- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
1282 lines
44 KiB
Text
1282 lines
44 KiB
Text
|
|
-- ============================================================================
|
|
-- AT-SYSINFO.MIB, Allied Telesis enterprise MIB:
|
|
-- Objects for system information
|
|
-- Copyright (c) 2006 by Allied Telesis, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- ============================================================================
|
|
|
|
AT-SYSINFO-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
atRouter, DisplayStringUnsized
|
|
FROM AT-SMI-MIB
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
sysinfo MODULE-IDENTITY
|
|
LAST-UPDATED "201612140000Z"
|
|
ORGANIZATION
|
|
"Allied Telesis, Inc."
|
|
CONTACT-INFO
|
|
" http://www.alliedtelesis.com"
|
|
DESCRIPTION
|
|
"Subtree beneath which system inforamtion ids are assigned.
|
|
It contains generic system information, as follows:
|
|
{ sysinfo 1 } fanAndPs
|
|
{ sysinfo 2 } restartGroup
|
|
{ sysinfo 3 } cpu
|
|
{ sysinfo 4 } sysTemperature
|
|
{ sysinfo 5 } atrContactDetails
|
|
{ sysinfo 6 } bbrNvs
|
|
{ sysinfo 9 } hostId
|
|
{ sysinfo 10 } envMon
|
|
{ sysinfo 11 } xem
|
|
{ sysinfo 12 } awpEnvMon
|
|
{ sysinfo 13 } awpStack
|
|
{ sysinfo 14 } atPortInfo"
|
|
|
|
REVISION "201612140000Z"
|
|
DESCRIPTION
|
|
"Added QSFP28-SR to atPortInfoTransceiverEntry"
|
|
REVISION "201612120000Z"
|
|
DESCRIPTION
|
|
"Added 10GBASE-ZR SFP+ to atPortInfoTransceiverEntry"
|
|
REVISION "201605050000Z"
|
|
DESCRIPTION
|
|
"Added 40GBASE-ER4 and 10GBBASE-T SFP+ to atPortInfoTransceiverEntry"
|
|
REVISION "201503160000Z"
|
|
DESCRIPTION
|
|
"Added 40GBASE-SR4 and 40GBASE-LR4 to atPortInfoTransceiverEntry"
|
|
REVISION "201406090000Z"
|
|
DESCRIPTION
|
|
"Added 4 x Cu Passive QSFP description to atPortInfoTransceiverEntry."
|
|
REVISION "201404300000Z"
|
|
DESCRIPTION
|
|
"Updated decriptions to refer to chassisMappingTable"
|
|
REVISION "201404160000Z"
|
|
DESCRIPTION
|
|
"Added more descriptions to cpuUtilisationStackId for VCStack Plus"
|
|
REVISION "201209210000Z"
|
|
DESCRIPTION
|
|
"Added chassis switch (e.g. SBx8100) descriptions to stack-related MIB objects"
|
|
REVISION "201103140000Z"
|
|
DESCRIPTION
|
|
"Added CX4 description to atPortInfoTransceiverEntry."
|
|
REVISION "201009180000Z"
|
|
DESCRIPTION
|
|
"Updated CPU Utilization to be per stack member."
|
|
REVISION "201009070000Z"
|
|
DESCRIPTION
|
|
"Generic syntax tidy up"
|
|
REVISION "201008310031Z"
|
|
DESCRIPTION
|
|
"Added Infinband descriptions to atPortInfoTransceiverEntry."
|
|
REVISION "201008160016Z"
|
|
DESCRIPTION
|
|
"Added SFP Plus descriptions to atPortInfoTransceiverEntry."
|
|
REVISION "201006150015Z"
|
|
DESCRIPTION
|
|
"MIB revision history dates in descriptions updated."
|
|
REVISION "201006040000Z"
|
|
DESCRIPTION
|
|
"Added new object atPortRenumberEvents."
|
|
REVISION "200802260000Z"
|
|
DESCRIPTION
|
|
"Changed top DESCRIPTION section."
|
|
REVISION "200606140000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { atRouter 3 }
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
-- fanAndPs traps - traps exist for changes to power supply status, fan status
|
|
-- and temperature status.
|
|
|
|
fanAndPs OBJECT IDENTIFIER ::= { sysinfo 1 }
|
|
|
|
|
|
fanAndPsTrap OBJECT IDENTIFIER ::= { fanAndPs 0 }
|
|
|
|
|
|
fanAndPsRpsConnectionTrap NOTIFICATION-TYPE
|
|
OBJECTS { fanAndPsRpsConnectionStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the RPS connection status changes."
