cannot contain floating point numbers."
|
|
::= { owEDS0050Entry 1 }
|
|
|
|
owEDS0050InputVoltage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Voltage at the analog input."
|
|
::= { owEDS0050Entry 2 }
|
|
|
|
owEDS0050Input1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Discrete state at input 1."
|
|
::= { owEDS0050Entry 3 }
|
|
|
|
owEDS0050Input2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Discrete state at input 2."
|
|
::= { owEDS0050Entry 4 }
|
|
|
|
owEDS0050ActivityLatch1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Set to 1 if input has changed."
|
|
::= { owEDS0050Entry 5 }
|
|
|
|
owEDS0050ActivityLatch2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Set to 1 if input has changed."
|
|
::= { owEDS0050Entry 6 }
|
|
|
|
owEDS0050PulseCounter1 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Count of the pulses on input 1."
|
|
::= { owEDS0050Entry 7 }
|
|
|
|
owEDS0050PulseCounter2 OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Count of the pulses on input 2."
|
|
::= { owEDS0050Entry 8 }
|
|
|
|
owEDS0050Output1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 1."
|
|
::= { owEDS0050Entry 9 }
|
|
|
|
owEDS0050Output2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low( 0 ),
|
|
high( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output 2."
|
|
::= { owEDS0050Entry 10 }
|
|
|
|
owEDS0050ActivityLatchReset1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 1."
|
|
::= { owEDS0050Entry 11 }
|
|
|
|
owEDS0050ActivityLatchReset2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nofunction( 0 ),
|
|
reset( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity Latch Reset 2."
|
|
::= { owEDS0050Entry 12 }
|
|
|
|
owEDS0050PulseCounterReset1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 1."
|
|
::= { owEDS0050Entry 13 }
|
|
|
|
owEDS0050PulseCounterReset2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off( 0 ),
|
|
on( 1 )
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse Counter Reset 2."
|
|
::= { owEDS0050Entry 14 }
|
|
|
|
owEDS0050Counter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Counter."
|
|
::= { owEDS0050Entry 15 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
--Wireless device trap table
|
|
wTrap OBJECT IDENTIFIER ::= { edsMain 3 }
|
|
wTrapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF wTrapEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
::= { wTrap 1 }
|
|
|
|
wTrapEntry OBJECT-TYPE
|
|
SYNTAX wTrapEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
INDEX {
|
|
wTrapIndex
|
|
}
|
|
::= { wTrapTable 1 }
|
|
|
|
wTrapEntry ::= SEQUENCE {
|
|
wTrapIndex
|
|
INTEGER,
|
|
wTrapIP
|
|
IpAddress,
|
|
wTrapCommunity
|
|
INTEGER,
|
|
wTrapEUI
|
|
OCTET STRING,
|
|
wTrapVariable
|
|
OCTET STRING,
|
|
wTrapHighThreshold
|
|
DisplayString,
|
|
wTrapLowThreshold
|
|
DisplayString,
|
|
}
|
|
|
|
wTrapIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index of table. Traps are sent with this OID followed by the index
|
|
number of the table entry that generated the trap. An integer value is sent with the
|
|
trap which indicates what state change caused the trap. Using the
|
|
wTrapDeviceHighThreshold and wTrapDeviceLowThreshold
|
|
values, 3 windows are created. Transitions between
|
|
these windows generates a trap. The integer value indicates which
|
|
transition caused the trap as follows:
|
|
1 -> middle to high window transition
|
|
2 -> high to middle window transition
|
|
3 -> middle to low window transition
|
|
4 -> low to middle window transition
|
|
|
|
Note the following when programming traps:
|
|
1) Programming the HighThreshold lower than the LowThreshold is
|
|
invalid and will disable trap generation.
|
|
2) The wTrapEUI must be set to an active device or a trap
|
|
will not be sent.
|
|
3) The health of the device must be greater than 0 or no trap will
|
|
be sent.
|
|
4) The wTrapVariable must match one of the XML names."
|
|
::= { wTrapEntry 1 }
|
|
|
|
wTrapIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Address to send trap to."
|
|
::= { wTrapEntry 2 }
|
|
|
|
wTrapCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Community string to send with trap message."
