- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
777 lines
31 KiB
Text
777 lines
31 KiB
Text
-- *****************************************************************
|
|
-- DLINKSW-DDM-MIB.mib : Digital Diagnostics Monitoring (DDM) MIB
|
|
--
|
|
-- Copyright (c) 2013 D-Link Corporation, all rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
DLINKSW-DDM-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
DisplayString,TruthValue,RowStatus
|
|
FROM SNMPv2-TC
|
|
MODULE-IDENTITY,OBJECT-TYPE,Integer32
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
ifIndex, InterfaceIndex
|
|
FROM IF-MIB
|
|
dlinkIndustrialCommon
|
|
FROM DLINK-ID-REC-MIB;
|
|
|
|
dlinkSwDdmMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201302040000Z"
|
|
ORGANIZATION "D-Link Corp."
|
|
CONTACT-INFO
|
|
" D-Link Corporation
|
|
|
|
Postal: No. 289, Sinhu 3rd Rd., Neihu District,
|
|
Taipei City 114, Taiwan, R.O.C
|
|
Tel: +886-2-66000123
|
|
E-mail: tsd@dlink.com.tw
|
|
"
|
|
DESCRIPTION
|
|
"This MIB module defines objects for DDM."
|
|
|
|
REVISION "201302040000Z"
|
|
DESCRIPTION
|
|
"The structure of DDM for the proprietary enterprise."
|
|
|
|
REVISION "201309050000Z"
|
|
DESCRIPTION
|
|
"Modified the object dDdmAlarmTrap and dDdmWarningTrap to
|
|
support to send traps when transceiver monitoring recovers from an
|
|
abnormal warning/alarm situation to normal status."
|
|
::={ dlinkIndustrialCommon 72 }
|
|
|
|
|
|
DlinkThresholdState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the state of a current monitoring value.
|
|
Valid values are:
|
|
|
|
normal(0): the current value is within normal range.
|
|
|
|
higherAlarm(1): the current value is higher than the high alarm threshold.
|
|
|
|
higherWarning(2): the current value is higher than the high warning threshold.
|
|
|
|
lowerWarning(3): the current value is lower than the low warning threshold.
|
|
|
|
lowerAlarm(4): the current value is lower than the low alarm threshold.
|
|
"
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
higherAlarm(1),
|
|
higherWarning(2),
|
|
lowerWarning(3),
|
|
lowerAlarm(4)
|
|
}
|
|
|
|
dDdmMIBNotifications OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 0 }
|
|
dDdmMIBObjects OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 1 }
|
|
dDdmMIBConformance OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 2 }
|
|
|
|
-- --------------------------------------------------------------------------
|
|
dDdmCtrl OBJECT IDENTIFIER ::= { dDdmMIBObjects 1 }
|
|
|
|
dDdmNotifyEnable OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
alarm(0),
|
|
warning(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether a specified notification is enabled or not.
|
|
If a bit corresponding to a notification is set to 1, then
|
|
the specified notification can be generated.
|
|
|
|
alarm(0) - sending an alarm level notification.
|
|
warning(1) - sending an warning level notification.
|
|
"
|
|
::= { dDdmCtrl 1 }
|
|
|
|
|
|
-- --------------------------------------------------------------------------
|
|
dDdmIfCtrl OBJECT IDENTIFIER ::= { dDdmMIBObjects 2 }
|
|
|
|
dDdmIfCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DDdmIfCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains a list of interface-specific DDM configuration."
|
|
::= {dDdmIfCtrl 1}
|
|
|
|
dDdmIfCfgEntry OBJECT-TYPE
|
|
SYNTAX DDdmIfCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry manages DDM state and action on an interface."
|
|
INDEX { ifIndex }
|
|
::= {dDdmIfCfgTable 1}
|
|
|
|
DDdmIfCfgEntry ::=
|
|
SEQUENCE {
|
|
dDdmIfCfgEnabled TruthValue,
|
|
dDdmShutdownLevel INTEGER
|
|
}
|
|
|
|
dDdmIfCfgEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of optical transceiver-monitoring
|
|
function for a SFP port.