|
|
::= { fanAndPsTrap 1 }
|
|
|
|
|
|
fanAndPsMainPSUStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { fanAndPsMainPSUStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the main power supply status changes."
|
|
::= { fanAndPsTrap 2 }
|
|
|
|
|
|
fanAndPsRedundantPSUStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { fanAndPsRedundantPSUStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the RPS status changes."
|
|
::= { fanAndPsTrap 3 }
|
|
|
|
|
|
fanAndPsMainFanStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { fanAndPsMainFanStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the main fan changes status."
|
|
::= { fanAndPsTrap 4 }
|
|
|
|
|
|
fanAndPsRedundantFanStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { fanAndPsRedundantFanStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the redundant fan changes status."
|
|
::= { fanAndPsTrap 5 }
|
|
|
|
|
|
fanAndPsTemperatureStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { fanAndPsTemperatureStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the temperature changes status."
|
|
::= { fanAndPsTrap 6 }
|
|
|
|
|
|
fanAndPsFanTrayPresentTrap NOTIFICATION-TYPE
|
|
OBJECTS { fanAndPsFanTrayPresent }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the fan tray presence status changes."
|
|
::= { fanAndPsTrap 7 }
|
|
|
|
|
|
fanAndPsFanTrayStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { fanAndPsFanTrayStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the fan tray status changes."
|
|
::= { fanAndPsTrap 8 }
|
|
|
|
|
|
fanAndPsMainMonitoringStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { fanAndPsMainMonitoringStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the main power supply monitoring status changes."
|
|
::= { fanAndPsTrap 9 }
|
|
|
|
|
|
fanAndPsAccelFanStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { fanAndPsAccelFanStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the accelerator fans' status changes."
|
|
::= { fanAndPsTrap 10 }
|
|
|
|
|
|
fanAndPsRpsConnectionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported(0),
|
|
connected(1),
|
|
notConnected(2),
|
|
notMonitoring(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the Redundant Power Supply (RPS) connection,
|
|
ie, whether an RPS is actually connected or not, regardless
|
|
of whether the RPS is on or not. notSupported means that an
|
|
RPS is not supported in this hardware platform, connected
|
|
means that the RPS is connected, notConnected means that the
|
|
RPS is not connected, and notMonitoring means that the status
|
|
of the RPS is not being monitored presently. RPS monitoring can
|
|
be turned on via the variable fanAndPsRpsMonitoringStatus, or
|
|
by the command SET SYSTEM RPSMONITOR=ON."
|
|
::= { fanAndPs 1 }
|
|
|
|
|
|
fanAndPsMainPSUStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
on(1),
|
|
off(2),
|
|
faulty(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the main Power Supply. on means that the power supply is present
|
|
and fully operational. off means that the power supply is totally off (and
|
|
obviously only applies to systems with a redundant power supply). faulty means
|
|
that the main power supply is delivering power but that a component of the
|
|
power supply is faulty. This applies to systems like SwitchBlade which have 3
|
|
power supplies but do not provide individual power supply monitoring. Also,
|
|
in the case of SwitchBlade, power supply status includes the status of the fans
|
|
in the power supply."
|
|
::= { fanAndPs 2 }
|
|
|
|
|
|
fanAndPsRedundantPSUStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported(0),
|
|
on(1),
|
|
off(2),
|
|
notMonitoring(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the redundant Power Supply. notSupported means
|
|
this device does not support redundant power supplies, on
|
|
means that the redundant power supply is connected and able
|
|
to supply system power if required, off means that the
|
|
redundant power supply is either not connected or is connected
|
|
and is not able to supply system power if required, and
|
|
notMonitoring means that the status of the RPS is not being
|
|
monitored presently. RPS monitoring can be turned on via the
|
|
variable fanAndPsRpsMonitoringStatus, or by the command
|
|
SET SYSTEM RPSMONITOR=ON."
|
|
::= { fanAndPs 3 }
|
|
|
|
|
|
fanAndPsRpsMonitoringStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported(0),
|
|
on(1),
|
|
off(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current status of redundant power supply monitoring. The
|
|
monitoring of the redundant power supply and its fan must be
|
|
enabled by command or by setting this variable to on. The value
|
|
notSupported means that this device does not support redundant
|
|
power supplies. Only the values on or off may be written to this
|
|
variable. If this variables reads as notSupported, an attempt to
|
|
write to this variable will result in a bad value error."