|
|
::= { wTrapEntry 3 }
|
|
|
|
wTrapEUI OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Device EUI code to base sending trap message on."
|
|
::= { wTrapEntry 4 }
|
|
|
|
wTrapVariable OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Name of the variable, as stated in the XML file. For example, the name of humidity
|
|
for a EDS1068 is 'Humidity' (without the quotes)."
|
|
::= { wTrapEntry 5 }
|
|
|
|
wTrapHighThreshold OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "A trap will be generated when the variable is greater than this value or
|
|
less than or equal to this value. This number
|
|
may be positive or negative and may contain a decimal point."
|
|
::= { wTrapEntry 6 }
|
|
|
|
wTrapLowThreshold OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "A trap will be generated when the variable is less than this value or
|
|
greater than or equal to this value. This number
|
|
may be positive or negative and may contain a decimal point."
|
|
::= { wTrapEntry 7 }
|
|
|
|
|
|
|
|
--Wireless devices branch.
|
|
wDevices OBJECT IDENTIFIER ::= { edsMain 11 }
|
|
|
|
--Device type table (conceptual).
|
|
wDeviceTypes OBJECT IDENTIFIER ::= { wDevices 1 }
|
|
|
|
wNone OBJECT IDENTIFIER ::= { wDeviceTypes 0 }
|
|
|
|
wUnknown OBJECT IDENTIFIER ::= { wDeviceTypes 1 }
|
|
|
|
wUnused1 OBJECT IDENTIFIER ::= { wDeviceTypes 2 }
|
|
|
|
wUnused2 OBJECT IDENTIFIER ::= { wDeviceTypes 3 }
|
|
|
|
wEDS1068 OBJECT IDENTIFIER ::= { wDeviceTypes 4 }
|
|
|
|
wEDS1067 OBJECT IDENTIFIER ::= { wDeviceTypes 5 }
|
|
|
|
wEDS1066 OBJECT IDENTIFIER ::= { wDeviceTypes 6 }
|
|
|
|
wEDS1065 OBJECT IDENTIFIER ::= { wDeviceTypes 7 }
|
|
|
|
wEDS1064 OBJECT IDENTIFIER ::= { wDeviceTypes 8 }
|
|
|
|
wEDS1101 OBJECT IDENTIFIER ::= { wDeviceTypes 9 }
|
|
|
|
wEDS2101 OBJECT IDENTIFIER ::= { wDeviceTypes 10 }
|
|
|
|
wEDS2030 OBJECT IDENTIFIER ::= { wDeviceTypes 11 }
|
|
|
|
wDeviceInfo OBJECT IDENTIFIER ::= { wDevices 2 }
|
|
|
|
wDeviceNumActive OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number of currently active 1-wire devices. A device
|
|
is active if it's health is non-zero."
|
|
::= { wDeviceInfo 1 }
|
|
|
|
wDeviceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF wDeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
::= { wDevices 3 }
|
|
|
|
wDeviceEntry OBJECT-TYPE
|
|
SYNTAX wDeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
INDEX {
|
|
wDeviceIndex
|
|
}
|
|
::= { wDeviceTable 1 }
|
|
|
|
wDeviceEntry ::= SEQUENCE {
|
|
wDeviceIndex
|
|
INTEGER,
|
|
wDeviceType
|
|
INTEGER,
|
|
wDeviceName
|
|
DisplayString,
|
|
wDeviceDescription
|
|
DisplayString,
|
|
wDeviceFamily
|
|
INTEGER,
|
|
wDeviceEUI
|
|
OCTET STRING,
|
|
wDeviceHealth
|
|
INTEGER
|
|
wDeviceTag
|
|
DisplayString,
|
|
}
|
|
|
|
wDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Index of table."
|
|
::= { wDeviceEntry 1 }
|
|
|
|
wDeviceType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "An indication of the device type. This is the
|
|
last OID number to the wDeviceTypes group pointing
|
|
to the name of the device. The corresponding
|
|
device table will contain the specific information
|
|
from the device. For example: if this entry is
|
|
2 (owDS2406) then the table owDS2406Table, at
|
|
the appropriate index, will contain the data
|
|
from the device."
|
|
::= { wDeviceEntry 2 }
|
|
|
|
wDeviceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Name of the device."
