- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
1123 lines
29 KiB
Text
1123 lines
29 KiB
Text
-- =================================================================
|
|
-- Copyright (c) 2004-2016 New H3C Tech. Co., Ltd. All rights reserved.
|
|
--
|
|
-- Description:
|
|
-- Reference:
|
|
-- Version: V1.7
|
|
-- History:
|
|
-- V1.0 created by liujingya.
|
|
-- Initial version of the MIB
|
|
-- V1.1 2008-1-29 Adjusted the structure of some tables by liujingya.
|
|
-- V1.2 2008-5-19 Added hh3cHPEOCCltAutoUpgrade, hh3cHPEOCCnuAnonymStatus and
|
|
-- hh3cHPEOCBitPerSymbolTable, modified description of hh3cHPEOCCnuBcastControl
|
|
-- by liujingya.
|
|
-- V1.3 2009-2-13 Added hh3cHPEOCOnLineCnuNumber, hh3cHPEOCCpuMacAddress,
|
|
-- hh3cHPEOCOffLineCnuNumber, hh3cHPEOCDownLoadCNUFWResult,
|
|
-- hh3cHPEOCCltAutoUpgradeType, hh3cHPEOCServerAddress, hh3cHPEOCServerUser,
|
|
-- hh3cHPEOCServerPassword and hh3cHPEOCCnuMacLimit by liujingya.
|
|
-- V1.4 2011-12-28 Added hh3cHPEOCCltLinkState by gaoguangping.
|
|
-- 2012-03-14 Added hh3cHPEOCCltLoopbackDetect by gaoguangping.
|
|
-- V1.5 2013-08-20 Added hh3cHPEOCTemplate,hh3cHPEOCCnuAccess by xujun
|
|
-- 2013-09-16 Added hh3cHPEOCTemplateEnable by xujun
|
|
-- V1.6 2015-04-30 Bug fixed by songhao
|
|
-- V1.7 2016-09-02 Bug fixed by gaoguangping
|
|
-- =================================================================
|
|
HH3C-HPEOC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
hh3cCommon
|
|
FROM HH3C-OID-MIB
|
|
ifIndex
|
|
FROM IF-MIB
|
|
Integer32, Unsigned32, Counter64, OBJECT-TYPE, MODULE-IDENTITY,
|
|
IpAddress
|
|
FROM SNMPv2-SMI
|
|
DisplayString, TruthValue, MacAddress, RowStatus
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
hh3cHPEOC MODULE-IDENTITY
|
|
LAST-UPDATED "200708281008Z"
|
|
ORGANIZATION
|
|
"New H3C Tech. Co., Ltd."
|
|
CONTACT-INFO
|
|
"SMB EOC Team New H3C Technologies Co., Ltd.
|
|
Shang-Di Information Industry Base,
|
|
Hai-Dian District Beijing P.R. China
|
|
http://www.h3c.com
|
|
Zip:310053."
|
|
DESCRIPTION
|
|
"
|
|
The objects in this MIB module are used to manage and
|
|
display current configuration of Ethernet Over Cable
|
|
Network (EOC) which based on HomePlug(HP) AV Specification.
|
|
"
|
|
::= { hh3cCommon 84 }
|
|
|
|
--
|
|
-- hh3cHPEOCSystem
|
|
--
|
|
hh3cHPEOCSystem OBJECT IDENTIFIER ::= { hh3cHPEOC 1 }
|
|
|
|
hh3cHPEOCCltVlanType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ieee8021q(1),
|
|
portbased(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Control EOC CLT's VLAN type,
|
|
ieee8021q : 802.1q VLAN mode,
|
|
portbased : portbased VLAN mode.
|
|
"
|
|
::= { hh3cHPEOCSystem 1 }
|
|
|
|
--
|
|
-- hh3cHPEOCCltVlanManTable
|
|
--
|
|
hh3cHPEOCCltVlanManTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCCltVlanManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table implements the management of CLT(Coax Line Terminal)
|
|
VLAN.
|
|
"
|
|
::= { hh3cHPEOCSystem 2 }
|
|
|
|
hh3cHPEOCCltVlanManEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCCltVlanManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCCltVlanManTable.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hh3cHPEOCCltVlanManTable 1 }
|
|
|
|
Hh3cHPEOCCltVlanManEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCCltEthPortType INTEGER
|
|
}
|
|
|
|
hh3cHPEOCCltEthPortType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1),
|
|
debug(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Control CLT ethernet ports' type,
|
|
normal : port which used for normal translation,
|
|
debug : port which used for debug.