|
|
::= { fanAndPs 4 }
|
|
|
|
|
|
fanAndPsMainFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported(0),
|
|
ok(1),
|
|
notOk(2),
|
|
warning(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the main Power Supply fan. notSupported means that this
|
|
device does not support monitoring on the main power supply fan, or that
|
|
there is no main power supply fan. The warning means the fan's speed is
|
|
outside 30% of the expected speed."
|
|
::= { fanAndPs 5 }
|
|
|
|
|
|
fanAndPsRedundantFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported(0),
|
|
ok(1),
|
|
notOk(2),
|
|
notMonitoring(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the redundant Power Supply Fan. notSupported means
|
|
this device does not support redundant power supplies, ok
|
|
means that the redundant power supply fan is running, notOk means
|
|
that the redundant power supply fan is not running, and
|
|
notMonitoring means that the status of the RPS is not being
|
|
monitored presently. RPS monitoring can be turned on via the
|
|
variable fanAndPsRpsMonitoringStatus, or by the command
|
|
SET SYSTEM RPSMONITOR=ON."
|
|
::= { fanAndPs 6 }
|
|
|
|
|
|
fanAndPsTemperatureStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ok(1),
|
|
notOk(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of temperature in this device. ok means that the
|
|
device is not capable of monitoring temperature or that the
|
|
temperature is OK, notOk means that the temperature is being
|
|
monitored and is currently out of the range 0C - 45C."
|
|
::= { fanAndPs 7 }
|
|
|
|
|
|
fanAndPsFanTrayPresent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported(0),
|
|
present(1),
|
|
notPresent(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the presence of the fan tray in this system. Systems
|
|
which do not support a fan tray return the value notSupported. Upon
|
|
removal of the fan tray there is a short period (20s) before the value of
|
|
this variable is changed to notPresent. This is to allow for scheduled
|
|
replacement and/or cleaning of the fan tray."
|
|
::= { fanAndPs 8 }
|
|
|
|
|
|
fanAndPsFanTrayStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported(0),
|
|
ok(1),
|
|
notOk(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the fan tray in this system. Systems which do not support
|
|
a fan tray return the value notSupported. The value ok is returned if all fans
|
|
in the fan tray are running at full speed. The value notOk is returned if
|
|
one of more of the fan tray fans is running slow or has stalled."
|
|
::= { fanAndPs 9 }
|
|
|
|
|
|
fanAndPsMainMonitoringStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported(0),
|
|
ok(1),
|
|
notOk(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current status of main power supply monitoring. The
|
|
monitoring of the main power supply and its fan is always
|
|
enabled by those systems that support it. Systems which do
|
|
not support main power supply or fan monitoring report a
|
|
value of notSupported. The value ok is returned for those
|
|
systems that do support main power supply and fan monitoring,
|
|
and where the monitoring operation is reporting valid information (refer
|
|
to fanAndPsMainFanStatus for the current status of the system).
|
|
When main power supply and fan monitoring is failing, the value
|
|
notOk is returned."
|
|
::= { fanAndPs 10 }
|
|
|
|
-- fanAndPsPsuStatusTable - AT8948 specific power supply monitoring.
|
|
|
|
fanAndPsPsuStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FanAndPsPsuStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of AT8948 fanAndPsPsuStatusTable. Each entry in the table
|
|
represents the status of one of the power supplies in AT8948 system.
|
|
Each power supply has its own board ID."
|
|
::= { fanAndPs 11 }
|
|
|
|
|
|
fanAndPsPsuStatusEntry OBJECT-TYPE
|
|
SYNTAX FanAndPsPsuStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A single entry of AT8948 fanAndPsPsuStatusTable, indexed by
|
|
fanAndPsPsuNumber field."
|
|
INDEX { fanAndPsPsuNumber }
|
|
::= { fanAndPsPsuStatusTable 1 }
|
|
|
|
|
|
FanAndPsPsuStatusEntry ::=
|
|
SEQUENCE {
|
|
fanAndPsPsuNumber
|
|
INTEGER,
|
|
fanAndPsPsuPresent
|
|
INTEGER,
|
|
fanAndPsPsuType
|
|
INTEGER,
|
|
fanAndPsPsuFan
|
|
INTEGER,
|
|
fanAndPsPsuTemperature
|
|
INTEGER,
|
|
fanAndPsPsuPower
|
|
INTEGER
|
|
}
|
|
|
|
fanAndPsPsuNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PSU board identity for which this entry holds. If the system
|
|
consists only of a single PSU board, only one entry will appear
|
|
in the table, whose index is 1."
