- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
640 lines
20 KiB
Text
640 lines
20 KiB
Text
-- =================================================================
|
|
-- Copyright (c) 2004-2021 New H3C Tech. Co., Ltd. All rights reserved
|
|
--
|
|
-- Description: stack mib
|
|
-- Reference: STACK-MIB
|
|
-- Version: V1.5
|
|
-- History:
|
|
-- V1.0 Created by ranbin
|
|
-- Initial version 2008-04-30
|
|
-- V1.1 2012-02-24 Modified by zhengwei
|
|
-- Changed the range of link delay to 0 to 30000 ms
|
|
-- V1.2 2013-08-16 Updated by wangpengju
|
|
-- Added node hh3cStackPortForwardingPath to hh3cStackPortInfoTable
|
|
-- 2013-10-23 Updated by zhengwei
|
|
-- Added notification nodes because MAD group work status changed:
|
|
-- hh3cStackMadBfdChangeNormal
|
|
-- hh3cStackMadBfdChangeFailure
|
|
-- hh3cStackMadLacpChangeNormal
|
|
-- hh3cStackMadLacpChangeFailure
|
|
-- V1.3 2014-08-11 Updated by SongHao
|
|
-- Added hh3cStackDomainId
|
|
-- 2014-11-20 Updated by songhao
|
|
-- Added hh3cStackPortConfigActivate in hh3cStackGlobalConfig.
|
|
-- hh3cStackLinkDelayInterval was changed to in the range of 0 to 2147483647 ms
|
|
-- V1.4 2020-03-03 Updated by zhangwenbo
|
|
-- Added notification node hh3cStackPhysicalIntfLinkUp
|
|
-- Added notification node hh3cStackPhysicalIntfLinkDown
|
|
-- Added hh3cStackPhysicalIntfName
|
|
-- V1.5 2021-03-17 Updated by meishenhe
|
|
-- Added notification node hh3cStackPhysicalIntfRxTimeout
|
|
-- =================================================================
|
|
HH3C-STACK-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
hh3cCommon
|
|
FROM HH3C-OID-MIB
|
|
entPhysicalIndex
|
|
FROM ENTITY-MIB
|
|
ifIndex, ifDescr
|
|
FROM IF-MIB
|
|
Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Unsigned32
|
|
FROM SNMPv2-SMI;
|
|
|
|
hh3cStack MODULE-IDENTITY
|
|
LAST-UPDATED "202103250943Z"
|
|
ORGANIZATION
|
|
"New H3C Technologies Co., Ltd."
|
|
CONTACT-INFO
|
|
"Platform Team New H3C Technologies Co., Ltd.
|
|
Hai-Dian District Beijing P.R. China
|
|
Http://www.h3c.com
|
|
Zip:100085"
|
|
DESCRIPTION
|
|
"This MIB is used to manage STM (Stack Topology Management)
|
|
information for IRF (Intelligent Resilient Framework) device.
|
|
This MIB is applicable to IRF-capable products. Some objects in
|
|
this MIB may be used only for some specific products, so users should
|
|
refer to the related documents to acquire more detailed information."
|
|
REVISION "202103250943Z"
|
|
DESCRIPTION
|
|
"Added notification node hh3cStackPhysicalIntfRxTimeout."
|
|
REVISION "201411200850Z"
|
|
DESCRIPTION
|
|
"Added hh3cStackPortConfigActivate in hh3cStackGlobalConfig.
|
|
hh3cStackLinkDelayInterval was changed to in the range of 0 to
|
|
2147483647 ms."
|
|
REVISION "201408110641Z"
|
|
DESCRIPTION
|
|
"Added hh3cStackDomainId."
|
|
REVISION "201310230000Z"
|
|
DESCRIPTION
|
|
"Added notification nodes because MAD group work status changed:
|
|
hh3cStackMadBfdChangeNormal
|
|
hh3cStackMadBfdChangeFailure
|
|
hh3cStackMadLacpChangeNormal
|
|
hh3cStackMadLacpChangeFailure"
|
|
REVISION "201308160000Z"
|
|
DESCRIPTION
|
|
"Added node hh3cStackPortForwardingPath to hh3cStackPortInfoTable."