|
|
"
|
|
::= { hh3cHPEOCCltVlanManEntry 1 }
|
|
|
|
--
|
|
-- hh3cHPEOCCltSysManTable
|
|
--
|
|
hh3cHPEOCCltSysManTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCCltSysManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table implements the management of CLT(Coax Line Terminal).
|
|
"
|
|
::= { hh3cHPEOCSystem 3 }
|
|
|
|
hh3cHPEOCCltSysManEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCCltSysManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCCltSysManTable.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hh3cHPEOCCltSysManTable 1 }
|
|
|
|
Hh3cHPEOCCltSysManEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCCltDescr DisplayString,
|
|
hh3cHPEOCCltFwVersion DisplayString,
|
|
hh3cHPEOCCltLinkState INTEGER
|
|
}
|
|
|
|
hh3cHPEOCCltDescr OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..126))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Set the description of CLT.
|
|
"
|
|
::= { hh3cHPEOCCltSysManEntry 1 }
|
|
|
|
hh3cHPEOCCltFwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
EOC firmware version. If the object length is
|
|
zero, it means the version is unknown.
|
|
"
|
|
::= { hh3cHPEOCCltSysManEntry 2 }
|
|
|
|
hh3cHPEOCCltLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
physicaldown(1),
|
|
linkdown(2),
|
|
linkup(3),
|
|
loopback(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's link state. The physicaldown(1) state indicates
|
|
that the CLT is not powered on. The linkdown(2) state indicates
|
|
that the CLT is powered on, but registers fail. The linkup(3)
|
|
state indicates that the CLT is powered on, and registers
|
|
successful. The loopback(4) state indecates that the CLT is
|
|
powered on and registers successful, but loopback has detected.
|
|
"
|
|
::= { hh3cHPEOCCltSysManEntry 3 }
|
|
|
|
--
|
|
-- hh3cHPEOCCnuSysManTable
|
|
--
|
|
hh3cHPEOCCnuSysManTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCCnuSysManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table implements the management of CNUs.
|
|
"
|
|
::= { hh3cHPEOCSystem 4 }
|
|
|
|
hh3cHPEOCCnuSysManEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCCnuSysManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCCnuSysManTable.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hh3cHPEOCCnuSysManTable 1 }
|
|
|
|
Hh3cHPEOCCnuSysManEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCCnuBcastControl TruthValue,
|
|
hh3cHPEOCCnuAnonymStatus TruthValue,
|
|
hh3cHPEOCCnuMacLimit Unsigned32
|
|
}
|
|
|
|
hh3cHPEOCCnuBcastControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Broadcast storm suppression status.
|
|
true(1) - Broadcast storm suppression enable.
|
|
false(2) - Broadcast storm suppression disable.
|
|
"
|
|
::= { hh3cHPEOCCnuSysManEntry 1 }
|
|
|
|
hh3cHPEOCCnuAnonymStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Anonymity status.
|
|
true(1) - the user which uses the CNU is anonymous.
|
|
false(2) - the user which uses the CNU has an account.
|
|
"
|
|
::= { hh3cHPEOCCnuSysManEntry 2 }
|
|
|
|
hh3cHPEOCCnuMacLimit OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Configure the max number of MAC address entries which can access
|
|
through the CNU, it ranges from 1 to 8.
|
|
Otherwise,
|
|
If configure 0, the CNU won't limit the MAC address entry.
|
|
If configure 0xFF, it means no MAC address entry can access the CNU.
|
|
"
|
|
::= { hh3cHPEOCCnuSysManEntry 3 }
|
|
|
|
hh3cHPEOCCltAutoUpgrade OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Auto upgrade Status.
|
|
true(1) - The firmware of the CNU will be auto changed by CLT.
|
|
false(2)- The firmware of the CNU will not be auto changed.
|
|
"
|
|
DEFVAL
|
|
{
|
|
false
|
|
}
|
|
::= { hh3cHPEOCSystem 5 }
|
|
|
|
hh3cHPEOCOnLineCnuNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The total number of the online CNU(s).
|
|
"
|
|
::= { hh3cHPEOCSystem 6 }
|
|
|
|
hh3cHPEOCCpuMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
EOC CPU's MAC address.