|
|
::= { fanAndPsPsuStatusEntry 1 }
|
|
|
|
|
|
fanAndPsPsuPresent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
yes(0),
|
|
no(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PSU present state, displayed as 'yes' if present, or 'no' if absent."
|
|
::= { fanAndPsPsuStatusEntry 2 }
|
|
|
|
|
|
fanAndPsPsuType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ac(0),
|
|
dc(1),
|
|
fan(2),
|
|
notPresent(3),
|
|
notSupported(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PSU type, displayed as AC, or DC, or FAN, or NOT PRESENT."
|
|
::= { fanAndPsPsuStatusEntry 3 }
|
|
|
|
|
|
fanAndPsPsuFan OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ok(0),
|
|
fail(1),
|
|
notPresent(2),
|
|
notSupported(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PSU fan status, displayed as OK, or FAIL, or NOT PRESENT."
|
|
::= { fanAndPsPsuStatusEntry 4 }
|
|
|
|
|
|
fanAndPsPsuTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
good(0),
|
|
high(1),
|
|
notPresent(2),
|
|
notSupported(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PSU temperature, displayed as GOOD, or HIGH, or NOT PRESENT,
|
|
or NOT SUPPORTED."
|
|
::= { fanAndPsPsuStatusEntry 5 }
|
|
|
|
|
|
fanAndPsPsuPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
good(0),
|
|
bad(1),
|
|
notPresent(2),
|
|
notSupported(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PSU power status, displayed as GOOD, or BAD, or NOT PRESENT
|
|
or NOT SUPPORTED."
|
|
::= { fanAndPsPsuStatusEntry 6 }
|
|
|
|
|
|
fanAndPsAccelFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported(0),
|
|
ok(1),
|
|
notOk(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the accelerator card fans. Non-supported means this
|
|
device does not support monitoring of the accelerator card fans."
|
|
::= { fanAndPs 12 }
|
|
|
|
|
|
restartGroup OBJECT IDENTIFIER ::= { sysinfo 2 }
|
|
|
|
|
|
restart OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
restartNone(0),
|
|
restartWarm(1),
|
|
restartCold(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A router/switch restart request.
|
|
|
|
A management station can remotely instruct an ATI router/switch
|
|
to action a warm or cold restart.
|
|
|
|
Once all the appropriate internal checks have been made, the
|
|
router/switch will acknowledge the request via normal SNMP channels.
|
|
The restart instruction will be actioned after waiting for a period
|
|
of 5 seconds, this is because the SNMP acknowledgement packet needs
|
|
time to reach the management station.
|
|
|
|
Once the request has been actioned, it can not be cancelled and
|
|
communication with the router/switch will be lost during system
|
|
initialisation."
|
|
::= { restartGroup 1 }
|
|
|
|
|
|
restartCause OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(0),
|
|
hardwareReset(1),
|
|
hardwareWatchdog(2),
|
|
softwareRequest(3),
|
|
softwareException(4),
|
|
softwareInvalidImage(5),
|
|
softwareLicenceCheckFailure(6),
|
|
powerOnSelfTestfailure(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reason for last time restart."
|
|
::= { restartGroup 2 }
|
|
|
|
|
|
restartLog OBJECT-TYPE
|
|
SYNTAX DisplayStringUnsized (SIZE (0..500))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The restart logging details."
|
|
::= { restartGroup 3 }
|
|
|
|
|
|
restartNotification NOTIFICATION-TYPE
|
|
OBJECTS { restartCause }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A restart notification is a trap sent to tell snmp managers
|
|
the reason of restarting"
|
|
::= { restartGroup 11 }
|
|
|
|
|
|
-- cpu - this group contains information about the cpu utilisation over different
|
|
-- periods of time.
|
|
cpu OBJECT IDENTIFIER ::= { sysinfo 3 }
|
|
|
|
|
|
cpuUtilisationMax OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum CPU utilisation since the router was last restarted.
|
|
Expressed as a percentage."
|
|
::= { cpu 1 }
|
|
|
|
|
|
cpuUtilisationAvg OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average CPU utilisation since the router was last restarted.