|
|
When a SFP with transceiver-monitoring capability is plugged in a
|
|
port but the transceiver-monitoring function of the port is
|
|
disabled, system will not detect the SFP's abnormal status but user
|
|
still can check the current status via dDdmIfInfoTable."
|
|
::= {dDdmIfCfgEntry 1}
|
|
|
|
dDdmShutdownLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
alarm(2),
|
|
warning(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the abnormal level which causes a port
|
|
enter into errDisabled state.
|
|
A value of 'none' indicates the shutdown action is disabled.
|
|
"
|
|
::= {dDdmIfCfgEntry 2}
|
|
|
|
-- --------------------------------------------------------------------------
|
|
dDdmThresholdMgmt OBJECT IDENTIFIER ::= { dDdmMIBObjects 3 }
|
|
|
|
dDdmThresholdCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DDdmThresholdCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains a list of interface-specific threshold configuration for
|
|
DDM."
|
|
::= {dDdmThresholdMgmt 1}
|
|
|
|
dDdmThresholdCfgEntry OBJECT-TYPE
|
|
SYNTAX DDdmThresholdCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in this table conists of one threshold configuration on an interface.
|
|
An entry is created/removed when a configuration is added/deleted.
|
|
"
|
|
INDEX {
|
|
ifIndex,
|
|
dDdmThresholdComponent,
|
|
dDmThresholdAbnormalLevel
|
|
}
|
|
::= { dDdmThresholdCfgTable 1 }
|
|
|
|
DDdmThresholdCfgEntry ::=
|
|
SEQUENCE {
|
|
dDdmThresholdComponent INTEGER,
|
|
dDmThresholdAbnormalLevel INTEGER,
|
|
dDdmThresholdCfgValue Integer32,
|
|
dDdmThresholdCfgRowStatus RowStatus
|
|
}
|
|
|
|
dDdmThresholdComponent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temperature(1),
|
|
voltage(2),
|
|
biasCurrent(3),
|
|
txPowerMw(4),
|
|
txPowerDbm(5),
|
|
rxPowerMw(6),
|
|
rxPowerDbm(7)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the monitoring type.
|
|
Note:
|
|
Either txPowerMw(4) or txPowerDbm(5) can be configured on an interface.
|
|
Either rxPowerMw(6) or rxPowerDbm(7) can be configured on an interface.
|
|
In the above two cases, the existed entry will be deleted when the
|
|
other new entry is created.
|
|
"
|
|
::= {dDdmThresholdCfgEntry 1}
|
|
|
|
dDmThresholdAbnormalLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highAlarm(1),
|
|
highWarning(2),
|
|
lowWarning(3),
|
|
lowAlarm(4)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the threshold type."
|
|
::= { dDdmThresholdCfgEntry 2 }
|
|
|
|
dDdmThresholdCfgValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the configured threshold. The value is
|
|
interpreted within the context of dDdmThresholdComponent and
|
|
dDmThresholdAbnormalLevel in the same row. The unit and valid range
|
|
are as follows:
|
|
Threshold Type Unit Valid Range
|
|
============= ===================== =================
|
|
Temperature milli-degrees Celsius -128,000 ~ 127,996
|
|
voltage centi-Volt 0 ~ 655
|
|
biasCurrent milli-amperes 0 ~ 131
|
|
txPowerMw tenths of a microwatt 0 ~ 65,535
|
|
txPowerDbm ten-thousandths of DBM -400,000 ~ 81,647
|
|
rxPowerMw tenths of a microwatt 0 ~ 65,535
|
|
rxPowerDbm ten-thousandths of DBM -400,000 ~ 81,647
|
|
"
|
|
::= { dDdmThresholdCfgEntry 3 }
|
|
|
|
dDdmThresholdCfgRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this conceptual row."
|
|
::= { dDdmThresholdCfgEntry 4 }
|
|
|
|
-- --------------------------------------------------------------------------
|
|
dDdmInfo OBJECT IDENTIFIER ::= { dDdmMIBObjects 4 }
|
|
|
|
dDdmIfInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DDdmIfInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains a list of information about current operating
|
|
parameters of interfaces. Only the applicable interfaces (i.e.SFP
|
|
module with DDM capability is plugged-in. ) will appear in this table.