|
|
::= { wDeviceEntry 3 }
|
|
|
|
wDeviceDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Text description of the device."
|
|
::= { wDeviceEntry 4 }
|
|
|
|
wDeviceFamily OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Family number."
|
|
::= { wDeviceEntry 5 }
|
|
|
|
wDeviceEUI OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Entire EUI as read from device."
|
|
::= { wDeviceEntry 6 }
|
|
|
|
wDeviceHealth OBJECT-TYPE
|
|
SYNTAX INTEGER (0..8)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Health of device. Ranges between 0 and 7 where
|
|
0 worst case and 7 is best case. Incremented
|
|
every time device responds to a search, decremented
|
|
if it does not respond."
|
|
::= { wDeviceEntry 7 }
|
|
|
|
wDeviceTag OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Tag from device."
|
|
::= { wDeviceEntry 8 }
|
|
|
|
|
|
-- EDS1068 TABLE
|
|
|
|
wEDS1068Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF wEDS1068Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS1068 device data (temperature, humidity, barometric pressure and light)."
|
|
::= { wDevices 4 }
|
|
|
|
wEDS1068Entry OBJECT-TYPE
|
|
SYNTAX wEDS1068Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
wDeviceIndex
|
|
}
|
|
::= { wEDS1068Table 1 }
|
|
|
|
wEDS1068Entry ::= SEQUENCE {
|
|
wEDS1068Temperature
|
|
DisplayString,
|
|
wEDS1068Humidity
|
|
DisplayString,
|
|
wEDS1068DewPoint
|
|
DisplayString,
|
|
wEDS1068Humidex
|
|
DisplayString,
|
|
wEDS1068HeatIndex
|
|
DisplayString,
|
|
wEDS1068BarometricPressure
|
|
DisplayString,
|
|
wEDS1068LEDState
|
|
INTEGER,
|
|
wEDS1068RelayState
|
|
INTEGER,
|
|
wEDS1068Light
|
|
DisplayString,
|
|
wEDS1068Input1
|
|
INTEGER,
|
|
wEDS1068ActivityLatch1
|
|
INTEGER,
|
|
wEDS1068PulseCounter1
|
|
COUNTER32,
|
|
wEDS1068Battery
|
|
DisplayString,
|
|
wEDS1068ReadCounter
|
|
COUNTER32,
|
|
wEDS1068LEDFunction
|
|
INTEGER,
|
|
wEDS1068RelayFunction
|
|
INTEGER,
|
|
wEDS1068LEDSetState
|
|
INTEGER,
|
|
wEDS1068RelaySetState
|
|
INTEGER,
|
|
}
|
|
|
|
wEDS1068Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { wEDS1068Entry 1 }
|
|
|
|
wEDS1068Humidity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Humidity."
|
|
::= { wEDS1068Entry 2 }
|
|
|
|
wEDS1068DewPoint OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "DewPoint."
|
|
::= { wEDS1068Entry 3 }
|
|
|
|
wEDS1068Humidex OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Humidex."
|
|
::= { wEDS1068Entry 4 }
|
|
|
|
wEDS1068HeatIndex OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Heat Index."
|
|
::= { wEDS1068Entry 5 }
|
|
|
|
wEDS1068BarometricPressure OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Barometric Pressure in Millibars."
|
|
::= { wEDS1068Entry 6 }
|
|
|
|
wEDS1068LEDState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "LED state."
|
|
::= { wEDS1068Entry 7 }
|
|
|
|
wEDS1068RelayState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay state."
|
|
::= { wEDS1068Entry 8 }
|
|
|
|
wEDS1068Light OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Light."
|
|
::= { wEDS1068Entry 9 }
|
|
|
|
wEDS1068Input1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1 state."
|
|
::= { wEDS1068Entry 10 }
|
|
|
|
wEDS1068ActivityLatch1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity latch 1 state."
|
|
::= { wEDS1068Entry 11 }
|
|
|
|
wEDS1068PulseCounter1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse counter 1."
|
|
::= { wEDS1068Entry 12 }
|
|
|
|
wEDS1068Battery OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Battery voltage."
|
|
::= { wEDS1068Entry 13 }
|
|
|
|
wEDS1068ReadCounter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Read counter."
|
|
::= { wEDS1068Entry 14 }
|
|
|
|
wEDS1068LEDFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED function."