|
|
Expressed as a percentage."
|
|
::= { cpu 2 }
|
|
|
|
|
|
cpuUtilisationAvgLastMinute OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average CPU utilisation over the past minute.
|
|
Expressed as a percentage."
|
|
::= { cpu 3 }
|
|
|
|
|
|
cpuUtilisationAvgLast10Seconds OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average CPU utilisation over the past ten seconds.
|
|
Expressed as a percentage."
|
|
::= { cpu 4 }
|
|
|
|
|
|
cpuUtilisationAvgLastSecond OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average CPU utilisation over the past second.
|
|
Expressed as a percentage."
|
|
::= { cpu 5 }
|
|
|
|
|
|
cpuUtilisationMaxLast5Minutes OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum CPU utilisation over the last 5 minutes.
|
|
Expressed as a percentage."
|
|
::= { cpu 6 }
|
|
|
|
|
|
cpuUtilisationAvgLast5Minutes OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average CPU utilisation over the past 5 minutes.
|
|
Expressed as a percentage."
|
|
::= { cpu 7 }
|
|
|
|
cpuUtilisationStackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpuUtilisationStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of stack members. For a chassis switch, this is a list
|
|
of cards."
|
|
::= { cpu 8 }
|
|
|
|
cpuUtilisationStackEntry OBJECT-TYPE
|
|
SYNTAX CpuUtilisationStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of parameters that describe the CPU utilisation of a
|
|
stack member. For a chassis switch, it corresponds to the CPU
|
|
utilisation of a card."
|
|
INDEX { cpuUtilisationStackId }
|
|
::= { cpuUtilisationStackTable 1 }
|
|
|
|
CpuUtilisationStackEntry ::= SEQUENCE {
|
|
cpuUtilisationStackId
|
|
Unsigned32,
|
|
cpuUtilisationStackMax
|
|
INTEGER,
|
|
cpuUtilisationStackAvg
|
|
INTEGER,
|
|
cpuUtilisationStackAvgLastMinute
|
|
INTEGER,
|
|
cpuUtilisationStackAvgLast10Seconds
|
|
INTEGER,
|
|
cpuUtilisationStackAvgLastSecond
|
|
INTEGER,
|
|
cpuUtilisationStackMaxLast5Minutes
|
|
INTEGER,
|
|
cpuUtilisationStackAvgLast5Minutes
|
|
INTEGER
|
|
}
|
|
|
|
cpuUtilisationStackId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Stack member ID. For a chassis switch, it corresponds to the
|
|
card ID. For VCStack Plus, 1-12 refers to the cards on VCS stack
|
|
member 1 and 13-24 refers to the cards on VCS stack member 2.
|
|
Refer to chassisMappingTable for more details."
|
|
::= { cpuUtilisationStackEntry 1 }
|
|
|
|
cpuUtilisationStackMax OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum CPU utilisation since the router was last restarted.
|
|
Expressed as a percentage."
|
|
::= { cpuUtilisationStackEntry 2 }
|
|
|
|
cpuUtilisationStackAvg OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average CPU utilisation since the router was last restarted.
|
|
Expressed as a percentage."
|
|
::= { cpuUtilisationStackEntry 3 }
|
|
|
|
cpuUtilisationStackAvgLastMinute OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average CPU utilisation over the past minute.
|
|
Expressed as a percentage."
|
|
::= { cpuUtilisationStackEntry 4 }
|
|
|
|
cpuUtilisationStackAvgLast10Seconds OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average CPU utilisation over the past ten seconds.
|
|
Expressed as a percentage."
|
|
::= { cpuUtilisationStackEntry 5 }
|
|
|
|
cpuUtilisationStackAvgLastSecond OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average CPU utilisation over the past second.
|
|
Expressed as a percentage."
|
|
::= { cpuUtilisationStackEntry 6 }
|
|
|
|
cpuUtilisationStackMaxLast5Minutes OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum CPU utilisation over the last 5 minutes.
|
|
Expressed as a percentage."
|
|
::= { cpuUtilisationStackEntry 7 }
|
|
|
|
cpuUtilisationStackAvgLast5Minutes OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average CPU utilisation over the past 5 minutes.
|
|
Expressed as a percentage."
|
|
::= { cpuUtilisationStackEntry 8 }
|
|
|
|
|
|
|
|
|
|
-- sysTemperature - this group contains information about the temperature monitoring
|
|
-- in the system. under this group is a general group, containing generic temperature
|
|
-- monitoring variables, and one or more specific groups, which contain variables specific
|
|
-- to particular products.
