- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
700 lines
28 KiB
Text
700 lines
28 KiB
Text
-- *****************************************************************
|
|
-- DLINKSW-POE-MIB.mib : D-Link extensions to POWER-ETHERNET-MIB (PoE)
|
|
--
|
|
-- Copyright (c) 2017 D-Link Corporation, all rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
DLINKSW-POE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DisplayString,TruthValue
|
|
FROM SNMPv2-TC
|
|
InetAddressType, InetAddress
|
|
FROM INET-ADDRESS-MIB
|
|
PortList
|
|
FROM Q-BRIDGE-MIB
|
|
pethMainPseGroupIndex, pethPsePortIndex, pethPsePortShortCounter,
|
|
pethPsePortOverLoadCounter, pethPsePortPowerDeniedCounter
|
|
FROM POWER-ETHERNET-MIB
|
|
dlinkIndustrialCommon
|
|
FROM DLINK-ID-REC-MIB;
|
|
|
|
|
|
dlinkSwPoeExtMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201703150000Z"
|
|
ORGANIZATION "D-Link Corp."
|
|
CONTACT-INFO
|
|
" D-Link Corporation
|
|
Postal: No. 289, Sinhu 3rd Rd., Neihu District,
|
|
Taipei City 114, Taiwan, R.O.C
|
|
Tel: +886-2-66000123
|
|
E-mail: tsd@dlink.com.tw
|
|
"
|
|
DESCRIPTION
|
|
"A MIB module for extending POWER-ETHERNET-MIB specified in
|
|
RFC 3621.
|
|
"
|
|
REVISION "201305290000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
REVISION "201309240000Z"
|
|
DESCRIPTION
|
|
"Add dPoeGroupIfLedMode node."
|
|
REVISION "201703150000Z"
|
|
DESCRIPTION
|
|
"Add dPoeIfPdAliveCfgTable table to support PD alive check feature."
|
|
::= { dlinkIndustrialCommon 24 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
dPoeMIBNotifications OBJECT IDENTIFIER ::= { dlinkSwPoeExtMIB 0 }
|
|
dPoeMIBObjects OBJECT IDENTIFIER ::= { dlinkSwPoeExtMIB 1 }
|
|
dPoeMIBConformance OBJECT IDENTIFIER ::= { dlinkSwPoeExtMIB 2 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
dPoeGroupCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoeGroupCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of group configurations for PoE.
|
|
Group means box in the stack or module in a rack.
|
|
For non-modular devices, the pethMainPseGroupIndex is 1.
|
|
"
|
|
::= { dPoeMIBObjects 1 }
|
|
|
|
dPoeGroupCfgEntry OBJECT-TYPE
|
|
SYNTAX DPoeGroupCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry contains the system configuration of the PoE on a group."
|
|
INDEX { pethMainPseGroupIndex }
|
|
::= { dPoeGroupCfgTable 1 }
|
|
|
|
DPoeGroupCfgEntry ::= SEQUENCE {
|
|
dPoeGroupPolicyPreempt TruthValue,
|
|
dPoeGroupClearIfStatistic PortList,
|
|
dPoeGroupIfLedMode INTEGER
|
|
}
|
|
|
|
dPoeGroupPolicyPreempt OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object configures whether to disconnect the PD which is powered
|
|
with lower priority in order to release the power to the new connected
|
|
PD with higher priority under power shortage condition.
|
|
If this object is 'false', then the policy is first in first serviced.
|
|
Thus the new PD will not be serviced if the power budget is running out.
|
|
If this object is 'true', then the power provisioned to PD
|
|
with lower priority can be preempted to release the power to the new
|
|
connected PD with higher priority. "
|
|
DEFVAL { false }
|
|
::= { dPoeGroupCfgEntry 1 }
|
|
|
|
dPoeGroupClearIfStatistic OBJECT-TYPE
|
|
SYNTAX PortList
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to clear the PoE statistics of pethPsePortEntry
|
|
for specified ports.
|
|
"
|
|
::= { dPoeGroupCfgEntry 2 }
|
|
|
|
dPoeGroupIfLedMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
poeMode(1),
|
|
linkMode(2),
|
|
invalid(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For some devices,port LED can indicate either poe status or link status.
|
|
This object is used to configure or display port LED mode.
|
|
poeMode(1) - indicates poe status.
|
|
linkMode(2) - indicates link status.
|
|
|
|
For other devices have LEDs to indicate poe status and link status separately,
|
|
this object only can get value of invalid(3) to mean this node is meaningless.