|
|
"
|
|
::= { hh3cHPEOCSystem 7 }
|
|
|
|
hh3cHPEOCOffLineCnuNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The total number of the offline CNU(s).
|
|
"
|
|
::= { hh3cHPEOCSystem 8 }
|
|
|
|
hh3cHPEOCDownLoadCNUFWResult OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Download CNU firmware result.
|
|
"
|
|
::= { hh3cHPEOCSystem 9 }
|
|
|
|
hh3cHPEOCCltAutoUpgradeType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
flash(1),
|
|
ftp(2),
|
|
tftp(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Type of auto upgrade status.
|
|
It depends on hh3cHPEOCCltAutoUpgrade status.
|
|
flash - The CLT auto upgrade the firmware inside its flash
|
|
to the CNUs.
|
|
ftp - First download the firmware from FTP server to the CLT,
|
|
then the CLT auto upgrade the firmware to the CNUs.
|
|
tftp - First download the firmware from TFTP server to the CLT,
|
|
then the CLT auto upgrade the firmware to the CNUs.
|
|
"
|
|
::= { hh3cHPEOCSystem 10 }
|
|
|
|
hh3cHPEOCAutoUpObjects OBJECT IDENTIFIER ::= { hh3cHPEOCSystem 11 }
|
|
|
|
hh3cHPEOCServerAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The address of remote host acting as server for operation.
|
|
The default value is 0.0.0.0
|
|
"
|
|
::= { hh3cHPEOCAutoUpObjects 1 }
|
|
|
|
hh3cHPEOCServerUser OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
When using ftp to transfer files, the user name must be
|
|
specified through this node. It contains 1 to 30 characters.
|
|
"
|
|
::= { hh3cHPEOCAutoUpObjects 2 }
|
|
|
|
hh3cHPEOCServerPassword OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Remote user password for copying via ftp protocol. Optionally,
|
|
this object may be ignored for protocols other than ftp.
|
|
It contains 1 to 31 characters.
|
|
"
|
|
::= { hh3cHPEOCAutoUpObjects 3 }
|
|
|
|
hh3cHPEOCCltLoopbackDetect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
false(0),
|
|
true(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Loopback detect Status.
|
|
true(1) - The loopback detect is enabled.
|
|
false(0)- The loopback detect is disabled.
|
|
"
|
|
::= { hh3cHPEOCSystem 12 }
|
|
|
|
hh3cHPEOCTemplateEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
false(0),
|
|
true(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Use template for white-list cnu.
|
|
true(1) - Use template is enabled.
|
|
false(0)- Use template detect is disabled.
|
|
"
|
|
::= { hh3cHPEOCSystem 13 }
|
|
|
|
--
|
|
-- hh3cHPEOCCableInfo
|
|
--
|
|
hh3cHPEOCCableInfo OBJECT IDENTIFIER ::= { hh3cHPEOC 2 }
|
|
|
|
|
|
--
|
|
-- hh3cHPEOCCableInfoTable
|
|
--
|
|
|
|
hh3cHPEOCCableInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCCableInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table defines the primary parameters of the
|
|
cable information.
|
|
"
|
|
::= { hh3cHPEOCCableInfo 1 }
|
|
|
|
hh3cHPEOCCableInfoEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCCableInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCCableInfoTable.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hh3cHPEOCCableInfoTable 1 }
|
|
|
|
|
|
Hh3cHPEOCCableInfoEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCFECErrors Counter64,
|
|
hh3cHPEOCAvgBitsPerCarrier Unsigned32,
|
|
hh3cHPEOCAvgSNRPerCarrier Integer32,
|
|
hh3cHPEOCAvgInPBCRCErrors Unsigned32,
|
|
hh3cHPEOCInTotalPkts Counter64,
|
|
hh3cHPEOCAvgOutPower Integer32,
|
|
hh3cHPEOCAvgOutPBCRCErrors Unsigned32,
|
|
hh3cHPEOCOutTotalPkts Counter64
|
|
}
|
|
|
|
hh3cHPEOCFECErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's FEC bits errors ratio. FEC means the
|
|
payload Forward Error Correction. It's a technology of
|
|
controlling errors. Packets in transmission is checked by
|
|
the receiver, if error occurs, the receiver will announce
|
|
the sender to resend.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 1 }
|
|
|
|
hh3cHPEOCAvgBitsPerCarrier OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's average bits per carrier.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 2 }
|
|
|
|
hh3cHPEOCAvgSNRPerCarrier OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's signal noise ratio(SNR) bits per carrier.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 3 }
|
|
|
|
hh3cHPEOCAvgInPBCRCErrors OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The input PB CRC errors on average.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 4 }
|
|
|
|
hh3cHPEOCInTotalPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The total number of packets(including bad packets)
|
|
received on this interface.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 5 }
|
|
|
|
hh3cHPEOCAvgOutPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's power sent on average, the unit is db.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 6 }
|
|
|
|
hh3cHPEOCAvgOutPBCRCErrors OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's physical block(PB) cyclic redundancy
|
|
check(CRC) errors sent on average.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 7 }
|
|
|
|
hh3cHPEOCOutTotalPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The total count of the packets(including bad packets)
|
|
sent on this interface.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 8 }
|
|
|
|
--
|
|
-- hh3cHPEOCBitPerSymbolTable
|
|
--
|
|
|
|
hh3cHPEOCBitPerSymbolTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCBitPerSymbolEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table defines the bits per symbol parameters of the
|
|
cable line.
