- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
1681 lines
59 KiB
Text
1681 lines
59 KiB
Text
|
|
OCCAM-MLT-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
occamGenericMonitorModules
|
|
FROM OCCAM-REG-MODULE
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY,
|
|
Integer32, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI;
|
|
|
|
occamMltMib MODULE-IDENTITY
|
|
LAST-UPDATED "200104271051Z"
|
|
ORGANIZATION "Occam Networks"
|
|
CONTACT-INFO "email support@occamnetworks.com"
|
|
DESCRIPTION
|
|
"This mib module describes objects used
|
|
to perform Metallic Line Testing on customer
|
|
access lines and to provide results."
|
|
|
|
REVISION "200104271051Z"
|
|
DESCRIPTION "Reformatted certain text"
|
|
|
|
REVISION "200704170000Z"
|
|
DESCRIPTION "replace kOhm with Ohm in DC resistance
|
|
UNITS"
|
|
|
|
REVISION "200702220000Z"
|
|
DESCRIPTION "remove DISPLAY-HINT"
|
|
|
|
REVISION "200609261000Z"
|
|
DESCRIPTION "Removed Gr909 from fuse test result names"
|
|
|
|
REVISION "200602220135Z"
|
|
DESCRIPTION "Initial version."
|
|
::= { occamGenericMonitorModules 3 }
|
|
|
|
-- TEXTUAL-CONVENTIONS --
|
|
|
|
MltTestType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A selection value for requesting or forcing
|
|
a test. A requested test will only run if the
|
|
port is not in use. A forced test will
|
|
immediately shut the port and run the test."
|
|
SYNTAX INTEGER { request ( 1 ) ,
|
|
force ( 2 ) }
|
|
|
|
MltTestStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of test status:
|
|
none = no test has been requested.
|
|
mltbusy = another port is currently being tested.
|
|
complete = the last requested test has completed.
|
|
portInUse = the last requested port is in use,
|
|
the test was not run. Rerunning the test as
|
|
'forced' will shut the port and run the test.
|
|
inProgress = the last requested test is still
|
|
running. mltError = the mlt program reported an
|
|
error and aborted the test.Check the mltErrorText
|
|
object.
|
|
mltNotResponding = the mlt program didn't return
|
|
a result."
|
|
SYNTAX INTEGER {
|
|
none ( 1 ) ,
|
|
mltBusy ( 2 ),
|
|
complete ( 3 ) ,
|
|
portInUse ( 4 ) ,
|
|
inProgress ( 5 ),
|
|
mltError ( 6 ),
|
|
mltNotResponding ( 7 ) }
|
|
|
|
MltTestIdentifier ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An mlt test selection value."
|
|
SYNTAX INTEGER {
|
|
statusSuite ( 1 ) ,
|
|
mltSuite ( 2 ) ,
|
|
activeModeVoltages ( 3 ) ,
|
|
highImpedanceModeVoltages ( 4 ) ,
|
|
dcResistance ( 5 ) ,
|
|
capacitance ( 6 ) ,
|
|
loopDetect ( 7 ) ,
|
|
loopLength ( 8 ) }
|
|
|
|
MltTestHookState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An mlt test hook state value."
|
|
SYNTAX INTEGER {
|
|
onhook ( 1 ) ,
|
|
offhook ( 2 ),
|
|
notAvailable ( 3 ) }
|
|
|
|
MltTestPassFail ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An mlt test pass/fail value."
|
|
SYNTAX INTEGER {
|
|
pass ( 1 ) ,
|
|
fail ( 2 ),
|
|
notAvailable ( 3 ) }
|
|
|
|
MltTestRingerResult ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An mlt ringer test result value."
|
|
SYNTAX INTEGER {
|
|
pass ( 1 ) ,
|
|
fail ( 2 ),
|
|
notAvailable ( 3 ),
|
|
low ( 4 ) }
|
|
|
|
MltTestYesNo ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An mlt test pass/fail value."
|
|
SYNTAX INTEGER {
|
|
yes ( 1 ) ,
|
|
no ( 2 ),
|
|
notAvailable ( 3 ) }
|
|
|
|
-- The Metallic Loop Test Configuration group
|
|
|
|
mltTestConfig OBJECT IDENTIFIER
|
|
::= { occamMltMib 1 }
|
|
|
|
|
|
-- The Metallic Loop Test Status group
|
|
|
|
mltTestStatus OBJECT IDENTIFIER
|
|
::= { occamMltMib 2 }
|
|
|
|
|
|
-- The Metallic Loop Test Results group
|
|
|
|
mltTestResults OBJECT IDENTIFIER
|
|
::= { occamMltMib 3 }
|
|
|
|
-- The Metallic Loop Test Notifications group
|
|
|
|
mltTestNotifications OBJECT IDENTIFIER
|
|
::= { occamMltMib 4 }
|
|
|
|
|
|
-- Objects of the MLT Configuration group
|
|
|
|
mltTestIdentifier OBJECT-TYPE
|
|
SYNTAX MltTestIdentifier
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects the mlt test to be run.
|
|
Setting this value starts a test.
|
|
|
|
This is a required parameter.
