towerops/priv/mibs/calix/Axos-Card-MIB
Graham McIntire b4f8b40b7f
Include MIB files in Docker image instead of using PVC
- Remove PVC volume mount from k8s/deployment.yaml
- Delete k8s/mib-pvc.yaml (no longer needed)
- Update .gitignore to commit MIB files to git
- Add mix import_mibs task to copy MIBs from LibreNMS
- Add all MIB files from priv/mibs/ to git

This fixes the multi-attach volume error in Kubernetes where new pods
couldn't start because the RWO (ReadWriteOnce) PVC was attached to the
old pod. MIBs are now part of the Docker image and can be used by all
pods simultaneously.
2026-01-19 14:01:03 -06:00

301 lines
8.6 KiB
Text

Axos-Card-MIB DEFINITIONS ::= BEGIN
IMPORTS
Integer32,
Counter64,
IpAddress,
mib-2
FROM SNMPv2-SMI
DisplayString,
MacAddress
FROM SNMPv2-TC
axosModules
FROM CALIX-PRODUCT-MIB;
axosCardModule MODULE-IDENTITY
LAST-UPDATED "202010230000Z"
ORGANIZATION "Calix"
CONTACT-INFO
" Calix Networks, Inc.
Postal: 1035 North McDowell Boulevard
Petaluma, CA 94954-1173
USA
Phone: +1 707 766 3000
Fax: +1 707 766 3100
E-mail: mib-info@calix.com"
DESCRIPTION
"Describes card and OLT ODN port table for Calix Axos
based products"
REVISION "202010230000Z"
DESCRIPTION
"Initial revision"
::= { axosModules 4 }
-- Card Table
axosCardTable OBJECT-TYPE
SYNTAX SEQUENCE OF AxosCardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains Card entries"
::= { axosCardModule 1 }
axosCardEntry OBJECT-TYPE
SYNTAX AxosCardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "List of attributes related to Card"
INDEX { axosCardShelf, axosCardSlot }
::= { axosCardTable 1 }
AxosCardEntry ::= SEQUENCE {
axosCardShelf Integer32,
axosCardSlot Integer32,
axosCardAdminStatus INTEGER,
axosCardProvType INTEGER,
axosCardActualType INTEGER,
axosCardSoftwareVersion OCTET STRING,
axosCardSerialNumber DisplayString,
axosCardCurrentPowerLevel INTEGER,
axosCardCleiCode OCTET STRING,
axosCardPartNumber OCTET STRING,
axosCardStartMacRange OCTET STRING,
axosCardEndMacRange OCTET STRING,
}
axosCardShelf OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Shelf number"
::= { axosCardEntry 1 }
axosCardSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Slot number"
::= { axosCardEntry 2 }
axosCardAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
enabled(1),
alarmsuppress(2),
disabled(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Administrative status"
::= { axosCardEntry 3 }
axosCardProvType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
clx3001(1),
ng1601(2),
gp1601(3),
gp1611(4),
vdsl2r2(5),
ngpon2x4(6),
gpon8r2(7),
ge12(8),
ge24r2(9),
epon(10),
gpon(11),
eponmacsec(12),
e32ngpon(13),
asm3001(14),
gp1612(15),
xg801(16),
ce201(17),
e32xgs(18),
frwy(19),
xg3201(21),
asm5001(22),
xg1601(23)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Provisioned card type"
::= { axosCardEntry 4 }
axosCardActualType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
clx3001(1),
ng1601(2),
gp1601(3),
gp1611(4),
vdsl2r2(5),
ngpon2x4(6),
gpon8r2(7),
ge12(8),
ge24r2(9),
epon(10),
gpon(11),
eponmacsec(12),
e32ngpon(13),
asm3001(14),
gp1612(15),
xg801(16),
ce201(17),
e32xgs(18),
frwy(19),
xg3201(21),
asm5001(22),
xg1601(23)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Actual card type"
::= { axosCardEntry 5 }
axosCardSoftwareVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Running software version, dotted string notation"
::= { axosCardEntry 6 }
axosCardSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ascii Serial number for card"
::= { axosCardEntry 7 }
axosCardCurrentPowerLevel OBJECT-TYPE
SYNTAX INTEGER {
notSet(0),
powerLevelLow(1),
powerLevel2(2),
powerLevel3(3),
powerLevel4(4),
powerLevelFull(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current power level for card"
::= { axosCardEntry 8 }
axosCardCleiCode OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ascii CLEI code for card"
::= { axosCardEntry 9 }
axosCardPartNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ascii part number"
::= { axosCardEntry 10 }
axosCardStartMacRange OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Start of MAC range (ascii)"
::= { axosCardEntry 11 }
axosCardEndMacRange OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "End of MAC range (ascii)"
::= { axosCardEntry 12 }
-- Card ODN status
axosOltPonPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AxosOltPonPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains OLT ODN port entries"
::= { axosCardModule 2 }
axosOltPonPortEntry OBJECT-TYPE
SYNTAX AxosOltPonPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "List of attributes related to OLT ODN port"
INDEX { axosOltPonPortIfindex }
::= { axosOltPonPortTable 1 }
AxosOltPonPortEntry ::= SEQUENCE {
axosOltPonPortIfindex Integer32,
axosOltPonPortName OCTET STRING,
axosOltPonPortStatus INTEGER,
axosOltPonPortTemperature Integer32,
axosOltPonPortTxBias Integer32,
axosOltPonPortTxPower Integer32,
axosOltPonPortRxPower Integer32,
axosOltPonPortVoltage Integer32
}
axosOltPonPortIfindex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A unique value, greater than zero, for each interface. "
::= { axosOltPonPortEntry 1 }
axosOltPonPortName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual string containing information about the interface. "
::= { axosOltPonPortEntry 2 }
axosOltPonPortStatus OBJECT-TYPE
SYNTAX INTEGER {
invalid(0),
linkUp(1),
linkDown(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ODN-I operational status"
::= { axosOltPonPortEntry 3 }
axosOltPonPortTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ODN-I laser temperature ((value/1000)=degrees Celsius)"
::= { axosOltPonPortEntry 4 }
axosOltPonPortTxBias OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ODN-I laser bias current (muA) "
::= { axosOltPonPortEntry 5 }
axosOltPonPortTxPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ODN-I Tx signal level ((value / 10000) = mW) "
::= { axosOltPonPortEntry 6 }
axosOltPonPortRxPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ODN-I Rx signal level ((value / 10000) = mW) "
::= { axosOltPonPortEntry 7 }
axosOltPonPortVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ODN-I voltage in mV "
::= { axosOltPonPortEntry 8 }
END