|
|
"
|
|
::= { dPoeGroupCfgEntry 3 }
|
|
-------------------------------------------------------------------------------
|
|
dPoeGroupInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoEGroupInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of PoE information for groups."
|
|
::= { dPoeMIBObjects 2 }
|
|
|
|
dPoeGroupInfoEntry OBJECT-TYPE
|
|
SYNTAX DPoEGroupInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry contains the system information of the PoE on a group."
|
|
INDEX { pethMainPseGroupIndex }
|
|
::= { dPoeGroupInfoTable 1 }
|
|
|
|
DPoEGroupInfoEntry ::= SEQUENCE {
|
|
dPoeGroupMaxPorts Integer32,
|
|
dPoeGroupHWVersion DisplayString,
|
|
dPoeGroupSWVersion DisplayString
|
|
}
|
|
|
|
dPoeGroupMaxPorts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the maximum number of ports that the group can support."
|
|
::= { dPoeGroupInfoEntry 1 }
|
|
|
|
dPoeGroupHWVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates H/W version of PoE chip."
|
|
::= { dPoeGroupInfoEntry 2 }
|
|
|
|
dPoeGroupSWVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates firmware version of PoE chip."
|
|
::= { dPoeGroupInfoEntry 3 }
|
|
|
|
------------------------------------------------------------------------------------------------------
|
|
dPoeIfObjects OBJECT IDENTIFIER ::= { dPoeMIBObjects 3 }
|
|
|
|
dPoeIfCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoeIfCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of PoE configuration
|
|
information for ports."
|
|
::= { dPoeIfObjects 1 }
|
|
|
|
dPoeIfCfgEntry OBJECT-TYPE
|
|
SYNTAX DPoeIfCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry contains PoE configuration on a port."
|
|
INDEX {
|
|
pethMainPseGroupIndex,
|
|
pethPsePortIndex
|
|
}
|
|
::= { dPoeIfCfgTable 1 }
|
|
|
|
DPoeIfCfgEntry ::= SEQUENCE {
|
|
dPoeIfState INTEGER,
|
|
dPoeIfMaxPower Integer32,
|
|
dPoeIfTimeRange DisplayString,
|
|
dPoeIfLegacyPdEnabled TruthValue
|
|
}
|
|
|
|
dPoeIfState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto(1),
|
|
never(2),
|
|
static(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the PoE state of the entry.
|
|
auto(1) - the port will automatically detect the PD and provision
|
|
power to the PD. The max wattage value which can be provisioned
|
|
to the port is determined by dPoeIfMaxPower. If dPoeIfMaxPower
|
|
is unspecified, then the class of the PD auto determines the
|
|
maximum wattage which can be provisioned. The PD will not be
|
|
provisioned if it requests more wattage than the max wattage
|
|
which is determined.
|
|
never(2) - indicates the port will not supply power to connected PD;
|
|
static(3) - indicates manager pre-allocate power budget to the port
|
|
by configuring the dPoeIfMaxPower object. The power budget is allocated
|
|
to the port even though there is no PD connected to the port.
|
|
If dPoeIfMaxPower is not configured, default value is 15400mW for 802.3af
|
|
and 30000mW for 802.3at."
|
|
DEFVAL {auto}
|
|
::= { dPoeIfCfgEntry 1 }
|
|
|
|
dPoeIfMaxPower OBJECT-TYPE
|
|
SYNTAX Integer32( 0 | 1000..30000)
|
|
UNITS "milliwatts"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the max wattage value which can
|
|
be provisioned to the port.
|
|
Note: This object is valid only while the dPoeIfState
|
|
object is configured as auto or static."
|
|
::= { dPoeIfCfgEntry 2 }
|
|
|
|
dPoeIfTimeRange OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the name of time-range profile to delineate
|
|
the activation period.
|
|
A zero length string indicates the time-range is not specified.
|
|
Note: This object is valid only while the dPoeIfState is 'auto'."
|
|
::= { dPoeIfCfgEntry 3 }
|
|
|
|
dPoeIfLegacyPdEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the state of legacy PD support."
|
|
DEFVAL { false }
|
|
::= { dPoeIfCfgEntry 4 }
|
|
|
|
------------------------------------------------------------------------------------------------------
|
|
dPoeIfInfoObjects OBJECT IDENTIFIER ::= { dPoeIfObjects 2 }
|
|
|
|
dPoeIfStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoeIfStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of PoE status for ports."
|
|
::= { dPoeIfInfoObjects 1 }
|
|
|
|
dPoeIfStatusEntry OBJECT-TYPE
|
|
SYNTAX DPoeIfStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry consists of PoE status for a port."
