towerops/priv/mibs/cisco/CISCOSB-CPU-COUNTERS-MIB
Graham McIntire b4f8b40b7f
Include MIB files in Docker image instead of using PVC
- Remove PVC volume mount from k8s/deployment.yaml
- Delete k8s/mib-pvc.yaml (no longer needed)
- Update .gitignore to commit MIB files to git
- Add mix import_mibs task to copy MIBs from LibreNMS
- Add all MIB files from priv/mibs/ to git

This fixes the multi-attach volume error in Kubernetes where new pods
couldn't start because the RWO (ReadWriteOnce) PVC was attached to the
old pod. MIBs are now part of the Docker image and can be used by all
pods simultaneously.
2026-01-19 14:01:03 -06:00

170 lines
5.2 KiB
Text

CISCOSB-CPU-COUNTERS-MIB DEFINITIONS ::= BEGIN
IMPORTS
switch001 FROM CISCOSB-MIB
Counter32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI
DisplayString,
TruthValue FROM SNMPv2-TC;
-- module
rlCpuCounters MODULE-IDENTITY
LAST-UPDATED "2007010600Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Postal: 170 West Tasman Drive
San Jose , CA 95134-1706
USA
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
DESCRIPTION
"CPU Counter MIBs"
REVISION "200705150000Z"
DESCRIPTION
"Initial revision."
::={ switch001 124 }
-- table
rlCpuCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlCpuCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of rx&tx counter, the key is cpuCounters"
::= { rlCpuCounters 1 }
--entry:
rlCpuCountersEntry OBJECT-TYPE
SYNTAX RlCpuCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of rx&tx counters, the key is cpuCounters"
INDEX { rlCpuCountersTarget }
::= { rlCpuCountersTable 1 }
--entry content
RlCpuCountersEntry ::= SEQUENCE {
rlCpuCountersTarget INTEGER,
rlCpuCountersTxBC Counter32,
rlCpuCountersTxMC Counter32,
rlCpuCountersTxUC Counter32,
rlCpuCountersTxOctets Counter32,
rlCpuCountersRxBC Counter32,
rlCpuCountersRxMC Counter32,
rlCpuCountersRxUC Counter32,
rlCpuCountersRxOctets Counter32
}
--field definition:
rlCpuCountersTarget OBJECT-TYPE
SYNTAX INTEGER {
cpuCounters (0)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Packet type can be Multicast (MC), Broadcast (BC) or Unicast(UC)"
::= { rlCpuCountersEntry 1 }
rlCpuCountersTxBC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received broadcast packets."
::= { rlCpuCountersEntry 2 }
rlCpuCountersTxMC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted multicast packets."
::= { rlCpuCountersEntry 3 }
rlCpuCountersTxUC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted unicast packets."
::= { rlCpuCountersEntry 4 }
rlCpuCountersTxOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of transmitted octets."
::= { rlCpuCountersEntry 5 }
rlCpuCountersRxBC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received broadcast packets."
::= { rlCpuCountersEntry 6 }
rlCpuCountersRxMC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received mutlicast packets."
::= { rlCpuCountersEntry 7 }
rlCpuCountersRxUC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received unicast packets."
::= { rlCpuCountersEntry 8 }
rlCpuCountersRxOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received octets"
::= { rlCpuCountersEntry 9 }
-- rlCpuCountersReset:
rlCpuCountersReset OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting true to this MIB object will reset the CPU counters."
DEFVAL { false}
::= { rlCpuCounters 2 }
-- rlCpuCountersEnabled:
rlCpuCountersEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"True - feature is enabled, false - feature is disabled "
DEFVAL { false}
::= { rlCpuCounters 3 }
END