|
|
|
|
Approximate expected test durations are as
|
|
follows:
|
|
|
|
statusSuite 1 second
|
|
mltSuite 1 minute
|
|
activeModeVoltages 3 seconds
|
|
highImpedanceModeVoltages 9 seconds
|
|
dcResistance 18 seconds
|
|
capacitance 18 seconds
|
|
loopDetect 9 seconds
|
|
loopLength 9 seconds."
|
|
::= { mltTestConfig 1 }
|
|
|
|
mltTestType OBJECT-TYPE
|
|
SYNTAX MltTestType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects if a test is requested (only run if port
|
|
is not in use) or forced.
|
|
This is an optional parameter. If not specified,
|
|
the request option is used."
|
|
::= { mltTestConfig 2 }
|
|
|
|
mltTestPort OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 48 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects voice channel on which test will be run.
|
|
This is a required parameter."
|
|
::= { mltTestConfig 3 }
|
|
|
|
mltDcResistanceRange OBJECT-TYPE
|
|
SYNTAX Integer32 ( 0 .. 3 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects DC Resistance range value.
|
|
This is an optional paramater. Default is 0
|
|
(auto mode)."
|
|
::= { mltTestConfig 4 }
|
|
|
|
mltLoopLengthMultiplier OBJECT-TYPE
|
|
SYNTAX Integer32 ( 10 .. 200 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects loop length multiplier in nf. This is an
|
|
optional parameter. If not specified an internal
|
|
default value of 83nF/mile is used."
|
|
::= { mltTestConfig 5 }
|
|
|
|
mltLoopDetectThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 ( 5 .. 200 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects the detection threshold in nF.
|
|
This is an optional parameter. If not supplied,
|
|
a loop detection threshold of 10nF is used."
|
|
::= { mltTestConfig 6 }
|
|
|
|
|
|
-- Objects of the MLT Test Status group
|
|
|
|
mltLastTestStatus OBJECT-TYPE
|
|
SYNTAX MltTestStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of the last run mlt test.
|
|
Given that the various mlt tests take several
|
|
seconds to 1 1/2 minutes to run, it is suggested
|
|
that status polls be spaced 10-20 seconds apart.
|
|
Additionally, a monitoring application could
|
|
wait for the testComplete notification."
|
|
::= { mltTestStatus 1 }
|
|
|
|
mltErrorText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the textual error in the case of an
|
|
aborted test."
|
|
::= { mltTestStatus 2 }
|
|
|
|
|
|
-- Objects of the MLT Test Results group
|
|
|
|
-- mlt status results table
|
|
mltStatusResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltStatusResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the status test
|
|
suite."
|
|
::= { mltTestResults 1 }
|
|
|
|
mltStatusResultsEntry OBJECT-TYPE
|
|
SYNTAX MltStatusResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of status suite tests.
|
|
|
|
Note that a numerical result value of -999 means
|
|
that there was an error of some sort and the
|
|
value could not be measured."
|
|
INDEX { mltTestPort }
|
|
::= { mltStatusResultsTable 1 }
|
|
|
|
MltStatusResultsEntry ::= SEQUENCE {
|
|
mltStatusAlarm OCTET STRING,
|
|
mltStatusHookState MltTestHookState,
|
|
mltStatusTransversalCurrent Integer32,
|
|
mltStatusLongitudinalCurrent Integer32,
|
|
mltStatusTipVoltage Integer32,
|
|
mltStatusRingVoltage Integer32,
|
|
mltStatusTipRingVoltage Integer32,
|
|
mltStatusVdd Integer32
|
|
}
|
|
|
|
|
|
mltStatusAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when
|
|
status test was run."
|
|
::= { mltStatusResultsEntry 1 }
|
|
|
|
|
|
mltStatusHookState OBJECT-TYPE
|
|
SYNTAX MltTestHookState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates line hook state when status test was
|
|
run."
|
|
::= { mltStatusResultsEntry 2 }
|
|
|
|
|
|
mltStatusTransversalCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates transversal current when status test
|
|
was run."
|
|
::= { mltStatusResultsEntry 3 }
|
|
|
|
|
|
mltStatusLongitudinalCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates Longitudinal current when status test
|
|
was run."
|
|
::= { mltStatusResultsEntry 4 }
|
|
|
|
|
|
mltStatusTipVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates tip voltage when status test was run."
|
|
::= { mltStatusResultsEntry 5 }
|
|
|
|
|
|
mltStatusRingVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates ring voltage when status test was run."
|
|
::= { mltStatusResultsEntry 6 }
|
|
|
|
mltStatusTipRingVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates tip-ring voltage when status test was
|
|
run."
|
|
::= { mltStatusResultsEntry 7 }
|
|
|
|
|
|
mltStatusVdd OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates Vdd when status test was run."
|
|
::= { mltStatusResultsEntry 8 }
|
|
|
|
-- mlt test results table
|
|
mltTestResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltTestResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the mlt test suite.
|
|
Note that a numerical result value of -999 means
|
|
that there was an error of some sort and the
|
|
value could not be measured.