|
|
INDEX { pethMainPseGroupIndex,pethPsePortIndex }
|
|
::= { dPoeIfStatusTable 1 }
|
|
|
|
DPoeIfStatusEntry ::= SEQUENCE {
|
|
dPoeIfDetectStatus INTEGER,
|
|
dPoeIfFaultyType INTEGER
|
|
}
|
|
|
|
dPoeIfDetectStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
searching(2),
|
|
requesting(3),
|
|
delivering(4),
|
|
faulty(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the operational status of the port PD detection.
|
|
disabled(1) - PSE function is disabled.
|
|
searching(2) - Remote PD is not connected.
|
|
requesting(3) - Remote PD is inserted, but the PSE doesn't provide power yet.
|
|
delivering(4) - Remote PD is now powering by PoE system.
|
|
faulty(5) - Device detection or a powered device is in a faulty state.
|
|
"
|
|
::= { dPoeIfStatusEntry 1 }
|
|
|
|
dPoeIfFaultyType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(0),
|
|
mpsAbsent(1),
|
|
pdShort(2),
|
|
overload(3),
|
|
powerDenied(4),
|
|
thermalShutdown(5),
|
|
startupFailure(6),
|
|
classificationFailure(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the specific faulty type. It is meaningful
|
|
only when dPoeIfDetectStatus object is 'faulty'.
|
|
notApplicable(0) - indicates this object is meaningless, e.g. the
|
|
dPoeIfDetectStatus is not 'faulty'.
|
|
mpsAbsent(1) - indicates MPS(Maintain Power Signature) Absent
|
|
pdShort(2) - indicates PD Short
|
|
overload(3) - indicates Overload
|
|
powerDenied(4) - indicates Power Denied
|
|
thermalShutdown(5)- indicates Thermal Shutdown
|
|
startupFailure(6) - indicates Startup Failure
|
|
classificationFailure(7) - indicates Classification Failure(IEEE 802.3at)
|
|
"
|
|
::= { dPoeIfStatusEntry 2 }
|
|
|
|
------------------------------------------------------------------------------------------------------
|
|
dPoeIfMeasurementTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoEIfMeasurementEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of POE measurement
|
|
information for ports."
|
|
::= { dPoeIfInfoObjects 2 }
|
|
|
|
dPoeIfMeasurementEntry OBJECT-TYPE
|
|
SYNTAX DPoEIfMeasurementEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry consists of PoE measurement information of a port."
|
|
INDEX {
|
|
pethMainPseGroupIndex,
|
|
pethPsePortIndex
|
|
}
|
|
::= { dPoeIfMeasurementTable 1 }
|
|
|
|
DPoEIfMeasurementEntry ::= SEQUENCE {
|
|
dPoeIfVoltage Integer32,
|
|
dPoeIfCurrent Integer32,
|
|
dPoeIfTemperature Integer32,
|
|
dPoeIfPower Integer32
|
|
}
|
|
|
|
dPoeIfVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "millivolts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the voltage of the port in millivolts."
|
|
::= { dPoeIfMeasurementEntry 1 }
|
|
|
|
dPoeIfCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milliamperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the current of port in milliamperes."
|
|
::= { dPoeIfMeasurementEntry 2 }
|
|
|
|
dPoeIfTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Degree Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the temperature of port in degrees centigrade."
|
|
::= { dPoeIfMeasurementEntry 3 }
|
|
|
|
dPoeIfPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates consumption power of port in milliwatts."
|
|
::= { dPoeIfMeasurementEntry 4 }
|
|
|
|
---------------------------------------------------------------------------------
|
|
-- Add a new table for SNR-20170223-001(ASV2.1)(PD alive check)
|
|
---------------------------------------------------------------------------------
|
|
dPoeIfPdAliveCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoeIfPdAliveCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of configuration for the PD
|
|
alive check function for ports.
|
|
The PD alive check feature provides the solution for
|
|
PD device that has the stop working or no response
|
|
problem via Ping mechanism.
|
|
Detailed Process:
|
|
The detailed processes are described as follows:
|
|
1. The system needs to periodically monitor the
|
|
specific PD by using Ping function. If there is no
|
|
response, system takes one of the following actions:
|
|
(1) Reset: Switch resets (disable then enable) PoE
|
|
power on the port which connects to a PD under monitoring.
|
|
(2) Notify: Switch sends logs and traps to notify the administrator.
|
|
(3) Both: Switch sends logs and traps, and resets the PoE port power.