|
|
REVISION "201202240000Z"
|
|
DESCRIPTION
|
|
"Changed the range of link delay to 0 to 30000 ms."
|
|
REVISION "200804301650Z" -- 30th April, 2007 at 16:50 GMT
|
|
DESCRIPTION
|
|
"The initial revision of this MIB module."
|
|
::= { hh3cCommon 91 }
|
|
|
|
|
|
-- Scalar MIB objects, which are considered as global variables
|
|
-- Global Level Configuration
|
|
|
|
hh3cStackGlobalConfig OBJECT IDENTIFIER ::= { hh3cStack 1 }
|
|
|
|
hh3cStackMaxMember OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of members in a stack."
|
|
::= { hh3cStackGlobalConfig 1 }
|
|
|
|
hh3cStackMemberNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of members currently in a stack."
|
|
::= { hh3cStackGlobalConfig 2 }
|
|
|
|
hh3cStackMaxConfigPriority OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest priority that can be configured for a member in a stack."
|
|
::= { hh3cStackGlobalConfig 3 }
|
|
|
|
hh3cStackAutoUpdate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The function for automatically updating the image from the master to
|
|
a device that is attempting to join the stack.
|
|
When a new device tries to join a stack, STM verifies the image
|
|
consistency between the joining device and the master.
|
|
If the joining device uses a different image version than the master,
|
|
the function updates the joining device with the image of the master.
|
|
When this function is disabled, the new device can't join the stack
|
|
if it uses a different software version than the master.
|
|
|
|
disabled: disable auto update function
|
|
enabled: enable auto update function"
|
|
::= { hh3cStackGlobalConfig 4 }
|
|
|
|
hh3cStackMacPersistence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notPersist(1),
|
|
persistForSixMin(2),
|
|
persistForever(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The mode of bridge MAC address persistence. When a stack starts,
|
|
the bridge MAC address of the master is used as that of the stack.
|
|
When the master leaves the stack, the bridge MAC address of the
|
|
stack changes depending on the mode of bridge MAC address persistence.
|
|
|
|
notPersist: The bridge MAC address of the new master is used
|
|
as that of the stack immediately.
|
|
persistForSixMin: The original bridge MAC address will be reserved for six
|
|
minutes. In this period, if the master that has left rejoins the stack,
|
|
the bridge MAC address of the stack will not change.
|
|
If the old master doesn't rejoin the stack within this period, the
|
|
bridge MAC address of the new master will be used as that of the stack.
|
|
persistForever: Whether the master leaves or not, the bridge MAC address
|
|
of the stack will never change."
|
|
::= { hh3cStackGlobalConfig 5 }
|
|
|
|
hh3cStackLinkDelayInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
UNITS "millisecond"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Delay for stack ports to report a link down event. If the link comes up
|
|
before the delay timer expires, the stack port will not report the link
|
|
down event. If the link is not recovered before the delay timer expires,
|
|
the stack port will report the change. If the delay is set to 0,
|
|
the stack ports will report a link down event without delay.
|
|
|
|
0: no delay
|
|
other value(ms): delay time"
|
|
::= { hh3cStackGlobalConfig 6 }
|
|
|
|
hh3cStackTopology OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
chainConn(1),
|
|
ringConn(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Stack topology.
|
|
|
|
chainConn: daisy-chain connection
|
|
ringConn: ring connection"
|
|
::= { hh3cStackGlobalConfig 7 }
|
|
|
|
hh3cStackDomainId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..4294967295)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Domain ID of the IRF fabric that is used to uniquely identify an IRF fabric.
|
|
Domain IDs prevent IRF fabrics from interfering with one another."