|
|
|
|
sysTemperature OBJECT IDENTIFIER ::= { sysinfo 4 }
|
|
|
|
-- This group displays generic system temperature information - the actual
|
|
-- temperature, the fixed temperature threshold and an indication the
|
|
-- temperature has fallen below the threshold. A particular product may support
|
|
-- this information or not. If not the product may have a specific entry for
|
|
-- its particular temperature information. A product may also support the
|
|
-- generic information and additional specific information.
|
|
|
|
generalTemperature OBJECT IDENTIFIER ::= { sysTemperature 1 }
|
|
|
|
|
|
generalTemperatureTrap OBJECT IDENTIFIER ::= { generalTemperature 0 }
|
|
|
|
-- generalTemperature trap - a trap monitoring changes in the temperature status.
|
|
|
|
generalTemperatureStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { generalTemperatureStatus, generalTemperatureActualTemp, generalTemperatureThreshold }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the temperature status of the device changes."
|
|
::= { generalTemperatureTrap 1 }
|
|
|
|
|
|
generalTemperatureSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported(0),
|
|
supported(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value supported indicates general temperature is displayed by the
|
|
device. The value notSupported indicates the device displays specific
|
|
temperature information or none at all."
|
|
::= { generalTemperature 1 }
|
|
|
|
|
|
generalTemperatureActualTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current temperature of product's base board, in degrees Celsius. A device
|
|
which doesn't support this group will return the value 0 for this variable."
|
|
::= { generalTemperature 2 }
|
|
|
|
|
|
generalTemperatureStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ok(1),
|
|
notOk(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of temperature in this device. ok indicates the
|
|
temperature is below the threshold temperature or the device
|
|
is not capable of monitoring temperature. notOk indicates the
|
|
temperature is being monitored and is currently above the
|
|
threshold temperature (displayed in generalTemperatureThreshold)."
|
|
::= { generalTemperature 3 }
|
|
|
|
|
|
generalTemperatureThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature threshold for the device. If the
|
|
temperature of the device rises above this threshold
|
|
generalTemeratureStatus will indicate a notOk status."
|
|
::= { generalTemperature 4 }
|
|
|
|
|
|
-- sbTemperature - SwitchBlade specific temperature monitoring.
|
|
|
|
sbTemperature OBJECT IDENTIFIER ::= { sysTemperature 2 }
|
|
|
|
|
|
sbTemperatureTrap OBJECT IDENTIFIER ::= { sbTemperature 0 }
|
|
|
|
|
|
sbTempFixedThresholdTrap NOTIFICATION-TYPE
|
|
OBJECTS { sbTempFixedThresholdStatus, sbTempActualTemperature, sbTempFixedThreshold }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap occurs when fixed threshold status changes. The actual temperature
|
|
and the fixed threshold are also given."
|
|
::= { sbTemperatureTrap 1 }
|
|
|
|
|
|
sbTempSettableThresholdTrap NOTIFICATION-TYPE
|
|
OBJECTS { sbTempSettableThresholdStatus, sbTempActualTemperature, sbTempSettableThreshold }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap occurs when settable threshold status changes. The actual temperature
|
|
and the settable threshold are also given."
|
|
::= { sbTemperatureTrap 2 }
|
|
|
|
|
|
sbTempTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SbTempEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of SwitchBlade sysTemperature. Each entry in the table
|
|
represents temperature monitoring from one of the CPU cards which
|
|
may be present in the SwitchBlade system."
|
|
::= { sbTemperature 1 }
|
|
|
|
|
|
sbTempEntry OBJECT-TYPE
|
|
SYNTAX SbTempEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A single entry of SwitchBlade sysTemperature"
|
|
INDEX { sbTempIndex }
|
|
::= { sbTempTable 1 }
|
|
|
|
|
|
SbTempEntry ::=
|
|
SEQUENCE {
|
|
sbTempIndex
|
|
INTEGER,
|
|
sbTempActualTemperature
|
|
INTEGER,
|
|
sbTempFixedThresholdStatus
|
|
INTEGER,
|
|
sbTempSettableThresholdStatus
|
|
INTEGER,
|
|
sbTempSettableThreshold
|
|
INTEGER
|
|
}
|
|
|
|
sbTempIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
master(1),
|
|
slave(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The board for which this temperature entry holds. If the system
|
|
consists only of a single CPU board, only one entry will appear
|
|
in the table, whose index is master(1)."