|
|
2. The system should implement the retry mechanism to check
|
|
PD aliveness, hence the system will reset the PoE port power
|
|
feeding after the retry by using Ping without any response from a PD.
|
|
3. If the action is Reset or Both, the system needs
|
|
to wait for PD recovery from rebooting and then executes
|
|
the Ping function again. Besides, the waiting time can
|
|
be configured by users.
|
|
4. If PoE schedule (time range) function is configured
|
|
on the port which enables the PD Alive Check function,
|
|
the time range function has the top priority, and
|
|
therefore PD Alive Check function will not work
|
|
while PoE time range function is still active.
|
|
5. This function only takes effect on PoE enabled
|
|
port with power feeding.
|
|
|
|
Note: It is required to setup IP settings properly that
|
|
the PD can be reachable for Ping, otherwise this function
|
|
cannot work as expected.
|
|
|
|
Limitation
|
|
1. Support Ping Function: If the PD does not support ICMP,
|
|
this function cannot work normally.
|
|
2. Direct-Connected PD: The Reset Action can only work on
|
|
the direct-connected PD. If the PD is not connected directly,
|
|
the Reset Action may not work as expected.
|
|
3. PD Also Acts as PSE: If the direct-connected PD is also a PSE,
|
|
all the next level PDs connect to this PSE will be power cycling
|
|
whenever PD Alive Check function takes effect on 'Reset' or 'Both' Action."
|
|
::= { dPoeIfObjects 3 }
|
|
|
|
dPoeIfPdAliveCfgEntry OBJECT-TYPE
|
|
SYNTAX DPoeIfPdAliveCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry contains configuration for PD alive check on a port."
|
|
INDEX {
|
|
pethMainPseGroupIndex,
|
|
pethPsePortIndex
|
|
}
|
|
::= { dPoeIfPdAliveCfgTable 1 }
|
|
|
|
DPoeIfPdAliveCfgEntry ::= SEQUENCE {
|
|
dPoeIfPdAliveCfgState INTEGER,
|
|
dPoeIfPdAliveCfgPdIpType InetAddressType,
|
|
dPoeIfPdAliveCfgPdIpAddr InetAddress,
|
|
dPoeIfPdAliveCfgInterval Unsigned32,
|
|
dPoeIfPdAliveCfgRetry Unsigned32,
|
|
dPoeIfPdAliveCfgWaitTime Unsigned32,
|
|
dPoeIfPdAliveCfgAction INTEGER
|
|
}
|
|
|
|
dPoeIfPdAliveCfgState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the the PD alive function sate.
|
|
enabled - Enable the PD alive check function
|
|
disabled - Disable the PD alive check function.
|
|
|
|
"
|
|
DEFVAL { disabled }
|
|
::= { dPoeIfPdAliveCfgEntry 1 }
|
|
|
|
dPoeIfPdAliveCfgPdIpType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the IP address type of the target PD."
|
|
::= { dPoeIfPdAliveCfgEntry 2 }
|
|
|
|
dPoeIfPdAliveCfgPdIpAddr OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the IP address of the target PD."
|
|
::= { dPoeIfPdAliveCfgEntry 3 }
|
|
|
|
dPoeIfPdAliveCfgInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (10..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the time interval for system
|
|
issues ping request to detect the target PD.
|
|
The valid range for interval time is 10s to 300s."
|
|
DEFVAL { 30 }
|
|
::= { dPoeIfPdAliveCfgEntry 4 }
|
|
|
|
dPoeIfPdAliveCfgRetry OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..5)
|
|
UNITS "times"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the retry count of ping
|
|
request when PD has no response.
|
|
The valid range for retry count is 0 to 5 times."
|
|
DEFVAL { 2}
|
|
::= { dPoeIfPdAliveCfgEntry 5 }
|
|
|
|
|
|
dPoeIfPdAliveCfgWaitTime OBJECT-TYPE
|
|
SYNTAX Unsigned32 (30..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the waiting time for PD reboot.
|
|
The valid range for waiting time is 30s to 300s."
|
|
DEFVAL { 90 }
|
|
::= { dPoeIfPdAliveCfgEntry 6 }
|
|
|
|
dPoeIfPdAliveCfgAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reset(1),
|
|
notify(2),
|
|
both(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the action when PD doesn't reply the ping request.
|
|
reset- System will reset the PoE port state .
|
|
notify- System will send log and trap to notify the administrator.
|
|
both- System will send log and trap first and reset the PoE port state."