|
|
Also, a resistance value of 9999 means that the
|
|
result was greater than 1000 kOhms, but the exact
|
|
value could not be measured."
|
|
::= { mltTestResults 2 }
|
|
|
|
mltTestResultsEntry OBJECT-TYPE
|
|
SYNTAX MltTestResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt suite tests."
|
|
INDEX { mltTestPort }
|
|
::= { mltTestResultsTable 1 }
|
|
|
|
MltTestResultsEntry ::= SEQUENCE {
|
|
mltTestAlarm OCTET STRING,
|
|
mltTestHookState MltTestHookState,
|
|
mltTestVdd Integer32,
|
|
mltTestActiveModeVoltagesVdctr Integer32,
|
|
mltTestActiveModeVoltagesVdctg Integer32,
|
|
mltTestActiveModeVoltagesVdcrg Integer32,
|
|
mltTestActiveModeVoltagesVactr Integer32,
|
|
mltTestActiveModeVoltagesVactg Integer32,
|
|
mltTestActiveModeVoltagesVacrg Integer32,
|
|
mltTestHighImpedanceModeVoltagesVdctr Integer32,
|
|
mltTestHighImpedanceModeVoltagesVdctg Integer32,
|
|
mltTestHighImpedanceModeVoltagesVdcrg Integer32,
|
|
mltTestHighImpedanceModeVoltagesVactr Integer32,
|
|
mltTestHighImpedanceModeVoltagesVactg Integer32,
|
|
mltTestHighImpedanceModeVoltagesVacrg Integer32,
|
|
mltTestDcCurrentsItransversal Integer32,
|
|
mltTestDcCurrentsIlongitudinal Integer32,
|
|
mltTestDcCurrentsItip Integer32,
|
|
mltTestDcCurrentsIring Integer32,
|
|
mltTestCapacitanceCeqtr Integer32,
|
|
mltTestCapacitanceCeqtg Integer32,
|
|
mltTestCapacitanceCeqrg Integer32,
|
|
mltTestResistanceRtr Integer32,
|
|
mltTestResistanceRtg Integer32,
|
|
mltTestResistanceRrg Integer32,
|
|
mltTestGr909HazardousPotentialTestResult MltTestPassFail,
|
|
mltTestGr909ForeignEmfTestResult MltTestPassFail,
|
|
mltTestGr909FuseTestTipFuse MltTestPassFail,
|
|
mltTestGr909FuseTestRingFuse MltTestPassFail,
|
|
mltTestFuseTestTipFuse MltTestPassFail,
|
|
mltTestFuseTestRingFuse MltTestPassFail,
|
|
mltTestGr909ResistiveFaultTestResult MltTestPassFail,
|
|
mltTestGr909ReceiverOffhookTestResult MltTestPassFail,
|
|
mltTestGr909ReceiverOffhookTestResistance1 Integer32,
|
|
mltTestGr909ReceiverOffhookTestResistance2 Integer32,
|
|
mltTestGr909ReceiverOffhookTestDifference Integer32,
|
|
mltTestGr909RingerTestResult MltTestRingerResult,
|
|
mltTestGr909RingerTestRen Integer32,
|
|
mltTestErrors OCTET STRING
|
|
}
|
|
|
|
|
|
mltTestAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"GNK and OTEMP bits set by the DuSLIC will be
|
|
reported as alarms. GNK is typically cause by
|
|
ground fault or foreign voltage condition.
|
|
OTEMP is set when the DuSLIC is experiencing
|
|
thermal overload. This parameter is
|
|
non-intrusive."
|
|
::= { mltTestResultsEntry 1 }
|
|
|
|
mltTestHookState OBJECT-TYPE
|
|
SYNTAX MltTestHookState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hook state reflects the DuSLIC hook bit
|
|
(offhook/onhook). This parameter is
|
|
non-intrusive."
|
|
::= { mltTestResultsEntry 2 }
|
|
|
|
mltTestVdd OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"On HDPOTS, internal Voltage VDD will be
|
|
reported and compared to statistically derived
|
|
thresholds.
|
|
This parameter is intrusive during offhook but
|
|
will be available during onhook."
|
|
::= { mltTestResultsEntry 3 }
|
|
|
|
mltTestActiveModeVoltagesVdctr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring
|
|
in a normal no shutdown state. AC voltages for
|
|
T-R, T-G and R-G will be reported.
|
|
Active mode measurements will not be available
|
|
when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 4 }
|
|
|
|
mltTestActiveModeVoltagesVdctg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring
|
|
in a normal no shutdown state. AC voltages for
|
|
T-R, T-G and R-G will be reported.
|
|
Active mode measurements will not be available
|
|
when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 5 }
|
|
|
|
mltTestActiveModeVoltagesVdcrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring
|
|
in a normal no shutdown state. AC voltages for
|
|
T-R, T-G and R-G will be reported.
|
|
Active mode measurements will not be available
|
|
when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 6 }
|
|
|
|
mltTestActiveModeVoltagesVactr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring
|
|
in a normal no shutdown state. Thus, VT and VR
|
|
measurements should be 0 volt.