|
|
"
|
|
::= { hh3cHPEOCCableInfo 2 }
|
|
|
|
hh3cHPEOCBitPerSymbolEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCBitPerSymbolEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCBitPerSymbolTable.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex,
|
|
hh3cHPEOCBitPerSymbolIndex
|
|
}
|
|
::= { hh3cHPEOCBitPerSymbolTable 1 }
|
|
|
|
Hh3cHPEOCBitPerSymbolEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCBitPerSymbolIndex Unsigned32,
|
|
hh3cHPEOCBitPerSymbol OCTET STRING
|
|
}
|
|
|
|
hh3cHPEOCBitPerSymbolIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The index of the hh3cHPEOCBitPerSymbolTable.
|
|
"
|
|
::= { hh3cHPEOCBitPerSymbolEntry 1 }
|
|
|
|
hh3cHPEOCBitPerSymbol OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
hh3cHPEOCBitPerSymbol returns all the bits per symbol on the fixed
|
|
frequency. Each 4 bits stand for one value, all the values
|
|
picking-up will make up a cable bit map.
|
|
"
|
|
::= { hh3cHPEOCBitPerSymbolEntry 2 }
|
|
|
|
--
|
|
-- hh3cHPEOCTemplate
|
|
--
|
|
|
|
hh3cHPEOCTemplate OBJECT IDENTIFIER ::= { hh3cHPEOC 3 }
|
|
|
|
--
|
|
-- hh3cHPEOCTemplateGlobalTable
|
|
--
|
|
|
|
hh3cHPEOCTemplateGlobalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCTemplateGlobalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table defines the global parameters of the
|
|
Template information.
|
|
"
|
|
::= { hh3cHPEOCTemplate 1 }
|
|
|
|
hh3cHPEOCTemplateGlobalEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCTemplateGlobalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCTemplateGlobalTable.
|
|
"
|
|
INDEX
|
|
{
|
|
hh3cHPEOCTemplateIndex
|
|
}
|
|
::= { hh3cHPEOCTemplateGlobalTable 1 }
|
|
|
|
Hh3cHPEOCTemplateGlobalEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCTemplateIndex Integer32,
|
|
hh3cHPEOCTemplateType Integer32,
|
|
hh3cHPEOCTemplateName DisplayString,
|
|
hh3cHPEOCTemplateDescr DisplayString,
|
|
hh3cHPEOCTemplateCnuMaxDownBW Integer32,
|
|
hh3cHPEOCTemplateCnuMaxUpBW Integer32,
|
|
hh3cHPEOCTemplateCnuBcastControl TruthValue,
|
|
hh3cHPEOCTemplateCnuMacLimit Unsigned32,
|
|
hh3cHPEOCTemplateCb201VlanEn TruthValue,
|
|
hh3cHPEOCTemplateRowStatus RowStatus
|
|
}
|
|
|
|
hh3cHPEOCTemplateIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The index of cable Template.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 1 }
|
|
|
|
hh3cHPEOCTemplateType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
switch(1),
|
|
gateway(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable Template's type, can not change after create it.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 2 }
|
|
|
|
hh3cHPEOCTemplateName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable Template's name, it's recommended to set it
|
|
uniquely and understandably. Length: 1 to 15 characters.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 3 }
|
|
|
|
hh3cHPEOCTemplateDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable Template's description. Length: 0 to 63 characters.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 4 }
|
|
|
|
hh3cHPEOCTemplateCnuMaxDownBW OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Maximum downstream bandwidth allowed for the CNU,
|
|
measured in Kbit/s, ranges from 0 to 16384, and must be multiples of 64.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 5 }
|
|
|
|
hh3cHPEOCTemplateCnuMaxUpBW OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Maximum upstream bandwidth allowed for the CNU,
|
|
measured in Kbit/s, ranges from 0 to 16384, and must be multiples of 64.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 6 }
|
|
|
|
hh3cHPEOCTemplateCnuBcastControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Broadcast storm suppression status.