|
|
DEFVAL { both }
|
|
::= { dPoeIfPdAliveCfgEntry 7 }
|
|
|
|
-- *****************************************************************************
|
|
-- MIB Notifications
|
|
-- *****************************************************************************
|
|
dPoeIfPowerDeniedNotification NOTIFICATION-TYPE
|
|
OBJECTS { pethPsePortPowerDeniedCounter }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates if PSE state diagram enters
|
|
the state POWER_DENIED.
|
|
At least 500 msec must elapse between notifications
|
|
being emitted by the same object instance."
|
|
::= { dPoeMIBNotifications 1 }
|
|
|
|
dPoeIfPowerOverLoadNotification NOTIFICATION-TYPE
|
|
OBJECTS { pethPsePortOverLoadCounter }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates if PSE state diagram enters
|
|
the state ERROR_DELAY_OVER.
|
|
At least 500 msec must elapse between notifications
|
|
being emitted by the same object instance."
|
|
::= { dPoeMIBNotifications 2 }
|
|
|
|
dPoeIfPowerShortCircuitNotification NOTIFICATION-TYPE
|
|
OBJECTS { pethPsePortShortCounter }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates if PSE state diagram enters
|
|
the state ERROR_DELAY_SHORT.
|
|
At least 500 msec must elapse between notifications
|
|
being emitted by the same object instance."
|
|
::= { dPoeMIBNotifications 3 }
|
|
|
|
dPoeIfPdAliveFailOccurNotification NOTIFICATION-TYPE
|
|
OBJECTS { pethMainPseGroupIndex,
|
|
pethPsePortIndex,
|
|
dPoeIfPdAliveCfgPdIpType,
|
|
dPoeIfPdAliveCfgPdIpAddr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates if the PD device has
|
|
the stop working or no response problem."
|
|
::= { dPoeMIBNotifications 4 }
|
|
|
|
-- *****************************************************************************
|
|
-- MIB Conformance statements
|
|
-- *****************************************************************************
|
|
dPoeMIBCompliances OBJECT IDENTIFIER ::= { dPoeMIBConformance 1 }
|
|
|
|
dPoeMIBGroups OBJECT IDENTIFIER ::= { dPoeMIBConformance 2 }
|
|
dPoeMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement the
|
|
DLINKSW-POE-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
dPoeGroupCfgGroup,
|
|
dPoeIfCfgGroup,
|
|
dPoeGroupInfoGroup,
|
|
dPoeIfInfoGroup,
|
|
dPoeIfErrorStateNotificationGroup,
|
|
dPoeIfPdAliveCfgGroup
|
|
}
|
|
|
|
::= { dPoeMIBCompliances 1 }
|
|
|
|
dPoeGroupCfgGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dPoeGroupPolicyPreempt,
|
|
dPoeGroupIfLedMode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects to configure or display the group-specific PoE information."
|
|
::= { dPoeMIBGroups 1 }
|
|
|
|
dPoeIfCfgGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dPoeGroupClearIfStatistic,
|
|
dPoeIfState,
|
|
dPoeIfMaxPower,
|
|
dPoeIfTimeRange,
|
|
dPoeIfLegacyPdEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects configure or display the ports information."
|
|
::= { dPoeMIBGroups 2 }
|
|
|
|
dPoeGroupInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dPoeGroupMaxPorts,
|
|
dPoeGroupHWVersion,
|
|
dPoeGroupSWVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects display the groups information."
|
|
::= { dPoeMIBGroups 3 }
|
|
|
|
dPoeIfInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dPoeIfDetectStatus,
|
|
dPoeIfFaultyType,
|
|
dPoeIfVoltage,
|
|
dPoeIfCurrent,
|
|
dPoeIfTemperature,
|
|
dPoeIfPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects display the ports information."
|
|
::= { dPoeMIBGroups 4 }
|
|
|
|
dPoeIfErrorStateNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { dPoeIfPowerDeniedNotification,
|
|
dPoeIfPowerOverLoadNotification,
|
|
dPoeIfPowerShortCircuitNotification
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "A collection of objects provides ports error state notifications."
|
|
::= { dPoeMIBGroups 5 }
|
|
|
|
dPoeIfPdAliveCfgGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dPoeIfPdAliveCfgState,
|
|
dPoeIfPdAliveCfgPdIpType,
|
|
dPoeIfPdAliveCfgPdIpAddr,
|
|
dPoeIfPdAliveCfgInterval,
|
|
dPoeIfPdAliveCfgRetry,
|
|
dPoeIfPdAliveCfgWaitTime,
|
|
dPoeIfPdAliveCfgAction
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects display the PD alive check configuration."
|
|
::= { dPoeMIBGroups 6 }
|
|
|
|
END
|