|
|
::= { wEDS1068Entry 15 }
|
|
|
|
wEDS1068RelayFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay function."
|
|
::= { wEDS1068Entry 16 }
|
|
|
|
wEDS1068LEDSetState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED set state."
|
|
::= { wEDS1068Entry 17 }
|
|
|
|
wEDS1068RelaySetState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay set state."
|
|
::= { wEDS1068Entry 18 }
|
|
|
|
-- EDS1067 TABLE, temp, light, input, relay
|
|
|
|
wEDS1067Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF wEDS1067Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS1067 device data (temperature, humidity, barometric pressure and light)."
|
|
::= { wDevices 5 }
|
|
|
|
wEDS1067Entry OBJECT-TYPE
|
|
SYNTAX wEDS1067Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
wDeviceIndex
|
|
}
|
|
::= { wEDS1067Table 1 }
|
|
|
|
wEDS1067Entry ::= SEQUENCE {
|
|
wEDS1067Temperature
|
|
DisplayString,
|
|
wEDS1067LEDState
|
|
INTEGER,
|
|
wEDS1067RelayState
|
|
INTEGER,
|
|
wEDS1067Light
|
|
DisplayString,
|
|
wEDS1067Input1
|
|
INTEGER,
|
|
wEDS1067ActivityLatch1
|
|
INTEGER,
|
|
wEDS1067PulseCounter1
|
|
COUNTER32,
|
|
wEDS1067Battery
|
|
DisplayString,
|
|
wEDS1067ReadCounter
|
|
COUNTER32,
|
|
wEDS1067LEDFunction
|
|
INTEGER,
|
|
wEDS1067RelayFunction
|
|
INTEGER,
|
|
wEDS1067LEDSetState
|
|
INTEGER,
|
|
wEDS1067RelaySetState
|
|
INTEGER,
|
|
}
|
|
|
|
wEDS1067Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { wEDS1067Entry 1 }
|
|
|
|
wEDS1067LEDState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "LED state."
|
|
::= { wEDS1067Entry 2 }
|
|
|
|
wEDS1067RelayState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay state."
|
|
::= { wEDS1067Entry 3 }
|
|
|
|
wEDS1067Light OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Light."
|
|
::= { wEDS1067Entry 4 }
|
|
|
|
wEDS1067Input1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1 state."
|
|
::= { wEDS1067Entry 5 }
|
|
|
|
wEDS1067ActivityLatch1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity latch 1 state."
|
|
::= { wEDS1067Entry 6 }
|
|
|
|
wEDS1067PulseCounter1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse counter 1."
|
|
::= { wEDS1067Entry 7 }
|
|
|
|
wEDS1067Battery OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Battery voltage."
|
|
::= { wEDS1067Entry 8 }
|
|
|
|
wEDS1067ReadCounter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Read counter."
|
|
::= { wEDS1067Entry 9 }
|
|
|
|
wEDS1067LEDFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED function."
|
|
::= { wEDS1067Entry 10 }
|
|
|
|
wEDS1067RelayFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay function."
|
|
::= { wEDS1067Entry 11 }
|
|
|
|
wEDS1067LEDSetState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED set state."
|
|
::= { wEDS1067Entry 12 }
|
|
|
|
wEDS1067RelaySetState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay set state."
|
|
::= { wEDS1067Entry 13 }
|
|
|
|
-- EDS1066 TABLE, temp, BP, input, relay
|
|
|
|
wEDS1066Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF wEDS1066Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS1066 device data (temperature, humidity, barometric pressure and light)."