|
|
true(1) - Broadcast storm suppression enable.
|
|
false(2) - Broadcast storm suppression disable.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 7 }
|
|
|
|
hh3cHPEOCTemplateCnuMacLimit OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Configure the max number of MAC address entries which can access
|
|
through the CNU, it ranges from 1 to 8.
|
|
Otherwise,
|
|
If configure 0, the CNU won't limit the MAC address entry.
|
|
If configure 0xFF, it means no MAC address entry can access the CNU.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 8 }
|
|
|
|
hh3cHPEOCTemplateCb201VlanEn OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Use for Cb201 cnu only.
|
|
true(1) - Enable vlan insert function.
|
|
false(2) - Disable vlan insert function.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 9 }
|
|
|
|
hh3cHPEOCTemplateRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Operation status.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 10 }
|
|
|
|
--
|
|
-- hh3cHPEOCTemplateSwitchTable
|
|
--
|
|
|
|
hh3cHPEOCTemplateSwitchTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCTemplateSwitchEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table defines the port parameters of the
|
|
switch type cnu. it's not affect on the type of gateway Template.
|
|
"
|
|
::= { hh3cHPEOCTemplate 2 }
|
|
|
|
hh3cHPEOCTemplateSwitchEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCTemplateSwitchEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCTemplateSwitchTable.
|
|
"
|
|
INDEX
|
|
{
|
|
hh3cHPEOCTemplateIndex,
|
|
hh3cHPEOCTemplateUniIndex
|
|
}
|
|
::= { hh3cHPEOCTemplateSwitchTable 1 }
|
|
|
|
Hh3cHPEOCTemplateSwitchEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCTemplateUniIndex Integer32,
|
|
hh3cHPEOCTemplateUniSpeed INTEGER,
|
|
hh3cHPEOCTemplateUniDuplex INTEGER,
|
|
hh3cHPEOCTemplateUniPriority Integer32,
|
|
hh3cHPEOCTemplateUniFlowControl TruthValue,
|
|
hh3cHPEOCTemplateUniUpLineRate Unsigned32,
|
|
hh3cHPEOCTemplateUniDownLineRate Unsigned32,
|
|
hh3cHPEOCTemplateUniAdminStatus INTEGER,
|
|
hh3cHPEOCTemplateUniVLANType INTEGER,
|
|
hh3cHPEOCTemplateUniPvid Integer32,
|
|
hh3cHPEOCTemplateUniVlanTag INTEGER
|
|
}
|
|
|
|
hh3cHPEOCTemplateUniIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The index value which uniquely identifies the FE
|
|
interface of the CNU.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 1 }
|
|
|
|
hh3cHPEOCTemplateUniSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
auto(1),
|
|
s10M(10),
|
|
s100M(100)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
User network interface speed.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 2 }
|
|
|
|
hh3cHPEOCTemplateUniDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full(1),
|
|
half(2),
|
|
auto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
User network interface mode.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 3 }
|
|
|
|
hh3cHPEOCTemplateUniPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The default ingress User Priority for this port. This
|
|
only has effect on media, such as Ethernet, that do not
|
|
support native User Priority.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 4 }
|
|
|
|
hh3cHPEOCTemplateUniFlowControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flow control status.
|
|
true(1) - Flow control status enable.
|
|
false(2) - Flow control status disable."
|
|
DEFVAL
|
|
{
|
|
false
|
|
}
|
|
::= { hh3cHPEOCTemplateSwitchEntry 5 }
|
|
|
|
hh3cHPEOCTemplateUniUpLineRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The max speed upload in units of 1,024 bits per second
|
|
on this interface. The value should between 0 and 8Mbps.