|
|
Note:
|
|
1. The threshold may be administratively configured or factory
|
|
preset value defined by vendors. dDdmThresholdCfgTable provides
|
|
the administrative threshold configuration.
|
|
2. It doesn't necessarily means the DDM is enabled on the interface
|
|
when an entry appears in this table. dDdmIfCfgTable provides such
|
|
information."
|
|
::= {dDdmInfo 1}
|
|
|
|
dDdmIfInfoEntry OBJECT-TYPE
|
|
SYNTAX DDdmIfInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry appears in this table contains current operating parameters
|
|
for transceiver monitoring of a port."
|
|
INDEX { ifIndex }
|
|
::= { dDdmIfInfoTable 1}
|
|
|
|
DDdmIfInfoEntry ::=
|
|
SEQUENCE {
|
|
dDdmIfInfoCurrentTemperature Integer32,
|
|
dDdmIfInfoTemperatureState DlinkThresholdState,
|
|
dDdmIfInfoHighAlarmTemperature Integer32,
|
|
dDdmIfInfoHighWarnTemperature Integer32,
|
|
dDdmIfInfoLowWarnTemperature Integer32,
|
|
dDdmIfInfoLowAlarmTemperature Integer32,
|
|
dDdmIfInfoCurrentVoltage Integer32,
|
|
dDdmIfInfoVoltageState DlinkThresholdState,
|
|
dDdmIfInfoHighAlarmVoltage Integer32,
|
|
dDdmIfInfoHighWarnVoltage Integer32,
|
|
dDdmIfInfoLowWarnVoltage Integer32,
|
|
dDdmIfInfoLowAlarmVoltage Integer32,
|
|
dDdmIfInfoCurrentBiasCurrent Integer32,
|
|
dDdmIfInfoBiasCurrentState DlinkThresholdState,
|
|
dDdmIfInfoHighAlarmBiasCurrent Integer32,
|
|
dDdmIfInfoHighWarnBiasCurrent Integer32,
|
|
dDdmIfInfoLowWarnBiasCurrent Integer32,
|
|
dDdmIfInfoLowAlarmBiasCurrent Integer32,
|
|
dDdmIfInfoCurrentTxPower Integer32,
|
|
dDdmIfInfoTxPowerState DlinkThresholdState,
|
|
dDdmIfInfoHighAlarmTxPower Integer32,
|
|
dDdmIfInfoHighWarnTxPower Integer32,
|
|
dDdmIfInfoLowWarnTxPower Integer32,
|
|
dDdmIfInfoLowAlarmTxPower Integer32,
|
|
dDdmIfInfoCurrentRxPower Integer32,
|
|
dDdmIfInfoRxPowerState DlinkThresholdState,
|
|
dDdmIfInfoHighAlarmRxPower Integer32,
|
|
dDdmIfInfoHighWarnRxPower Integer32,
|
|
dDdmIfInfoLowWarnRxPower Integer32,
|
|
dDdmIfInfoLowAlarmRxPower Integer32
|
|
}
|
|
|
|
dDdmIfInfoCurrentTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milli-degrees Celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the current temperature in unit of
|
|
'milli-degrees Celsius' on the interface."
|
|
::= { dDdmIfInfoEntry 1 }
|
|
|
|
dDdmIfInfoTemperatureState OBJECT-TYPE
|
|
SYNTAX DlinkThresholdState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the state of current temperature."
|
|
::= { dDdmIfInfoEntry 2 }
|
|
|
|
dDdmIfInfoHighAlarmTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milli-degrees Celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the high alarm threshold, when the operating
|
|
temperature rises above this value, it indicates an alarm status.
|
|
The value is in unit of 'milli-degrees Celsius'."
|
|
::= { dDdmIfInfoEntry 3 }
|
|
|
|
|
|
dDdmIfInfoHighWarnTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milli-degrees Celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the high warning threshold, when the operating
|
|
temperature rises above this value, it indicates a warning status.
|
|
The value is in unit of 'milli-degrees Celsius'."