|
|
AC voltages for T-R, T-G and R-G will be
|
|
reported. Active mode measurements will not be
|
|
available when alarm is detected. This parameter
|
|
is intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 7 }
|
|
|
|
mltTestActiveModeVoltagesVactg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring
|
|
in a normal no shutdown state. Thus, VT and VR
|
|
measurements should be 0 volt. AC voltages for T-R, T-G
|
|
and R-G will be reported. Active mode measurements will
|
|
not be available when alarm is detected. This parameter
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltTestResultsEntry 8 }
|
|
|
|
mltTestActiveModeVoltagesVacrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. Thus, VT and VR measurements
|
|
should be 0 volt. AC voltages for T-R, T-G and R-G will
|
|
be reported. Active mode measurements will not be
|
|
available when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown state only."
|
|
|
|
::= { mltTestResultsEntry 9 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVdctr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 10 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVdctg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 11 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVdcrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 12 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVactr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages): In this mode, the DuSLIC tip and ring are in
|
|
high impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 13 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVactg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 14 }
|
|
|
|
mltTestHighImpedanceModeVoltagesVacrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 15 }
|
|
|
|
mltTestDcCurrentsItransversal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Four DC currents will be reported: IT, IL, It and Ir.
|
|
In normal condition, currents will be measured in
|
|
active mode. These measurements will not be available if
|
|
alarm is present."
|
|
::= { mltTestResultsEntry 16 }
|
|
|
|
mltTestDcCurrentsIlongitudinal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Four DC currents will be reported: IT, IL, It and Ir.
|
|
In normal condition, currents will be measured in active
|
|
mode. These measurements will not be available if alarm
|
|
is present."
|
|
::= { mltTestResultsEntry 17 }
|
|
|
|
mltTestDcCurrentsItip OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Four DC currents will be reported: IT, IL, It and Ir.
|
|
In normal condition, currents will be measured in active
|
|
mode. These measurements will not be available if alarm
|
|
is present."
|
|
::= { mltTestResultsEntry 18 }
|
|
|
|
mltTestDcCurrentsIring OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Four DC currents will be reported: IT, IL, It and Ir.
|
|
In normal condition, currents will be measured in active
|
|
mode. These measurements will not be available if alarm
|
|
is present."
|
|
::= { mltTestResultsEntry 19 }
|
|
|
|
mltTestCapacitanceCeqtr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal) circuit. In the presence of a
|
|
network of capacitance (figure 3), the individual
|
|
capacitance will not be resolved. The equivalent
|
|
capacitances CEQtr, CEQtg and CEQrg will be reported.
|
|
They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltTestResultsEntry 20 }
|
|
|
|
mltTestCapacitanceCeqtg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal)
|
|
circuit. In the presence of a network of capacitance
|
|
(figure 3), the
|
|
individual capacitance will not be resolved. The
|
|
equivalent capacitances CEQtr, CEQtg and CEQrg will be
|
|
reported. They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltTestResultsEntry 21 }
|
|
|
|
mltTestCapacitanceCeqrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal) circuit. In the presence of a
|
|
network of capacitance (figure 3), the individual
|
|
capacitance will not be resolved. The equivalent
|
|
capacitances CEQtr, CEQtg and CEQrg will be reported.
|
|
They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltTestResultsEntry 22 }
|
|
|
|
mltTestResistanceRtr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying 3
|
|
resistance ranges: (1) low, (2) medium, (3) high. If not
|
|
specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state `
|
|
only."
|
|
::= { mltTestResultsEntry 23 }
|
|
|
|
mltTestResistanceRtg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying
|
|
3 resistance ranges: (1) low, (2) medium, (3) high. If
|
|
not specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltTestResultsEntry 24 }
|
|
|
|
mltTestResistanceRrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying
|
|
3 resistance ranges: (1) low, (2) medium, (3) high. If
|
|
not specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltTestResultsEntry 25 }
|
|
|
|
mltTestGr909HazardousPotentialTestResult OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if the T-G or R-G ac voltage is greater
|
|
than 50 volts rms or the T-G or R-G dc voltage is
|
|
greater than 135 volts. This test will report pass/fail.
|
|
This test is intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 26 }
|
|
|
|
mltTestGr909ForeignEmfTestResult OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if the T-G or R-G ac voltage is greater
|
|
than 50 volts rms or the T-G or R-G dc voltage is
|
|
greater than 135 volts. This test will report pass/fail.
|
|
This test is intrusive and will be available in shutdown
|
|
state only."
|
|
::= { mltTestResultsEntry 27 }
|
|
|
|
mltTestGr909FuseTestTipFuse OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This test determines if these fuses are blown. This
|
|
test will return pass/fail for tip and ring. This test
|
|
will not be performed if alarm is present. This
|
|
parameter is intrusive. This test is intrusive and will
|
|
be available in shutdown state only.
|
|
|
|
This object is obsolete. Object name was changed."
|
|
::= { mltTestResultsEntry 28 }
|
|
|
|
mltTestGr909FuseTestRingFuse OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This test determines if these fuses are blown. This
|
|
test will return pass/fail for tip and ring. This test
|
|
will not be performed if alarm is present. This
|
|
parameter is intrusive. This test is intrusive and will
|
|
be available in shutdown state only.