|
|
If the value is 0, it means that the upload speed is only
|
|
restricted by the physical line.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 6 }
|
|
|
|
hh3cHPEOCTemplateUniDownLineRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The max speed download in units of 1,024 bits per second
|
|
on this interface. The value should between 0 and 8Mbps.
|
|
If the value is 0, it means that the download speed is only
|
|
restricted by the physical line.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 7 }
|
|
|
|
hh3cHPEOCTemplateUniAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Control if open or close the UNI. If choose up(1), means the UNI is
|
|
opened and packets can pass it. If choose down(2), means the UNI is
|
|
closed and all packets will be discard.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 8 }
|
|
|
|
hh3cHPEOCTemplateUniVLANType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
access(1),
|
|
trunk(2),
|
|
hybrid(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"port vlan types.
|
|
hybrid (3) port can carry multiple VLANs.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 9 }
|
|
|
|
hh3cHPEOCTemplateUniPvid OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4094)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The PVID, the VLAN ID assigned to untagged frames or
|
|
Priority-Tagged frames received on this port.
|
|
"
|
|
REFERENCE
|
|
"
|
|
IEEE 802.1Q/D11 Section 12.10.1.1
|
|
"
|
|
DEFVAL
|
|
{
|
|
1
|
|
}
|
|
::= { hh3cHPEOCTemplateSwitchEntry 10 }
|
|
|
|
hh3cHPEOCTemplateUniVlanTag OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
tagged(1),
|
|
untagged(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
VLAN is set tagged or untagged.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 11 }
|
|
|
|
--
|
|
-- hh3cHPEOCCnuAccess
|
|
--
|
|
hh3cHPEOCCnuAccess OBJECT IDENTIFIER ::= { hh3cHPEOC 4 }
|
|
|
|
--
|
|
-- hh3cHPEOCCnuAccessTable
|
|
--
|
|
|
|
hh3cHPEOCCnuAccessTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCCnuAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table defines the global parameters of the
|
|
cnu type permitting to access.
|
|
"
|
|
::= { hh3cHPEOCCnuAccess 1 }
|
|
|
|
hh3cHPEOCCnuAccessEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCCnuAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCCnuAccessTable.
|
|
"
|
|
INDEX
|
|
{
|
|
hh3cHPEOCCnuAccessIndex
|
|
}
|
|
::= { hh3cHPEOCCnuAccessTable 1 }
|
|
|
|
|
|
Hh3cHPEOCCnuAccessEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCCnuAccessIndex Integer32,
|
|
hh3cHPEOCCnuHFID DisplayString,
|
|
hh3cHPEOCManuInfo DisplayString,
|
|
hh3cHPEOCCnuType Integer32,
|
|
hh3cHPEOCCnuSwitchType Integer32,
|
|
hh3cHPEOCCnuUniNum Integer32,
|
|
hh3cHPEOCCnuPhy2Uni OCTET STRING,
|
|
hh3cHPEOCCnuAccessRowStatus RowStatus
|
|
}
|
|
|
|
hh3cHPEOCCnuAccessIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The index value which uniquely identifies the
|
|
manuinfo of the CNU.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 1 }
|
|
|
|
hh3cHPEOCCnuHFID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The Cnu's HFID. Every type Cnu has it's unique HFID.
|
|
Length: 1 to 64 characters.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 2 }
|
|
|
|
hh3cHPEOCManuInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The Cnu's manufactory infofamiont.
|
|
Length: 0 to 63 characters.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 3 }
|
|
|
|
hh3cHPEOCCnuType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
switch(1),
|
|
gateway(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The Cnu's function type.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 4 }
|
|
|
|
hh3cHPEOCCnuSwitchType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rtl8306e(1),
|
|
ar8236(2),
|
|
mv6061(3),
|
|
mv6031(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The Cnu's switch chip type. It's useless for gataway type cnu.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 5 }
|
|
|
|
hh3cHPEOCCnuUniNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Uni number of the Cnu. It's useless for gataway type cnu.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 6 }
|
|
|
|
hh3cHPEOCCnuPhy2Uni OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Reflection from phy port to uni port of the cnu.
|
|
It's useless for gataway type cnu.
|
|
For example, phy port 0,1,2,3 is reflect to uni port
|
|
1,2,3,4, then the value of this mib is {0,1,2,3}
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 7 }
|
|
|
|
hh3cHPEOCCnuAccessRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Operation status.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 8 }
|
|
|
|
END
|