|
|
::= { dDdmIfInfoEntry 4 }
|
|
|
|
dDdmIfInfoLowWarnTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milli-degrees Celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the low warning threshold, when the operating
|
|
temperature falls below this value, it indicates a warning status.
|
|
The value is in unit of 'milli-degrees Celsius'."
|
|
::= { dDdmIfInfoEntry 5 }
|
|
|
|
dDdmIfInfoLowAlarmTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milli-degrees Celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the low alarm threshold, when the operating
|
|
temperature falls below this value, it indicates an alarm status.
|
|
The value is in unit of 'milli-degrees Celsius'."
|
|
::= { dDdmIfInfoEntry 6 }
|
|
|
|
dDdmIfInfoCurrentVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "centi-Volt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the current voltage in unit of
|
|
'centi-Volt' on the interface."
|
|
::= { dDdmIfInfoEntry 7 }
|
|
|
|
dDdmIfInfoVoltageState OBJECT-TYPE
|
|
SYNTAX DlinkThresholdState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the state of current voltage."
|
|
::= { dDdmIfInfoEntry 8 }
|
|
|
|
dDdmIfInfoHighAlarmVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "centi-Volt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the high alarm threshold, when the operating
|
|
voltage rises above this value, it indicates an alarm status.
|
|
The value is in unit of 'centi-Volt'."
|
|
::= { dDdmIfInfoEntry 9 }
|
|
|
|
dDdmIfInfoHighWarnVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "centi-Volt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the high warning threshold, when the operating
|
|
voltage rises above this value, it indicates a warning status.
|
|
The value is in unit of 'centi-Volt'."
|
|
::= { dDdmIfInfoEntry 10 }
|
|
|
|
dDdmIfInfoLowWarnVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "centi-Volt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the low warning threshold, when the operating
|
|
voltage falls below this value, it indicates a warning status.
|
|
The value is in unit of 'centi-Volt'."
|
|
::= { dDdmIfInfoEntry 11 }
|
|
|
|
dDdmIfInfoLowAlarmVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "centi-Volt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the low alarm threshold, when the operating
|
|
voltage falls below this value, it indicates an alarm status.
|
|
The value is in unit of 'centi-Volt'."
|
|
::= { dDdmIfInfoEntry 12 }
|
|
|
|
dDdmIfInfoCurrentBiasCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milli-amperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the current bias current in unit of
|
|
'milli-amperes' on the interface."
|
|
::= { dDdmIfInfoEntry 13 }
|
|
|
|
dDdmIfInfoBiasCurrentState OBJECT-TYPE
|
|
SYNTAX DlinkThresholdState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the state of current BiasCurrent."
|
|
::= { dDdmIfInfoEntry 14 }
|
|
|
|
dDdmIfInfoHighAlarmBiasCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milli-amperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the high alarm threshold, when the operating
|
|
bias current rises above this value, it indicates an alarm status.
|
|
The value is in unit of 'milli-amperes'."
|
|
::= { dDdmIfInfoEntry 15 }
|
|
|
|
dDdmIfInfoHighWarnBiasCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milli-amperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the high warning threshold, when the operating
|
|
bias current rises above this value, it indicates a warning status.
|
|
The value is in unit of 'milli-amperes'."
|
|
::= { dDdmIfInfoEntry 16 }
|
|
|
|
dDdmIfInfoLowWarnBiasCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milli-amperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the low warning threshold, when the operating
|
|
bias current falls below this value, it indicates a warning status.
|
|
The value is in unit of 'milli-amperes'."
|
|
::= { dDdmIfInfoEntry 17 }
|
|
|
|
dDdmIfInfoLowAlarmBiasCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milli-amperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the low alarm threshold, when the operating
|
|
bias current falls below this value, it indicates an alarm status.
|
|
The value is in unit of 'milli-amperes'."
|
|
::= { dDdmIfInfoEntry 18 }
|
|
|
|
dDdmIfInfoCurrentTxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "tenths of a microwatt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the current output power in unit of
|
|
'tenths of a microwatt' on the interface."
|
|
::= { dDdmIfInfoEntry 19 }
|
|
|
|
dDdmIfInfoTxPowerState OBJECT-TYPE
|
|
SYNTAX DlinkThresholdState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the state of current output power."