|
|
::= { sbTempEntry 1 }
|
|
|
|
|
|
sbTempActualTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual SwitchBlade temperature. This temperature is measured
|
|
within the SwitchBlade CPU, and is sampled at 1 second intervals."
|
|
::= { sbTempEntry 2 }
|
|
|
|
|
|
sbTempFixedThresholdStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1),
|
|
crossover(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature status with regard to the fixed temperature
|
|
threshold. The value of the fixed temperature threshold is set at
|
|
90 degrees C. This variable represents whether the actual temperature
|
|
is above the threshold (value is crossover(2)) or below the threshold
|
|
(value is normal(1)). If the temperature is exactly the same as the
|
|
fixed temperature threshold, the value of this variable reads as
|
|
normal(1)."
|
|
::= { sbTempEntry 3 }
|
|
|
|
|
|
sbTempSettableThresholdStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1),
|
|
crossover(2),
|
|
undefined(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature status with regard to the settable temperature
|
|
threshold. The value of the settable temperature threshold is set by
|
|
management intervention. This variable represents whether the actual
|
|
temperature is above the threshold (value is crossover(2)) or below
|
|
the threshold (value is normal(1)). When the value of this variable is
|
|
undefined(3), no settable threshold has been specified and the value
|
|
of sbTempSettableThreshold is not used."
|
|
::= { sbTempEntry 4 }
|
|
|
|
|
|
sbTempSettableThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (30..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the settable temperature threshold. This can be set
|
|
independently for each temperature entry. The value of this threshold
|
|
is only valid when sbTempSettableThresholdStatus is not set to
|
|
undefined(3)."
|
|
::= { sbTempEntry 5 }
|
|
|
|
|
|
sbTempFixedThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the fixed temperature threshold. This value is fixed for
|
|
both CPU cards, and cannot be set."
|
|
::= { sbTemperature 2 }
|
|
|
|
|
|
-- acceleratorTemperature - Accelerator card specific temperature monitoring.
|
|
|
|
acceleratorTemperature OBJECT IDENTIFIER ::= { sysTemperature 3 }
|
|
|
|
|
|
acceleratorTemperatureTrap OBJECT IDENTIFIER ::= { acceleratorTemperature 0 }
|
|
|
|
|
|
acceleratorTemperatureStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { acceleratorTemperatureStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the temperature status of the device changes."
|
|
::= { acceleratorTemperatureTrap 1 }
|
|
|
|
|
|
acceleratorTemperatureSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported(0),
|
|
supported(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value supported indicates whether accelerator card temperature
|
|
is displayed by the device. The value notSupported indicates the
|
|
device does not display specific accelerator card temperature
|
|
information."
|
|
::= { acceleratorTemperature 1 }
|
|
|
|
|
|
acceleratorTemperatureActualTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current temperature of product's base board, in degrees Celsius. A device
|
|
which doesn't support this group will return the value 0 for this variable."
|
|
::= { acceleratorTemperature 2 }
|
|
|
|
|
|
acceleratorTemperatureStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ok(1),
|
|
notOk(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of temperature in this device. ok indicates the
|
|
temperature is below the threshold temperature or the device
|
|
is not capable of monitoring temperature. notOk indicates the
|
|
temperature is being monitored and is currently above the
|
|
threshold temperature (displayed in generalTemperatureThreshold)."
|
|
::= { acceleratorTemperature 3 }
|
|
|
|
|
|
acceleratorTemperatureThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature threshold for the device. If the
|
|
temperature of the device rises above this threshold
|
|
generalTemeratureStatus will indicate a notOk status."
|
|
::= { acceleratorTemperature 4 }
|
|
|
|
-- acceleratorTemperature trap - a trap monitoring changes in the temperature status.
|
|
|
|
atContactDetails OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The contact details for Allied Telesis inc."
|
|
::= { sysinfo 5 }
|
|
|
|
-- bbrNvs - this group contains information about the battery backed RAM non-volatile storage
|
|
-- in the router.
|
|
|
|
bbrNvs OBJECT IDENTIFIER ::= { sysinfo 6 }
|
|
|
|
|
|
bbrNvsTrap OBJECT IDENTIFIER ::= { bbrNvs 0 }
|
|
|
|
|
|
bbrNvsReinitialiseTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated at boot when the device detects that the BBR has been
|
|
corrupted and reinitialised. This can happen if the device's BBR
|
|
battery has run down, and the device has been powered off, then on."