|
|
|
|
This object is obsolete. Object name was changed."
|
|
::= { mltTestResultsEntry 29 }
|
|
|
|
mltTestFuseTestTipFuse OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test determines if these fuses are blown. This
|
|
test will return pass/fail for tip and ring. This test
|
|
will not be performed if alarm is present. This
|
|
parameter is intrusive. This test is intrusive and will
|
|
be available in shutdown state only."
|
|
::= { mltTestResultsEntry 38 }
|
|
|
|
mltTestFuseTestRingFuse OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test determines if these fuses are blown. This
|
|
test will return pass/fail for tip and ring. This test
|
|
will not be performed if alarm is present. This
|
|
parameter is intrusive. This test is intrusive and will
|
|
be available in shutdown state only."
|
|
::= { mltTestResultsEntry 39 }
|
|
|
|
mltTestGr909ResistiveFaultTestResult OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if the T-R, T-G or R-G dc resistance is
|
|
less than 150k ohm. This test will not be performed if
|
|
fuse test fails or alarm is present. This test will
|
|
return pass/fail. This test is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltTestResultsEntry 30 }
|
|
|
|
mltTestGr909ReceiverOffhookTestResult OBJECT-TYPE
|
|
SYNTAX MltTestPassFail
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if a non-linearity in the T-R dc
|
|
resistance of greater than 15% when measured at two
|
|
different voltage levels exists. This test will not be
|
|
performed if fuse test fails or alarm is present. This
|
|
test will return the DC resistances at two different
|
|
operating points and the percent difference between the
|
|
two DC resistances. This test is intrusive and will be
|
|
available in shutdown state only. "
|
|
::= { mltTestResultsEntry 31 }
|
|
|
|
mltTestGr909ReceiverOffhookTestResistance1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if a non-linearity in the T-R dc
|
|
resistance of greater than 15% when measured at two
|
|
different voltage levels exists. This test will not be
|
|
performed if fuse test fails or alarm is present. This
|
|
test will return the DC resistances at two different
|
|
operating points and the percent difference between the
|
|
two DC resistances. This test is intrusive and will be
|
|
available in shutdown state only. "
|
|
::= { mltTestResultsEntry 32 }
|
|
|
|
mltTestGr909ReceiverOffhookTestResistance2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if a non-linearity in the T-R dc
|
|
resistance of greater than 15% when measured at two
|
|
different voltage levels exists. This test will not be
|
|
performed if fuse test fails or alarm is present. This
|
|
test will return the DC resistances at two different
|
|
operating points and the percent difference between the
|
|
two DC resistances. This test is intrusive and will be
|
|
available in shutdown state only. "
|
|
::= { mltTestResultsEntry 33 }
|
|
|
|
mltTestGr909ReceiverOffhookTestDifference OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails if a non-linearity in the T-R dc
|
|
resistance of greater than 15% when measured at two
|
|
different voltage levels exists. This test will not be
|
|
performed if fuse test fails or alarm is present. This
|
|
test will return the DC resistances at two different
|
|
operating points and the percent difference between the
|
|
two DC resistances. This test is intrusive and will be
|
|
available in shutdown state only. "
|
|
::= { mltTestResultsEntry 34 }
|
|
|
|
mltTestGr909RingerTestResult OBJECT-TYPE
|
|
SYNTAX MltTestRingerResult
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails when the equivalent ringer count across
|
|
tip and ring is less than 0.175 REN or greater than 5
|
|
REN. This test will not run if fuse test fails or alarm
|
|
is present. This test will report passed/fail and the
|
|
REN number. This parameter is intrusive and will be
|
|
available in shutdown state shutdown only."
|
|
::= { mltTestResultsEntry 35 }
|
|
|
|
mltTestGr909RingerTestRen OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 REN"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test fails when the equivalent ringer count across
|
|
tip and ring is less than 0.175 REN or greater than 5
|
|
REN. This test will not run if fuse test fails or alarm
|
|
is present. This test will report passed/fail and the
|
|
REN number. This parameter is intrusive and will be
|
|
available in shutdown state shutdown only."
|
|
::= { mltTestResultsEntry 36 }
|
|
|
|
mltTestErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltTestResultsEntry 37 }
|
|
|
|
-- mlt active mode voltages results table
|
|
mltActiveModeVoltagesResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltActiveModeVoltagesResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides results of the mlt active mode
|
|
voltages test.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could not
|
|
be measured."
|
|
::= { mltTestResults 3 }
|
|
|
|
mltActiveModeVoltagesResultsEntry OBJECT-TYPE
|
|
SYNTAX MltActiveModeVoltagesResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt active mode voltages test."