|
|
::= { dDdmIfInfoEntry 20 }
|
|
|
|
dDdmIfInfoHighAlarmTxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "tenths of a microwatt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the high alarm threshold, when the operating
|
|
output power rises above this value, it indicates an alarm status.
|
|
The value is in unit of 'tenths of a microwatt'."
|
|
::= { dDdmIfInfoEntry 21 }
|
|
|
|
dDdmIfInfoHighWarnTxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "tenths of a microwatt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the high warning threshold, when the operating
|
|
output power rises above this value, it indicates a warning status.
|
|
The value is in unit of 'tenths of a microwatt'."
|
|
::= { dDdmIfInfoEntry 22 }
|
|
|
|
dDdmIfInfoLowWarnTxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "tenths of a microwatt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the low warning threshold, when the operating
|
|
output power falls below this value, it indicates a warning status.
|
|
The value is in unit of 'tenths of a microwatt'."
|
|
::= { dDdmIfInfoEntry 23 }
|
|
|
|
dDdmIfInfoLowAlarmTxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "tenths of a microwatt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the low alarm threshold, when the operating
|
|
output power falls below this value, it indicates an alarm status.
|
|
The value is in unit of 'tenths of a microwatt'."
|
|
::= { dDdmIfInfoEntry 24 }
|
|
|
|
dDdmIfInfoCurrentRxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "tenths of a microwatt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the current input power in unit of
|
|
'tenths of a microwatt' on the interface."
|
|
::= { dDdmIfInfoEntry 25 }
|
|
|
|
dDdmIfInfoRxPowerState OBJECT-TYPE
|
|
SYNTAX DlinkThresholdState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the state of current input power."
|
|
::= { dDdmIfInfoEntry 26 }
|
|
|
|
dDdmIfInfoHighAlarmRxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "tenths of a microwatt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the high alarm threshold, when the operating
|
|
input power rises above this value, it indicates an alarm status.
|
|
The value is in unit of 'tenths of a microwatt'."
|
|
::= { dDdmIfInfoEntry 27 }
|
|
|
|
dDdmIfInfoHighWarnRxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "tenths of a microwatt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the high warning threshold, when the operating
|
|
input power rises above this value, it indicates a warning status.
|
|
The value is in unit of 'tenths of a microwatt'."
|
|
::= { dDdmIfInfoEntry 28 }
|
|
|
|
dDdmIfInfoLowWarnRxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "tenths of a microwatt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the low warning threshold, when the operating
|
|
input power falls below this value, it indicates a warning status.
|
|
The value is in unit of 'tenths of a microwatt'."
|
|
::= { dDdmIfInfoEntry 29 }
|
|
|
|
dDdmIfInfoLowAlarmRxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "tenths of a microwatt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the low alarm threshold, when the operating
|
|
input power falls below this value, it indicates an alarm status.
|
|
The value is in unit of 'tenths of a microwatt'."
|
|
::= { dDdmIfInfoEntry 30 }
|
|
|
|
-- --------------------------------------------------------------------------
|
|
dDdmNotifyInfo OBJECT IDENTIFIER ::= { dDdmMIBObjects 5 }
|
|
|
|
dDdmNotifyInfoIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate
|
|
the ifIndex on which the monitoring value rises above or falls below
|
|
the corresponding threshold."
|
|
::= { dDdmNotifyInfo 1 }
|
|
|
|
dDdmNotifyInfoComponent OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
temperature(1),
|
|
voltage(2),
|
|
biasCurrent(3),
|
|
txPowerMw(4),
|
|
rxPowerMw(5)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate
|
|
the abnormal component."
|
|
::= { dDdmNotifyInfo 2 }
|
|
|
|
dDdmNotifyInfoAbnormalLevel OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
high(1),
|
|
low(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate
|
|
the abnormal level."
|
|
::= { dDdmNotifyInfo 3 }
|
|
|
|
dDdmNotifyInfoThresholdExceedOrRecover OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
exceed(1),
|
|
recover(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate the
|
|
GBIC is exceeding its threshold or recover to
|
|
normal status."