|
|
::= { hh3cStackGlobalConfig 8 }
|
|
|
|
hh3cStackPortConfigActivate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(1),
|
|
set(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"After connecting the physical interfaces between two devices and
|
|
binding them to the correct IRF ports, you must
|
|
activate the settings on the IRF ports. This operation merges the two
|
|
devices into one IRF fabric. The system activates the IRF port
|
|
settings automatically in the following situations:
|
|
1. The configuration file that the device starts with contains
|
|
IRF port bindings.
|
|
2. You are binding physical interfaces to an IRF port after an IRF fabric
|
|
is formed.
|
|
|
|
none: If the user sets this object to none, this object will return
|
|
a success without performing any operation.
|
|
|
|
set: Activates the settings on the IRF ports.
|
|
After the settings is activated, this object will return to
|
|
none at the next reading."
|
|
DEFVAL { none }
|
|
::= { hh3cStackGlobalConfig 9 }
|
|
|
|
-- Device Level Configuration
|
|
hh3cStackDeviceConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cStackDeviceConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to manage device information in a stack."
|
|
::= { hh3cStack 2 }
|
|
|
|
hh3cStackDeviceConfigEntry OBJECT-TYPE
|
|
SYNTAX Hh3cStackDeviceConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to manage device information in a stack."
|
|
INDEX
|
|
{
|
|
entPhysicalIndex
|
|
}
|
|
::= { hh3cStackDeviceConfigTable 1 }
|
|
|
|
Hh3cStackDeviceConfigEntry ::= SEQUENCE
|
|
{
|
|
hh3cStackMemberID Integer32,
|
|
hh3cStackConfigMemberID Integer32,
|
|
hh3cStackPriority Integer32,
|
|
hh3cStackPortNum Integer32,
|
|
hh3cStackPortMaxNum Integer32
|
|
}
|
|
|
|
hh3cStackMemberID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The member ID of the device in a stack."
|
|
::= { hh3cStackDeviceConfigEntry 1 }
|
|
|
|
hh3cStackConfigMemberID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured member ID of the device. The valid value ranges from
|
|
1 to the value in hh3cStackMaxMember. The configured member ID will
|
|
take effect at a reboot if it is unique within the stack."
|
|
::= { hh3cStackDeviceConfigEntry 2 }
|
|
|
|
hh3cStackPriority OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority of a device in the stack. The valid value ranges from
|
|
1 to the value in hh3cStackMaxConfigPriority."
|
|
::= { hh3cStackDeviceConfigEntry 3 }
|
|
|
|
hh3cStackPortNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of stack ports enabled on a device."
|
|
::= { hh3cStackDeviceConfigEntry 4 }
|
|
|
|
hh3cStackPortMaxNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of stack ports on a device."
|
|
::= { hh3cStackDeviceConfigEntry 5 }
|
|
|
|
|
|
-- Board Level Configuration
|
|
hh3cStackBoardConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cStackBoardConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to manage MPU information for a stack."
|
|
::= { hh3cStack 3 }
|
|
|
|
hh3cStackBoardConfigEntry OBJECT-TYPE
|
|
SYNTAX Hh3cStackBoardConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to manage MPU information for a stack."
|
|
INDEX
|
|
{
|
|
entPhysicalIndex
|
|
}
|
|
::= { hh3cStackBoardConfigTable 1 }
|
|
|
|
Hh3cStackBoardConfigEntry ::= SEQUENCE
|
|
{
|
|
hh3cStackBoardRole INTEGER,
|
|
hh3cStackBoardBelongtoMember Integer32
|
|
}
|
|
|
|
hh3cStackBoardRole OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
slave(1),
|
|
master(2),
|
|
loading(3),
|
|
other(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The role of the MPU in a stack.
|
|
|
|
slave: Standby MPU
|
|
master: Master MPU
|
|
loading: Standby MPU is loading the software image from the master.