|
|
::= { wDevices 6 }
|
|
|
|
wEDS1066Entry OBJECT-TYPE
|
|
SYNTAX wEDS1066Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
wDeviceIndex
|
|
}
|
|
::= { wEDS1066Table 1 }
|
|
|
|
wEDS1066Entry ::= SEQUENCE {
|
|
wEDS1066Temperature
|
|
DisplayString,
|
|
wEDS1066BarometricPressure
|
|
DisplayString,
|
|
wEDS1066LEDState
|
|
INTEGER,
|
|
wEDS1066RelayState
|
|
INTEGER,
|
|
wEDS1066Input1
|
|
INTEGER,
|
|
wEDS1066ActivityLatch1
|
|
INTEGER,
|
|
wEDS1066PulseCounter1
|
|
COUNTER32,
|
|
wEDS1066Battery
|
|
DisplayString,
|
|
wEDS1066ReadCounter
|
|
COUNTER32,
|
|
wEDS1066LEDFunction
|
|
INTEGER,
|
|
wEDS1066RelayFunction
|
|
INTEGER,
|
|
wEDS1066LEDSetState
|
|
INTEGER,
|
|
wEDS1066RelaySetState
|
|
INTEGER,
|
|
}
|
|
|
|
wEDS1066Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { wEDS1066Entry 1 }
|
|
|
|
wEDS1066BarometricPressure OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Barometric Pressure in Millibars."
|
|
::= { wEDS1066Entry 2 }
|
|
|
|
wEDS1066LEDState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "LED state."
|
|
::= { wEDS1066Entry 3 }
|
|
|
|
wEDS1066RelayState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay state."
|
|
::= { wEDS1066Entry 4 }
|
|
|
|
wEDS1066Input1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1 state."
|
|
::= { wEDS1066Entry 5 }
|
|
|
|
wEDS1066ActivityLatch1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity latch 1 state."
|
|
::= { wEDS1066Entry 6 }
|
|
|
|
wEDS1066PulseCounter1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse counter 1."
|
|
::= { wEDS1066Entry 7 }
|
|
|
|
wEDS1066Battery OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Battery voltage."
|
|
::= { wEDS1066Entry 8 }
|
|
|
|
wEDS1066ReadCounter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Read counter."
|
|
::= { wEDS1066Entry 9 }
|
|
|
|
wEDS1066LEDFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED function."
|
|
::= { wEDS1066Entry 10 }
|
|
|
|
wEDS1066RelayFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay function."
|
|
::= { wEDS1066Entry 11 }
|
|
|
|
wEDS1066LEDSetState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED set state."
|
|
::= { wEDS1066Entry 12 }
|
|
|
|
wEDS1066RelaySetState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay set state."
|
|
::= { wEDS1066Entry 13 }
|
|
|
|
-- EDS1065 TABLE, temp, hum, input, relay
|
|
|
|
wEDS1065Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF wEDS1065Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS1065 device data (temperature, humidity, barometric pressure and light)."
|
|
::= { wDevices 7 }
|
|
|
|
wEDS1065Entry OBJECT-TYPE
|
|
SYNTAX wEDS1065Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
wDeviceIndex
|
|
}
|
|
::= { wEDS1065Table 1 }
|
|
|
|
wEDS1065Entry ::= SEQUENCE {
|
|
wEDS1065Temperature
|
|
DisplayString,
|
|
wEDS1065Humidity
|
|
DisplayString,
|
|
wEDS1065DewPoint
|
|
DisplayString,
|
|
wEDS1065Humidex
|
|
DisplayString,
|
|
wEDS1065HeatIndex
|
|
DisplayString,
|
|
wEDS1065LEDState
|
|
INTEGER,
|
|
wEDS1065RelayState
|
|
INTEGER,
|
|
wEDS1065Input1
|
|
INTEGER,
|
|
wEDS1065ActivityLatch1
|
|
INTEGER,
|
|
wEDS1065PulseCounter1
|
|
COUNTER32,
|
|
wEDS1065Battery
|
|
DisplayString,
|
|
wEDS1065ReadCounter
|
|
COUNTER32,
|
|
wEDS1065LEDFunction
|
|
INTEGER,
|
|
wEDS1065RelayFunction
|
|
INTEGER,
|
|
wEDS1065LEDSetState
|
|
INTEGER,
|
|
wEDS1065RelaySetState
|
|
INTEGER,
|
|
}
|
|
|
|
wEDS1065Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { wEDS1065Entry 1 }
|
|
|
|
wEDS1065Humidity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Humidity."
|
|
::= { wEDS1065Entry 2 }
|
|
|
|
wEDS1065DewPoint OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "DewPoint."
|
|
::= { wEDS1065Entry 3 }
|
|
|
|
wEDS1065Humidex OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Humidex."
|
|
::= { wEDS1065Entry 4 }
|
|
|
|
wEDS1065HeatIndex OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Heat Index."