|
|
::= {dDdmNotifyInfo 4}
|
|
|
|
|
|
-- --------------------------------------------------------------------------
|
|
|
|
dDdmAlarmTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
dDdmNotifyInfoIfIndex,
|
|
dDdmNotifyInfoComponent,
|
|
dDdmNotifyInfoAbnormalLevel,
|
|
dDdmNotifyInfoThresholdExceedOrRecover
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent when dDdmNotifyEnable is 'true' and an abnormal
|
|
alarm situation occurs or recovers from an abnormal alarm situation
|
|
to normal status."
|
|
::= { dDdmMIBNotifications 1 }
|
|
|
|
dDdmWarningTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
dDdmNotifyInfoIfIndex,
|
|
dDdmNotifyInfoComponent,
|
|
dDdmNotifyInfoAbnormalLevel,
|
|
dDdmNotifyInfoThresholdExceedOrRecover
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent when dDdmNotifyEnable is 'true' and an abnormal
|
|
warning situation occurs or recovers from an abnormal warning
|
|
situation to normal status."
|
|
::= { dDdmMIBNotifications 2 }
|
|
|
|
-- ***************************************************************************
|
|
-- Conformance
|
|
-- ***************************************************************************
|
|
dDdmCompliances OBJECT IDENTIFIER ::= { dDdmMIBConformance 1 }
|
|
|
|
dDdmCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement the
|
|
DLINKSW-DDM-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
dDdmInfoGroup,
|
|
dDdmCfgGroup,
|
|
dDdmNotifyGroup
|
|
}
|
|
::= { dDdmCompliances 1 }
|
|
|
|
dDdmGroups OBJECT IDENTIFIER ::= { dDdmMIBConformance 2 }
|
|
|
|
dDdmInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dDdmIfInfoCurrentTemperature, dDdmIfInfoTemperatureState,
|
|
dDdmIfInfoHighAlarmTemperature, dDdmIfInfoHighWarnTemperature,
|
|
dDdmIfInfoLowWarnTemperature, dDdmIfInfoLowAlarmTemperature,
|
|
dDdmIfInfoCurrentVoltage, dDdmIfInfoVoltageState,
|
|
dDdmIfInfoHighAlarmVoltage, dDdmIfInfoHighWarnVoltage,
|
|
dDdmIfInfoLowWarnVoltage, dDdmIfInfoLowAlarmVoltage,
|
|
dDdmIfInfoCurrentBiasCurrent, dDdmIfInfoBiasCurrentState,
|
|
dDdmIfInfoHighAlarmBiasCurrent, dDdmIfInfoHighWarnBiasCurrent,
|
|
dDdmIfInfoLowWarnBiasCurrent, dDdmIfInfoLowAlarmBiasCurrent,
|
|
dDdmIfInfoCurrentTxPower, dDdmIfInfoTxPowerState,
|
|
dDdmIfInfoHighAlarmTxPower, dDdmIfInfoHighWarnTxPower,
|
|
dDdmIfInfoLowWarnTxPower, dDdmIfInfoLowAlarmTxPower,
|
|
dDdmIfInfoCurrentRxPower, dDdmIfInfoRxPowerState,
|
|
dDdmIfInfoHighAlarmRxPower, dDdmIfInfoHighWarnRxPower,
|
|
dDdmIfInfoLowWarnRxPower, dDdmIfInfoLowAlarmRxPower,
|
|
dDdmNotifyInfoIfIndex, dDdmNotifyInfoComponent,
|
|
dDdmNotifyInfoAbnormalLevel,
|
|
dDdmNotifyInfoThresholdExceedOrRecover
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects provides DDM operating information."
|
|
::= { dDdmGroups 1 }
|
|
|
|
dDdmCfgGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dDdmNotifyEnable,
|
|
dDdmIfCfgEnabled, dDdmShutdownLevel,
|
|
dDdmThresholdCfgValue, dDdmThresholdCfgRowStatus
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects provides DDM configuration."
|
|
::= { dDdmGroups 2 }
|
|
|
|
dDdmNotifyGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
dDdmAlarmTrap,
|
|
dDdmWarningTrap
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of notifications used for DDM."
|
|
::= { dDdmGroups 3 }
|
|
|
|
END
|