|
|
::= { bbrNvsTrap 1 }
|
|
|
|
|
|
-- memory - this group contains information about the current memory status
|
|
-- of the router.
|
|
memory OBJECT IDENTIFIER ::= { sysinfo 7 }
|
|
|
|
|
|
freeMemory OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Percentage of free memory still available on device"
|
|
::= { memory 1 }
|
|
|
|
|
|
totalBuffers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of buffers available on device"
|
|
::= { memory 2 }
|
|
|
|
|
|
lowMemoryTrap NOTIFICATION-TYPE
|
|
OBJECTS { freeMemory, totalBuffers }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A low memory trap is generated when a router's memory
|
|
has gone below a certain level."
|
|
::= { memory 11 }
|
|
|
|
|
|
realTimeClockStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
invalid(0),
|
|
normal(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shows the status of the real time clock"
|
|
::= { sysinfo 8 }
|
|
|
|
|
|
hostId OBJECT-TYPE
|
|
SYNTAX INTEGER (0..32)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Host Identifier of this device"
|
|
::= { sysinfo 9 }
|
|
|
|
|
|
atPortInfo OBJECT IDENTIFIER ::= { sysinfo 14 }
|
|
|
|
|
|
atPortInfoTransceiverTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtPortInfoTransceiverEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of information about the transceiver of a interface."
|
|
::= { atPortInfo 1 }
|
|
|
|
|
|
atPortInfoTransceiverEntry OBJECT-TYPE
|
|
SYNTAX AtPortInfoTransceiverEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description, the transceiver type of a interface."
|
|
INDEX { atPortInfoTransceiverifIndex }
|
|
::= { atPortInfoTransceiverTable 1 }
|
|
|
|
|
|
AtPortInfoTransceiverEntry ::=
|
|
SEQUENCE {
|
|
atPortInfoTransceiverifIndex
|
|
InterfaceIndex,
|
|
atPortInfoTransceiverType
|
|
INTEGER
|
|
}
|
|
|
|
atPortInfoTransceiverifIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex for the interface represented
|
|
by this entry of the interfaces table."
|
|
::= { atPortInfoTransceiverEntry 1 }
|
|
|
|
|
|
atPortInfoTransceiverType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rj45(1),
|
|
sfp-px(2),
|
|
sfp-bx10(3),
|
|
sfp-fx(4),
|
|
sfp-100base-lx(5),
|
|
sfp-t(6),
|
|
sfp-cx(7),
|
|
sfp-zx-cwdm(8),
|
|
sfp-lx(9),
|
|
sfp-sx(10),
|
|
sfp-oc3-lr(11),
|
|
sfp-oc3-ir(12),
|
|
sfp-oc3-mm(13),
|
|
xfp-srsw(14),
|
|
xfp-lrlw(15),
|
|
xfp-erew(16),
|
|
xfp-sr(17),
|
|
xfp-lr(18),
|
|
xfp-er(19),
|
|
xfp-lrm(20),
|
|
xfp-sw(21),
|
|
xfp-lw(22),
|
|
xfp-ew(23),
|
|
unknown(24),
|
|
empty(25),
|
|
sfpp-sr(26),
|
|
sfpp-lr(27),
|
|
sfpp-er(28),
|
|
sfpp-lrm(29),
|
|
inf-1-x-copper-pasv(30),
|
|
inf-1-x-copper-actv(31),
|
|
inf-1-x-lx(32),
|
|
inf-1-x-sx(33),
|
|
cx4(34),
|
|
inf-4-x-copper-pasv(35),
|
|
qsfp-sr(36),
|
|
qsfp-lr(37),
|
|
qsfp-er(38),
|
|
sfpp-t(39),
|
|
sfpp-zr(40),
|
|
qsfp28-sr(41)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the type of transceiver on a interface."
|
|
::= { atPortInfoTransceiverEntry 2 }
|
|
|
|
|
|
atPortRenumberEvents OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that port number values (represented by the
|
|
dot1dBasePort object in BRIDGE-MIB), have been re-assigned due to
|
|
stack member leave/join events or XEM hot-swap events, since the
|
|
system was initialised."
|
|
::= { atPortInfo 2 }
|
|
|
|
|
|
|
|
END
|
|
|
|
--
|
|