|
|
INDEX { mltTestPort }
|
|
::= { mltActiveModeVoltagesResultsTable 1 }
|
|
|
|
MltActiveModeVoltagesResultsEntry ::= SEQUENCE {
|
|
mltActiveModeVoltagesVdctr Integer32,
|
|
mltActiveModeVoltagesVdctg Integer32,
|
|
mltActiveModeVoltagesVdcrg Integer32,
|
|
mltActiveModeVoltagesVactr Integer32,
|
|
mltActiveModeVoltagesVactg Integer32,
|
|
mltActiveModeVoltagesVacrg Integer32,
|
|
mltActiveModeVoltagesErrors OCTET STRING
|
|
}
|
|
|
|
mltActiveModeVoltagesVdctr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. AC voltages for T-R, T-G and
|
|
R-G will be reported.
|
|
Active mode measurements will not be available when
|
|
alarm is detected. This parameter is intrusive and will
|
|
be available in shutdown state only."
|
|
::= { mltActiveModeVoltagesResultsEntry 1 }
|
|
|
|
mltActiveModeVoltagesVdctg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. AC voltages for T-R, T-G and
|
|
R-G will be reported. Active mode measurements will not
|
|
be available when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltActiveModeVoltagesResultsEntry 2 }
|
|
|
|
mltActiveModeVoltagesVdcrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. AC voltages for T-R, T-G and
|
|
R-G will be reported. Active mode measurements will not
|
|
be available when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltActiveModeVoltagesResultsEntry 3 }
|
|
|
|
mltActiveModeVoltagesVactr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. Thus, VT and VR measurements
|
|
should be 0 volt. AC voltages for T-R, T-G and R-G will
|
|
be reported. Active mode measurements will not be
|
|
available when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltActiveModeVoltagesResultsEntry 4 }
|
|
|
|
mltActiveModeVoltagesVactg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. Thus, VT and VR measurements
|
|
should be 0 volt. AC voltages for T-R, T-G and R-G will
|
|
be reported. Active mode measurements will not be
|
|
available when alarm is detected. This parameter is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltActiveModeVoltagesResultsEntry 5 }
|
|
|
|
mltActiveModeVoltagesVacrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Mode Tip/Ring AC Voltages:
|
|
In active mode, the DuSLIC drives the tip/ring in a
|
|
normal no shutdown state. Thus, VT and VR measurements
|
|
should be 0 volt. AC voltages for T-R, T-G and R-G will
|
|
be reported.
|
|
Active mode measurements will not be available when
|
|
alarm is detected. This parameter is intrusive and will
|
|
be available in shutdown state only."
|
|
|
|
::= { mltActiveModeVoltagesResultsEntry 6 }
|
|
|
|
mltActiveModeVoltagesErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltActiveModeVoltagesResultsEntry 7 }
|
|
|
|
-- mlt high impedance mode voltages results table
|
|
mltHighImpedanceModeVoltagesResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF
|
|
MltHighImpedanceModeVoltagesResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the mlt test suite.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could not
|
|
be measured."
|
|
::= { mltTestResults 4 }
|
|
|
|
mltHighImpedanceModeVoltagesResultsEntry OBJECT-TYPE
|
|
SYNTAX MltHighImpedanceModeVoltagesResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt high impedance mode voltages test."
|
|
INDEX { mltTestPort }
|
|
::= { mltHighImpedanceModeVoltagesResultsTable 1 }
|
|
|
|
MltHighImpedanceModeVoltagesResultsEntry ::= SEQUENCE {
|
|
mltHighImpedanceModeVoltagesVdctr Integer32,
|
|
mltHighImpedanceModeVoltagesVdctg Integer32,
|
|
mltHighImpedanceModeVoltagesVdcrg Integer32,
|
|
mltHighImpedanceModeVoltagesVactr Integer32,
|
|
mltHighImpedanceModeVoltagesVactg Integer32,
|
|
mltHighImpedanceModeVoltagesVacrg Integer32,
|
|
mltHighImpedanceModeVoltagesErrors OCTET STRING
|
|
}
|
|
|
|
mltHighImpedanceModeVoltagesVdctr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 1 }
|
|
|
|
mltHighImpedanceModeVoltagesVdctg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 2 }
|
|
|
|
mltHighImpedanceModeVoltagesVdcrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vdc"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring DC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. DC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 3 }
|
|
|
|
mltHighImpedanceModeVoltagesVactr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 4 }
|
|
|
|
mltHighImpedanceModeVoltagesVactg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 5 }
|
|
|
|
mltHighImpedanceModeVoltagesVacrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Vrms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High Impedance Mode Tip/Ring AC Voltages (Foreign
|
|
Voltages):
|
|
In this mode, the DuSLIC tip and ring are in high
|
|
impedance. The measured voltages represent foreign
|
|
voltages. AC voltages for T-R, T-G and R-G will be
|
|
reported. This parameter is intrusive and will be
|
|
available in shutdown state only."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 6 }
|
|
|
|
mltHighImpedanceModeVoltagesErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltHighImpedanceModeVoltagesResultsEntry 7 }
|
|
|
|
-- mlt DC resistance results table
|
|
mltDcResistanceResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltDcResistanceResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the DC resistance test.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could not
|
|
be measured. Also, a resistance value of 9999 means
|
|
that the result was greater than 1000 kOhms, but the
|
|
exact value could not be measured."