|
|
::= { wEDS1065Entry 5 }
|
|
|
|
wEDS1065LEDState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "LED state."
|
|
::= { wEDS1065Entry 6 }
|
|
|
|
wEDS1065RelayState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay state."
|
|
::= { wEDS1065Entry 7 }
|
|
|
|
wEDS1065Input1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1 state."
|
|
::= { wEDS1065Entry 8 }
|
|
|
|
wEDS1065ActivityLatch1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity latch 1 state."
|
|
::= { wEDS1065Entry 9 }
|
|
|
|
wEDS1065PulseCounter1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse counter 1."
|
|
::= { wEDS1065Entry 10 }
|
|
|
|
wEDS1065Battery OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Battery voltage."
|
|
::= { wEDS1065Entry 11 }
|
|
|
|
wEDS1065ReadCounter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Read counter."
|
|
::= { wEDS1065Entry 12 }
|
|
|
|
wEDS1065LEDFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED function."
|
|
::= { wEDS1065Entry 13 }
|
|
|
|
wEDS1065RelayFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay function."
|
|
::= { wEDS1065Entry 14 }
|
|
|
|
wEDS1065LEDSetState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED set state."
|
|
::= { wEDS1065Entry 15 }
|
|
|
|
wEDS1065RelaySetState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay set state."
|
|
::= { wEDS1065Entry 16 }
|
|
|
|
-- EDS1064 TABLE, temp, input, relay
|
|
|
|
wEDS1064Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF wEDS1064Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS1064 device data (temperature, humidity, barometric pressure and light)."
|
|
::= { wDevices 8 }
|
|
|
|
wEDS1064Entry OBJECT-TYPE
|
|
SYNTAX wEDS1064Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
wDeviceIndex
|
|
}
|
|
::= { wEDS1064Table 1 }
|
|
|
|
wEDS1064Entry ::= SEQUENCE {
|
|
wEDS1064Temperature
|
|
DisplayString,
|
|
wEDS1064LEDState
|
|
INTEGER,
|
|
wEDS1064RelayState
|
|
INTEGER,
|
|
wEDS1064Input1
|
|
INTEGER,
|
|
wEDS1064ActivityLatch1
|
|
INTEGER,
|
|
wEDS1064PulseCounter1
|
|
COUNTER32,
|
|
wEDS1064Battery
|
|
DisplayString,
|
|
wEDS1064ReadCounter
|
|
COUNTER32,
|
|
wEDS1064LEDFunction
|
|
INTEGER,
|
|
wEDS1064RelayFunction
|
|
INTEGER,
|
|
wEDS1064LEDSetState
|
|
INTEGER,
|
|
wEDS1064RelaySetState
|
|
INTEGER,
|
|
}
|
|
|
|
wEDS1064Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { wEDS1064Entry 1 }
|
|
|
|
wEDS1064LEDState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "LED state."
|
|
::= { wEDS1064Entry 2 }
|
|
|
|
wEDS1064RelayState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay state."
|
|
::= { wEDS1064Entry 3 }
|
|
|
|
wEDS1064Input1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1 state."
|
|
::= { wEDS1064Entry 4 }
|
|
|
|
wEDS1064ActivityLatch1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity latch 1 state."
|
|
::= { wEDS1064Entry 5 }
|
|
|
|
wEDS1064PulseCounter1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse counter 1."
|
|
::= { wEDS1064Entry 6 }
|
|
|
|
wEDS1064Battery OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Battery voltage."
|
|
::= { wEDS1064Entry 7 }
|
|
|
|
wEDS1064ReadCounter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Read counter."
|
|
::= { wEDS1064Entry 8 }
|
|
|
|
wEDS1064LEDFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED function."
|
|
::= { wEDS1064Entry 9 }
|
|
|
|
wEDS1064RelayFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay function."
|
|
::= { wEDS1064Entry 10 }
|
|
|
|
wEDS1064LEDSetState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED set state."
|
|
::= { wEDS1064Entry 11 }
|
|
|
|
wEDS1064RelaySetState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Relay set state."
|
|
::= { wEDS1064Entry 12 }
|
|
|
|
-- EDS1101 TABLE
|
|
|
|
wEDS1101Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF wEDS1101Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS1101 device data (repeater)."