|
|
other: other"
|
|
::= { hh3cStackBoardConfigEntry 1 }
|
|
|
|
hh3cStackBoardBelongtoMember OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Member ID of the device that holds the current board."
|
|
::= { hh3cStackBoardConfigEntry 2 }
|
|
|
|
|
|
-- stack port Information
|
|
hh3cStackPortInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cStackPortInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to manage stack port information
|
|
for IRF stacked devices."
|
|
::= { hh3cStack 4 }
|
|
|
|
hh3cStackPortInfoEntry OBJECT-TYPE
|
|
SYNTAX Hh3cStackPortInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to manage stack port information
|
|
for IRF stacked devices."
|
|
INDEX
|
|
{
|
|
hh3cStackMemberID,
|
|
hh3cStackPortIndex
|
|
}
|
|
::= { hh3cStackPortInfoTable 1 }
|
|
|
|
Hh3cStackPortInfoEntry ::= SEQUENCE
|
|
{
|
|
hh3cStackPortIndex Integer32,
|
|
hh3cStackPortEnable INTEGER,
|
|
hh3cStackPortStatus INTEGER,
|
|
hh3cStackNeighbor Integer32,
|
|
hh3cStackPortForwardingPath OCTET STRING
|
|
}
|
|
|
|
hh3cStackPortIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of a stack port of the device."
|
|
::= { hh3cStackPortInfoEntry 1 }
|
|
|
|
hh3cStackPortEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of a stack port of the device. If no physical
|
|
interfaces are added to the stack port, its status is disabled.
|
|
If the stack port has physical interfaces, its status is enabled.
|
|
|
|
disabled: The stack port is disabled.
|
|
enabled: The stack port is enabled."
|
|
::= { hh3cStackPortInfoEntry 2 }
|
|
|
|
hh3cStackPortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2),
|
|
silent(3),
|
|
disabled(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The link status of a stack port on the device.
|
|
|
|
up: A physical link is present on the stack port.
|
|
down: No physical link is present on the stack port.
|
|
silent: The link state of the stack port is up,
|
|
but the port can't transmit or receive traffic.
|
|
disabled: The stack port doesn't contain physical links."
|
|
::= { hh3cStackPortInfoEntry 3 }
|
|
|
|
hh3cStackNeighbor OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The member ID of the stack port's neighbor. 0 means no
|
|
neighbor exists."
|
|
::= { hh3cStackPortInfoEntry 4 }
|
|
|
|
hh3cStackPortForwardingPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..511))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of egress member IDs on a stack port.
|
|
Each member device uses the egress member ID lists to choose the outgoing
|
|
stack port for known unicast frames to be sent out of other member devices.
|
|
The egress member ID lists are comma separated.
|
|
A zero-length string means no egress members exist.
|
|
|
|
For example:
|
|
In a ring stack of 1-2-3-4-5-7-1,
|
|
if hh3cStackPortForwardingPath.1.1 returns '7,5,4',
|
|
IRF-port 1/1 will be the outgoing port for frames to reach members 7, 5,
|
|
and 4 from member 1."
|
|
::= { hh3cStackPortInfoEntry 5 }
|
|
|
|
-- Physical interface Information
|
|
hh3cStackPhyPortInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cStackPhyPortInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to manage information about physical
|
|
interfaces that can be used for IRF stacking."
|
|
::= { hh3cStack 5 }
|
|
|
|
hh3cStackPhyPortInfoEntry OBJECT-TYPE
|
|
SYNTAX Hh3cStackPhyPortInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to manage information about physical
|
|
interfaces that can be used for IRF stacking."
|
|
INDEX
|
|
{
|
|
entPhysicalIndex
|
|
}
|
|
::= { hh3cStackPhyPortInfoTable 1 }
|
|
|
|
Hh3cStackPhyPortInfoEntry ::= SEQUENCE
|
|
{
|
|
hh3cStackBelongtoPort Integer32
|
|
}
|
|
|
|
hh3cStackBelongtoPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the stack port to which the physical interface is added.