|
|
::= { mltTestResults 5 }
|
|
|
|
mltDcResistanceResultsEntry OBJECT-TYPE
|
|
SYNTAX MltDcResistanceResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt DC resistance test."
|
|
INDEX { mltTestPort }
|
|
::= { mltDcResistanceResultsTable 1 }
|
|
|
|
MltDcResistanceResultsEntry ::= SEQUENCE {
|
|
mltDcResistanceRtr Integer32,
|
|
mltDcResistanceRtg Integer32,
|
|
mltDcResistanceRrg Integer32,
|
|
mltDcResistanceErrors OCTET STRING
|
|
}
|
|
|
|
|
|
mltDcResistanceRtr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying
|
|
3 resistance ranges: (1) low, (2) medium, (3) high. If
|
|
not specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltDcResistanceResultsEntry 1 }
|
|
|
|
mltDcResistanceRtg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying
|
|
3 resistance ranges: (1) low, (2) medium, (3) high. If
|
|
not specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltDcResistanceResultsEntry 2 }
|
|
|
|
mltDcResistanceRrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Ohm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DC resistance measurements will be based on a 3
|
|
terminal circuit model. Rtr, Rtg and Rrg will be
|
|
provided. User will have the option of specifying
|
|
3 resistance ranges: (1) low, (2) medium, (3) high. If
|
|
not specified, auto mode will be used. Resistance
|
|
measurements will not be available if fuse test fails or
|
|
alarm is present. This parameter is intrusive. This test
|
|
is intrusive and will be available in shutdown state
|
|
only."
|
|
::= { mltDcResistanceResultsEntry 3 }
|
|
|
|
mltDcResistanceErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltDcResistanceResultsEntry 4 }
|
|
|
|
-- mlt capacitance results table
|
|
mltCapacitanceResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltCapacitanceResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the mlt test suite.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could not
|
|
be measured."
|
|
::= { mltTestResults 6 }
|
|
|
|
mltCapacitanceResultsEntry OBJECT-TYPE
|
|
SYNTAX MltCapacitanceResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt capacitance test."
|
|
INDEX { mltTestPort }
|
|
::= { mltCapacitanceResultsTable 1 }
|
|
|
|
MltCapacitanceResultsEntry ::= SEQUENCE {
|
|
mltCapacitanceCeqtr Integer32,
|
|
mltCapacitanceCeqtg Integer32,
|
|
mltCapacitanceCeqrg Integer32,
|
|
mltCapacitanceErrors OCTET STRING
|
|
}
|
|
|
|
mltCapacitanceCeqtr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal) circuit. In the presence of a
|
|
network of capacitance (figure 3), the individual
|
|
capacitance will not be resolved. The equivalent
|
|
capacitances CEQtr, CEQtg and CEQrg will be reported.
|
|
They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltCapacitanceResultsEntry 1 }
|
|
|
|
mltCapacitanceCeqtg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal) circuit. In the presence of a
|
|
network of capacitance (figure 3), the individual
|
|
capacitance will not be resolved. The equivalent
|
|
capacitances CEQtr, CEQtg and CEQrg will be reported.
|
|
They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltCapacitanceResultsEntry 2 }
|
|
|
|
mltCapacitanceCeqrg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacitance measurements will support only single
|
|
element (2 terminal) circuit. In the presence of a
|
|
network of capacitance (figure 3), the individual
|
|
capacitance will not be resolved. The equivalent
|
|
capacitances CEQtr, CEQtg and CEQrg will be reported.
|
|
They represent the following:
|
|
|
|
CEQtr = Ctr + Ctg/4 + Crg/4
|
|
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
|
|
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
|
|
|
|
Capacitance measurements will not be available if fuse
|
|
test fails or alarm is present. This test is intrusive
|
|
and will be available in shutdown state only."
|
|
::= { mltCapacitanceResultsEntry 3 }
|
|
|
|
mltCapacitanceErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltCapacitanceResultsEntry 4 }
|
|
|
|
-- mlt loop detect results table
|
|
mltLoopDetectResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltLoopDetectResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the mlt loop detect test.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could not
|
|
be measured."
|
|
::= { mltTestResults 7 }
|
|
|
|
mltLoopDetectResultsEntry OBJECT-TYPE
|
|
SYNTAX MltLoopDetectResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt loop detect test."
|
|
INDEX { mltTestPort }
|
|
::= { mltLoopDetectResultsTable 1 }
|
|
|
|
MltLoopDetectResultsEntry ::= SEQUENCE {
|
|
mltLoopDetectLoopCapacitance Integer32,
|
|
mltLoopDetectDetectionThreshold Integer32,
|
|
mltLoopDetectLoopDetected MltTestYesNo,
|
|
mltLoopDetectErrors OCTET STRING
|
|
}
|
|
|
|
mltLoopDetectLoopCapacitance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop detection will be based on tip-ring capacitance
|
|
measurement. User will be able to specify the detection
|
|
threshold. If not supplied,loop detection threshold of
|
|
10 nF will be used. This test will not be available if
|
|
fuse test fails or alarm is present. This test is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltLoopDetectResultsEntry 1 }
|
|
|
|
mltLoopDetectDetectionThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop detection will be based on tip-ring capacitance
|
|
measurement. User will be able to specify the detection
|
|
threshold. If not supplied, loop detection threshold of
|
|
10 nF will be used. This test will not be available if
|
|
fuse test fails or alarm is present. This test is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltLoopDetectResultsEntry 2 }
|
|
|
|
mltLoopDetectLoopDetected OBJECT-TYPE
|
|
SYNTAX MltTestYesNo
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop detection will be based on tip-ring capacitance
|
|
measurement. User will be able to specify the detection
|
|
threshold. If not supplied, loop detection threshold
|
|
of 10 nF will be used. This test will not be available
|
|
if fuse test fails or alarm is present. This test is
|
|
intrusive and will be available in shutdown state only."