|
|
::= { wDevices 9 }
|
|
|
|
wEDS1101Entry OBJECT-TYPE
|
|
SYNTAX wEDS1101Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
wDeviceIndex
|
|
}
|
|
::= { wEDS1101Table 1 }
|
|
|
|
wEDS1101Entry ::= SEQUENCE {
|
|
wEDS1101DevicesConnected
|
|
INTEGER,
|
|
wEDS1101SendCounter
|
|
COUNTER32,
|
|
}
|
|
|
|
wEDS1101DevicesConnected OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number of devices connected."
|
|
::= { wEDS1101Entry 1 }
|
|
|
|
wEDS1101SendCounter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Send counter."
|
|
::= { wEDS1101Entry 2 }
|
|
|
|
-- EDS2101 TABLE
|
|
|
|
wEDS2101Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF wEDS2101Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS2101 device data (repeater)."
|
|
::= { wDevices 10 }
|
|
|
|
wEDS2101Entry OBJECT-TYPE
|
|
SYNTAX wEDS2101Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
wDeviceIndex
|
|
}
|
|
::= { wEDS2101Table 1 }
|
|
|
|
wEDS2101Entry ::= SEQUENCE {
|
|
wEDS2101DevicesConnected
|
|
INTEGER,
|
|
wEDS2101SendCounter
|
|
COUNTER32,
|
|
}
|
|
|
|
wEDS2101DevicesConnected OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number of devices connected."
|
|
::= { wEDS2101Entry 1 }
|
|
|
|
wEDS2101SendCounter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Send counter."
|
|
::= { wEDS2101Entry 2 }
|
|
|
|
|
|
-- EDS2030 TABLE
|
|
|
|
wEDS2030Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF wEDS2030Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Table for EDS2030 device data (temperature, probe, light and input)."
|
|
::= { wDevices 11 }
|
|
|
|
wEDS2030Entry OBJECT-TYPE
|
|
SYNTAX wEDS2030Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX {
|
|
wDeviceIndex
|
|
}
|
|
::= { wEDS2030Table 1 }
|
|
|
|
wEDS2030Entry ::= SEQUENCE {
|
|
wEDS2030Temperature
|
|
DisplayString,
|
|
wEDS2030Probe
|
|
DisplayString,
|
|
wEDS2030LEDState
|
|
INTEGER,
|
|
wEDS2030Light
|
|
DisplayString,
|
|
wEDS2030Input1
|
|
INTEGER,
|
|
wEDS2030ActivityLatch1
|
|
INTEGER,
|
|
wEDS2030PulseCounter1
|
|
COUNTER32,
|
|
wEDS2030Battery
|
|
DisplayString,
|
|
wEDS2030ReadCounter
|
|
COUNTER32,
|
|
wEDS2030LEDFunction
|
|
INTEGER,
|
|
wEDS2030LEDSetState
|
|
INTEGER,
|
|
}
|
|
|
|
wEDS2030Temperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature."
|
|
::= { wEDS2030Entry 1 }
|
|
|
|
wEDS2030Probe OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature probe."
|
|
::= { wEDS2030Entry 2 }
|
|
|
|
wEDS2030LEDState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "LED state."
|
|
::= { wEDS2030Entry 3 }
|
|
|
|
wEDS2030Light OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Light."
|
|
::= { wEDS2030Entry 4 }
|
|
|
|
wEDS2030Input1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input 1 state."
|
|
::= { wEDS2030Entry 5 }
|
|
|
|
wEDS2030ActivityLatch1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Activity latch 1 state."
|
|
::= { wEDS2030Entry 6 }
|
|
|
|
wEDS2030PulseCounter1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Pulse counter 1."
|
|
::= { wEDS2030Entry 7 }
|
|
|
|
wEDS2030Battery OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Battery voltage."
|
|
::= { wEDS2030Entry 8 }
|
|
|
|
wEDS2030ReadCounter OBJECT-TYPE
|
|
SYNTAX COUNTER32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Read counter."
|
|
::= { wEDS2030Entry 9 }
|
|
|
|
wEDS2030LEDFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED function."
|
|
::= { wEDS2030Entry 10 }
|
|
|
|
wEDS2030LEDSetState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LED set state."
|
|