|
|
0 means the physical interface is not added to any stack port.
|
|
The value will take effect when IRF is enabled on the device."
|
|
::= { hh3cStackPhyPortInfoEntry 1 }
|
|
|
|
--
|
|
-- Notification definitions
|
|
--
|
|
-- =================================================================
|
|
-- Traps are defined below.
|
|
hh3cStackTrap OBJECT IDENTIFIER ::= { hh3cStack 6 }
|
|
|
|
hh3cStackTrapOjbects OBJECT IDENTIFIER ::= { hh3cStackTrap 0 }
|
|
-- All trap definitions should be placed under this object.
|
|
|
|
hh3cStackPortLinkStatusChange NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hh3cStackMemberID,
|
|
hh3cStackPortIndex,
|
|
hh3cStackPortStatus
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hh3cStackPortLinkStatusChange trap indicates that the link status
|
|
of the stack port has changed."
|
|
::= { hh3cStackTrapOjbects 1 }
|
|
|
|
hh3cStackTopologyChange NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hh3cStackTopology
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hh3cStackTopologyChange trap indicates that the topology type of
|
|
the IRF stack has changed."
|
|
::= { hh3cStackTrapOjbects 2 }
|
|
|
|
hh3cStackMadBfdChangeNormal NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
ifIndex,
|
|
ifDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hh3cStackMadBfdChangeNormal trap indicates that the BFD MAD function
|
|
changed to the normal state."
|
|
::= { hh3cStackTrapOjbects 3 }
|
|
|
|
hh3cStackMadBfdChangeFailure NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
ifIndex,
|
|
ifDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hh3cStackMadBfdChangeFailure trap indicates that the BFD MAD function
|
|
changed to the failure state."
|
|
::= { hh3cStackTrapOjbects 4 }
|
|
|
|
hh3cStackMadLacpChangeNormal NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
ifIndex,
|
|
ifDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hh3cStackMadLacpChangeNormal trap indicates that the LACP MAD function
|
|
changed to the normal state."
|
|
::= { hh3cStackTrapOjbects 5 }
|
|
|
|
hh3cStackMadLacpChangeFailure NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
ifIndex,
|
|
ifDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hh3cStackMadLacpChangeFailure trap indicates that the LACP MAD function
|
|
changed to the failure state."
|
|
::= { hh3cStackTrapOjbects 6 }
|
|
|
|
hh3cStackPhysicalIntfLinkUp NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hh3cStackMemberID,
|
|
hh3cStackPortIndex,
|
|
hh3cStackPhysicalIntfName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hh3cStackPhysicalIntfLinkUp trap indicates that the status
|
|
of the stack physical interface has changed to the up state."
|
|
::= { hh3cStackTrapOjbects 7 }
|
|
|
|
hh3cStackPhysicalIntfLinkDown NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hh3cStackMemberID,
|
|
hh3cStackPortIndex,
|
|
hh3cStackPhysicalIntfName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hh3cStackPhysicalIntfLinkDown trap indicates that the status
|
|
of the stack physical interface has changed to the down state."
|
|
::= { hh3cStackTrapOjbects 8 }
|
|
|
|
hh3cStackPhysicalIntfRxTimeout NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hh3cStackMemberID,
|
|
hh3cStackPortIndex,
|
|
hh3cStackPhysicalIntfName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hh3cStackPhysicalIntfRxTimeout trap indicates that the timer for the stack
|
|
physical interface to receive packets has timed out."
|
|
::= { hh3cStackTrapOjbects 9 }
|
|
|
|
hh3cStackTrapObjectDefinitions OBJECT IDENTIFIER ::= { hh3cStackTrap 1 }
|
|
-- All objects used for TRAP only are defined here.
|
|
|
|
hh3cStackPhysicalIntfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..255))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The textual name of the stack physical interface."
|
|
::= { hh3cStackTrapObjectDefinitions 1 }
|
|
|
|
END
|
|
|