|
|
::= { mltLoopDetectResultsEntry 3 }
|
|
|
|
mltLoopDetectErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test
|
|
was run."
|
|
::= { mltLoopDetectResultsEntry 4 }
|
|
|
|
-- mlt loop length results table
|
|
mltLoopLengthResultsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MltLoopLengthResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides result of the mlt loop length test.
|
|
Note that a numerical result value of -999 means that
|
|
there was an error of some sort and the value could
|
|
not be measured."
|
|
::= { mltTestResults 8 }
|
|
|
|
mltLoopLengthResultsEntry OBJECT-TYPE
|
|
SYNTAX MltLoopLengthResultsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry holding information about results
|
|
of mlt loop length test."
|
|
INDEX { mltTestPort }
|
|
::= { mltLoopLengthResultsTable 1 }
|
|
|
|
MltLoopLengthResultsEntry ::= SEQUENCE {
|
|
mltLoopLengthCapacitanceFactor Integer32,
|
|
mltLoopLengthLoopCapacitance Integer32,
|
|
mltLoopLengthLoopLength Integer32,
|
|
mltLoopLengthUncompensatedLoopCapacitance Integer32,
|
|
mltLoopLengthUncompensatedLoopLength Integer32,
|
|
mltLoopLengthErrors OCTET STRING
|
|
}
|
|
|
|
mltLoopLengthCapacitanceFactor OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF/mile"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop length estimate will be based on tip-ring
|
|
capacitance measurement. User will be able to
|
|
specify the loop length multiplier. If not supplied,
|
|
loop length multiplier of 83 nF/ mile will be used.
|
|
This test will not be available if fuse test fails
|
|
or alarm is present. This test is intrusive and will
|
|
be available in shutdown state only."
|
|
::= { mltLoopLengthResultsEntry 1 }
|
|
|
|
mltLoopLengthLoopCapacitance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop length estimate will be based on tip-ring
|
|
capacitance measurement. User will be able to specify
|
|
the loop length multiplier. If not supplied, loop length
|
|
multiplier of 83 nF/ mile will be used. This test will
|
|
not be available if fuse test fails or alarm is present.
|
|
This test is intrusive and will be available in shutdown
|
|
state only. "
|
|
::= { mltLoopLengthResultsEntry 2 }
|
|
|
|
mltLoopLengthLoopLength OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "ft"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop length estimate will be based on tip-ring
|
|
capacitance measurement. User will be able to specify
|
|
the loop length multiplier. If not supplied, loop length
|
|
multiplier of 83 nF/ mile will be used. This test will
|
|
not be available if fuse test fails or alarm is present.
|
|
This test is intrusive and will be available in shutdown
|
|
state only. "
|
|
::= { mltLoopLengthResultsEntry 3 }
|
|
|
|
mltLoopLengthUncompensatedLoopCapacitance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "nF"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop length estimate will be based on tip-ring
|
|
capacitance measurement. User will be able to specify
|
|
the loop length multiplier. If not supplied, loop length
|
|
multiplier of 83 nF/ mile will be used. This test will
|
|
not be available if fuse test fails or alarm is present.
|
|
This test is intrusive and will be available in shutdown
|
|
state only. This value has no DSL correction."
|
|
::= { mltLoopLengthResultsEntry 4 }
|
|
|
|
mltLoopLengthUncompensatedLoopLength OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "ft"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loop length estimate will be based on tip-ring
|
|
capacitance measurement. User will be able to specify
|
|
the loop length multiplier. If not supplied, loop length
|
|
multiplier of 83 nF/ mile will be used. This test will
|
|
not be available if fuse test fails or alarm is present.
|
|
This test is intrusive and will be available in shutdown
|
|
state only. This value has no DSL correction."
|
|
::= { mltLoopLengthResultsEntry 5 }
|
|
|
|
|
|
mltLoopLengthErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates GNK and/or OTEMP alarms active when test was
|
|
run."
|
|
::= { mltLoopLengthResultsEntry 6 }
|
|
|
|
-- notifications
|
|
|
|
mltTestCompletedNotification NOTIFICATION-TYPE
|
|
OBJECTS { mltTestIdentifier, mltTestPort,
|
|
mltLastTestStatus, mltErrorText }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent to the
|
|
requesting host when the requested mlt
|
|
test has completed."
|
|
::= { mltTestNotifications 1 }
|
|
|
|
|
|
|
|
END
|